Loading...
2014-433 TOWN OF QUEENSBURY Fom 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140433 Date Issued: Wednesday, December 03, 2014 This is to certify that work requested to be done as shown by Permit Number P20140433 has been completed. Location: 7 PHILLIPS Ave Tax Map Number: 523400-303-020-0001-044-000-0000 Owner: CARL MATTISON Applicant: CARL MATTISON This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property GG�66��'' Tc�7y\l jail owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140433 Application Number: A20140433 Tax Map No: 523400-303-020-0001-044-000-0000 Permission is hereby granted to: CARL MATTISON For property located at: 7 PHILLIPS Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CARL MATTISON 7 PHILLIPS Ave Residential Addition $9,200.00 QUEENSBURY,NY 12804-0000 Total varve $9,200.00 Contractor or Builder's Name/Address Electrical Inspection Agency VOLINO. ANTHONY J. SR. Plans&Specifications 2014-433 Res. Addition 441 Sq ft $100.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, September 23,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town.of Queue nsbur 41 Tu September 23,2014 SIGNED BY c //J)a%✓P i j for the Town of Queensbury. Director of Building&Code En • cement PRINCIPAL STRUCTUR APPLICATION ; 1.1. ' \ Office Uset Only DATE 161 i g �\\ 1 rL t �1 if � Received 3 � •t �c`t' 1 G 2�Permit NIoax Map D / • I - �� g - TAX MAP ID �� p 3 . 0�0' �� �, �I .I t A y ►t�-� „.. 't P mit/Fee • 'a .. ZONING TOg ILDtNG&C CRec=Fee Site Plan# HISTORIC SITE Yes No Subdivision # SUBDIVISION NAME Lot# TOWN BD.RESOLUTION 8E-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWEWNGS,DUPLSCES OR TWO FAMILY DWELUNGS, MULTIPLE FAMILY DWELUNGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT I/JI ALJA 4 + . r OWNER / n5 ADDRESS ta ADDRESS I JII r t.I/r/ � PHONE/E-MAIL +\ !.1 it /, i AO ' lr . I / • PHONE/E-MAIL t CONTRACTOR i I••�( (',, l/��n�,I M��1d COST OF CONSTRUCTION ESTIMATED : $ fLCJ ADDRESS: l �V iliret`1�/lse eti 7ke' 'UILDINGADDRESS: 7 }/I/i;) )1; PHONE/E-MAIL `5 3W-1 (.1Th CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: �/ PHONE TYPE OF CONSTRUCTION Check alt that apply • Please indicate measurements as required below New Addition Alteration 1st floor sq. ft. 2nd floor sq.ft. Total sq.ft. Height Single Family • - F- . Two-Family Multi-Family (#of units ) Townhouse Business Office Retail - Mercantile Factory- Industrial Attached Garage (#of ) Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business Proposed use of building or addition A,�,I; I Source of heat (circle one) • Gas it Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? j Site Information a. Dimensions or acreage of lot u__1 -1 b. Is this a corner lot? Nth c. Will the grade be changed as a result of construction _Yes V No d. Public water or Private well P ,, C, c e. Sewer or Private Septic System ,�eqt/ Value of all work to be performed (labor or materials) $ 011a-00 th •owe y. DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/ description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate . occu ancy. I have read and agree to the above: PRINT NAME: es L 1( 0 DATE � SIGNATURE: �/�_ "at, A .,/. .l DATE q FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 ue s /04: Foundation Inspection Report Office No. (518) 761-8256 Date Inspection r ; .. Queensbury Building&Code Enforcement Arrive: -; � ,Depart: , 742 Bay Rd., Queensbury, NY 12804 \ Inspector's- Ini is s: NAME: ('(1 g0 /}a I Q iti �l IT#: / -/ '17-3 LOCATION: 7 1 '11 y r l P INSPECT ON: \\ -755 -19 TYPE OF STRUCTURE: 2A) Ad dl Comments `f9 Y N N/A Footings Piers 4% SFt%ic-2 0 .� Monolithic Slab ��� Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Ct�� Materials for this purpose on site. C/ r, ° Rl.O.{'c! hD Foundation/Wallpour Reinforcement in Place 1O,) � Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM wi Rough Plumbing / Insulation Inspection • port � a Office No. (518) 761-8256 Date Inspection.aq st r;ce' I \-lam Queensbury Building & Code Enforcement Arrive: 'Aril,. am r r 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: a,— / tit NAME: (\®-v , sen PERMIT#: LOCATION: `� FL j [(I' S INSPECT 0 ' _ m / '// TYPE OF STRUCTURE: PtE.S IT,10- 3/--c1 OM Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/ Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test -- - - Water Supply Piping Air/Head 50 P.S.I. for for 15 minutes slrfa-ion Sidential Check/Commercial Check c7i ss Window Sealing 2Fc"aoQ Tyvek or Similar Exterior Sealant C FL� Proper Vent, Attic Vent Door/Window Sealed (No Insulation) V — '� LOM.1-1? Duct/Hot Water Piping Insulation V--_3S If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape ® '-51--V*L\N4 Blower Door Test Air Sealing COMMENTS: Rough Plumhing_Insulation Inspection_02 0513 Town of Queensbury Building & Code Enforcement / meg (9-1/ Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: ,, LL Name: m0-44.6—So !1 Inspected on: /.o Location: tJ fl J flips Arrive: �� a.I, p. J' Permit No.: i— y.3 3Inspector's Initials: / TYPE OF STRUCTURE: Fs Add Y N NIA COMMENTS: Attic ss 22"x 30°minimum � � Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers i� _ Jack Posts/Main Beams e, � Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches!Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 160 nails each side .11 stopping 1,000.ores. t.floor trusses • i..11 or Bolts 6 ft. less on center _ ctand wat shield inches frgm'waft Fir eparation 1,2,3 hour F e' all 2,3,4 hour estopp> Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space!Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above!below grade 5.0 sf grade Design Professional Sign-off, if required Framing / Firestopping Inspection Report "Z..= OCD Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reque -: i t Queensbury Building &Code Enforcement Arrive: %<fO a 'l11'�/ epart: am n J 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial �i / PA — ` _ NAME: 1'14;1"1-11)043 PERMIT#: , LOCATION: 7 'P NA tt L R5 R.,\F INSPECT ON: 01 —7 i4— 1 Lir TYPE OF STRUCTURE: ECi1 Icia Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing ? for 48 hours following the placement 9 �. of the concrete. Materials for this purpose on site. (_Foundation/Wallpour tkstht Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6;:zacIctill 6 mil poly for wet areas under slab Approval I Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM Olt \Z . Foundation Inspection Report Office No. (518) 761-8256 Date Ins ection request received: Queensbury Building&Code Enforcement Arrive: 0 Depart: ]J= tt 742 Bay Rd., Queensbury,@NAY X12804 Inspector's Initia s: SO \— NAME: Make-l.ppt.\ PERMIT#: [� LOCATION: f )- tl( s J • INSPECT ON: p TYPE OF STRUCTURE: 1—ZIP Lk- Comments Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement ofthe concrete. Materials for this purpose on site. Foundation/Wallpour .0 ESQ_ _�� laECt\V--,1 Reinforcement in Place , 1 \V--V Dowels or Keyway in place @_ Z_O�� a Foundation Dampproofing Foundation Waterproofmg Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM ithp&del 'pmm Foundation Inspection Reporter cA-Vlei--kE t�IN , Vek- w Ic_.?-e\-er Office No. (518) 761-8256 Date Inspgio e 1 ue ci Z=th �' e Queensbury Building&Code Enforcement Arrive: Atps.:J.� �tiepart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: c if NAME: M Ott l.o, PERMIT#: /#</`—'4133 `4f33 LOCATION: "7 Ph ,v1 1 ► . INSPECT ON: CI—7)419 TYPE OF STRUCTURE: i - / . 74,44 Comments Y j N N/A ;\ Footings �V/ Piers Monolithic Slab Reinforcement in Place Y/ The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM