2013-201 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERP-"vHFIC ATE OF OCCUPANCY
Permit Number: P20130201 Date Issued: Friday, December 20, 2013
This is to certify that work requested to be done as shown by Permit Number P20130201
has been completed.
Location: 543 AVIATION Rd
Tax Map Number: 523400-302-005-0001-05 1-000-0000
Owner: AFTAB BHATTI
Applicant: AFTAB BHATTI
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
RM a\q I a 5, �as TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan,Variance, or
j/V t—
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20130201 Application Number: A20130201
Tax Map No: 523400-302-005-0001-05 1-000-0000
Permission is hereby granted to: AFTAB BHATTI
For property located at: 543 AVIATION Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: AFTAB BHATTI Commercial Alteration $2,000.00
547 AVIATION Rd Total value
QUEENSBURY,NY 12804-0000 $2,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2013-201 ECONO LODGE
Comm Alt. bathrooms Rms 9219, #125 á
r
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, May 16,2014
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Thursday,May 16,2013
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
' oppusua�ow�r
.
� ��� ^av
TAX MAP wo�l��__'_____--___ � ' �/� lE 2013 �
. , . .
'
FssmPERMIT � ' |
. ___ _ _�______ '- �-_ ' . .
�
(if applicable)
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING
PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION mSUBJECT TO REVIEW
BEFORE ISSUANCE opAVALID PERMIT FOR CONSTRUCTION.
Appucawnau/Loem OWNER:
xooxEaa: led Aooneoo:
r*DNENOS. e 793 PHONE NOS.
CONTACT PERSON FOR BUILDING mCODES CO
LOCATION oFPROPERTY:
R'
NO
[]YES mo
/FSO,INDICATE APPLICATION NO.AND DATE 0rAPPROVAL:
II PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
LL X
SINGLE FAMILY
(NO.of UNITS
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
OTHER
|rCOMMERCIAL oaINDUSTRIAL-NAME OF BU a|wsSa
ESTIMATED CONSTRUCTION uoaT�� puELTYps:
HEAT TYPE: 'HOW MANY F|*EpL^Ce(S): AND/onvvoOo3T0veG(a):_______
ZONING CATEGORY: ARE THERE WETLANDS DwTHIS SITE?
|oTHIS AHISTORIC SITE?
___
PROPOSED USE opBUILDING onADDITION:
ARE THERE STRUCTURES NOT SHOWN ONPLOT PLAN?
ARE THERE EASEMENTS VNPROPERTY?
^p/e*cecumwmcaoenanaTc,Aw/|/,mucn*,^+ua/Burning Armfioo'mpxin our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
Signe W 2'AW' 4'0
Director of Building&Codes: 781-8258(for questions regarding Building Permits,construction codes
or septic systems)
^
Zoning Administrator,
761-8218(for questions regarding required permits, the permit process,
application requirements orhuschedule unappointment)
r~~—'---^--'—'—'''—'''^-----'- ,---------'-----------'''—'----''-----�
' . ^
� Permisaion is hereby granted to the above This application/proposed action described �
�
Applicant to erect or alter the building herein is found to be in accordance with the �
�
described herein in accordance with said zoning Laws ofthe Town ofQueensbury. |
�
Application:
. . . ^
. . . .
� � � �
~ �DA
~~. ~~.'. . ..'.� ' ^ ZONING APPROVAL .
�� DATE '
QUESTIONS 7 CALL 761-8256 Oft EMAIL
Office Use Only. VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issued: —Yes w
Occupancy Type: Construction Classification:
Assembly Occupancy umu: Special Conditions:
Town ofQueensbury°Community Development Office°742Bay Road,Queensbury NY 12804
io Report
Comm` rcial Final Ins n po
Office No.: (518) 761-8256 Date Inspectioryc�q�r s ceiv
Queensbury Building &Code Enforcement Arrive: a am
742 Bay Road, Queensbury, NY 12804 Inspector's In'
NAME: tLd ( -`" PERMI
LOCATION: DATE:
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Th h Roof 6"/Roof Complete
Exterior Finish/Grade Com to 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Stop Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft
All Doors 36 in.wA ever Handles/Panic Hardware if required
Exits At Grade Or Platform 36 w x 44°(lypanopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18' Above Grade
Floor Bathroom Wateftht/Other Floors Oka
Relief Valve Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Fumace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Sup&for Occu /Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/doors
> 10%> 1000 sq.ft.
%Hour Corridor Doors lit Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dam rs/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Spam Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Si /Shaft Sealed
Handica Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters 34 in. Checkout 36"
Handicapped Ramp/Handrails Continuous112 in.Beyond[Both
sides
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Fk)od Plain certification If
As-built SepticSystern Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
'Building Access AN Sides by 20'1 Driveable Surface 20'wWe
Okay To Issue Temp. or Permanent CIO
Okay To Issue CIC
LABuilding&Codes Forms\Building&Codesllnspection FormslCommeraal Final Inspection Reportdoc Revised January 7,2008
-1
Multiple Dwelling, Hotel, Motel, Apartment
Final Inspection Report
Office No.: (518)761-8256 Date lnspen re reciv d:
Queensbury Building&Code Enforcement Arrive: /'r Depart: am/pm
742 Bay Road,Queensbury, NY 12804 Inspector's I '' s: f I j
NAME: &V&D A" ERMIT#: 1 3'o� l
nnl V
LOCATION: � 3 A Q ta+,p I DATE: I j 3
Y N NA COMMENTS:
Chimney Height/ "B" Vent/ Direct Vent Location
Plumb Vent Thru Roof Minimum 6"
Roof Complete pp
Exterior Finish Complete / Finish Grade 6" In 10' Drop �v\
Interior/Exterior Railings 34 Into 38 in. / 36" Landing,
Decks, Porches
Exterior Handrails, Balconies, Landing 30" Or More
Interior Handrails Balconies/ Landing 30" Or More --
Interior Handrails Stairs 1 or More Risers
Guardrails 42", Ballisters 4" Minimum Spacing
Vestibules For Exit Doors > 3000 sq. ft. _
Doors 36" / Lever Handles � =
Headroom 6' 8" on Stairs
4"
Bathroom / Kitchen Watertight -- ,
Smoke Detectors: Every level, Every bedroom
Outside every bedroom, Interconnected Battery
Backup -�-'
Carbon Monoxide Alarm -lowest sleeping level � �
Bathroom Fans / PlumbingFixtures Complete
Foundation Insulation
Fire Separation, 3/4, 1, 2 hr. -'�
Fire Walls 1, 2, 3 Hour/ Fire Door 3/4, 1 '/z, 2 Hour
Handicapped Accessibility/ Handicapped
Parking/Signage
Gas Log In Sealed or Glass Enclosure
Gas Valve Shut-Off Exposed / Regulator 18" Above
Grade '
ge
Gas Furnace Shut-Off Within 30 ff. or Within Line Site
Oil Furnace Shut-Off at Entrance to Furnace Area
Furnace / Hot Water Heater Operating /Fresh Air Intake
Low Water Shut-Off for Boiler fr'
Relief Valve, Heat Trap /Water ternp 110 Degrees Max. r
Garage Fireproofing Complete, Penetration Sealed
Furnace In Separate Room / Protected In Garage) )
Light Ventilation per Room /Safety Glazing
Attic Access 30" x 20" x 30" H /Crawl Space 18" x 24" /
Final Electrical
Site Plan/Variance Required
Final Survey Plot Plan / Flood Plain Certification, if Reg.
As-built Septic System Layout Required
Building /Apartment Number on Building or Driveway
Build Access All Sides by 20', Driveable Surface 20"Wide
Okay To Issue Tem C/O or Permanent CO (circle one)
Okay To Issue C/C ;
L:\B&C APPLICATIONS-OFFICE USE\MULTIPLE DWELLING.doc
Inspection Form
Town of Queensbury Fire Marshal <D Periodic Inspection Date: ±04a ime:
742 Bay Road,Queensbury NY 12804 o Re-Inspection
518 761 8206/518 761 8205 o CO Inspection Permit#:
Fire Marshals Representative
_MJ Palmer Business Name: —L
Location: .5441 NN _
GK Stillman Contact:
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Sign:Normal FC 1011 &FC1029
Sign:backup FC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.2
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles in E ui ment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6 111 &112
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY
Vacant Buildings FC 311
Emergency Disconnect FC 2203.2 21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506
Operating Permit, if required will be issued after
Completion of Inspection
f Akerpolt-I/0 -1
Rough Plumbing / Insulation Inspection
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: ,-.,c am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: C E
NAME: �'C�t�-p L�:Ddq PERMIT #: 1,3 oto /
LOCATION: '� ` ,� c 1 INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
�)NC-- ;k-_[ o
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date In ection request received: 64-613
Queensbury Building &Code Enforcement Arrive: G,, am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
/3-201
NAME: &tjb �� �� ERMIT #: -
LOCATION: 5 v� INSPECT ON: !'
TYPE OF STRUCTURE: 41
-J �'q
Y N NIA
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
or 15 minutes
Insulation / esidential Check/Commercial Check
vyvek—or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date In I tion request received:
Queensbury Building&Code Enforcement Arrive: �Yv am/pm Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: QA
1-1-�/ 13 -Zo/
NAME: (y5z C Ury LcPERMIT#:
LOCATION: INSPECT ON: 2.)'113
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'h inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing l Insulation Inspection Report
Office No. (518) 761-8256 Date inspecti9n request received:
Queensbury Building &Code Enforcement Arrive: /V5 am/.T Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's inivais: �%�
,910l
NAME: C; PERMIT #>t: % 4
LOCATION: 3L-ciiec INSPECT ON: Lo-4H3
TYPE OF STRUCTURE:
Y N N/Ai
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place r
1 %inch minimum Drain Size 3
Wash129 Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.1 for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Prop2r Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: 4 rr� am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#. J
LOCATION: 3 w & f< I f INSPECT ON:
TYPE OF STRUCTURE: PS '� {" ivy
Framing Y N N/A COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12°O.C. .
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Botts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min. Pell T `f
Garage Fire Separation
House side %inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuiiding&Codes Forrns-01.13\1300ng&CodesNinspedlon FormsTrarring Firestopping Inspection Report.doc Revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date ins ecti n request received:
Queensbury Building &Code Enforcement Arrive: 10 am/o , Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: '�--co'� PERMIT #:
LOCATION: INSPECT ON: q/e3
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing/Nail Plates j
74
Plumbing Vent/Vents in Placej�
l
1 %inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head V/
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent,Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reporkrevised Nov 17 2003, revised February 15,2005, revised January 7,2008