Loading...
2014-135 ,,A TOWN OF QUEENSBURY Fars 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140135 Date Issued: Tuesday, June 03, 2014 This is to certify that work requested to be done as shown by Permit Number P20140135 has been completed. Location: 9 KILEY Ln Tax Map Number: 523400-295-018-0001-065-000-0000 Owner: STANLEY& JANET WOOD Applicant: STANLEY& JANET WOOD This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or Ceenr7Pl other issues and conditions as a result of approvals by the Planning Board Director of Building a En\ ement or Zoning Board of Appeals. TOWN OF QUEENSBURY Ora742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140135 Application Number: A20140135 Tax Map No: 523400-295-018-0001-065-000-0000 Permission is hereby granted to: STANLEY& JANET WOOD For property located at: 9 KILEY Ln in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: STANLEY& JANET WOOD Deck $2,000.00 9 KILEY Ln QUEENSBURY,NY 12804 Total Value $2,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency • Plans&Specifications 2014-135 DECK 154 sq ft $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,April 28,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) , Dated at the Town o(6ueen ury; 401 1 y 4_. ' 28,2014 SIGNED BY \ for the Town of Queensbury. Director of Building& Code Enforcement Town of Queensbury Building & Codes Off l� %li' tam,. 22 2014 4U ACCESSORY STRUCTURE APPLICATION Rece1i� Tax Map IBik OF QUEENSB„a 5, ”_ - 5. A permit must be obtained before beginning construction ! BUILDINCa?�" PermitNo�: _„- -Thfrz- 3 S For any structure other than residential principal structure(house)to include, but Permit Fee: .5Z1734 not limited to: garage, shed, dock deck, carport, pole barn, greenhouse, etc. Site Plan No.: Refer to Informational Brochure No.3 Accessory Structures-Sheds/Fences f Date " Y `� Applicant 1. i' Tax Map ID Address _) i Zoning •�� A �/ �� /�� g ,,p� Phone ( R/(7 Owner 2"' 'r- Contractor/Agent S Pyr F Address Address Phone Phone Contact Person for Building&Code Compliance: Day Phone: Building Street Address: Subdivision Name: \\ Lot#: Historic Site: Yes No Estimated cost of construction: $ �) TO U '/-L ,/ #n5 Are there any other accessory structures on property? If yes,please list: V "r Type of Construction: Check all that apply Please indicate measurements as required below 1sr Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height Boathouse Boathouse with Sundeck Deck /c /c 27 1 Detached Garage(#of cars_) I Dock Pole Barn Porch-Open "Porch-3 season, Covered,Enclosed Shed ' Other Accessory Structure(s) "Considered floor area& must comply with FAR(Floor area ratio) requirements if located in the Waterfront Residential zone. Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Please include two(2)sets of the following documentation with the application fee: 1. Accessory Structure Application 2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet] a) Indicate proposed structure,showing setback dimensions from all surveyed property lines b) Show location of all existing structures on the property c) Show location of water supply(well or water lines) d) Show location and configuration of septic disposal system or sewer line 3. Structural Drawings to include: Floor Plan; Foundation Plan;Cross Sections; Elevations 4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations with construction costs over$20,000;Any commercial construction Other Notes: 1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are necessary]. 2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. 3. Additional Review-All Applications are subject to Zoning Administrator,Code Compliance, and Structural plan review CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL) Residential Building Code • New driveway requirements for structures located over 300 feet from main road; • Spray foams are allowed to be exposed in rim joist box area only,must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements; • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles; • GFI protection for all other receptacles in kitchens, bathrooms,garages,and unfinished basements; • All receptacles must be tamper resistant; • Carbon Monoxide detectors must be located within 15 feet of sleeping area; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code Requirements • Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant; • Programmable thermostats required; • Lighting must be 50%energy saving light bulbs; • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit; • Res Check inspector's checklist must be available at time of insulation inspection Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statementfdescription of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of al newly constructed facilities prior to issuance of a certificate of occupancy. tel have read and agree to the above Print Name: r ..I Signature: 4111MAMM Date: MIL Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: 41) am/ Depart am/pm Date Inspection request received: In s Initials:am/pal NAME `S-k ✓1 (1—PERMIT#: 1 1 3 5 LOCATION: 9 1 T/ ugA k^ DATE: (9- a,-I S[ TYPE OF STRUCTURE: (3 o G{( Comments: Yes No N/A_ 4" Building Number Address visible from road Chimney Height/13"Vent/Dired Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete I Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: _ Every Bedroom: _ Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing I' hour fire door I door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving UgM Bulbs 50% Final Survey Plot Plan Arc Fauft Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certifcatio uired Okay to issue C/C itC Temporary/Permanent L:IButlding&Codes FormslBuilding&Codeslinspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10, Revised 04/13/11 Town of Queensbury Building &Code Enforcement /��Q� Office No. (518)761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: 54"Qrn 11-u DO cl Inspected on: 5-c?--/A/ Location: 9 f i C 2 (Q /d Arrive: oZ rid a.m./p.m. Permit No.: /'y— /2 5 Inspector's Initials: D tk TYPE OF STRUCTURE: Y N Nin COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams V/ Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %:(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side''/3 inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Ben\ Foundation Inspection Report Office No.(518)761-8256 Date Inspcptiop request received: Queensbury Building&Code Enforcement Arrive: %0 am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: 2)/ NAME: 3k-a e. on a PERMIT#: 3 C LOCATION: 9 Kap A carte INSPECT ON: 9—A3 ,/y TYPE OF STRUCTURE: ,n Q t,K' Comments yN N/A <rFootingsa• Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Buliding&Codes Forms\Building&Codes\InspeWon Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM Lt l_G CX I ii/VG fo eck D 22 U V ip *5/0 6 5 (J 8 1� \m--L3 5 APR 2011vi D ICotcdn r TOWN OFQUEEN$jURy ' RLI❑ I^JC '2. ,s ,lea) oG -, Px�+iendistc a oar oxer e.. d�..✓r t: a7T off yid floe,1 0 k 1 _ ,.-,.....— - emtieder A/ a ote4 . 6A(4 11 A TOW: 1 r,": OUEENSBOkt , , d s ! A Na ii : l,,atid by: .= e iv.._/ TOWN OFOUFEN�BUFW SE" G��r I BUILDING UFpn RTtigEh�?WI ��� �/ �� It on our limiter l'I o9,c)t7filja7s d fia , gie et 6 LnJ\, comm la s.r: ,t IIF. r(1:trtS a as Cyt(; 1 , < F�: 'l FCO! 1 J6 the plans a . ;wA:rt::•,: ;nn. " in iiP *Mb*State.wAh ;ns ,:N,�i�!��� ..::u�� of raj- 135'FAA d a'b / est /� iP 35� STin/ Wait) ,„.„..._,..s. , , 8 ell 0R SI-IE{� 'bogy2014 l , k ---- bbl - z i7 po,..i. f cs u Ile l — — — — — . I j z /Art. i C c [aM Cl 17 ' 16 . +- -.1 u% F— - ------------- -- - / ti fici I 761 id 125 , I Sy" L 0 3 JAI 1 P_ IT PLAN I AVE PERSONALLY MEA' :D THE DISTANCE F THE P'•OPERI INES TO THE P%� ED ST'UCT N(S) `it . (S) OR IGa_"1. GN'TURF DATE Kike.Y I ,,,R.