Loading...
CC-000712-2016 l TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 -- Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000712-2016 Date Issued: Tuesday, December 12, 2017 This is to certify that work requested to be done as shown by Permit Number CC-000712-2016 has been completed. Tax Map Number: 302.6-1-58.1 Location: 704 GLEN ST Owner: LANDCRAFTER,LLC Applicant: Buy Low Flooring This structure may be occupied as a:Commercial Interior Alterations 2070 s.f. Buy Low Carpet,Suite#1 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, 44t Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. - TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000712-2016 Tax Map No: 302.6-1-58.1 Permission is hereby granted to: John Cart For property located at: 704 GLEN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: LANDCRAFTER,LLC BusinessOffice-Alteration $50,000.00 Owner Address: 9 Halada DR Total Value $50,000.00 Lake George,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency Butch Barrett 204 Burquist RD Ft.Ann,NY 12827 Plans&Specifications Commercial Interior Alterations 2070 s.f. Buy Low Carpet,Suite 91 $414.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,November 18,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the axpi.ration date.) Dated at the Town<Queens {/ /J Fri y mber 18,2016 SIGNED BY: /a for the Town of Queensbury. Director of Building&Code Enforcement rkCUNl JLrAL 6'1'KUUTUKL AYYLIUN111UP1N Office Use Only Date: I-D/I 2j/ (� Permit No. CC., Tax Map ID ��2 •(0 - �, 1 Permit Fee *?t Zone Historic? _Yes V No R@&We r1vo Cum I l Fj'4 Subdivision Name Lot# Site Plan# Subdivision# Project Location �1 U�° I,OW S i -A TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owner(s) Address . Phone/Email -Dtq(o Applicant CLV Address ���� 1�) S5 Phone/EmailTJ 6 ^ 13 Contractor Address T:)VTG1A Phone/Email S i ib _22-72-- S S<b Contact Person for Building&Codes Compliance: �Gi� /G7 b nN Phone VL s�550 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 21 floor sf Total sf Height Single Family Two-Family Multi-Family (#of units Townhouse Business Office X L S Retail-Mercantile Factory-Industrial d Attached Garage (1. 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition L.6v 6PT-m- -' Source of Heat(circle one) lag) Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances&Chimneys Are there structures not shown on plot plan? c, Are there easements on the property? y Site Information: a. Dimensions or acreage of lot b. Is this a comer lot? Yes _No c. Will the grade be changed as a result of construction Yes __Id_No d. Public water or Private well (circle one) ublic Private e. Sewer or Private Septic System(circle one) Oewe Private Value of all work to be performed (labor or materials) $ - DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. 1 also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINTNAME: — DATE: ( � I SIGNATURE: DATE: L b For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.(2;i�.- y.' Cert. N2 4 0 6 3 4 Cut-in Card No..................................... .... ...