Loading...
2013-535 ..001% TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20130535 Date Issued: Monday, December 02, 2013 This is to certify that work requested to be done as shown by Permit Number P20130535 has been completed. Tax Map Number: 523400-309-009-0002-001-000-0000 Location: 200 LUZERNE Rd Owner: HOMESTEAD VILLAGE L P Applicant: HOMESTEAD VILLAGE L P This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the /. property owner of the responsibility for compliance with Site Plan, 4. Variance, or other issues and conditions as a result of approvals by the Director of Building& Code Enforcement Planning Board or Zoning Board of Appeals. 0164 TOWN OF QUEENSBURY '.4 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130535 Application Number: A20130535 Tax Map No: 523400-309-009-0002-001-000-0000 Permission is hereby granted to: HOMESTEAD VILLAGE L P For property located at: 200 LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HOMESTEAD VILLAGE L P Septic Alteration Residential 4294 ROUTE 5 Total Value CALEDONIA,NY 14423 Contractor or Builder's Name /Address Electrical Inspection Agency SANITARY SEWER GEORGE DRELLOS 792-7257 PO BOX 224 GLENS FALLS NY Plans&Specifications 2013- 535 144 Elmhurst Res. Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,November 20,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o uee bury; `'`'e e s I1 November 20,2013 SIGNED BY � for the Town of Queensbury. Director of Building&Code Enforcement �s< Community Development Office Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 Office Use Only? ` TAX MAP NO.3 ��- �—I PERMIT NO.13-535 PERMIT FEE `l D APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: /1O/v1 C' S' c'Af"'" ////�r INSTALLER:Sdt� � �//T � �� J✓[�' —Cer �r ADDRESS: Gd f' /7 y G /,<'iiSt ADDRESS: PO . •aO X 2 z J 6'/ #-s ) z,i% PHONE NOS. PHONE NOS.57 -7 ? 7z J`7 LOCATION OF INSTALLATION: RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION = BEDROOMS (Gallons per bedroom) TOTAL DAILY FLOW GARBAGE GRINDER 1980 or older X 150 = INSTALLED? r'(-1 1981 -1991 X 130 = SPA OR HOT TUB „„/'v 1992-present X .tp /G'7l = INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING V"- STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND oC LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? /' — ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH?M" ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS _PER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: GALLON (MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: e-e- Pis ABSORPTION FIELD(WITH NO.2 STONE) Total length 512 ft. Each trench 3"O x o SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? o HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sani ew • os mance. //_/Y✓/� codes(a�queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION Signature of Person Responsible Date www.queensbury.net Septic Inspection Report Office No. (518) 761-8256 Date Ins•- ion r-• es ed. Queensbury Building &Code Enforcement Arrive: • = _ •• I-= rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: . \ NAME: I- )el �TE11O \rk' LL GE P •MIT NO.: `�2)— 3 LOCATION: s' \ k- E _ % 1W, J SPECT ON: (2-7 — RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance _ ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x _ Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: _Y N End Cap _Y_ N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade _Y N [provide extension collar if Yes] _Y_ N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. �anf.ornasr Plot Plan _ N Engineer Report eid As-Built Y N ETtt Maintenance Contract _Y_ N provided Location of System on Property: Front r Left Side Right Side Middle Front Middle Rear S stem Use S us: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Fomis\Inspection Forms\Septic Inspection Report03 29 10.doc ENVIRONMENTAL DESIGN PARTNERSHIP, LLP December 2, 2013 Queensbury Building & Code Enforcement 742 Bay Road Queensbury,NY 12804 Via email johno@queensbury.net Attn: John O'Brien Re: Homestead Village Mobile Home Park Lot 144 Elmhurst Dear John: On November 26, 2013 our office inspected the above referenced Homestead Village Mobile Home Park lot. The purpose of this visit was to observe the installation of the new septic system designed by EDP dated November 8, 2013. Based on my review of the plans and observation of the installation it is my opinion that the system was installed substantially in compliance with the intent of the design plans. Please contact me should you have any questions regarding this system. Sincerely, C:7917 James E. Mitchell, P.L. 900 Route 146, Clifton Park, New York 12065 phone(518) 371-7621 -fax (518) 371-9540 Town of Queensbury Building & Code Enforcement LJa // -'/1 . 30 Office No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: - ines-kgead Inspected on: — .-I _ Location: / /'./ P.)rn by I-* Arrive: a.m. .17 Permit No.: / 3- 5 3 5 Inspector's Initials: mments and/or dia•ram 9 m Soil Type:4111111!--.. .ay Type of Water: Munici.. - ater Waterline separation distance I 0 ft. .4— Well ~Well separation distance ft. Other wells: ft. Well Casing Length 50'+/- Y N N/A [150'to well required if NO] Absorption Field: Total length 15O ft. Length of each trench 3a ft. Depth of trenches _ 7- - 3 ft. Size of Stone 4- Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank t_A,' hCG yt-') Tank to Distribution Box Lio. ,LAV---3 Distribution Box to Field/Pit 1--i '' bic)e--- C_TU ti" 13\w.--27.;-7&2. - Opening Sealed: i/Y_N End Cap ✓y N Inlet/Outlet Pipes&Baffles >/Y/ N Manholes 12"or less below grade YY .NN [provide extension collar if Yes] Y %Al Location/Separations Foundation to tank ',j-- ft. Foundation to absorption ij ft. . Separation of Pits / ft. Conforms as per Plot Plan v1' N/ \ E-C Gam'�k ._ 2,%1 ' �"`-` Engineer Report and As-Built Y VN ETU Maintenance Contract provided Y—N Location of System on Property: Front Rear Left Side fight Side Middle Front Middle Rear System Use Status: pproved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Septic Inspection Report INSPECTION REQUIREMENTS: ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING. NO TE: 7) BASEMAP INFORMATION OBTAINED FROM PUBLICLY AVAILABLE RESOURCES AND DOES NOT REPRESENT AN ACTUAL FIELD INSTRUMENT SURVEY. LEGEND E.O.P. DENOTES EDGE OF PAVEMENT MIN. DENOTES MINIMUM PVC DENOTES PLASTIC PIPE SAN DENOTES SCHEDULE 0. P. DENOTES UTILITY POLE ,G S, DENOTES WATER SHUTOFF LOT 140 LOT 141 PROPOSED 1,000 GALLON SEPTIC TANK (SEE DETAIL — SHEET 2) rr F_ z�� I I I I I � C I JI) I PROPOSED 4" PVC SCH 40 AT 2% MIN. PROPOSED DISTRIBUTION BOX #2 (SEE DETAIL — SHEET 2) EXISTING r �1 r — / EXIISTNc SEPTIC I SYSTEM I � �— T' EXISTING MOBILE HOME LOT 145 LOT 144 PARKING AREA PARKING AREA , Ws, E.O.P. ELMHURST DRIVE ° w m�� Ups °_v) EXISTING SANITARY STRUCTURES a� INCLUDING SEPTIC TANK AND SEEPAGE v DEVICES ARE TO BE CRUSHED IN PLACE AND FILLED WITH NATIVE MATERIAL. PROPOSED ABSORPTION FIELD 3 LINES AT 50 FT. EACH (SEE DETAIL — SHEET 2) NOTE: I , LOT 143 , PARKING AREA E.O.P. AND 4" PVC SDR —35 L) AT 1% MIN. a G W Y o EXISTING TREES TO BORING AND PERCOLATION TEST: ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING PERCOLATION RATE APPROXIMATELY ONE MINUTE NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. SEPTIC DESIGN: APPLICATION RATE = 1.2 GAL./SF/DAY LOT 144 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS USE EXISTING 1000 GALLON SEPTIC TANK USE 3 LINES AT 50 FT. EACH (SPACED 6 FT. ON—CENTER) CONSTRUCTION NOTES: 1) CONSTRUCTION OF ABSORPTION. FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR THE SOIL MOISTURE CONTENT.. IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE MOISTURE CONTENT IS TOO HIGH .FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE EX0,1VATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (LE., SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX ,MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE DESIGNATED ABSORPTION SYSTEM :AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE MISALIGNMENT/BREAKAGE 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH. SHALL BE AS SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO ASSURE THAT EACH IS PRACTICALLY LEVEL TRENCH BOTTOMS AND SIDEWALLS SHOULD BE IMMEDIATELY RAKED AFTER. FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY: INSTALLED AT. A SLOPE OF %6 TO Y32 INCH PER ' FOO I. ` PRESSURE OR. DOSED DISTR13UTOR PIPE SHALL BE INSTALLED .LEVEL. GRADES SHALL BE DETERMINED BY AN ENGINEER'S LEVEL, -TRANSIT OR CARPENTERS LEVEL..- AN EASY METHOD OF MEASURING , -:THE %s INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A %4 INCH BLOCK TO ONE ULEND ED TO^OF A STRAIGHT FOUR FOOT BOARD BY PLACING THE BLOCKED END WITH THE BLOCK - FACING DOWN ON THE DOWNSTREAM A /32 INCH PER FOOT SLOPE. OF THE DISTRIBUTOR OPE. METHOD CH BL A CA ILARLY U LEVEL CAN BE ' ' BLOCK SIMILARLY USED WOULD ED TO ESTABLISH THE GRADE OF AS DISTRIBUTOR EFITH OFT PI LEAST TWO TERINCBOARDS. AGGREGATE AE30VE THE T GA E SHALL THE 'BE INSTALLED IN THE TRENCHES TO DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL DISTRIBUTOR PIPES. ADDITIONAL AGGREGATE MAY BE REQUIRED TO BRING THE TOP. OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES OF FINAL GRADE: 6) AFTER THE UPPER 'AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE UNTREATED BUILDING PAGER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES _CANNOT BE IMMEDIATELY BACKFILLED, THE TRENCHES SHOULD BE TEMPORARILY COVERED WITH AN IMPERVIOUS MATERIAL, SUCH AS TREATED BUILDING PAPER. TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE. 7) THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THEIORIGINAL GROUND LEVEL OE, NOT .COMPACTED) TO ALLOW FOR,. SETTLING.. FOLLOWING. SETTLEMENT THE ENTIRE AREA SHOULD BE GRADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT SHALL NOT ENTER :THE ABSORPTION FACILITY.: AREA OR THE PROPOSED EXPANSION AREA AFTER THE -: SU35URFACE SEWAGE: TREATMENT SYSTEM HAS BEEN CONSTRUCTED. - h 8) A -MINIMUM HORIZONTAL SEPARATION OF10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND WATERLINE W l s ANY WHERE L NE 'MUST CROSS THE .WATER SERVICE LINE SHALL BE AT LEAST 12 INCHES ABOVE THE HOUSE SEWER IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE VERTICAL SEPARATION= MUST BE AT LEAST 18 INCHES R; x 9) ROOF, FOOTING, GARAGE, CELLAR AND SURFACE ATER DRAINAGE MUST BE EXCLUDED FROM THE t`�" .< "�f C1 SY5 rFM. -WATER SOFTENER, WATER RECHARGE A D BACKWASH WASTES NORMALLY ARE NOT TO. BE DISCHARGED TO THE SYSTEM UNLESS A S AT S SURFACE DISCHARGE TO AN ARE 250 FEET FROM WELLS OR WATER COURSES IS UN A L L a z^ SEPTIC PLOT PLA114 OF LL j #ii!�gl j I HAVE SEEN HOUSESRWELLS T REcSAOBSEVU FENUGES, ETC z NALLy 0 Z Q h _ SHO r -HIS DOCUMENT. I HAVE Pt: r l'•£va1i — ric*""10ESETFOp' -V¢ % iH15DIAGRAM� o E CONTRACTOR MUST CONFIRM LOCATION OF EXISTING WATER SERVICES PRIOR TO COMMENCEMENT OF CONSTRUCTION AND MAINTAIN A MINIMUM 10 FT. SEPARATION BETWEEN THE EXISTING WATER SERVICE AND PROPOSED SANITARY SEWER LATERALS MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. THE LOCATION OF THE WATER SERVICE MUST BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION TO CONFIRM PROPER SEPARATION DISTANCE FROM TILE FIELD (MINIMUM 10 FEET) SIGNATURE. - Ln SHEET 1 OF 2 0 SEPTIC DESIGN PREPARED FOR O V LOT 144 ELMHURST DRIVE o HOMESTEAD VILLA GE o 0 TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK a SCALE: 1 " — -20' NOVEMBER 8, 2013 ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P.E. 53, 337 F_ z�� I I I I I o I JI) I I I I I I LOT 145 LOT 144 PARKING AREA PARKING AREA , Ws, E.O.P. ELMHURST DRIVE ° w m�� Ups °_v) EXISTING SANITARY STRUCTURES a� INCLUDING SEPTIC TANK AND SEEPAGE v DEVICES ARE TO BE CRUSHED IN PLACE AND FILLED WITH NATIVE MATERIAL. PROPOSED ABSORPTION FIELD 3 LINES AT 50 FT. EACH (SEE DETAIL — SHEET 2) NOTE: I , LOT 143 , PARKING AREA E.O.P. AND 4" PVC SDR —35 L) AT 1% MIN. a G W Y o EXISTING TREES TO BORING AND PERCOLATION TEST: ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING PERCOLATION RATE APPROXIMATELY ONE MINUTE NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. SEPTIC DESIGN: APPLICATION RATE = 1.2 GAL./SF/DAY LOT 144 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS USE EXISTING 1000 GALLON SEPTIC TANK USE 3 LINES AT 50 FT. EACH (SPACED 6 FT. ON—CENTER) CONSTRUCTION NOTES: 1) CONSTRUCTION OF ABSORPTION. FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR THE SOIL MOISTURE CONTENT.. IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE MOISTURE CONTENT IS TOO HIGH .FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE EX0,1VATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (LE., SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX ,MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE DESIGNATED ABSORPTION SYSTEM :AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE MISALIGNMENT/BREAKAGE 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH. SHALL BE AS SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO ASSURE THAT EACH IS PRACTICALLY LEVEL TRENCH BOTTOMS AND SIDEWALLS SHOULD BE IMMEDIATELY RAKED AFTER. FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY: INSTALLED AT. A SLOPE OF %6 TO Y32 INCH PER ' FOO I. ` PRESSURE OR. DOSED DISTR13UTOR PIPE SHALL BE INSTALLED .LEVEL. GRADES SHALL BE DETERMINED BY AN ENGINEER'S LEVEL, -TRANSIT OR CARPENTERS LEVEL..- AN EASY METHOD OF MEASURING , -:THE %s INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A %4 INCH BLOCK TO ONE ULEND ED TO^OF A STRAIGHT FOUR FOOT BOARD BY PLACING THE BLOCKED END WITH THE BLOCK - FACING DOWN ON THE DOWNSTREAM A /32 INCH PER FOOT SLOPE. OF THE DISTRIBUTOR OPE. METHOD CH BL A CA ILARLY U LEVEL CAN BE ' ' BLOCK SIMILARLY USED WOULD ED TO ESTABLISH THE GRADE OF AS DISTRIBUTOR EFITH OFT PI LEAST TWO TERINCBOARDS. AGGREGATE AE30VE THE T GA E SHALL THE 'BE INSTALLED IN THE TRENCHES TO DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL DISTRIBUTOR PIPES. ADDITIONAL AGGREGATE MAY BE REQUIRED TO BRING THE TOP. OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES OF FINAL GRADE: 6) AFTER THE UPPER 'AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE UNTREATED BUILDING PAGER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES _CANNOT BE IMMEDIATELY BACKFILLED, THE TRENCHES SHOULD BE TEMPORARILY COVERED WITH AN IMPERVIOUS MATERIAL, SUCH AS TREATED BUILDING PAPER. TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE. 7) THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THEIORIGINAL GROUND LEVEL OE, NOT .COMPACTED) TO ALLOW FOR,. SETTLING.. FOLLOWING. SETTLEMENT THE ENTIRE AREA SHOULD BE GRADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT SHALL NOT ENTER :THE ABSORPTION FACILITY.: AREA OR THE PROPOSED EXPANSION AREA AFTER THE -: SU35URFACE SEWAGE: TREATMENT SYSTEM HAS BEEN CONSTRUCTED. - h 8) A -MINIMUM HORIZONTAL SEPARATION OF10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND WATERLINE W l s ANY WHERE L NE 'MUST CROSS THE .WATER SERVICE LINE SHALL BE AT LEAST 12 INCHES ABOVE THE HOUSE SEWER IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE VERTICAL SEPARATION= MUST BE AT LEAST 18 INCHES R; x 9) ROOF, FOOTING, GARAGE, CELLAR AND SURFACE ATER DRAINAGE MUST BE EXCLUDED FROM THE t`�" .< "�f C1 SY5 rFM. -WATER SOFTENER, WATER RECHARGE A D BACKWASH WASTES NORMALLY ARE NOT TO. BE DISCHARGED TO THE SYSTEM UNLESS A S AT S SURFACE DISCHARGE TO AN ARE 250 FEET FROM WELLS OR WATER COURSES IS UN A L L a z^ SEPTIC PLOT PLA114 OF LL j #ii!�gl j I HAVE SEEN HOUSESRWELLS T REcSAOBSEVU FENUGES, ETC z NALLy 0 Z Q h _ SHO r -HIS DOCUMENT. I HAVE Pt: r l'•£va1i — ric*""10ESETFOp' -V¢ % iH15DIAGRAM� o E CONTRACTOR MUST CONFIRM LOCATION OF EXISTING WATER SERVICES PRIOR TO COMMENCEMENT OF CONSTRUCTION AND MAINTAIN A MINIMUM 10 FT. SEPARATION BETWEEN THE EXISTING WATER SERVICE AND PROPOSED SANITARY SEWER LATERALS MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. THE LOCATION OF THE WATER SERVICE MUST BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION TO CONFIRM PROPER SEPARATION DISTANCE FROM TILE FIELD (MINIMUM 10 FEET) SIGNATURE. - Ln SHEET 1 OF 2 0 SEPTIC DESIGN PREPARED FOR O V LOT 144 ELMHURST DRIVE o HOMESTEAD VILLA GE o 0 TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK a SCALE: 1 " — -20' NOVEMBER 8, 2013 ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P.E. 53, 337 FINISH GRADE III=IIII IIII as ASPHALTIC _ SEAL INLET TF4" OR o 8 3 MIN._ BLDG. SEWER �=z A SA NITARY OJ TEE /f z � 4" MIN. -1 ALL JOINTS BELOb'V-' FD LL S U LIQUID LEVEL TO BE - BI TUMINOUS - WATERTIGHT AND INTERIOR o W LEAKAGE TESTED COAT Q � PRIOR TO BACKFILLING SOL 300M c7 BAFFLE WITH OR EQUAL 4"X18" MIN. AY NOT BE ASPHALTIC SEAL INLET —1 THE SL OFF OF THE INLET PIPE BETWEEN THE RESIDENTIAL UNIT AND THE SEPTIC TANK TO BE Y," PER FT T HEAVY DUTY MANHOLE FRAME AND COVER BY CAMPBELL OR EQUAL NSIN EGRADO —IIII- (MH RINGS) 2 I.D. AS PER FORT MILLER OR EQUAL (AS REQUIRED) OUTLET 5'-6" 5'-9" C-8" IIII TO REPRESENT STABLE SLOPES WATER TIGHT JOINT (TYP.) PARGE W/NON-SHRINK CRO T INSIDE & OUT SANITARY TEE TRACER WIRE #8 THEN STRANDED „0„ I W ,Gwirceu � 6" TO 12" LAYER PEA GRAVEL OR CRUSHED STONE SECTION VIEW BEDDING LAYER NOTE: 24" I.D. TAPERED INLET INVERT IS 3" ABOVE PLUG (TYP.) (2" MIN.) THE SLOPE OF THE OUTLET PIPE 1 1 BETWEEN THE SEPTIC TANK AND THE DISTRIBUTION BOX TO BE %4" PER FT In H CUTLET �I \_ BAFFLE NOTE: 1 1 MAY NOT BE BAFFLE NOT REQUIRED FOR j REQUIRED TANKS LESS THAN 10 FT. LENGTH .,D,. I C., PLAN VIEW OUTSIDE LIQUID DEPTH "A" TANK DIMENSIONS "B"X"C" "0" "I" HEIGHT ANN SIZE MIN. BE PLACED UNDER PAVEMENT GRADE NOTE: CONTRACTORS MUST COMPLY WITH ALL 1 1 000 GAL. 5'-0" 4'-3" x 8'-2'• 5'-6" 5'-9" C-8" IIII WHERE TRENCH SHIELD IS USED TLlJTYTTLLF WITH THE APPROVAL OF THE ENGINEER, SHEETED TRENCH PAYMENT LIMITS WILL APPLY. ALL BACKHLL MATERIAL TO BE PLACED IN 8" LIFTS AND BE COMPACTED TO 95% STANDARD PROCTOR (ASTM D698). DEBRIS, FROZEN MATERIAL, LARGE-- CLODS ARGECLODS OR STONES, ORGANIC MATTER, OR OTHER UNSUITABLE MATERIALS SHALL NOT BE USED AS BACKFILL. SELECTED GRANULAR FILL PLACED IN 6" LIFTS AND MECHANICALLY TAMPED OR, OO.B.E. SEE NOTES 1&2, CRUSHED STONE OR SELECT GRANULAR MATERIAL AS ORDERED BY ENGINEER (MECHANICALLY TAMPED) OR A.O.B.E.. SEE NOTE 2, FOR UNSTABLE TRENCH BOTTOM USE ADDITIONAL DEPTH OF STONE AS NECESSARY TO PROVIDE A FIRM FOUNDATION. 4VEMENT OR RIGINAL GROUND SELECTED GRANULAR FILL TO 1111 i1 u11 ' A.0 B.E. =AS ORDERED BY ENGINEER BE PLACED UNDER PAVEMENT GRADE NOTE: CONTRACTORS MUST COMPLY WITH ALL 1 1 LOCAL, STATE, IS FEDERAL SAFETY REGULATIONS. TRENCH SLOPES ARE GIVEN FOR (OSHA & N.Y-S. D.O.T.) MAX. PAYMENT LIMITS ONLY FOR 3 F 3 PEN CUT AND ARE NOT INTENDED IIII TO REPRESENT STABLE SLOPES NOT INTENDED TO REPRESENT _ UNDER FIELD CONDITIONS. A SAFE SLOPE T -I - 6" `PoIDE GREEN PLASTIC LOCATOR TAPE, yITT MARKED "CAUTION SEWER BELOW" I- TRACER WIRE #8 THEN STRANDED a COPPER OR STAINLESS STEEL EARTH U r _ r °*+ 2" THICK RIGID POLYSTYRENE INSULATION '- + I(LOCATIONS WITH LESS THAN 4' COVER). -= EXTEND TO MIN 4' BELOW GRADE. NOTES: 1) NATIVE EXCAVATED GRANULAR MATERIAL MAY BE USED IF APPROVED BY THE ENGINEER. TRENCH NOT TO SCALE MIN. FOR PIPE 12 DIA. AND SMAI LER ON. FOR PIPE 14" DIA. AND LARGER WHERE A NATER TABLE CONDITION EXISTS STONE BEDDING SHALL BE WRAPPED IN A NON—WOVEN GEO—TEXTILE ENVELOPE (FABRIC EQUIVALENT TO AMOCO 4545) - 2) CRUSHED STONE NOT TO EXCEED #2 IN SIZE, GRANULAR FILL IS MEET THE FOLLOWING REQUIREMENTS - 0 % IN EXCESS OF 3" 25 %-759 PASSING #4 SIEVE O %-15% PASSING #zoo SIEVE DETAIL O U -IIII II. -11, _ O� OO O�J 00 0 as a0 z" Mw. a FLOWPROVIDE CAPS 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 oQ0 0 0 ON LINE ENDS � pp O �� 67Lo � PrP 0 00 SLOPE PIPE &"TA" PER FT. SPACING OF ABSORPTION TRENCH o' O.C. TRENCH BOTTOM TO BE NEAR LEVEL AND RAKED TRENCH PROFILE ABSORPTION TRENCH DETAIL -_n 1 NOT TO SCALE Z n GRADE TOPSOIL FOR SETTLING NOTE: al FIRE JOINTS TO IBE SEALED WITH F III IIII IIII 12" MINREMOVABLE COVER 2. INVERT ELEVATIONS OF ALL _I i I I I I I I - OUTLET PIPES- MUST BE EQUAL. TERAVEX NO. 2 NONWO`JEN - 3. THE SLOPE OFOUTLET PIPES ti p BETWEEN THE: DISTRIBUTION BOX : I I I- M a w EARTH U INVERT _ INLET2'"MIN EL EV. 0111, EARTH IIII _ 2 CONSTRUCTION FABRICOR UNTREATED BUILDING PAPER BACKFILL W I BACKFILL rc I OR N I I -I I I -III 1 rc Y E ' I-111.1= I S I -I I I1= TOP OF AGGREGATE TOP TO BE N]RUN SHEET OF2 c_ll­,o —IIII- OO I— CF a M /,rK 4T• 4 � �ns� - � LOT 144 ELMHURST DRIVE IIII— — HOMESTEAD VILLAGE O 4" PVC MIN. }` TOWN OF QUEENSBURY WARREN COUNTY,- NEW YORK 00 NOT TO `SCALE NOVEMBER 8, 2013 6"-12" OF SURFACE T, g RAKE ANY EARED PERFORATION ENGINEERING ` LANDSCAPE ARCHITECTURE LAND SURVEYING JOINT 10 JAMES E. MITCHELL P.E. 53,337 TR TRENCH o N _ O.. WALLS '..O VE Q o CRUSHED STONE OR MIN WI GROUNDWATER BEDROCK WASHED GRAVEL OR IMPERVIOUS LAYER %" TO IS` CROSS SECTIONAL VIEW LONGITUDINAL VIEW TENANTED NO. 2 NONWOVEN CONSTRUCTION FABRIC. UNTREATED BUILDING PAPER OR PERMEABLE 1111 II _ iIIIl111 —1111 GEOTEXTHE OR 4" IIII 1 LAYER OF STRAW IIII- -IIII- -I�IIII IIII-�, ��II O U -IIII II. -11, _ O� OO O�J 00 0 as a0 z" Mw. a FLOWPROVIDE CAPS 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 oQ0 0 0 ON LINE ENDS � pp O �� 67Lo � PrP 0 00 SLOPE PIPE &"TA" PER FT. SPACING OF ABSORPTION TRENCH o' O.C. TRENCH BOTTOM TO BE NEAR LEVEL AND RAKED TRENCH PROFILE ABSORPTION TRENCH DETAIL -_n 1 NOT TO SCALE Z n GRADE 0 i NOTE: al FIRE JOINTS TO IBE SEALED WITH F - ASPHALTICMATERIALS OR EQUIVALENT. w 12" MINREMOVABLE COVER 2. INVERT ELEVATIONS OF ALL - OUTLET PIPES- MUST BE EQUAL. o - 3. THE SLOPE OFOUTLET PIPES ti p BETWEEN THE: DISTRIBUTION BOX : 2 AND THE IIDIS.TP13UTOR LATERALS F - SHOULD . BE //8- PER FOOT. w BAFFLE ' U INVERT INLET2'"MIN EL EV. o 0 U TL E T CONTRACTOR TO .USE SPEED LEVELERS Oo 0 AS SUPEN IED BY FORT MILLER TO 2 EQUALIZE FLOW. W I 2" MIN CLEAN SAND OR PEA GRAVEL rc I m W 2` DISTRIBUTION BOX w NOT TO SCALE n! �_ rc Y E ' SHEET OF2 c_ll­,o <2 x SAN/ TAR Y DETAILS FOR a M /,rK 4T• 4 � �ns� - � LOT 144 ELMHURST DRIVE i HOMESTEAD VILLAGE }` TOWN OF QUEENSBURY WARREN COUNTY,- NEW YORK a NOT TO `SCALE NOVEMBER 8, 2013 m '. U,ENVIRONMENTAL DESIGN PARTNERSHIP, LLP f 900 ROUTE 146 CLIFTON PARK, N.Y 112065 (518) 371-7621 ENGINEERING ` LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P.E. 53,337