RC-000746-2016 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804.5904 (518)761-8201
at Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000746-2016 Date Issued: Friday, April 14, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000746-2016
has been completed.
Tax Map Number: 301.15-I-61
Location: 27 ELK RIDGE DR
Owner: FOOTHILLS BUILDERS,LLC
Applicant: FOOTHILLS BUILDERS,LLC
This structure may be occupied as a: Single-Family Dwelling 1,840 sq. ft. and
gas stove to be installed in 3-season room By Order of Town Board
Garage 506.74 TOWNOF QUEENSSBURAY
Issuance of this Certificate of Occupancy DOES NOT relieve the \ /^(((iiivyyllittt"' VVV) - (/ k�—
property owner of the responsibility for compliance with Site Plan, ttt�� //
Variance,or other issues and conditions as a result of approvals by the
Director of Building a@ Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
Qmw 742 Bay Road.Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000746-2016
Tax Map No: 301.15-1-61
Permission is hereby granted to: FOOTHILLS BUILDERS,LLC
For property located at: 27 ELK RIDGE DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: FOOTHILLS BUILDERS,LLC Single Family-New $200,000.00
Owner Address: 9 Mountainside DR Total Value $200,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
FOOTHILLS BUILDERS,LLC
9 Mountainside DR
Queensbury,NY 12804
Plans&Specifications
Single-Family Dwelling 1,840 sq.1t.
Garage 506.74
$1,29401 PERMIT FEE PAID-T16S PERMIT EXPIRES: Wednesday,November 15,2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before thjexpir i.ondd/ate.)
Dated at the Town of eensbu �'(�esd mber 15,2016
SIGNED BY: ,a for the Town of Queensbury.
Director of Building&Code Enforcement
PRINCIPAL STRUCTURE APPLICATION Office Use Only
Date:
Permit No.
Tax Map ID Permit Fee LC- 2:3 6 2-2 I b
Zone Historic? _Yes No Rec Fee °65i —
Subdivision Name Lot# Site Plan#
Project Location
J 4t Z�- Subdivision# 1rtVOtlR� 1205
J
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit feels).
Primary Owners)
Address
" I�l,U'1 r2lt 1'1 ' C1tt., v�'• 1'1 �t�
Phone/Email
Applicant
Address
Phone/Email
� t
Contractor 1U Utl
Address BUILDING 8 COMES
Phone/Email
Contact Person for Building& Codes Compliance: LCUC i Phone lcl
TYPE Or CONSTRUCTION
,/Check all that apply New Addition Alteration 1"floor sf 2"d floor sf Total sf Height
Single Family V/
Two-Family
Multi-Family
(#of units
Townhouse
Business Office
Retail-Mercantile
Factory-Industrial
Attached Garage
(1, 2, 3, 4+) Ifo ,
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business
Proposed use of building or addition ....... 2 z s , C\C ,l
Source of Heat(circle one) Gas) Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances & Chimneys
Are there structures not shown on plot plan?
Are there easements on the property?
Site Information:
a. Dimensions or acreage of lot
b. Is this a comer lot? Yes _No
c. Will the grade be changed as a result of construction TYes _No
d. Public water or Private well (circle one) Private
e. Sewer or Private Septic System (circle one) Sewer Private
Value of all work to be performed(labor or materials) $ &6'4 7Zo,o0
DECLARATION.•
I. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes, local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: M Q.r i L-&_ DATE: 10 Q G - I
SIGNATURE: DATE: /0- Q & - 1 to
For office use only
Operating Permit Issued: _Yes —No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Town of Queensbury Thomas R. Van Ness
Highway Department Highway Superintendent
742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929
Phone: 518-761-8211
Fax: 518-745-4466 David Duell
Deputy Highway Superintendent
Home: 518-745-0938
DRIVEWAY PERMIT
Date:
Applicant Name: t�l vs f/o
Telephone No.: u
Address to be Inspected Z1-6\�-- '\fid -, LQ-r OCT 26
Return Address:
S DFQUEENSS
ING& CODES
Applicant must show exact location and width of driveway(s) to be connected to the tg lacing stakes
at the specified location
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action
has been taken:
STEP 1: ( ) Preliminary approval
NEED ( ) Slight Swale
( ) Deep Swale
O Level with the road
( ) Level with the top of the paved wing
Size culvert pipe to be used(if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36"
Preliminary inspection completed by: Date:
Approval by Highway Supt.: or Deputy Supt.:
Upon completion please resubmit this approval permit for a final approval.
STEP 2: ( ) Final Approval ( ) Rejected
Date:
Thomas R. Van Ness, Highway Superintendent David Duell,Deputy Highway Superintendent
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
SEPTIC DISPOSAL APPLICATION Office Use Only
Received
DATE: Tax Map ID
TAx MAP 1D: Permit No. P -:, q4(D 20 t to
Permit Fee
ZONE:
APPLICANT ,� 1j� 1��e\,S PHONE/E-MAIL
ADDRESS
INSTALLER/ PHONE/E-MAIL
BUILDER
OWNER
ADDRESS
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE:
PHONE/E-MAIL U,
143 '4 UIR
RESIDENCE INFORMATIONVWJN FOUFFNSBURY
Year Built #of bedrooms X gallons per bedroom =total Daily flowBUILDING& CODES
1980 or older Garbage grinder installed Yes No
1981.1991 Spa or Hot Tub installed _Yes _jNo
1992-Present
PARCEL INFORMATION
Topography Flat rolling _Steep slope _%Slope
Soil Nature Sand _Loam _Clay _Other
Groundwater At what depth: 1},�
Bedrock/Impervious material At what depth: N Ft
Domestic Water Supply 1' Municipal _Well(if well,water supply from any septic system absorption is_ft.)
Percolation Test Rate: I—) per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION
Tank size IMO gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub
System Absorption field with 42 stone Total length�_R.;Each Trench a-7)
Seepage Pit with#3 stone How many: ;Size
Alternative System Bed or other type:
Holding Tank System Total required capacity? Tank size #of tanks
Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will
no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the
septic system layout on file—no exceptions.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure
to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to
abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
PRINT NAME: (V( DATE: 10104, i
SIGNATURE: DATE:
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
REScheck Software Version 4.6.2
Compliance Certificate
Project Lieberman Ranch
Energy Code: 2015 IECC
Location: Warren County, New York
Construction Type: Single-family
Project Type: New Construction 301 .15-1 -61 RC 746-2016
Conditioned Floor Area: 1,840 ft2 Foothills Builders
Glazing Area 17% Lot 11, House No. 27 Elk Ridge Drive
Climate Zone: 6 (8499 HDD) $FD w/ garage
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
FHB Lot 11 VISION Engineering, LLC
Queensbury, NY 12804 206 Glen Street
Suite 56
Glens Falls, NY 12801
�ompliance: Passes using UA tra'dL-off
Compliance: 0.7%Better Than Code Maximum ILA: 275 Your ILA: 273
The%Better or Worse Than Code Index reflects how close to compliance the house is based an code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cant.
Assembly or U-Factor ILIA
Ceiling 1: Raised or Energy Truss 1,840 38.0 0.0 0.025 46
Wall 1: Wood Frame, 16" o.c. 1,504 21.0 0.0 0.057 70
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 131 0.300 39
Door 1: Solid rEOSBURY N] E - 20 0.250 5
Door 2: Glass `J 53 0.300 16
Door 3: Glassq C 53 0.300 16
Door 4: Solid LO1U20 0.140 3
Wall 2:Wood Frame, 16" o.c N70 21.0 0.0 0.057 3
Door 5: Solid CDES 20 0.200 a
Basement Wall 1: Solid Concrete or Masonry 1,390 0.0 15.0 0.046 63
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth: 7.8'
Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.340 3
Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 17 0.290 5
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 1 of 10
Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirem is listed in the REScheck Inspection Checklist.
r
Name-Tifls 151ghsture Dat
O
w. gy�yp9
fn
n
s�OA tio. 07906
R�Fc I NP
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 2 of 10
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Re .ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance forthe
0 building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1. Construction drawings and ❑Complies
103.2, documentation demonstrate - ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. []Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: :❑Complies
403.7 sized per ACCA Manual S based Btu/hr_ Btu/hr ❑Does Not
[PR2]' on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual J or other methods Btu/hr_ Btu/hr
approved by the code official. �❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) RAMedium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 3 of 10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R-_ R-_ ❑Complies See the Envelope Assemblies
[1`04)1 insulation R-value.Where interior R R- ❑Does Not table for values,
4 , insulation is used,verification j❑Not Observable
'.,may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall [ Complies
[F0511 insulation installed per El Does Not
!manufacturer's instructions. ❑Not Observable
❑Not Applicable j
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06)1 .insulation depth of burial or ❑Does Not ;table For values.
(distance from top of wall. ;❑Not Observable
[]Not Applicable
sA protective covering is installed ❑Complies
17� to protect exposed exterior ❑Does Not
'I insulation and extends a ❑Not Observable I
minimum of 6 in. below grade.
❑Not Applicable j
403.9 Snow-and ice-melting system ❑Complies i
[FO12]2 'controls installed. ❑Does Not
J ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
-----------
11 High Impact(Tier 1) Medium Impact(Tier 2) ; Low Impact(Tier 3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 4 of 10
Section Pians Vered Field Vered
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies ;See the Envelope Assemblies
402.3.4 ❑Does Not :table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, .Glazing U-factor(area-weighted : U-_ U-_ ❑Complies See the Envelope assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Nat Observable
402.5 ❑Not Applicable
[FR21'
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table. ❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable
❑Not Applicable
1402.4.3 'Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish j❑Does Not
and labeled to indicate <_2.0 cfm []Not Observable
leakage at 75 Pa. '❑Not Applicable
403.2.1 Supply and return ducts in attics '[]Complies
TR1211 insulated >=R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_ ❑Not Observable
R-6 where< 3 inches.Supply and
return ducts in other portions of ❑Not Applicable j
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR1513 ducts or plenums. ❑Does Not
!+i ❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 OF or chilled fluids ❑Does Not
below 55 OF are insulated to >_R- ❑Not Observable
3' ❑Not Applicable
403.4.1 Protection of insulation on HVAC '-'❑Complies
[FR2411 piping. ❑Does Not
❑Not Observable ;
]Not Applicable j
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 ->R-3. ❑Does Not
01 ❑Not Observable I
❑Not Applicable j
403.6 Automatic or gravity dampers are ❑Complies
[FR191= installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Nat Applicable j
1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier3)
Project Title: Lieberman Ranch Report date: 1026/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 5 of 10
Additional Comments/Assumptions:
1 I High Impact(Tier 1) ',2 1 Medium Impact(Tier 2) %' ;';; Low Impact(Tier 3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 6 of 10
Section Plans Verified Field Verified
# insulation Inspection Complies? Comments/Assumptions
V& Re IDalue Value
303.1 .All installed insulation is labeled ❑Complies
[IN1312 or the installed R-values - -❑Does Not
„provided. ❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 'wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN311 exterior,the exterior insulation
requirement applies (FR10). ❑ Steel ❑ Steel ;❑Not Applicable j
303.2 ;Wall insulation is installed per ❑Complies
[IN411 :manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 7 of10
Section Plans Verified Field Verified
# I Final inspection Provisions Value Value Complies? Comments/Assumptions
AReq.ID _
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, E] Wood ❑ Wood ❑Does Not table for values.
402.2.2• ❑ Steel ❑ Steel
402.2.6 ❑Nat Observable
[Fill' ❑Not Applicable
303.1.1.1, :Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI211 :Blown insulation marked every
300 ft'. ❑Not Observable
❑Not Applicable
Vented attics with air permeable ❑Complies
insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
...,.;❑Not Applicable
r2i24Attic access hatch and door R-_ R-_ ❑Complies
insulation aR-value of the ❑Does Not
adjacent assembly. j❑Not Observable
❑Not Applicable j
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ I❑Complies
[FI17]1 ;ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. j❑Not Observable
❑Not Applicable
403.2.3 :Duct tightness test result of<=4 : cfm/100 cfm/100 ;❑Complies
[FI4I1 ;cfm/100 ft2 across the system or ft2 ff ❑Does Not
,<=3 cfm/100 ft2 without air ❑Not Observable
:handler @ 25 Pa. For rough-in
bests,verification may need to ❑Not Applicable
.occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F]2711 :determine air leakage with : ft2 ft2 ❑Does Not
;either: Rough-in test:Total
'leakage measured with a ;❑Not Observable
pressure differential of 0.1 inch ❑Nat Applicable
;w.g.across the system including
'the manufacturer's air handler
enclosure if installed at time of
.test.Postconstruction test:Total
:leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
;including the manufacturer's air ,
:handier enclosure.
403.3.2.1 :Air handler leakage designated ❑Complies
[F124]1 .by manufacturer at<=2%of _ ❑Does Not
;design airflow. ❑Not Observable
_ ❑Not Applicable j
Programmable thermostats `^❑Complies
installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ..,I❑No[Applicable
Heat pump thermostat installed [ Complies
on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
Circulating service hot water ❑Complies
systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
- ❑Not Applicable
1 lHigh Impact(Tier 1) 2 Medium Impact (Tier 2) � 3JLow Impact(Tier 3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 8 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
& Req.10 Value .___—. Value_
x403.6.1 All mechanical ventilation system ❑Complies
[F12512 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
------ — ---------------
403.2 Hot water boilers supplying heat ❑Complies
(F12612 through one-or two-pipe heating El Does Not
systems have outdoor setback ❑Not Observable
control to lower boiler water
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]' have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- :❑Not Applicable
'syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F12912 comply with IEEE 515.1 or UL ,❑Does Not
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the ❑Not Applicable j
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F. _
403.5.4 Drain water heat recovery units ❑Complies
[F13112 tested in accordance with CSA ❑Does Not
B55.1.Potable water-side ❑Not Observable
pressure loss of drain water heat
recovery units<3 psi for ❑Not Applicable j
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units <2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
(F1611 'fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. ❑Not Observable I
Does not apply to low-voltage
lighting.
EI Applicable j
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
'.., ❑Not Observable
❑Not Applicable j
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 pact(Tier Low Im3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 9 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies?. Comments/Assumptions
Req.lD_ --_
401.3 'Compliance certificate posted. ❑Complies
[F[7)2 ❑Does Not
❑Not Observable
❑Not Applicable j
303.3 Manufacturer manuals for ❑Complies
[1`I18)' mechanical and water heating ❑Does Not
j systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) - Medium Impact(Tier 2) 3 1 Low Impact(Tier3)
Project Title: Lieberman Ranch Report date: 10/26/16
Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 10 of10
�( 2015 IECC Energy
j Efficiency Certificate
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.30
Door 0.30
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
Item#:403787
Specification
Date: B-06-1
..', .v.4a ...a L.t
SHR 1504 r �;
NOV 0 7 2016 SP" vi
u5
Heat Recovery Ventilator
Product#: 40072 _ ' �c%�E5
-�:,.:_ _
Fans
Two(2)factory-balanced fans with backward curved blades.Motors come
with permanently lubricated,sealed ball-bearings to guarantee long life
o and maintenance-free operation.
