Loading...
2013-453 TOWN OF QUEENSBURY 742 BayRoad,Quccnsbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20130453 Date Issued: Tuesday, November 04, 2014 This is to certify that work requested to be done as shown by Permit Number P20130453 has been completed. Location: 346 CLEVERDALE Rd Tax Map Number: 523400-226-012-0001-070-000-0000 Owner: JAMES & SUSAN MOONEY Applicant: JAMES & SUSAN MOONEY This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property (Dayfi41 owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. 004 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 wvg.43, Community Development- Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20130453 Application Number: A20130453 Tax Map No: 523400-226-012-0001-070-000-0000 Permission is hereby granted to: JAMES & SUSAN MOONEY For property located at: 346 CLEVERDALE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAMES & SUSAN MOONEY Residential Addition $10,000.00 BOX 234 Total Value $10,000.00 CLEVERDALE,NY 12820 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2013-453 Res. Addition 154 sq ft&Res. Alteration 105 sq ft&New DECK 179 sq ft $100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 31, 2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town f Que sbu 'Th d , October 31,2013 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement • Office Use Only Town of Queensbury Building & Codes Received: nre PRINCIPAL STRUCTURE APPLICATION Tax Map ID: ._ , nID Permit No.: � — A permit must be obtained before beginning construction Permit Fee: $ U 0 Please read: *TB resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling *Rec Fee: $ units, including single-family dwellings,duplexes or two-family dwellings, multiple family Site Plan No.: dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.: homes,but not including mobile homes. This is in addition to the permit fee. Date 9' Z3 /3 Applicant deg Oczina Tax Map ID - /2 —/— 70 Address Zoning I,v/L Phone/E-mail L;.T�•3Si/Z. — yj J-0 Property Owner het»i OS Sus4PJ m0 avl'y Contractor/Agent Re-; Address 2 c-/C e k6.74-.D6,-. . Address h�a t,C.,. c 7 D l A S• �n s� SiuS ce � 6G Phone/E-mail T.- Moa,�.e/ a o r2u tivw,oe-- Phone/E-m ', r 3a k CE 56-1 - 5 7 Building Street Address: 3c-t6 C«vsriic..-Z Subdivision Name: i✓/il Lot#: N/ Historic Site: Yes Estimated cost of construction: $ /c- c7 oc? �/— Type of Construction: Check all that apply Please indicate measurements as required below: c 0 0 1st Floor 2nd Floor Other Total Height Z a alakserretstr Single Family 1 Zg t/1/ 'r Two-Family Multi-Family(#of units_J Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garages(#_) Other Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 If commercial or industrial indicate name of business lA l' A,- Proposed use of building or addition rl •—•-1 Source of heat(circle one) Gas Oil /-"Propane Solar Other Fireplace-complete a separate application for"Fuel Burning Appliances&Chimneys" Yes Are there structures not shown on plot plan? 0 Are their easements on the property? Site Information a. Dimensions or acreage of lot 2e2, 6 lc b. Is this a corner lot? c. Will the grade be changed as a result of construction: Yes '"10 d. Public water or Private well e. Sewer or Private Septic System P2 t T 6- S.:e_ 'sr. Sof Value of all work to be performed (labor and materials) $ 1 O) v U�(1- ) Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. I certify that the application,plans, and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances,and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read ardagree to the ab, e. Sig ned (4,-4)(-16) v Date: t 22 rte' "� FOR OFIFICE USE ONLY: Operating Permit Issued: _Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit Special Conditions: Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 fry 1-3 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/prg De art -1 am/pm Date Inspection request received: Inspector's Initials: ( J{ NAME: nn L 11 PERMIT#: 13- J 5 3 LOCATION: q Z j Q relic 1Q A d DATE: `— 1) TYPE OF STRUCTURE: S 4,4,4 Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete tl//: Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more ✓ Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing I Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim I doors I main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in st-'.4s safety blzzing Interior Smoke Detectors/ (arbon Mono i•- Detectors Every level: Every :-• •• . Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Y Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss, draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/,hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% ✓ Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codesllnspection Forms1Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 Foundation Inspection Report /(370(1-\ Office No.(S 18)761-8256 Date Inspection request received: (-7Z.-7 _&7% Queensbury Building&Code Enforcement Arrive: am/pm Depart: �, pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials• /"j NAME: POOkevtgai PERMIT#: a d / 3' 7/ 5-3 LOCATION: 3 4f( ' � a,/IL-INSPECT ON: .L '_ - i/j c,L TYPE OF STRUCTURE: ; -i Comment �-- &;/ N N/A Ftings N.-726k_ Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Walipour Reinforcement in Place Footing Dowels or Keyway in place • Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Nvnaky Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: f/,� 1 am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: INt5f1 PERMIT#: // 3 513 LOCATION: 3 La L ,�` J ±La INSPECT ON: c57- TYPE TYPE OF STRUCTURE: 2 4—od Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain /Vent Air / Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I. for for 15 minutes Insulation / Residential Check / Commercial Check / Window Sealing V Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: — ° (' ‘A-A-A'7-)- -› )2>--- ,.Jt --v\AA-)---L---7 Rough Plumbing_Insulation Inspection_02 05 13 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date In^spection equest received: Queensbury Building & Code Enforcement Arrive: `•- • am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ' NAME: ,M DeD PERMIT#: ) 3 1 53 LOCATION: 3 `j INSPECT ON: ''- 87--j7 TYPE OF STRUCTURE: Y N N/A Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent /Vents in Place ,/ 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test \ Drain /Vent Air / Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing Insulation Inspection_02 05 13 Town of Queensbury Building & Code Enforcement 3 ppm Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received:� POName: t ► 1 . Inspected on: Location: '`{.(o e_SLD Rca Arrive: a.m./p.m. Permit No.: / 3 - <1 53 Inspector's Initials: < 2� TYPE OF STRUCTURE: N N/A COMMENTS: laremipg Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts!Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in,or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w)16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour .. tn� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report Town of Queensbury Building & Code Enforcement i — Y Office No. (518) 761-8256 Framing I Firestopping Inspection Report Inspection request received: Name: Inspected on: Location: 3 1p ctaaLz_ Arrive: '\ I a.m.I p.m. Permit No.: ( 3 - `{(5'3 Inspector's Initials: 1i.06. TYPE OF STRUCTURE: ed_ (A nom e Co 56:2-3 4y/N NIA COMMENTS: Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall /1 Fire separation 1,2,3 hour Fire wall 2,3,4 hour !. ` Firestopping 0! Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report /2- /� - ) o.� Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: L. am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials. �, NAME: Plit,ZEL( PERMIT#: 2O C3 -4,53 LOCATION: ZACe diC,120M, e[ INSPECT ON: TYPE OF STRUCTURE: % icy) Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump ` Footing Drain Stone: v 12 inch width _ / 6 inches above footing y 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /2 ' 9 . Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: / � : pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: e NAME: PERMIT#:Zc---) - LOCATION: ---` jj —\}' s-12-0 INSPECT ON: 4 / I i 4— TYPE OF STRUCTURE: 0 j - 5 ,4-r Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. s Foundation/Walipour ` Reinforcement in Place Footing Dowels or Keyway in placeV// • , 5, . Foundation Dampproofing A 7 - Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: l i am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: & G NAME: PERMIT#: °` L . —A LOCATION: � 4 ' ---C24)' INSPECT ON: U! TYPE OF STRUCTURE: (2 '—�, +- Comments Y N N/A Footings y Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wailpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fors\Building&Codes\Inspection Fors\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM Nn i bfi IV yo 1 I m � ---------= Ji 0 3 N " sQN a go Is Li Li -7;,OZ -,t s- -a'b 0 aZp W Q Q //PnJ ✓i ri/Pf JA )�a/JuJ N'�l�J \ � \ �cy� T ' `ti �• � .coo �\ � v � 2 ----------------- > ♦'------ 3 N o'• u" e v --- w � ,� .o• d � .i mi o � � 0 Lij I o 0 1 i � z � a w r. iii o a uoW ro 1 o Q e Iwo— Is o N h�C � uQ o r