�4ACE �.1.���/�.�../r.'. ............................. y �,/J..r Location.4 � .`?!............� �-:.t ..... ....... :1...' r �. ............. .C..�f..0.. .... / 9 Installation Consisting of.l...L,/.�.....s�9lif. .r'U y1�,.s,�.� � � ...T.IV.14 ...C.-e— .................................................. .................................................................................................................................................................................... Installed By............v.. h. Y.C....................................................Lic.No. .................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making ' ections at any time, and if its rules are violated,the Company shall have the right to r e this c ificate. Date./Z.-I.15-.114. 7 ..... .... .. `••� ................ INSPECTOR...... ..........: �... .... �':..::.......................... Member N.F.P.A.,I.A.E.I. CLFIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Buy Low Law Office 704 Upper Glen CO-000712 -2016 FELE COPY Plan review based on submittals: • Provide layout of exit/ emergency lighting, including exterior • Verify FE location and inspection • Verify aisles / Storage requirements • Carbon monoxide detection required • Verify compliant locks / latches — • Knox Box required on exterior • An NFPA compliant sprinkler system is required. A layout and hydraulic calculations to be submitted prior to installation. NFA 13 compliance report required at completion Ar�,4 --- :L Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal's Office • Phone: 518-761-8206 - Fax: 518-745-4437 firemarslwl fteensbury.net • www.qyeensbuM.net COMcheck Software Version 4.0.5.1 Interior Lighting Compliance Certificate Project Information CF�k LC CQ_`Y I, Energy Code: 2015 IECC G Project Title: buy low rental Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 704 Glen street john Can shale miller SUITE 1 landcrafter Ilc miller designs queensbury, NY 12804 704 glen street 19 prospect street queensbury, NY 12804 warrensburg, NY 12885 518-623-3084 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts 1191:2 (B X C) 1-FIRST FLOOR(Common Space Types:Office-Enclosed) 1044 1.11 1159 2-SECOND FLOOR(Common Space Types:Office-Enclosed) 1111 1.11 1233 Total Allowed Watts= 2392 Proposed Interior Lighting Power A B C D E Fixture ID : Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. FIRST FLOOR(Common Space Types:Office-Enclosed 1044 sa.ft.l LED 1:LED MR 10W: 1 26 10 260 SECOND FLOOR(Common Space Types-Office-Enclosed 1111 sa ft) LED 2:LED MR 10W: 1 14 10 140 Total Proposed Watts= 400 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date b� Project Title: buy low rental Report date: 11/14/16 Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 1 of 5 bl.cck COMcheck Software Version 4.0.5.1 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan ReviewComplies? Comments/Assumptions & Reg. D C103,2 Plans,specifications,and/or ❑Complies [PR41' calculations provide all Information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 I High Impact(Tier 1) ;Y-, Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: buy low rental Report date: 11/14/16 Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 2 of 5 bl.cck Section # Rough-in Electrical Inspection Complies? Comments/Assumptions & Reg. D C405.2.1 lighting controls installed to uniformly ❑Complies [EL1511 'reduce the lighting load by at least ❑Does Not 50%. ❑Not Observable ❑Not Applicable C405.2.1 .Occupancy sensors installed in ❑Complies (EL18]1 required spaces. ❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies C405.2.2. per approved lighting plans and all ❑Does Not 3manual controls readily accessible and ❑Not Observable [EI-2312 visible to occupants. ❑Not Applicable C405.2.2. Automatic controls to shut off all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ❑Not Observable El Not Applicable C405.2.3 Daylight zones provided with ❑Complies [EL1612 individual controls that control the ❑Does Not lights independent of general area ❑ lighting. Not Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies 0405.23, equipped with required lighting ❑Does Not 1, controls. 2405.2.3. ❑Not Observable 2 ❑Not Applicable [EL2011 C405.23, Enclosed spaces with daylight area ❑Complies C405.2.3. under skylights and rooftop monitors !❑Does Not 11 are equipped with required lighting C405.2.3. controls. ❑Not Observable 3 ❑Not Applicable [EL2111 C405.2.4 Separate lighting control devices for ❑Complies [EL411 'specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable 0405.2.4 Additional interior lighting power ❑Complies [EI-811 allowed for special functions per the ❑Does Not approved lighting plans and is Not Observable automatically controlled and separated from general lighting. ❑Not Applicable 0405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6)1 'face. ❑Does Not [-]Not Observable []Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) i ,,: Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: buy low rental Report date: 11/14/16 Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 3 of 5 bI.cck Section # Final InspectionComplies? Comments/Assumptions & Reg. D C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the []Does Not 2 building owner or designated ]F117]3 representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. IFI1811 lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Not Observable plans,demonstrating proposed watts are less than or equal to allowed ❑Not Applicable watts. 0408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ❑Does Not [F[16]3 of system acceptance. ❑Not Observable'. ❑Not Applicable C4083 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration,adjustment, []Does Not programming,and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: buy low rental Report date: 11/14/16 Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 4 of 5 bl.cck r Project Title: buy low rental Report date: 11/14/16 Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 5 of 5 bl.cck SprinlIder Head Schedule W