Heat Recovery Core
Aluminum heat recovery core covered by a limited lifetime warranty. Core
dimensions are 9"x 9"(229 x 229 mml with a 15"(380 mm)depth.Our
heat exchangers are designed and manufactured to withstand extreme
temperature variations.
Defrost
A preset defrost sequence is activated at an outdoor air temperature of
23'F 1-5°C)and lower.During the defrost sequence,the supply blower
Fantech's side port connection HRV for budget conscious house projects, shuts down&the exhaust blower switches into high speed to maximize
the SHR 1504 unit brings a continuous supply of fresh air into a home the effectiveness of the defrost strategy.The unit then returns to normal
while exhausting an equal amount of contaminated air. During winter, operation,and continues cycle.
fresh incoming air is tempered by the heat that is transferred from the
outgoing air so you save on energy costs,while during summer,the Serviceability
incoming air is pre-cooled if the house is equipped with an air cooling Core,filters,fans and drain pan can be easily accessed through latched
system.The SHR 1504 is equipped with automatic defrost mechanisms door.Core conveniently slides out on our new easy glide core guides. 17'
so you can use your HRV all year long. (432 mm)of clearance is recommended for removal of core.
Features Case
• Compact design 24 gauge galvanized steel.Baked powder coated paint.
• Fans with backward curved RadiCAL blade Insulation
• Electrostatic filters(washable) Cabinet is fully insulated with 1" 125 mm]high density expanded
• Aluminum heat recovery core polystyrene.
• External screw type dry contacts
• Easy Core Guide Channels For Removing Core Filters
• Only weighs 45 lbs (20Kg) Two(2)washable electrostatic panel type air filters 8.5"(216mml x 15"
(380mm]x 0.125"13mml.
Optional Controls
• ECO-TouchTM(944929) — Programmable Touch Screen Wall Control Controls
• EDF7 (944eea( — Electronic multi-function dehumidistat External three(3)position(Low/Stand By/Medium)rocker switch that will
• RTS3 (940376) — 20/40/60 minute over-ride offer continuous ventilation. Fentech offers a variety of external controls.
• RTS2 (940164( — 20 minute over-ride [see controls)
• MDEH1 (940172) — Oehumidistat Installation
Specifications Unit is typically hung by using installation kit supplied with unit.Mounting
• Duct size — 6"If 52 mm) bolts provided on top four(4)corners of unit.
• Voltage/Phase — 120/1 Warranty
• Power rated — 156 W Limited lifetime on aluminum core,7 year on motors,and 5 year on
• Amp — 1.3 A
parts.
• Average airflow — 149 cfm(70 Us)
®0.4'Ps(100Pa1
•��'' fantech
•" a systemair company
Dimensions&Airflow r
fresh air
to inside
E fresh air
from outside
stale air
® from inside
I0 stale air
A�,„4. e c F� o to outside
®®®®®®®®®®
6HR1504 21/4 57 231/2 597 25/8 67 173/8 441 161/8 410
Clearance of 17'1432 mm)in front of the unit Is recommended for removal of core.All units feature three foot
plug in power cord with 3-prong plug.
Ventilation Performance
Airflow((1s1
i 1.2 24 47 71 94300
'dExhaust
Net supply airflow 170 1801 149(70) 128 1601 104 1491 77(36) 49(23) 6 1.0 250
E3
Gross supply airsmr 174(B2) 1511711 130(61) 186(50) 79(371 50(24) s 0.6 200
Gross exhaust airflow 1691791 146(6B) 1251591 1001471 751351 46(22 ,', 0.6 150
2 a
0.4 100
9
e
0.2 50
0.0 0
0 50 100 750 200
Airflow fchnl
Energy performance
32 0 67 31 72 60 73 -0.11
32 0 109 51 98 59 70 0.00
32 0 161 76 144 55 B3 0.00
-13 -25 a8 32 73 56 77 -0.02
Requirements and standards
• Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators
• Technical data was obtained from published results of test relating to CSA C439 Standards
• HVI certified
Contacts Distributed by:
Submitted bv: Date:
Quantity: Model: Proiect#:
Comments:
Location:
Architect:
Engineer: Contractor:
United states 10048 Industrial Blvd.•Lenexa,K3 66215•1.600.747.1762•www.fentech.net
Canada 50 KanalAakt Way•Bouctouche,NB E48 3M5•1.800.5653546•www.fantech.net
Fantech,reserves the right to modify,at any time and without notice,any or all of its products'features,designs, •••' f a n t e c h
components and specifications to maintain their technological leadership position. :��..�1:
a systemair company
F. W. WEBB COMPANY RESIDENTIAL HEAT LOSS/GAIN CALCULATIONS
PREPARED BY SCOTT LANGEWORTHY BR16
PROJECT # : 215118 BY SLL ENTERED 11/04/16 BLDG
1. NAME :CERRONE GAIN BTU: 29390
2. LOCATION :LIEBERMAN GAIN CMF: 981
3. HI DESIGN TMP: 91 8.GRND TEMP 50 LOSS BTU: 75626
4. LO DESIGN TMP: -20 9.COOL AIR TMP: 50 LOSS CFM: 1429
S. ROOM TEMP 71 10.WARM AIR TMP: 120 BASEBRD' : 135
6. LEEWAY 10 TONNAGE 2 .4
7. # OF PEOPLE 5@400
-------------------------------------------------------------------------------
ROOM # 1 OF 11 41.WALL G DELTA 20
12.ROOM NAME :BATH MASTER 42.WALL L DELTA 91
43 .FLOOR G DELTA : 20
44.FLOOR L DELTA : 91
45.CEILNG G DLTA : 20
46.CEILNG L DLTA : 91
47.BELW GRD DLTA : 21
35.MISC BTU GAIN :
13.EXT WALL LEN : 17 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS :
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 6 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 956 27390
20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 32 914
21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 2781 75626
22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 53 1429
23 .FLOOR SQ FT 85 34.BATH(Y*N) Y * BASEBRD' : 5 135
-------------------------------------------------------------------------------
ROOM # 2 OF 11 41.WALL G DELTA 20
12.ROOM NAME :LAUNDRY10 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13.EXT WALL LEN : 10 24 .FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 318 27390
20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 11 914
21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 1177 75626
22.W BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 22 1429
23.FLOOR SQ FT 50 34.BATH(Y*N) N * BASEBRD' : 3 135
-------------------------------------------------------------------------------
NAV
:s NR,
ROOM # 3 OF 11 41.WALL G DELTA 20
12.ROOM NAME :MUD 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13.EXT WALL LEN 5 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 21 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 523 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 17 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 2058 75626
22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 39 1429
23 .FLOOR SQ FT 60 34.BATH(Y*N) N * BASEBRD' : 4 135
-------------------------------------------------------------------------------
ROOM # 4 OF 11 41.WALL G DELTA 20
12.ROOM NAME :WIC 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13.EXT WALL LEN : 0 24 .FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 14 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 158 27390
20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 5 914
21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 529 75626
22.% BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 10 1429
23 .FLOOR SQ FT 35 34.BATH(Y*N) N * BASEBRD' : 1 135
--------------------------------------------------------------' --------
ROOM # 5 OF 11 41.WALL G DELTA 20
12.ROOM NAME :MASTER 42.WALL L DELTA 91
43 .FLOOR G DELTA : 20
44.FLOOR L DELTA : 91
45.CEILNG G DLTA : 20
46.CEILNG L DLTA : 91
47.BELW GRD DLTA : 21
35.MISC BTU GAIN :
13.EXT WALL LEN 35 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS :
14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 42 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 2061 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 69 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 7798 75626
22.$ BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 147 1429
23.FLOOR SQ FT 294 34.BATH(Y*N) N * BASEBRD' : 14 135
-------------------------------------------------------------------------------
ROOM # 6 OF 11 41.WALL G DELTA 20
12.ROOM NAME :KITCHEN / DINNETT 42.WALL L DELTA 91
43.FLOOR G DELTA : 20
44.FLOOR L DELTA : 91
45.CEILNG G DLTA : 20
46.CEILNG L DLTA : 91
47.BELW GRD DLTA : 21
35.MISC BTU GAIN
13 .EXT WALL LEN : 22 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT 9 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 42 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 4079 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 136 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 7272 75626
22.$ BELOW GRADE: 0 33 .KITCHEN(Y/N) Y * LOSS CFM: 137 1429
23.FLOOR SQ FT 264 34.BATH(Y*N) N * BASEBRD' : 13 135
------------------------------------------------------------------------------
ROOM # 7 OF 11 41.WALL G DELTA 20
12.ROOM NAME :BED 2 42.WALL L DELTA 91
43 .FLOOR G DELTA : 20
44.FLOOR L DELTA : 91
45.CEILNG G DLTA : 20
46.CEILNG L DLTA : 91
47.BELW GRD DLTA : 21
35.MISC BTU GAIN :
13.EXT WALL LEN 26 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS :
14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT 30 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 3052 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 102 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 5142 75626
22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 97 1429
23.FLOOR SQ FT 163 34.BATH(Y*N) N * BASEBRD' : 9 135
-------------------------------------------------------------------------------
ROOM # 6 OF 11 41.WALL G DELTA 20
12.ROOM NAME :BATH 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13.EXT WALL LEN : 8 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 9 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 1130 27390
20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 38 914
21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 2715 75626
22.% BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CEM: 51 1429
23.FLOOR SQ FT 96 34.BATH(Y*N) Y * BASEBRD' : 5 135
-------------------------------------------------------------------------------
ROOM # 9 OF 11 41.WALL G DELTA 20
12.ROOM NAME :CIGAR 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13.EXT WALL LEN 27 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT 30 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 2949 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 98 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 4807 75626
22.4 BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 91 1429
23.FLOOR SQ FT 138 34.BATH(Y*N) N * BASEBRD' : 9 135
-------------------------------------------------------------------------------
ROOM # 10 OF 11 41.WALL G DELTA 20
12.ROOM NAME :GREAT 42.WALL L DELTA 91
43.FLOOR G DELTA 20
44.FLOOR L DELTA 91
45.CEILNG G DLTA 20
46.CEILNG L DLTA 91
47.BELW GRD DLTA 21
35.MISC BTU GAIN
13 .EXT WALL LEN : 28 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 46 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 21 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 5632 27390
20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 188 914
21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 11197 75626
22.& BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 212 1429
23.FLOOR SO FT 440 34.BATH(Y*N) N * BASEBRD' : 20 135
-------------------------------------------------------------------------------
ROOM # 11 OF 11 41.WALL G DELTA 20
12.ROOM NAME :BASEMENT 42.WALL L DELTA 91
43.FLOOR G DELTA 0
44.FLOOR L DELTA 91
45.CEILNG G DLTA 0
46.CEILNG L DLTA 0
47.BELW GRD DLTA : 21
35.MISC BTU GAIN :
13 .EXT WALL LEN : 184 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS :
14.EXT WALL HGT : 8 25.HEAT/CL BELOW : SLAB 37.BASEBD BTU/FT : 580
15.WALL R-FCTR 19 26.CEILING R-FCTR: 19 38.PEOPLE BTUS 400
16.WINDOW SQ FT : 12 27.HEAT/CL ABOVE?: Y 39.MOIS TURE 23
17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1
18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE
19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 6532 27390
20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 218 914
21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 30150 75626
22.$ BELOW GRADE: 90 33.KITCHEN(Y/N) N * LOSS CFM: 570 1429
23 .FLOOR SQ FT 1995 34.BATH(Y*N) N * BASEBRD' : 52 135
Load Summary
Manual J8 Load Calculation
Project#:Cerrone
November 14,2016
Project Information
Project#: Cerrone Notes:
Name: Cerrone
Location: Lieberman
Outdoor Conditions Indoor Conditions FloorplaNLevels
Location: Glens Falls AP,New Heating Cooling Ground Floor 1,679 W
York Room Temp: 84'F 68 T
Elevation: 335 ft Design Temp Diff: 88.0'F 17.0'F Total Heated Area: 1,679 ft'
Latitude: 43 Humidity: 35 45 Total Cooled Area: 1,679 ft'
Heating Cooling Moisture Diff(Grains): 46.6
Dry Bulb: 4.0'F 85.0'F Ventilation
Daily Range: Medium Num Occupants: 4
Wet Bulb: 71.0'F
Heating Cooling
Infiltration Type: Outside Air Type: Outside Air
Method: Simple ACH: 0.23 ACH: 0.23
Stories: 1 Outside Air. 65 dm Outside Air. 65 chn
Construction: Average Other Exhaust 65 dm Other Exhaust 65 chn
Exposure Category: Three or Four Exposures
Num Fireplaces: None
Net Air Changes(H/C): 0.42/0.22
Net Flow(H/C): 119 dm/61 arm
Total Heating:75,564 Btulhr Heating Load Breakdown Sensible Load Breakdown
Total Sensible:22,891 Btulhr
Total Latent:4,747 Btulhr
w.r.
Load Breakdown camw
000.
Name Heating Sensible Latent Whn - vns.
Windows' 11,446 8,141 maeuma
Skylights' 0 0
Doors 2,112 672
v aa.sea
Walls 9,756 2,151
Below Grade Wells 0 - y�a.a:in mnm. Vii:.
s.<u.:. :1
Ceilings 5,616 4,595 = van e 3; 31
Floors 0 0
Infiltration I 11,393 1,136 1 1,923 1 Fenestration Load vs Hour of Day -Block Load (Summer)
Internal 2,120 1 800
Other 0 _
Dud Loads 0 0 0 13000
Ventilation 6,188 1,195 2,024
Humidification 0 11000
Piping Load 0 t 9000
_. Legend
Radiant Backloss 29,054 m Load Line
Blower Heat 1,706 7000 Average
AED• 1.175 5000 30 Percent
Total 75,564 22,891 4,747
Total Area 1,679 ft' 1,679 ft' 3000
-Average Load procedure 8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
JSHR:0.83 CFM/SgFt:0.63
MJ8 Tons:2.30 Est. Blower CFM: 1051 Average Load:9,457 Btulhr Peak Load:13,470 Btulhr
SgFt(Ton:729 Excursion Limit:12,295 Btulhr AED Load:1,175 BtWhr
Length=It Area=ft' Temperature='F Flowrete=USGPM Heal Loss=Blu/hr Created Using LoopCAD 2016 Vega Add-On(1 Ill 4/2016)
Ung Heel Lass=Btulhr ft. Rv=hr "
ftF/btu Head Loss=ft water RH=Radiant Floor Heating Version:16.0.0298(TdaO
Be=Baseboard FA=Foroed Air OTH=Other Heating SM=Snawmeft N=Not Heated
See sections at end of report for important Notes,Assumptions and Disclaimers. Page 1 of 2
Project#:Cerrone Load Summary
Name:Cerrone November 14,2016
Warnings
This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in soler load far one or more
rooms.A zoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers).
