Loading...
2014-282 TOWN OF QUEENSBURY Ffirkm 742 Bay Road, ueensbu ,NY 12804-5902 (518)Q rY 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20140282 Date Issued: Monday, September 21, 2015 This is to certify that work requested to be done as shown by Permit Number P20140282 has been completed. Tax Map Number: 523400-302-014-0003-040-000-0000 Location: 8 JEROME Ave Owner: MATTHEW T CAMPBELL Applicant: MATTHEW T CAMPBELL This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, , Variance, or other issues and conditions as a result of approvals by the Direc-r of Building&Co. Enfo7kement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: P20140282 Application Number: a20140282 Tax Map No: 523400-302-014-0003-040-000-0000 Permission is hereby granted to: MATTHEW T CAMPBELL For property located at: 8 JEROME Ave in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MATTHEW T CAMPBELL Deck $2,500.00 TRACY L CAMPBELL Total Value 8 JEROME Ave $2,500.00 QUEENSBURY NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2014-282 DECK 384 sq ft $50.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday,July 10,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Que sbury Th :d J, , July 10, 2014 SIGNED BY ` , ` for the Town of Queensbury. Nth Director of Building&Code Enforcement Town Of Queensbury Building & Codes Office Use Only `3O '1 /4_ -46 ACCESSORY STRUCTURE APPLICATION Received: A permit must be obtained before beginning construction Tax Map ID: 01. '" '��,�� Permit No.: km,* r For any structure other than residential principal structure(house)to include, a ` � but Permit Fee: � i ' � not limited to: garage, shed, dock deck, carport, pole barn, greenhouse; tc.O' SKIfl'ibn No.: Refer to Informational Brochure No.3 Accessory Structures-Sheds/Fences Date VI /i'j Applicant MA-nift -' CAmetretr., Tax Map ID 3c'o2 /4-3_y0 Address 7 �rvr • Zoning ,u R Q.reer c , ,v y /2 Say Phone 511gs- 7q/-82b' Owner fle rr/J( .*J C,fyw'f%tt- Contractor/Agent Address i5" Jere,r+.o Au-, • Address a.secv S kk r r N'� 128ogE Phone Sits- 141- gags Phone Contact Person for Building 8&Code Compliance: P14*f t} CP.fesei.L. Day Phone: 5i8-37 k-Szl Y Building Street Address: 0 Jero rrP Auc. ( ,etre 5‘494-fry IJ"( 12FsoA Subdivision Name: Lot#: I Historic Site: Yes \,/ No Estimated cost of construction: $ 237-5-0 Are there any other accessory structures on property? If yes,please list: )t'5, �j1.eC, Type of Construction: Check all that apply Please indicate measurements as required below 1st Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height Boathouse Boathouse with Sundeck Deck XV 3 $ ) c//.6— Detached Garage(#of cars_) Dock Pole Barn Porch-Open 'Porch-3 season, Covered, Enclosed Shed Other Accessory Structure(s) *'F Considered floor area&must comply with FAR(Floor area ratio)requirements if located in the Waterfront Residential zone. Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Please include two(2)sets of the following documentation with the application fee: 1. Accessory Structure Application 2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet] a) Indicate proposed structure, showing setback dimensions from all surveyed property lines b) Show location of all existing structures on the property c) Show location of water supply(well or water lines) d) Show location and configuration of septic disposal system or sewer line 3. Structural Drawings to include: Floor Plan; Foundation Plan; Cross Sections; Elevations 4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations with construction costs over$20,000;Any commercial construction Other Notes: 1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are necessary]. 2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. 