2014-360 ,,�r�` TOWN OF QUEENSBURY
Nos742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20140360 Date Issued: Monday, November 10, 2014
This is to certify that work requested to be done as shown by Permit Number P20140360
has been completed.
Tax Map Number: 523400-266-001-0001-043-000-0000
Location: 88 FOX Rd
Owner: DAVID SEAMAN
Applicant: DAVID SEAMAN
This structure may be occupied as a:
Porch
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, Gw2E ;
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code nfotcement
Planning Board or Zoning Board of Appeals.
0164 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
` 1 SS
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20140360 Application Number. A20140360
Tax Map No: 523400-266-001-0001-043-000-0000
Permission is hereby granted to: DAVID SEAMAN
For property located at: 88 FOX Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: DAVID SEAMAN Porch $8,500.00
MARYELLEN BISTLINE Total Value
88 FOX Rd $8,500.00
QUEENSBURY, NY 12804
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2014-360
Porch 14' x 16'
$50.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,August 20,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of Q ensb 4 e;n!_,...• August 20, 2014
4
SIGNED BY - \ for the Town of Queensbury.
Director of Building&Code Enforcement
ACCESSORY STRUCTURE APPLICATION -- Office Use Only
�( r
rill c..„ 47 ,_ d Received
DATE !l J 7 l 1 y I f�< I-- -TaiMapID &(e . I Jl —115
TAX MAPID l II it ! AUG 08 20 Perrmi$No. !y —.3 Le 0
ZONING
Permit-Fee °��, V"
M INC `� . :RecFee
I VvvN Cr �:..�. is
HISTORIC SITE Yes .X No I BUILDU C ( , ;_Approvals
SUBDIVISION NAME a C,&.e r r y k, d 5.e Lot# a3 f css
APPLICANT 07�y1 U I(1 S€naJin a le\ OWNER SQ rvn-Q
ADDRESS Sig Foot I�Ls . ADDRESS
OtRercbury in I agoi
PHONE 5 BobQ a @o - 3g 39 PHONE p T
CONTRACTOR yy ✓ b pp Feel n e y jJ I COST OF CONSTRUCTION(ESTIMATED): $ OSQ O
ADDRESS: I D 3 Iu 0 t Th vj e s d- F .BUILDING ADDRESS: S Fo K Rd Due eAs&y
0 ( eetnshury 13 ?
PHONE: C ( g -- 7 y /- 7 ', 9E ,(/ CC,, ^�
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE b R V 1 C.� JU ti c its. PHONE Q..06 -3g O 39
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
Boathouse 1"floor sq.ft. 2ed floor sq.ft. Total sq.ft. Height
Boathouse with Sundeck •
Deck
Detached Garage(trot cars )
Dock
Pole Barn
Porch-open •
"Porch—3 season,Covered,Enclosed 19'r )( '(9 I a 4q /I
Shed V
Other Accessory Structure(s)
Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone
DECLARATION'. I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans and supporting materials are a true&complete statement description of the work proposed,that all work will be
performed in accordance with the NY State Building Codes, local building laws and ordinances; and In conformance with local
zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy. I also understand that Uwe are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of (('U occupancy.,� i I f I
✓I have read and agree to the above: Print Narne: A U 1 CI Se o.vv\ O.v\ Date: s /1 Ji 7
Signature: leafI/l,dAnnt,..�. Date: S I1I 1II-
Town of Queensbury Building&Codes lll"s 1
Accessory Structure Application July 2014
1
Queensbury Building & Code Enforcement - Residential Final Inspection
fin
Office No. (518) 761-8256 Arrive: am/pm D1Z41 rt: ' / am/pm
Date Inspection request received: Inspectors Initials: M .3 69
NAME: PERMIT#:
LOCATION: e �p DATE: / ( /5 --f[4
TYPE OF STRUCTURE: f"-4-
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel ed-Ne
2
Duct work sealed properly/Blower Door Test Certification {^ J
Floor truss,draft stopping finished basement 1,000 sq.R „ 1►k/tr—
Emer en it
g ky egress below grade
Gas Furnace shut-off within 30 feet or within line of site Ott--
Oil
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
G
Garage firepr000fingng/'/,/ hour fire door/door closer
_GtX
s hnaled or Glass Enclosure
'nal lectricaa Energy Saving Light Bulbs 50%
Final purvey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
PlainCertification,Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:1Building&Codes Forms\Building&Codes\Inspection Fonns\Residential Final Inspection Forn_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
Town of Queensbury Building & Code Enforcement I a t 3 a /
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection request received:
Name: S eQMQ,r1 Inspected on: 9-3 - yt
Location:
FaX Arrive: a.m./p.m.
Permit No.: /</-3 (AO Inspector's Initials: Cif-AR
TYPE OF STRUCTURE: Ptd
J N NIA COMMENTS:
`Ataming'
Attic Access 22"x 30"minimum
Jack Studs!Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers .--
Jack Posts/Main Beams
Exterior sheeting nailed properly V/
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more •
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w)16 gauge(8)16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 518 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space!Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing / Firestopping Inspection Report
Town of Queensbury Building &Code Enforcement 2
Office No. (518) 761-8256
Framing /c{Firestopping Inspection Report
Inspection request received: q('s/t p�
Name: �> � UAr Inspected on: / Lo
Location: $`j5 fC R-Ot Arrive: a.m.I p.m.
Permit No.: CQ 0 Inspector's Initials:
TYPE OF STRUCTURE: 1ecGN
Y I N N/A COMMENTS:
Xraming e(0Oi -19 i 5rS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing 1 Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/Firestopping Inspection Report
I- 3
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: l C�
/w c L/
Queensbury Building& Code Enforcement Arrive: /p
CCy�, Qam/pm Depart2, t
742 Bay Rd., Queensbury, NNY__ 12804 Inspector's Initial / �
NAME: J 'v /\I �I^ PERMIT#: / -3 `t" 0/j
LOCATION: �� t—aK t'Z J-� INSPECT ON: 1 / /i)-
TYPE OF STRUCTURE: (Dtt(.(+ l
I Comments
Yr N N/A
ootings I
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM \//
Town of Queensbury Building &Code Enforcement
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection request received:
Name: M i l \% J -S Inspected on: 9- -.u<
Location: h rndd0/1 Arrive: a.m./p.m.
Permit No.: R-t — 0 Inspector's Initials: lk
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
Attic Access 2T x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing I Bridging �'
auk.CLek
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12'O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
.n. ater`se :Id 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/Firestopping Inspection Report
Town of Queensbury Building & Code Enforcement i.��,,a1 u
Office No. (518) 761-8256 W(� ' ��
( 3r.v5-
Framing / Firestopping Inspection Report ci r?..)
Inspection request received: / (�
Name: N\ r�.;}s e(S. r-0 u43 Inspected on: `7 `3
�
Location: I0 O I co n 1� Arrive: A" a.m./p.m.
Permit No.: / 24o Inspector's Initials:
TYPE OF STRUCTURE: If h Se
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12°O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in..
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %:(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses �
Anchor Bolts 6 ft.or less on center AT Qs p`- 419
101Mttion 1,2!3 inches from wall } k 2cr5 �7 )..4‘
Fire separation 1,2,3 hour
L
Fire wall 2,3,4 hour /a t`lv \r`'` ��-< ` 5, W-/ L-
Firestopping
Penetration sealed
16 inch Fiinsulation in cavity min. R-C7 cc,
Garage Fire Separation ����3
Houseg sidYi8inor h5y8 pinXhTypeX f J� � ' h
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W) o —
5.7 sf above/below grade
5.0 sf grade r � e
Design Professional Sign-off,if required <a` _c
v�
Framing I Firestopping Inspection Report � � `
t rielaq / ' 'a
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: \ am/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initialdrl t
)
NAME: � 1(..AN titdolls' PERMIT#: /<f 3&,Z)
LOCATION: /01neq INSPECT ON: g 'c).9—/ y
TYPE OF STRUCTURE: 1yl hseo
Comments
N N/A
Footings
er
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM