Loading...
2013-508 0" TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Q rY, Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20130508 Date Issued: Tuesday, January 21, 2014 This is to certify that work requested to be done as shown by Permit Number P20130508 has been completed. Location: 756 GLEN St Tax Map Number: 523400-302-006-0001-051-002-0000 Owner: QUEENSBURY PLAZA I, LLC Applicant: VITAMIN WORLD This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property 41 owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. 1 TOWN OF QUEENSBURY e. 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130508 Application Number: A20130508 Tax Map No: 523400-302-006-0001-051-002-0000 Permission is hereby granted to: VITAMIN WORLD For property located at: 756 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: QUEENSBURY PLAZA I,LLC Commercial Alteration $75,000.00 400 ANDREWS St Suite 500 Total Value ROCHESTER NY 14604-0000 $75,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2013- 508 VITAMIN WORLD Comm. Alter. 1,177 sq ft $235.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,November 01,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town u sbury• if Fri s : , ovember 01,2013 SIGNED BY _r for the Town of Queensbury. Director of Building&Co.e Enforcement Office Use Only Town of Queensbury Building & Codes Received: �� Z . Q1. PRINCIPAL STRUCTURE APPLICATION Tax Map ID. Permit No.: /3-5o g A permit must be obtained before beginning construction Permit*Rec F Fee;.$ O3 5$ e ptPlease read: *TB resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling �j�f� i `1D units, including single-family dwellings, duplexes or two-family dwellings, multiple family Site Plan Nb.. dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.:_ _ homes,but not including mobile homes. This is in addition to the permit fee. Date to( cg-SI t3 Applicant VI 4aM 1 n 1,0519 c4 `- 0CP(7 Tax Map ID Address A1,3(0 PUACI LUC& Zoning ---cevr,Or r a--i6( _3.:9.6 B Y Phone 1 E-mail 9011.441 L. (� i(Y 0 k om Yn cru eco cor- Property Owner GfJJLY\ t"C'C Y\ act Agent 1'"�.V Address 4 O Q.mC &Qi -. -SUU Address v t^\ i y t, di Phone/E-mail gS . 4410• 4 g`(a(0 L . Phone/E-mail Contact Person for Building &Code Compliance: rc,4IzO k�� eh , Atli- Day Phone:904/ 417/63/y Building Street Address: 1 rS-�\. �1rY� Subdivision Name: -1 Lot#: 10.8 Historic Site: • Yes \ No Estimated cost of construction: $ 7 S , 000 ‘.., t/`----) Type of Construction: Check all that apply Please indicate measurements as required below: c = 0 4 :a d 1st Floor 2nd Floor Other Total Height E: z ¢ a Single Family Two-Family Multi-Family(#of units ) Townhouse Business Office bM Retail-Mercantile / 1m 1 f l'l .Ip 0d-1-- Factory-Industrial Attached Garages(# ) Other Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 If commercial or industrial indicate name of business \ l t jr-CLIY-1 4 1 , t A Proposed use of building or addition Source of heat(circle one) Gas Oil Propane Solar Other — "n Fireplace-complete a separate application for"Fuel Burning Appliances&Chimneys" _Yes _No Are there structures not shown on plot plan? ,Y Are their easements on the property? ° Site Information a. Dimensions or acreage of lot b. Is this a corner lot? n c. Will the grade be changed as a result of construction: _Yes V No d. Public water or Private well ,, ,r t S tet''I ,3 3 e. Sewer or Private Septic System SCJ . _ is Value of all work to be performed(labor and materials) $ rT C l 00 Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Print Name: iJ 'VO)-1 / 5 Signature: 1 / Date: / � FOR OFFICE USE ONLY: Operating Permit Issued: _Yes _No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Commercial Final Inspection Report 1 f >( pp / Li - Office No.: (518) 761-8256 Date Inspection requ`4 -ec-iv•d: (/ 1V/ l Queensbury Building & Code Enforcement Arrive: 7 .�>am/. Depart: 7.: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:0M NAME: �� , � (-v c' ( l� PERMIT : S LOCATION: 7 (c GLS ST eE 1 DATE: COMMENTS: Y N NA Chimney/ "B"Vent/ Direct Vent Location Plumbing Vent Through Roof 6"/ Roof Complete Exterior Finish /Grade Complete 6"in 10'or Equivalent Interior/ Exterior Guardrails 42 inch Platform / Decks Interior/ Exterior Balusters 4 inch Spacing Platform / Decks Stair Handrail 34 inch— 38 inch / Step Risers 7"/Treads 11" Vestibules For Exit doors > 3000 sq. ft. All Doors 36 inch w/Lever Handles/ Panic Hardware, if required Exits At Grade Or Platform 36"(w) x 44"(I)/ Canopy or Equiv. NN/// Gas Valve Shut-off Exposed &Regulator (18")Above Grade Floor Bathroom Watertight/ Other Floors Okay Relief Valve, Heat Trap / Water Temperature 110 Degrees Maximum Boiler/ Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/ Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 ' doors > 10% > 1000 sq. ft. 3/4 Hour Corridor Doors &Closers Firewalls/ Fire Separation, 2 Hour, 3 Hour Complete/ Fire Dampers / Fire Doors Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/ Shaft Sealed Handicapped Bathroom Grab Bars/ Sinks/Toilets/ Mirrors Handicapped Bath/ Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 inch, Checkout 36 inch Handicapped Ramp/ Handrails Continuous/12 inch Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical / Flex Gas Piping Bonded Site Plan/ Variance required Final Survey, New Structure/ Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" tN( Water Fountain or Cooler Building Access All Sides by 20'/ Drivable Surface 20'wide Special Inspections/ Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O . Okay To Issue C/C Commercial Final Inspection Report_revised 11-27-2012 � 11i1 j Inspection Form �o Town of Queensbury Fire Marshal O 'Periodic Inspection Date: ���Time: 2 742 Bay Road,Queensbury NY 12804 Rection /-6-5- 5 518 761 8206/518 761 8205 O Inspection Permit#: Fire Marshals Representative � ) �� 1 , ��� f MJ P Imer Business Name: 6Y�^� �/� LV / Location: 7✓ tJ r2-6- r____ s 1t 13 ' K Stillman Contact: Type of Inspection N/A Yes. No EXITS: Exit Access FC 1014&FC1029 . NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 e Sign:backup FC 1011.5.3&FC1029.7.5 r AISLES: Main Aisle Width FC 1024/1025&FC1029.11 ,,,• 4. Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.2 .,--.--"d TRUSS ID SIGNAGE FC 505.3 ...-/-' EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 _ — Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 ---<� Combustibles in Equipment Rooms FC315.2.3 1 F.D.Signaqe- FC 510 No Smoking Signs FC 310.3 ../'-.� 6_10 Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) �/ Fuel Pump Warning Signs FC2205.6 ..- -- Fuel Station Emer Procedures FC2204.3.5 _ Exterior Storage FC 315.3 .� REINSPECTION DUE APPROXIMATELY Vacant Buildings FC 311 Emergency Disconnect FC 2203.2 ../ 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: _ OK NC HVAC Shutdown Sprinkler System Annual .x Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual _ Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection