Loading...
2014-057 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140057 Date Issued: Friday, April 10, 2015 This is to certify that work requested to be done as shown by Permit Number P20140057 has been completed. Location: 216 Queensbury Ave Tax Map Number: 523400-303-008-0001-013-002-0000 Owner: CRAIG BROWN Applicant: CRAIG BROWN This structure may be occupied as a: Apartments By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the propertyr:D �r1tf'/n Aa owner of the responsibility for compliance with Site Plan,Variance, or `i_ �VJ other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY `oiro 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140057 Application Number: A20140057 Tax Map No: 523400-303-008-0001-013-002-0000 Permission is hereby granted to: CRAIG BROWN For property located at: 210 Queensbury Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CRAIG BROWN Apartments 214 QUEENSBURY Ave P $372,000.00 QUEENSBURY,NY 12804-0000 Total Value $372,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency CRAIG BROWN 214 OUEENSBURY Ave OUEENSBURY.NY 12804-0000 Plans&Specifications 2014-057 MULTI FAMILY 4-unit apartment 1st Flr 3,170; 2nd flr 1,145 sq ft $863.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, March 14,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To nsbu A Fry+yJ arch 14, 2014 Ar/� SIGNED BY for the Town of Queensbury. Director of Building& Code Enforcement • .t Office Use Only Town of Queensbury Building & Codes Received: Tax Map ID: !ib ' ' n PRINCIPAL STRUCTURE APPLICATION Permit No.: —v A permit must be obtained before beginning construction Permit Fee: $ i (0 3 Please read: 'T8 resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling *Rec Fee: $ UD units, including single-family dwellings,duplexes or two-family dwellings, multiple family Site Plan No.: dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.: homes,but not including mobile homes.�nThis is in addition to the permit fee. Date SI Mid !i Applicant owner Tax Map ID 3b,.a -1- 13. 2_ Address Zoning Nerjhk/o,rhood £Csidm f r r1 - AIR /1 Phone/E-mail Property Owner (rot UI'bwn Contractor/Agent Owtlt'V Address 2!y J a✓Gnus- q A-ft- Address @tl beV 'v ! V. 171A91/Phone/E-mail V Q C' I Phone/E-mail Contact Person for Building &Code Compliance: (Mc) hti Day Phone: W-024$ '1 'IJQ Q✓G{s1s6dM Ai/C 111-6.31qBuilding Street Address: Subdivision Name: Jj(_ IV!T ?/114(q &IVWn Lot#: OA tT- Historic Site: _Yes kNo Estimated cost of construction: $ 372/x00 / fl Type of Construction: Check all that apply Please indicate measurements as required below: c o m 1st Floor 2nd Floor Other Total Height ? a a Single Family Two-Family . _ . . Multi-F ily(#of units 9) ✓ �J170 II (-IC 1112 C ? �a Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garages(#_) Other Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Please include two (2) sets of the following documentation with the submission of a Completed application for a Building&Zoning Permit 1. Principal Structure Application 2. Plot plan drawn to scale with the use of a survey map, if possible [40 scale-1 inch=40 feet[engineering scale]: , i • Indicate proposed structure, showing setback dimensions from all surveyed property lines • Show location of all existing structures on the property v • Show location of water supply(well or water lines) ✓ • Show location and configuration of septic disposal system or sewer line V 3. Structural Drawings to include: ✓ • Floor Plan • Foundation Plan ./ • Cross Sections f • Elevations • Window and Door Schedule—see attachment • Calculation Sheet for Natural Light, Ventilation&Emergency Egress—see attachment 4. Registered Architect or Engineer's Stamp(signed &sealed) under the following circumstances:r/ • Residential addition or alterations with construction costs over$20,000 • Single Family Dwelling 1,500 sq. ft.or greater • Any commercial construction 5. Checklist for single family or multiple dwelling or commercial project 6. REScheck orCOMcheck signed &stamped: Downloadable version-www.energycodes.gov. 7. Fireplace and/or woodstove solid fuel burning application (if applicable) Nd- 8. Septic Disposal Permit(if applicable) ✓ 9. Electrical Inspection Agency- Please see"Certified Electrical Form"on the Town's website Coni'" - 1 10. Driveway permit(if applicable) f,/Ar 11. Fee Notes: Certificate of Occupancy: Before a certificate of occupancy is issued for a new residential or commercial structure, an as- built survey[plot plan]certified NYS licensed surveyor must be filed with our office. Changes to Plan: Any changes prior to or during construction will require submittal of amended plans[review and re- approval are necessary]. Withdrawn Permits: 20%of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. Additional Review: All Applications are subject to Zoning Administrator, Code Compliance, and Structural plan review Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Checklist - Single family dwelling or Multiple dwelling / Commercial project SINGLE FAMILY DWELLING PROJECT CHECKLIST PROJECT NAME: Please include two(2)sets of the following documentation: Yes No NIA 1. Building Permit Application Completed 2. Energy Code Inspectors Report from ResCheck 3. Septic application (if applicable) 4. Solid Fuel Burning or Gas Appliance Form(if applicable) 5. Driveway Permit 6. Structural Drawings Floor plan(s) Foundation plan Cross Sections Elevations Window and door schedule Natural Light,Ventilation and Emergency Egress Requirements Plans signed and sealed by registered architect or engineer 7. Plot Plans- Indicate proposed structure,showing setback dimensions from all surveyed property lines; Show location of all existing structures on the property; Show location of water supply(well or water lines); Show location and configuration of septic disposal system or sewer line 8. Electrical Inspection agency selected MULTIPLE DWELLING OR COMMERCIAL PROJECT CHECKLIST PROJECT NAME: Please include two(2)sets of the following documentation: Yes No NIA 1. Building Permit Application Completed V 2. Energy Code ComCheck and Inspectors Report Form 3. Septic application completely filled out(if applicable) 4. Solid Fuel Burning or Gas Appliance Form(if applicable) 1/ 5. Driveway Permit ✓ 6. Structural Drawings Floor plan(s) Foundation plan Cross Sections Elevations Design loads including floor,snow load and wind load Seismic design(required after January 2003) Plans signed and sealed by registered architect or engineer Window and door schedule 7. Plot plan: Indicate proposed structure,showing setback dimensions from all surveyed property lines Show location of all existing structures on the property Show location of water supply(well or water lines) Show location and configuration of septic disposal system or sewer line 8. Electrical inspection agency selected Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Office Use Only Town of Queensbury Building & Codes Received: Tax Map ID: FUEL BURNING APPLIANCE & CHIMNEY APPLICATI ermit No.: Permit Fee: $ Application is hereby made to,t uilding &Codes Office for the issuance of a Building & Use Pe • tt pursuant to the NYS Fire Prevention & Building Code. The a;�p' ant or owner agrees to comply with all applicable laws, ordinances, r=.ulations, and all conditions that are part of these requirementsrind also will allow all inspectors to enter premises to perform required insp- tions. Important ote To Applicant: Rouqh-In and Final Inspections Are Required: Date Owner Install: /Builder Address Add -ss Phone "hone Location of proposed construction end/or installation: Contact Person for Building &Codes C.r pliance: Subdivision Name: Fuel Burning Appliance Information W. Coal Pellet Gas Oil Stove Fireplace Insert Fireplace,factory built* Fireplace, Masonry Furnace, (Garage Only) * If Factory Built, Please Provide: Ma facturer Name: '.del No. Listed By: Number: Chimney Information Masonry" "check one /Block Brick _Stone Flue ✓check one _Tile Steel _Size in Inches Material ✓check one _Double Wall _Triple Wall _Insulated Direct Vent _Chimney Liner ** If Non-Masonry, ple se provide: Manufacturer Name: Model No. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION & BUILD G CODE AND/OR MANUFACTURER R QUIREMENTS. CONSULT AVAILABLE Town of Queensbury HANDOUTS REGARDING REQUIR e NSPECTIONS. Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 • Office Use Only Received: Tax Map ID: Town of Queensbury Building & Codes Permit No.: SEPTIC DISPOSAL PERMIT Permit Fee: $ A permit must be obtained before beginning construction Approvals: Applicant: C•�Q r� i; `^ Installer/Builder 1-19 fl.lt4m5&s Art Address QoccMt,� iwiva`1 Phone: Phone �1 Owner: 470yn4 Location of Installation 'lite QUe.ewsbv' kr- Address: Phone QQ., Contact Person for Building&Code Compliance: vVG1(E PribW to Day Phone: Residence Information: Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow 1980 or older x 150 = Garbage Grinder installed? 1981-1991 x 130 = Spa or Hot Tub Installed? 1992-Present x 110 = 060 Parcel Information: Topography /Flat Rolling _Steep Slope %Slope Soil Nature Sand ✓Loam _Clay _Other Groundwater At what depth? 5' 4 BedrocIdImpervious Material At what depth? Domestic Water Supply ;Municipal Well(if well,water supply from any septic system absorption is ft.) Percolation Test Rate- per minute per inch(Test to be completed by a licensed professional engineer or architect) 3•3b/ 1 Nr/v t Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). CTank size 2/ gallon(minimum size 1,000 gallons), add 250 gallons to size of septic tank for each garbage grinder,spa or whirlpool tub rr System Type: Absorption Field(with#2 stone) Total length t 0 ft. Each trench Z x 7�r Seepage Pit(S)(with#3 stone) How many? Size? Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size? #of tanks? NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified Electrical form on Town website;2)Effective as of March 23,2006 Septic System-As Built Plot Plan: The Building Department will no longer allow systems to be covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed system must match the septic system layout on file. There will be no exceptions. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. ✓I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Print Name: Cr41 6YDDate: 10 IMw� { Signature: � u.✓\ Date: 1,0 y,I G✓ i Town of Queensbury Building Codes Principal Structure Packet 518-7611256 Town of Queensbury Highway Department DRIVEWAY PERMIT Michael F. Travis, Highway Superintendent Thomas R. Van Ness, Deputy Superintendent Home: (518)798-0413 Home: (518)745-0929 Office Phone: (518)761-8211 Office: (518)761-8211 Fax: (518) 745-4466 Building Permit#: ���V Date: Tax Map ID: Applicant Name: Address to be inspected: Return Address: Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: Step 1: ( )Preliminary Approval Need: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( )24" ( )36° Preliminary inspections completed by: Date: Approved by Highway Supt: Deputy Supt.: Upon completion, please resubmit this approved permit for a final approval. Step 2: ( ) Final Approval ( ) Rejected Date: Michael F. Travis, Highway Superintendent Thomas R. Van Ness, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 WINDOW SCHEDULE CALCULATION SHEET JOB SITE ADDRESS: DATE: 5-66 OWNER: �IS APPLICATION NO.: Window#or Letter Window Manuf. Window Unit or Stock# Rough Rough Sq.Ft.Vent Sq.ft.egress 1 Clear opening Clear opening Special hardware or on Plan Name Model Type Call size Opening Width Opening clear opening width in inches height in instructions Height inches Town of Queensbury Building 8 Codes Principal Structure Packet 518-761-8256 NATURAL LIGHT, VENTILATION, AND EMERGENCY EGRESS REQUIREMENTS CALCULATION SHEET JOB SITE ADDRESS: DATE: C i/" C J OWNER: a)-(-1- APPLICATION NO.: NATURAL LIGHT, VENTILATION, AND EMERGENCY EGRESS REQUIREMENTS Habitable Room Area of Room Required light Actual light square footage Required ventilation Actual Ventilation Square Footage Square Foot Opening for Egress Remarks In Square Feet 8%of room area 4%of room area Town of Queensbury Building 8 Codes Principal Structure Packet 518-761-8256 Amanda's Law Requirements Carbon Monoxide Alarms in Single Family Homes Single family homes constructed after December 31, 2007 • Within each bedroom or sleeping area • On each story outside the bedroom or sleeping area • On each level containing a Carbon Monoxide Source The term "carbon monoxide source"includes fuel fired appliances, equipment, devices and systems; solid fuel burning appliances, equipment, devices and systems; all other appliances, equipment, devices and systems that may emit carbon monoxide;fireplaces;garages;and all other motor vehicle-related occupancies. In Single Family Homes constructed prior to January 1, 2008 the Carbon Monoxide Detector may be hard wired or battery operated where no interconnection is possible due to existing wiring. Amanda's Law Requirements Carbon Monoxide Alarms in Buildings with 3 or More Dwelling Units Buildings constructed prior to January 1,2008 • On the lowest floor level containing a bedroom or sleeping area Buildings constructed after December 31,2007 • On each story outside the bedroom or sleeping area • On each level containing a Carbon Monoxide Source • Any construction that involves the construction of a chimney or attached garage The term °carbon monoxide source" includes fuel fired appliances, equipment, devices and systems; solid fuel burning appliances, equipment, devices and systems; all other appliances, equipment, devices and systems that emit carbon monoxide; fireplaces;garages; and all other motor vehicle-related occupancies. In buildings constructed prior to January 1, 2008 the Carbon Monoxide Detector may be hard wired or battery operated where no interconnection is possible due to existing wiring. Non-compliance will be dealt with when a complaint is filed with the Building and Codes Department (761-8256) or the Fire Marshal's office (761-8206). Batteries need to be replaced every year. It is recommended CO Detectors be replaced every 5 years. DO NOT RUN VEHICLES, GENERATORS, GAS GRILLS OR OTHER GASOLINE POWERED EQUIPMENT IN YOUR GARAGE. Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 New Changes to Residential Building Code effective January 1, 2011 New driveway requirements for structures located over 300 feet from main road Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas Protection against decay requirements (see attached) Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements Arc fault breakers required in all habitable spaces for receptacles. GFI protection for all other receptacles in kitchens, bathrooms, garages, and unfinished basements All receptacles must be tamper resistant Carbon Monoxide detectors must be located within 15 feet of sleeping area All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code Requirements Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant Programmable thermostats required Lighting must be 50% energy saving light bulbs Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit Res Check inspector's checklist must be available at time of insulation inspection Tovm of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Queensbury Building & Code Enforcement - Residential Final Inspection i�-1 L ,a Office No. (518) 761-8256 G V� ,� Arrive: am/pm Depart: I I ` m/pm Date Inspection request received: ill-1 Inspector's Y Initials: '�,�(( NAME: bw . n PERMIT#: '4-113 -1- LOCATION: 2- LOCATION: 2110 QnSbv vti DATE: E[`\o l 2O t 5 TYPE OF STRUCTURE: MU.\-t-*- f CAVvn'& It Comments: Ye$/ No N/A_ 4" Building Number Address visible from road \/` �7 rn spit u\ s CIS.Height/"B"Vent/Direct Vent Location V/ L Fresh Air Intake V 3 inch Plumbing Vent through roof minimum 18 inches ✓ .Roof Complete/Exterior Finish Complete t// Platform at more risdoors ✓f P4444-3%)1Z-(4-)-C-1-b. �,4 �y )-,-,Qa j e Handrail 4 or more risers oy/ ,/J �F - �.,,, ' p Guards at stairs,decks,patios more than 30 inches above grade 118 W�t1 ^ Guard at stairwell at 34 Inches or more ✓� uard at deck, porches 36 inches or mo andrall Termination at Newell Post all Interior/Exterior Railings 34 inches to 3 i6inches if / Deck Bracing/Handicapped Ramp Compliant V Grade away from foundation 6 inches with 10 feet S Z�1-011 '-!f. -. )`lr�) 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches 1 Bathroom/Kitchen watertight / _ _ Safety glazing/Wi in stairwells safety gl ng t/ Interior Smoke D ectors!Carbon Monoxi Detectors Every level: Eve Bedrokyfi: _ / Outside every bedroom ea: ✓ ✓/ Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft-150 sq.ft.vents Bathroom Fans,if no window V Plumbing fixtures /`/, Foundation insulation to floor!Sticker on Panel 1 C7:1 Duct work sealed properly/Blower Door Test Certification Floor truss, draft stopping finished basement 1,000 sq.ft V."Emergency egress below grade / Gas Furnace shut-off within 30 feet or within line of site �/ Oil Furnace shut-off at entrance to furnace area / Fumace/Hot Water Heater operating 1/ Low water shut-off boler v/ Relief Valve(s)installed/Heat Trap/Water Temp 110 !// Enclosed Stairs Sheetrock Underside minimum W Gypsum v" Basement stairs dosed rise>4 inches Garage Floor Pitched ✓/ Garage fireproofing 1'%hour fire door/door closer Vj Gas Logs in Sealed or Glass Enclosure V Final Electrical;Energy Saving Light Bulbs 50% f//�/ Final Survey Plot Plan Arc Fault Breaker Habitable Spaces!Tamper Proof Receptacles Flex Gas Pipe Bonding / J f/ As Built Septic System/Sewer Dept. Inspection Sticker / Site Plann Variance required `/ d FlooddCertification,PlainCertficetion,if required (l Okay to issue C/C or Cl 0[Temporary/Permanent] \ r lissDS t�ncise acts or newQr L:\Building &Codes Forns\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7, 2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 Town of Queensbury Building &Code Enforcement Office No. (518)761-8256 Septic Inspection Report Inspection request received: Name: l f April in Inspected on: t i hp°t c Location: b A- a Arrive: a - /► a.m./p.m. Permit No.: / 49—b S7_ Inspector's Initials: —i, .'I� Comments and/. diagram Soil Type Sand/Loam 1 Clay Type of Water: Municipal 1 Well Water Waterline separation distance A ft. Well separation distance ft. Other wells. ft. Well Casing Length 50'+/- Y N N/A [150'to well required if NO] Absorption Field. Total length Length of each trench ft Depth of trenches ft Size of Stone Seepage Pits: Number Size. Stone Size: 1?7 :_tiV Piping Size Type (— Tanking to tank 13.-A-51/ '—`A I /� Tank to Distribution Bo �! � Distribution Box to Fief]/Pit Opening Sealed. _Y End Cap Inlet/Outlet Pipes&B.files Y N Manholes 12"or less n elow grade Y N [provide extension col.r if Yes] Y N Location/Separation• Foundation to tank ft. Foundation to absorpti'n ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N ETU Maintenance Contract provided Y N Location of System on Property: Front R:.r Left Side Right Side Middle Front Middle Rear S stem Use Sta : . -♦ Appr. -I •artial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Septic Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8258 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: r�'4r am/pm �+ 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 4 U NAME: (V, PERMIT t. A 5 d IF LOCATION: 2x(e INSPECT ON: I. Er TYPE OF STRUCTURE: AN5 Y N N/A Rough Plumbing/ Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch mi imum Cleanout every 100 feet 1 change •f directio Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft above highest ?• echo/ for ' 5 minutes , Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/ om ercial Check Tyvek or Similar Exterior Sealan Proper Vent, Attic Vent Door/Window Sealed (No Insu bon) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: - ' ft r Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 20 /V- o57 1 i ' �V 2014 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 11/17/2014 Mr. Craig Brown, Director, Planning/Zoning Town of Queensbury 742 Bay Road Queensbury, NY 12804 Inspection Address: 216A�Queensbury Avenue, Queensbury NY 12804 Report Number: 1117141 Dear Craig: At your request, the Blower Door Inspection of the post construction test to verify infiltration rate of the apartment as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property was performed on 11/17/2014. GRAINY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment=965 SF - Volume of the apartment=7,720 CF Based on above, the following test data was collected: - Infiltration Rate at 50 Pascal = 670 CFM - ACHSO, Actual Changes per Hour at 50 Pascal=670X60/7,720 lUif, 7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%, calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. • Sincerely, % ldElPp:: •{ 1/4„n}: Stan Grajny, PE •-• Q NYS HERS Energy Rater BER-04l •'• 71`1141"r' .� NYS PE 065406-1 `.:Peoo tU4 os „T GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 11/17/2014 Mr. Craig Brown, Director, Planning/Zoning Town of Queensbury 742 Bay Road Queensbury,NY 12804 Inspection Address: 21 B6 Queensbury Avenue, Queensbury NY 12804 Report Number: 1117142 Dear Craig: At your request, the Blower Door Inspection of the post construction test to verify infiltration rate of the apartment as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property was performed on 11/17/2014. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment= 1,054 SF - Volume of the apartment=8,432 CF Based on above, the following test data was collected: - Infiltration Rate at 50 Pascal =909 CFM - ACH50, Actual Changes per Hour at 50 Pascal =909X60/8,432 =6S < 7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%, calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. ttef NEWy . Sincerely, 5� 0AUSGa �'Qr te a Stan Grajny, PE frr^,,, NYS HERS Energy Rater BER-041 "'""''~ C��r" NYS PE 065406-1 FO 5540 . 4C GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 11/17/2014 Mr. Craig Brown, Director, Planning/Zoning Town of Queensbury- 742 Bay Road Queensbury,NY 12804 Inspection Address. 216C,Queensbury Avenue, Queensbury NY 12804 Report Number: 1117143 Dear Craig: At your request, the Blower Door Inspection of the post construction test to verify infiltration rate of the apartment as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property was performed on 11/17/2014. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment= 1,054 SF - Volume of the apartment=8,432 CF Based on above,the following test data was collected: - Infiltration Rate at 50 Pascal =937 CFM - ACH50, Actual Changes per Hour at 50 Pascal =937X60/8,432--6�.7;.<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%, calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. . 4' .SAtSEP✓r04 Sinecrely, osW� ` ("AA :is,. • ,! c Stan Grajny, PE NYS HERS Energy Rater BER-04l Fp 065405 ort NYS PE 065406-1 ESSI0,,\' GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 11/17/2014 Mr. Craig Brown, Director, Planning/Zoning Town of Queensbury 742 Bay Road Queensbury,NY 12804 Inspection Address: 2169 Queensbury Avenue, Queensbury NY 12804 Report Number: 1117144 Dear Craig: At your request, the Blower Door Inspection of the post construction test to verify infiltration rate of the apartment as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property was performed on 11/17/2014. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment=965 SF - Volume of the apartment= 7,720 CF Based on above,the following test data was collected: - Infiltration Rate at 50 Pascal =641 CFM - ACH50, Actual Changes per Hour at 50 Pascal =641X60/7.7200;<7. The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy= 1%, calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, �PSt NEW UkUS k. tt- 43-1 Stan Grajny, E z.v NYS HERS Energy Rater BER-041 u+ NYS PE 065406-1e : ,ec6S408 vhEss.÷ 1p‘ WS 5K—/e) Multiple Dwelling, Hotel, Motel, Apartment Final Inspection Report Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. 