Disclaimers
With the permission of the Air Conditioning Contractors of America("ACCA"),material is reproduced from Manual J Residential Load Calculation(8th Ed fion)which is copyrighted
by ACCA.The program and data are provided"as is"without warranty of any kind either expressed or Implied.The entire risk as the quality and performance of the program and
data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost profits,lost savings,or other incidental or consequential damages
arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.aoca.urg
ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved.
Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high forthe
momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The
software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so
independently if required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,including Section 1-11 and Section 27.
The calculated values shown in this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results.
You are strongly advised to review all input data carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and
suitability for your application.
IN NO EVENT WILL AVENIR SOFTWARE INC.("AVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL
OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED
TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS
REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE
SOFTWARE LICENSE AGREEMENT.
Length=ft Area=ft' Temperature=-F Flowrate=USGPM Heat Loss=Btuthr Created Using LoopCAD 2016 Mega Add-On(11114/2016)
Unit Heat Loss=Blu/hrft' Rv=hrft''F/btu Head Loss=Itwater RH=Radiant Floor Heating Version:16.0.0298(Trial)
Be=Baseboard FA=Forced Air OTH=Other Heating SM=Brownish N=Not Heated
See sections at end of report for important Notes, Assumptions and Disclaimers. Page 2 of 2
- Load Report
Manual J8 Load Calculation
Project#:Cemone
November 14,2016
Project Information
Project#: Cartons Notes:
Name: Cerrone
Location: Lieberman
Manual J Load Summary
Total Heating: 75,564 Btu/hr Total Sensible: 22,891 Btu/hr Total Latent: 4,747 Btu/hr
Outdoor Conditions Indoor Conditions
Location: Glens Falls AP,New York Heating Cooling
Elevation: 335 ft Room Temp: 84'F 68°F
Latitude: 43 Design Temp Diff: 88.0"F 17.0°F
Heating Cooling Humidity: 35 45
Dry Bulb: 4.0'F 85.0°F Moisture Diff(Grains): 46.6
Daily Range: Medium
Wet Bulb: 71,0^F
Infiltration Ventilation
Method: Simple Num Occupants: 4
Stories: 1 Heating Cooling
Construction: Average Type: Outside Air Type: Outside Air
Exposure Category: Three or Four Exposures ACH: 0.23 ACH: 0.23
Num Fireplaces: None Outside Air: 65 elm Outside Alr: 65 cfm
Net Air Changes(HeattC000: 0.42 10.22 Other Exhaust: 65 cfm Other Exhaust: 65 cfm
Net Flow(Heat/Cool): 119 elm 161 cfm
Floorplan/Levels
Ground Floor 1,679 ft2 Total Heated Area: 1,679 ft'
Total Cooled Area: 1,679 ft-
Length=It
'Length=ft Area=fl' Temperature=°F Flowate=USGPM Heat Loss=Btu/hr Unit Heat Loss=BtuBxrft' Rv=hrft"F/btu Created Using LoopCAD 2016 Viega Add-On(11/14/2016)
Head Loss=ft water RH=Radiant Floor Heating Be=Baseboard FA=Forced Air OTH-Other Heating SM=Snowmelt N=Not Heated Vemion:16.0.0298
(Trial)
See end of report for important Notes and Disclaimers. Page 1 of 7
Name:Cerrone
Load Report
Project k:Cerrone November 14,2016
Constructions
Walls
Code Description I U-Value I Area Heating Cooling
12E-Osw Frame Wall or Partition;Wood Framing;R-19 Insulation in 2 x 6 Stud Cavity; 0.07 1,630 9,7562,151
Stucco or Wood Siding;Plus Interior Finish
Doors
Code IDescription U-Value Area Heating Cooling
11J I Metal Door with Fiberglass Core 0.60 40 2,112 672
Floors
Code Description U-Value Area Heating Cooling
22A-0-r 22A-No Edge Insulation,No insulation Below Floor,any Floor Cover ERRORI 169(P) Hahn o
Ceilings
Code DescriptionU-Value Area Heating Cooling
16A-25ad No radiant barter over ceiling or same type of air space behind an attic knee 0.04 1,679 5,616 4,595
wall;Materials:Asphalt Shingles(a),Metal(m),Wood Shakes(w),Tar/Gravel(x),
Membrane(z),Tile,Slate or Concrete;Colors:Dark(d),Light(1),White(w);
Glazing
Length=it Area=ft- Temperature=•F Floveate=USGPM Heat Loss=Btuthr Unit Heat Loss=Btu/hrft' Rv=hrn"Fnxu Created Using LoopCAD 2016 Viega Add-On(1111412016)
Head Loss=ft water RH=Radiant Floor Heating Be=Baseboard FA=Forced Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial)
See end of report for important Notes and Disclaimers. Page 2 of 7
Name:Cermne
Load Report
Project#:Cartons November 14,2016
Windows
Code Description Wposure U-Value SHGC Area Heating Cooling
108b French Door with Double Pane Clear Glass and Metal NE 0.75 0.47 40 2,640 1,318
with Break Frame,BlindsMedium45(50%),1',V above.
10Bb French Door with Double Pane Clear Glass and Metal SW 0.75 0.47 40 2,640 1,505
with Break Frame,DrapesAverage(50%),1', V above.
1 D-cf Double pane operable window or sliding glass door,with SW 0.49 0.56 45 1,940 1,788
Clear Glass-Insulated Fiberglass Framing,
BlindsMediunA5(50%),1',V above.
1D-cf Double pane operable window or sliding glass door,with SW 0.49 0.56 15 647 596
Clear Glass-Insulated Fiberglass Framing,
BlindsMedium45(50%), 1',V above.
1D-d Double pane operable window or sliding glass door,with NW 0.49 0.56 30 1,294 958
Clear Glass-Insulated Fiberglass Framing,
BlindsMedium45(50%),1',V above.
1 D-cf Double pane operable window or sliding glass door,with NE 0.49 0.56 15 647 479
Clear Glass-Insulated Fiberglass Framing,
BlindsMedium45(50%),1',V above.
1 D-cf Double pane operable window or sliding glass door,with SE 0.49 0.56 6 259 235
Clear Glass-Insulated Fiberglass Framing,
BlindsMedium45(50%),1',V above.
1 D-cf Double pane operable window or sliding glass door,with SE 0.49 0.56 32 1,380 1,263
Clear Glass-Insulated Fiberglass Framing,
BlindsMedium45(50%),1',V above.
Internal Loads Other Loads
Description Sensible Latent Blower Load 1,706 Btu/hr
Default(1,200 Btuh) 1,200 0
4 Occupants: 920 800
Total 2,120 800
Length=n Area=ft- Temperature=-F Flowrate=USGPM Heat Lon=Btu/hr Unit Heat Lon=Btu/hrft, Rv=hrft'-°F/btu Created Using LoopCAD 2016 Viega Add-On(11/1412016)
Head Loss=ft water RH=Radiant Floor Healing Be=Baseboard FA=Forced Air OTH=Other Healing SM=Snowmeft N=Not Heated Vemien:16.0.0298(Trial)
See end of report for important Notes and Disclaimers. Page 3 of 7
Name:Cerrone
Load Report
Project#:Cerrone
November 14,2016
Load Breakdown Heating Load Breakdown
Name Heating Sensible Latent
Windows' 11,446 8,141
Skylights' 0 0
Walls
Doors 2.112 672 Ceilings Doors
Walls 9,756 2,151
Below Grade Walls 0 Windows•
Ceilings 5,616 4,595 Infiltration
Floors 0 0
Infiltration 11,393 1,136 1,923
Internal 2,120 800
Other 0
Ventilation
Duct Loads 0 0 0
ig
Ventilation 6,188 1,195 2,024
Humidification 0Radiant
Piping Load 0
Backless
Radiant Backloss 29,054
Blower Heal 1,706
AED' 1,175 Sensible Load Breakdown
Total 75,564 22,891 4,747
Total Area 1,679 ft' 1 1,679 a'
'Average Load Procedure Windows'
JInfiltra
JSHR:0.83 CFM/Sq Ft:0.63
MJ8 Tons:2.30 Est.Blower CFM: 1051 Walls
SgFt/Ton:729
AED'
Ceilings
Blower Heat
Internal
Ven
Length=It Area=ft' Temperature=T Flowrate=USGPM Heat Loss=Btu/hr Unit Heat Loss=Btu/1r-ft' Rv=hrft''F/btu Created Using LcopCAD 2016 Viega Add-On(11/14/2016)
Head Loss=It water RH=Radiant Floor Heating Be=Baseboard FA=Fomed Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial)
See end of report for important Notes and Disclaimers. Page 4 of 7
Name:Cerrone
Load Report
Project#:Cerrone November 14,2016
AED
Fenestration Load vs Hour of Day -Block Load (Summer)
14000-
13000-
12000-
11000-
10000-
9000-
M
4000130001200011000100009000 m � Load Line
8000-
7000-
6000-
5000-
4000-
3000-
0007000 6000500040003000-
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Average Load: 9,457 Btulhr Peak Load:13,470 Btulhr
Excursion Limit: 12,295 Btulhr AED Load:1,175 Btulhr
Length=8 Area=rt' Temperature=-F Flowrete=USGPM Heat Loss=Btulhr Unit Heat Loss=Btu/hr-ft- Rv=hrW-T/btu Created Using LoopCAD 2016 Viega Add-On(1111412016)
Head Loss=it water RH=Radiant Floor Heeling Be=Baseboard FA=Forced Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial)
See end of report for important Notes and Disclaimers. Page 5 of 7
Name:Cerrone
Load Report
Project#:Carron November 14,2016
Heating Zones
Zone Area Room Temp Total Load
Zone 101 1,679 84 75,564
Heating Rooms
Room Area Room Temp Total Load
Bath 98 84 3,192
BED 2 169 84 9,460
CIGAR 148 84 9,391
Great 406 84 13,480
Kilch 268 84 10,893
Laundry 76 84 3,224
Master Bath 88 84 5,947
Master Bed 300 84 15,359
Mud R 61 84 3,397
Roomm 1 33 84 989
Room 4 33 84 230
Cooling Zones
Zone Area Room Temp AED Sensible Load•
Entire Building 1,679 68 NO 17,869
(Average Load Procedure)
Cooling Rooms
Room Area Room Temp MED Sensible Load'
Bath 98 68 YES 443
BED 2 169 68 NO 2,088
CIGAR 148 68 NO 2,571
Great 406 68 NO 6,070
Kitch 268 68 NO 2,727
Laundry 76 68 YES 397
Master Bath 1 88 68 NO 1,006
Master Bed 300 68 NO 4,193
Mud Rm 61 68 YES 618
Room 1 33 68 YES 143
Room 4 33 1 68 YES 90
(Average Load Procedure)
Length=ft Area=ft' Temperature=T Fluwrate=USGPM Heat Loss=Stulhr Unit Heat Loss=Btwhnft' Rv=hrft"Fibtu Created Using LoopCAD 2016 Viega A4d-On(1111 412 01 6)
Head Loss=R water RH=Radiant Floor Healing Be=Baseboard FA=Forced Air OTH=Other Heating SM=SnowmeH N=Not Heated Vemion:16.0.0298(Trial)
See end of report for important Notes and Disclaimers. Page 6 of 7
Name:Cemone
Load Report
Project#:Cerrone November 14,2016
Warnings
This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or mora rooms.A zoned system may be required or some rooms may
require zone control(provided by individual.motorized,thermostatically controlled dampers).
Disclaimers
With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted by ACCA.The program and data are Provided'as
W without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and data is with you.In no event will ACCA be liable to you for any damages,Including without limitation any
lost profits,lost savings,or other incidental or consequential damages arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.acca.org
ACCA,Manual J and Powered by ACCA Manus]J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved.
Cold weather humidification,or some Iitestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high for the momentary circumstances.Condensation ran occur on
surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The software does not perform calculations for the estimation or detection of possible condensation problems,and it is
the designers(i.e.software users)responsibility to do so independently it required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,including Section 1-11 and Section 27.
The calculated values shown In this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results.You are strongly advised to review all input date
carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application.
IN NO EVENT WILL AVENIR SOFTWARE INC.("AVENIR')OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY
CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS
OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR
ARISING FROM THE USE THIS REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE
AGREEMENT.
Length=ft Area=ft- Temperature='F Flowrate=USGPM Heat Loss=Btuthr Unit Heat Loss=Btu/I Rv=haft'°F/btu Created Using LoopCAO 2016 Vlega Add-On(11/14/2016)
Head Loss=It water RH-Radiant Floor Heating BB=Baseboard FA=Forced Air OTH=Other Heating SM=Snowsnell N=Not Heated Vemion:16.0.029e(Trial)
See end of report for important Notes and Disclaimers. Page 7 of 7
- , Form J 1
Manual J8 Load Calculation
Project#:Cevone
November 14,2016
Project Information
Project#: Cerrone Notes:
Name: Cerrone
Location: Lieberman
Form J1(Summer)
I Hama or R. Cerrone ErMn H.
2 R...m9 Feet W Eaae.ed Wall las
3 CvlliW Height lF4 and Gross Wall Nva lsdFp 10.0 1,893
4 Room Dimvnsioa.IFp and Floor Plan Arta l SRFp 1 a
5 pith;flea•10e,,.1 sold Groff Colli"Ana(SpFlt I 6
H N ebd,
TYq MEryoaurt LonaWeboa Number Panel Faoaa H� Mg NNwLerl9lh ".on S{i8. Ltly
• 108b NE Woo 32.95 0.00 2.040 1,318
e 1090 Sw 00.00 37,63 40.00 2.040 1,505
c tad SW 43.12 3972 a500 1,940 1,T88
3e Windows and 01... a tdd 940 43.12 39.72 15.00 84`7 595
Geon s tDtl NW 43.12 31,92 moo 1.294 908
f 1PC NE 43.12 31.92 1500 00 an
d 113E SE 43.12 39.09 0.00 259 235
n tDG SE 43.12 "as 32.00 1.380 1.203
eb SLTligbb
WoedalMY•blpoorf Ili 5.80 10.80 40.00 2.112 pit
8 Nbove Grant WII•ant 12E4. 598 1.32 1,030 9,735 2.151
P.Mtons
9 9vlow Grade Walls
10 Collings 1pN-25ad 3.34 274 1,1379 5.616 4,595
It Flows a 22.60+ 13345 1891P1 28.0134
Hosting Load I9Wll1 0.425 11.393
12 Imlizadoa Sensible Load 18wh1 EXeC ACH 0.219 Wall 1.0 1,130
oft
hl Load Ihl 1.923
Oecupa fla at 230&M 2H Stub 4 920 800
b Scenario Number Del 1,200
13 Imm,ol Default Adiu•Menlf
d Coa om Applum..
Plain.
0dwr Ilw"611.Wd1h.1 to..
14 satautan sum linea a bvough 13 09.3], 18.814 2.723
15 Duet Load. EHLF d ESGF
ELO
Is Vxrdlaban Loads V.m Chn 55 ECbn 81 0.188 1,193 2,024
17 Wlnivr HunidiRoaben Load GauDaY
Is Pipm,Load
19 a.float 1,70E
20 a r0 so .lon 1.1713
31 1 Total Load sum Imas 13 tlfeogh 19 73.5ea 22.891 4,747
All load values shown in etulhr Created Using LodpCAD 2016 Viega Add-0n(11114/2016)
Vemlw:16.0.0298(Trap
See sections at end of report for important Notes,Assumptions and Disclaimers. Page 1 of 2
Project#:Cerrone Farm J1
Name:Cerrone November 14,2016
Warnings
This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or more
rooms.A zoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers).
Disclaimers
With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted
by ACCA.The program and date are provided"as is"without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and
data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost proms,lost savings,or other incidental or consequential damages
arising out of the use or Inability to use this program or the data.®2015 Air Conditioning Contractors or America.All Rights Reserved.www.acca.org
ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved,
Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high for the
momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The
software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so
independently d required.For guidance and additional cautions refer to ACCA Manuel J 8th Edition,including Section 1-11 and Section 27.
The calculated values shown in this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results.
You are strongly advised to review all Input data carefully,and to have the calculated results reviewed by an experienced healing professional to ensure reasonableness and
suitability for your application.
IN NO EVENT WILL AVENIR SOFTWARE INC.rAVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL
OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED
TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS
REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE
SOFTWARE LICENSE AGREEMENT.
All bad values shown in Btu/hr Created Using LoopCAD 2016 Viega Add-On(1111412016)
Verslon:16.0.0298(Trial)
See sections at end of report for important Notes, Assumptions and Disclaimers. Paget of
- , AED Report
Manual J8 Load Calculation
Project#:Carron
November 14,2016
Project Information
Project#: Carron Notes:
Name: Cerrone
Location: Lieberman
Outdoor Conditions Indoor Conditions Floorplan/Levels
Location: Glens Falls Heating Cooling Ground Floor 1,679 ft'
AP,New York Room Temp: 84°F 68°F
Elevation: 335 ft Design Temp 88.0°F 17.0`F Total Heated Area: 1,679 ft-
Latitude: 43 Diff: Total Cooled Area: 1.679 ft-
Heating Cooling Humidity: 35 45
Dry Bulb: -4.0°F 85.0°F Moisture Diff(Grains): 46.6
Daily Range: Medium
Wet Bulb: 71.0°F
Fenestration Load vs Hour of Day (Summer)
14000-
13000-
12000-
11000-
10000-
9000-
4000130001200011000100009000 Legend
Load Line
ao 8000
Average
7000
— 30 Percent
6000-
5000
4000-
3000-
8
00030008 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Average Load: 9,457 Btu/hr Peak Load:13,470 Btu/hr
Excursion Limit: 12,295 Btulhr AED Load:1,175 Btulhr
All load values shown in Stu/hr Created Using LoopCAD 2016 Vlega Add-0n(11/14/2016)
Version:16.0.0298(Trial)
See sections at end of report for important Notes, Assumptions and Disclaimers. Page 1 of 3
Project#:Cerrone AED Report
Name:Cerrone November 14,2016
Cooling Rooms
Great(Summer) BED 2(Summer)
5000 2000
4000
r 3000
' 0 1000
ce 2000- m
IK:
1000 _ --'
0 0-
8 9 10 11 12 13 14 15 16 17 18 1920 8 9 10111213141516 1718 1920
Hour of Day Hour of Day
Average Load:2,447 Btulhr Peak Load:4,541 Btu/h Average Load:854 Btu/hr Peak Load:1,314 Btu/t
Excursion Limit:3,181 Btu/hr AED Load:1,360 Btu/hl Excursion Limit:1,110 Btu/hr AED Load:204 Btu/hr
Kitch(Summer) Master Bath(Summer)
2000 1000
L �e
Z� 1000-
8
000 8 9 10 11 12 13 14 15 16 17 18 19 20 8 9 10 11 12 13 14'15116 17 18 19 20
Hour of Day Hour of Day
Average Load:1,069 Btu/hr Peak Load:1,655 Btulh Average Load:294 Btulhr Peak Load:563 Btulhr
Excursion Limit:1,390 Btu/hr AED Load:264 Btulhr Excursion Limit:383 Btulhr AED Load:180 Btulhr
Master Bed(Summer) CIGAR(Summer)
5000 3000-
4000-
2000
Z� 3000
m m
2000 1000-
1000 0
8 9 10 11 12 13 14 15 16 17 18 19 20 8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day Hour of Day
Average Load:3,508 Btulhr Peak Load:4,582 Bluth Average Load: 1,284 Btulhr Peak Load:2,292 stuff
Excursion Limit:4,561 Btu/hr AED Load:21 Btulhr Excursion Limit: 1,670 Btu/hr AED Load:622 Btu/hr
All load values shown in Btufnr Created Using LoopCAO 2016 Viega Add-On(11/14)2016)
Version:16.0.0298(Trial)
See sections at end of report for important Notes, Assumptions and Disclaimers. Page 2 of
Project#:Cerrone AED Report
Name:Cerrone November 14,2016
Warnings
This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or more
rooms.Azoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers).
Disclaimers
With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted
by ACCA.The program and data are provided"as is"without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and
data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost profits,lost savings,or other incidental or consequential damages
arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.acca.org
ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of Amenca.All rights reserved.
Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur ifthe absolute humidity of the Indoor air is too high for the
momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The
software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so
independently it required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,Including Sectlon 1-11 and Section 27.
The calculated values shown in this report are based on the data Input by the user of the software.Inaccurate or erroneous data input will resuft in inaccurate or erroneous results.
You are stmngy advised to review all input data carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and
suitability for your application.
IN NO EVENT WILL AVENIR SOFTWARE INC.('AVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL
OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING.BUT NOT LIMITED
TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS
REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE
SOFTWARE LICENSE AGREEMENT.
All bad values shown in Btuhr Created Using LoopCAD 2016 Vega Add-On(11/14/2016)
Verslcn:16.0.0298(Trial)
See sections at end of report for important Notes, Assumptions and Disclaimers. Page 3of 3
LE'GE'ND
SEPTIC PLOT PLAN
I HAVE SEEN OR OBSERVED ALL OBS TS
ETC / � ' �`�(11�(12i1S . ,�d0�d IRF IRON ROD FOUND
SUCH AS HOUSES,WELLS,TREES, FENC �S)r�
1 �`��� IPF IRON PIPE FOUND
SHAWN ON THIS DOCUMENT.I HAVE PERSONALLY IRS IRON ROD SET
� (1SV3VV l�h. � Dd 3�\VH i UTILITY POLE
° fv;E�SURED TH r' CE SET FORTH ON THIS DIAGRAM. _ �o STONE WALL
rl i
W t water x WIRE FENCE
a shut off DATE
O CHAIN LINK FENCE
o — WOOD FENCE
o POINT
F.P. FENCE POST
ohw OVERHEAD WIRES
W catch basin n/f NOW OR FORMERLY
q !� LOT 72 Lands n/f gy 8
in Joseph L. Luzzi, Jr.
& Patricia C. Luzzi `
/V7 .� L. 928 P. 134
4 co if)Z 324 03 W 26.1- �P
292 2S, MA P REFERENCE.
Wwater 97.8 1) "MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC"
N �but off DRIVEWAY DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL U
o, 2S'SID LAND SURVEYORS.CP I W
��� e e\D/Al S " W
R 9A T f�A
)O PROPOSED �� I
\ O �� \ FOUNDATION \ CK 7 1)NOTES:
BASE
E MAP PREPARED FROM A JANUARY 2014 FIELD SURVEY. # a
S2
AREAS= 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1.
\ A �I 0.85l A RES 3) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT C4
2S S\ v I I Lands n OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS 4
w /f OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT
'OF m I 1143.8' William W. Mapes WOULD DISCLOSE.
25 9' D & Loraine Mapes
M L. 1471 P. 2�� 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE
SFT REGARDING DEVELOPMENT OF LAND.
h 3
N o to 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND
`SSts� i7 rn rn SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE
29 �S 3 Im I M �p NEW YORK STATE EDUCATION LAW.
ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE
I� LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.
\I 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM
LOT 10 TAINEDTHERECMAYOIONS BETOTHER UDTILITIESUREMENTS WHICH THEOEXIISTENCEROM OF AREIELD NOTSKNOWN. SIZE,
TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY
n PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR
301 -15- 1 -61- RC 746-2016 TO ANY EXCAVATION.
Foothills Builders Lands n/f
Lot 11, House No. 27 Elk Ridge Drive Alan N. Crisler & �F NEIy PLOT PLAN MADE FOR
Kristen M. Crisler P� �eAMETp }p
SFD w/ garage L. 1467 P. 166 � � � a 9 FOOTS ULLS BUILDERS
LLC�
„�
GRAPHIC SCALE
0 Town of Quee;sbury County of Warren State of New York
50 0 25 50 100 200 _C)
°so540 a RUSSELL E. HOWARD
D sv� LdCEJVSED LAND SURVEYING
342 Main Street, Hudson Falls, New York 12839
( IN FEET ) Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 10/19/16 Sheet 01 of 01
1 inch = 50 ft.
Date Sealed: Scale: 1 inch = 50 feet Revised: Drawing #:13074L11PP
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
R-0 -116• 2z1b
Permit No.rr......................................Cert. O 44898 Cut-in Card No.....................................
Owner.......r ...��......................t3 / .. (iL .......1 11 .L rJ.l .: ......................................... ..v................
Location...r�.7.. "4.1! ....C'`.:L D.�`J. .. .................................................aG. ....,.....................
Installation Consisting of. �.r .4.A.A.. .: ..�.. ".t. �•.•••--•••••••••
/.. "r..l 5.,�.. / A1�.. ...1`7.� f.. ,/Z�tJ.................................................................
....................................................................................................................................................................................
Installed By........t.,.....t1.z1R .......................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making in ctions at any time, and if its
rules are violated,the
``Company shall have the right to rev e s c rt i e.
Date...4., II x...:'1..1..................... INSPECTOR......................:..... ...... ..... .... ' ....... ...
Member N.F.P.A. I.A.E.1.
NACE ENGINEERING, P.C.
169 Haviland Road, Queensbury, NY 12804
Phone-518-745-4400 Fax -518-792-8511
April 17, 2017
Job #46262
Dave Hatin
Town of Queensbury Building Department
Bay Road
Queensbury, NY 12804
RE: Leuci Peggy Ann Road Subdivision- Queensbury(T)
Lot# 11 Septic System
Dear Dave:
This letter is to inform you that we inspected the completed septic system for the house at Lot
#11 in the Leuci Peggy Ann Road Subdivision on December 20, 2016.
The septic system as installed was for a three bedroom house and consisted of a 1,000 gallon
septic tank and 150 lineal feet of absorption trench constructed with stone and perforated pipe.
The system conforms to the requirements of the approved subdivision design drawings.
Please call me if you have any questions or concerns.
Sincerely,
Thomas R. Center Jr., PE
JUL 3 1 2017
SEPTIC SYSTEhig AS BUILT BY NACIE Eli I,I�TIEIERING
4/17/2017 , ���Y�= LEGEND
IRF IRON ROD FOUND
IPF IRON PIPE FOUND
IRS IRON ROD SET
UTILITY POLE
waterer
' "' STONE WALL
t � '�"4 a��-�-„� !��' 0000
a snot off 2.
x WIRE FENCE
_ J8ry '�j�d 0 — CHAIN LINK FENCE
❑ — WOOD FENCE
C POINT
F.P. FENCE POST
ohw- OVERHEAD WIRES '
1
catch basin n/f NOW OR FORMERLY
Q► LOT 12 JosephLandsLuz f Jr.
'0)i a & Patricia C. Luzzi
o to 108.1' N�3�o L. 928 P. 134 w
3h
25.9' MAP REFERENCE.•
;V I sv'ar \ 26.3' 1) MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC"
\ DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL W
c3� LAND SURVEYORS.
0 W
9�yc 2A �jj� 2S\
123.9 �i
' rzl
4a.o' Bcli°iNc F NOTES:ROPOSED �Ac� 1) BASE MAP PREPARED FROM A DECEMBER 2016 FIELD SURVEY. P4
\ DDITION to 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1.j o
j 3 THIS SURVEY WAS PREPARED
j
DISTRIBUTION BOXT ) WITHOUT THE BENEFIT OF AN ABSTRACT �
25.9' jaS �/f OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS w
18.8' C4 OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT 0.
1,000 GAL William W. Mapes WOULD DISCLOSE.
SEPTIC TANK In & Loraine Mapes
26.0' z L. 1471 P. 200 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE
ABSORPTION C REGARDING DEVELOPMENT OF LAND.
HES
3 0 50' EA. I6 N 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND
SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB—DIVISION 2, OF THE
2y6, �SS, s 00 ; NEW YORK STATE EDUCATION LAW.
2 dY F co
0, 6) ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE
LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.
qct 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM
LOT 10 SURFACE LOCATIONS AND MEASUREMENTS OBTAINED FROM A FIELD SURVEY.
THERE MAY BE OTHER UTILITIES WHICH THE EXISTENCE OF ARE NOT KNOWN. SIZE,
TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY
PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR
TO ANY EXCAVATION.
Lands n/f
Alan N. Crisler & MAP OF A SURVEY MADE FOR
Kristen
1467 P. 166eT 1S' (DOWYMM BUILDERS J.fl. _
GRAPHIC SCALE
Town of Queensbury County of Warrel7. State of New York
50 0 25 50 100 200 AM
12M A1MrJ1rjff=
342 Main Street, Hudson Falls, New York 12839
( IN FEET )
1 inch = 50 ft. Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 12/14/16 Sheet 01 of Of
Date Sealed = Scale: 1 mach = 50 feet Revised: Dmwing #:13074L11PPR1