Loading...
2013-020 TOWN OF QUEENSBURY i 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20130020 Date Issued: Thursday, February 27, 2014 This is to certify that work requested to be done as shown by Permit Number P20130020 has been completed. Location: 31 KNOX Rd Tax Map Number: 523400-239-007-0001-007-000-0000 Owner: GREGG & LIZABETH BROWN Applicant: GREGG & LIZABETH BROWN This structure may be occupied as a: Boathouse By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property / owner of the responsibility for compliance with Site Plan, Variance, or el r other issues and conditions as a result of approvals by the Planning Board 4 Director of Building&Codc Enforcement or Zoning Board of Appeals. 0104 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130020 Application Number: A20130020 Tax Map No: 523400-239-007-0001-007-000-0000 Permission is hereby granted to: GREGG & LIZABETH BROWN For property located at: 31 KNOX Rd in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GREGG&LIZABETH BROWN 34 DEER RUN Holw Boathouse CLIFTON PARK,NY 12065 Total Value Contractor or Builder's Name/Address Electrical Inspection Agency DEAN HOWLAND 7 IROOUOIS STREET LAKE GEORGE.NY 12804-0000 Plans&Specifications 2013-020 Boathouse Renovations to first floor;re-do siding $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,January 23,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town f Que sbu/ W..i e•)%a anuary 23,2013 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement e OFFICE USE ONLY fp , ,TAX MAP NO. PERMIT N0. 0..�aAl y e •FEE PAID %J/ &CODES APPROVAL ` - �/ ; •; tC ; 1 • ! `;:J2013 ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. • • - A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: 'k v ILUeisv 46/4a0,4 INSTALLER/BUILDER: 4Qd � f 63,cL577 70.) ADDRESS: 3/v 7600 X I , t1g1.e.25L nl, ADDRESS: / 5 { 6,4 g 4p/25 PHONE NOS. d.5G-- 9980 PHONE NOS. 5/8 G 3/65- ('BLL '67 LOCATION OF PROPERTY: 31 Koox Ref, 00,ezn2d04.9 SUBDIVISION NAME:p / LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: 3/ ,xx.&f Aj, ,5l7ua, HAS THERE BEEN A SITE PLAN REVIEW:VARIANCE OR SUBDIVISION APPROVAL? 0 YES OK-NO , IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: ESTIMATED COST OF CONSTRUCTION: $ 7J'%YI ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: PROPOSED CONSTRUCTION in FLOOR 2HD FLOOR TOTAL PROPOSED SQ.FT. SQ.FT. SQ.FT. HEIGHT FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH' BOATHOUSE /10 ---O /757) BOATHOUSE WITH SUNDECK e3ba,tht/t40.___ . . DOCK pi,-,a-vr,6‘,-17-5-- SHED is cif . o POLE BARN 0 rc_1) , r DETACHED GARAGE(NO.OF CARS: ) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO].REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL T61.8256 OR EMAIL I have read a e to t�'e abov� codesCcDaueensburv.ne> / VISIT OUR WEBSITE FOR MORE INFORMATION Signe ,„,,,--„p 4, , ,..,-p ." Dated: /1-01-6 www.aueensburv.net la • Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart:2` am/pm Date Inspection request received: Inspector's Initials: NAME: rD u J1 PERMIT#: / 3 /2,. .z). LOCATION: \3 / ny Rol DATE: 2[005 Ii(.-. TYPE OF STRUCTURE: ( tx h 01 t SC� Comments: Yes No N/A 4" Building Number Address visible from road e alt ( -4 L,)(ak✓4 Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake r79/— 157 ILe 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete CC C, l ►/ Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Y Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codeslinspection Forrns\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 ,��.; . /-3 . - Queensbury Building & Code Enforcement - Residential Final inspection Office No. (518)761-8256 f Arrive: am/p Depart: . am pm Date Inspection request received: I I(o 14— Inspector's Initials: NAME: ,IS1 � I- PERMIT#: �t O/3 "d 6 LOCATION: ► n �`- DATE: /1/7/moi 1/G TYPE OF STRUCTURE: Lid-)1%62,-6-e___ r- Comments: �- Yes No N/A /, 4" Building Number Address visible from road I CT "�D Q Chimney Height/"Ba Vent/Direct Vent Location Freshake (-71,4,:t 1 �L� i 3 inch Plumbing Vent through roof minimum 18 inchesdi1 ? x-^C Roof Complete/Exterior Finish Complete �-J Platform at all exterior doors 7v / / Handrail 4 or more risers 79/— Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more G Guard at deck, porches 36 inches or more ,�/ Li``ej -- Handrail Termination at Newell Post or Wall � � Interior/Exterior Railings 34 inches to 38 inches (`74_`ALL Deck Bracing/Handicapped Ramp Compliant G,i'1) i.--e 12 Grade away from foundation 6 inches with 10 feet r i`eta•-/—I 6 inch clearance to sill plate atJ�l`.... • Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches I n , Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing �_. Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Ev Bedroom: Outside everybedroom rea. �� Inter Connected: Battery backup: I 1� i r--7,\N\J rs Attic access 30 inches x 22 inches x 30 inches(height)in accessible area _ / Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents \..- l 7-0``QL- Bathroom Fans,if no window _ __ Plumbing fixtures Foundation insulation to floor/Sticker on Panel t,�---.._ Duct work sealed properly/Blower Door Test Certification �� Floor truss,draft stopping finished basement 1,000 sq.ft. 7.�"Z —(. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing 1%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure y! Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent] 9..) L:\Building&Codes Forms\Building&Codesllnspection Forms1Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 t( / �� Rough Plumbing I Insulation Inspection Report ; Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: if am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: la's, V" ) NAME: it . A. PERMIT #: /3- 0-A0 LOCATION: 3 I f 'r j 4 _ INSPECT ON: TYPE OF STRUCTURE: Y /N N/AI Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 ' inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent ‘J/ Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape COMMENTS: ? tk=-4- tc)q----e) 12, — Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Framing / Firestopping Inspection Report LANACI Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart. am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Ejtj,L7 r i n PERMIT#: / j - CU LOCATION: , � L_ nr X_ !��c INSPECT ON: -q /j-13 TYPE OF STRUCTURE: 1 Y� N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing /Bridging -- ✓'rl. �--��•T U�� Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches / Holes /Bearing Walls Metal Strapping for Notches Top Plate 1 'A (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall _ Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/ below grade 5.0 sf grade L:\Building&Codes Forms-OLD\Building&CodesUnspection Forms\Framing Firestopping Inspection Report.doc Revised January 7,2008