40:4sm 742 Bay Road,Queensbury, NY 12804 Inspector's Initial / NAME: c a ratio n PERMIT#: / (1-08) LOCATION: 0 b, Pve, DATE: //-i9- /4/ Y, N NA COMMENTS: Chimney Height/ "B" Vent / Direct Vent Location V Plumb Vent Thru Roof Minimum t/+2u ,/ J + ARof Complete C �fJ Exterior Finish Complete /Finish Grade 6" In 10' Drop Interior/Exterior Railings 34 Into 38 in. / 36" Landing, / L'14.7:09r-A- Decks, Porches F� Exterior Handrails, Balconies, Landing 30" Or More , _ Interior Handrails Balconies / Landing 30" Or More ` jG�v`�� Interior Handrails Stairs 1 or More Risers t/ C-F 16101512- - Guardrails 42", Ballisters 4" Minimum Spacing ✓ � � Vestibules For Exit Doors > 3000 sq. ft. �Y� &'j4 Doors 36" / Lever Handles Vj �f Headroom 6' 8" on Stairs ✓ l4a 2L5 Bathroom / Kitchen Watertight I f raaeSmoke Detectors: Every level, Every bedroomOutside every bedroom, Interconnected Battery Backup Carbon Monoxide Alarm -lowest sleeping level / ��V44-4-4: Bathroom Fans / Plumbing Fixtures Complete V Vic-)-(5 Och''WCy�- Founepa na ion, 3/4,on V C 2 , Fire Separation, 3/a, 1, 2 hr. �`pY�-� Fire Walls 1, 2, 3 Hour/ Fire Door 3/4, 1 rh, 2 Hour Handicapped Accessibility/ Handicapped / - �� Parking/Signage V c _ _ _ r � �2� Gas Log In Sealed or Glass Enclosure �'�' - Gas Valve Shut-Off Exposed / Regulator 18" Above Grade `Z_ 19 Gas Furnace Shut-Off Within 30 ff. or Within Line Site F Oil Furnace Shut-Off at Entrance to Furnace Area o/ Furnace / Hot Water Heater Operating / Fresh Air Intake J / Low Water Shut-Off for Boiler ,70 V Relief Valve, Heat Trap / Water temp 110 Degrees Max. V Garage Fireproofing Complete, Penetration Sealed Furnace In Separate Room / Protected (In Garage) � . Light Ventilation per Room /Safety Glazing ���l Attic Access 30" x 20" x 30" (H) / Crawl Space 18" x 24" ✓ V Final Electrical Site Plan/Variance Required Final Survey Plot Plan / Flood Plain Certification, if Req. As-built Septic System Layout Required V k/ Building /Apartment Number on Building or Driveway Build Access Alt Sides by 20', Driveable Surface 20" Wide Okay To Issue Temp C/O or Permanent CO (circle one) Okay To Issue C/C L:\8&C APPLICATIONS-OFFICE USE\MULTIPLE DWELLING tloc Rough Plumbing / Insulation Inspec 'on Report ���/� Office No. (518) 761-8256 Date Ins'ectio rel '11 1i ,� ►� Oueensbury Building & Code Enforcement Arrive: = ' 742 Bay Road ue sbury, NY 12804 Inspector's Initial War NAME: A PERMIT#: -OS 7 LOCATION: l(Q ►�. �' �� l I SPECT I� 41 �} ,�ay TYPE OF STRUCTURE: �� 7A -11 Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head ou2f 50 ' .1. for for 15 minutes Insulatio1 Residential Check/Commercial Check 661L1 t t ‘C3EZ6Lt�� Window Sealing 1 zzt T or Similar Exterior Sealant roper Vent Attic Vent ✓ PwczNIEL Dior/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 0513 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury, NY 12804 Date received: _112cc- NAME: A a Q d Asto LOCATION: PERMIT#: Final Survey Plot Plan A t 'roved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the serve has been: // • �Nvice __ 4`17" 24 Se'e e + Notes: L:\SueHemingwayVBuilding.Codes.Inspection FORN(S1Final Survey Zoning Administrator,doe MAP REFERENCES: MAP OF A SURVEY MADE FOR JOSEPH R. ROULIER DATED NOVEMBER 23, 1987 BY VAN DUSEN & STEVES LAND SURVEYORS MAP OF A SUBDIVISION MADE FOR JOSEPH R. ROULIER DATED JANUARY 23, 2002 BY VAN DUSEN & STEVES LANDS N/F OF LAND SURVEYORS GARY BRUNELLE 1 I I I S82o_� 'f ' - - 08 00 E LANDS N/F OF ' SUSAN BAYER00 W — �' -- - 0 22500'- / LANDS N/F OF w - -- LAWRENCE LEMERY O m O O / S83°0 O Co 01501E - �. 2 STO�M� 48 O 0 249.22'Lo I W� 1JILOING / ry SB3°�1 iE 1056 w--- -- ---�- 5.0 / t �— - yE REVISED LOT 3 a -)/ice — � (., �Id s - - _ _ v/ 273,374.60 sq. ft. _ cUulN IT Ur WAKKtIN _ 160.00 N8301056°w I / 1 Ce LOT 1 \ / LANDS N/F OF, KENNETH SCHOLL �R 9S\ , / f 2� D-354 ro ri 43 N r) I 0 0 r] 0 z 1= o ti Q U � U ZO o a CL- Z p LLJ m o m 0 0 r z 0 A w+' o b o � x a Cd Cd w � Qom' oCd a o' w qo O E n €2ooe'sa H H04g'm' m= o —, F Normi opo os,�oga==0m aaryao �<a�`F'F`W naso =i5i a€wo _€ zv� m�roar Pa .r y .4, o o Lo CO " o c, C 0 0 z a A 0 0 v! CIO CoCr 0 p to o I D od x C Co Date, AUGUST 2, 2002 Scale 1•- 50' S-1 SHEET 1 OF 1 D'WG. NO. 01079-L3 D-354 ro ri 43 N r) I 0 0 r] Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Septic Inspection Report Inspection request receeii ,ed: 1D I d-OI4' I Ch 2r� Name: Inspected on: l a a- -r 1 4-LN,rS Location: d-1 A rive: 2tvra.m •.m. Permit No.: a'-0fq- '0S7 Inspector's Initials: Corn its and/or dia.ram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft Other wells: ft. Well Casing Length 50' +/- Y N N/A [150'to well required if NO} Absorption Field Total length ft Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits Number Size: x Stone Size: Piping Size Type Building to tank 3 r r 6CM HO R FC,OM M E OPED t tJCZEE\b t ►JCS Tank to Distribution Box Lt !► p �C...- n t ` Q 1 Distribution Box to Field I Pit 1' \ ?a \.ZE— ^V° `v � Opening Sealed: Y N End Cap Y N �JHGQET�EE at U\ K ES FRoM Inlet/Outlet Pipes&Baffles Y N Z v t\Jt T Q t t\ .0 Manholes 12"or less below grade Y N [provide extension collar if Yesj _Y N Location/Separations Foundation to tank /ft. Foundation to absorption Separation of Pits Conforms as per Plot P n Y �� EPTAC ,biEngineer Report an As-Built Y ETU Maintenance provided _Y_N f pt O --Bo\ L Location of System on Property: E Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Septic Inspection Report Septic Inspection Report Office No. (518) 761-8256 Date Inspection requ; -./ved: Queensbury Building &Code Enforcement Arrive: l , C, a r. A D:.'.rt: \o a /pm / 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: tie- NAME: GROLk i'AlJ0 '. IT NO.: 11-k —u6-7 LOCATION: Z t to CLN.R t F.FLIAPUPi AVE PECT ON: e1—`At>-1L} RECHECK: l Comments and/or diagram Soil Type: Sand mJv Type of Water: Municipal / Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - _Y_N_N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x — Stone Size: Piping Size Type Building to tank /2) PPrinif lank to Distribution Box i L.i" PVC' , 6LEES E- D 1 IJ Con 60/Qs PD Distribution Box to Field/ Pit ,I E Opening Sealed: _Y_N U w Q ER D Rt \ F`1bR`t R Q e IQ.. gaunt Inl utl Pipes&BaffleEnd s / N 0011 Ft o tJ bEP�I CT"e W}D 00_-` 1 Manholes 12 or less below grade Yes [provide extension collar if Yes] _Y . N Location/ Separations Foundation to tank ft. Foundation to absorption _ft. Separation of Pits ft. Conforms as per Plot Plan _Y N Engineer Report and As-Built _Y_ N ETU Maintenance Contract _Y N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear stem Use Statu . Approved Partial Approved and needs to be inspected, please call the Building &Codes Office Disapproved L:\Pam Wh01ng\2010\Building Codes Forms\Lorx‘Aion Forms\Septic Inspection Report_03 29 10.doc of Queensbury Building &Code Enforcement n _ /17 —laic, ice No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: a, A r own Inspected on: 9-or-( _ Location: (S� 6 PV 3 C. Arrive: to: a4,�_ ,i p,m, Permit No.: 1 �`C�5 5 Inspector's Initials: '�r •flRt1 AL_ Co, m• tsandlordia•ram Soil Type:Can4,Aoa Clay Type of Water 4 r' '!.P/Well Water Waterline separation distance ft. Well separation distance ft. Other wells. ft Well Casing Length 50'+/- Y N N/A [150'to well required if NO] 0 \K Absorption Field' Total length-7_,...e. 2 LD O ft. 0 \1—c0 G:kf WE 9-tie Length of each trench bp_ t ft. M l ov\ E PD Depth of trenches ` — ft �D�`� �F 4 Size of Stone - ERC \ \HEUtb . l.E4avE '. Seepage Pits: Number 3 L\oF.,5 ce cOy, OPEp To Size: x \re--K1F NJD C fl . R Stone Size: �Envok a O -eEt3O� o Piping Size Type T JER\ rF MiMaK CIJtJ' ctli)3 Building to tank e egr t tS5T'RLtE0 \--E3F L t,, L) OF- D"1i11Y, Tank to Distribution Box tt It 77 Distribution Box to Field I Pit tt P�� '-co ‘4" 9 f� pERF Opening Sealed. Y _ End Cap _Y_N 0E10 To feRaf-%( \--A57 3L\w-EI Inlet/Outlet Pipes&Baffles Y_N Air trati-r-kl3F9 CGF tYb tJ pT ‘0 FJ5Vr t Manholes 12"or less below grade Y N t [provide extension collar if Yes] Y_N t' Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft Conforms as per Plot Plan _Y V Engineer Report and As-Built Y V N PL E ASE PROQ l OE_ kb q1.51\....7 • ETU Maintenance Contract provided _Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use Statu . Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Septic Inspection Report Town of Queensbury Building &Code Enforcement Office No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: C Qr o vOd\ Inspected on: .49-i Location: C b 3 f Y-3 € Arrive: > m./� J Permit No.: 4-1-0S Inspector's Initials: ir \70Q-c-\q‘___ C'm •ntsand/or dia'ram Soil Type: Sand I Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells. ft. Well Casing Length 50'+/- Y_N N/A [150'to well required if NO] Absorption Field Total length ft Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size' Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed Y_N L/ End Cap N E►J� c $A� 1 C3bTBBLLEp ©``A TQ Inlet/Outlet Pipes&Baffles Y N 1 Manholes 12'or less below grade Y N 2)e c�F 1 LL ay3c)L (‘-t. - LE AO\ [provide extension collar if Yes] _Y_N LASJ b Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N ETU Maintenance Contract provided Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Septic Inspection Report Rough Plumbing / Insulation Inspection Report `�U es /- 3 Office No. (518) 761-8256 Date Inspection request r ed: Queensbury Building & Code Enforcement Arrive: y—DO a 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 3 .&rota s PERMIT It: LOCATION: (‘-‘) Kb A o INSPECT ON: TYPE OF STRUCTURE: A, � EOV) Y N N/A t� Plumbing under slab Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping CEA LA t36 Air/Head 50 P.S.I. for for 15 minutes c , �R�oQQ���Q =Insulation-/, Residential Check/Commercial Check \7b/ t.p_ ✓ —. V-Ack fah Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) LHEc Eist� Duct/Hot Water Piping Insulation If required unheated spaces �i 1 "J %- V©"•ThS Combustion Air Supply for Furnace . Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspectian_02 05 13 Town of Queensbury Building &Code Enforcement teNti Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: cit a ry 1. /1Inspected on: .a -- ' 1 Location: A �u\ Ey" p Arrive: AI r. __ a.m./p.m. IIt Permit No.: Y D �� Inspector's Initials: ak L.A TYPE OF STRUCTURE: Ps-p /5 V Y N N/A COMMENTS: Framing Attic Access 22"x 30°minimum Jack Studs/Headers Truss Specification Provided Bracing 1 Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12"C.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w)16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour c Firewall 2;3;4=hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re I . • J Queensbury Building & Code Enforcement Arrive: = r . % .." 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. r� NAME: Q COLO d1 PERMIT -. /</•–€25, LOCATION: d2bud {c/3. INSPECT I : g —i y TYPE OF STRUCTURE: U Tr/3i".h 1 Y N N/A Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1% inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes Insulation /Residential Check/Commercial Check WEST Z. SToR) Window Sealing W, Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent z' _- POL`1 p Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation , R-q \� If required unheated spaces Combustion Air Supply for Furnace VJRti.j Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 0513 We_.1 c2J-„ Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re . • . its Queensbury Building & Code Enforcement Arrive: e- 1Li� 742 Bay Road, Queensbury, NY 12804 Inspector's Initial-.t NAME: C Bft) L' n PERM! : Af-t57 LOCATION: CCZ►� fl Ue. INSPEC i , . 8=a)-11 TYPE OF STRUCTURE: Z 9T-c)t EA-5T ur3lT Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes s/ (-Insulation/Residential Check/Commercial Check \$c \� 12—k9 to4%ftb Window Sealing Q,__q o►sCi ixs4 Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed ( o Insulation) Duct/Hot Water Piping Insulation If required unheated spaces rv°ottM tagQ Combustion Air Supply for Furnace k-OttJVbr 9 Duct work sealed properly/No duct tape V00?--b Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 0513 Rough Plumbing / Insulation Inspection Report , % -ta Office No. (518) 761-8256 Date Ins •ction requ• Queensbury Building & Code Enforcement Arrive: e = P *7 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Cr' Ar pup PERMIT#: f /-y--e)5 LOCATION: Q'C 1kl)r INSPECT ON: TYPE OF STRUCTURE: Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head Eat— F0N7 50 P.S.I. for for 15 minutes vsJtar 'Insulation //Residential Check/Commercial Check ✓ k9 tZtt` t Window Sealing _ _} "'/ Tyvek or Similar Exterior Sealant VbtA 1)0 r ut � Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Foe- C E�Lv� , Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspeetian_02 0513 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ•. e/ved: Queensbury Building & Code Enforcement Arrive: 1 t;Cit. 1 i' 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: C-3Rn UJ 1J PERMIT#: 1q -057 LOCATION: Z. 1 CO (-11)E boo ANTE INSPECT ON cA-7aii—(1-1 TYPE OF STRUCTURE: Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes / Insulation /Residential Check/Commercial Check ✓/ s.}CC® a c_ctRETF Window Sealing VbC.4 Tyvek or Similar Exterior Sealant OpJ Z EHST oNTID Proper Vent, Attic Vent RVc\kcCV TiSFhcFti Door/Window Sealed (No Insulation) BE113 c-tj B_to Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insu lotion Inspection_02 0513 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: (3 Rou&3 Inspected on: i— A Alf Location: 2—t b Q UEE-eJ.MRoRR3E Arrive: " a.m./ Permit No.: —(1\57 Inspector's Initials: • — TYPE OF STRUCTURE: 10EhT 0 -v.1) z t�U' ? cX o L`/ Y / N NIA COMMENT : Framing V/ Attic Access 22°x 30"minimum / Jack Studs/Headers ✓/ Truss Specification Provided V Bracing/Bridging Joist hangers Jack Posts/Main Beams VVii Exterior sheeting nailed properly 12'O.C. V Headroom 366 ft.in,or . } ��-R 19, 100T , –� B���D Stairwells or more % . K7 Exterior Deck Bracing '/�/L l Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w)16 gauge(8) 16D nails each side • Draft stopping 1,000 sq.ft.floor trusses / Anchor Bolts 6 ft.or less on center V/ Ice and water shield 24 inches from wall Fire separation 1,2,3 hour ire wall 2,3,4 hour Firestopping V/ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off, if required Framing I Firestopping Inspection Report /3 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins'ection req. ,y��d Queensbury Building & Code Enforcement Arrive: VD 7 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. r NAME: C e CO w n PERMIT /k--b57 LOCATION: b 54,1 E. INSPEC 0 - TYPE OF STRUCTURE: ft- ekb z u3EJ5 0CMt S P A 9\71 Pk___ Y /N N/A Plumbing under slab V ("Reugh Plumbing /Nail Plates ✓� Plumbing Vent/Vents in Place 1% inch minimum Drain Size 10 Washing Machine Drain 2 inch minimum ✓ Cleanout every 100 feet/change of direction Pressure Test Drain /Vent /�/ Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test X er Supply Piping ead l9° 50 P.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 0513 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: RRfb3lJ Inspected on: i,—�.SSA? Location: Z\ l9 aoF_, 303 1 RAE- Arrive: A2T9# a.m�J Permit No.: ty '– Q5–] Inspector's Initials: TYPE OF STR . , •.' / F1Ur an 0101 Y N NIA COMMENTS: ilFramin� ✓ Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided / Bracing/Bridging ✓/� Joist hangers ✓/ Jack Posts/Main Beams N//1 Exterior sheeting nailed properly ✓ 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 11/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center v/ Ice and water shield 24 inches from wall i eparation 1,2,3 hour ire wall 2,3,4 hour 'res opp�g V/ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%:inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off, if required Framing /Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256Date Inspection r ques au: Queensbury Building & Code Enforcement Arrive: a l Jr 742 Bay Road, Queensbury, NY 12804 Inspectors Initials: Pk"- NAME: B ROiO0 PERMIT#: \Lk-0.77 LOCATION: Zl tQ QA.)E615;1)&1 NE JE INSPECT I ? — `B.—(L.11 TYPE OF STRUCTURE: 2- ERbV t)I1T,h y N N/A lumbing under slab Rough Plumbing /Nail Plates s Plumbing Vent/Vents in Place `, 11/2 inch minimum Drain Size �,,,(((// Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction ✓/ Pressure T stDrAir! j/j/ Air/ 5 P.� . . far 10 ft. above highest connection for 15 minutes Pressure Test fl• upply Piping \ ✓/ Head.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 0513 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: C3Rbu. t s Inspected on: Ca- I4 -.rca Location: al tO& v EEtb BU Q 4 E Arrive: 2:20 to a.m./ Permit No.: 14 -051 Inspector's Initials: A, TYPE OF STRUCTURE: R?Ft RTHE_Or Y ../ WA COMMENTS: T� Framing f Attic Access 22"x 30"minimum - --t c O M Pt F-rE. LATERRL (3 R RLQ Jack Studs/Headers / (3J AOOtt. �A1LE� GAB‘ -E ( truss Specification Provided V/ racing/Bridging ✓ E DO3 Joist hangers ---, lt3_bTHU__ FLOOEL Ux0GN1x7 Jack Posts/Main Beams V Exterior sheeting nailed properly l&3 T-Bl_L f\i 3CNoR eaT.b wkNE 12"O.C. Ckb Headroom6ft.8in. Silbblt3� 00 C:3171461 Stairwells 36 in.or more O F 2'OT7(3-\ 2k-VE .6 F\CE5 e a Exterior Deck Bracing Le FQot\ bc t. Coes 1�'S Headroom 6 ft.8 in. " >7-RA1.lb 1T% 3c3 P1 ECE u3 t LL B Notches/Holes/Bearing Walls ,f EEO Ep cJ FPor-st pcc z3—irk Metal Strapping for Notches Top Plate CTQ1 Pi: t.3 l;AzaRD) 1 '/ (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses V 11�7E1 .._ PCe U !-IRT �JPRE6� U` -E_ *Anchor Bolts 6 ft.or less on center f EQ \*lt-k s -(Z POtat`T Ice and water shield 24 inches from wall 'L_oOg dE -tA (3 Qt EQ. t�F\cQE Fire separation 1,2,3 hour / . Fire wall 2,3,4 hour d / Firestopping r.1 FFD TO F t RFhmP 41-kectuan L Penetration sealed 2107-1; 61 Di�tu FLDOR41 CEll-1136 OF 16 inch insulation in cavity min. z_00 Garage Fire Separation FLooR u.1 P'OC�`wtJOl House side 1/2 inch or 5/8 inch Type X �/ Garage side 5/8 inch Type X * t' C t'��- TE 61� K F1 V_ j &! Ceiling/wall / �T '7f7�5 01;7 F_�� 01.W1-6Windows Habitable Space/Bedrooms Y/ \1 Q D t �G \I-tJ NTS,5 24 in.(H) t// 20 in.