Loading...
2014-246 TOWN OF QUEENSBURY WOO 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20140246 Date Issued: Tuesday, March 15, 2016 This is to certify that work requested to be done as shown by Permit Number P20140246 has been completed. Tax Map Number: 523400-296-015-0001-004-000-0000 Location: 69 COUNTRY CLUB Rd Owner: JEFFREY BEATTIE Applicant: JEFFREY BEATTIE This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the /J property owner of the responsibility for compliance with Site Plan, �d `' Variance, or other issues and conditions as a result of approvals by the •��� Director of Building& Code nforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY `�* 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130246 Application Number: A20130246 Tax Map No: 523400-278-000-0001-057-000-0000 Permission is hereby granted to: LAWRENCE&FRANCES EICHLER For property located at: . 1323 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: LAWRENCE &FRANCES EICHLEF Porch $10,000.00 1323 BAY Rd Total Value $10,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency JERROLD A CAMERON 518-623-2177 OR 518-423-9488 CELL 35 MARBLE OUARRY Rd WARRENSBURG NY 12885-0000 • Plans&Specifications 2013-246 PORCH - (3 season) 300 sq ft Area Variance for front yard setback Approved AV 44-2013 $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, August 22, 2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of ueen ury; hu. i • f• _ 1 st 22,2013 dol SIGNED BY \ for the Town of Queensbury. Director of Building& Code Enforcement Office Use Only Town of Queensbury Building & Codes Received: SEPTIC DISPOSAL PERMIT Tax Map ID: Permit No.: A permit must be obtained before beginning construction Permit Fee: $ A7:------- Approvals: Applicant: \I ec'J / "Ctrt I e InstallerlBuilder Address: 6 q (!p 41 /Nt1 y C6%!lg Al Address q Phone: 3 E / 3 z?Z 3 Phone Owner: 1) ri ocation of Installation -CJ LL ; ��/A 6j ki- Address: II f�t n (� ; u : 2014 I 1 j I Phone _ TOWN 5"il--1i1E N- '-- Contact Person for Building&Code Compliance: ���Gt�1G& enDE�C Day Phone: Residence Information: Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow 1980 or older x 150 = Garbage Grinder installed? 1981 —1991 x 130 = Spa or Hot Tub Installed? 1992—Present 3 d x 110 = 3 73 '2 Parcel Information: Topography ,%Flat Rolling Step Slope %Slope Soil Nature Sand (--"t.oam Clay Other Groundwater At what depth? Bedrock/Impervious Material At whit depth? Domestic Water Supply V Municipal Well(if well,water supply from any septic system absorption is ft.) Percolation Test Rate- per minute per inch(Test to be completed by a licensed professional engineer or architect) Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Tank size gallon(minimum size 1,000 gallons),add 250 gallons to size of septic tank for each garbage grinder,spa or whirlpool tub System Type: Absorption Field(with#2 stone) Total length ft. Each trench X Seepage Pit(S)(with#3 stone) How many? Size? Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size? #of tanks? NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified Electrical form on Town website; 2) Effective as of March 23, 2006 Septic System-As Built Plot Plan: The Building Department will no longer allow systems to be covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed system must match the septic system layout on file. There will be no exceptions. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. ✓I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. I Print Name: '�1 an��fe� fe Date: C —Z r l Signature: k Date: .i `-Z ~ l I Town of Queensbury Buil ng Codes Septic Disposal Permit 518-761-8256 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: ctACM C"-' Inspected on: IA Location: (Sick GD�� KIN-C,a C.� U 13 �d Arrive: GAMY ..m. 'p.m. Permit No.: \ Z1�t� 1 Inspector's Initials: Co ents and/or dia.ram Soil Type: Sand/Loam I Clay Type of Water: Municipal/Well Water Waterline separation distance ft. 1 ,� Well separation distance ft. �SS G�— �k� l Other wells: ft. Well Casing Length 50'+I- _Y_N_NIA [150'to well required if NO] VVIS\A Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: _Y_N End Cap Y N Inlet/Outlet Pipes&Baffles _Y N Manholes 12"or less below grade _Y N [provide extension collar if Yes] _Y N " t Location/Separations I Foundation to tank ft. Foundation to absorption ft. Separation of Pits Conforms as per Plot Plan Y_N Engineer Report and As-Built _N ETU Maintenance Contract provided Y N Location of S stem on Pro.: : Front Rear Left Side Right Side Middle Front Middle Rear S stem Use St.tu . V Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report TOWN OF QUEENSBURY 1� 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 s Community Development- Building&Codes (518) 761-8256 Inspections per Permit Permit # P20140246 Inspection Date Inspection Type Approved/Denied Comments Permit Type Person Responsible 06/07/2014 Septic Septic Alteration Residential JOHN O'BRIEN Denied 2014-246 met w/Jeff to go over replacement system. Will need to have a deep holt test&percolation test. Replacement system will be in back yard. It will have to be a shallow trench. 06/09/2014 Miscellaneous Septic Alteration Residential STAFF Misc 2014-246 permit app rec'd 06/09/2014 Miscellaneous Septic Alteration Residential STAFF Misc 2014-246 permit issued 07/01/2014 Septic Septic Alteration Residential JOHN O'BRIEN Denied 2014-246 9 am not ready-will recheck this afternoon 07/01/2014 Septic Septic Alteration Residential JOHN O'BRIEN Partial 2014-246 1:05 pm OK to backfill Need as-built from Ethan Hall RUCINSKI HALL ARCHITECTURE �P�¢,� Ronald Richard Rucinski �J Ethan Peter Hall G`� G 134 Dix Avenue J G Glens Falls NY 12801 Q. Voice 518 741 0268 Fax 518 741 0274 Email ephall@nycap.rr.com Septic Install for Beattie Residence —69 Country Club Road June 2014 John O'Brien —Town of Queensbury Building Department 742 Bay Road Queensbury NY 12804 Re: Septic Installation for Beattie Residence—69 Country Club Road John. At the above referenced project location I observed the installation of the sewage disposal system including the septic tank, distribution box and tile field laterals prior to back fill. All items appear to be installed in accordance with the construction documents and are acceptable to this office. If there are any additional questions please call to discuss. Regards, 4a, ! ? Ethan Peter Hall _ ,. i Architect ��70 ~rteB . ; t Y:1Beattie Septic\Letter June 2015.doc 1 Septic Inspection Re• • Office No. (518) 761-8256 Date Ins - ion rte- . -ivy.: Queensbury Building &Code Enforcement Arrive: . /!b j� �D- 8-rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Ini I. ff . NAME: Bi'H 1 1 a `I PER. NO.: \L\-vAy LOCATION: 9 Com\)fJ ,'( CA ocb RD INS'- ON: .7 —1 — 1 RECHECK: Comments and/or diagram Soil Type: Sand/ Loam / Clay , Type of Water: Municipal / Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches _ _ _ ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: _Y_N End Cap _Y_ N Inlet/Outlet Pipes&Baffles _Y N Manholes 12"or less below grade _Y_ N KJb—C- \ _AD \ LI— [provide extension collar if Yes] Y N ,,I ,,\ Location / Separations -TO, kt, Pt FT o Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan _Y_ N Engineer Report and As-Built _Y N ETU Maintenance Contract Y_ N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: proved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report03 29 10.doc Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: Geo_ A71-j" Inspected on: ��� Location: (/ `l C O ( f 4Y Arrive: -Ati fir a.m.I ISO Permit No.: / /— e<A, Inspector's Initials: om' ents and/or dia•ram Soil Type: San• •. lay Type of Water ell Water Waterline sep. ation distance 1c ft. Well separation distance ft. Other wells: ft. Well Casing Length 50'+/- Y__N N/A [150'to well required if NO] Absorption Field: Total length Z.Off) ft. Length of each trench 46)— oft. Depth of trenches �Qe� ft. � *a2._"-V‘-‘tE17P ,5 Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank y v1 Tank to Distribution Box y" Distribution Box to Field/Pit Lk" b c • ytQ\.,7F Opening Sealed: Y N End Cap N E1J(7 uouVEP tot C\-le �E � Inlet/Outlet Pipes&Baffles Y Manholes 12"or less below gradeN 40\)/:-A-P)� Gt�t�tJ��D f Fti��sQ [provide extension collar if Yes] Y N EEC) V,-1)SEV._ ,-co `\ -\ ( V�N 6 cAskw Location/Separations Foundation to tank AO ft. Foundation to absorption 7_13 ft. + Separation of Pits Vm TD -1`—F t V `-- Conforms as per Plot Plan Y Engineer Report and As-Built Y CE ) ND-9-)131\::-1-( FVANA ETU Maintenance Contract provided Y N Location of System on Property: Front Rear Left SideRight Sideddle Front Middle System Use Statu . Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report Septic Inspection Report Office No. (518) 761-8256 Date Inspection r;•ues - : v : Queensbury Building &Code Enforcement Arrive: 1C)---Z1) •m'., D rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: .0 o NAME: C C))EtkTT1 F P'• NO.: \ a11K1 K LOCATION: �D° C_C)3 -� \-)3 K) I► ECT ON: (p -7 I y RECHECK: Comments and/or diagram Soil Type: Sand / Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. h ET I 17E_F Well separation distance ft. Other wells: ft. c� Well Casing Length 5(Y + / - Y N N/A C) e- [150'to well required if NO] 1b E-V1 \ —T-C) Absorption Field: Total length ft. H ' \ 0 EE'S) -TFIST Length of each trench ft. Depth of trenches ft. , Size of Stone c� Seepage Pits: Number `1h �� &1�� Size: x \t� �C� `S f¢) \T Stone Size: \--\ Piping Size Type �L � Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: _Y_ N End Cap _Y_ N Inlet/Outlet Pipes&Baffles ._ Y_-._.. N Manholes 12"or less below grade _Y_ N [provide extension collar if Yes] Y_ N Location/ Separations Foundation to tank ft. Foundation to absorption _ _ ft. Separation of Pits ft. Conforms as per Plot Plan Y^ N Engineer Report and As-Built _Y_ N ETU Maintenance Contract _Y_ N provided Location of System on Property: Front •ear Left Side Right Side Middle Front Middle Rear S stem Use S S . us: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report03 29 10.doc Charles H. Maine, Soil Scientist 32 Terrace Road Queensbury, NY 12804 June 5, 2014 Jeff Beattie 69 Country Club Road Queensbury, NY 12804 Re : Jeff Beattie Property, 69 Country Club Road, Town of Queensbury, Warren County, New York. On June 3, 2014 I examined a soil test pit and performed a soil perculation test on the above property. Listed below are my observations : 0 - 8 Inches. topsoil 8 -29 Inches, silt loam 29-69 Inches, silt, mottling starts 29 inches Soil perculation rate at 24 inches is seven minutes and 35 seconds per inch. Soils observed in the area of this soil test pit are deep, silty soils. Seasonal high ground water table is noted by the depth to mottling in the soil test pit. If you have any questions about the above soil information, feel free to contact me. =rte, Charles H. Maine Soil Scientist Charles H. Maine, Soil Scientist 32 Terrace Road Queensbury, NY 12804 June 5, 2014 Jeff Beattie 69 Country Club Road Queensbury, NY 12804 Re: Jeff Beattie Property, 69 Country Club Road, Town of Queensbury, Warren County, New York. On June 3, 2014 I examined a soil test pit and performed a soil perculation test on the above property. Listed below are my observations: 0 - 8 Inches. topsoil 8 -29 Inches, silt loam 29-69 Inches, silt, mottling starts 29 inches Soil perculation rate at 24 inches is seven minutes and 35 seconds per inch. Soils observed in the area of this soil test pit are deep, silty soils . Seasonal high ground water table is noted by the depth to mottling in the soil test pit. If you have any questions about the above soil information, feel free to contact me. Charles H. Maine Soil Scientist SCHEMATIC PLAN SEPTIC SYSTEM DESIGN DESIGN FLOW - NEW 3 BEDROOM HOUSE WITH NEW STANDARD WATER SAVING FIXTURES AT 110 gpd PER BEDROOM = 330 gpd SEPTIC TANK - 1,000 gal TANK REQUIRED- REUSE EXISTING ABSORPTION FIELD - 8 to 10 MIN. PERC. RATE - APPLICATION RATE 0.90 gal/day/sq. ft. - 330 gpd DIVIDED BY 0.90 gal/day/sq. ft. = 367 sq. ft. OF TRENCH REQ'D AT 2' WIDTH PER LATERAL. USE 4 LATERALS AT 50' = 400 sq. ft. OF APPLICATION AREA. SCHEMATIC SECTION ALL LATERALS TO BE SET ACROSS THE EXISTING SLOPE. STEP LATERALS AS NECESSARY I I \I 502.53' m FROM SEPTIC TANK UP2E D INLET BAFFLE 4" PVC - --CONCRETE OR STONE MARKER ABOVE ALL BURIED COVERS RECOMMENDED. 12" MINER ALL STRUCTURES #1 DISTRIBUTION BOX �BY FORT MILLER OR EQUAL iv°off -ALL OUTLET INVERTS TO BE SET AT PEA:---yEXACTLY THE SAME GRAVEL ELEVATION. (USE OF SPEED LEVELERS ` ENCOURAGED) DISTRIBUTION BOX N.T.S. I I 1 � GO I 0 TP -1 PROVIDED BY CHARLES H. MAINE 5 JUNE 2014 0- 8 INCHES, TOPSOIL B-29 INCITES, SILT LOAM 29-69 INCHES SILT MOTTLING AT 29 INCHES `I c I' PT -1 ' PROVIDED BY `CHARLES H. MAINE 5 JUNE 2014 STABALIZED PERCOLATION RATE S' 7'-35" PER INCH I � I 1 J� I ^ I � � 12" MAX. 2" MIN. 6"E N.T.S. 4"0 PERFORATED PLASTIC PIPE MAXIMUM SLOPE 1/16" PER FOOT, CAP ALL ENDS. FILL IMATERIAL TO BE CLEAN SANDY LOAM WITH A PERCOLATION RATE OF BETVlEEN 10 AND '15 MIN FOR 1". I THE BEST DESIGNED AND INSTALLED SEPTIC SYSTEM WILL EVENTUALLY FAIL TO FUNCTION PROPERLY WITHOUT PERIODIC MAINTENANCE. INADEQUATE SEPTIC TANK MAINTENANCE CAN RESULT IN CLOGGING OF THE TANK AND SEWAGE BACKUP INTO THE HOME AND/OR SEWAGE OVERFLOW ONTO THE GROUND SURFACE. FAILURE TO PERIODICALLY CLEAN A SEPTIC TANK COMMONLY RESULTS IN CLOGGING OF SOIL SURROUNDING -THE ABSORPTION FILED BY OVERFLOWING SOLIDS