Loading...
2014-364 TOWN OF QUEENSBURY Fora 742 Bay]toad,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140364 Date Issued: Wednesday, January 21, 2015 This is to certify that work requested to be done as shown by Permit Number P20140364 has been completed. Location: 310 DIXON Rd Tax Map Number: 523400-302-009-0001-001-000-0000 Owner: 310 DIXON RD. ENTERPRISE, LLC Applicant: PAUL & TERI SCHUERLEIN This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property C`� owner of the responsibility for compliance with Site Plan, Variance, or , J other issues and conditions as a result of approvals by the Planning Board Director of Building& e En ement or Zoning Board of Appeals. TOWN OF QUEENSBURY vers 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140364 Application Number: A20140364 Tax Map No: 523400-302-009-0001-001-000-0000 Permission is hereby granted to: PAUL& TERI SCHUERLEIN For property located at: 310 DIXON Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PAUL& TERI SCHUERLEIN Commercial Alteration $200,000.00 162 PALISADES Rd Total Value BRANT LAKE,NY 12815-0000 $200,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2014-364 Comm. Alterations 1,756 sq ft- convert plumbing office &warehouse into medical office $351.20 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,August 26, 2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the exiration date.) Dated at the Town of Qu stn;41 T •• 4• • ugust 26, 2014 7 i SIGNED BY Sok for the Town of Queensbury. Director of Building&Code Enforcement `� PRINCIPAL STRUCTURE APPLICATION Office Use Only l_ f I, DATE 3 1 t 01.A I r I 3L k`; is.. d .y L Received v Tax Map ID 3602,4-1- led, oh¢d 3 O Ur 1I Ir.+ Per it No. gs- 02,0)/4- 31(4 CO`' TAX MAP ID �O^ ` ' ` 1` ``'?'t 1.�i7 1 2 2014 P-ermit Fee 3 5(. ?o I &J Rel Fee h.�0.- ZONWG l f_'" OF QUEENSBURY a I BUILDING &CODES Site Plan# SPS- ao l� U✓rawly HISTORIC SITE Yes No 'Subdivision # SUBDIVISION NAME Lot# TOWN Ba RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. t _ APPLICANT C,cone. CG "sr. Cv • OWNER ,"' aoL ern 5c itueiUdt 4 ADDRESS \aik "Pprrts iRov=to ADDRESS 1LP p. ? .0 S e s ?-O - Q'.�..e�ns&uN I E.4l.(. 1z W4 ?) ArVVC L Aa cee- , Ny \-z-815 ` PHONE/E-MAIL ACA ECxe•e- vX `one . CoM PHONE/E-MAIL SX.8 - 3(05 - 0 C 4 CONTRACTOR '\` oAt Covts�'• CCO • COST OF CONSTRUCTION(ESTIMATED): $ TS C^t. '� C ADDRESS: ' a"C Q ''S Septa BUILDING ADDRESS: 3\ID XA rI - Qv�ee\nSb tt t-1 f 12914 `` `-'t� z PHONE/E-MAIL *ICA a-aa•4ka CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: \--‘441-1 C% Co h C PHONE 3(01-a(oZ‘) (� aget;tw^/ lS nit +n -�v tendlick arT dl t / At--,i, -.5 e . 4136. l P .S TYPE OF CONSTRUCTION d-a[5 ZEA if-r, ce t ./� ziM A ` .. GG7 , -, /^'.S "„P Lt.Q i 08 LSP Check all that apply Please indicate measurements as requir-d below New Addition Alteration 1s1 floor sq.ft. 2ntl floor sq.ft. Total sq.ft. Height Single Family Two-Family Multi-Family (# ■---_�- (#of units_) Town . - • Pitin-NEWAREMEM ,PMEIM 4 Business Office 19 (� . I 'co_ N yin a �l-�. •le,--r�r,.�.�ia� Factory- Industrial Attached Garage ■---_-- Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 �•,� ^If commercial or industrial indicate name of business ('vu r racAc it Proposed use of building or addition Source of heat (circle one) Gas Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances& Chimneys Are there structures not shown on plot plan? LD 0 Are there easements on the property? N 13 Site Information a. Dimensions or acreage of lot at b. Is this a corner lot? {� c. Will the grade be changed as a result of construction _Yes No d. Public water or Private well Pubv,c, e. Sewer or Private Septic System 5.4a-vTl C_, Value of all work to be performed (labor or materials) $aSSaa1cj, DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: AAc Cc-t- � FO t1/41C DATE p \ \ I* ���- SIGNATURE: - 5C� DATE 81 1,141 FOR OFFICE USE ONLY • Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 SEPTIC DISPOSAL PERMIT IOffice Use Only ' `f DATE el Li t I Received Tax Map ID TAX MAP ID �09-n2, 3 PernitNo. 1 )4-:i(051 2 T Permit Fee LOCATION OF INSTALLATION 3tD I\ Xq YL � Approvals: APPLJCANT" / l .l1-OvIe . � L! YIST: /o . PHONE/E-MAIL 5t2 -19 a - Rack a ADDRESS t a+-k ?a-riC-- Roo 6 . Qvee-dnt\OON.j I4 va 8C4 INSTALLER/BUILDER: CA c*,ne. Corrisr. 0 0• PHONE/E-MAIL ADDRESS: \a* C-A'I-kCcad t QueenS\o'r�-c -: -t \aQvo�C{�s�( ___OWNER RPel>L.► \.errs 1nuerL.:e_NI PHONE/E-MAIL 1fa -- (05- v—I—f4 Address lea Rai:,, SA&eS\I- mer.' + � . -H � \a4 5 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1✓\ATi cC C o'na PHONESCI'tba(c) RESIDENCE INFORMATION /// Year Built #of bedrooms X Gallons per bedroom =Total Daly Flow 4:0 tyc t / .,.4 \4 1 etki 1980 or older Garbage grinder installed` V XN 1981-1991 Spa or Hot Tub installed _Y 66 1992-Present PARCEL INFORMATION Topography Flat rolling —Steep slope %slope Soil Nature 4.Sand —Loam —Clay —Other Groundwater At what depth? 2 6 • Bedrock/Impervious Material At what depth? _ ( 44 Domestic Water Supply K Municipal Well(if well,water supply from any septic system absorption is—It) Percolation Test Rate: 1-Srdt1 pal per inch(test to be completed by licensed engineering/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank Size \r allons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hot tub) System Type Absorption field with#2 stone Total length \'7'S ft.: Each trench '' x A Seepage Pit with#3 stone How many: :size Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size . #of tanks Notes: 1)Alarm system&associated electrical wont must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an AS-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. 1 DECLARATION: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide these and all requirements of the Town of Queensbury Sanitary Sewage Disposal rdinance. Print Name: S i Date: Signature: V Date 6 Town of Queensbury Building&Codes Principal Structure Application July 2014 ToVvn of Queensbury Building&Code Enforcement Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: %CJhu,c r1 P,(A Inspected on: /0l0—! S Location: '31 o 1l l(o yi Arrive: f'y ) a.m.lp.m. Permit No.: /z/-%3La `P Inspector's Initials: 1sU An�l�� E 3 t r .367a COMMENTS O Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"I Roof Complete Exterior Finish I Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch/Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch w/Lever Handles I Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'A doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18°x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible ✓ Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/Drivable Surface 20'wide Special Inspections I Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O ✓ Okay To Issue C/C Commercial Final Inspection_11 2712 Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: S 0)4V2r1 e,1 /i Inspected on: /74-1—/5 Location: 31 D k7 I Xt5 n Rd%. Arrive: a.m.f p.m. Permit No.: / / — 3 Cc ' Inspector's Initials: • COMMENTS Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"I Roof Complete Exterior Finish!Grade Complete 6"in 10'or Equivalent Intenor/Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch/Step Risers 7"I Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch wlLever Handles 1 Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight!Other Floors Okay Relief Valve, Heat Trap I Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'V2 doors >10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers 1 Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, it required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure I Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/Drivable Surface 20'wide /� �� Special Inspections/Engineer or Architect Approval f/ !/ /( ' & lei Okay To Issue Temporary or Permanent C/O CQ.U.Cu l Okay To Issue C/C (Crz3 .!(LLI(j Al Commercial Final Inspection_!! 2712 RX DatelTime 01110/2015 1221 18019329469 r.Dlo To Attn Dave Hattin Page 15 of 15 2015-01-10 17 17.48(GMT) 18019329469 From: Douglas Kwazneski F ICYNENE" THE EVOLUTION OF INSULATION INSULATION CERTIFICATE . ,4-j,2 },a x This form must be filled outand posted to comply with building code-requirements. 79S q-!31 Meets IRC requirements: 2006 IRC-N1101.2,N1101.4,N1101.8 2009 IRC-N1101.2,N1101.4,NI 1012 2012 IRC-N1101.3,N1101:7,N1101.12 The following spray polyurethane foam products)has/have been installed. a'LD-C-50 OLD-R.50 Jgj MD-C-- 00 0-MD-R-200 ❑ MD-R-210 0 Other ✓2 C_,!1sstc Ftc 1V3 f*0SeA-L Please consult International Building Code(IBC),Chapter 26-Plastic and International Residential Code(IRC) 2006 IRC R314.2009 IRC R316,2012 iRC R316-Foam Plastics for specific requirements.The aforementioned Icynene Spray polyurethane foam insulation system(s)has/have been installed in accordance with manufacturer's processing_guidelines to provide a thermal resistance of: Area insulated Aged R-Value Thickness{ Attic Area R- at Inches /0 Sloped Ceilings icor R- S I at /o,5inches 0 Walls(location): --f c_a_41.•31, rids IJS R- 20 at- 5,S inches t_.0css.e i&mg, Walls(location): Ci[Tettecie- eC t-!(5 R- 121 I at 3,t1' inches - G toe, Floors(over an unheated crawl space) R- at inches V3 T"o ff-,*c_. Craw€Space Perimeter R- at I I inches -L-c-:$50 Faft1-q Basement Walls R- I I at I inches Other(location): R- I I at inches `Nominal thicknesses are representative offield,xpray-applled foam material. Jobsite Address vn.co ee. teur-st3v 1 /.1t - C Ie o,A/L.¢e-`Erb, CFFtC- Date of Insulation Installation 7- 2oP-1 Building Contractor I Cr slr6.wtic-TON-1 Insulation Contractor kb.?4_44. L.46 r 5/4_4-7 -71-em 44 Insulation Contractor Phone 7 C,23 701 Installed ,Sy 0 Vi0 2a-A te_CoA J 4pft La -fp 4-1 GPcx-i-Cccc. ' r144 INSULATION CERTIFICATE * DO NOT REMOVE Please post near electrical panel. ICYNENE Inc. • 6747 Campobello Road,Mississauga ON LSN 2L7 Canada ICYNENE.COM RX DatelTime 01110/2015 12:21 18019329469 P.001 To: Attn: Dave Hattin Page 1 of 15 2015-01-10 17:17 48(GMT) 18019329469 From. Douglas Kwazneski FAX COVER SHEET TO Attn: Dave Hattin COMPANY Queensbury code enforcement FAX NUMBER 15187454437 FROM Douglas Kwazneski DATE 2015-01-10 17:1721 GMT RE chiropractic office/ Dixon road Queesbury, NY COVER MESSAGE Site certificate and ESR's As per ESR-1826, section 4.4.1.2.2, application of thermal and/or ignition barrier not required in attic aroos. Vapor Retarder coating has been applied to all open cell foam. Douglas Kwazneski North East Spray foam 518.796.5821 • WWW.EFAX.COM RX Date/Time 01/10/2015 1221 18019329469 P.002 To Attn Dave Hattin Page 2 of 15 2015-01-10 17 17 48(GMT) 18019329469 From: Douglas Kwazneski • ES ICC EVALUATION �, SERVICE - Most WidelyAccepted and Trusted ICC-ES Evaluation Report ESR-3500 Issued January 1, 2014 This report is subject to renewal January 1, 201.5 www.icc-es.orq (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE may be used in fire-resistance-rated construction when PROTECTION installed in accordance with Section 4.5, and in Types I Section:07 21 00—Thermal Insulation through IV construction when installed in accordance with Section 4.6 REPORT HOLDER: 3.0 DESCRIPTION ICYNENE, INC. 3.1 ProSeal(MDL-200V3) Insulation: 6747 CAMPOBELLO ROAD Icynene ProSeal (MD-C-200V3) foam plastic insulation is MISSISSAUGA,ONTARIO L5N 2L7 a two-component, medium-density, closed-cell, spray- CANADA applied foam plastic with a nominal density of 2.4 pcf_ The (905) 3634040 polyurethane foam is produced by combining Icynene • www.icvnene.com Based Seal MDI isocyanate (the A component) and Jevanstbicvnene.com Icynene ProSeal (MD-C-200V3) resin (the B component). The products have a shelf life of 12 months when stored in EVALUATION SUBJECT: factory-sealed containers at temperatures between 60°F and 85°F (16°C and 29°C). The Icynene ProSeal (MD-C- ICYNENE PROSEAL(MDL-200Vro) 200V3)is supplied in one formula for all climates. 1.0 EVALUATION SCOPE 3.2 Surface Burning Characteristics: Compliance with the following codes: The Icynene ProSeal (MD-C-200V3) insulation, at a maximum thickness of 4 inches (102 mm) and a nominal • 2012 and 2009 International Building Code(IBC) density of 2.4 pcf, has a flame-spread index of 25 or less • 2012 and 2009 International Residential Code(IRC) and a smoke-developed index of 450 or less when tested in accordance with ASTM E84. • 2012 and 2009 International Energy Conservation Code® 3.3 Thermal Resistance: (/ECC) Properties evaluated: Icynene ProSeal 00V3) insulation has a thermal resistance, R-value,e, atata mean temperature of 75°F(24°C) • Surface-burning characteristics as shown in Table 1. • Physical properties 3.4 Air Permeability: •Thermal resistance(R-values) Icynene ProSeal (MD-C-200V3) insulation, at a minimum 1.4-inch (356 mm) thickness, is considered air- •Attic and crawl-space installation impermeable insulation in accordance with 2012 IRC •Air permeability Section R806 5 (2009 IRC Section R806.4), based on testing in accordance with ASTM E2178. •Vapor permeability 3.5 Vapor Permeability: • Fire resistance Icynene ProSeal (MD-C-200V3) insulation has a vapor • Exterior walls of Types I–IV construction permeance of less than 1 perm (5.7x10-11 kglPa-s-m2)at a 2.0 USES minimum thickness of 1.5 inches (38.1 mm) and may be used where a Class II vapor retarder is required by the Icynene ProSeal (MD-C-200V3) spray foam is used as a applicable code. nonstructural thermal insulating material in Types I, II, III, IV and V construction under the IBC and dwellings under 3.6 Intumescent Coatings: the IRC The insulation is for use in wall cavities, floor 3.6.1 DC 315: DC 315 intumescent coating, , assemblies, ceiling assemblies, or attics and crawl spaces manufactured by International Fireproof Technology, Inc, when installed in accordance with Section 4.4 Under the is a water-based coating supplied in 5-gallon (19 L) pails IRC, the insulation may be used as air-impermeable and 55 gallon (208 L) drums. The coating material has a insulation when installed in accordance with Section 3 4, shelf life of 24 months when stored in factory-sealed and as a vapor retarder when installed in accordance with containers at temperatures between 41°F (5°C) and Section 3 5. lcynene ProSeal (MD-C-200V3) spray foam 95°F(35°C) ICC-ES Evaluation Reports are not to be construed as represeatng aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommend on on for us use here is no warranty by ICC Evaluation Service,LEG;express or implied,as to any finding or other eater in this report,or as to any product covered by the report Copyright C 2014 Page 1 of 4 RX DatelTime 01/10/2015 12:21 18019329469 P.003 To Attn: Dave Hattin Page 3 of 15 2015-01-10 17 17 48(GMT) 18019329469 From: Douglas Kwazneski ESR-3500 [ Most Widely Accepted and Trusted Page 2 of 4 3.6.2 Pyroguard: Pyroguard intumescent coating, with the coating manufacturer's instructions and this report. manufactured by Paradigm Labs, is a water-based coating Surfaces to be coated must be dry, clean, and free of dirt, supplied in 5-gallon (19 L) pails and 55-gallon (208 L) loose debris and other substances that could interfere with drums. The coating material has a shelf life of 24 months adhesion of the coating The coating is applied in one coat when stored in factory-sealed containers at temperatures with low-pressure airless spray equipment. between 41°F(5°C)and 95°F (35°C) 4.4 Attics and Crawl Spaces: 4.0 DESIGN AND INSTALLATION 4.4.1 Application with a Prescriptive Ignition Barrier: 4.1 General: When Icynene ProSeal (MD-C-200V3) insulation is installed within attics or crawl spaces where entry is made Icynene ProSeal (MQG200V3) must be installed in be accordance with the manufacturers published installation only for insaccordancevice of utilities, anIignition barrier must or instructions, this report and the applicable code The installed in with IBC Section 2603 4 1 6 or manufacturers published installation instructions and this IRC Sections R316.5.3 and R316.5.4, as applicable. The report must be strictly adhered to, and a copy of the ignition barrier must be consistent with the requirements instructions and this evaluation report must be available on for the type of construction required by the applicable the tobsde at all times during installation code, and must be installed in a manner so that the foam plastic insulation is not exposed Icynene ProSeal (MD-C- 4.2 MD-G4.2 Application: 200V3) insulation may be installed in unvented attics in Icynene ProSeal (MD-C-200V3) must be applied using accordance with 2012 IRC Section R806 5 (2009 IRC spray equipment specified by Icynene, Inc. The insulation Section R806.4). must not be used in areas having a maximum service 4.4.2 Application without a Prescriptive Ignition temperature greater than 180°F(82°C), must not be used Barrier: Where Icynene ProSeal (MD-C-200V3) spray in electrical outlet or)unction boxes or in contact with rain foam is installed in an attic or crawl space without a or water, and must be protected from the weather during prescriptive ignition barrier, in accordance with Sections and after application Where Icynene ProSeal (MD-C- 4.4.2.1 and 4.4.2 2,the following conditions apply: 200V3) is used as an air-impermeable barrier, such as in 1 Entry to the attic or crawl space is only for the service unventilated attic spaces regulated by IRC Section R806, of utilities and no storage is permitted. the insulation must be installed at a minimum thickness of 1.4 inches (35 6 mm). The insulation S applied to the 2 There are no interconnected attic, crawl space or intended thickness, with the first pass being a maximum basement areas. of 3 inches (76 mm) and all additional passes being a 3 Air in the attic or crawl space is not circulated to other maximum of 2 inches (51 mm) Where multiple passes are parts of the building. required, the cure time between each pass is in accordance with the manufacturers instructions. 4. Combustion air is provided in accordance with IMC (International Mechanical Code®)Section 701 4.3 Thermal Barrier: 5 Attic ventilation is provided when required by IBC 4.3.1 Application with a Prescriptive Thermal Barrier. Section 1203.2 or IRC Section R806, except when air- Icynene ProSeal (MD-C-200V3) spray foam insulation impermeable insulation is permitted in unvented attics must be separated from the interior of the building by an in accordance with 2012 IRC Section R806.5 (2009 approved thermal barrier, such as h-inch-thick(12.7 mm) IRC Section R806.4) gypsum board installed using mechanical fasteners in accordance with the applicable code, or an equivalent 6 Under-floor (crawl space) ventilation is provided when 15-minute thermal barrier complying with, and installed in required by IBC Section 1203.3 or IRC Section R408.1, accordance with, IBC Section 2603.4 or IRC Section as applicable. R316.4, as applicable When installation is within an attic 4.4.2.1 Attics and Crawl Spaces — Uncoated: The or crawl space as described in Section 4.4, a thermal thickness of the foam plastic applied to the underside of barrier is not required between the foam plastic and the the roof sheathing and/or rafters,or the underside of floors, attic or crawl space, but is required between the insulation must not exceed 8 inches (203 mm) The thickness of the and the interior of the building. There is no thickness limit spray foam insulation applied to vertical wall surfaces must when installation is behind a code-prescribed thermal not exceed 6 inches (152 mm) The insulation does not barner except as noted in Sections 4.4.2 1, 4 4 2.2 and require a code-prescribed ignition barrier or coating. 4.4.3 4.4.2.2 Attic and Crawl Spaces-Coated: The thickness 4.3.2 Application without a Prescriptive Thermal of the foam plastic applied to the underside of the roof Barrier. Icynene ProSeal (MD-C-200V3) may be installed sheathing and/or rafters, or the underside of floors, must without the 15-minute thermal barrier prescribed in IBC not exceed 14 inches (356 mm). The thickness of the Section 2606 4 and IRC Section R316.4, when the spray foam insulation applied to vertical wall surfaces must installation is in accordance with this section. The not exceed 8 inches(203 mm). insulation and coating may be spray-applied to the interior facing of walls, the underside of roof sheathing or roof The Icynene ProSeal (MD-C-200V3) insulation must be rafters, and in crawl spaces, and may be left exposed as covered on all surfaces with either: an interior finish without a 15-minute thermal barrier or DC315' at a minimum dry film thickness of 3 mils ignition barrier The thickness of the insulation applied to (0.08 mm) [wet film thickness of 4 mils (0.10 mm)] at a the underside of the roof sheathing must not exceed rate of 401 square feet(37 m2)per gallon(3.8 L). 14 inches (356 mm). The thickness of the insulation applied to vertical wall surfaces must not exceed 8 inches Pyroguard: at a minimum dry film thickness of 4 mils (203 mm). The insulation must be covered on all surfaces (0.10 mm) [wet film thickness of 7 mils (0 175 mm)] at a with DC 315 coating at a minimum wet film thickness of rate of 229 square feet(21 m2)per gallon(3.8 L) 24 mils(16 mils dry) The coating must be applied over the The coating must be applied over the Icynene ProSeal Icynene ProSeal (MD-C-200V3) insulation in accordance (MD-C-200V3) insulation in accordance with the coating RX DatelTime 01/10/2015 1221 18019329469 P.004 To- Attn. Dave Hattan Page 4 of 15 2015-01-10 17 17:48(GMT) 18019329469 From: Douglas Kwazneski ESR-3500 I Most Widely Accepted and Trusted Page 3 of 4 manufacturer's instructions and this report. Surfaces to be the long end perpendicular to the steel studs, using No. 6, coated must be dry, clean, and free of dirt, loose debris Type S, 11/4-inch (31 7 mm), self-tapping bugle head and other substances that could interfere with adhesion of screws spaced 8 inches (203 2 mm) on center around the the coating The coating is applied in one coat with low- perimeter and in the field The stud cavity is filled with pressure airless spray equipment Icynene ProSeal (MD-C-200V3) insulation to a maximum 4.4.3 Use on Attic Floors: Icynene ProSeal (MD-C- nominal thickness of 6 inches 200V3) insulation may be installed exposed at a maximum 4.6.3 Interior Face: Type X gypsum board, 5/8 inches thickness of 14 inches (356 mm) between and over the (159 mm) thick and complying with ASTM C1396, is joists in attic floors The insulation must be separated from installed, with the long dimension perpendicular to steel the interior of the building by an approved thermal barrier studs, with No. 6, Type S, 11/4-inch-long (31 7 mm), self- An ignition barrier in accordance with the IBC Section tapping bugle head screws spaced 8 inches (203 mm) on 2603.4 and IRC Section R316 5 3 may be omitted center around the perimeter and 12 inches(305 mm)in the 4.5 One-hour Non-load-bearing Fire-resistance-rated field. The gypsum board joints must be treated with vinyl or Wall Assembly: casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board 4.5.1 Exterior Face: Nominally 6-inch-deep (152 mm), butt joints. A minimum 2-inch-wide (51 mm) paper, plastic, No. 18 gage galvanized steel studs, spaced 16 inches or fiberglass tape is embedded in the first layer of (406 mm) on center, are fastened to No 18 gage compound over butt joints of the gypsum board galvanized steel floor and ceiling tracks. One layer of /2-inch-thick (12 7 mm) Georgia Pacific DensGlasr Gold 4.6.4 Exterior Wall Covering: Details of the exterior wall Exterior Sheathing is installed parallel to the steel studs covering must be provided to the code official by the report with vertical joints offset a minimum of 16 inches(406 mm) holder, designer or specifier, with an engineering analysis from the vertical joints of the interior Type X gypsum board, demonstrating that (1) the exterior wall covering conforms and the horizontal joints offset a minimum of 24 inches to ASTM E136 and (2) the addition of the wall covering to (610 mm) from the horizontal joints of the gypsum board. the assembly described in this section does not negatively The sheathing is attached using 11/4-inch long (31 7 mm), affect conformance of the assembly with the requirements self-drilling drywall screws spaced 8 inches (203 mm) of IBC Section 2603.5. on center around the perimeter and in the field. Hohmann 5.0 CONDITIONS OF USE & Barnard DW-10 brick ties, 6 inches (152 mm) long by 11/2 inches (38 mm) wide, are spaced 16 inches The Icynene ProSeal (MD-C-200V3) spray foam insulation (406.4 mm) on center vertically on each steel stud, and described in this report complies with, or is a suitable secured using two 15/8-inch-long (41.3)self-drilling screws, alternative to what is specified in, those codes listed in through 4-inch (102 mm) red clay brick [31/2 inches Section 1.0 of this report, subject to the following (889 mm) by 21/4 inches (571 mm) by 73/4 inches conditions: (197 mm)I, laid in a running bond pattern with Type S mortar, leaving a nominally 1-inch (25 4 mm) air gap 5.1 The product must be installed in accordance with between the brick and the exterior sheathing. The stud the manufacturers published installation instructions, cavity is filled with Icynene ProSeal (MD-C-200V3) this evaluation report and the applicable code In the insulation to a maximum nominal thickness of 6 inches event of a conflict between the manufacturer's published installation instructions and this report, this 4.5.2 Interior Face: Type X gypsum board, 5/8 inch report governs. (159 mm) thick and complying with ASTM C1396, is applied to the interior side with the long edge parallel to 5.2 The insulation must be separated from the interior of steel studs, and is secured using 11/4-inch-long (31] mm), the building by an approved 15-minute thermal barrier self-drilling drywall screws spaced 8 inches (203 mm) on in accordance with IBC Section 2603 4, except when center around the perimeter and 12 inches (305 mm) on installation is as descnbed in Section 4 3.2 or in attics center in the field. The gypsum board joints must be and crawl spaces as described in Section 4.4.2. treated with vinyl or casein, dry or premixed joint 5.3 The insulation must not exceed the thickness and compound applied in two coats to cover all exposed screw density noted in Sections 3 2, 4.3, 4.4, 4.5 and 4 6 of heads and gypsum board butt joints. A minimum 2-inch- this report wide (51 mm) paper, plastic, or fiberglass tape is embedded in the first layer of compound over butt joints of 5.4 The insulation must be protected from the weather the gypsum board. during and after application. 4.6 Exterior Walls in Type I, II, III and IV Construction: 5.5 The insulation must be applied by installers certified 4.6.1 General:When used on exterior walls of Types I, II, by Icynene, Inc. III or IV construction, the assembly must comply with IBC 5.6 Use of the insulation in areas where the probability of Section 2603 5 and this section, and the Icynene ProSeal termite infestation is 'very heavy" must be in (MD-C-200V3) insulation must be installed at a maximum accordance with IRC Section R318.4 or 2012 IBC thickness of 6 inches (152 mm) The potential heat of Section 26039 (2009 IBC Section 2603.8), as Icynene ProSeal (MD-C-200V3) insulation is 2785 Btu/ft2 applicable. (31 629 kJ/m2) per inch of thickness, when tested in accordance with NFPA 259. 5.7 Jobsite certification and labeling of the insulation must 4.6.2 Exterior Face: Nominally 6-inch-deep, Na. 18 comply with IRC Sections N1101 4 and N1101.41 and IECC Sections 303.1.1 and 303.1 2, as gage, galvanized steel studs, spaced 16 inches (406 mm) applicable. on center, are fastened to No 18 gage galvanized steel floor and ceiling track using No. 8, 2/8-inch-long (22.2 mm), 5.8 The A and B components of the insulation are self-tapping, pan head framing screws. Georgia Pacific produced under a quality control program with DensGlase Gold Exterior Sheathing, 1/2 inch (12 7 mm) inspections by ICC-ES and CAI Laboratories Inc thick, is installed over the exterior side of steel studs with (AA-723). RX Date/Time 01/1012015 12:21 18019329469 P.005 To Attn Dave Hattin Page 5 of 15 2015-01-1017.17 48(GMT) 18019329469 From. Douglas Kwazneslo ESR-3500 I Most Widely Accepted and Trusted Page 4 of 4 • 6.0 EVIDENCE SUBMITTED 6.7 Report of a potential heat test in accordance with 6.1 Data in accordance with the ICC-ES Acceptance NFPA 259. Criteria for Spray-applied Foam Plastic Insulation, 6.8 Report of a critical radiant flux test in accordance with (AC377), dated November 2012 (editorially revised ASTM E970. April 2013), including reports of tests in accordance 7.0 IDENTIFICATION with Appendix X of AC377 6.2 Report of air permeance test in accordance with Containers of Icynene ProSeal (MD-C-200V3)components ASTM E2178. _ are identified with a label bearing the Icynene, Inc., name and address, the product trade name [Icynene ProSeal 6.3 Report of vapor permeance test in accordance with (MD-C-200V3)), the lot number, the flame spread and ASTM E96 smoke developed indices, moving instructions, density; the 6.4 Engineering analysis of a fire-resistance test in shelf life and the expiration date, the evaluation report accordance• with ASTM E119. number (ESR-3500); and the names of the inspection bodies(ICC-ES and QAI Laboratories Inc.) 6.5 Engineering analysis of a fire test in accordance with Intumescent coatings are identified with the NFPA 285 manufacturers name and address, the product trade 6.6 Report of a room corner fire test in accordance with name and use instructions NFPA 286. TABLE 1—THERMAL RESISTANCE(R-VALUES) THICKNESS (inches) R-VALUE(°F.ft'.hlBtu) 1.0 7 0 3.5 24 4.0 27 5 5 38 60 41 75 51 8.5 58 9.5 65 10.0 68 11.25 77 For SI:1 inch=254 mm; 1°F 112.h/Btu =0176110°K nf.hlW. 1R-values are calculated based on tested K-values at 1-and 3 5-inch thicknesses 'R-values greater than 10 are rounded to the nearest whole number RX Date/Time 0111012015 12:21 18019329469 P.006 To:Attn Dave Hattin Page 6 of 15 2015-01-10 17:17 48(GMT) 18019329469 From: Douglas Kwazneski Ea. ICC-EVALUATION Most Widely Accepted and Truster/ •,�. SERVICE . ICC-ES:Report ICC-ES 1 {800)423-6587:05.62 694 0543 ( www tcc-es org Valid 02J13 to 02/15; re. DIVISION:07 00 00-THERMAL AND MOISTURE PROTECTION SECTION:'07 2100-THERMAL INSULATION REPORT HOLDER: ICYNENE,,INC::,_ 6747 CAMPOBELLO ROAD MISSISSAUGA,ONTARIO 15N CANADA EVALUATION SUBJECT: ICYNENE CLASSIC, CLASSIC MAX, CLASSIC ECO AND CLASSIC • ;.. ICC ICC ICC , MG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC)Award in Excellence" A Subsidiary of isua or ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically /� addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LW, express or implied, as to any finding or other matter in this report, or as to any product covered by the report PitaCala Copyright© 2014 RX Date/Time 01110/2015 1221 18019329469 P.007 To. Attn Dave Hattin Page 7 of 15 2015-01-10 17 17.48(GMT) 18019329469 From: Douglas Kwazneski • tf+S ICC EVALUATION. • `� SERVICE - Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1826" Reissued February 2013 This report is subject to renewal February 2015. www.icc-es.org I (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE installed in accordance with Section 4.5; and in Types I PROTECTION through IV construction when installed in accordance with Section:07 21 00—Thermal Insulation Section 4.6. REPORT HOLDER: The Classic Plus insulation are for use in Type V-B construction under the IBC and nonfire-resistance-rated ICYNENE, INC. construction under the IRC. 6747 CAMPOBELLO ROAD 3.0 DESCRIPTION MISSISSAUGA,ONTARIO L5N 2L7 3.1 General: CANADA (905) 363-4040 3.1.1 Classic and Classic Max: Icynene Classic and www.Icvnene.com Classic Max are low-density, open-cell, polyurethane foam plastic insulations and air barrier systems that are EVALUATION SUBJECT: 100 percent water-blown with an installed nominal density of 0.5 pcf (8 kg/m3) The insulations are two- ICYNENE CLASSIC, CLASSIC MAX, CLASSIC ECO AND component, spray-applied products The two components CLASSIC PLUS of the insulation are polymeric isocyanate (A-Component, also known as Base Seal®) and proprietary resin 1.0 EVALUATION SCOPE (B-Component, Classic or Classic Max Resin). When Compliance with the following codes: stored at temperatures between 50°F (10°C) and 100°F (38°C) the components have a shelf life of six months- ■ 2012 and 2009 International Building Code®(IBC) 3.1.2 Classic Eco: The Icynene Classic Eco foam plastic • 2012 and 2009 International Residential Code(IRC) insulation is two-component, low-density, open cell, spray- ■ 2012 and 2009 International Energy Conservation applied, foam 3 plastic with a nominal density of Code®(!ECC) 0 5 pcf (8 kg/m ) The polyurethane foam is produced by combining a polymeric isocyanate (A component) and • Other Codes(see Section 8.0) proprietary resin, Classic Eco(B component).When stored "Properties evaluated: at temperatures between 50°F (10°C) and 100°F (38°C), the components have a shelf life of six months • Surface burning characteristics 3.1.3 Classic Plus: The Icynene Classic Plus foam • Physical properties plastic insulation is two-component, low density, open cell, • Thermal performance(R-values) spray-applied, foam plastic with a nominal density of 0 7 pcf(11 kg/m3). The polyurethane foam is produced by • Attic and crawl space installation combining a polymeric isocyanate (A component) and • Fire resistance proprietary resin, Classic Plus (B component). When stored at temperatures between 50°F (10°C) and 100°F • Air permeability (38°C), the components have a shelf life of twelve months • Noncombustible construction 3.2 Surface Burning Characteristics: 2.0 USES 3.2.1 