3. Additional Review-All Applications are subject to Zoning Administrator, Code Compliance, and Structural plan review CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL) Residential Building Code • New driveway requirements for structures located over 300 feet from main road; • Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements; • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles; • GFI protection for all other receptacles in kitchens, bathrooms, garages, and unfinished basements; • All receptacles must be tamper resistant; • Carbon Monoxide detectors must be located within 15 feet of sleeping area; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code Requirements • Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant; • Programmable thermostats required; • Lighting must be 50%energy saving light bulbs; • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit; • Res Check inspectors checklist must be available at time of insulation inspection Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above Print Name: /1/4-7774- Cfifl47 c - Signature: Date: 7 //Pi Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 /0- -Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/pm Depart:( ) (dam/pm Date Inspection request received: < = Inspector's Initials: • NAME: /t ' 7 ) 6/47/(-1 -1�--- PERMIT#: I LOCATION: s—v eru-1-x--z, 971 _ DATE: r':1 r TYPE OF STRUCTURE: 3? sr � / Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing V rougb-roof minimum 18 inches Roof Complete f` for Einiah-Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall ✓ �y � � Interi• xterior Railings 34 inches to 38 inches • /Handicapped Ramp Compliant --- -' ay from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade -1-(W Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight ��✓�'7` L' Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel c- Duct work sealed properly/Blower Door Test Certification Floor truss,-diliff stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum IA"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/.hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codesllnspection Fomis1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 Town of Queensbury Building & Code Enforcement tkesc �D Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: C Q NA 86-11 Inspected on: i Location: V 4Ser d M Arrive: • r' P a.m./p.m. Permit No.: /q—d' ' Inspector's Initials: TYPE OF STRUCTURE: D e6 K Y % NIA COMMENTS: Framing w' Attic Access 22"x 30"minimum Jack Studs I Headers Truss Specification Provided Bracing/Bridging Joist hangers1/)-- X) 2)— Jack Posts/Main Beams Exterior sheeting nailed properly 2. 12"O.C. t) 0 � Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 11/4(w) 16 gauge(8) 16D nails each side �� Draft stopping 1,000 sq.ft.floor trusses / At- Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 76 , 81°75.7sfabove/below grade 5.0 sf grade Design Professional Sign-off,if required Framing / Firestopping Inspection Report Foundation Inspection Report - I 1/beA Office No.(518)761-8256 Date Inspection request received: � � /a'°j T Queensbury Building&Code Enforcement Arrive: am/pm Depart? j am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials- NAME: ( `tel i MC` •.4:e. PERMIT#: G�/ - LOCATION: '►-v ��,e INSPECT ON: `nAe . 7/i6/1-0 11- TYPE OF STRUCTURE: 3 5�' Comments Y 11j N/A_, ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM �. '3AV 31/11oa r t1 PERMIT PLOT PLAN _.,...."-V.1 �- " I HAVE PERSONALLY MEASURED THE DISTANCE FROM THE PROPERTY LINES TO THE PROPO- D STRUCTURE(S)OR SIVN(S) QN.. ,-N. ., . . . SI !AT iRE DATE . • 4 .".1 V.C> VLS‹ w • m n z • TOWN OF QUEENURY Bur lime examin DEPARTMENT\\\\\�\ • . • Based on our limited exalT?ina ion,c i • with our comments shai:not :- on -' as - • . • •. indicating the plans and specifica .i,. 