NOT' REMOVED BY THIP SEPTIC TANK. THIS DESIGN IS INTENDED TO PROVIDE SUBSURFACE SEWAGE DISPOSAL ONLY FOR TTIE LOT IF IS SHOWN ON NO ADDITIONS INVOLVING LIVING OR SLEEPING AREAS MAY BE ADDED TO THIS BUILDING WITHOUT THE APPROVAL OF THE BOARD OF SEWAGE DISPOSAL GRADED SO AS TO DIVERT ANY RUN–OFF AWAY FROM IH -SYSTEM NOTES SIGNATURE EX ON THIS PLAN SPECIFICALLY EXCLUDES CERTIFICATION FOR FUTURE ANSION OR REPLACEMENT. THEPE SHALL BE NO CHANGE ON THESE PLANS IN ADVANCE OF OR DURING NO�GARBAGE t GRINDERS ALLOWED UNLESS INSTALLED IN INITIAL CONSTRUCTION OF CONSTRUCTION, WITHOUT PRIOR APPROVAL OF THE DESIGN PROFESSIONAL OR THE o THE TOWN BUILDING INSPECTOR. w 'a GA LONS. DESIGN, CONSTRUCTION, MATERIAL STANDARDS AND INSPECTION REQUIREMENTS D -10 N SHALL COMPLY WI1H THE LATEST EDITIONS) OF THE NEW YORK STATE f- DWELLING IS HAVE WATER SAVING FIXTURES, INCLUDING BUT NO LIMITED TO: Z=` =z DEPARTMENT OF HEALTHWASTEWATER TREATMENT STANDARDS -INDIVIDUAL Q LESS �z � HOUSEHOLD SYSTEMS APPENDIX 75-A. I I11 < Z w B SEPTIC TANIC TO BE SET- ON A LAYER OF COMPACTED PEA STONE OR WASHED [ to r w o GRAVEL. TANK SHALL BE INSPECTED ANNUALLY TO DETERMINE SCUM AND SLUDGE BY THE HOMEOWNER A � < o OR QUALIFIED SEWAGE HAULER. THE r��T� SEP'NC TANK TO HAVE SCH 40 PVC "T" AT INLET AND OUTLET. AMOUNT OF BUILD-UP NOTED AT EACH INSPECTION SHOULD BE RECORDED ANDi �I o – If UET 12" BELOW FLOW LINE, 6" ABOVE FLOW LINEa MA�N',TAINED_BY THE HOMEOWNER. THE TANK SHALL BE PUMPED WHENEVER THE Zto - OUTLET 14" BELOW FLOW LINE, 6" ABOVE FLOW LINE BOTTOM E J 0 o wow 3" AIR SPACE ABOVE "T" TO TOP OF TANK r( BAFFLE E 4 s a CH�T4011R z to N OU i= 0 NO ROOF, FUO'TING, FLOOR, COOLING WATER, BACKWASH DRAINS, ETC., SHALL BE SH _ 00,6 � o o CONI,JECTED TO TTIE SEWAGE SYSTEM. NO SUMP PUMP, CONDENSATE, WATER D o __ U SOFTENER, SPAS, OR HOT TUBS SHALL BE DRAINED INTO THE SYSTEM. WHPMSEPTIC s >; c z N ¢fn o THERE SHALL BE NO CONSTRUCTION OF SEPTIC SYSTEMS WITHIN 100' OFA V t+ a e00D®� <� CLASSIFIED BODY OF WATER. C, a o n to t< a (KED OR BROKEN LINES MUST BE REPAIRED OR REPLACED. AN, jCOMPANY EMPLOYED TO CLEAN AND SERVICE THE SEPTIC TANK MUST BE A HOUSE TO SEPTIC TANK: 4"0 PVC SCHEDULE 40 WITH TIGHT JOINTS, MINIMUMCA 0 'oo E ~ SLOPE 1/4" PER FOOT. SEPTIC TANK 1.0 DISTRIBUTION BOX: 4"0 PVC SDR 26 P1 1 vo DISINFECTED AFTER BEING PUMPED OUT. l NTH r TIGHT JOINTS, MINIMUM PITCH 1/8" PER FOOT. SANITARY DISPOSAL FIELD: vo LIC l mm 4"0 PERFORATED PLASTIC PIPE MAXIMUM SLOPE 1/16" PER FOOT, CAP ALL ENDS. FILL IMATERIAL TO BE CLEAN SANDY LOAM WITH A PERCOLATION RATE OF BETVlEEN 10 AND '15 MIN FOR 1". I THE BEST DESIGNED AND INSTALLED SEPTIC SYSTEM WILL EVENTUALLY FAIL TO FUNCTION PROPERLY WITHOUT PERIODIC MAINTENANCE. INADEQUATE SEPTIC TANK MAINTENANCE CAN RESULT IN CLOGGING OF THE TANK AND SEWAGE BACKUP INTO THE HOME AND/OR SEWAGE OVERFLOW ONTO THE GROUND SURFACE. FAILURE TO PERIODICALLY CLEAN A SEPTIC TANK COMMONLY RESULTS IN CLOGGING OF SOIL SURROUNDING -THE ABSORPTION FILED BY OVERFLOWING SOLIDS NOT' REMOVED BY THIP SEPTIC TANK. THIS DESIGN IS INTENDED TO PROVIDE SUBSURFACE SEWAGE DISPOSAL ONLY FOR TTIE LOT IF IS SHOWN ON NO ADDITIONS INVOLVING LIVING OR SLEEPING AREAS MAY BE ADDED TO THIS BUILDING WITHOUT THE APPROVAL OF THE BOARD OF GRADE SHOULD BE GRADED SO AS TO DIVERT ANY RUN–OFF AWAY FROM IH HEALTH AND REDESIGN OF THE SUBSURFACE DISPOSAL SYSTEM. TTIE SEAL AND SIGNATURE EX ON THIS PLAN SPECIFICALLY EXCLUDES CERTIFICATION FOR FUTURE ANSION OR REPLACEMENT. NO�GARBAGE t GRINDERS ALLOWED UNLESS INSTALLED IN INITIAL CONSTRUCTION OF C THE HOME AND THE SEPTIC TANK SIZE IS INCREASED BY A MINIMUM OF 2501 GA LONS. -10 DWELLING IS HAVE WATER SAVING FIXTURES, INCLUDING BUT NO LIMITED TO: LESS THAN ,2 GPM SHOWER HEADS, 'LOW WA1ER USE TOILETS, SINK FLOW REPT E-W; RICIORS. OBSERV,TER CONSERVATION PRACTICES. SEPTIC ACCUMULATION TANK SHALL BE INSPECTED ANNUALLY TO DETERMINE SCUM AND SLUDGE BY THE HOMEOWNER A � p OR QUALIFIED SEWAGE HAULER. THE r��T� 00 AMOUNT OF BUILD-UP NOTED AT EACH INSPECTION SHOULD BE RECORDED ANDi �I ® N MA�N',TAINED_BY THE HOMEOWNER. THE TANK SHALL BE PUMPED WHENEVER THE BOTTOM OF THE SCUM LAYER IS WITHIN 3" OF THE BOTTOM OF THE OUTLET/ "T". • BAFFLE OR SANITARY THE PUMP700T CLEARANCES ALSO APPLY TO ANY CH�T4011R IN MULTI -COMPARTMENT TANKS OR TO TANKS IN SERIES. MOST TANKS SH ULD BE PUMPED OUT EVERY TWO TO THREE YEARS. 1 1 ✓' U WHPMSEPTIC TANK IS PUMPED, THE SEPTIC TANK, BAFFLES/TEES, HOUSE SEWER ��f-1 CONNEC'IION DETERIORATED AND OUTLET SHALL BE INSPECTED. BAFFLES/TEES THAT HAVE AND NO LONGER PERFORM AS DESIGNED SHALL BE REPLACED. CR (KED OR BROKEN LINES MUST BE REPAIRED OR REPLACED. AN, jCOMPANY EMPLOYED TO CLEAN AND SERVICE THE SEPTIC TANK MUST BE A DEC,PERMITTED SEPTAGE HAULER. SEPTIC TANKS SHOULD NOT BE WASHED OR P1 1 vo DISINFECTED AFTER BEING PUMPED OUT. l VJ Q vo LIC l U SEP TANK ADDITIVES SHALL NO'T BE USED IN THE SEPTIC SYSTEM.. ADDITIVES N AREIUNNECESSARY FOR THE PROPER OPERATION OF HOUSEHOLD SYSTEMS AND Q MAYICAUSE THE SLUDGE AND SCUM IN THE SEPTIC TANK TO BE DISCHARGED \p (y INTO THE ABSORPTION FIELD, RESULTING IN PREMATURE FAILURE. DO tJOT DISPOSE OF EXCESS HOUSEHOLD GREASE OR FAT INTO THE SEP11C SY TEM. DO NOT POUR OR DUMP ABNORMAL AMOUNTS OF HOUSEHOLD CHEMICALS 'TOILETS. H --I OR�ILEANERS INTO SINKS OR WHEIIEVER SEPTIC TANKS ARE 10 BE 'ABANDONED IN THE EVENT OF PUBLIC SEWERS ARE INSTALLED TO HANDLE HOUSEHOLD WASTES, THE TANKS SHOULD BE RE 6VED OR PUMPED OUT AND FILLED WITH SOIL TO PREVENT FUTURE CAVE -1N. NO, ITHICULAR TRAFFIC OR PARKING SHALL BE ALLOWED ON ANY PORTION OF THF (ABSORPTION FIELD OR THE SEWAGE DISPOSAL SYSTEM. FINAL GRADE SHOULD BE GRADED SO AS TO DIVERT ANY RUN–OFF AWAY FROM IH (ABSORPTION FIELD. BARRIER MATERIAL 1 -1 Asv11�'U?e . \ SLOPE \-4" PERFORATED PVC LATER/ SLOPE 1/16"-1/32" PER FT. NOTES: 1. END OF ALL DISTRIBUTOR PIPES MUST BE PLUGGED UNLESS INTERCONNECTED. 2. ALL LATERALS TO BE OF EQUAL LENGTH. CAD FILE NAME BEATT I E\SI TEPLAN\C-1 SCALE AS NOTED DRAWN BY MACKENZIE PELTON DRAWING TITLE EXISTING AND PROPOSED PLOT PLANS AND DETAILS DRAWING No. C-1 „}t CSF ti U % II w rA!Y 581 30 52-E N F ho” 502.53. m u,W /) - `\\ N c a� cz AREA k a 49,528 sq.ft. b G1.14 acres 1!> r GRF 94.82 48q.63- GRF 109,10 CIRF N81 O413'W 105, T� 61 CIRF V o COO IRS liO ia c� (� W o O� r believe I saw evidence of, SEPTIC PLOT PLAN " I have seen OP 0 S enC°S, etC., I HAVE SEEN OR OBSERVED ALL OOJECIS w all objects such as houses, els, SUCH AS HOUSES, WELLS, TREES, FENCE , Erc shown on this document. I also represent tha „ E SHO' ON THIS DOCU,N c"tT. I H4 E PFS;' NALLY ME URED' iF I, C:�CE`� c r, _ pr,GRAM�� personally measured the distances set forth �� �ap I �- NF l',iE DATE ,IGN URE C.M. CIR e) N `9 have seen a all objects sucl shown on this personally mea