Classic and Classic Max: When tested in Icynene Classic, Classic Max, Classic Eco and Classic accordance with ASTM E84/UL 723, at a thickness of 6 inches (152 mm) and a nominal density of 0 5 pcf Plus are used to provide thermal insulation in buildings and (8 kg/m3), Icynene Classic and Classic Max have a flame to seal areas such as plumbing and conduit penetrations spread index of 25 or less and a smoke-developed index against air infiltration The insulations are for use in wall of 450 or less Thicknesses of up to 71/2 inches(190.5 mm) cavities and floor assemblies, and in attic and crawl space for wall cavities and 111/2 inches (292 mm) for ceiling installations as described in Section 4.4. cavities are recognized based on room corner fire testing The Classic, Classic Max and Classic Eco insulations are in accordance with NFPA 286, when covered with for use in Type V construction under the IBC and dwellings minimum 1/2-inch-thick (13 mm) gypsum board or an under the IRC; fire-resistance-rated construction when equivalent thermal barrier complying with the applicable *Revised December 2014 ICC-ES Evaluation Repons are not to be construed as representing aesthetics or any other aanbutes not specifically addressed,nor are they to be construed re as an endorsement of the subject ofrhe report or a recommendation for is use There is no warranty by ICC Evat a,on Serv,re,LLC express or implied,as to any finding or other mater in this report,or as so any product covered by the report Copyright®2014 Page 1 of 8 KXDate/Time 01110/2015 12:21 18019329469 P.008 To: Attn Dave Hattin Page 8 of 15 2015-01-10 17:1748(GMT) 18019329469 From: Douglas Kwazneski ESR-1826 ) Most Widely Accepted and Trusted Page 2 of 8 code. Greater thicknesses of insulation are recognized as The foam plastic insulation must not be used in electrical described in Section 4 4.1.2 1. outlet or junction boxes or in contact with rain or water, 3.22 Classic Eco: When tested in accordance with and must be protected from the weather during and ASTM E84/UL 723, at a thickness of 6 inches (152 mm) after application. Where the insulation is used as air- and a nominal density of 0.5 pcf(8 kg/m3), Icynene Classic impermeable insulation, such as in unvented attic spaces Eco has a flame spread index of 25 or less and a smoke- regulated by IRC Section R806, the insulation must be developed index of 450 or less- Greater than 6-inch installed at a minimum thicknesses noted in Section 3.4 (152 mm) thicknesses of insulation are recognized, based The insulation can be mst inti in one pass to the on the flame spread index of 25 or less, when the maximum thickness. Where multiple passes are required, insulation is covered with minimum Y°-inch-thick (13 mm) the cure time between passes is negligible gypsum wallboard or equivalent thermal barrier complying 4.2.2 Classic and Classic Max: The insulation must be with the applicable code used in areas where the maximum service temperature is 3.23 Classic Plus: When tested in accordance with no greater than 180°F (82°C). The insulation must be ASTM E84/UL 723, at a thickness of 4 inches (152 mm) applied when the temperature is at or above 14°F (-10°C) and a nominal density of 0 7 pcf (11 kg/m3), Icynene and be protected from the weather during and after Classic Plus has a flame spread index of 25 or less and a application. smoke-developed index of 450 or less Greater than 4.2.3 Classic Eco: The insulation may be used in areas 4-inch (102 mm) thicknesses of insulation are recognized, where the maximum service temperature is no greater than based on the flame spread index of 25 or less, when the 180°F (82°C) The insulation must be applied when the insulation is covered with minimum Winch-thick (13 mm) temperatures at or above 14°F (-10°C)and be protected gypsum wallboard or equivalent thermal barrier complying from the weather during and after application with the applicable code 4.2.4 Classic Plus: The insulation may be used in areas 3.3 Thermal Resistance: where the maximum service temperature is no greater than Icynene Classic, Classic Max, Classic Eco and Classic 180°F (82°C). The insulation must be applied when the Plus have thermal resistance (R-values) at a mean temperature is at or above 14°F (-10°C) and be protected temperature of 75°F(24°C)as shown in Table t from the weather during and after application. 3.4 Air Permeability: 4.3 Thermal Barrier: Icynene spray-applied foam 4.3.1 Classic and Classic Max: yplastic insulations are considered air-impermeable insulation in accordance with 4.3.1.1 Application with a Prescriptive Thermal 2012 IRC Sections R202 and R806 5 and 2009 IRC Barrier: Icynene Classic and Classic Max foam plastic Sections R202 and R806.4, at the following thicknesses. insulations must be separated from the interior of the • Classic and Classic Max: Minimum, 3 inches(76 mm) building by an approved thermal barrier, such as 1/2-inch based on testing in accordance with ASTM E2178 (12.7 mm) gypsum wallboard installed using mechanical fasteners in accordance with the applicable code, or an • Classic Eco: Minimum, 51/2 inches(140 mm)based on equivalent 15-minute thermal barrier complying with the testing in accordance with ASTM E283 applicable code When installation is within an attic or • Classic Plus: Minimum, 2 inches (51 mm) based on crawl space as described in Section 4 4, a thermal barrier testing in accordance with ASTM E2178- is not required between the foam plastic and the attic or crawl space, but s required between the foam plastic 3.5 Intumescent Coatings: insulation and the interior of the building. Thicknesses of 3.5.1 No Burn Plus XD: No Burn Plus XD intumescent up to 71/2 inches (1905 mm) for wall cavities and coating is a latex-based coating supplied in 1-gallon (4L) 113!2 inches (292 mm) for ceiling cavities are recognized and 5-gallon (19L) pails and 55-gallon (208 L) drums The based on room corner fire testing in accordance with NFPA coating material has a shelf life of 12 months when stored 286, when covered with minimum 1/2-inch-thick (13 mm) in factory-sealed containers at temperatures between 40°F gypsum board or equivalent thermal barrier complying with (4 4°C)and 90°F(32.2°C) the applicable code. 3.5.2 DC 315: DC 315 intumescent coating is a water- 4.3.1.2 Application without a Prescriptive Thermal based coating supplied in 5-gallon (19L) pails and Barrier or Ignition Barrier: The prescriptive 15-minute 55-gallon (208L) drums The coating material has a shelf thermal barrier or ignition barrier may be omitted when life of 24 months when stored in factory-sealed containers installation is in accordanc be with this section. The at temperatures between 41°F(5°C)and 95°F(35°C) insulation and coating may be spray-applied to the interior facing of walls, the underside or roof sheathing of roof 4.0 INSTALLATION rafters, and in crawl spaces, and may be left exposed as 4.1 General: an interior finish without a prescribed 15-minute thermal barrier or ignition bamer The thickness of the foam plastic The manufacturer's published installation instructions and applied to the underside of the roof sheathing must not this report must be strictly adhered to and a copy of these exceed 14 inches (356 mm). The thickness of the spray instructions and this evaluation report must be available on foam insulation applied to vertical wall surfaces must not the jobsite at all times during installation. exceed 6 inches (152 mm) The foam plastic must be 4.2 Application: covered on all surfaces with DC 315 coating at a minimum thickness of 20 wet mils[13 dry mils(0.33 mm)), applied at 4.2.1 General:Icynene Classic, Classic Max, Classic Eco a rate of 1.25 gallons (4.7 L) per 100 square feet(9.2 m2). and Classic Plus foam plastic insulations must be applied The coating must be applied over the insulation in on the jobsde using two-component, 1-to-1 ratio, spray accordance with the coating manufacturers instructions equipment specified by Icynene, Inc The foam plastic and this report. Surfaces to be coated must be dry, clean, must not be sprayed onto a substrate that is wet, or and free of dirt, loose debris and other substances that covered with frost or ice, loose scales, rust, oil or grease could interfere with adhesion of the coating. The coating is RX Date!Time 01110/2015 12:21 18019329469 P.009 To: Mtn- Dave 1-lattin Page 9 of 15 2015-01-10 1717.48(GMT) 18019329469 From: Douglas Kwazneski ESR-1826 [ Most Widely Accepted and Trusted Page 3 of 8 applied in one coat with low-pressure airless spray the roof sheathing must not exceed 14 inches (356 mm) equipment. The thickness of the spray foam insulation applied 4.3.2 Classic Eco: to vertical wall surfaces must not exceed 5-5 inches (140 mm) The insulation must be covered on all surfaces 4.3.2.1 Application with a Prescriptive Thermal with one of the coatings described in Section 35. The Barrier: Icynene Classic Eco polyurethane foam plastic coating must be applied over the insulation in accordance insulation must be separated from the interior of the with the coating manufacturer's instructions and this report building by an approved thermal barrier of '/cinch-thick Surfaces to be coated must be dry, clean, and free of dirt, (13 mm) gypsum wallboard or an equivalent 15-minute loose debris and other substances that could interfere with thermal barrier complying with, and installed in accordance adhesion of the coating_ The coating is applied in one coat with, 18C Section 26034 or IRC Section R316 4, as with low-pressure airless spray equipment The coating applicable. must be applied to a thickness as follows: 4.3.3 Classic Plus: ■ No Burn Plus XD at a minimum thickness of 6 wet mils 4.3.3.1 Application with a Prescriptive Thermal (0.15 mm) [4 dry mils (0 1 mm) dry film thickness], • Barrier: Icynene Classic Plus polyurethane foam plastic applied at a rate of 04 gallon (1.5 L) per 100 square insulation must be separated from the interior of the feet(9.2 m2). building by an approved thermal barrier of '/z-inch-thick • DC 315 at a minimum thickness of 4 wet mils (0.1 mm) (13 mm) gypsum wallboard or an equivalent 15-minute [3 dry mils], applied at a rate of 03 gallon (1.1 L) per thermal barrier complying with, and installed in accordance 100 square feet(9.2 m2). with, IBC Section 2603 4 or IRC Section R316.4, as The coatings must be applied when ambient and applicable 9 pP substrate temperature is at least 60°F (16°C) and no more 4.4 Attics and Crawl Spaces: than 95'F (35°C) All other surfaces(including glass) must 4.4.1 Classic and Classic Max: be protected against damage from the coating. The insulation may be installed in unvented attics when the 4.4.1.1 Application with a Prescriptive Ignition Barrier: foam plastic is applied at a minimum thickness of When Icynene Classic and Classic Max foam plastic 35 inches (89 mm) as described in this section in insulations are installed within attics where entry is made accordance with 2012 IRC Section R806.5 or 2009 IRC only for service of utilities, an ignition barrier must be Section R806.4, as applicable installed in accordance with IBC Section 2603.4 1.6 and IRC Sections R316 5 3 and R316 5.4, as applicable The 4.4.1.22 Attics—Classic Max: When Classic Max is ignition barrier must be consistent with the requirements applied in unvented attics conforming to 2012 IRC Section for the type of construction required by the applicable code R806.5 or 2009 IRC Section R806.4, the insulation may be and must be installed in a manner so that the foam plastic applied to the underside of roof sheathing and/or rafters to insulation is not exposed. The Classic or Classic Max a minimum thickness of 3 /2 inches (90 mm) and may be insulation may be installed in unvented attics when the applied to vertical wall surfaces to a minimum thickness of foam plastic is applied at a minimum thickness of 3 inches 3!z inches (90 mm) Maximum thickness on the underside (76 mm) in accordance with 2012 IRC Section R806.5 or of roof sheathing or on vertical wall surfaces is 20 inches 2009 IRC Section R806.4, as applicable (508 mm) The insulation may be left exposed to the attic without a prescriptive ignition barrier or an intumescent 4.4.1.2 Application without a Prescriptive Ignition coating Barrier. Where Icynene Classic and Classic Max foam plastic insulations are installed in an attic or crawl space The attic must have attic access complying with IRC without a prescriptive ignition barrier, in accordance with Section R807, horizontally placed in the floor, and th opening Sections 4.4 1 2.1, 4 4 1 2 2, 4.4 1 2.3 and 4 4 1 2 4, the outward toward the living space. Items penetrating the roof following conditions apply deck or walls, such as skylight wells and vents, must be covered with a minimum of 31/2 inches (90 mm) of the 1. Entry to the attic or crawl space is only for service of Classic Max insulation. utilities and no storage is permitted 4.4.123 Crawl Spaces: In crawl spaces, Icynene 2. There are no interconnected attic, crawl space or Classic and Classic Max insulations may be spray-applied basement areas to vertical walls and the underside of floors,as described in 3. Air in the attic or crawl space is not circulated to other this section The thickness of the foam plastic applied to parts of the building the underside of the floors must not exceed 14 inches (356 mm) The thickness of the spray foam plastic 4 Combustion air is provided in accordance with IMC insulation applied to vertical wall surfaces must not exceed Section 701. 31/2 inches (88.9 mm). The foam plastic does not require 5. Attic ventilation is provided when required by IBC an ignition barrier or a coating. Section 1203 2 or IRC Section R806, except when 4.4.1.2.4 Use on Attic Floors:When used on attic floors, air-impermeable insulation is permitted in unvented Icynene Classic and Classic Max foam plastic insulations attics in accordance with 2012 IRC Section R806.5 or may be installed at a maximum thickness of 111/2 inches 2009 IRC Section R806.4, as applicable (292 mm)between Joists in attic floors. The insulation must 6 Under-floor(crawl space)ventilation is provided when be separated from the interior of the building by an required by IBC Section 1203 3 or IRC Section approved thermal barrier. The coatings specified in Section R408.1, as applicable. 4.4.1.2.1 and the ignition barrier in accordance with IBC Section 2603.4.1 6 and IRC Section R316.5.3, may be 4.4.1.2A Attics — Classic and Classic Max: In attics, omitted. Icynene Classic and Classic Max foam plastic insulations 4.4.2 Classic Eco: may be spray-applied to the underside of the roof sheathing and/or rafters, as described in this section The 4.4.2.1 Application with a Prescriptive Ignition Barrier: thickness of the foam plastic applied to the underside of When Icynene Classic Eco is installed within attics or crawl RX Date/Time 01/10/2015 12:21 18019329469 P.010 To Attn. Dave Hattin Page 10 of 15 2015-01-10 17:17.48(GMT) 18019329469 From: Douglas Kwazneski ESR-1826 [ Most Widely Accepted and Trusted Page 4 of 8 spaces where entry is made only for service of utilities, an this section, in accordance with 2012 IRC Section R806 5 ignition barrier must be installed in accordance with IBC or 2009 IRC Section R806.4,as applicable. Section 2603 4 1 6 and IRC Sections R316.5.3 and 4.4.22.2 Crawl Spaces: In crawl spaces, Icynene R316 5.4, as applicable The ignition barrier must be Classic Eco insulation may be spray-applied to vertical consistent with the requirements for the type of walls and the underside of floors, as described in this construction required by the applicable code and must be section The thickness of the foam plastic applied to the installed in a manner so that the foam plastic insulation is underside of the floors must not exceed 14 inches not exposed Icynene Classic Eco may be installed in (356 mm). The thickness of the spray foam plastic unvented attics when the foam plastic is applied at a insulation applied to vertical wall surfaces must not exceed minimum thickness of 5.5 inches (140 mm) in accordance 31/2 inches (88.9 mm) The foam plastic does not require with 2012 IRC Section R806 5 or 2009 IRC Section an ignition barrier or a coating_ R806.4,as applicable 4.4.2.2 Application without a Prescriptive Ignition 4.4.2.2.3 Use on Attic Floors: Icynene Classic Eco Barrier:Where Icynene Classic Eco insulation is installed insulation may be installed at a maximum thickness of 51/2 in accordance with Sections 4 4 2.2 1, 4.4.2.2.2 and inches (152 mm) between joists in attic floors when 4.422.3,the following conditions apply: covered with one of the coatings applied as described in Section 4 4 2.2 1. The insulation must be separated from 1. Entry to the attic or crawl space is to service utilities, the interior of the building by an approved thermal barrier. and no storage is permitted. 4.4.3 Classic Plus: 2. There are no interconnected attic or crawl space 4.4.3.1 Application with a Prescriptive Ignition Barrier: areas When Icynene Classic Plus is installed up to a maximum 3 Air in the attic or crawl space is not circulated to other thickness of 4 inches (102 mm) within attics or crawl parts of the building. spaces where entry is made only for service of utilities, an 4 Combustion air is provided in accordance with IMC ignition barrier must be installed in accordance with IBC Section 701 Section 2603 4.1 6 and IRC Sections R316 5.3 and R316.5.4, as applicable. The ignition barrier must be 5. Attic ventilation is provided when required by IBC consistent with the requirements for the type of Section 1203.2 or IRC Section R806, except when construction required by the applicable code and must be air-impermeable insulation is permitted in unvented installed in a manner so that the foam plastic insulation is attics in accordance with 2012 IRC Section R806.5 or not exposed. Icynene Classic Plus may be installed in 2009 IRC Section R806.4, as applicable. unvented attics when the foam plastic is applied at a 6 Under-floor(crawl space)ventilation is provided when minimum thickness of 2 inches (51 mm) in accordance with 2012 IRC Sect required by IBC Section 1203 3 or IRC Section Section R806 5 or 2009 IRC Section R408.1, as applicable. R806.4,as applicable 4.4.2.2.1 Attics and Crawl Spaces: In attics and crawl 4.4.3.2 Application without a Prescriptive Ignition spaces, Icynene Classic Eco insulation may be spray- Barrier: Where Icynene Classic Plus insulation is installed applied to the underside of the roof sheathing and/or in accordance with Sections 44.3.21, 44.3.2.2, and rafters,the underside of wood floors, and vertical surfaces, 4.4.3.2 3, the following conditions apply: as described in this section The thickness of the foam 1. Entry to the attic or crawl space is to service utilities, plastic applied to the underside of the top of the space and no storage is permitted. must not exceed 13'12 inches (343 mm). The thickness of 2 There are no interconnected attic or crawl space the spray foam plastic insulation applied to vertical wall P surfaces must not exceed 51h inches (140 mm) The foam areas plastic must be covered on all surfaces with one of the 3. Air in the attic or crawl space is not circulated to other coatings described in Section 3.5. The coating must be parts of the building applied over the Icynene Classic Eco insulation in 4 Combustion air is provided in accordance with IMC accordance with the coating manufacturer's instructions Section 701. and this report. Surfaces to be coated must be dry, clean, and free of dirt, loose debris and other substances that 5. Attic ventilation is provided when required by IBC could interfere with adhesion of the coating. The coating is Section 1203 2 or IRC Section R806, except when applied in one coat with low-pressure airless spray air-impermeable insulation is permitted in unvented equipment. The coating must be applied to a thickness as attics in accordance with 2012 IRC Section R806.5 or follows. 2009 IRC Section R806.4, as applicable • No Burn Plus XD at a minimum thickness of 10 wet mils 6. Under-floor(crawl space)ventilation is provided when (0.3 mm) [6 dry mils (0.2 mm)], applied at a rate of required by IBC Section 1203.3 or IRC Section 0.63 gallon(2.4 L)per 100 square feet(9 2 m2) R408.1,as applicable. • DC 315 at a minimum thickness of 8 wet mils (0 2 mm) 4.4.3.2.1 Attics: In attics, Icynene Classic Plus insulation [6 dry mils (0.2 mm)i, applied at a rate of 0 5 gallon may be spray-applied to the underside of the roof (1.9 L)per 100 square feet(9 2 m2) sheathing and/or rafters,the underside of wood floors, and The coating must be applied when ambient and vertical surfaces, as described in this section. The substrate temperature is at least 60°F (16°C) and no more thickness of the foam plastic applied to the underside of than 95°F (35°C). All other surfaces (including glass) must the top of the space must not exceed 14 inches (356 mm). be protected against damage from the coating. The thickness of the spray foam plastic insulation applied to vertical wall surfaces must not exceed 8 inches Icynene Classic Eco insulation may be installed in (203 mm). The foam plastic insulation must be covered on unvented attics when the foam plastic is applied at a all exposed surfaces with DC315 intumescent coating at a minimum thickness of 51/2 inches(140 mm)as described in minimum thickness of 4 wet mils (0.1 mm) [3 dry mils RX Date/Time 01110/2015 12:21 18019329469 P.011 To Attn Dave Hattin Page 11 of 15 2015-01-10 17 17.48(GMT) 18019329469 From Douglas Kwazneski ESR-1826 I Most Widely Accepted and Trusted Page 5 of 8 (0.08 mm)j, applied at a rate of 0.25 gallon (0.95 L) per Axial loads applied to the wall assembly must be limited 100 square feet (9-2 m2) The coating must be applied to the least of the following over the Icynene Classic Plus insulation in accordance with 1,805 pounds(8029 N)per stud the coating manufacturer's instructions and this report Surfaces to be coated must be dry, clean, and free of dirt, • Design stress of 0 78 F'c loose debris and other substances that could interfere with • Design stress of 0 78 Pc at a maximum Intl of 33 adhesion of the coating. The coating is applied in one coat with low-pressure airless spray equipment. 4.5.1.3 Assemblyh 3 ( loor/Ceiling): Minimum nominally The coating must be applied when ambient and 2-by-10 [11by 9/4 inches (38 mm by 235 mm)] Douglas substrate temperature is at least 60°F (16°C)and no more fir, No. 2 grade wood joists spaced 24 inches (610 mm) on than 95°F (35°C). All other surfaces (including glass) must center, with minimum 1-by-3 [ !a by 21/2 inches (19 1 by be protected against damage from the coating. 64 mm)] spruce bridging at mid-span Floor decking must be minimum /rinch-thick (12 7 mm) exterior grade Icynene Classic Plus insulation may be installed in plywood installed perpendicular to joists and fastened with unvented attics when the foam plastic is applied at a 2-inch-long (51 mm) ring shank nails 6 inches(152 mm)on minimum thickness of 2 inches (51 mm) as described in center at the joints and 12 inches (305 mm) on center at this section, in accordance with 2012 IRC Section R806 5 the intermediate joists Plywood joints must occur over or 2009 IRC Section R806.4, as applicable joists. Icynene Classic or Classic Max insulation must be 44.3.2.2 Crawl Spaces: In crawl spaces, Icynene applied to the underside of the plywood deck between the Classic Plus insulation may be spray-applied to vertical joists to a Sdepth of 5 inches (127 mm). Two layers of walls and the underside of floors, as described in this minimum /winch-thick (15 9 mm), Type X gypsum section. The thickness of the foam plastic applied to the wallboard must be attached perpendicular to the joists on underside of the floors must not exceed 14 inches the ceiling side of the assembly_ The first layer must be (356 mm). The thickness of the spray foam plastic attached with 11/4-inch-long (32 mm), Type W drywall insulation applied to vertical wall surfaces must not exceed screws, spaced 24 inches (610 mm) on center. The 8 inches (203 mm). The insulation must be covered with second layer must be applied perpendicular to the joists, DC-315 coating is described in Section 4 4.3.2.1 offset 24 inches(610 mm)from the base layer.The second layer must be attached with 2-inch-long (51 mm), Type S 4.4.3.2.3 Use on Attic Floors: Icynene Classic Plus drywall screws spaced 12 inches (305 mm) on center insulation may be installed at a maximum thickness of Additional fasteners must be installed along the butt joints 13 inches (330 mm) between joists in attic floors The of the second layer, securing the two layers together. insulation must be separated from the interior of the These fasteners must be 1'/cinch-long (38 mm), Type G building by an approved thermal barrier. The insulation drywall screws placed 2 inches (51 mm) back from each does not require an ignition barrier or a coating end of the butt joint and spaced 12 inches (305 mm) on 4.5 One-hour Fire-resistance-rated Assemblies: center. The wallboard joints on the exposed side must be treated with paper tape embedded in joint compound and 4.5.1 Classic and Classic Max: topped with an added coat of compound, and the fastener 4.5.1.1 Assembly 1 (Limited Load-bearing Wood Stud heads must be coated with joint compound in accordance Wall): Minimum nominally 2-by-4 [11/7 by 31/2 inches with ASTM C840 or GA-216. (38 mm by 89 mm)] southern pine(G = 0 55), No. 2 grade 4.5.1.4 Assembly 4(Non-loadbearing Steel Stud Wall): studs spaced 16 inches (406 mm) on center with a base Nominally 6-inch-deep (152.4 mm), No. 18 gage, layer of /2-inch-thick (12.7 mm) wood fiber sound board galvanized steel studs spaced 16 inches (406.4 mm) on installed horizontally on each face with vertical joints center, are friction-fit into No 18 gage galvanized steel located over the studs, attached with 6d box nails, 2 inches floor and ceiling track with a layer of 5/s-inch-thick (51 mm) long and spaced 24 inches (610 mm) on center 15 9 mm along the studs, and a second layer of 5/8-inch-thick side Yon X gypsum board applied lied to the interior side with the long edge parallel to steel studs and secured (15.9 mm) Type X gypsum wallboard installed vertically on using No 6, 11/4-inch-long (31.7 mm), self- drilling drywall each face, attached with 8d box nails, 2112 inches (64 mm) screws spaced 8 inches (203 mm) on center around the long and spaced 7 inches (178 mm) on center along the perimeter and 12 inches (305 mm) on center in the field. studs. The stud cavity contains Icynene Classic or Classic The gypsum board joints must be treated with vinyl or Max insulation nominally 2 inches(51 mm)thick. casein, dry or premtxed joint compound applied in two Axial loads applied to the wall assembly must be limited coats to cover all exposed screw heads and gypsum board to the least of the following: butt joints, and a minimum 2-inch-wide (51 mm) paper, • 1,805 pounds(8029 N)per stud. plastic, or fiberglass tape embedded in the first layer of compound over butt joints of the gypsum board. The stud • Design stress of 0.78 F'c. cavity is filled with Icynene Classic or Classic Max insulation up to 6 inches (152 mm) thick DensGlasse • Design stress of 0 78 Pc at a maximum kid of 33. Exterior Sheathing, 1/2 inch (12.7 mm) thick, is installed 4.5.1.2 Assembly 2 (Limited Load-bearing Wood Stud parallel to steel studs with vertical joints offset a minimum Wall): Minimum nominally 2-by-4 [11/2 by 31/2 inches of 16 inches (406 mm) from the vertical joints of the (38 mm by 89 mm)]southern pine(G = 0.55), No. 2 grade gypsum board and the horizontal joints offset a minimum of studs spaced 16 inches (406 mm) on center with two 24 inches (610 mm) from the horizontal joints of the layers of '/cinch-thick (12 7 mm) Type X gypsum gypsum board. The sheathing is attached using No. 6, wallboard installed vertically with joints staggered on each 1 /4-inch-long (31.7 mm), self-drilling drywall screws face, attached with 8d box nails, 21/2 inches (64 mm) long spaced 8 inches (203 mm) on center around the perimeter and spaced 7 inches (178 mm) on center along the studs and in the field. Hohmann & Barnard DW-10 brick ties, for the face layer and 6d cement coated box nails, 2 inches 6 inches (152 mm) long by 1'/2-inches (38 mm) wide, are (51 mm) long and spaced 24 inches (610 mm) on center spaced 16 inches(406.4 mm) on center vertically on each along the studs The stud cavity contains Icynene Classic steel stud, and secured, using two 15/s-inch-long(41 3 mm) or Classic Max insulation nominally 2 inches(51 mm)thick_ self-drilling screws, through 4-inch(102 mm)red clay brick KAUatenlme 01110/2015 1221 18019329469 P.012 To:Attn: Dave Hattin Page 12 of 15 2015-01-10 17 17 48(GMT) 18019329469 From. Douglas Kwazneski ESR-1826 [ Most Widely Accepted and Trusted Page 6 of 8 13112 inches (88.9 mm) by 21/4 inches (57.1 mm) by 4.6.2 Exterior Face: Nominally 6-inch-deep (152 mm), 73/4 inches (197 mm)1 laid in a running bond pattern with No. 18 gage, galvanized steel studs spaced 16 inches Type S mortar, leaving a nominally 1-inch (25.4 mm) air (406 mm) on center, are fastened to No. 18 gage, gap between the bnck and the exterior sheathing. galvanized steel floor and ceiling track using No. 8, /s-inch-long (22 2 mm),eself-tapping pan head framing Optional: It is permitted to add code-complying, expanded polystyrene (EPS), extruded polystyrene (XPS), screws. GP DensGlass Exterior Sheathing, 1/2 inch foil-faced, rigid polyurethane board stock or polyurethane (12 7 mm) thick, installed over the exterior side of steel studs with the long end perpendicular to the steel studs, spray foam on the exterior of the wall (between the i ® usinglNa 6, ee S, p /ced 8 (3 1_7 mm)(2long, self-tapping DensGlass sheathed wall and the brick), while bugle head screws spaced 8 inches (203 mm) on center maintaining the 1-inch (25.4 mm) air space The length of around the perimeter and in the field The stud cavity is the brick ties must be increased to account for the filled with Icynene Classic, Classic Max or Classic Eco thickness of the insulation. insulation to a nominal thickness of 6 inches(152 mm). 4.5.2 Classic Eco (Non-loadbearing Steel Stud Wall): 4.6.3 Interior Face: Type X gypsum board, 5/9 inches Nominally 6-inch-deep (152 mm) deep, No. 18 gage, (15 9 mm) thick, is installed with the long dimension galvanized steel studs spaced 16 inches (406 mm) on perpendicular to steel studs with No. 6, Type S, 11/4 inch- center, are friction-fit into No 18 gage galvanized steel long (31 7 mm), self-tapping, bugle head screws spaced floor and ceiling track with a layer of /s-inch-thick 8 inches (203 mm) on center around the perimeter and in (159 mm), Type X gypsum board installed to the interior the field. The gypsum board joints must be treated with side with the long edge parallel to steel studs and secured vinyl or casein, dry or premed joint compound applied in using No 6, 11/4-inch-long (31.7 mm), self-drilling drywall two coats to cover all exposed screw heads and gypsum screws spaced 8 inches (203 mm) on center around the board butt joints, and a minimum 2-inch-wide (51 mm) perimeter and 12 inches (305 mm) on center in the field. paper, plastic, or fiberglass tape embedded in the first The gypsum board joints must be treated with vinyl or layer of compound over butt joints of the gypsum board casein, dry or premored joint compound applied in two coats to cover all exposed screw heads and gypsum board 4.6.4 Exterior Wall Covering: Details of the exterior wall butt joints, with a minimum 2-inch-wide (51 mm) paper, covering must be provided to the code official by the report plastic, or fiberglass tape embedded in the first layer of holder, designer or specifier, with an engineering analysis compound over butt joints of the gypsum board. The stud demonstrating that(1) the exterior wall covering conforms cavity is filled with Icynene Classic Eco insulation up to to ASTM E136 and (2)the addition of the wall covering to 6 inches (152 mm) thick. DensGlass Exterior Sheathing, the assembly described in this section does not negatively 1/2 inch (12.7 mm) thick, is installed parallel to steel studs affect conformance of the assembly with the requirements with vertical joints offset a minimum of 16 inches(406 mm) of IBC Section 2603-5. from the vertical joints of the gypsum board and the 5.0 CONDITIONS OF USE horizontal joints offset a minimum of 24 inches (610 mm) From the horizontal joints of the gypsum board. The The Icynene Classic, Classic Max,Classic Eco and Classic Plus spray-applied polyurethane foam plastic insulations sheathing is attached using No. 6, 11/4-inch-long (31.7 mm), self-drilling drywall screws spaced 8 inches described in this report comply with, or are suitable (203 mm) on center around the perimeter and in the field alternatives to what is specified in, those codes listed in Hohmann & Barnard OW-10 brick ties, 6 inches (152 mm) Section 1.0 of this report, subject to the following long by 11/2 inches (38 mm) wide and spaced 16 inches conditions: (406 mm) on center vertically on each steel stud, are 5.1 This evaluation report and the manufacturer's secured, using two 15/8-inch-long (41 3 mm) self-drilling published installation instructions, when required by screws, through 4-inch(102 mm)red clay brick[31/2 inches the code official, must be submitted at the time of (88.9 mm) by 21/4 inches (57.1 mm) by 73/4 inches permit application (197 mm)) laid in a running bond pattern with Type S 5.2 The insulation must be installed in accordance with mortar A nominally 1-inch (25 4 mm) air gap is left the manufacturer's published installation instructions, between the brick and