Loading...
RC-000746-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804.5904 (518)761-8201 at Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000746-2016 Date Issued: Friday, April 14, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000746-2016 has been completed. Tax Map Number: 301.15-I-61 Location: 27 ELK RIDGE DR Owner: FOOTHILLS BUILDERS,LLC Applicant: FOOTHILLS BUILDERS,LLC This structure may be occupied as a: Single-Family Dwelling 1,840 sq. ft. and gas stove to be installed in 3-season room By Order of Town Board Garage 506.74 TOWNOF QUEENSSBURAY Issuance of this Certificate of Occupancy DOES NOT relieve the \ /^(((iiivyyllittt"' VVV) - (/ k�— property owner of the responsibility for compliance with Site Plan, ttt�� // Variance,or other issues and conditions as a result of approvals by the Director of Building a@ Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY Qmw 742 Bay Road.Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000746-2016 Tax Map No: 301.15-1-61 Permission is hereby granted to: FOOTHILLS BUILDERS,LLC For property located at: 27 ELK RIDGE DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: FOOTHILLS BUILDERS,LLC Single Family-New $200,000.00 Owner Address: 9 Mountainside DR Total Value $200,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency FOOTHILLS BUILDERS,LLC 9 Mountainside DR Queensbury,NY 12804 Plans&Specifications Single-Family Dwelling 1,840 sq.1t. Garage 506.74 $1,29401 PERMIT FEE PAID-T16S PERMIT EXPIRES: Wednesday,November 15,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before thjexpir i.ondd/ate.) Dated at the Town of eensbu �'(�esd mber 15,2016 SIGNED BY: ,a for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: Permit No. Tax Map ID Permit Fee LC- 2:3 6 2-2 I b Zone Historic? _Yes No Rec Fee °65i — Subdivision Name Lot# Site Plan# Project Location J 4t Z�- Subdivision# 1rtVOtlR� 1205 J TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owners) Address " I�l,U'1 r2lt 1'1 ' C1tt., v�'• 1'1 �t� Phone/Email Applicant Address Phone/Email � t Contractor 1U Utl Address BUILDING 8 COMES Phone/Email Contact Person for Building& Codes Compliance: LCUC i Phone lcl TYPE Or CONSTRUCTION ,/Check all that apply New Addition Alteration 1"floor sf 2"d floor sf Total sf Height Single Family V/ Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Ifo , Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition ....... 2 z s , C\C ,l Source of Heat(circle one) Gas) Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? Site Information: a. Dimensions or acreage of lot b. Is this a comer lot? Yes _No c. Will the grade be changed as a result of construction TYes _No d. Public water or Private well (circle one) Private e. Sewer or Private Septic System (circle one) Sewer Private Value of all work to be performed(labor or materials) $ &6'4 7Zo,o0 DECLARATION.• I. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: M Q.r i L-&_ DATE: 10 Q G - I SIGNATURE: DATE: /0- Q & - 1 to For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: Applicant Name: t�l vs f/o Telephone No.: u Address to be Inspected Z1-6\�-- '\fid -, LQ-r OCT 26 Return Address: S DFQUEENSS ING& CODES Applicant must show exact location and width of driveway(s) to be connected to the tg lacing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale O Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: Tax Map ID TAx MAP 1D: Permit No. P -:, q4(D 20 t to Permit Fee ZONE: APPLICANT ,� 1j� 1��e\,S PHONE/E-MAIL ADDRESS INSTALLER/ PHONE/E-MAIL BUILDER OWNER ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL U, 143 '4 UIR RESIDENCE INFORMATIONVWJN FOUFFNSBURY Year Built #of bedrooms X gallons per bedroom =total Daily flowBUILDING& CODES 1980 or older Garbage grinder installed Yes No 1981.1991 Spa or Hot Tub installed _Yes _jNo 1992-Present PARCEL INFORMATION Topography Flat rolling _Steep slope _%Slope Soil Nature Sand _Loam _Clay _Other Groundwater At what depth: 1},� Bedrock/Impervious material At what depth: N Ft Domestic Water Supply 1' Municipal _Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: I—) per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size IMO gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with 42 stone Total length�_R.;Each Trench a-7) Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: (V( DATE: 10104, i SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 REScheck Software Version 4.6.2 Compliance Certificate Project Lieberman Ranch Energy Code: 2015 IECC Location: Warren County, New York Construction Type: Single-family Project Type: New Construction 301 .15-1 -61 RC 746-2016 Conditioned Floor Area: 1,840 ft2 Foothills Builders Glazing Area 17% Lot 11, House No. 27 Elk Ridge Drive Climate Zone: 6 (8499 HDD) $FD w/ garage Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: FHB Lot 11 VISION Engineering, LLC Queensbury, NY 12804 206 Glen Street Suite 56 Glens Falls, NY 12801 �ompliance: Passes using UA tra'dL-off Compliance: 0.7%Better Than Code Maximum ILA: 275 Your ILA: 273 The%Better or Worse Than Code Index reflects how close to compliance the house is based an code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cant. Assembly or U-Factor ILIA Ceiling 1: Raised or Energy Truss 1,840 38.0 0.0 0.025 46 Wall 1: Wood Frame, 16" o.c. 1,504 21.0 0.0 0.057 70 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 131 0.300 39 Door 1: Solid rEOSBURY N] E - 20 0.250 5 Door 2: Glass `J 53 0.300 16 Door 3: Glassq C 53 0.300 16 Door 4: Solid LO1U20 0.140 3 Wall 2:Wood Frame, 16" o.c N70 21.0 0.0 0.057 3 Door 5: Solid CDES 20 0.200 a Basement Wall 1: Solid Concrete or Masonry 1,390 0.0 15.0 0.046 63 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.340 3 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 17 0.290 5 Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 1 of 10 Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirem is listed in the REScheck Inspection Checklist. r Name-Tifls 151ghsture Dat O w. gy�yp9 fn n s�OA tio. 07906 R�Fc I NP Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance forthe 0 building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1. Construction drawings and ❑Complies 103.2, documentation demonstrate - ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. []Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: :❑Complies 403.7 sized per ACCA Manual S based Btu/hr_ Btu/hr ❑Does Not [PR2]' on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr_ Btu/hr approved by the code official. �❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) RAMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 3 of 10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R-_ R-_ ❑Complies See the Envelope Assemblies [1`04)1 insulation R-value.Where interior R R- ❑Does Not table for values, 4 , insulation is used,verification j❑Not Observable '.,may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall [ Complies [F0511 insulation installed per El Does Not !manufacturer's instructions. ❑Not Observable ❑Not Applicable j 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06)1 .insulation depth of burial or ❑Does Not ;table For values. (distance from top of wall. ;❑Not Observable []Not Applicable sA protective covering is installed ❑Complies 17� to protect exposed exterior ❑Does Not 'I insulation and extends a ❑Not Observable I minimum of 6 in. below grade. ❑Not Applicable j 403.9 Snow-and ice-melting system ❑Complies i [FO12]2 'controls installed. ❑Does Not J ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: ----------- 11 High Impact(Tier 1) Medium Impact(Tier 2) ; Low Impact(Tier 3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 4 of 10 Section Pians Vered Field Vered # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies ;See the Envelope Assemblies 402.3.4 ❑Does Not :table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, .Glazing U-factor(area-weighted : U-_ U-_ ❑Complies See the Envelope assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Nat Observable 402.5 ❑Not Applicable [FR21' 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 1402.4.3 'Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish j❑Does Not and labeled to indicate <_2.0 cfm []Not Observable leakage at 75 Pa. '❑Not Applicable 403.2.1 Supply and return ducts in attics '[]Complies TR1211 insulated >=R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where< 3 inches.Supply and return ducts in other portions of ❑Not Applicable j the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR1513 ducts or plenums. ❑Does Not !+i ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 OF or chilled fluids ❑Does Not below 55 OF are insulated to >_R- ❑Not Observable 3' ❑Not Applicable 403.4.1 Protection of insulation on HVAC '-'❑Complies [FR2411 piping. ❑Does Not ❑Not Observable ; ]Not Applicable j 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 ->R-3. ❑Does Not 01 ❑Not Observable I ❑Not Applicable j 403.6 Automatic or gravity dampers are ❑Complies [FR191= installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Nat Applicable j 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier3) Project Title: Lieberman Ranch Report date: 1026/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 5 of 10 Additional Comments/Assumptions: 1 I High Impact(Tier 1) ',2 1 Medium Impact(Tier 2) %' ;';; Low Impact(Tier 3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 6 of 10 Section Plans Verified Field Verified # insulation Inspection Complies? Comments/Assumptions V& Re IDalue Value 303.1 .All installed insulation is labeled ❑Complies [IN1312 or the installed R-values - -❑Does Not „provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 'wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ;❑Not Applicable j 303.2 ;Wall insulation is installed per ❑Complies [IN411 :manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable j Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 7 of10 Section Plans Verified Field Verified # I Final inspection Provisions Value Value Complies? Comments/Assumptions AReq.ID _ 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, E] Wood ❑ Wood ❑Does Not table for values. 402.2.2• ❑ Steel ❑ Steel 402.2.6 ❑Nat Observable [Fill' ❑Not Applicable 303.1.1.1, :Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 :Blown insulation marked every 300 ft'. ❑Not Observable ❑Not Applicable Vented attics with air permeable ❑Complies insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ...,.;❑Not Applicable r2i24Attic access hatch and door R-_ R-_ ❑Complies insulation aR-value of the ❑Does Not adjacent assembly. j❑Not Observable ❑Not Applicable j 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ I❑Complies [FI17]1 ;ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. j❑Not Observable ❑Not Applicable 403.2.3 :Duct tightness test result of<=4 : cfm/100 cfm/100 ;❑Complies [FI4I1 ;cfm/100 ft2 across the system or ft2 ff ❑Does Not ,<=3 cfm/100 ft2 without air ❑Not Observable :handler @ 25 Pa. For rough-in bests,verification may need to ❑Not Applicable .occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F]2711 :determine air leakage with : ft2 ft2 ❑Does Not ;either: Rough-in test:Total 'leakage measured with a ;❑Not Observable pressure differential of 0.1 inch ❑Nat Applicable ;w.g.across the system including 'the manufacturer's air handler enclosure if installed at time of .test.Postconstruction test:Total :leakage measured with a pressure differential of 0.1 inch w.g.across the entire system ;including the manufacturer's air , :handier enclosure. 403.3.2.1 :Air handler leakage designated ❑Complies [F124]1 .by manufacturer at<=2%of _ ❑Does Not ;design airflow. ❑Not Observable _ ❑Not Applicable j Programmable thermostats `^❑Complies installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ..,I❑No[Applicable Heat pump thermostat installed [ Complies on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable Circulating service hot water ❑Complies systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable - ❑Not Applicable 1 lHigh Impact(Tier 1) 2 Medium Impact (Tier 2) � 3JLow Impact(Tier 3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.10 Value .___—. Value_ x403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable ------ — --------------- 403.2 Hot water boilers supplying heat ❑Complies (F12612 through one-or two-pipe heating El Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]' have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- :❑Not Applicable 'syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F12912 comply with IEEE 515.1 or UL ,❑Does Not 515.Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable j desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. _ 403.5.4 Drain water heat recovery units ❑Complies [F13112 tested in accordance with CSA ❑Does Not B55.1.Potable water-side ❑Not Observable pressure loss of drain water heat recovery units<3 psi for ❑Not Applicable j individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units <2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (F1611 'fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable I Does not apply to low-voltage lighting. EI Applicable j 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not '.., ❑Not Observable ❑Not Applicable j 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 pact(Tier Low Im3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies?. Comments/Assumptions Req.lD_ --_ 401.3 'Compliance certificate posted. ❑Complies [F[7)2 ❑Does Not ❑Not Observable ❑Not Applicable j 303.3 Manufacturer manuals for ❑Complies [1`I18)' mechanical and water heating ❑Does Not j systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) - Medium