1e in c) • . • • full compliance with the Building : +1 • • J end 31/1102:13r s cp 11— g� o N li r • / 24.0' 0 W Z t 0 fY �,t Y o 0 U�� p w o_. a I W c 0 a O A210E1 ' a. plE,;,„ , irii / cc0 0 0 J1+EC i L G BACK of 14005erri CceaceerE Gls4C.K (� frkDKktwat 5/1x6," v (i)2'1.4 N A S f ....ir r�.nrrla�rr3.+ri.v-� ta� xf 2 Q K(70714,1) 4) R��EwAy �, effeA5, -- aSTE4 • y x L/ P.1- PoST- I 4.54 6A e Pere 6/ d G raUrti y.Mid It soN4-Tjuu CT)P) 8 or,cy r it Td to : �. , C,,R©vN0 EL&J TO -roe L eco Le-bit Sca►e = l r� 3 5 E SE TluN13 GROUND Poo- 5' oo-s' 4' DEEP o c SONATUBE . — r WITH CONCRETE ° - c • _ • L • iii lo ,, / DIA• PIER FOOTING PLAN SCALE : NTS 31V7S Nb7d rvouvgNooj "171.7Q' hex ')l ,h� �Mo�� s�Y�o,vos Nl SUu.+nloo 3Zvat(-^alag hvo fr sod ' r d17 ;8 I • 1 /7 414\0\n0 911+ c% 3 "7. 133HN�+7d rvoL.f/QNnoj '3NV 3u1obli'' 8 �5 s. = g 3y.DS Nd 7 d 9"/G✓i!L'_i £'3c Ire 3Q,Loi`no'S 3Nab" s4t ) rab AsOi tip-h elk 1 _: 1 1 11 it ;IAA vrxri St130..st 9 \1 e1 xt'- - ( , \,/ IIL733S k , ,aS Wrtoti`0 OY_ 'iC ZIs-Z •gig '-9 rvf l C/X 3 �a3HS rVid V001 j •3rd g _JE(. ome A . X.... 5cr. io V%EVti SNsc-r 'i • 1_XI5Ttt-Q6, 54 o•-.1' , T1 P. R.Atup 5iitif.,1 RAIL CIP 1 n �, i 3�' MWA i �� P`+ 'K ‘/__. ��ln yYyPasT a?-Ab - M�,, Z4 Sash �� N\ _,_ 'r 1- - t--) i ' . '1.4--(--T-'41 - i . r- -OIL „ t.-.A NIA N61 Af °t Si > � I Cara. Svc r r of �� t D 1,. ......A.- ..t. 1 + , Seclon ilA SCS / s_ BIGt Pro Deck DesignTM • 3D View . rot 1, ta . • • ,•• • 4I • • • A. 41, 4 48040 S 40 I�4, it' I4 tff� t+ I 11it1i. I Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC.assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaci6n final del diseno. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informaciOn contenida en esta pagina esta conforme a los tarminos en la negacion,situada en el extremo de este documento. Copyright 01989-2014 Edgenet, Inc. Page 2 of 21 Doc ID 92b611bc-533a-4cc4-8574-e0de689aaB8f J BIG Pro Deck DesignTM Estimate Prepared for: Store Information: MATHEW CAMPBELL 6160 -820 ROUTE 9#6160 8 JEROMWE AVE. QUEENSBURY, NY 12804 QUEENSBURY; NY 12804 5187918285 (518) 798-8301 Estimate Created: 06/28/2014 Days Valid: 14 Estimate Prepared by: JEFFREY Design Systems 8 Decks Total Price (pre-tax): $2,556.17 "Please take this quote to the Contractor Services or Special Services Desk." "Products and prices shown online may vary from those at The Home Depot store near you. Prices shown on this quote may be different due to changes in product availability and market conditions. Prices for identical items may also vary from store to store." "Los productos y precios demonstrados en linea pueden variar de los en el almacen The Home Depot cerca de usted. Los precios demonstrados en esta cotizacion pueden ser diversos debido a los cambios en condiciones de la disponibilidad y del mercado del producto. Los precios para los articulos identicos pueden tambien variar de almacen al almacen." "*Special Order Items where price is not included in total - Please take to The Home Depot Special Services Desk for a price quote." "* Los Articulos de la Orden Especial donde el precio no se incluye en total - Favor de Ilevar a la Mesa de Servicios Especiales del Home Depot para una cotizacion del precio." Warning and Important Instructions: This is not a final design plan or estimate EDGENET. INC.assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacidn final del diseno. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informacidn contenida en este pagina esta conforme a los terminos en la negaciOn,situada en el extremo de este documento Copyright©1989-2014 Edgenet, Inc. Page 1 of 21 Doc ID 92b611bc-533a-4cc4_8574-e0de689aa88f