2014-417 ,, , TOWN OF QUEENSBURY
,1 r41 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20140417 Date Issued: Friday, December 19, 2014
This is to certify that work requested to be done as shown by Permit Number P20140417
has been completed.
Location: 5 BOSS Rd
Tax Map Number: 523400-316-009-0001-003-000-0000
Owner: CHERYL DANIELS
Applicant: CHERYL DANIELS
This structure may be occupied as a:
Garage Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property /
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building& Code nforce t ent
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
FON 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140417 Application Number: A20140417
Tax Map No: 523400-316-009-0001-003-000-0000
Permission is hereby granted to: CHERYL DANIELS
For property located at: 5 BOSS Rd
in the Town of Queensbury,to construct or place
at the above location m accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: CHERYL DANIELS Garage Detached $30,000.00
5 BOSS Rd Total Value $30,000.00
QUEENSBURY NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
SHAWN MCKENNA
518-361-3527
570 WEST Rd
FORT ANN NY 12827-0000
Plans&Specifications
2014-417
Detached Garage 900 sq.ft.
Cross Ref. AV 73-2014 approved 10/22/2014
$135.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, October 28,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o uee bury; les a, , October 28,2014
SIGNED BY ' 4 for the Town of Queensbury.
Director of Building&Cod- Enfo -ment
Town of Queensbury Building & Codes Office Use Only , , A ."1------CAlk \,%
! UOi'�
ACCESSORY STRUCTURE APPLICATION 1R„' a:� n_
Tax Map ID:CC5 .3 1 Lac {-I a 3
A permit must be obtained before beginning construction + \\A\ a •/—/r
Permit,,No: J ry- ✓�
For any structure other than residential principal structure(house)to include,but Permit Fe tOtiV‘Lc cos-aG_'-.-/ .UD fi
not limited to: garage, shed, dock deck, carport, pole barn, greenhouse, etc. Site'P n 6 7�'
Refer to Informational Brochure No.3 Accessory Structures-Sheds/Fences `` -7--,0.Q L1 ptM� /a/01�I/
Date 9t 9 j t i Applicant QkII-14.L.t `\)Cg in\e4c !I
Tax Map ID (lo _ U ct I - 3 Address
R Zoning FRS
Phone _,ree —1G( -CD al
Owner l tR�O w -1C Contractor/Agent Si‘&wit/ MC,k-42 r e
Address c_S-�c3Ss ?tS), Address c- , 't.'-es Rd
CS-t."-iter.Abug-.) ,&i lat i`) f-°r-)- A-."n AlY I76 ? 7
LS
. Phone -11) Ilel-Q�ay Phone S!8 —_Z6/ — 3st ->
Contact Person for Building&Code Commplianc S1�,,..J,J Mc.ke,.,, 4 Day Phone: I cti-3S2 7
Building Street Address: S NSS al/
Subdivision Name: 7 Lot#: Historic Site: Yes No
J
Estimated cost of construction: $ 0 oa d •�
• Are there any other accessory structures on property? If yes,please list: Ala
Type of Construction:
Check all that apply Please indicate measurements as required below
1s+Floor sq.ft. 2^s Floor sq.ft. Total sq.ft. Height
Boathouse
Boathouse with Sundeck
Deck
Detached Garage(#of cars?) 3 v I3/430 gotlgi 9 O O S 5 FT cQa Fr
Dock
Pole Barn
Porch-Open
"Porch-3 season,Covered, Enclosed
Shed
Other Accessory Structure(s)
"Considered floor area&must comply with FAR(Floor area ratio) requirements if located in the Waterfront Residential zone.
w.
Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256
Please include two(2)sets of the following documentation with the application fee:
1. Accessory Structure Application
2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet]
a) Indicate proposed structure,showing setback dimensions from__all surveyed property lines
b) Show location of all existing structures on the property
c) Show location of water supply(well or water lines)
d) Show location and configuration of septic disposal system or sewer line
3. Structural Drawings to include: Floor Plan; Foundation Plan; Cross Sections; Elevations
4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations
with construction costs over$20,000;Any commercial construction
Other Notes:
1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are
necessary].
2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial
application date.