Impact(Tier 2) 3 1 Low Impact(Tier3) Project Title: Lieberman Ranch Report date: 10/26/16 Data filename: C:\Users\DWR Desktop\Desktop\1197 rescheck.rck Page 10 of10 �( 2015 IECC Energy j Efficiency Certificate Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments Item#:403787 Specification Date: B-06-1 ..', .v.4a ...a L.t SHR 1504 r �; NOV 0 7 2016 SP" vi u5 Heat Recovery Ventilator Product#: 40072 _ ' �c%�E5 -�:,.:_ _ Fans Two(2)factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life o and maintenance-free operation. Heat Recovery Core Aluminum heat recovery core covered by a limited lifetime warranty. Core dimensions are 9"x 9"(229 x 229 mml with a 15"(380 mm)depth.Our heat exchangers are designed and manufactured to withstand extreme temperature variations. Defrost A preset defrost sequence is activated at an outdoor air temperature of 23'F 1-5°C)and lower.During the defrost sequence,the supply blower Fantech's side port connection HRV for budget conscious house projects, shuts down&the exhaust blower switches into high speed to maximize the SHR 1504 unit brings a continuous supply of fresh air into a home the effectiveness of the defrost strategy.The unit then returns to normal while exhausting an equal amount of contaminated air. During winter, operation,and continues cycle. fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs,while during summer,the Serviceability incoming air is pre-cooled if the house is equipped with an air cooling Core,filters,fans and drain pan can be easily accessed through latched system.The SHR 1504 is equipped with automatic defrost mechanisms door.Core conveniently slides out on our new easy glide core guides. 17' so you can use your HRV all year long. (432 mm)of clearance is recommended for removal of core. Features Case • Compact design 24 gauge galvanized steel.Baked powder coated paint. • Fans with backward curved RadiCAL blade Insulation • Electrostatic filters(washable) Cabinet is fully insulated with 1" 125 mm]high density expanded • Aluminum heat recovery core polystyrene. • External screw type dry contacts • Easy Core Guide Channels For Removing Core Filters • Only weighs 45 lbs (20Kg) Two(2)washable electrostatic panel type air filters 8.5"(216mml x 15" (380mm]x 0.125"13mml. Optional Controls • ECO-TouchTM(944929) — Programmable Touch Screen Wall Control Controls • EDF7 (944eea( — Electronic multi-function dehumidistat External three(3)position(Low/Stand By/Medium)rocker switch that will • RTS3 (940376) — 20/40/60 minute over-ride offer continuous ventilation. Fentech offers a variety of external controls. • RTS2 (940164( — 20 minute over-ride [see controls) • MDEH1 (940172) — Oehumidistat Installation Specifications Unit is typically hung by using installation kit supplied with unit.Mounting • Duct size — 6"If 52 mm) bolts provided on top four(4)corners of unit. • Voltage/Phase — 120/1 Warranty • Power rated — 156 W Limited lifetime on aluminum core,7 year on motors,and 5 year on • Amp — 1.3 A parts. • Average airflow — 149 cfm(70 Us) ®0.4'Ps(100Pa1 •��'' fantech •" a systemair company Dimensions&Airflow r fresh air to inside E fresh air from outside stale air ® from inside I0 stale air A�,„4. e c F� o to outside ®®®®®®®®®® 6HR1504 21/4 57 231/2 597 25/8 67 173/8 441 161/8 410 Clearance of 17'1432 mm)in front of the unit Is recommended for removal of core.All units feature three foot plug in power cord with 3-prong plug. Ventilation Performance Airflow((1s1 i 1.2 24 47 71 94300 'dExhaust Net supply airflow 170 1801 149(70) 128 1601 104 1491 77(36) 49(23) 6 1.0 250 E3 Gross supply airsmr 174(B2) 1511711 130(61) 186(50) 79(371 50(24) s 0.6 200 Gross exhaust airflow 1691791 146(6B) 1251591 1001471 751351 46(22 ,', 0.6 150 2 a 0.4 100 9 e 0.2 50 0.0 0 0 50 100 750 200 Airflow fchnl Energy performance 32 0 67 31 72 60 73 -0.11 32 0 109 51 98 59 70 0.00 32 0 161 76 144 55 B3 0.00 -13 -25 a8 32 73 56 77 -0.02 Requirements and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no. 113 Standard applicable to ventilators • Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified Contacts Distributed by: Submitted bv: Date: Quantity: Model: Proiect#: Comments: Location: Architect: Engineer: Contractor: United states 10048 Industrial Blvd.•Lenexa,K3 66215•1.600.747.1762•www.fentech.net Canada 50 KanalAakt Way•Bouctouche,NB E48 3M5•1.800.5653546•www.fantech.net Fantech,reserves the right to modify,at any time and without notice,any or all of its products'features,designs, •••' f a n t e c h components and specifications to maintain their technological leadership position. :��..�1: a systemair company F. W. WEBB COMPANY RESIDENTIAL HEAT LOSS/GAIN CALCULATIONS PREPARED BY SCOTT LANGEWORTHY BR16 PROJECT # : 215118 BY SLL ENTERED 11/04/16 BLDG 1. NAME :CERRONE GAIN BTU: 29390 2. LOCATION :LIEBERMAN GAIN CMF: 981 3. HI DESIGN TMP: 91 8.GRND TEMP 50 LOSS BTU: 75626 4. LO DESIGN TMP: -20 9.COOL AIR TMP: 50 LOSS CFM: 1429 S. ROOM TEMP 71 10.WARM AIR TMP: 120 BASEBRD' : 135 6. LEEWAY 10 TONNAGE 2 .4 7. # OF PEOPLE 5@400 ------------------------------------------------------------------------------- ROOM # 1 OF 11 41.WALL G DELTA 20 12.ROOM NAME :BATH MASTER 42.WALL L DELTA 91 43 .FLOOR G DELTA : 20 44.FLOOR L DELTA : 91 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 91 47.BELW GRD DLTA : 21 35.MISC BTU GAIN : 13.EXT WALL LEN : 17 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS : 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 6 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 956 27390 20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 32 914 21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 2781 75626 22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 53 1429 23 .FLOOR SQ FT 85 34.BATH(Y*N) Y * BASEBRD' : 5 135 ------------------------------------------------------------------------------- ROOM # 2 OF 11 41.WALL G DELTA 20 12.ROOM NAME :LAUNDRY10 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13.EXT WALL LEN : 10 24 .FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 318 27390 20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 11 914 21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 1177 75626 22.W BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 22 1429 23.FLOOR SQ FT 50 34.BATH(Y*N) N * BASEBRD' : 3 135 ------------------------------------------------------------------------------- NAV :s NR, ROOM # 3 OF 11 41.WALL G DELTA 20 12.ROOM NAME :MUD 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13.EXT WALL LEN 5 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 21 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 523 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 17 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 2058 75626 22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 39 1429 23 .FLOOR SQ FT 60 34.BATH(Y*N) N * BASEBRD' : 4 135 ------------------------------------------------------------------------------- ROOM # 4 OF 11 41.WALL G DELTA 20 12.ROOM NAME :WIC 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13.EXT WALL LEN : 0 24 .FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 14 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 158 27390 20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 5 914 21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 529 75626 22.% BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 10 1429 23 .FLOOR SQ FT 35 34.BATH(Y*N) N * BASEBRD' : 1 135 --------------------------------------------------------------' -------- ROOM # 5 OF 11 41.WALL G DELTA 20 12.ROOM NAME :MASTER 42.WALL L DELTA 91 43 .FLOOR G DELTA : 20 44.FLOOR L DELTA : 91 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 91 47.BELW GRD DLTA : 21 35.MISC BTU GAIN : 13.EXT WALL LEN 35 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS : 14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT 0 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 42 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 2061 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 69 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 7798 75626 22.$ BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 147 1429 23.FLOOR SQ FT 294 34.BATH(Y*N) N * BASEBRD' : 14 135 ------------------------------------------------------------------------------- ROOM # 6 OF 11 41.WALL G DELTA 20 12.ROOM NAME :KITCHEN / DINNETT 42.WALL L DELTA 91 43.FLOOR G DELTA : 20 44.FLOOR L DELTA : 91 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 91 47.BELW GRD DLTA : 21 35.MISC BTU GAIN 13 .EXT WALL LEN : 22 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT 9 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 42 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 4079 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 136 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 7272 75626 22.$ BELOW GRADE: 0 33 .KITCHEN(Y/N) Y * LOSS CFM: 137 1429 23.FLOOR SQ FT 264 34.BATH(Y*N) N * BASEBRD' : 13 135 ------------------------------------------------------------------------------ ROOM # 7 OF 11 41.WALL G DELTA 20 12.ROOM NAME :BED 2 42.WALL L DELTA 91 43 .FLOOR G DELTA : 20 44.FLOOR L DELTA : 91 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 91 47.BELW GRD DLTA : 21 35.MISC BTU GAIN : 13.EXT WALL LEN 26 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS : 14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT : 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT 30 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 3052 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 102 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 5142 75626 22.E BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 97 1429 23.FLOOR SQ FT 163 34.BATH(Y*N) N * BASEBRD' : 9 135 ------------------------------------------------------------------------------- ROOM # 6 OF 11 41.WALL G DELTA 20 12.ROOM NAME :BATH 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13.EXT WALL LEN : 8 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 9 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 1130 27390 20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 38 914 21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 2715 75626 22.% BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CEM: 51 1429 23.FLOOR SQ FT 96 34.BATH(Y*N) Y * BASEBRD' : 5 135 ------------------------------------------------------------------------------- ROOM # 9 OF 11 41.WALL G DELTA 20 12.ROOM NAME :CIGAR 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13.EXT WALL LEN 27 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT 30 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 2949 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 98 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 4807 75626 22.4 BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 91 1429 23.FLOOR SQ FT 138 34.BATH(Y*N) N * BASEBRD' : 9 135 ------------------------------------------------------------------------------- ROOM # 10 OF 11 41.WALL G DELTA 20 12.ROOM NAME :GREAT 42.WALL L DELTA 91 43.FLOOR G DELTA 20 44.FLOOR L DELTA 91 45.CEILNG G DLTA 20 46.CEILNG L DLTA 91 47.BELW GRD DLTA 21 35.MISC BTU GAIN 13 .EXT WALL LEN : 28 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : N 37.BASEBD BTU/FT 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 38 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 46 27.HEAT/CL ABOVE?: N 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 21 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 5632 27390 20.N,NE,E,SE. . . S 31.EXTRA PEOPLE * GAIN CFM: 188 914 21.WIN. SHADING N 32.LIGHTS(WATTS) * LOSS BTU: 11197 75626 22.& BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 212 1429 23.FLOOR SO FT 440 34.BATH(Y*N) N * BASEBRD' : 20 135 ------------------------------------------------------------------------------- ROOM # 11 OF 11 41.WALL G DELTA 20 12.ROOM NAME :BASEMENT 42.WALL L DELTA 91 43.FLOOR G DELTA 0 44.FLOOR L DELTA 91 45.CEILNG G DLTA 0 46.CEILNG L DLTA 0 47.BELW GRD DLTA : 21 35.MISC BTU GAIN : 13 .EXT WALL LEN : 184 24.FLOOR R-FACTOR: 19 36.MISC BTU LOSS : 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : SLAB 37.BASEBD BTU/FT : 580 15.WALL R-FCTR 19 26.CEILING R-FCTR: 19 38.PEOPLE BTUS 400 16.WINDOW SQ FT : 12 27.HEAT/CL ABOVE?: Y 39.MOIS TURE 23 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 40.ZONE 1 18.DOOR SQ FT 0 29.SKY LGHT TYPE D ***TOTALS FOR ROOM***ZONE 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR .50 * GAIN BTU: 6532 27390 20.N,NE,E,SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 218 914 21.WIN. SHADING : N 32.LIGHTS(WATTS) * LOSS BTU: 30150 75626 22.$ BELOW GRADE: 90 33.KITCHEN(Y/N) N * LOSS CFM: 570 1429 23 .FLOOR SQ FT 1995 34.BATH(Y*N) N * BASEBRD' : 52 135 Load Summary Manual J8 Load Calculation Project#:Cerrone November 14,2016 Project Information Project#: Cerrone Notes: Name: Cerrone Location: Lieberman Outdoor Conditions Indoor Conditions FloorplaNLevels Location: Glens Falls AP,New Heating Cooling Ground Floor 1,679 W York Room Temp: 84'F 68 T Elevation: 335 ft Design Temp Diff: 88.0'F 17.0'F Total Heated Area: 1,679 ft' Latitude: 43 Humidity: 35 45 Total Cooled Area: 1,679 ft' Heating Cooling Moisture Diff(Grains): 46.6 Dry Bulb: 4.0'F 85.0'F Ventilation Daily Range: Medium Num Occupants: 4 Wet Bulb: 71.0'F Heating Cooling Infiltration Type: Outside Air Type: Outside Air Method: Simple ACH: 0.23 ACH: 0.23 Stories: 1 Outside Air. 65 dm Outside Air. 65 chn Construction: Average Other Exhaust 65 dm Other Exhaust 65 chn Exposure Category: Three or Four Exposures Num Fireplaces: None Net Air Changes(H/C): 0.42/0.22 Net Flow(H/C): 119 dm/61 arm Total Heating:75,564 Btulhr Heating Load Breakdown Sensible Load Breakdown Total Sensible:22,891 Btulhr Total Latent:4,747 Btulhr w.r. Load Breakdown camw 000. Name Heating Sensible Latent Whn - vns. Windows' 11,446 8,141 maeuma Skylights' 0 0 Doors 2,112 672 v aa.sea Walls 9,756 2,151 Below Grade Wells 0 - y�a.a:in mnm. Vii:. s.<u.:. :1 Ceilings 5,616 4,595 = van e 3; 31 Floors 0 0 Infiltration I 11,393 1,136 1 1,923 1 Fenestration Load vs Hour of Day -Block Load (Summer) Internal 2,120 1 800 Other 0 _ Dud Loads 0 0 0 13000 Ventilation 6,188 1,195 2,024 Humidification 0 11000 Piping Load 0 t 9000 _. Legend Radiant Backloss 29,054 m Load Line Blower Heat 1,706 7000 Average AED• 1.175 5000 30 Percent Total 75,564 22,891 4,747 Total Area 1,679 ft' 1,679 ft' 3000 -Average Load procedure 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day JSHR:0.83 CFM/SgFt:0.63 MJ8 Tons:2.30 Est. Blower CFM: 1051 Average Load:9,457 Btulhr Peak Load:13,470 Btulhr SgFt(Ton:729 Excursion Limit:12,295 Btulhr AED Load:1,175 BtWhr Length=It Area=ft' Temperature='F Flowrete=USGPM Heal Loss=Blu/hr Created Using LoopCAD 2016 Vega Add-On(1 Ill 4/2016) Ung Heel Lass=Btulhr ft. Rv=hr " ftF/btu Head Loss=ft water RH=Radiant Floor Heating Version:16.0.0298(TdaO Be=Baseboard FA=Foroed Air OTH=Other Heating SM=Snawmeft N=Not Heated See sections at end of report for important Notes,Assumptions and Disclaimers. Page 1 of 2 Project#:Cerrone Load Summary Name:Cerrone November 14,2016 Warnings This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in soler load far one or more rooms.A zoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers). Disclaimers With the permission of the Air Conditioning Contractors of America("ACCA"),material is reproduced from Manual J Residential Load Calculation(8th Ed fion)which is copyrighted by ACCA.The program and data are provided"as is"without warranty of any kind either expressed or Implied.The entire risk as the quality and performance of the program and data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost profits,lost savings,or other incidental or consequential damages arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.aoca.urg ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved. Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high forthe momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so independently if required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,including Section 1-11 and Section 27. The calculated values shown in this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC.("AVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Length=ft Area=ft' Temperature=-F Flowrate=USGPM Heat Loss=Btuthr Created Using LoopCAD 2016 Mega Add-On(11114/2016) Unit Heat Loss=Blu/hrft' Rv=hrft''F/btu Head Loss=Itwater RH=Radiant Floor Heating Version:16.0.0298(Trial) Be=Baseboard FA=Forced Air OTH=Other Heating SM=Brownish N=Not Heated See sections at end of report for important Notes, Assumptions and Disclaimers. Page 2 of 2 - Load Report Manual J8 Load Calculation Project#:Cemone November 14,2016 Project Information Project#: Cartons Notes: Name: Cerrone Location: Lieberman Manual J Load Summary Total Heating: 75,564 Btu/hr Total Sensible: 22,891 Btu/hr Total Latent: 4,747 Btu/hr Outdoor Conditions Indoor Conditions Location: Glens Falls AP,New York Heating Cooling Elevation: 335 ft Room Temp: 84'F 68°F Latitude: 43 Design Temp Diff: 88.0"F 17.0°F Heating Cooling Humidity: 35 45 Dry Bulb: 4.0'F 85.0°F Moisture Diff(Grains): 46.6 Daily Range: Medium Wet Bulb: 71,0^F Infiltration Ventilation Method: Simple Num Occupants: 4 Stories: 1 Heating Cooling Construction: Average Type: Outside Air Type: Outside Air Exposure Category: Three or Four Exposures ACH: 0.23 ACH: 0.23 Num Fireplaces: None Outside Air: 65 elm Outside Alr: 65 cfm Net Air Changes(HeattC000: 0.42 10.22 Other Exhaust: 65 cfm Other Exhaust: 65 cfm Net Flow(Heat/Cool): 119 elm 161 cfm Floorplan/Levels Ground Floor 1,679 ft2 Total Heated Area: 1,679 ft' Total Cooled Area: 1,679 ft- Length=It 'Length=ft Area=fl' Temperature=°F Flowate=USGPM Heat Loss=Btu/hr Unit Heat Loss=BtuBxrft' Rv=hrft"F/btu Created Using LoopCAD 2016 Viega Add-On(11/14/2016) Head Loss=ft water RH=Radiant Floor Heating Be=Baseboard FA=Forced Air OTH-Other Heating SM=Snowmelt N=Not Heated Vemion:16.0.0298 (Trial) See end of report for important Notes and Disclaimers. Page 1 of 7 Name:Cerrone Load Report Project k:Cerrone November 14,2016 Constructions Walls Code Description I U-Value I Area Heating Cooling 12E-Osw Frame Wall or Partition;Wood Framing;R-19 Insulation in 2 x 6 Stud Cavity; 0.07 1,630 9,7562,151 Stucco or Wood Siding;Plus Interior Finish Doors Code IDescription U-Value Area Heating Cooling 11J I Metal Door with Fiberglass Core 0.60 40 2,112 672 Floors Code Description U-Value Area Heating Cooling 22A-0-r 22A-No Edge Insulation,No insulation Below Floor,any Floor Cover ERRORI 169(P) Hahn o Ceilings Code DescriptionU-Value Area Heating Cooling 16A-25ad No radiant barter over ceiling or same type of air space behind an attic knee 0.04 1,679 5,616 4,595 wall;Materials:Asphalt Shingles(a),Metal(m),Wood Shakes(w),Tar/Gravel(x), Membrane(z),Tile,Slate or Concrete;Colors:Dark(d),Light(1),White(w); Glazing Length=it Area=ft- Temperature=•F Floveate=USGPM Heat Loss=Btuthr Unit Heat Loss=Btu/hrft' Rv=hrn"Fnxu Created Using LoopCAD 2016 Viega Add-On(1111412016) Head Loss=ft water RH=Radiant Floor Heating Be=Baseboard FA=Forced Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial) See end of report for important Notes and Disclaimers. Page 2 of 7 Name:Cermne Load Report Project#:Cartons November 14,2016 Windows Code Description Wposure U-Value SHGC Area Heating Cooling 108b French Door with Double Pane Clear Glass and Metal NE 0.75 0.47 40 2,640 1,318 with Break Frame,BlindsMedium45(50%),1',V above. 10Bb French Door with Double Pane Clear Glass and Metal SW 0.75 0.47 40 2,640 1,505 with Break Frame,DrapesAverage(50%),1', V above. 1 D-cf Double pane operable window or sliding glass door,with SW 0.49 0.56 45 1,940 1,788 Clear Glass-Insulated Fiberglass Framing, BlindsMediunA5(50%),1',V above. 1D-cf Double pane operable window or sliding glass door,with SW 0.49 0.56 15 647 596 Clear Glass-Insulated Fiberglass Framing, BlindsMedium45(50%), 1',V above. 1D-d Double pane operable window or sliding glass door,with NW 0.49 0.56 30 1,294 958 Clear Glass-Insulated Fiberglass Framing, BlindsMedium45(50%),1',V above. 1 D-cf Double pane operable window or sliding glass door,with NE 0.49 0.56 15 647 479 Clear Glass-Insulated Fiberglass Framing, BlindsMedium45(50%),1',V above. 1 D-cf Double pane operable window or sliding glass door,with SE 0.49 0.56 6 259 235 Clear Glass-Insulated Fiberglass Framing, BlindsMedium45(50%),1',V above. 1 D-cf Double pane operable window or sliding glass door,with SE 0.49 0.56 32 1,380 1,263 Clear Glass-Insulated Fiberglass Framing, BlindsMedium45(50%),1',V above. Internal Loads Other Loads Description Sensible Latent Blower Load 1,706 Btu/hr Default(1,200 Btuh) 1,200 0 4 Occupants: 920 800 Total 2,120 800 Length=n Area=ft- Temperature=-F Flowrate=USGPM Heat Lon=Btu/hr Unit Heat Lon=Btu/hrft, Rv=hrft'-°F/btu Created Using LoopCAD 2016 Viega Add-On(11/1412016) Head Loss=ft water RH=Radiant Floor Healing Be=Baseboard FA=Forced Air OTH=Other Healing SM=Snowmeft N=Not Heated Vemien:16.0.0298(Trial) See end of report for important Notes and Disclaimers. Page 3 of 7 Name:Cerrone Load Report Project#:Cerrone November 14,2016 Load Breakdown Heating Load Breakdown Name Heating Sensible Latent Windows' 11,446 8,141 Skylights' 0 0 Walls Doors 2.112 672 Ceilings Doors Walls 9,756 2,151 Below Grade Walls 0 Windows• Ceilings 5,616 4,595 Infiltration Floors 0 0 Infiltration 11,393 1,136 1,923 Internal 2,120 800 Other 0 Ventilation Duct Loads 0 0 0 ig Ventilation 6,188 1,195 2,024 Humidification 0Radiant Piping Load 0 Backless Radiant Backloss 29,054 Blower Heal 1,706 AED' 1,175 Sensible Load Breakdown Total 75,564 22,891 4,747 Total Area 1,679 ft' 1 1,679 a' 'Average Load Procedure Windows' JInfiltra JSHR:0.83 CFM/Sq Ft:0.63 MJ8 Tons:2.30 Est.Blower CFM: 1051 Walls SgFt/Ton:729 AED' Ceilings Blower Heat Internal Ven Length=It Area=ft' Temperature=T Flowrate=USGPM Heat Loss=Btu/hr Unit Heat Loss=Btu/1r-ft' Rv=hrft''F/btu Created Using LcopCAD 2016 Viega Add-On(11/14/2016) Head Loss=It water RH=Radiant Floor Heating Be=Baseboard FA=Fomed Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial) See end of report for important Notes and Disclaimers. Page 4 of 7 Name:Cerrone Load Report Project#:Cerrone November 14,2016 AED Fenestration Load vs Hour of Day -Block Load (Summer) 14000- 13000- 12000- 11000- 10000- 9000- M 4000130001200011000100009000 m � Load Line 8000- 7000- 6000- 5000- 4000- 3000- 0007000 6000500040003000- 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Average Load: 9,457 Btulhr Peak Load:13,470 Btulhr Excursion Limit: 12,295 Btulhr AED Load:1,175 Btulhr Length=8 Area=rt' Temperature=-F Flowrete=USGPM Heat Loss=Btulhr Unit Heat Loss=Btu/hr-ft- Rv=hrW-T/btu Created Using LoopCAD 2016 Viega Add-On(1111412016) Head Loss=it water RH=Radiant Floor Heeling Be=Baseboard FA=Forced Air OTH=Other Heating SM=Snowmeft N=Not Heated Vemion:16.0.0298(Trial) See end of report for important Notes and Disclaimers. Page 5 of 7 Name:Cerrone Load Report Project#:Carron November 14,2016 Heating Zones Zone Area Room Temp Total Load Zone 101 1,679 84 75,564 Heating Rooms Room Area Room Temp Total Load Bath 98 84 3,192 BED 2 169 84 9,460 CIGAR 148 84 9,391 Great 406 84 13,480 Kilch 268 84 10,893 Laundry 76 84 3,224 Master Bath 88 84 5,947 Master Bed 300 84 15,359 Mud R 61 84 3,397 Roomm 1 33 84 989 Room 4 33 84 230 Cooling Zones Zone Area Room Temp AED Sensible Load• Entire Building 1,679 68 NO 17,869 (Average Load Procedure) Cooling Rooms Room Area Room Temp MED Sensible Load' Bath 98 68 YES 443 BED 2 169 68 NO 2,088 CIGAR 148 68 NO 2,571 Great 406 68 NO 6,070 Kitch 268 68 NO 2,727 Laundry 76 68 YES 397 Master Bath 1 88 68 NO 1,006 Master Bed 300 68 NO 4,193 Mud Rm 61 68 YES 618 Room 1 33 68 YES 143 Room 4 33 1 68 YES 90 (Average Load Procedure) Length=ft Area=ft' Temperature=T Fluwrate=USGPM Heat Loss=Stulhr Unit Heat Loss=Btwhnft' Rv=hrft"Fibtu Created Using LoopCAD 2016 Viega A4d-On(1111 412 01 6) Head Loss=R water RH=Radiant Floor Healing Be=Baseboard FA=Forced Air OTH=Other Heating SM=SnowmeH N=Not Heated Vemion:16.0.0298(Trial) See end of report for important Notes and Disclaimers. Page 6 of 7 Name:Cemone Load Report Project#:Cerrone November 14,2016 Warnings This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or mora rooms.A zoned system may be required or some rooms may require zone control(provided by individual.motorized,thermostatically controlled dampers). Disclaimers With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted by ACCA.The program and data are Provided'as W without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and data is with you.In no event will ACCA be liable to you for any damages,Including without limitation any lost profits,lost savings,or other incidental or consequential damages arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.acca.org ACCA,Manual J and Powered by ACCA Manus]J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved. Cold weather humidification,or some Iitestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high for the momentary circumstances.Condensation ran occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so independently it required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,including Section 1-11 and Section 27. The calculated values shown In this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results.You are strongly advised to review all input date carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC.("AVENIR')OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Length=ft Area=ft- Temperature='F Flowrate=USGPM Heat Loss=Btuthr Unit Heat Loss=Btu/I Rv=haft'°F/btu Created Using LoopCAO 2016 Vlega Add-On(11/14/2016) Head Loss=It water RH-Radiant Floor Heating BB=Baseboard FA=Forced Air OTH=Other Heating SM=Snowsnell N=Not Heated Vemion:16.0.029e(Trial) See end of report for important Notes and Disclaimers. Page 7 of 7 - , Form J 1 Manual J8 Load Calculation Project#:Cevone November 14,2016 Project Information Project#: Cerrone Notes: Name: Cerrone Location: Lieberman Form J1(Summer) I Hama or R. Cerrone ErMn H. 2 R...m9 Feet W Eaae.ed Wall las 3 CvlliW Height lF4 and Gross Wall Nva lsdFp 10.0 1,893 4 Room Dimvnsioa.IFp and Floor Plan Arta l SRFp 1 a 5 pith;flea•10e,,.1 sold Groff Colli"Ana(SpFlt I 6 H N ebd, TYq MEryoaurt LonaWeboa Number Panel Faoaa H� Mg NNwLerl9lh ".on S{i8. Ltly • 108b NE Woo 32.95 0.00 2.040 1,318 e 1090 Sw 00.00 37,63 40.00 2.040 1,505 c tad SW 43.12 3972 a500 1,940 1,T88 3e Windows and 01... a tdd 940 43.12 39.72 15.00 84`7 595 Geon s tDtl NW 43.12 31,92 moo 1.294 908 f 1PC NE 43.12 31.92 1500 00 an d 113E SE 43.12 39.09 0.00 259 235 n tDG SE 43.12 "as 32.00 1.380 1.203 eb SLTligbb WoedalMY•blpoorf Ili 5.80 10.80 40.00 2.112 pit 8 Nbove Grant WII•ant 12E4. 598 1.32 1,030 9,735 2.151 P.Mtons 9 9vlow Grade Walls 10 Collings 1pN-25ad 3.34 274 1,1379 5.616 4,595 It Flows a 22.60+ 13345 1891P1 28.0134 Hosting Load I9Wll1 0.425 11.393 12 Imlizadoa Sensible Load 18wh1 EXeC ACH 0.219 Wall 1.0 1,130 oft hl Load Ihl 1.923 Oecupa fla at 230&M 2H Stub 4 920 800 b Scenario Number Del 1,200 13 Imm,ol Default Adiu•Menlf d Coa om Applum.. Plain. 