(W) Vit 5.7 sf above/below grade J/ 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ Queensbury Building & Code Enforcement Arrive: Z Z© ;Cr 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Ai- NAME: Q Rom PER''( LOCATION: 11 (s) Qv E JUa? EINSPECT ON: 14-1 TYPE OF STRUCTURE: _ ► 49" T to IA Y , N N/A 'Iutibing under slab QCM_VtttTES ' ' r ' J 11/2 inch minimum Drain Size Washing Machine Drain Cleanout II feet/change of direction Pressure Test Drain ITS h RIJcrAR`Air/Head � i ft. above highest connection for 15 minutes Pressure Test 014 Water Supply Piping 'Teal" R Air/Head I for for uiation /Residential Check/Commercial Check indow Sealing TWEICVirlingEitEinnintir Proper Vent, Attic VentJ IiiWindow Sealed (No Insulation) Duct If required unheated spaces d I ontistion Air Supply for Furnace 4 r sealed .pe Iyr/iNiduct¢ape PRR-hi{L A ? COmill_ L Blower Door Test e atn ce_ o f Air Sealing Eoo \SoocT COMMENTS: © cotia_Et E FRRMMrJC, A ,tiRG tV 3G FoR ExTG�to� u3 Fi LL5 RuFt � . RooEB \la F�FcT-�tC. uJ t LC TttE F ��1c RtL5 `T e\zhb ‘ 't• o Rocz Tb 6c \ g 0 u\ t V HouPlumbing_Insul tion Inspection_02 0513 Town of Queensbury Building &Code Enforcement "/&t�S / Office No. (518)761-8256 Framing I Firestopping Inspection Report Inspection request received: � \\ Name: Cj f G��lJ Inspected on: --_,� Location: V E Arrive: a Am. p.m. Permit No.: 57Inspector's Initials: -a TYPE OF STRUCTURE: N WA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w)16 gauge(8) 16D nails each side Draftcstopping 1,000.ores.ft.floor trussese Anchor Bolts 6 ft. less on center [veld 24 inches from wall ��77� Fire separation 1,2,3 hour D EQ_` ,513 Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing I Firestopping Inspection Report Town of Queensbury Building & Code Enforcement ter td Qt,� / —3 Office No. (518) 761-8256 C� Framing I Firestopping Inspection Report Inspection request received: pp Name: c A V Q tA° A Inspected on: —/g Location: Qty -No E Arrive: o Ar/ p.m. Permit No.: -b 5 7 Inspector's Initials: ' ' TYPE OF STRUCTURE: n•y t77.1_ cv,.- -ctsriopy7---/ ‘NA.62..a.;....ne,co_ou 1>7 NIA COMMENTS: Attic Access 22"x 30"minimum - Jack Studs/Headers ✓ ( v 0�a Truss Specification Provided / r V'\CL A-CCE66-4\SC nrr"--- Bracin /Bri n ✓ v t�1j \� LIT`, RCS ,yam - Joist hangPosts/sMin Bea 1/2b r L OP, ✓ v E Jack Posts Main Beams ✓ �� Tv O{�QR G� Exterior sheeting nailed properly D ctg 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls 136 t A LLT Metal Strapping for Notches Top Plate F c. \ 1'c�tJ�?SCup�j toNk W 1 %:(w) 16 gauge(8) 16D nails each side ��T� �\ fl t-W±M\ ft stopping 1,000 sq.ft.floor trusses d�T� �$� \ C 'V , 'char Bolts 6 ft.or less on center ' / `�Eb ( -and_watershield-24 fns es from wall— -—7 / LO��R VEW F bt\l Fire separation 1,2,3 hour - — Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report - 1,6a"� Office No. (518) 761-8256 Date Ins'ection reque t: 6/9/01.0/1 Queensbury Building & Code Enforcement Arrive: e : fi ,'' 742 Bay Road, Queensbury, NY 12804 Inspector's Initia . NAME: LJ /h �S� PERMIT e 04_05 7 LOCATION: 02/ Ca �l� A& INSPECT ON: 'fry 9 an)/ Gr fy., AUTYPE OF STRUCTURE: �r v fr7---AtirtaT_ Y7 i° Aar / Y N N/A /, , A. tkerC- -dumbing undunder slate v`" Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction / P - Test D n /� Dr. n rent JJ/ Air ead P.S.I. f t r 10 ft . t ove highest connection for 15 minutes /, Pressure T•st F✓//� pl iping V I ' : . for for 15 minutes . ation / Residential Check/Commercial Check 0.5.) -A Window Sealing gr.Tyvek or Similar Exterior Sealant gi��C.Ey Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumhing_Insulation Inspectian_02 0513 CI cn Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: m 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:��A C `' ✓I NAME: C.k o4,% b fI� our% PERMIT#: h --d S� LOCATION: at � b b Ts V e INSPECT ON: L' I a-"s `I TYPE OF STRUCTURE: 4 Comments N N/A Footings Piers Q C.31/4 Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Stone: 12 inchch width 6 inches above footing &6 mil polyforw`et=areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper � \ Foundation Insulation Interior/Exterior V/ /) R- /0 Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM riztdt�Gst -3 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection e uest re v-. Queensbury Building& Code Enforcement Arrive:2)1-/ a Vie' . Depart: -a .. pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial. NAME: G g J'i7u° n RMIT#: i q-b 5 / LOCATION: &I (p Ob t1 A" 0 C. INSPECT ON: --36—J Y TYPE OF STRUCTURE: ,p FFjt Comments \ � Z -- Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches ybove footing 6 mil poly for wet areas under slab ' akco ` f :pprovai Plumbing Under' Slalabb PVC/Cast/Copper a Foundation Insulati.v• nteris -nor R-gyp t Fr", ' ice_ Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM -OD Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request Queensbury Building &Code Enforcement Arrive: 3•-cO. • r 0111110 epart: 7 1 . pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial NAME: C rats( G} a rb L¢7 f� PERMIT#: / ---(5 S LOCATION: 2.-VD b e INSPECT ON: —21 -1H TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing (� for 48 hours following the placement of the concrete. Materials for this purpose on site. / O� Foundation/Wallpour Y /, \ Reinforcement in Place �� Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval • Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM fed, 1- 3 ( pm) Foundation Inspection Report Office No. (518) 761-8256 Date Ins ection requ . d: Queensbury Building&Code Enforcement Arrive: 1 -X)• f.% Depart: \'_L1 anp.6......" 742 Bay Rd., Queensbury,0.NY 12804 Inspector's Initials: NAME: C UrDwo (Mrr#: /1-0 S / LOCATION: AiI & 69 fl'V a INSPECT ON: 5 -.Is /y TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this puon site. oundation:/ allpour Reinforcement in Place `/ Footing Dowels or Keyway in place t��17� ch � Foundation Dampproofing `\ Foundation Waterproofing \)1 \--7- Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM Foundation Inspection Report CAS Office No. (518) 761-8256 Date Inspection re. : •e. ed: s Queensbury Building&Code Enforcement Arrive: "VD Depart: 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi.1 r NAME: B r0 U) n .ERMIT#: 11<, '65 7 LOCATION: (Rita. ( 1p Lt P'O e i 1 SPECT ON: 5 m -141 TYPE OF STRUCTURE: !4-C kb Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM