Loading...
2013-185 TOWN OF QUEENSBURY Bay Queensbury,742 Road, ueensbu NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20130185 Date Issued: Thursday, July 18, 2013 This is to certify that work requested to be done as shown by Permit Number P20130185 has been completed. Tax Map Number: 523400-297-010-0001-052-000-0000 Location: 667 RIDGE Rd Owner: ALEX ALEXANDER Applicant: ALEX ALEXANDER This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the / property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Cod` nforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY T 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 a Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20130185 Application Number: A20130185 Tax Map No: 523400-297-010-0001-052-000-0000 Permission is hereby granted to: ALEX ALEXANDER For property located at: 667 RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ALEX ALEXANDER Septic Alteration Residential P.O. BOX 4024 Total Value QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency STONE INSTALLATIONS 232-6707 4305 STATE ROUTE 50 SARATOGA NY 12866-0000 Plans&Specifications 2013-185 Res. Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, May 13,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o eensbury Mo t ay May 13,2013 SIGNED BY for the Town of Queensbury. Director of Building&C e En cement A-177 - Community Development Office MA!' 2013 _,i Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 Office Use Only r TAX MAP NO. I /, I D " ( - J/ PERMIT NO. 13-- I 'g5 PERMIT FEEti. .( - �1� APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: BRITTANY & MEGAN ALEXANDER INSTALLER: STONE INDUSTRIES ADDRESS: P.O. BOX 4024, QUEENSBURY NY 12804 ADDRESS: 4305 ROUTE 50, SARATOGA SPRINGS NY 12866 PHONE NOS. (518) 792-4917 PHONE NOS. (518) 232-6707 LOCATION OF INSTALLATION: 667 RIDGE ROAD RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION = TOTAL DAILY FLOW BEDROOMS (Gallons per bedroom) GARBAGE GRINDER 1980 or older X 150 = INSTALLED? N/A 1981 -1991 X 130 = SPA OR HOT TUB 1992-present 7 (B&B) X 110 = 845 INSTALLED? N/A + 75 GPD (BAKERY) PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING / STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM ✓ CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? 27" PSHWT ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? >80" ✓ DOMESTIC WATER SUPLY: MUNICIPAL ✓ WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS 1:00-5:00 pER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: (2)1,000 GALLON(MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. (1 EXISTING; 1 NEW) SYSTEM TYPE: EXPANSION OF EXISTING ABSORPTION FIELD FROM 150 TOTAL LENTH TO 350 LF ❑ ABSORPTION FIELD (WITH NO.2 STONE) Total length 350 ft. Each trench 7 X 50 ❑ SEEPAGE PIT(S)(WITH NO. 3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? 0 HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circu . e known by or on behalf of an applicant,shall be void. I ha -.• t�gulations wi j resp-ct t4this application and agree to abide requira -nts : •wn of Qu nsbury QUESTIONS? CALL 761-8256 OR EMAIL Sanit��1�Q.. Disposal Or.111 anc' ' codes@queensbury.net mil •' A. •H + VISIT OUR WEBSITE FOR MORE INFORMATION Ans.atur- •f Person Respon ible A Da www,queensburYnet Septic Inspection Repo Office No. (518) 761-8256 Date Inspection reqi. •iv=•: Queensbury Building &Code Enforcement Arrive: -�•Prj►e••rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial � ,r- NAME: P:' NO.: \77-19‘'.5 LOCATION: (0 (n7 (r-\ 1 AE I) •ECT ON: 7-1 7-12) RECHECK: Comments and/or diagram Soil Type: Sand / Loam / Clay Type of Water: Municipal/ Well Water Waterline separation distance __ ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: _Y— N End Cap _Y_ N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade _Y_ N [provide extension collar if Yes] Y_N Location/ Separations AS BUILT Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y_ N Engineer Report and As-Built Y.., N ETU Maintenance Contract Y N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use Sta s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering Phone: (518)745-0307 Fax: (518)745-0308 July 9, 2013 Town of Queensbury Building Department 742 Bay Road Queensbury, NY 12804 Re: Septic System Installation Brittany & Megan Alexander, 667 Ridge Road Tax Map # 297.10-1-52 Our office prepared a wastewater replacement design for Brittany & Megan Alexander at the above-referenced property. The system consists of two 1,000-gallon precast concrete in series septic tanks; a leach field with 22-inch open-bottom gravelless chambers and 7 trenches at 50 feet each for 350 LF of trench; and an existing 1,000-gallon precast concrete pump station. A representative from our office visited the site during system installation. Based upon our site inspection and our discussions with the installer, it is my opinion that, with the exception of surface finishing and turf establishment, the system was installed in general conformance with the attached record drawing. Please contact me if you have any questions or if you require additional information. Best Regards, •itimm. G. Nomas ,tchins, P.E. Enclosure (1) G.Thomas Hutchins,P.E. Septic Inspection Re y. - Office No. (518) 761-8256 Date Ins•- •on -• ' ed Queensbury Building &Code Enforcement Arrive: ` 6 a • ' ••rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi — NAME: ALF LCD E P'RMIT NO.: 13-\Q- 5 LOCATION: (p R\0 6E Rv NSPECT ON: c' -17) RECHECK: Comments and/or diagram Soil Type oa _ Clay Type of Water u 1" "•. ., • _Water Waterline separation distance \Q ft. {- Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] 3 Absorption Field: Total length 7i��U ft. Eo Length of each trench k5-0 ft. Depth of trenches \ -\`{ y Size of Stone -L Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank y " ./,G\- -k Q- Tank to EstributlifirrIlkortJ E•3 \nc�c> T'A c31 - 1-0 tock-_\ L\ Di r Opening Sealed: ix) N oo ,i z T To C13t1PbTi�"C"‘oc� L\`\ 5Q\\ yp End Cap N "1"-b M(�'JTRT�iJcJ �b �tJ O- ‘7i- \ply"P�� r oczMa Inlet/Outlet Pipes &Baffles N " p‘)C d Manholes 12"or less below grade ✓ N [provide extension collar if Yes] / N v - F E\--D Location/ Separations Foundation to tank 'ND ft. Al— Foundation to absorption o c ft. -'i- Separation of Pits ft. Conforms as per Plot Plan Y �1 Engineer Report and As-Built Y EECDPoc2_7" akl‘�-� ETU Maintenance Contract Y_ N provided Location of System on Property: Front Rear / L-" Sider t'_ ide Middle Front Middle Rear System Use Statu . Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Bullding Codes Forms\Inspection Forms\Septic Inspection Report03 29 10.doc LEGEND: Q IPF = IRON FIFE FOUND Q IRF =IRON ROD FOUND ® = WELL WOOD FENCE — o — = METAL FENCE = STONE WALL I = EDGE OF WOODS MAP REFERENCE: I TOPOGRAPHIC BASE INFORMATION FROM "MAP OF A SURVEY MADE FOR BRITTANY & MEGAN ALEXANDER' BY VAN DUSEN & STEVES LAND SURVEYORS RF II OF QUEENSBURYNY AND DATED DECEMBER 20, 2012. EXISTING WASTEWATER SYSTEM INFORMATION FROM "REPLACEMENT WASTEWATER DISPOSAL SYSTEM, ALEXANDER WASTEWATER" BY JARRETT MARTIN ENGINEERS, PLLC OF GLENS FALLS, NY DATED AUGUST 2004 AND REVISED 11/24/04. S86----0 E 268.55 ........ -\..•.....r...�:.. ...-.--..:. \� \\ - ._'... \ ... ,i _ _._ - —' 3._0_ "E o 7 /7, 30'REAR BUILDINGSETBACK 1iV PROPOSED SILTFENCE WOODED PROP / PROP. BUFFERLOSED IIMITCLEARNG PLANTINGS O PROP. - PAVEMENT " !Pt�' 3 ; ats, ' ..... . x .......... . SITE LOCATION ......... ........... .............. ........::.. LO o o ,..:::. ":. .. :..:::::...... - �� r✓ NTS LOCATION MAP \.... . ,..:.., ai:: .. g:':::::?::::?:C :'::.:.".::'::'i:'i:::' I WOODED P O ... 12 OeG .......... .: - / - ti V. .. -.. n __. .:: l9 DEC �. A, SITE DEVELOPMENT DATA TOTAL LOT AREA 3.19± ACRES 138, 956± SF strator or Bwldm on d Codes ersonnel ew b the Zomn Admmi P ren 5 Y 9 I i � iaff TOTAL DISTURBANCE 14,000± SF (REDUCTION) o i I EXISTING IMPERVIOUS AREAS PROPOSED IMPERVIOUS AREAS CHANGE IN IMPERVIOUS AREAS HOUSE 2,362 SF 2,472 SF 110 SF DETACHED GARAGE 412 SF 412 SF 0 PORCHES & DECKS 112 SF 239 SF 127 SF ACCESSORY STRUCTURES 124 SF 124 SF 0 PAVED SURFACES 4,557 SF 8,907 SF 4,350 SF POOL 378 SF 378 SF 0 uilplans to certify that the site pla is developed according to 14) As-built Brittany Megan Alexander TOTAL IMPERVIOUS 7,945 SF 12,532 SF 4,587 SF -.TOTAL PERVIOUS `° " 131,011 SF ^ 126,424 SF (4,587 SF) PERCENT PERVIOUS 94.37 '. 91.07 (3.37) o u 4 ....... �.:. t .... 0 ZONING REGULATIONS -_ ••: - . �.:. � >` TOWN OF QUEENSBURY rO "h/ MDR MODERATE DENSITY RESIDENTIAL O gL DIMENSIONAL REQUIREMENTS: r APPROVAL RES FRONT SETBACK 30' ;; RESOLUTION 2/26/13 - :. DO bur Plannin i' Board q T Y g REAR SETBACK 30' ,.... �, RESOLUTION TO APPROVE SITE PLAN, SIDE .SETBACK = 25' ( , _ - ANY ALEXANDER &MEGAN PROP. GATE .. ..>•:: ALEXANDER A site Ian application has been molds 2073 BRITT MINIMUM PERCENT PERVIOUS = 50% ........... ..::.�.,....... ... P P r de to the Queensbury Planning Board for MAXIMUM BUILDING HEIGHT 40' -- - the following: Applicant proposes conversion of.a, three 3 bedroom single ,:... - a * r •$.- PROP. SIGN -;`:: _: family residence ianMDR ions res uires)Pbedroom Bed and Breakfast. Bed and 4I � Z ... Breakfast q tanning Board ieview and approval. - o o r , PARKING REGULATIONS I w •£ ,. � ` ,�.A public hearing was advertised and held an 2 26 O \ _- .i�. "Sp r, PROP. YHIGH ''r'G :::: ::�s: �'. ed with: ll documental2013; PICKET ENCS ,�. -,+:. PIC ET FENCE "This o lication 1s supported i PICKET FENCE �. O , ., j.,._ - -. _ Gabon material mP he file of re ord,-on, Public comment, and apply I TOWN OF QUEENS BURY 1,000 BED & BREAKFAST BUR 1 Y O GAL. SEPTIC ti �_-..- ON TO APPROVE SITE PLAN NO�7-2013 BRITTANY ALEXANDER & MEGAN PROP. EFFLUENT PARKING REQUIREMENTS: APPROXIMATE EXISTING TANK TO REMAIN 4w • „ - ALEXANDER. Introduced by Brad ago wan who p m ,'r '' PT -I r'.SEV✓ER - _ r —' — — - -` - r: seconded by Stephen 'moved for Its adoption, i SPACE/GUEST BEDROOM + 2 ADDITIONAL SPACES I r WASTEWATER SYSTEM, (3) % _ — �J T r , 5 GUEST BEDROOMS '= 5 SPACES .+ 2 ADDITIONAL GRAVELLESS CHAMBERS AT 501 EACH 4 TP -1 EXISTING PUMP �;: f,4 1:Acrording to the resolution prepare by Staff with. the following findings and - S REQUIRED = 7 - m ! .: STATION TO REMAIN - : . SPACE Q conditions: - 1I SPACES PROVIDED = 7 on / — wn of Queensbury' Zoning (5 IN PARKING AREA & 2 IN GARAGE) n _, _. S - .r,,.,} ,. :__r.._ . ' PROP: GATE i�. Code Chapter 179. 9-080, the, Planning Board, has determined that this I n - � � S 1) Pursuant to relevant sections, of the 70 PROP. WASTEWATER SYSTEM i TP -2 EXPANSION' 4 ADDITIONAL 22"hy / .. 2,g`O ' / proposal satisfies the -requirements) as stated the Zoning Code; O RY 2)The requirements cf 2he State 1. Environmentali Quality Review Act have ELLESS CHAMBERS AT 50 LONG p GRAV .m* .....; '' oI' Board has adopted a SEQRA Negative «... -.... / been considered and the Planet op 9 9 0 R . EACH (SEE ABSORPTION TRENCH PROP. FORCEMAINDeclaration; QB6 - � '�: - SECTION & PROFILE FOR DETAILS) , 3 � � i p „ s .. w. ..4 e a3 �, 3)Waiver.-requests o�ran ted:i 1, Topogra - g mg; Stormwater' EXISTING BUILDING ,,;., f r h r . r PROP. D -BOX,' REMOVE a' 3 _- �9 / i ' and Lighting; - 'r EXISTING D -BOX AND RE -PIPE ' 'SEWER TO REMAIN PO/j- ` .'i5 .. p _,_ .S /- / �''. p! -' -- z- ; `-' / 4)The limits of clearing will constitute Y Landsc� cut buffer zone, orange - ■■ :( nnstufe a roan AS �� - PROPOSED SILT FENCE ii r. EXISTING ABSORPTION f r / : - 9 ' staff se areas and field _ i i --- �FilBdOICLiES TO NEW D -BOX `',. Aa4ND _ r % r verified b Community Developmentd the �. O -. ONED Y P ' ' .. - - r construction fencinshall be installed arom - ' WELL / ,5)The SanitarySewer connect! n Ian must be submitted to the Wastewater Department for ds tri view, appro 'permitting and inspection; ,i v-{ 492'6lf curb cuts are being added o changed a' driveway permit is required. ). 9-1-52 _. 1 %r � 7. ��' leen g P t 't be Pan issued until tte., approved driveway permit TAXMAP 1f 297.10 PROP. 1,000 GAL. PRECAST , , El�/ has bprovided totheni't g Office; kF4 391 �I /,, 1 _ CONCRETE SEPTIC TANKTO „ t. - Sp r CK - / " 7 Additionally, we'd like to replace. the black a•' that )rou propose with an ALTERATION OF GINEERSI A VIOLATIONMENT GEPT BY A OF NYS EDUCATION LAW. �r � � g ILDING SETBACK � / , ) Y �I PROFESSIONAL ENGIN WOODED 3 ✓ oak or maples; J t 39 !1E INSTALLED IN SERIES I 3 / Sr / - e)And that the four .lights on the, g g 0 FRO WITH EXISTING SEPTIC TANK % ! } - arae wit be motion activated and downcast; L. i �. vl � I I A f busineef i ate Department - - % of Health for the cake and cupcok i 10) Also, signage slat I they end of the ndrivewa efor Ya recommendation to 2 RECORD DRAWING 5/22/13 turn right due tothe concerns if thenature�of the comer, - - - i _ ✓ "" - - - I� 11) Final approved plans, in compliance withi submitted the Community Development D the Site Plan, must be 1 REVISED SITE 3129113 113 ailment before an further �, 0 ISSUED FOR SIT Dig Safely. NewPdYork E] Call Before You Dig ® Walt The Required Time ® Confirm Utility Response F] Respect The Marks ® Dig With Care 800.962.7962 www.digsafelynewyork.com - s - .-- -- i _ �' strator or Bwldm on d Codes ersonnel ew b the Zomn Admmi P ren 5 Y 9 I i � iaff D o i I — r f2 Theo licont m after a roval on d rior to issuance -P IVO. S82of Building Permit and/or the bgmmng of a work OO uan eecef with a i�, d �dudmg building permits is 13) Subsequent is P lu i dependent on comphan I other conditions of this F N �'�"� �L�' resolution; �. i Prepared for. _-" uilplans to certify that the site pla is developed according to 14) As-built Brittany Megan Alexander the approved Ions to be rovided to asuance of the certificate of PP P P pylar occupancy. !f .& - da of February, 2013, b � the following vote: Duly adopted this 26th 9 Y 667 Ridge Road f ' Town of Queensbury, Warren County, NY AYES: Mr. Traver,' Mr. Magowan Mr. Peron ei, Mr. Deeb, Mr. Sipp, Mr. PLAN N. er Dr9Wn: DAG Checked: GTH Scale: NOTED Date: 01/02/2013 169 Haviland Road SITE NOES. :.NONE SCALE: 1"=20' ABSENT., Mr. Schonewolf Queensbury NY 12804 T29669-01-52 l Cc Hutchins Engine ering I 518 745-0307 Phone i Engineering Hutchins En 745-0308 Fax 9 9 (518) - F_ � _ -. , --_. ,a. .� .- w :, „m F _ ... .n -.ray _.�srui.,... -- • k";&§t.' tl �ai� EXISTING ABSORPTION LATERAL TO REMAIN; (3) AT 50' LONG EACH FILL MATERIAL 4" MIN. 6' TYP. TRENCH 6' MIN. TO TOP TOPSOIL SPACING OF TAPER , c rr ncuvnr i E vry mcrv�n; (4) ADDITIONAL AT 50' LONG EACH REQUIRED (SEE ABSORPTION TRENCH SECTION AND PROFILE FOR DETAILS) ABSORPTION FIELD SECTION NTS 4" MIN. TOPSOIL OVER - ENTIRE ABSORPTION FIELD; SEED & ESTABLISH TURF nncn n"u �c unit rn .WIDTH PER PLAN CONSTRUCT BERM 1 4" PER FOOT 2-3" MULCH AS NEEDED MIN. SLOPE W TER FLOWS NATIVE PLANTINGS, ---- . Y SEE SCHEDULE -n -uv�, 4" SEWER FROM — V0111: , ORGANIC TOPSOIL BUFFER PLANTINGS DETAIL NTS ACCEPTABLE PLANT SPECIES BOTANICAL NAME i COMMON NAME HERBACEOUS PLANTS (PERENNIALS, GROUND COVER) MONDARDA DIDYMA BEEBALM IRIS VENSICOLOR BLUE FLAG IRIS VERBENA HASTATA BLUE VERVAIN TYPHA LATIFOLIA BROAD LEAVED CATTAIL LOBELIA SIPHILITICA GREAT BLUE LOBELIA EUPATORIUM JOE PYE WEED THALICTRUM DIOICUM MEADOW RUE MEADOW VERNONIA NOVABORICENSIS NEW SENNA HEBECARPA WILD SENNA SMALLER TREES & LARGE SHRUBS (UNDERSTORY) VIBURNUM TRILOBUM AMERICAN CRANBERRY ARONIA MELANOCARPA BLACK CHOKECHERRY CEPHALANTHUS OCCIDENTALIS BUTTONBUSH SALIX BEBBIANA BEBB'S WILLOW SPIRAEA ALBA MEADOWSWEET NEMOPANTHUS MUCRONATUS MOUNTAIN HOLLY LINDERA BENZOIN NORTHERN SPICEBUSH ARONIA ARBUTIFOLIA RED CHOKECHERRY CORNUS SERICEA RED TWIG DOGWOOD SALIX LUCIDA SHINING WILLOW ALNUS INCANA SPECKLED ALDER SPIREA TOMENTOSA STEEPLEBUSH MYRICA GALE SWEET GALE LLEX VERTICILLATA WINTERBERRY HOLLY HAMAMELIS VIRGINIANA WITCH HAZEL PLANTINGS NOTE: PLANTS SHOWN ARE MINIMUM SUGGESTIONS; OTHER PLANTINGS ON THE SITE ARE TO BE CHOSEN BY THE OWNER EXISTING SEPTIC T WATERTIGHT SLEEVE 86 SEAL (TYP.) -REMOVE EXISTING ORGANIC - WATER TIGHT AND THAT INLET AND OUTLET BAFFLES ARE IN THE --CHAMBERS SHOULD BE LAID AT THE DRSCHEDULE 40 PVC. INSTALL WITH 1/8 PER FOOT MINIMUM SLOPE - MATERIAL PRIOR TO PLACE. GRADES INDICATED, MAINTAINING SEPTIC TANK NOTES SYSTEM INSTALLATION NOTES /�//��777, 65-84"' - GRAY SILT LOAM (DAMP) �� �A �A ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE MOTTLING NOTED ® 24" - - ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT NEW YORK STATE PRECAST DEPARTMENT OF HEALTH AND SHALL BE OF WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS SITE SOILS CONCRETE ENTERPRISES OR AS MANUFACTURED BY UTOPIA EQUIVALENT. AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED CHAMBERS HAVE BEEN INSTALLED. SITE SOILS DATA FROM FROM "REPLACEMENT WASTEWATER TUBING IN SEPTIC TANK LEACH FIELDS. DISPOSAL SYSTEM, MAX SLOPE 3 i 1 ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND AFTER EXCAVATION OF 22" WIDE TRENCH TO THE DEPTHS REQUIRED, THE 7 TRENCHES AT 50' LONG — 350 LF OVERFILL TO ALLOW AUGUST 2004 AND LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. REVISED 11/24/04. OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONESHALL BE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND RAKED IN FILL MATERIAL IS TO BE MECHANICALLY STABILIZED WITH TRACKED EQUIPMENT PLACED AS ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. IN 6" LIFTS PRIOR TO INSTALLATION OF TRENCHES. � NECESSARY TO ACHIEVE A STABLE BASE. STONES OVER 3" (-3) 0-8" - DARK BROWN TOPSOIL T r \ SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF PLACEMENT OF OPEN—BOTTOM GRAVELLESS CHAMBERS SHALL BE AS SHOWN, PERCOLATION TESTS EXTRA HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL - AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS 4" EFFLUENT SEWER TO MAY BE NATIVE MATERIAL OR OTHER MATERIAL WHICH IS NOT NECESSARILY .LOADING. PT -1 AND WASTE MATERIAL IN THE ABSORPTION TRENCHES. SYSTEM FILL. LL STABILIZED PERCOLATION RATE: USE SPEED LEVELERS TO 2"MIN. 3.0 GPM MAX. FAUCETS) 17 I'.. �r�„ EXISTING TANKS TO BE REUSED ARE TO BE PUMPED OPEN—BOTTOM GRAVELLESS CHAMBERS SHALL BE INSTALLED IN ACCORDANCE "- - VERIFIED THAT ALL .AND PENETRATIONS AND TANK STRUCTURE ARE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. - -REMOVE EXISTING ORGANIC - WATER TIGHT AND THAT INLET AND OUTLET BAFFLES ARE IN THE --CHAMBERS SHOULD BE LAID AT THE DRSCHEDULE 40 PVC. INSTALL WITH 1/8 PER FOOT MINIMUM SLOPE - MATERIAL PRIOR TO PLACE. GRADES INDICATED, MAINTAINING - PLACING SYSTEM FILL STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR /�//��777, 65-84"' - GRAY SILT LOAM (DAMP) �� �A �A ALL JOINTS MUST BE SEALED. OTHER UNSUITABLE CONDITIONS, - MOTTLING NOTED ® 24" - - ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT MIRAFI 140N OR EQUIVALENT. TP -2 SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. - SITE SOILS DATA DO NOT USE HEAVY EQUIPMENT WITHIN THE ..ABSORPTION AREA AFTER DATA TANK ACCESS COVER A.ne� V 1LJ CHAMBERS HAVE BEEN INSTALLED. SITE SOILS DATA FROM FROM "REPLACEMENT WASTEWATER . . -- � BUILDING SEWER PIPE ,. 4: PIPING TO BE 4' SDR DISPOSAL SYSTEM, THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT ALEXANDER WASTEWATER" BY JTED �` - ..k - MARTIN ENGINEER', DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC PLLC OF GLENS FALLS, NY DATED 7 TRENCHES AT 50' LONG — 350 LF OVERFILL TO ALLOW AUGUST 2004 AND LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. REVISED 11/24/04. IN GROUND 8" MIN. FOR SETTLEMENT TEST PITS' FILL MATERIAL IS TO BE MECHANICALLY STABILIZED WITH TRACKED EQUIPMENT ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE IN 6" LIFTS PRIOR TO INSTALLATION OF TRENCHES. BACKFILL FREE OF TP -1 EXCLUDED FROM THE WASTEWATER SYSTEM, INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF SYSTEM FILL STONES OVER 3" (-3) 0-8" - DARK BROWN TOPSOIL T MATERIAL PRIOR TO TRANSPORTING TO SITE. 6 STONE DEPTH 22" - ABSORPTION NTS SUGGESTED: POLYETHY EXTENSION TO GRADE TAMPER RESISTANT AC VER (NON TRAFFIC ;Ah 8-32" - LIGHT BROWN SAND LOAM (MOTTLING ® 24") HIS DESIGN IS SUBJECT TO STATE AND LOCAL APPROVALS.. DRSCHEDULE 40 PVC. INSTALL WITH 1/8 PER FOOT MINIMUM SLOPE - �/ C DISTRIBUTION BOX DC,TAIL 32-65" - GRAY BAND LOAM WITHMIXED COBBLES - FILTER FABRIC TRENCH LENGTH REQUIRED = 352 LF /�//��777, 65-84"' - GRAY SILT LOAM (DAMP) �� �A �A FILL MATERIAL NATES FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MOTTLING NOTED ® 24" - ABSORPTION FIELD "SYSTEM FILL" MATERIAL SHALL BE SAND OR SANDY LOAM MIRAFI 140N OR EQUIVALENT. TP -2 WITH. IN-PLACE PERCOLATION RATE OF 2-5 MIN/INCH, AND CONTAINING N0. 0-8". - DARK BROWN TOPSOIL - ORGANIC MATERIAL OR OBJECTS OVER 2"" IN SIZE. SYSTEM FILL MATERIAL TANK ACCESS COVER A.ne� V 8-24" - LIGHT BROWN SAND LOAM (MOTTLING ® 24") SHALL BE INSTALLED TO PROVIDE MINIMUM OF TWO FEET OF SEPARATION 24-65" - LIGHT BROWN SILT LOAM BETWEEN SEASONAL HIGH GROUNDWATER TABLE AND BOTTOM OF ABSORPTION . . -- � BUILDING SEWER PIPE ,. 4: PIPING TO BE 4' SDR 65-84" = GRAY SILT LOAM (DAMP) TRENCHES. ONLY USABLE FILL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION �` - ..k f FIELD AND TAPER AREAS. 7 TRENCHES AT 50' LONG — 350 LF -BOULDER LAVE REFUSAL @ 84"' FOOT MINIMUM SLOPE. IN GROUND 8" MIN. - TP -3 FILL MATERIAL IS TO BE MECHANICALLY STABILIZED WITH TRACKED EQUIPMENT 0-8" - DARK BROWN TOPSOIL IN 6" LIFTS PRIOR TO INSTALLATION OF TRENCHES. 4" A4URFUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND 8-32"" - LIGHT BROWN SAND LOAM (MOTTLING ® 26") INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF SYSTEM FILL SILT STOP EMBED ,: 32-48" - GRA' SAND LOAM MATERIAL PRIOR TO TRANSPORTING TO SITE. MIN. SLOPE12" 5EXISTING 48-84" - GRA SILT LOAM (DAMP) �a„n PERCOLATION TESTS FILL REQUIRED TO PROVIDE COVER OF SEPTIC TANK AND HOUSE SEWER PIPE WASTEWATER SYSTEM DESIGN ry 4" EFFLUENT SEWER TO MAY BE NATIVE MATERIAL OR OTHER MATERIAL WHICH IS NOT NECESSARILY 7 BEDROOM BED & BREAKFAST & HOME BAKERY PT -1 PUMP STATION SYSTEM FILL. WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, STABILIZED PERCOLATION RATE: USE SPEED LEVELERS TO 2"MIN. 4ER WIDTH TRENCH AGGREGATE ABSORPTION 2 MIN. 48 SEC. PER INCH PT -2 SYSTEM MATERIAL SPECIFICATIONS L / SECTION STABILIZED PERCOLATION RATE: ABSORPTION TRENCH AGGREGATE pF�/'I 1 TION 9 MIN. 32 SEC. PER INCH STONE IS TO BE 3/4" TO 1-1/2' WASHED STONE. X91. PT -3 _ BACKFILL MATERIAL STABILIZED PERCOLATION RATE: BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH NO PARTICLES 1, MIN. 9 SEC. PER INCH GREATER THAN 3" (-3). EFFLUENT SEWER PIPE PIPING TO BE 4 S 18" MIN LIQUID DEPTH 30" MIN. 60" MAX. MINIMUM 2X WIG MAXIMUM 4X WIC 1000 GALLON PRECAST CONCRETE SEPTIC TANA SEPTIC TANK DETAIL PERSI 1 yOTE DRSCHEDULE 40 PVC. INSTALL WITH 1/8 PER FOOT MINIMUM SLOPE - �/ C DISTRIBUTION BOX DC,TAIL ABSORPTION AREA REQUIRED = 704 SF - ALL CONSTRUCTION WASTE FILTER FABRIC TRENCH LENGTH REQUIRED = 352 LF :SUGGESTED: INSTALL POLYLOK - MATERIAL SHALL BE DISPOSED -- FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE PL122 FILTER SUCH THAT IT IS OF IN A LEGAL MANNER. MIRAFI 140N OR EQUIVALENT. READILY ACCESSIBLE THROUGH FORCEMAIN TANK ACCESS COVER A.ne� V :.. ,.� PIPING TO BE 1-114" PE. 11 HDPE. , •",v Y, ,�,. , opm- f , _; E '' '�:.� . . -- � BUILDING SEWER PIPE ,. 4: PIPING TO BE 4' SDR PUMP STATION DOSE VOLUME .. ' �` - ..k -35 OR SCHEDULE 40 PVC. INSTALL WITH 1/4" PER S£ 7 TRENCHES AT 50' LONG — 350 LF FOOT MINIMUM SLOPE. IN GROUND 8" MIN. .65 GAL/LF = 228 GAL X,. 75 — 171 GAL TOPSOILPLACE VOLUME OF DOSE TO BE 170± GALLONS ,! 4" A4URFUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND 1/8" PER FOOT SILT STOP EMBED ,: ESTABLISH MIN. SLOPE12" 5EXISTING TRANSITION TO 4' MIN. COVER �a„n o DISTRIBUTION BOX OUTSIDE of D -Box WASTEWATER SYSTEM DESIGN ry 4" EFFLUENT SEWER TO V 7 BEDROOM BED & BREAKFAST & HOME BAKERY PUMP STATION FORCEMAIN BAFFLE WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, USE SPEED LEVELERS TO 2"MIN. 3.0 GPM MAX. FAUCETS) - ASSURE ALL -OUTLETS ARE AT 2"MIN.. DROP DESIGN FLOW — 110 GPD/BEDROOM + 75 GPD (BAKERY) EXACTLY THE SAME f71 VA BETWEEN INVERTS DESIGN FLOW — 845 GPD 4" PVC SDR -35 SOLID HEADER SEPTIC TANK — TWO 1,000 GAL PRECAST CONCRETE IN SERIES TO ABSORPTION TRENCH, 1/8" )` LEACH FIELD — OPEN—BOTTOM GRAVELLESS CHAMBERS PER FOOT MIN SLOPE ) DESIGN PERCOLATION RATE= 1-5 MIN/IN 1000 GALLON PRECAST CONCRETE SEPTIC TANA SEPTIC TANK DETAIL PERSI 36" FENCE POST APPLICATION RATE - 1.2 GPD SF � �/ C DISTRIBUTION BOX DC,TAIL ABSORPTION AREA REQUIRED = 704 SF NTS TRENCH LENGTH REQUIRED = 352 LF EXISTING TRENCH LENGTH 150 LF 'ADDITIONAL TRENCH LENGTH -REQUIRED = 202 LF.. INTO GROUND _. 25% REDUCTION WITH 22'W CHAMBERS = 152 LF ADDITIONAL REQUIRED ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED 4 ADDITIONAL TRENCHES AT 50' LONG,PROPOSED = 200 LF ADDITIONAL PUMP STATION EXISTING 1,000 GAL PRECAST CONCRETE PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. PUMP STATION DOSE VOLUME .. ' S£ 7 TRENCHES AT 50' LONG — 350 LF IN GROUND 8" MIN. .65 GAL/LF = 228 GAL X,. 75 — 171 GAL VOLUME OF DOSE TO BE 170± GALLONS ,! POTABLE WATER SUPPLY IS MUNICIPAL SUPPLY SILT STOP EMBED ,: MAINTAINATER �a„n IN GROUND 8" MIN., - AND ND1 WASTEWATERESYSTEM COMPONENTS ry 36" FENCE POST TAX MAP.# 297.I0 -I-52 DRIVEN MINIMUM 16" INTO GROUND ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. SILT STOP EMBED 36" FENCE POST IN GROUND 8" MIN. ? ,! SILT STOP EMBED ,: o IN GROUND 8" MIN., V 1 REVISED PER OWNER 1],3129113UNDISTURBEDGROUND0 ISSUED FOR SITE PLAN REVIEW No. Date 2NE—SOIL BACKFILL SECTION DETAILS ared for., IMENT CONTROL FENCE DETAIL Brittany &pMegan Alexander Dig OSafely. New' -York 667 Ridge Road El Can Before You Dig Town of Queensbury, Warren County, NY 1D Wait The Required Time El Confirm Utility Response Drawn: DAG c+ - EDRespectTheMarks Checked: GTH Scale: NOTED Date: 01/02/2013 EI Dig with care 169 Haviland Road 800.962-7962 ��� Queensbury, NY 12804 29669-01-S3 www.digsefelynewyork.com (518) 745-0307 Phone Hutchins Engineering (518) 745-0308 Fax