0dwr Ilw"611.Wd1h.1 to.. 14 satautan sum linea a bvough 13 09.3], 18.814 2.723 15 Duet Load. EHLF d ESGF ELO Is Vxrdlaban Loads V.m Chn 55 ECbn 81 0.188 1,193 2,024 17 Wlnivr HunidiRoaben Load GauDaY Is Pipm,Load 19 a.float 1,70E 20 a r0 so .lon 1.1713 31 1 Total Load sum Imas 13 tlfeogh 19 73.5ea 22.891 4,747 All load values shown in etulhr Created Using LodpCAD 2016 Viega Add-0n(11114/2016) Vemlw:16.0.0298(Trap See sections at end of report for important Notes,Assumptions and Disclaimers. Page 1 of 2 Project#:Cerrone Farm J1 Name:Cerrone November 14,2016 Warnings This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or more rooms.A zoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers). Disclaimers With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted by ACCA.The program and date are provided"as is"without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost proms,lost savings,or other incidental or consequential damages arising out of the use or Inability to use this program or the data.®2015 Air Conditioning Contractors or America.All Rights Reserved.www.acca.org ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America.All rights reserved, Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur if the absolute humidity of the indoor air is too high for the momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so independently d required.For guidance and additional cautions refer to ACCA Manuel J 8th Edition,including Section 1-11 and Section 27. The calculated values shown in this report are based on the data input by the user of the software.Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all Input data carefully,and to have the calculated results reviewed by an experienced healing professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC.rAVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. All bad values shown in Btu/hr Created Using LoopCAD 2016 Viega Add-On(1111412016) Verslon:16.0.0298(Trial) See sections at end of report for important Notes, Assumptions and Disclaimers. Paget of - , AED Report Manual J8 Load Calculation Project#:Carron November 14,2016 Project Information Project#: Carron Notes: Name: Cerrone Location: Lieberman Outdoor Conditions Indoor Conditions Floorplan/Levels Location: Glens Falls Heating Cooling Ground Floor 1,679 ft' AP,New York Room Temp: 84°F 68°F Elevation: 335 ft Design Temp 88.0°F 17.0`F Total Heated Area: 1,679 ft- Latitude: 43 Diff: Total Cooled Area: 1.679 ft- Heating Cooling Humidity: 35 45 Dry Bulb: -4.0°F 85.0°F Moisture Diff(Grains): 46.6 Daily Range: Medium Wet Bulb: 71.0°F Fenestration Load vs Hour of Day (Summer) 14000- 13000- 12000- 11000- 10000- 9000- 4000130001200011000100009000 Legend Load Line ao 8000 Average 7000 — 30 Percent 6000- 5000 4000- 3000- 8 00030008 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Average Load: 9,457 Btu/hr Peak Load:13,470 Btu/hr Excursion Limit: 12,295 Btulhr AED Load:1,175 Btulhr All load values shown in Stu/hr Created Using LoopCAD 2016 Vlega Add-0n(11/14/2016) Version:16.0.0298(Trial) See sections at end of report for important Notes, Assumptions and Disclaimers. Page 1 of 3 Project#:Cerrone AED Report Name:Cerrone November 14,2016 Cooling Rooms Great(Summer) BED 2(Summer) 5000 2000 4000 r 3000 ' 0 1000 ce 2000- m IK: 1000 _ --' 0 0- 8 9 10 11 12 13 14 15 16 17 18 1920 8 9 10111213141516 1718 1920 Hour of Day Hour of Day Average Load:2,447 Btulhr Peak Load:4,541 Btu/h Average Load:854 Btu/hr Peak Load:1,314 Btu/t Excursion Limit:3,181 Btu/hr AED Load:1,360 Btu/hl Excursion Limit:1,110 Btu/hr AED Load:204 Btu/hr Kitch(Summer) Master Bath(Summer) 2000 1000 L �e Z� 1000- 8 000 8 9 10 11 12 13 14 15 16 17 18 19 20 8 9 10 11 12 13 14'15116 17 18 19 20 Hour of Day Hour of Day Average Load:1,069 Btu/hr Peak Load:1,655 Btulh Average Load:294 Btulhr Peak Load:563 Btulhr Excursion Limit:1,390 Btu/hr AED Load:264 Btulhr Excursion Limit:383 Btulhr AED Load:180 Btulhr Master Bed(Summer) CIGAR(Summer) 5000 3000- 4000- 2000 Z� 3000 m m 2000 1000- 1000 0 8 9 10 11 12 13 14 15 16 17 18 19 20 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hour of Day Average Load:3,508 Btulhr Peak Load:4,582 Bluth Average Load: 1,284 Btulhr Peak Load:2,292 stuff Excursion Limit:4,561 Btu/hr AED Load:21 Btulhr Excursion Limit: 1,670 Btu/hr AED Load:622 Btu/hr All load values shown in Btufnr Created Using LoopCAO 2016 Viega Add-On(11/14)2016) Version:16.0.0298(Trial) See sections at end of report for important Notes, Assumptions and Disclaimers. Page 2 of Project#:Cerrone AED Report Name:Cerrone November 14,2016 Warnings This application has glass areas that produced relatively large cooling loads for part of the day.Zoning may be required to overcome spikes in solar load for one or more rooms.Azoned system may be required or some rooms may require zone control(provided by individual,motorized,thermostatically controlled dampers). Disclaimers With the permission of the Air Conditioning Contractors of America('ACCA'),material is reproduced from Manual J Residential Load Calculation(8th Edition)which is copyrighted by ACCA.The program and data are provided"as is"without warranty of any kind either expressed or implied.The entire risk as the quality and performance of the program and data is with you.In no event will ACCA be liable to you for any damages,including without limitation any lost profits,lost savings,or other incidental or consequential damages arising out of the use or inability to use this program or the data.®2015 Air Conditioning Contractors of America.All Rights Reserved.www.acca.org ACCA,Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of Amenca.All rights reserved. Cold weather humidification,or some lifestyles that produce excessive moisture,may cause condensation to occur ifthe absolute humidity of the Indoor air is too high for the momentary circumstances.Condensation can occur on surfaces or concealed within the structure,and can lead to mold,mildew,frost damage,and moisture damage.The software does not perform calculations for the estimation or detection of possible condensation problems,and it is the designers(i.e.software users)responsibility to do so independently it required.For guidance and additional cautions refer to ACCA Manual J 8th Edition,Including Sectlon 1-11 and Section 27. The calculated values shown in this report are based on the data Input by the user of the software.Inaccurate or erroneous data input will resuft in inaccurate or erroneous results. You are stmngy advised to review all input data carefully,and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC.('AVENIR-)OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT,NEGLIGENCE,STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL,INCIDENTAL,INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER(INCLUDING.BUT NOT LIMITED TO,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE),EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT,AND REGARDLESS OF THE FORM OF THE ACTION,SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. All bad values shown in Btuhr Created Using LoopCAD 2016 Vega Add-On(11/14/2016) Verslcn:16.0.0298(Trial) See sections at end of report for important Notes, Assumptions and Disclaimers. Page 3of 3 LE'GE'ND SEPTIC PLOT PLAN I HAVE SEEN OR OBSERVED ALL OBS TS ETC / � ' �`�(11�(12i1S . ,�d0�d IRF IRON ROD FOUND SUCH AS HOUSES,WELLS,TREES, FENC �S)r� 1 �`��� IPF IRON PIPE FOUND SHAWN ON THIS DOCUMENT.I HAVE PERSONALLY IRS IRON ROD SET � (1SV3VV l�h. � Dd 3�\VH i UTILITY POLE ° fv;E�SURED TH r' CE SET FORTH ON THIS DIAGRAM. _ �o STONE WALL rl i W t water x WIRE FENCE a shut off DATE O CHAIN LINK FENCE o — WOOD FENCE o POINT F.P. FENCE POST ohw OVERHEAD WIRES W catch basin n/f NOW OR FORMERLY q !� LOT 72 Lands n/f gy 8 in Joseph L. Luzzi, Jr. & Patricia C. Luzzi ` /V7 .� L. 928 P. 134 4 co if)Z 324 03 W 26.1- �P 292 2S, MA P REFERENCE. Wwater 97.8 1) "MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC" N �but off DRIVEWAY DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL U o, 2S'SID LAND SURVEYORS.CP I W ��� e e\D/Al S " W R 9A T f�A )O PROPOSED �� I \ O �� \ FOUNDATION \ CK 7 1)NOTES: BASE E MAP PREPARED FROM A JANUARY 2014 FIELD SURVEY. # a S2 AREAS= 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1. \ A �I 0.85l A RES 3) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT C4 2S S\ v I I Lands n OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS 4 w /f OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT 'OF m I 1143.8' William W. Mapes WOULD DISCLOSE. 25 9' D & Loraine Mapes M L. 1471 P. 2�� 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE SFT REGARDING DEVELOPMENT OF LAND. h 3 N o to 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND `SSts� i7 rn rn SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE 29 �S 3 Im I M �p NEW YORK STATE EDUCATION LAW. ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE I� LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES. \I 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM LOT 10 TAINEDTHERECMAYOIONS BETOTHER UDTILITIESUREMENTS WHICH THEOEXIISTENCEROM OF AREIELD NOTSKNOWN. SIZE, TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY n PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR 301 -15- 1 -61- RC 746-2016 TO ANY EXCAVATION. Foothills Builders Lands n/f Lot 11, House No. 27 Elk Ridge Drive Alan N. Crisler & �F NEIy PLOT PLAN MADE FOR Kristen M. Crisler P� �eAMETp }p SFD w/ garage L. 1467 P. 166 � � � a 9 FOOTS ULLS BUILDERS LLC� „� GRAPHIC SCALE 0 Town of Quee;sbury County of Warren State of New York 50 0 25 50 100 200 _C) °so540 a RUSSELL E. HOWARD D sv� LdCEJVSED LAND SURVEYING 342 Main Street, Hudson Falls, New York 12839 ( IN FEET ) Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 10/19/16 Sheet 01 of 01 1 inch = 50 ft. Date Sealed: Scale: 1 inch = 50 feet Revised: Drawing #:13074L11PP COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL R-0 -116• 2z1b Permit No.rr......................................Cert. O 44898 Cut-in Card No..................................... Owner.......r ...��......................t3 / .. (iL .......1 11 .L rJ.l .: ......................................... ..v................ Location...r�.7.. "4.1! ....C'`.:L D.�`J. .. .................................................aG. ....,..................... Installation Consisting of. �.r .4.A.A.. .: ..�.. ".t. �•.•••--••••••••• /.. "r..l 5.,�.. / A1�.. ...1`7.� f.. ,/Z�tJ................................................................. .................................................................................................................................................................................... Installed By........t.,.....t1.z1R .......................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making in ctions at any time, and if its rules are violated,the ``Company shall have the right to rev e s c rt i e. Date...4., II x...:'1..1..................... INSPECTOR......................:..... ...... ..... .... ' ....... ... Member N.F.P.A. I.A.E.1. NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-8511 April 17, 2017 Job #46262 Dave Hatin Town of Queensbury Building Department Bay Road Queensbury, NY 12804 RE: Leuci Peggy Ann Road Subdivision- Queensbury(T) Lot# 11 Septic System Dear Dave: This letter is to inform you that we inspected the completed septic system for the house at Lot #11 in the Leuci Peggy Ann Road Subdivision on December 20, 2016. The septic system as installed was for a three bedroom house and consisted of a 1,000 gallon septic tank and 150 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr., PE JUL 3 1 2017 SEPTIC SYSTEhig AS BUILT BY NACIE Eli I,I�TIEIERING 4/17/2017 , ���Y�= LEGEND IRF IRON ROD FOUND IPF IRON PIPE FOUND IRS IRON ROD SET UTILITY POLE waterer ' "' STONE WALL t � '�"4 a��-�-„� !��' 0000 a snot off 2. x WIRE FENCE _ J8ry '�j�d 0 — CHAIN LINK FENCE ❑ — WOOD FENCE C POINT F.P. FENCE POST ohw- OVERHEAD WIRES ' 1 catch basin n/f NOW OR FORMERLY Q► LOT 12 JosephLandsLuz f Jr. '0)i a & Patricia C. Luzzi o to 108.1' N�3�o L. 928 P. 134 w 3h 25.9' MAP REFERENCE.• ;V I sv'ar \ 26.3' 1) MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC" \ DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL W c3� LAND SURVEYORS. 0 W 9�yc 2A �jj� 2S\ 123.9 �i ' rzl 4a.o' Bcli°iNc F NOTES:ROPOSED �Ac� 1) BASE MAP PREPARED FROM A DECEMBER 2016 FIELD SURVEY. P4 \ DDITION to 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1.j o j 3 THIS SURVEY WAS PREPARED j DISTRIBUTION BOXT ) WITHOUT THE BENEFIT OF AN ABSTRACT � 25.9' jaS �/f OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS w 18.8' C4 OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT 0. 1,000 GAL William W. Mapes WOULD DISCLOSE. SEPTIC TANK In & Loraine Mapes 26.0' z L. 1471 P. 200 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE ABSORPTION C REGARDING DEVELOPMENT OF LAND. HES 3 0 50' EA. I6 N 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB—DIVISION 2, OF THE 2y6, �SS, s 00 ; NEW YORK STATE EDUCATION LAW. 2 dY F co 0, 6) ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES. qct 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM LOT 10 SURFACE LOCATIONS AND MEASUREMENTS OBTAINED FROM A FIELD SURVEY. THERE MAY BE OTHER UTILITIES WHICH THE EXISTENCE OF ARE NOT KNOWN. SIZE, TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR TO ANY EXCAVATION. Lands n/f Alan N. Crisler & MAP OF A SURVEY MADE FOR Kristen 1467 P. 166eT 1S' (DOWYMM BUILDERS J.fl. _ GRAPHIC SCALE Town of Queensbury County of Warrel7. State of New York 50 0 25 50 100 200 AM 12M A1MrJ1rjff= 342 Main Street, Hudson Falls, New York 12839 ( IN FEET ) 1 inch = 50 ft. Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 12/14/16 Sheet 01 of Of Date Sealed = Scale: 1 mach = 50 feet Revised: Dmwing #:13074L11PPR1