o HYDRAULIC NOTES: Symbol Count Thread K—Facto, Description Note w O 12 1/2" 1 5.6 V2TG8 1,/2 CIR 155 C PDR on Drop 3/8'CONCRETE ANCHOR DESIGN AREA 3: 12 = Total Number of Heads This Floor a 3/8'ALL THREAD ROD ®_ADJUSTABLE RING HANGER - 1ST FLOOR CLASSIFIED AS A LIGHT SYMBOL/LINE LEGEND o w PREVIOUSLY INSTALLED NEW SPRINKLER PIPING 0 HAZARD OCCUPANCY, .10 GPM/SF OVER DRY PENDENT SPRINKLER =gpm@ - LH a o 1034 ._ — — — EXISTING SYSTEM PIPING CONCRETE ANCHOR,ROD AND RING THE ENTIRE 1ST FLOOR WITH AND OUTSIDE @ 70 psi z Z NOT TO S_KEHOSE ALLOWANCE OF 100 GPM, ANDA m Hose alawance ® 1" RISER TO 2ND FLOOR Hzw F MAXIMUM SPRINKLER SPACING OF 225MAIN RISER a. = Area 3 - 1034 Ft' m 6 w SQ/FT. No V5453 9 40 i i 34 33 m - _ _ 1 � �1 NOTES F° � 4111 C 1_0 "2_4 5 42 3 C •,-0 y 41 35 _ 1. THE DRY TYPE SPRINKLER SYSTEM FOR _ TOP BEAM CLAMP FOR THE LAW OFFICE AT BUY LOW CARPET TO FOR FLANGED W-BEAMS x o BE DESIGNED IN ACCORDANCE WITH NFPA 3/8'ALL THREAD ROD u 59 58 46 47 / , 39 37 13, ALL STATE AND LOCAL BUILDING c H o' NNT ION., CADMIUM OR ZINC x 56 2-3 1 - - 6 , , CODES, AND THE OWNERS SPECIFICATIONS. _ RIC J EN ADJUSTABLE RING 2 -1, 0 1-0 ®HANGER PREVIOUSLY INSTALLED----_,, - JL43' 38 w N II A DRY PENDENT SPRINKLER. — y CERTIFIED TOP BEAM CLAMP,ROD,AND RING — — TIE INTO NEW 2" MAIN r— x� 2. ALL DRY SYSTEM PIPING TO NOT TOS E i I n°' �' n TYPE E, GRADE A, BLACK SCHEDULE 40. z; WITH 2"X1" MECH. TEE / DO oo8_8o, 3. ALL THREADED FITTINGS TO BE CAST IRON 48 49 44Zp 1CLASS 125. E cfl1- K 1-07- 3-11rcc 0 4-60 5, r, '�'3 . 28 4. ALL GROOVED FITTINGS TO BE DUCTILE N 5 6 a N o 2" RISER ;. � _ e ;23 -_C6 32 -o IRON CONFORMING TO ASTM A-536. _ ` s N o ! �' TO 2ND v, f U -='2 z 31 y a _ N FLOOR °-s = _ o m & ATTIC $ FS O oar / ] 52 4 5. ALL SPRINKLER PIPING TO BE HUNG PER 2, 2B 25 NEPA 13 USING ONE OF THE HANGER DETAILS SHOWN ON THIS DRAWING. N w W U 4 U o 5 ST FLOOR 6. ALL PENETRATIONS THROUGH SMOKE u Q 2" RISER FROM BARRIERS OR FIRE RATED WALLS TO BE ° r. Q BASEMENT TO IST FLOOR , PACKED AND SEALED TO MEET THE 0 0o U cn C: 5" VIKING DRY VALVE i�-°- INTEGRITY OF THE WALL OR BARRIER. `� C x o r p wiz a � —j � E [-s-o] 7. ALL MATERIAL AND EQUIPMENT USED TO F ni >d E BE U.L. LISTED AND APPROVED FOR FIRE s M Co F- U S 34 ---------------------------- g-4rr- ------------------------ - PROTECTION. '' c 0s m N OR 1 2 o p a 2-°[ 6-_0 ] 8. SLOPE DRY SYSTEM PIPING BACK TO pi t- `r o ¢ °' WATER SUPPLY: oe ,5 — o-IIn —~� VALVE AS FOLLOWS: U STATIC PRESSURE 91 PSI Tav oa CUT IN 5" x MECH. TEE —MAINS: 1/4" EVERY 10 Lo M 0 RESIDUAL PRESSURE 90 PSIs FLOW 716 GPM 8OV INTO EXISTING 5" MAIN. -BRANCH LINES: 1/2" EVERY 10' M BASEMENT-VALVE ROOM '' 2E c 00 SCALE:i!4-=r-o- CID — J Z M N O 0 I {{ {{ a 0 t",3 i L'�:+� 111 d w C rIx IL g C4co 4! :'- KEY PLAN W i FIRE PROTECTION PLAN-1ST FLOOR&BASEMENT NOT TO SCALE - N SCAT: If--VSHEET 1 OF 2 Sprinkler Head Schedule U o Symbol Count Thread K—Factor Description Note F 0 4 1/2" 5.6 V2704 1/2 OR 155 B UP an Sprig —3/8•SIDE SAMMY ® 1 1" 5.6 4 V3606 T,/2 0-12.00 155 WH PDR C4 3/8'ALL THREAD ROD 4 5 1/2" 5.6 V2710 1/2 QR 155 WH HSWR o 0 ° 5 8.0 V3416 17 32 QR 155 C HSWR ADJUSTABLE RING HANGER ;� � 3/4" / 15 = Total Number of Heads This Floor z c z o SIDE SAMMY,ROD AND RING 1 ���µ�n� ;f z o HOT TOSGIE Jz 12 11 10 5-,.. liVE LEGEND 0 E \ o s 4 3 - oR 1x 1x 1x w 1x tx �°-6 - 2-4 10-0 10-0 10-0 MAIN RISER m [ 2-9 ] '" HYDRAULIC NOTES: _ Area 1 - 490 F1' � iDesign Area No. 1 — OHI DESIGN AREA 1: 9 Density 0.15 Area 490 I r — j Includes 9Pgpm H se allowance --- ATTIC - ATTIC SPACE CLASSIFIED AS AN ORDINARY psi NPTIONgT i 3/8'SIDE SAMW SCALE:I =1'-0 C 8 �o ADJUSTABLE RING HANGER 3/8"ALL THREAD ROD HAZARD GROUP 1 OCCUPANCY DUE TO o r RIC J EN a cJ MECHANICAL EQUIPMENT. 5 N 11 y CERTIFIED SAMMY WOOD SCREW,ROD AND RING '7 r,or TO—E RISER FROM ST FLOOR - HYDRAULICALLY DESIGNED FOR .15 Z V N N' TO ATTIC SPRINKLERS GPM/SF OVER THE ENTIRE ATTIC WITH AN OWNER TO PROVIDE 8"X8" SOFFIT OUTSIDE HOSE ALLOWANCE OF 250 GPM, AND A MAXIMUM SPRINKLER SPACING OF 130 SO/FT PER SPRINKLER HEAD. DESIGN AREA 2 - - s € O , C F C 9 1 ' I ' CEILING - THE ROOM DESIGN METHOD WAS UTILIZED N T G OFFICE 2 FOR THE 2ND FLOOR HYDRAULIC OFFICE 1 CALCULATION PER NFPA 13 CHAPTER 11 C 9-7 , 'a�X;,9 _xSECTION 11.2.3.3 O u ,s ,a hoe 18 OR J3 - 2ND FLOOR IS CLASSIFIED AS A LIGHT -xo HAZARD OCCUPANCY, .10 GPM/SF OVER OPEN SPACE THE HYDRAULICALLY MOST DEMANDING � o m DN EXISTING CEILIN 10' CEILING ROOM PLUS 2 SPRINKLERS. WITH AN w 2 7- OUTSIDE OUTSIDE HOSE ALLOWANCE OF 100 GPM. a z BA CQ MAXIMUM SPRINKLER SPACING OF r; � N Area 2 - 679 Ft' EXTENDED COVERAGE HORIZONTAL d Design Area No. 2 — LH SIDEWALL NOT TO EXCEED 16 X16 PER Density 0.10 Area 679 THE MANUFACTURERS CUT SHEET. co N =j Flow 211 gpm @ 62 psi N M Ln Includes 100 gom Hose allowance M c 2ND FLOOR ! M SCALE:1/4-=1•-0' C C m 100 coCDdl_c ,°z - IL EIrCq SI KEY PLAN W FIRE PROTECTION PLAN 2ND FLOOR&AMC NOT TO SCALE N SCALE 1„=I— SHEET 2 OF 2 Current Estimated Estimated Max. \lax. Parking Lot Required - & Area Per Use Employees Seating Capacity Parking Potential Uses (sq.R.) Per Use Capacity Per Use Per Use Existing Carpet Warehouse 5,925.60 1 employees 0 48 2 Total _ (Req.Code=1 per employee+1 company vehicle) I company vehicle I Existing Carpet Retail Space 1,512.82 n/a 0 48 10 Total - - (Req.Code=5 per 1,000 sq ft of GLFA) Flex Space/Food Service Establishment 1,427.92 4 60 48 15(guest) (Req.Code=15 sq.R.per seat) 839.21(Dining) 2(employee) (Req.Code=1 per every 4 seats+ 583.71(Kitchen) - - I per every 2 employees) 17Total _ 1 Flex Space/Personal Service 1,378.04 n/a 0 48 5 Total W (Req.Code=I per 300 sq R of GLFA) •. Flex Space/Rear Office 730.24 n/a 0 48 2 Total � (Req.Code=I per 300 sq ft of GLFA) c' - in � Flex Space/2nd Floor Office 3.534.SS n!a 0 48 12 Total (Req.Code=I per 300 sq R of GLFA) INDICATES NEW CONSTRUCTION OR RENOVATION DESIGNCRITERIA: O WEATHERING SEVEREZONEIS TERMITES SLIGHT 00 DECAY "Imm SLIGHT � DESIGN TEMP. ]6080EGREE GAYS Lands N/F of Upper SEISMIC SEISMIC 02 Glen Realty inc. �i';( AIR FREEZE INDEX 666 767/215FROST LINE • t ICE 6 WATER UNDERLAYMENT 2P MIN. _ ROOD HAZARD—TO BE DET.BY TOWN ZONING DEPT. 65 �y SITE ELEVATION ABOVE SEA LEVEL —FT 2 FIRST FLOOR LIVE LOAD 40 PSF _ ;y FIRST nc RDEADLOAD 10PBF '.1 ` SECOND FLOOR INE LOAD 40 PSF - - "� SECOND FLOOR DEAD LOAD IOPSF " W ROOF DEAD LOAD I P6F a2.�IZ• 'la :F'� GROUND SHOW LOAD 60 PSF .. ISM' J W a N ��y', VAND LOAD SO MPH,]SEC.GUST o%N d Sheet Index I.� tPID Name A-01 MAIN LEVEL t� j i u s ti ah A-02 MAIN LEVEL SOUTH 39 A-03 MAIN LEVEL(MIDDLE) I - A-04 MAIN LEVEL NORTH LL° u°Oi N A-05 2nd 8 3rd FLOOR PLANS J A-06 ELEVATION VIEWS A-07 ELEVATIONS - �^ A-08 FOUNDATIONS i3iip j1 Si (y t(( A-09 FOUNDATIONS - t,2;.i°• Orta; I y A-10 FRAMING 1 anu"` s a t • -•,r^"'v A-71 FRAMING 00 a 1 1 1 : ;t zf`i L - \/ A-12 SECTIONS in 8 as i ��; - - �/ A-13 SECTIONS r- 3 I �a MD 1 s MILLER DESIGNS ! — {•tit a ` L ti ,,ttom�` l 2�•.5 3t 2 L9 PLANS STATUS: a�s.. � - '� lPrefrrimryl CPrd6..q2 W DRAWN BY: SHALE MILLER ZIs� /L� P—ECTwra LLI � lF/ Buy Low Warehouse LOT LAYOUT IS SCHEMATIC ONLY, REFER Glen Steet/Lafayette St. Queensbury NY TO ENVIRONMENTAL DESIGN Warren County NY PARTNERSHIP LLC (PAGE 1) FOR ACTUAL MAIN LEVEL oQ N LOT AREAS, PARKING, CURB CUTS...) A-01 ENTRANCE t / SIGN ' t X AIN R .. i. .E. . - FASIInc .. rur _ 12860FXT A-O6 18 's ISTIN6 LIGHT POLE s zs LVL (3)2X E1 3 PLY 13/i"X14"LVL 1 HEADER (3)2X6 SNOS EACH END W/ONE KING SND F F - - 8 UP 3 PLY 13/4"X14"LVL • voce PD HEADER A 20 MIN X6 STUDS EACH END W/ONE KIN ` \Y- p00R KING SND STAIR 7 6X6 N2 YPPT ST .T. SPACE .. IN EBSQ66•SD52-WE PO_STS.TO CIA IN MATERIAL TO FOOD SERVICE • MIN.8"To MAX F COLUMN _1 TRA 4CE lI a 3-2X12 42 SPF HEADERS ENT CE 588.71 sq STOR. t. B<TH�vr R 6X6 P.T.POSTS SET IN CBSQ66-SD52 POST -- . BASE SET IN ZSE PAD - - S I+ � -1 -13 COMMON 2 'R i.11-L BATH HALL P ` __ 3 ' 1 ' � - - •�' '-..., .p,e Q 3-PLY 1 3/4"XI - �- •� 125"DROPPED LVL CARRY - INDIGATE 5 SET CARRY BEAM AND POSTS M RENOVATI AND NEW CONSTRUCTION OR PSL POST SET REMOVE EXISTING]01575AT STAIR RENOVATION - IN EXISTING WALL _ TO SUPPORT ROOF TRIMMER(2X12)REMOVE,RELOCAT, A U '"'cET Nvuem • _ - _ - - / CARRY BEAM 2X6 RANKERS EACH SIDE SECTION I.IARKER INDICATES PAGE WHERE SECTION CAN BE FOUND - OF POST -. q (2)PLY 1.7.'X 11.25' _ MD HEADER W EACH END ONE KING MILLER DESIGNS SND ENTRANCE i.A1, NOTE: ENTIRE BUILDING IS PROTECTED BY AN 6X6# POST SET IN CBSQ66-SD POST AUTOMATIC SPRINKLER BASE POSTS BE CLAD EXISTING PILASTE IN MATERIAL TO TE SYSTEM. DESIGNED BY MIN.8"TO MAY 2" MANUFACTURER COLUMN PLANS STATUS: GLASS ENTRANCE DOORS / `P,``m­l - iPnGrtvnary2 TO BE TEMPERED G X S TEMPERED O DRAWN BY: SHALE MILLER FIXED GLASS aaaEcr wFo AKLh—F&INTERIOR WALL FRAMING: Buy Low Warehouse �cb 2X4,2X6 STPs~.7�`;@ 36"D.C.,DBL TO -FLEX S PACE - Glen Steet/Lafayette St. PLATE SINGLE BASE'±:ATE(P.T.IF IN Queensbury NY DOOR:T.B.D.BASED ON CONTACT WITH CONCRETE).SOLID Warren County NY OCCUPANCY OF SPACE BLOCKING AT W ABOVE BASE PLATE, RETAIL _ AT TIME OF RENTAL AND WO.0 ABOVE THAT IF sNEEr mLe TING LIGHT APPLICABLE.1/2"DRYWALL SHEATHING EACH SIDE. MAIN LEVEL SOUTH 3_2.5 POST 1 ,512 . 82 sa ft 6'X 5 TEMPERED v— A_02