Loading...
2013-201 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERP-"vHFIC ATE OF OCCUPANCY Permit Number: P20130201 Date Issued: Friday, December 20, 2013 This is to certify that work requested to be done as shown by Permit Number P20130201 has been completed. Location: 543 AVIATION Rd Tax Map Number: 523400-302-005-0001-05 1-000-0000 Owner: AFTAB BHATTI Applicant: AFTAB BHATTI This structure may be occupied as a: Commercial Alteration By Order of Town Board RM a\q I a 5, �as TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or j/V t— other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: P20130201 Application Number: A20130201 Tax Map No: 523400-302-005-0001-05 1-000-0000 Permission is hereby granted to: AFTAB BHATTI For property located at: 543 AVIATION Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: AFTAB BHATTI Commercial Alteration $2,000.00 547 AVIATION Rd Total value QUEENSBURY,NY 12804-0000 $2,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2013-201 ECONO LODGE Comm Alt. bathrooms Rms 9219, #125 &#225 r $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, May 16,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Thursday,May 16,2013 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ' oppusua�ow�r . � ��� ^av TAX MAP wo�l��__'_____--___ � ' �/� lE 2013 � . , . . ' FssmPERMIT � ' | . ___ _ _�______ '- �-_ ' . . � (if applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION mSUBJECT TO REVIEW BEFORE ISSUANCE opAVALID PERMIT FOR CONSTRUCTION. Appucawnau/Loem OWNER: xooxEaa: led Aooneoo: r*DNENOS. e 793 PHONE NOS. CONTACT PERSON FOR BUILDING mCODES CO LOCATION oFPROPERTY: R' NO []YES mo /FSO,INDICATE APPLICATION NO.AND DATE 0rAPPROVAL: II PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: LL X SINGLE FAMILY (NO.of UNITS TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED OTHER |rCOMMERCIAL oaINDUSTRIAL-NAME OF BU a|wsSa ESTIMATED CONSTRUCTION uoaT�� puELTYps: HEAT TYPE: 'HOW MANY F|*EpL^Ce(S): AND/onvvoOo3T0veG(a):_______ ZONING CATEGORY: ARE THERE WETLANDS DwTHIS SITE? |oTHIS AHISTORIC SITE? ___ PROPOSED USE opBUILDING onADDITION: ARE THERE STRUCTURES NOT SHOWN ONPLOT PLAN? ARE THERE EASEMENTS VNPROPERTY? ^p/e*cecumwmcaoenanaTc,Aw/|/,mucn*,^+ua/Burning Armfioo'mpxin our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. Signe W 2'AW' 4'0 Director of Building&Codes: 781-8258(for questions regarding Building Permits,construction codes or septic systems) ^ Zoning Administrator, 761-8218(for questions regarding required permits, the permit process, application requirements orhuschedule unappointment) r~~—'---^--'—'—'''—'''^-----'- ,---------'-----------'''—'----''-----� ' . ^ � Permisaion is hereby granted to the above This application/proposed action described � � Applicant to erect or alter the building herein is found to be in accordance with the � � described herein in accordance with said zoning Laws ofthe Town ofQueensbury. | � Application: . . . ^ . . . . � � � � ~ �DA ~~. ~~.'. . ..'.� ' ^ ZONING APPROVAL . �� DATE ' QUESTIONS 7 CALL 761-8256 Oft EMAIL Office Use Only. VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: —Yes w Occupancy Type: Construction Classification: Assembly Occupancy umu: Special Conditions: Town ofQueensbury°Community Development Office°742Bay Road,Queensbury NY 12804 io Report Comm` rcial Final Ins n po Office No.: (518) 761-8256 Date Inspectioryc�q�r s ceiv Queensbury Building &Code Enforcement Arrive: a am 742 Bay Road, Queensbury, NY 12804 Inspector's In' NAME: tLd ( -`" PERMI LOCATION: DATE: COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Th h Roof 6"/Roof Complete Exterior Finish/Grade Com to 6"in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Stop Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft All Doors 36 in.wA ever Handles/Panic Hardware if required Exits At Grade Or Platform 36 w x 44°(lypanopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18' Above Grade Floor Bathroom Wateftht/Other Floors Oka Relief Valve Heat Trap/Water Temp.110 Degrees Maximum Boiler/Fumace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Sup&for Occu /Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/doors > 10%> 1000 sq.ft. %Hour Corridor Doors lit Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dam rs/Fire Doors Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Spam Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si /Shaft Sealed Handica Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters 34 in. Checkout 36" Handicapped Ramp/Handrails Continuous112 in.Beyond[Both sides Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Fk)od Plain certification If As-built SepticSystern Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler 'Building Access AN Sides by 20'1 Driveable Surface 20'wWe Okay To Issue Temp. or Permanent CIO Okay To Issue CIC LABuilding&Codes Forms\Building&Codesllnspection FormslCommeraal Final Inspection Reportdoc Revised January 7,2008 -1 Multiple Dwelling, Hotel, Motel, Apartment Final Inspection Report Office No.: (518)761-8256 Date lnspen re reciv d: Queensbury Building&Code Enforcement Arrive: /'r Depart: am/pm 742 Bay Road,Queensbury, NY 12804 Inspector's I '' s: f I j NAME: &V&D A" ERMIT#: 1 3'o� l nnl V LOCATION: � 3 A Q ta+,p I DATE: I j 3 Y N NA COMMENTS: Chimney Height/ "B" Vent/ Direct Vent Location Plumb Vent Thru Roof Minimum 6" Roof Complete pp Exterior Finish Complete / Finish Grade 6" In 10' Drop �v\ Interior/Exterior Railings 34 Into 38 in. / 36" Landing, Decks, Porches Exterior Handrails, Balconies, Landing 30" Or More Interior Handrails Balconies/ Landing 30" Or More -- Interior Handrails Stairs 1 or More Risers Guardrails 42", Ballisters 4" Minimum Spacing Vestibules For Exit Doors > 3000 sq. ft. _ Doors 36" / Lever Handles � = Headroom 6' 8" on Stairs 4" Bathroom / Kitchen Watertight -- , Smoke Detectors: Every level, Every bedroom Outside every bedroom, Interconnected Battery Backup -�-' Carbon Monoxide Alarm -lowest sleeping level � � Bathroom Fans / PlumbingFixtures Complete Foundation Insulation Fire Separation, 3/4, 1, 2 hr. -'� Fire Walls 1, 2, 3 Hour/ Fire Door 3/4, 1 '/z, 2 Hour Handicapped Accessibility/ Handicapped Parking/Signage Gas Log In Sealed or Glass Enclosure Gas Valve Shut-Off Exposed / Regulator 18" Above Grade ' ge Gas Furnace Shut-Off Within 30 ff. or Within Line Site Oil Furnace Shut-Off at Entrance to Furnace Area Furnace / Hot Water Heater Operating /Fresh Air Intake Low Water Shut-Off for Boiler fr' Relief Valve, Heat Trap /Water ternp 110 Degrees Max. r Garage Fireproofing Complete, Penetration Sealed Furnace In Separate Room / Protected In Garage) ) Light Ventilation per Room /Safety Glazing Attic Access 30" x 20" x 30" H /Crawl Space 18" x 24" / Final Electrical Site Plan/Variance Required Final Survey Plot Plan / Flood Plain Certification, if Reg. As-built Septic System Layout Required Building /Apartment Number on Building or Driveway Build Access All Sides by 20', Driveable Surface 20"Wide Okay To Issue Tem C/O or Permanent CO (circle one) Okay To Issue C/C ; L:\B&C APPLICATIONS-OFFICE USE\MULTIPLE DWELLING.doc Inspection Form Town of Queensbury Fire Marshal <D Periodic Inspection Date: ±04a ime: 742 Bay Road,Queensbury NY 12804 o Re-Inspection 518 761 8206/518 761 8205 o CO Inspection Permit#: Fire Marshals Representative _MJ Palmer Business Name: —L Location: .5441 NN _ GK Stillman Contact: Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.2 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles in E ui ment Rooms FC315.2.3 F.D.Signage- FC 510 No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6 111 &112 Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY Vacant Buildings FC 311 Emergency Disconnect FC 2203.2 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection f Akerpolt-I/0 -1 Rough Plumbing / Insulation Inspection Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: ,-.,c am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: C E NAME: �'C�t�-p L�:Ddq PERMIT #: 1,3 oto / LOCATION: '� ` ,� c 1 INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 �)NC-- ;k-_[ o Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date In ection request received: 64-613 Queensbury Building &Code Enforcement Arrive: G,, am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /3-201 NAME: &tjb �� �� ERMIT #: - LOCATION: 5 v� INSPECT ON: !' TYPE OF STRUCTURE: 41 -J �'q Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head or 15 minutes Insulation / esidential Check/Commercial Check vyvek—or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date In I tion request received: Queensbury Building&Code Enforcement Arrive: �Yv am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: QA 1-1-�/ 13 -Zo/ NAME: (y5z C Ury LcPERMIT#: LOCATION: INSPECT ON: 2.)'113 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'h inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing l Insulation Inspection Report Office No. (518) 761-8256 Date inspecti9n request received: Queensbury Building &Code Enforcement Arrive: /V5 am/.T Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's inivais: �%� ,910l NAME: C; PERMIT #>t: % 4 LOCATION: 3L-ciiec INSPECT ON: Lo-4H3 TYPE OF STRUCTURE: Y N N/Ai Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place r 1 %inch minimum Drain Size 3 Wash129 Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Prop2r Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: 4 rr� am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#. J LOCATION: 3 w & f< I f INSPECT ON: TYPE OF STRUCTURE: PS '� {" ivy Framing Y N N/A COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12°O.C. . Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Pell T `f Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiiding&Codes Forrns-01.13\1300ng&CodesNinspedlon FormsTrarring Firestopping Inspection Report.doc Revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date ins ecti n request received: Queensbury Building &Code Enforcement Arrive: 10 am/o , Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: '�--co'� PERMIT #: LOCATION: INSPECT ON: q/e3 TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates j 74 Plumbing Vent/Vents in Placej� l 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head V/ 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reporkrevised Nov 17 2003, revised February 15,2005, revised January 7,2008