the exterior sheathing. this evaluation report and the applicable code. If there Optional. It is permitted to add code-complying EPS, is a conflict between the installation instructions and XPS, foil-faced, rigid polyurethane board stock or this report,this report governs. polyurethane spray foam on the exterior of the wall 5.3 The insulation must be separated from the interior of (between the DensGlass sheathed wall and the brick), the building by an approved 15-minute thermal while maintaining the 1-inch (25.4 mm) air space. The barrier, except as noted in this report. length of the brick ties must be increased to account for the thickness of the insulation 5.4 Since the performance of Classic Max, when installed in unvented attics without a code-prescribed ignition 4.6 Exterior Walls in Type I, lit III and IV Construction: barrier or an intumescent coating, is based on fire 4.6.1 General:When used on exterior walls of Types I, II, performance of an unvented attic, the installation III or IV construction, the assembly must comply with IBC must be approved by the code official as conforming Section 2603.5 and this section, and the Classic, Classic with the provisions of Section 44.1.2.2 and Max and Classic Eco insulations must be installed at a Conditions 1 to 5 of Section 4 4.1.2 maximum thickness of 6 inches (152 mm) The potential 5.5 When Classic Max insulation is installed under heat of Icynene insulations tested in accordance with Section 4.4 1.2 2 of this report, a certificate must be NFPA 259 is as follows: placed in the attic stating that the foam plastic • Classic and Classic Max: 494 Btu/D[2(5 6 MJ/m2) per insulation has been installed in accordance with inch of thickness Conditions 1 to 5 of Section 4.4 1.2 and the terms of Section 4.4.1 2.2 of ESR-1826; any alterations to the • Classic Eco: 168 Btu/ft2 (1.9 MJ/m2) per inch of attic or insulation must be consistent with those thickness requirements RxDate!Time 0111012015 12:21 18019329469 P.013 To: Attn: Dave Hattin Page 13 of 15 2015-01-10 17.17 48(GMT) 18019329469 From Douglas Kwazneski ESR-1826 I Most Widely Accepted and Trusted Page 7 of 8 5.6 The insulation must not exceed the thicknesses and 7.0 IDENTIFICATION densities noted in this report All packages and containers of Classic, Classic Max, 5.7 The insulation must be protected from the weather Classic Eco and Classic Plus insulations must be labeled during and after application. with the Icynene, Inc, name and address; the product 5.8 The insulation must be applied by licensed dealers name; component designation (A or B); the flame spread and installers certified by Icynene, Inc index and the smoke-developed index; the shelf life expiration date; the name of the inspection body (ICC-ES); 5.9 Use of the insulation in areas where the probability of and the evaluation report number(ESR-1826). termite infestation is "very heavy" must be in Intumescent coatings are identified with the accordance with IRC Section R318.4 or IBC Section 2603 8,as applicable manufacturer's name and address, the product trade name and use instructions. 5.10 Jobsite certification and labeling of the insulation must 8.0 OTHER CODES comply with IRC Sections N1101.4 and N1101 4.1 and IECC. Sections 30311 and 3031 2, as 8.1 Scope: applicable In addition to the codes referenced in Section 1 0, the 5.11 A vapor retarder must be installed in accordance with products recognized in this report were evaluated for the applicable code compliance with the requirements of the following codes: 5.12 Icynene Classic, Classic Max, Classic Eco and • 2006 International Building Codes(2006 IBC) Classic Plus foam plastic insulations are • 2006 International Residential Cale(2006 IRC) manufactured in Mississauga, Ontario,Canada, under a quality control program with inspections by ICC-ES. • 2006 International Energy Conservation Codes (2006 6.0 EVIDENCE SUBMITTED IECC) 6.1 Data in accordance with the ICC-ES Acceptance 8.2 Uses: Criteria for Spray-applied Foam Plastic Insulation The products comply with the above-mentioned codes as (AC377), dated November 2012 (editorially corrected described in Sections 20 to 7.0 of this report, with the April 2013). revisions noted below 6.2 Reports of tests in accordance with AC377 Appends • Application with a Prescriptive Ignition Barrier. See X [Classic and Classic Max (Section 4.4.12.1), Sections 4.4 1.1 (Classic and Classic Max) 4.4 2.1 Classic Eco (Section 4 4.2 2 1) and Classic Plus (Classic Eco) and 4.4 3 1 (Classic Plus), except attics (Sections 4 4.3.2.1 and 4 4.3.2.3)] and Appendix C must be vented in accordance with 2006 IBC Section [Classic and Classic Max (Section 4 4 1.2.3), and 1203 2, and crawl space ventilation must be in Classic Eco(Section 4.4 2 2 2)]. accordance with 2006 IBC Section 1203.3, as 6.3 Test reports on air leakage rate in accordance with applicable. Additionally, an Ignition barrier must be ASTM E283(Classic Eco). installed in accordance with 2006 IRC Section R314 5 3 or R314 5 4, as applicable 6.4 Test report on air leakage rate in accordance with • Application without a Prescriptive Ignition Barrier. ASTM E2178 (Classic, Classic Max and Classic See Sections 4.4 1.2 (Classic and Classic Max), 4.4.2.2 Plus) (Classic Eco) and 4.4.3.2 (Classic Plus), except attics 6.5 Reports of room corner fire testing in accordance with must be vented in accordance with 2006 IBC Section NFPA 286 (Classic, Classic Max, Classic Eco, and 1203 2 or 2006 IRC Section R806, and crawl space Classic Plus). ventilation must be in accordance with 2006 IBC Section 6.6 Test reports in accordance with ASTM E119(Classic, 1203 3 or 2006 IRC Section R408, as applicable. Classic Max and Classic Eco). • Jobsite Certification and Labeling:See Section 5 10, 6.7 Test report in accordance with NFPA 285, and related except Jobsite certification and labeling must comply ` engineering analysis (Classic, Classic Max and app 2006 IECC Sections 102.1.1 and 102.1.11, as Classic Eco). applicable • Protection Against Termites: See Section 5.9, except 6.8 Reports of tests in accordance with NFPA 259 use of the insulation in areas where the probability of (Classic, Classic Max and Classic Eco). termite infestation is "very heavy" must be in 6.9 Reports of fire tests in accordance with ASTM E970 accordance with 2006 IRC Section R320.5. (Classic, Classic Max and Classic Plus). 6.10 For Classic Max, an engineering evaluation, including full-scale fire testing, small-scale testing and fire modeling(Section 4.4 1.2.2) RX DatelTime 01/10/2015 12:21 18019329469 P.014 To:Attn: Dave Hattin Page 14 of 15 2015-01-10 17.17 48(GMT) 18019329469 From Douglas Kwazneski ESR-1826 I Most Widely Accepted and Trusted Page 8 of 8 TABLE 1—THERMAL RESISTANCE(R-VALUES) R-VALUE(°F•ft'•h/Btu) THICKNESS Classic and Classic Max Classic Eco Classic Plus (inches) 1 37 37 40 2 74 7.4 8 0 3 11 11 12 35 13 13 14 4 14 14 16 5 18 18 20 5.5 20 20 22 6 22 22 24 7 25 25 28 7.5 27 27 30 8 29 29 32 9 32 32 36 9.5 34 • 34 38 10 36 36 40 11 5 41 41 42 13 5 — 49 54 14 50 50 56 For SI: 1 inch=25 4 mm, 1°F-ft2-h/Btu=0-176 110°K-m21W. 1R-values are calculated based on tested K values at 1-and 3 5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number f�) /o -i a Inspection Form n Town of Queensbury Fire Marshal 0 Periodic Inspection Date: i-9-I5 Time:/v 742 Bay Road,Queensbury NY 12804irye-Inspection 518 761 8206/518 761 8205 SCO Inspection Permit#: 1 / --3 Lt ' Fir arshals Representative Palmer Business Name: �uor ( e�d� Location: 3 1 O . i 6 a Rd GK Stillman Contact: V hnk ate G CI- 6-)A1 to t7 ataAay a Type of Inspection N/A Yes_ No EXITS. Exit Access FC 1014&FC1029 / NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 ..---Ca., Si n:Normal FC 1011 &FC1029 ,q 2 - r Sinn backu• FC 1011.5.3&FC1029.7.5 �/G /(,,,i . /6 7--- ,to AISLES: V ��,,'�.,�� Main Aisle Width FC 1024/1025&FC1029.11 �HLQ' V Aa\ Secondary Aisle W dth FC 1025&FC1029.11S 3 LI Ss FIRE EXTINGUISHER: Hung FC 906 //(111 Inspection of extinguisher FC 906 P&L in-qtsj EVAC Plan FC 404.2 TRUSS ID SIGNAGE FC 505.3 IMA__ /,, EMERGENCY LIGHTING: __- l/0 ii\li& e) i Trarc I ..Interior FC 1006.3&FC1029.8 _—_� l../�'� 'fvs!/ !J 1'((Lp'� Exterior FC 1006.3 /Lr / Clearance to Electrical FC 605.3 IWO Electric Wiring Enclosed/LabeledFC 605.3.1 Combustibles in Equipment Rooms FC315.2.3 197— nejGAWe / F.D.Signage- FC 510 No Smoking Signs FC 310.3 Stora se FC315.2 an Compressed Gas FC 3003I/.��1.R��'flo /d Vehicle Impact Protection FC 312.1 ../.......° 1L1ilIi5— /A1 ad Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 / Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 Vacant Buildings FC 311 REINSPECTION DUE APPROXIMATELY Emergency Disconnect FC 2203.2 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 f//.5 Operating Permit, if required will be issued after Completion of Inspection f. Town of Queensbury Building&Code Enforcement I ri lb/a, ' Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: S(�'i� t r l_ej Inspected on: /"9 "/5 Location: -a I rj L) s `x t Rd Arrive: a.m.!p.m. Permit No.: ,/ 7 3 Ca q Inspector's Initials: rEa cia ya COMMENTS Y z N NA Chimney/"B"Vent/Direct Vent Location �� Plumbing Vent Through Roof 6"/Roof Complete / Exterior Finish/Grade Complete 6"in 10'or Equivalent r/ � Interior/Exterior Guardrails 42 inch Platform/Decks ✓ Interior/Exterior Balusters 4 inch Spacing Plafform/Decks / Stair Handrail 34 inch–38 inch/Step Risers 7"!Treads 11" ✓ n �/` ` / Vestibules For Exit doors>3000 sq.ft. / /Vey .1;jjak-- All Doors 36 inch w/Lever Handles/Panic Hardware, if required ✓ CF-! ��� 1�� , Exits At Grade Or Platform 36"(w)x 44"(0/Canopy or Equiv. a/ / Gas Valve Shut-off Exposed&Regulator(18")Above Grade ✓� i ecsl Floor Bathroom Watertight/Other Floors Okay J Relief Valve, Heat Trap!Water Temperature 110 Degrees Maximum pp Boiler!Furnace Enclosure 1 hour or Fire Extinguishing System ✓ (le. s/I 7 'tam Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers / Gas Furnace Shut Off Within 30 ft.or Within Line Of Site ✓ Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '%doors > 10%> 1000 sq.ft. v../ +r/ %Hour Corridor Doors&Closers ✓ Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame I/ Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" / Smoke Vents Or Fan, if required ,/ / Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors / l/ / Handicapped Bath/Parking Lot Signage r/ rsi�� Ap`�.jtx� ��•i Public Toilet Room Handicapped Accessible l/ J/ v Handicapped Service Counters,34 inch,Checkout 36 inch / / �/J Handicapped Ramp/Handrails Continuous/12 inch Beyond [Both sides] y i/ �tro!1«'� PfEoi Kt' Active Listening System and Signage Assembly Space / / .5/51,4)a— Final Electrical/Flex Gas Piping Bonded t/ Site Plan/Variance required fre Final Survey, New Structure!Flood Plain certification,if req. ✓/ yrlA_,;r/ .I As-built Septic System Layout Required or On File Y / Building Number or Tenant Address on Building or Driveway 4" ✓ / Water Fountain or Cooler ✓ Building Access All Sides by 20'/Drivable Surface 20'wide ✓/ L� /A / Special Inspections/Engineer ori ' t Approval /✓ ht/� t.r2/ �/Je ! /'>1 Okay To Issue Temporary ermanent C/ ✓ U Okay To Issue C/C Commercial Final Inspection_11 2712 Septic Inspection Report Office No. (518) 761-8256 Date Ins on requ - Queensbury Building &Code Enforcement Arrive: 3 II) a •.rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: / NAME: •`�C>^111 F R1,-.F 11J IT NO.: I \ —3(r11-1 LOCATION: 31 Q fl 1)(2'10 R\) SPECT ON: ! t —7 kr 19 RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Munidpal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50'+/- _Y_N_N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Reid/ Pit Opening Sealed: _Y_N End Cap _Y N Inlet/Outiet Pipes& Baffles _Y N Manholes 12"or less below grade _Y_N [provide extension collar if Yes] Y N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y_N Engineer Report and As-Built Y_ N ETU Maintenance Contract Y_ N provided Location of System on Property: Front ear Left Side Right Side Middle Front Middle Rear S st m Use S s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\wilding Codes Founs\Irspection Forms\Septic Inspection Report_03 2910.doc IIn of Queensbury Building & Code Enforcement Ll_ K/ Office No. (518) 761-8256 "- ueS oCC Septic Inspection Report Inspection request received: Name: Schu&c I .t In Inspected on: ' oA_air Location: c3 b 13Rd [� A Arrive: z" 46�Sa.m Ip.m. Permit No.: / —3 to 71 Inspector's Initials: �a omments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50'+/- _Y_N_N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed Y_N End Cap _Y N/ Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade _[jN [provide extension collar if Yes] Y N ��IS J`� t-A \� Location I Separations Xc� Foundation to tank ft. Foundation to absorption ft. Separation of Pits /ft. Conforms as per Plot Plan _YEngineer Repo t and As-Built _Y E.E // ETU Maintenance Contract provided Y_N E s6 f 1�C5 �fjRa c3? \ tt\4N ) kb--gJ ‘L_.--\--:- Location of System on Property: Front Rea Left Side Right Side Middle Front Middle Rear S stem Use Statu . Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report t Town o bury Building & Code Enforcement ff /� / Office No. (518) 761-8256 15! —1 Septic Inspection Report Inspection request received: WOG( Name: 5-c2/I(i-V I 't, ttf\J Inspected on: ii ` /_ ( V Location: 3 1& N r }C or, (: -_-1\ - Arrive: t a.m.l p.m. Permit No.: / - 3(0(-1 Inspector's Initials: • Comments andlor diagram Soil Type: Sand o lay Type of W r: unicip ell Water Waterline separa ion distance ft. Well separation distance ft. Other wells. ft. Well Casing Length 50'+/- Y N_NIA [150'to well required if NO] Absorption Field: Total length cno ft. Length of each trench A` ft. • Depth of trenches tit- ft. Size of Stone �.k Z Seepage Pits: Number H, r{` �, Size: N �x Stone Size. Piping Size Type Building to tank '4 ' ..2.14-AD Tank to Distribution Box 4 u �;�J�� `�,� Distribution Box to Field I Pit .l 3' k ``32 ,� Opening Sealed. N I End Cap —N Inlet/Outlet Pipes&BafflesT N Manholes 12"or less below grade Air,, N [provide extension collar if Yes] Y ' N !VC' - S',C� C � Location/Separations Foundation to tank I C) ft Foundation to absorption -9-13 ft. LIV:CDQThe �%`-"®"�`�$y� ��`��Separation of Pits [zeor UtConforms as per Plot Plan _Y I�/Engineer Report and As-Built Y V Nt 6 �n�a J� Q -ETU Maintenance Contract provided Y_NA- ��•� Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use Status: A's lived Y •artial Apprs -: :nd needs to be re-inspected, please call the Building&Codes Office .•Iroved Septic Inspection Report Rough Plumbing / Insulation Inspection Report - /D6L Office No. (518) 761-8256 Date Inspection re uest received: ///20��i7 Queensbury Building & Code Enforcement Arrive: 1�!I' am/pm 742 Bay Road, Quee ns `b �ury, NY 12804 ` Inspect r ni is s-_y 7 If NAME: Scvk V-v 1 e ( PERMIT#: / LOCATION: r% I 0 5 / X /N, gINSPECT ON: 0 / / TYPE OF STRUCTURE: f cy)..4)-4 Alar Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes Insulation /Residential Check/Commercial Check Window Sealing s 7- -5 _ Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: pav L),.I"StsL i h7 '5 S Rough Plumbing_Insulation Inspection_02 0513 • 1 ICYNENE ® THE EVOLUTION OF INSULATION INSULATION CERTIFICATE This form must be filled out and posted to comply with building code requirements. Meets MRC requirements: 2005 IRC-N1101.2,N1101.4,N1101.8 2009 IRC-N1101.2,N1101.4,N1101.8 2012 IRC-N1101.3,N1101.7,N1101.12 Ta foucwl ray polyure . ane foam •roduct(s)has/have been installed. LD-C-50 ■ LD-R-5 'MD-C-. 80 Q MD-R-200 ❑MD-R-210 ❑Other VZ .012„,,s XPrI— leaseconsuftInternationalBuildingCodeu C >_t• -Plastic and International Residential Code(CRC) 2006 IRC P314,2009 IRC R316,2012 IRC P316-Foam Plastics for specific requirements.The aforementioned Icynene spray polyurethane foam insulation system(s) has/have been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of: Area insulated/ Aged R-Value Thickness* Attic Area t74-t IE fl d(1U4_f(C R- L 2c at 5,b inches tO—t-St.v.L Sloped Ceilings R- 3E, at r/p,s° inches LO—C—$o V2. Walk(location): Ex-rea¢-10-44/4-)/s R- 2/ I at 3.7j uinches /�c5e nL_ � /05E-IN. ro a, "a'L+1 Walls (location): R- I at I � inches Floors(over an unheated crawl space) R- at { inches Crawl Space Perimeter R- at i I inches Basement Walls R- 1 at I inches Other(location): 1 R- at J I inches `FIominai thicknesses are muresentati,e\of held.spray-appled foam material. Jobsite Address (�fxotil f`G L7w.2cj , AIL1 Cls �l2aeXre /ex Date of Insulation Installation /U /Zv/y — it/2vfst Building Contractor e; F-v�.te Cont Sre. •=Trnal Insulation Contractor ,cJa t14 E45r spi--a-y AAw 1 Insulation Contractor Phone SLS G 23. 7o/c) installed By INSULATION CERTIFICATE • DO NOT REMOVE Please post near electrical panel ICYNENEInc.: 6747 Campobello Road Mississauga ON'L5N 2L7 Canada ICYNENE.0©M • • ICC EVALUATION �S SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1826* Reissued February 1, 2012 This report is subject to renewal February 1, 2013. www.icc-es.orq I (800)423-6587 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE 3.0 DESCRIPTION PROTECTION Section: 07 21 00—Thermal Insulation 3.1 General: Icynene LD-C-50"' and LD-C-50 v2 are low-density, open- REPORT HOLDER: cell, polyurethane foam plastic insulations and air barrier ICYNENE, INC. systems that are 100 percent water-blown with an installed nominal density of 0.5 pcf (8 kg/m3). The insulations are 6747 CAMPOBELLO ROAD two-component, spray-applied products The two MISSISSAUGA, ONTARIO L5N 2L7 components of the insulation are polymeric isocyanate CANADA (A-Component, also known as Base Seale)and proprietary (905)363-4040 resin (B-Component, LD-C-50 or LD-C-50 v2 Resin, also www.icvnene.com known as, Gold Seal®) The A-Component must be stored at a temperature of 50°F (10°C)or greater, and has a shelf EVALUATION SUBJECT: life of six months The B-Component must be stored at temperatures below 100°F (37.8°C), and has a shelf life of ICYNENE LD-C-50Th"AND LD-C-50 VERSION 2(v2) six months 1.0 EVALUATION SCOPE 3.2 Surface Burning Characteristics: Compliance with the following codes: When tested in accordance with ASTM E84/UL 723, at a • 2012 and 2009Intemational8u//ding Code®(2009 IBC) thickness of 6 inches (152 mm) and a nominal density of 0 5 pcf(8 kg/m3), Icynene LD-C-50 and LD-C-50 v2 have a • 2012 and 2009 International Residential Code® (2009 flame spread index of 25 or less and a smoke-developed IRC) index of 450 or less Thicknesses of up to 71/2 inches (190 5 mm) for wall cavities and 111/2 inches (292 mm) for • 2012 and 2009 International Energy Conservation ceiling cavities are recognized based on room comer fire Code®(2009 IECC) testing in accordance with NFPA 286, when covered with • Other Codes(see Section 8 0) minimum 1/2-inch-thick (13 mm) gypsum board or an equivalent thermal barrier complying with the applicable Properties evaluated: code • Surface burning characteristics 3.3 Thermal Resistance: • Physical properties Icynene LD-C-50 and LD-C-50 v2 have thermal resistance • Thermal performance(R-values) (R-values)at a mean temperature of 75°F(24°C)as shown • Attic and crawl space installation in Table 1. ■ Fire resistance 3.4 Air Permeability: • Air permeability Icynene LD-C-50" and LD-C-50 v2 spray-applied foam plastic insulations, at a minimum thickness of 3'/2 inches • Noncombustible construction (89 mm), are considered air-impermeable insulation in 2.0 USES accordance with IRC Section R202, based on testing in accordance with ASTM E283 Icynene L0C50TM and LD-C-50 v2 are used to provide 3.5 Intumescent Coatings: thermal insulation in buildings and to seal areas such as plumbing and wiring penetrations against air infiltration, in 3.5.1 No Burn Plus XD: No Burn Plus XD intumescent Types I, II, Ill, IV and Type V construction (IBC) and coating is a latex-based coating supplied in 1-gallon (4L) dwellings under the IRC The insulations may be used in and 5-gallon (19L) pails and 55-gallon (208 L) drums The fire-resistance-rated construction when installed in coating material has a shelf life of 12 months when stored accordance with Section 4 5 and in Types I through IV in factory-sealed containers at temperatures between 40°F construction when installed in accordance with Section 4 6. (4 4°C)and 90°F(32.2°C) *Revised November 2012 Ice-Ec Exaluatmn Ii ports are not in he construed as representing aesthetics or our other attributes not ApecrKa&A addressed.m,r are they to he construed TM ortit% as an endnnemenr of the subject of the report or a recommendation f hrvn ore !'here hs no warranty by l(T'Rralnannn 5envre.LL(',express or implied,as to any finding or other matter in this report,or as to an,product cm ere?by the repot ir Copyright®2012 ®sem Page 1 of 6 ,-t ESR-1826 I Most Widely Accepted and Trusted . Page 2 of 5 3.5.2 DC 315: DC 315 intumescent coating is a water- 4.4 Attics and Crawl Spaces: based coating supplied in 5-gallon (19L) pails and N 55-gallon (208L) drums The coating material has a shelf • 4.4.1 Application with a Prescriptive Ignition Barrier: life of 24 months when-stored in factory-sealed containers When Icynene LD-C-5OTM and LD-C-50 v2 foam plastic at temperatures between 41°F(5°C)and 95°F(35°C) insulations are installed within attics where entry is made only for service of utilities, an ignition barrier must be 4.0 INSTALLATION installed in accordance with IBC Section 2603.41 6 and 4.1 General: IRC Sections R316.5.3 and R316 5.4, as applicable The ignition barrier must be consistent with the requirements The manufacturer's published installation instructions and for the type of construction required by the applicable code this report must be strictly adhered to and a copy of these , and must be installed in a manner so that the foam plastic instructions and this evaluation report must be available on insulation is not exposed. The insulation may be installed the jobsite at all times during installation. in unvented attics in accordance with the 2009 IRC Section 4.2 Application: R806.4 or 2012 IRC Section R806.5, as applicable. Icynene LD-C-50 TM and LD-C-50 v2 foam plastic .4.2 Application without a Prescriptive Ignition insulations must be applied using spray equipment Barrier: Where Icynene LD-C-50 and LD-C-50 v2 foam specified by Icynene, Inc. The insulation must not be used plastic insulation is installed in an attic or crawl space in areas which have a maximum service temperature without a prescriptive ignition barrier, in accordance with greater than 180°F (82°C). The foam plastic insulation Sections 4.4 2.1, 4.4.2.2, 4 4.2.3 and 4.4.3, the following must not be used in electrical outlet or junction boxes or in conditions apply. contact with rain or water, and must be protected from the 1. Entry to the attic or crawl space is only for service of weather during and after application Where the insulation utilities and no storage is permitted. is used as air-impermeable insulation, such as in unventilated attic spaces regulated by IRC Section R806, 2 There are no interconnected attic, crawl space or • the insulation must be installed at a minimum thickness of basement areas. 3.5 inches (89 mm). The insulation can be installed in one 3. Air in the attic or crawl space is not circulated to other pass to the maximum thickness. Where multiple passes parts of the building. are required,the cure time between passes is negligible 4.3 Thermal Barrier: 4. Combustion air is provided in accordance with IMC Section 701. 4.3.1 Application with a Prescriptive Thermal Barrier: Icynene LD-C-50Tm and LD-C-50 v2 foam plastic 5 Attic ventilation is provided when required by IBC insulations must be separated from the interior of the Section 12032 or IRC Section R806, except when building by an approved thermal barrier, such as 1/2-inch air-impermeable insulation is permitted in unvented (12.7 mm) gypsum wallboard installed using mechanical attics in accordance with Section R806 4 of the 2009 fasteners in accordance with the applicable code, or an IRC or Section R806.5 of the 2012 IRC. equivalent 15-minute thermal barrier complying with the 6. Under-floor (crawl space) ventilation is provided when applicable code. When installation is within an attic or required by IBC Section 12033 or IRC Section crawl space as described in Section 4 4, a thermal barrier R408 1, as applicable. is not required between the foam plastic and the attic or crawl space, but is required between the foam and the 4.4.2.1 Attics — LD-C-50 and LD-C-50 v2: In attics interior of the building Thicknesses of up to 7112 inches Icynene LD-C-50TH LD-C-50 v2 foam plastic insulation (190 5 mm)for wall cavities and 111/2 inches (292 mm)for may be spray-applied to the underside of the roof ceiling cavities are recognized based on room corner fire sheathing and/or rafters, as described in this section The testing in accordance with NFPA 286, when covered with thickness of the foam plastic applied to the underside of minimum 1/2-inch-thick (13 mm) gypsum board or the roof sheathing must not exceed 14 inches (356 mm). equivalent thermal barrier complying with, the applicable The thickness of the spray foam insulation applied code to vertical wall surfaces must not exceed 5.5 inches 4.3.2 Application without a Prescriptive Thermal (140 mm). The insulation must be covered on all surfaces Barrier2or Ignition Barrier: The with one of the coatings described in Section 3.5 The 9 prescriptive 15-minute coating must be applied over the insulation in accordance thermal barrier or ignition barrier may be omitted when with the coating manufacturer's instructions and this report. installation is in accordance with this section. The Surfaces to be coated must be dry, clean, and free of dirt, insulation and coating may be spray-applied to the interior loose debris and other substances that could interfere with facing of walls, the underside or roof sheathing of roof adhesion of the coating. The coating is applied in one coat rafters, and in crawl spaces, and may be left exposed as with low-pressure airless spray equipment The coating an interior finish without a prescribed 15-minute thermal must be applied to a thickness as follows. barrier or ignition barrier The thickness of the foam plastic applied to the underside of the roof sheathing must not • No Burn Plus XD at a minimum dry film thickness of exceed 14 inches (356 mm). The thickness of the spray 4 mils(6 wet mils)at 270 ft2 per gallon. foam insulation applied to vertical wall surfaces must not • DC 315 at a minimum dry film thickness of 3 mils(4 wet exceed 6 inches (152 mm). The foam plastic must be mils)at 400 ft2 per gallon covered on all surfaces with DC 315 coating at a minimum thickness of 13 dry mils, 20 wet mils, 80 ft2 per gallon The The coatings must be applied when ambient and coating must be applied over the insulation in accordance substrate temperature is at least 60°F (16°C) and no more with the coating manufacturer's instructions and this report. than 95°F (35°C). All other surfaces (including glass) must Surfaces to be coated must be dry, clean, and free of dirt, be protected against damage from the coating The loose debns and other substances that could interfere with insulation may be installed in unvented attics when the adhesion of the coating The coating is applied in one coat foam plastic is applied at a minimum thickness of 3.5 with low-pressure airless spray equipment inches (89 mm) as described in this section in accordance ESR-1826 I Most Widely Accepted and Trusted r Page 3 of 5 with the 2009 IRC Section R806.4 or Section R806.5 of the face, attached with 8d box nails, 21/2 inches (64 mm) long 2012 IRC. and spaced 7 inches (178 mm) on center along the studs , for the face layer and 6d cement coated box nails,2 inches 4.4.2.2 Attics — LD-C-50 v2: When LD-C-50 v2 is applied in unvented attics conforming to 2012 IRC Section (51 mm) long and spaced 24 inches (610 mm) on center R806.5 or 2009 IRC Section R806.4,the insulation may be along the studs The stud cavity contains Icynene applied to the underside of roof sheathing and/or rafters to insulation nominally 2 inches(51 mm)thick a minimum thickness of 51/2 inches (140 mm) and a Axial loads applied to the wall assembly must be limited minumum thickness of 11/2 inches (38 mm) over the to the least of the following rafters; and may be applied to vertical wall surfaces to a minimum thickness of 51/2 inches (140 mm) and a • 1,805 pounds(8029 N)per stud. minumum thickness of 11/2 inches(38 mm) over the studs. ■ Design stress of 0 78 Pc Maximum thickness on the underside of roof sheathing or on vertical wall surfaces is 20 inches (508 mm) The • Design stress of 0.78 Pc at a maximum lJd of 33. insulation may be left exposed to the attic without a prescriptive ignition barrier or an intumescent coating 2-b.3 Assembly 3 (Floor/Ceiling):(38ili mm Minimum5 nominally 2-by-10 [1 /z by 9 /a inches (38 by 235 mm)] Douglas The attic must have attic access complying with IRC fir, No 2 grade wood joists spaced 24 inches(610 mm)on Section R807, horizontally placed in the floor, and opening center, with minimum 1-by-3 [3/4 by 21/2 inches (19 1 by outward toward the living space Items penetrating the roof 64 mm)] spruce bndging at mid-span. Floor decking must deck or walls, such as skylight wells and vents, must be be minimum 1/2-inch-thick (12.7 mm) exterior grade covered with a minimum of 51/2 inches (140 mm) of the plywood installed perpendicular to joists and fastened with LD-C-50 v2 insulation. 2-inch-long(51 mm)ring shank nails 6 inches(152 mm)on center at the joints and 12 inches (305 mm) on center at 4.4.2.3 Crawl Spaces: In crawl spaces, Icynene LD-C- 50 and LD-C-50 v2 insulation may be spray-applied to the intermediate joists.ltimust Plywood jointslimust occurndside vertical walls and the underside of floors, as described in joists. Icynene insulation must be applied to the underside this section. The thickness of the foam plastic applied to of the plywood deck between the joists to a depth of 5 the underside of the floors must not exceed 14 inches (15.9 s mm),(12TypemmTwo layersmwallboard of dimum be attached (356 mm). The thickness of the spray foam insulation perpendicular X gypsum must be attf the applied to vertical wall surfaces must not exceed 31/2 smbl . The to the joists on the attacheddg side of the inches (88.9 mm). The foam plastic does not require an assembly. firstyplayer must be ws, spacedh 24/inches ignition barrier or a coating. long (32 mm), Type W drywall screws, inches (610 mm) on center The second layer must be applied 4.4.3 Use on Attic Floors: When used on attic floors, perpendicular to the joists, offset 24 inches(610 mm) from Icynene LD-C-50TH and LD-C-50 v2 foam plastic insulation the base layer The second layer must be attached with may be installed at a maximum thickness of 111/2 inches 2-inch-long (51 mm), Type S drywall screws spaced 12 (292 mm)between joists in attic floors. The insulation must inches (305 mm) on center. Additional fasteners must be be separated from the interior of the building by an installed along the butt joints of the second layer, securing approved thermal barrier. The coatings specified in in the two layers together. These fasteners must be 11/2-inch- Section 4 4 2.1 and the ignition bamer in accordance with long (38 mm), Type G drywall screws placed 2 inches IBC Section 2603.4.1.6 and IRC Section R316 5.3, may be (51 mm) back from each end of the butt joint and spaced omitted. 12 inches(305 mm) on center. The wallboard joints on the 4.5 One-hour Fire-resistance-rated Assemblies: exposed side must be treated with paper tape embedded in joint compound and topped with an added coat of 4.5.1 Assembly 1 (Limited Load-bearing Wood Stud compound, and the fastener heads must be coated with Wall): Minimum nominally 2-by-4 [11/2 by 31/2 inches joint compound in accordance with ASTM C840 or (38 mm by 89 mm)]southern pine (G =0.55), No. 2 grade GA-216. studs spaced 16 inches (406 mm) on center with a base layer of 1/2-inch-thick (12 7 mm) wood fiber sound board 4.5.4 Assembly 4 (Non-loadbearing Steel Stud Wall): installed horizontally on each face with vertical joints Nominally 6-inch-deep (152.4 mm), No 18 gage, located over the studs, attached with 6d box nails, 2 inches galvanized steel studs spaced 16 inches (406 4 mm) on (51 mm) long and spaced 24 inches (610 mm) on center center, are friction-fit into No. 18 gage galvanized steel along the studs, and a second layer of 3/e-inch-thick floor and ceiling track with a layer of 5/8-inch-thick (15.9 mm)Type X gypsum wallboard installed vertically on (15 9 mm t),Type he ton X gypsum board applied to the interior each face, attached with 8d box nails, 21/2 inches (64 mm) side with the long edge parallel to steel studs and secured using No 6, 11/4-inch-long (31.7 mm), self- drilling drywall long and spaced 7 inches (178 mm) on center along the studs. The stud cavity contains Icynene insulation screws spaced 8 inches (203 mm) on center around the nominally 2 inches(51 mm)thick. perimeter and 12 inches (305 mm) on center in the field. The gypsum board joints must be treated with vinyl or Axial loads applied to the wall assembly must be limited casein, dry or premixed joint compound applied in two to the least of the following. coats to cover all exposed screw heads and gypsum board • 1,805 pounds(8029 N)per stud butt joints, and a minimum 2-inch-wide (51 mm) paper, plastic, or fiberglass tape embedded in the first layer of • Design stress of 0 78 Pc compound over butt joints of the gypsum board. The stud • Design stress of 0.78 Pc at a maximum I�/d of 33. cavity is filled with Icynene insulation up to 6 inches (152 mm) thick. DensGlasse Gold Exterior Sheathing, 4.5.2 Assembly 2 (Limited Load-hearing Wood Stud /2 inch (12.7 mm) thick, is installed parallel to steel studs Wall): Minimum nominally 2-by-4 [11/2 by 31/2 inches with vertical joints offset a minimum of 16 inches 406 mm) (38 mm by 89 mm)]southern pine (G =0 55), No. 2 grade from the vertical joints of the gypsum board and the studs spaced 16 inches (406 mm) on center with two horizontal joints offset a minimum of 24 inches (610 mm) layers of 1/2-inch-thick (12 7 mm) Type X gypsum from the horizontal joints of the gypsum board. The wallboard installed vertically with joints staggered on each sheathing is attached using No. 6, 11/4-inch-long ESR-1826 I Most Widely Accepted and Trusted Page 4 of 5 (31.7 mm), self-drilling drywall screws spaced 8 inches 5.1 This evaluation report and the manufacturer's (203 mm) on center around the perimeter and in the field. published installation instructions, when required by Hohmann & Barnard DW-10 brick ties, 6 inches (152 mm) the code official, must be submitted at the time of long by 11/2-inches (38 mm) wide, are spaced 16 inches permit application. (406.4 mm) on center vertically on each steel stud, and secured, using two 15/8-inch-long (41.3 mm) self-drilling 5.2 The insulation must be installed in accordance with screws,through 4-inch(102 mm)red clay brick[3'/2 inches the manufacturer's published installation instructions, (88.9 mm) by 21/4 inches (57.1 mm) by 73/4 inches this evaluation report and the applicable code If there (197 mm)] laid in a running bond pattern with Type S is a conflict between the installation instructions and mortar, leaving a nominally 1-inch (25.4 mm) air gap this report, this report governs between the brick and the exterior sheathing. 5.3 The insulation must be separated from the interior of Optithe building by an approved 15-minute thermal Optional' It is permitted to add code-complying, expanded polystyrene (EPS), extruded polystyrene (XPS), barrier, except when installation is as described in foil-faced, rigid polyurethane board stock or polyurethane Section 4.3.2 or in attics and crawl spaces as spray foam on the exterior of the wall (between the described in Section 4.4.2 and 4.4.3. DensGlass® Gold sheathed wall and the brick), while 5.4 Since the performance of LD-C-50 v2, when installed maintaining the 1-inch (25.4 mm) air space The length of in unvented attics without a code-prescribed ignition the brick ties must be increased to account for the barrier or an intumescent coating, is based on fire thickness of the insulation performance of an unvented attic, the installation 4.6 Exterior Walls in Type I, II, III and IV Construction: must be approved by the code official as conforming with the provisions of Section 4.4 2 2 and Conditions 4.6.1 General:When used on exterior walls of Types I, II, 1 to 5 of Section 4.4.2. III or IV construction, the assembly must comply with IBC 5.5 The insulation must not exceed the thickness and Section 2603.5 and this section, and the LD-C-50 and LD-C-50 v2 insulation must be installed at a maximum density noted in Sections 3 2,4.3,4.4,4.5 and 4 6 thickness of 6 inches (152 mm). The potential heat of 5.6 The insulation must be protected from the weather Icynene LD-C-50 and LD-C-50 v2 insulation is 494 Btu/ft2 dunng and after application. (5.6 MJ/m2) per inch of thickness, when testing is in 5.7 The insulation must be applied bylicensed dealers accordance with NEPA 259. PP and installers certified by Icynene, Inc. 4.6.2 Exterior Face: Nominally 6-inch-deep (152 mm), 5.8 Use of the insulation in areas where the probability of No. 18 gage, galvanized steel studs spaced 16 inches (406 mm) on center, are fastened to No. 18accordancere infestation is "very heavy mustC ee in gage, 3with IRC Section R318.4 or IBC Section Zgalvanized steel floor and ceiling track using No. 8, 2603.8, as applicable /e-inch-long (22.2 mm�, self-tapping pan head framing screws. GP DensGlass® Gold Exterior Sheathing, 1/2 inch 5.9 Jobsite certification and labeling of the insulation must (12.7 mm) thick, is installed over the exterior side of steel comply with IRC Sections N1101.4 and N1101.4.1 studs with the long end perpendicular to the steel studs, and IECC Sections 303.1.1 and 303.1 2, as using No. 6, Type S, 11/4-inch (31.7 mm), self-tapping applicable. bugle head screws spaced 8 inches (203 mm) on center 5.10 When LD-C-50 v2 insulation is installed under around the perimeter and in the field. The stud cavity is Section 4 4 2.2 of this report, a certificate must be filled with Icynene insulation to a nominal thickness of placed in the attic stating that the foam plastic 6 inches(152 mm). insulation has been installed in accordance with 4.6.3 Interior Face: Type X gypsum board, 5/8 inches Conditions 1 to 5 of Section 44.2 and the terms of (15.9 mm) thick, is installed with the long dimension Section 442.2 of ESR-1826; any alterations to the perpendicular to steel studs with No. 6, Type S, 11/4 inch- attic or insulation must be consistent with those long (31.7 mm), self-tapping, bugle head screws spaced 8 requirements. inches(203 mm)on center around the perimeter and in the 5.11 A vapor retarder must be installed in accordance field The gypsum board joints must be treated with vinyl or with the applicable code. casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board 5.12 Icynene LD-C-50 and LD-C-50 v2 foam plastic butt joints, and a minimum 2-inch-wide (51 mm) paper, insulation are manufactured in Mississauga, Ontario, plastic, or fiberglass tape embedded in the first layer of Canada, under a quality control program with compound over butt joints of the gypsum board. inspections by Intertek Testing Services(AA-691). 4.6.4 Exterior Wall Covering: Details of the exterior wall 6.0 EVIDENCE SUBMITTED covering must be provided to the code official by the report 6.1 Data in accordance with the ICC-ES Acceptance holder, designer or specifier, with an engineenng analysis Criteria for Spray-applied Foam Plastic Insulation demonstrating that (1) the exterior wall covenng conforms (AC377), dated June 2011, including reports of tests to ASTM E136 and (2)the addition of the wall covering to in accordance with Appendix X (Section 44.2.1) and the assembly described in this section does not negatively Appendix C (Section 4.4 2.2) affect conformance of the assembly with the requirements of IBC Section 2603.5. 6.2 Test report on air leakage rate in accordance with 5.0 CONDITIONS OF USE ASTM E283 ,M 6.3 Reports of room corner fire testing in accordance with The Icynene LD-C-50 and LD-C-50 v2 spray-applied NFPA 286 polyurethane foam plastic insulations described in this report comply with, or are suitable alternative to what is 6.4 Test reports in accordance with ASTM E119. specified in,those codes listed in Section 1 0 of this report, 6.5 Test report in accordance with NFPA 285, and related subject to the following conditions' engineering analysis. ESR-1826 I Most Widely Accepted and Trusted Page 5 of 5 6.6 Reports of tests in accordance with NFPA 259 8.2 Uses: 6.7 Reports of fire tests in accordance with ASTM E970. The products comply with the above-mentioned codes as 6.8 For LD-C-50 v2, an engineering evaluation, including described in Sections 2.0 to 7 0 of this report, with the full-scale fire testing, small-scale testing and fire revisions noted below modeling • Application with a Prescriptive Ignition Barrier: See 7.0 IDENTIFICATION Section 4.4 1, except attics must be vented in LD-C-5OTM and accordance with 2006 IBC Section 1203.2, and crawl All packages and containers of lcynene space ventilation must be in accordance with 2006 IBC LD-C-50 v2 must be labeled with the Icynene, Inc, name Section 1203.3, as applicable. Additionally, an ignition and address; the product name; the flame spread index bamer must be installed in accordance with 2006 IRC and the smoke-developed index; the shelf life expiration Section R314 5 3 or R314 5 4, as applicable. date; t s),he lanndlthof the in sti ncrieporton g number(ESRency k1826) .ng • Application without a Prescriptive Ignition Barrier See Section 4.4.2, except attics must be vented in Intumescent coatings are identified with the manufacturer's name and address,the product trade name accordancetionR806with Sectionthe2006 IRC,2 the 2006 IBC or Section of the and crawl space and use instructions. ventilation must be in accordance with Section 1203.3 of 8.0 OTHER CODES the 2006 IBC or Section R408 of the 2006 IRC, as applicable 8.1 Scope: In addition •to the codes referenced in Section 1 0, the • Jobsite Certification and Labeling See Section 5 8, products recognized ine this report were evaluated for except jobsite certification and labeling must comply with Sections 102.1.1 and 102.1.11, as applicable, of compliance with the requirements of the following codes: the 2006 IECC • 2006 International Building Code(2006 IBC) • Protection Against Termites See Section 5 7, except • 2006 International Residential Code®(2006 IRC) use of the insulation in areas where the probability of • 2006 International Energy Conservation Code termite infestation is "very heavy must be in (2006 IECC) accordance with Section R320.5 of the 2006 IRC TABLE 1—THERMAL RESISTANCE(R-VALUES)FOR LD-C-50 and LD-C-50 v2 THICKNESS(inches) R-VALUE(°F•ft2-h/Btu) 1 37 2 7 3 11 35 13 4 14 5 18 5 5 20 6 22 7 25 7 5 27 8 29 9 32 9.5 34 10 36 11.5 41 14 50 20 74 For SI: 1 inch=25 4 mm, 1°F-ft-h/Btu=0.176 110°K-m2/W. 1R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses 2R-values greater than 10 are rounded to the nearest whole number E� ICC EVALUATION �S SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1826" Reissued February 1, 2012 This report is subject to renewal February 1, 2013. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE 3.0 DESCRIPTION PROTECTION Section: 07 21 00—Thermal Insulation 3.1 General: REPORT HOLDER: Icynene LDC50TM and LD-C-50 v2 are low-density, open- cell, polyurethane foam plastic insulations and air barrier ICYNENE, INC. systems that are 100 percent water-blown with an installed 6747 nominal density of 0.5 pcf (8 kg/m'). The insulations are 6747 CAMPOBELLOSMPOB, ROADA LSN 2L7 two-component, spray-applied products. The two CANADA components of the insulation are polymeric isocyanate (905)363-4040 (A-Component, also known as Base Seal®)and proprietary resin (B-Component, LD-C-50 or LD-C-50 v2 Resin, also www.icvnene.com known as, Gold Seal®) The A-Component must be stored EVALUATION SUBJECT: at a temperature of 50°F(10°C) or greater, and has a shelf life of six months The B-Component must be stored at ICYNENE LD-C-50"" AND LD-C-50 VERSION 2(v2) temperatures below 100°F (37.8°C), and has a shelf life of six months. 1.0 EVALUATION SCOPE 3.2 Surface Burning Characteristics: Compliance with the following codes: When tested in accordance with ASTM E84/UL 723, at a thickness of 6 inches (152 mm) and a nominal density of • 2012 and 2009 International Building Code®(2009 IBC) 0.5 pcf(8 kg/m3), Icynene LD-C-50 and LD-C-50 v2 have a • 2012 and 2009 International Residential Code® (2009 flame spread index of 25 or less and a smoke-developed IRC) index of 450 or less Thicknesses of up to 71/2 inches (190 5 mm)for wall cavities and 111/2 inches (292 mm)for • 2012 and 2009 International Energy Conservation ceiling cavities are recognized based on room corner fire Code®(2009 IECC) testing in accordance with NFPA 286, when covered with • Other Codes(see Section 8.0) minimum 1/2-inch-thick (13 mm) gypsum board or an equivalent thermal barrier complying with the applicable Properties evaluated: code • Surface burning characteristics 3.3 Thermal Resistance: • Physical properties Icynene LD-C-50 and LD-C-50 v2 have thermal resistance • Thermal performance(R-values) (R-values)at a mean temperature of 75°F(24°C)as shown • Attic and crawl space installation in Table 1 ■ Fire resistance 3.4 Air Permeability: • Air permeability Icynene LDC.50TM and LD-C-50 v2 spray-applied foam plastic insulations, at a minimum thickness of 31/2 inches • Noncombustible construction (89 mm), are considered air-impermeable insulation in 2.0 USES accordance with IRC Section R202, based on testing in accordance with ASTM E283 Icynene LIJC50TM and LD-C-50 v2 are used to provide 3.5 Intumescent Coatings: thermal insulation in buildings and to seal areas such as plumbing and wiring penetrations against air infiltration, in 3.5.1 No Bum Plus XD: No Burn Plus XD intumescent Types I, II, Ill, IV and Type V construction (IBC) and coating is a latex-based coating supplied in 1-gallon (4L) dwellings under the IRC The insulations may be used in and 5-gallon (19L) pails and 55-gallon (208 L) drums The fire-resistance-rated construction when installed in coating material has a shelf life of 12 months when stored accordance with Section 4,5 and in Types I through IV in factory-sealed containers at temperatures between 40°F construction when installed in accordance with Section 4.6. (4.4°C)and 90°F(32 2°C). *Revised November 2012 it'GE.S Evaluation Reptant are not to be construed as representing aesthetics or ant,other anrrhurec not peel',ally addres red,nor are they to he capsized or an endorsement of the cuheect of!he repast or a recantmendationfor its use Mere is no warning'hr RT'Evalumton Service.1.11,erprert or rmpbed,a utir 0 m arnf acing or other matter m this report,or as to any product covered by the report Copyright 'Han —_ Page 1 of 5 ESR-1826 I Most Widely Accepted and TrustedT Page 2 of 5 3.5.2 DC 315: DC 315 intumescent coating is a water- 4.4 Attics and Crawl Spaces: based coating supplied in 5-gallon (19L) pails and 55-gallon (208L) drums The coating material has a shelf 4.4.1 Application with a Prescriptive Ignition Barrier: life of 24 months when stored in factory-sealed containers When Icynene LD-C-501M and LD-C-50 v2 foam plastic insulations are installed within attics where entry is made at temperatures between 41°F(5°C)and 95°F(35°C) 4.0 INSTALLATION only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603 4.1.6 and 4.1 General: IRC Sections R316 5 3 and R316 5.4, as applicable. The ignition barrier must be consistent with the requirements The manufacturer's published installation instructions and for the type of construction required by the applicable code this report must be strictly adhered to and a copy of these and must be installed in a manner so that the foam plastic instructions and this evaluation report must be available on insulation is not exposed The insulation may be installed the jobsite at all times during installation. in unvented attics in accordance with the 2009 IRC Section 4.2 Application: R806.4 or 2012 IRC Section R806 5, as applicable Icynene LD-C-50 TM and LD-C-50 v2 foam plastic 4.4.2 Application without a Prescriptive Ignition insulations must be applied using spray equipment Barrier: Where Icynene LD-C-50 and LD-C-50 v2 foam specified by Icynene, Inc. The insulation must not be used plastic insulation is installed in an attic or crawl space in areas which have a maximum service temperature• without a prescriptive ignition barrier, in accordance with greater than 180°F (82°C). The foam plastic insulation Sections 4.4.2.1, 4 4.2.2, 4.4.2.3 and 4.4 3, the following must not be used in electrical outlet or junction boxes or in conditions apply' contact with rain or water, and must be protected from the 1. Entry to the attic or crawl space is only for service of weather during and after application. Where the insulation is used as air-impermeable insulation, such as in utilities and no storage is permitted. unventilated attic spaces regulated by IRC Section R806, 2. There are no interconnected attic, crawl space or the insulation must be installed at a minimum thickness of basement areas. 3.5 inches (89 mm) The insulation can be installed in one 3. Air in the attic or crawl space is not circulated to other pass to the maximum thickness Where multiple passes are required,the cure time between passes is negligible. parts of the building. 4.3 Thermal Barrier: 4. Combustion air is provided in accordance with IMC Section 701 4.3.1 Application with a Prescriptive Thermal Barrier: Icynene LD-C-SOT'" and LD-C-50 v2 foam plastic 5. Attic ventilation is provided when required by IBC insulations must be separated from the interior of the Section 1203.2 or IRC Section R806, except when building by an approved thermal barrier, such as 1/2-inch air-impermeable insulation is permitted in unvented (12.7 mm) gypsum wallboard installed using mechanical attics in accordance with Section R806.4 of the 2009 fasteners in accordance with the applicable code, or an IRC or Section R806 5 of the 2012 IRC. equivalent 15-minute thermal barrier complying with the 6. Under-floor (crawl space) ventilation is provided when applicable code. When installation is within an attic or required by IBC Section 1203 3 or IRC Section crawl space as described in Section 4.4, a thermal barrier R408 1, as applicable. is not required between the foam plastic and the attic or crawl space, but is required between the foam and the 4.4.2.1 Attics — LD-C-50 and LD-C-50 v2: In attics interior of the building Thicknesses of up to 71/2 inches Icynene LD-C-50Tr^ LD-C-50 v2. foam plastic insulation (190.5 mm) for wall cavities and 111/2 inches (292 mm) for may be spray-applied to the underside of the roof ceiling cavities are recognized based on room corner fire sheathing and/or rafters, as described in this section. The testing in accordance with NFPA 286, when covered with thickness of the foam plastic applied to the underside of minimum 1/2-inch-thick (13 mm) gypsum board or the roof sheathing must not exceed 14 inches (356 mm). equivalent thermal bamer complying with, the applicable The thickness of the spray foam insulation applied code. to vertical wall surfaces must not exceed 5.5 inches 4.3.2 Application without a Prescriptive Thermal (140 mm) The insulation must be covered on all surfaces Barrier or Ignition Barrier: The prescriptive 15-minute with one of the coatings described in Section 3.5. The thermal barrier or ignition barrier may be omitted when coating must be applied over the insulation in accordance installation is in accordance with this section. The with the coating manufacturer's instructions and this report. insulation and coating may be spray-applied to the interior Surfaces to be coated must be dry, clean, and free of dirt, loose debris and other substances that could interfere with facing of walls, the underside or roof sheathing of roof rafters, and in crawl spaces, and may be left exposed as adhesion r the re coating. The coatingyisapplied in one coat an interior finish without a prescribed 15-minute thermal withulow-pressure to airless spray equipment The coating barrier or ignition barrier. The thickness of the foam plastic must be applied to a thickness as follows' applied to the underside of the roof sheathing must not • No Burn Plus XD at a minimum dry film thickness of exceed 14 inches (356 mm). The thickness of the spray 4 mils(6 wet mils)at 270 ft2 per gallon. foam insulation applied to vertical wall surfaces must not exceed 6 inches (152 mm) The foam plastic must be • DC 315 at a minimum dry film thickness of 3 mils(4 wet covered on all surfaces with DC 315 coating at a minimum mils)at 400 ft2 per gallon thickness of 13 dry mils, 20 wet mils, 80 ft2 per gallon The The coatings must be applied when ambient and coating must be applied over the insulation in accordance substrate temperature is at least 60°F(16°C)and no more with the coating manufacturer's instructions and this report than 95°F (35°C). All other surfaces (including glass) must Surfaces to be coated must be dry, clean, and free of dirt, be protected against damage from the coating. The loose debris and other substances that could interfere with insulation may be installed in unvented attics when the adhesion of the coating The coating is applied in one coat foam plastic is applied at a minimum thickness of 3.5 with low-pressure airless spray equipment. inches(89 mm)as described in this section in accordance • ESR-1826 I Most Widely Accepted and Trusted ' Page 4 of 5 (31.7 mm), self-drilling drywall screws spaced 8 inches 5.1 This evaluation report and the manufacturer's (203 mm) on center around the perimeter and in the field published installation instructions, when required by Hohmann & Barnard DW-10 brick ties, 6 inches (152 mm) the code official, must be submitted at the time of long by 11/2-inches (38 mm) wide, are spaced 16 inches permit application. (4064 mm) on center vertically on each steel stud, and 5.2 The insulation must be installed in accordance with secured, using two 15/8-Inch-long (41.3 mm) self-drilling screws, through 4-inch(102 mm)red clay brick[31/2 inches the manufacturer's published installation instructions, (88.9 mm) by 21/4 inches (57.1 mm) by 73/4 inches this evaluation report and the applicable code. If there (197 mm)] laid in a running bond pattern with Type S is a conflict between the installation instructions and mortar, leaving a nominally 1-inch (25.4 mm) air gap this report, this report governs. between the brick and the exterior sheathing 5.3 The insulation must be separated from the interior of Optional: It is permitted to add code-complying, the building by an approved 15-minute thermal expanded polystyrene (EPS), extruded polystyrene (XPS), barrier, except when installation is as described in foil-faced, rigid polyurethane board stock or polyurethane Section 43.2 or in attics and crawl spaces as spray foam on the exterior of the wall (between the described in Section 4.4.2 and 4 4.3. DensGlass® Gold sheathed wall and the brick), while 5.4 Since the performance of LD-C-50 v2, when installed maintaining the 1-inch (25.4 mm) air space. The length of in unvented attics without a code-prescribed ignition the brick ties must be increased to account for the barrier or an intumescent coating, is based on fire thickness of the insulation performance of an unvented attic, the installation 4.6 Exterior Walls in Type I, II, Ill and IV Construction: must be approved by the code official as conforming with the provisions of Section 4.4 2.2 and Conditions 4.6.1 General:When used on exterior walls of Types I, II, 1 to 5 of Section 4.4.2 III or IV construction, the assembly must comply with IBC Section 2603 5 and this section, and the LD-C-50 and 5.5 The insulation must not exceed the thickness and LD-C-50 v2 insulation must be installed at a maximum density noted in Sections 3.2,4.3,4.4, 4.5 and 4 6. thickness of 6 inches (152 mm) The potential heat of 5.6 The insulation must be protected from the weather Icynene LD-C-50 and LD-C-50 v2 insulation is 494 Btu/ft2 during and after application. (56 MJ/m2) per inch of thickness, when testing is in accordance with NFPA 259 5.7 The insulation must be applied by licensed dealers 1 and installers certified by Icynene, Inc. 4.6.2 Exterior Face: Nominally 6-inch-deep (152 mm), 5.8 Use of the insulation in areas where the probability of No. 18 gage, galvanized steel studs spaced 16 inches (406 mm) on center, are fastened to No. 18 gage, accordancere infestation is "very R318.4heav4" mustC be in galvanized steel floor and ceiling track using No 8, with IRC Section or IBC Section /e-inch-long (22.2 mm), self-tapping pan head framing 2603.8, as applicable. screws GP DensGlassy Gold Exterior Sheathing, 1/2 inch 5.9 Jobsite certification and labeling of the insulation must (12.7 mm) thick, is installed over the exterior side of steel comply with IRC Sections N1101.4 and N1101.4 1 studs with the long end perpendicular to the steel studs, and IECC Sections 303 1 1 and 303.1.2, as using No. 6, Type S, 11/4-inch (31 7 mm), self-tapping applicable bugle head screws spaced 8 inches (203 mm) on center 5.10 When LD-C-50 v2 insulation is installed under around the perimeter and in the field. The stud cavity is filled with Icynene insulation to a nominal thickness of pec4. h.2 of this report, a certificatemustbe 6 inches(152 mm). placeedd t in the attic stating that the foam plastic insulation has been installed in accordance with 4.6.3 Interior Face: Type X gypsum board, 5/8 inches Conditions 1 to 5 of Section 4.4.2 and the terms of (15 9 mm) thick, is installed with the long dimension Section 4 4.2.2 of ESR-1826; any alterations to the perpendicular to steel studs with No. 6, Type S, 11/4 inch- attic or insulation must be consistent with those long (31.7 mm), self-tapping, bugle head screws spaced 8 requirements. inches(203 mm)on center around the penmeter and in the 5.11 A vapor retarder must be installed in accordance field. The gypsum board joints must be treated with vinyl or with the applicable code. casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board 5.12 Icynene LD-C-50 and LD-C-50 v2. foam plastic butt joints, and a minimum 2-inch-wide (51 mm) paper, insulation are manufactured in Mississauga, Ontario, plastic, or fiberglass tape embedded in the first layer of Canada, under a quality control program with compound over butt joints of the gypsum board inspections by Intertek Testing Services(AA-691) 4.6.4 Exterior Wall Covering: Details of the exterior wall 6.0 EVIDENCE SUBMITTED covering must be provided to the code official by the report 6.1 Data in accordance with the ICC-ES Acceptance holder, designer or specifier, with an engineering analysis Criteria for Spray-applied Foam Plastic Insulation demonstrating that (1) the exterior wall covenng conforms (AC377), dated June 2011, including reports of tests to ASTM E136 and (2)the addition of the wall covering to in accordance with the assembly described in this section does not negatively Appendix X (Section 4.4.2.1) and affect conformance of the assembly with the requirements Appendix C (Section 4.4.2 2) of IBC Section 2603.5. 6.2 Test report on air leakage rate in accordance with 5.0 CONDITIONS OF USE ASTM E283. The Icynene LD-C-50T^' and LD-C-50 v2 s ra -a lied 6.3 Reports of room corner fire testing in accordance with p y pp NFPA 286. polyurethane foam plastic insulations described in this report comply with, or are suitable alternative to what is 6.4 Test reports in accordance with ASTM E119 specified in,those codes listed in Section 1.0 of this report, 6.5 Test report in accordance with NFPA 285, and related subject to the following conditions: engineering analysis. • ESR-1826 I Most Widely Accepted and Trusted Page 5 of 5 6.6 Reports of tests in accordance with NFPA 259 8.2 Uses: 6.7 Reports of fire tests in accordance with ASTM E970 The products comply with the above-mentioned codes as 6.8 For LD-C-50 v2, an engineering evaluation, including described in Sections 2.0 to 7 0 of this report, with the full-scale fire testing, small-scale testing and fire revisions noted below modeling • Application with a Prescriptive Ignition Barrier: See 7.0 IDENTIFICATION Section 44.1, except attics must be vented in TM' and accordance with 2006 IBC Section 12032, and crawl All packages and containers of Icynene LD-C-50 LD-C-50 v2 must be labeled with the Icynene, Inc., name Sectionpace ven1203tilation asapmust li in accordance. Additionally,with 2006IBC and address; the product name; the flame spread index stbe, ain ac orncewiignition P barriereciomust installedrR31 .5 accordance with 2006 IRC and the smoke-developed index, the shelf life expiration Section R314.5.3 or R314.5.4, as applicable date; the label of the inspection agency (Intertek Testing Services); and the evaluation report number(ESR-1826) • APPlication without a Prescriptive Ignition Barrier See Section 4.4.2, except attics must be vented in Intumescent coatings are identified with the manufacturer's name and address,the product trade name accordanceeorR806with Section 12036 2 IRC, the 2006 IBC or Section of the 2006 and crawl space and use instructions. ventilation must be in accordance with Section 1203 3 of 8.0 OTHER CODES the 2006 IBC or Section R408 of the 2006 IRC, as 8.1 Scope: applicable. In addition •to the codes referenced in Section 1.0, the • Jobsite Certification and Labeling: See Section 5.8, products recognized in this report were evaluated for except jobsitetioscertification2 .1a1a02d labelings ppli comply compliance with the witheSections 102 1.1 and 102.1 11, as applicable, of P requirements of the following codes: the 2006 IECC. • 2006 International Building Code®(2006 IBC) • Protection Against Termites: See Section 5 7, except • 2006 International Residential Code®(2006 IRC) use of the insulation in areas where the probability of • 2006 International Energy Conservation Code° termite infestation is "very heavy" must be in (2006 IECC) accordance with Section R320 5 of the 2006 IRC. { TABLE 1—THERMAL RESISTANCE(R-VALUES)FOR LD-C-50 and LD-C-50 v2 THICKNESS(inches) R-VALUE(°F•ft2'h/Btu) 1 3.7 2 7 3 11 3.5 13 4 14 5 18 5.5 20 6 22 7 25 7.5 27 8 29 9 32 9 5 34 10 36 11.5 41 14 50 20 74 For SI: 1 inch=25 4 mm, 1°F•ft2•h/Btu=0 176 110°K-m2/Vv. 'R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number Town of Queensbury Building &Code Enforcement 1-11 urs 16-101 Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: Sci„ u.r L el n Inspected on: 3— Location: 31 n p 11,o o n Rd I� Arrive: f 5 a.m.I p.m. Permit No.: /4—34,y Inspector's Initials: TYPE OF STRUCTURE: COrv',.t., A if, , • 'Framing-- Y N NIA COMMENTS: Attic Access 22°x 30°minimum I Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers ✓� Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom68 in. Notchtchess//Holes I Bearing Walls r_v/ Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour =Firestopping -Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X — Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing I Firestopping Inspection Report Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: arrd papa pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: J\ IMI NAME: aSstbkOrtiaMi PERMIT#: _ LOCATION: 5\9 Viv'Le'7t" ) INSPECT ON: = A TYPE OF STRUCTURE: (t-c s Framing 7 N N/A COMMENTS: Attic Access 22° x 30' minimum 1! Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge (8) 18D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wail Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:leadirg 8 Codes Forrns-OLD 8ui thing 8 CodeslInspection FonneWraming Firestopping Inspection Repon doc Revised January 7,2008 Rough Plumbing / Insulation Inspection Report —/0 Office No. (518) 761-8256 Date Inspe o est received: I U/ (At/Building & Code Enforcement Arrive: )t)` m/ pmm / 2 742 Bay Road, Queensbury, NY 12804 Inspectot's India L J" NAME: 50, uQrIf I PERMIT#: c / 11--7107 LOCATION: 3 1 0 h I K ev. (2-6 , INSPECT ON: f UZy C/ TYPE OF STRUCTURE: __65,04j--&_— Y N/A Plumbing under slab I j Rough Plumbing /Nail Plates i1 Plumbing Vent/Vents in Place 4 11 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air Air/Heaead 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: ,ffvC,t-<- \it4 i ck ) t c 5Co ci " Rough Plumbing_Insulation Inspection_02 05 13 Town of Queensbury Building & Code Enforcement l)U—«per Office No. (518) 761-8256 � Framing / Firestopping Inspection Report Inspection request r- eived: I l463 Oefv2f 004 Name: L-€C('I ' vlp ( .OGS r c?-04Ins ected on: Location: - 100i bus Arrive: JI /p.m. Permit No.: .. V 4- to Inspector's Initials: TYPE OF STRUCTURE: S C ! ' a_3 Y V NIA raming- COMMENTS: c ccess 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Town of Queensbury Building & Code Enforcement 1 Office No. (518) 761-8256 1 l) — l 2 Framing / Firestopping Inspection Report Inspection request received: (U /2(1/I l Name: Sal V Pn2 '-e I r1 Inspected on: b 2 ( / I Location: 3 ) U n i ( cyv 12--b4i> Arrive: 7 y a.m./p.m. Permit No.: 114 -3 to t Inspector's Initials: TYPE OF STRUCTURE:1 14 44, Y N N/A Framing COMMENTS: Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses ��'�////���ceanrBalte6hi or ld2sson hesfror � (ice and water shield 24 inches from wall (-Ice sepwall 2,3,4 1,2 3 hour �e`v�1 Fire wall 2,3,4 hour �� Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation C� - 1 � `V -L House side'/,inch or 518 inch Type X �� Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Foundation Inspection Report Office No.(518)7614256 Date Inspection request received: Queensbury 74e sbuiy Buildingin &Code Enforcement Arrive: am/pm Dep. . moi/ Y bury,NY 12804 Inspector's Initialst Pm NAME: PERMIT#: L� ♦ -r a LOCATION: " \ C) \)t. INSPECT ON: fr TYPE OF STRUCTURE: c� Ws Comments Footings 1'/ N N/A Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place 1\ Footing Dowels or Keyway in place �>C! Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Cu) /�3 Foundation Inspection Report Office No. ( 8) 761-8256 Date Inspection request received: Queensbury : • , 'ode Enforcement Arrive: am/pm Depart:'0 am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initialsy�[2 L .� NAME: J" r'L0A.0"1^0 PERMIT#: M-3C?5( LOCATION: 3, yV Lb ` hf iA INSPECT ON: /6—Hc/ TYPE OF STRUCTURE: Ce-&, INComments Y N/A Footings �L Piers Monolithic Slab 01 ,a Reinforcement in Place �4. — c2.°171-11 L�� The contractor is responsible for c 7 \�� providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM Rough Plumbing / Insulation Inspection Report Fr'dct 02 y Office No. (518) 761-8256 Date Inspection r• •uest received: Queensbury Building & Code Enforcement Arrive: - 4.1114A a /pm 742 Bay Road, Queensbury, NY 12804 Inspect is . . . NAME: S eir,LPrt c.I n PERMIT#: 3(p LOCATION: 31c l7r,,l R4 INSPECT ON: 9-/9-jy TYPE OF STRUCTURE: 0 A )+, y N N/A Plumbing under slab r (`Rough_,Plumbing/Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test DrainVent Air Air/Heaead f` 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes Insulation /Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 05 13