3. Additional Review-All Applications are subject to Zoning Administrator, Code Compliance,and Structural plan review
CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1.1.2011 (INFORMATIONAL)
Residential Building Code
• New driveway requirements for structures located over 300 feet from main road;
• Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas;
• Protection against decay requirements;
• Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; -
• Vent stacks must be 18 inches minimum above roof for all structures
New Electrical Requirements
• Arc fault breakers required in all habitable spaces for receptacles;
• GFI protection for all other receptacles in kitchens, bathrooms, garages,and unfinished basements;
• All receptacles must be tamper resistant;
• Carbon Monoxide detectors must be located within 15 feet of sleeping area;
• All corrugated stainless steel piping must be bonded to the common ground for electrical service
New Enemy Code Requirements
• Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant;
• Programmable thermostats required;
• Lighting must be 50%energy saving light bulbs;
• Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit;
• Res Check inspector's checklist must be available at time of insulation inspection
Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be
performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also
understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to
issuance of a certificate of occupancy.
✓I have read and agree to the above Print Name: 0.31\eQij(. P, J an r PtX
Signature: Usssit. Q
Date: R f a
Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256
Town ofQueerisbury Building &Code Enforcement
Office No. (518) 761-8256
Demolition Inspection Report
Inspection request received:
Name: n 1 a‘ S Inspected on: S—2:3--
Location:
Location: CJS s RC) Arrive: �� i. — a.m. p.m.
Permit No.: / a-cid? Inspector's Initial . iJ7 -
D@ ',no ga 'tia_ge,
Comments am/or diagram
Y N N/A
Gas Shut-off
•
gat-
I�_� '5
tJ�w gQ rc4 cy, ?err.t-i'
Water Shut-off C) lJad / a`1q—/4/
Electric Disconnected
Asbestos Removed/Documentation
Property Cleaned Up and Graded
Okay to Issue Certificate of Compliance
- 1 '3 rti
fror-o-K
Demolition Inspection_11 2012
•
Queensbury Web Map
1
o
3
o a
•
I
. e
N
O ,
m
•
J ,
•
lektil. 1
.
i
QtP
om? >.
N1 \ ,.
"1
, a
It y.
•
•
\ \.. . .
•
c
a
'73 1
•
Map is for GENERAL REFERENCE ONLY. " \ ;1
- - Vil� 372 F-:
•rinted 1/26/2015 1 : 4680 Page 1/ 11
r ;
` Queensbury Building & Code Enforcement - Residenti- Fin. Inspection
Office No. (518) 761-8256 Arrive: 2`- in ar r�, `V-part: 2.2,-,D arNSm/,
Date Inspection request received: Inspector's Initials.t A /� UCC//
NAME PER #: I "/ — /
LOCATION: Ai .B nS.S S DAT /a,_ /9,./tf
TYPE OF STRUCTURE:
Comments:
Yes No N/A S ‘(l ILUD CI M C k(t°n na-
4" Building Number Address visible from road S
Chimney Height/"B'Vent/Direct Vent Location 2 Co II— a a /
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy I trim/doors I main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: _ Every Bedroom: _
Outside every bedroom area: _
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.R-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum 54'Gypsum
asement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/V.hour fire door/door closer 1
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50% / `
Final Survey Plot Plan O V `
Arc Fauft Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding /
As Built Septic System/Sewer Dept. Inspection Sticker t J
Site Plan /Variance required (3( Q('.r- F-Rt,c JV
d [ KkhPECT
Okay to issue C/C or C/0[Temporary/Permanent]
LABuilding&Codes Forms\Building&Codesllnspection Fonns\Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08;Revised 12/22110,Revised 04/13/11
glip:,,) <(4-as
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: 1`-9Ca d��y - - ' �,°fj 72 am•
Date Inspection request received: Inspector's Initials:
7
NAME: — ( . fl telt "E' • IT#. I'u-9;
LOCATION: , fj,C S &eti 3 • E / a -/co/y
TYPE OF STRUCTURE: & rra.q e
JJ Comments:
Yes No N/A_
4" Building Number Address visible from road n
Chimney Height/'B'Vent/Direct Vent Location 3 (01_3 5a / S'eaup fl
Fresh Air(Make iKer,nc ,
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
-
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more }�• _ f
Guard at deck,porches 36 inches or more
C.4
Handrail Termination at Newell Post or Wall _
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant /
Grade away from foundation 6 inches with 10 feet J
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: _ Every Bedroom:
Outside every bedroom area _
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area _
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window .
Plumbing fixtures .
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification _
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 31)feet or within fine of site re
Oil Furnace shutoff at entrance to furnace area Fumace/Hot Water Heater operating t - rLow water shutoff boilere �C`
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Jj :
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
-FI xBuilt GasSeptic Pipe Bonding /
System/Sewer Dept. Inspection Sticker
IN Site Plan /Variance required
Flood Plain Certification,if required,--- -- J
J Okay to issue C1 C or C t0[.temporary LP_ennanent]i
L:1Building&Codes Forms1Building&Codesllnspection FonnslResidential Final Inspection Form_revised_100405.doc; Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11
Town of Queensbury Building & Code Enforcement
Office No. (518)761-8256
Framing I Firestopping Inspection Report
Inspection request received:
Name: Inspected on: "Ate
Location: QC). Rce Q Arrive: a.m. 120
Permit No.: —L\ \-1 Inspector's Initials: •�
TYPE OF STRUCTURE: Ge RAGE_
Y N NIA COMMENTS:
Framing `-'R�2-71 t
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided �
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly ✓/
12"D.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in. ,
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1r Yt sw)to pi6 gauge 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center (t DO -rhllo iDE 6`oD
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour Ce 0C-R- R.1^
Fire wall 2,3,4 hour n 7� �T*c
Firestopping LO \ EVE__ 11603C-H 6g_ BOLTS
Penetration sealed \R-E 'NA S3
16 inch insulation in cavity min. 1�
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X REcHEck F S ►J Pit
Ceiling/wall 1 CV`OO
Windows Habitable Space/Bedrooms 6YEby
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/ Firestopping Inspection Report
J hors /b-I a
Foundation Inspection Report a\)
Office No. (518) 761-8256 Date Inspectionrrequest ed:
!
Queensbury Building &Code Enforcement Arrive: V-40 a,Y i:part: `I arr
742 Bay Rd., Queensbury, NY 12804 Inspector's Initial
NAME: no t° t, s PSE' IT#: 1
LOCATION: 5 B bS;S Rol INSPECT ON: 1' 3' 'Fl Y
TYPE OF STRUCTURE: 50.A61....54/2-
Comments
Y N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R -
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM
r
4 11 ['''—, 1.1"::1:17:-.
1 - ,.
9)147_
' .4.,,. ,,,, F- •
36)-- 0--)t-- -
6 i i
RECE EL) i t Lot
...
. anDsoi,
/417 1 ixi t (014/611/LeG
0 ,
Ogg
...,
71.7,
OCT 2 ,7- 011i ,
•••• .. .
. •„„, :-... - ii.
TOWN OF QUEENSBUR
ZONING OFFICE V, cFP
Ii E5g; tot.
1
r;
I .—
ill la
. It
I ------- i rzi
I —
otopr
5 11 i
, oril. --•
_.......
k 1----
I
_
----- ..,
—__
___
• i "'
\ I
oth
i •...._
i I
, .
c f
\ \
t
---____
li
il •
, : a 1.•e 13
elii
1 1 4!
i ...,• .„.,...,s.
, •
-.....,\__..,....
I i 0 0.119•CV•
162.11•
t
1
1 .
ti
I .
t• - •
'I g li.5. • ..
\ 5
_
,
h
I. \ .•
i
, •
tt
-t 1
',..i 1
;4 •
t
\ • ' :.t
1'' ...k? 1 ;• .
.i •
‘1
1 .
1 1 '
—_—_--_ .---
',.
I tip .
- :
11 . sic BAN "I‘D
..------
Proposed Subdivision Modification-
i! .i ocrx. Du.s ez.2
1 1
i I ir ik Steves 4`. •..':. 75.-7=7.,-.7.4:-:=_-
.— ; Land Surveyors , VI i F.F.:I,-..-F.r-41-2 ET-.-:.7 Cheryl Daniels
,- ,-, -,4 7.7•=7.......==..169 116011.4 6464 Oostan110.1161.Yea MU )
.. , ===.t..,
1 (610 111-11174 /iYea cy U..Ne. 60115 744 1 11/13/. SLIMISIDN 1.01......—
Til WV 1212141001
316.09-1-9