CC-000712-2016 l
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
-- Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: CC-000712-2016 Date Issued: Tuesday, December 12, 2017
This is to certify that work requested to be done as shown by Permit Number CC-000712-2016
has been completed.
Tax Map Number: 302.6-1-58.1
Location: 704 GLEN ST
Owner: LANDCRAFTER,LLC
Applicant: Buy Low Flooring
This structure may be occupied as a:Commercial Interior Alterations 2070 s.f.
Buy Low Carpet,Suite#1 By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, 44t
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
- TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: CC-000712-2016
Tax Map No: 302.6-1-58.1
Permission is hereby granted to: John Cart
For property located at: 704 GLEN ST
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: LANDCRAFTER,LLC BusinessOffice-Alteration $50,000.00
Owner Address: 9 Halada DR Total Value $50,000.00
Lake George,NY 12845
Contractor or Builder's Name/Address Electrical Inspection Agency
Butch Barrett
204 Burquist RD
Ft.Ann,NY 12827
Plans&Specifications
Commercial Interior Alterations 2070 s.f.
Buy Low Carpet,Suite 91
$414.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,November 18,2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the axpi.ration date.)
Dated at the Town<Queens {/ /J Fri y mber 18,2016
SIGNED BY: /a for the Town of Queensbury.
Director of Building&Code Enforcement
rkCUNl JLrAL 6'1'KUUTUKL AYYLIUN111UP1N Office Use Only
Date: I-D/I 2j/ (� Permit No. CC.,
Tax Map ID ��2 •(0 - �, 1 Permit Fee *?t
Zone Historic? _Yes V No R@&We r1vo Cum I l Fj'4
Subdivision Name Lot# Site Plan#
Subdivision#
Project Location �1 U�° I,OW S i -A
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit feels).
Primary Owner(s)
Address .
Phone/Email -Dtq(o
Applicant CLV
Address ���� 1�) S5
Phone/EmailTJ 6 ^ 13
Contractor
Address T:)VTG1A
Phone/Email S i ib _22-72-- S S<b
Contact Person for Building&Codes Compliance: �Gi� /G7 b nN Phone VL s�550
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration I"floor sf 21 floor sf Total sf Height
Single Family
Two-Family
Multi-Family
(#of units
Townhouse
Business Office X L S
Retail-Mercantile
Factory-Industrial d
Attached Garage
(1. 2, 3, 4+)
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business
Proposed use of building or addition L.6v 6PT-m- -'
Source of Heat(circle one) lag) Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances&Chimneys
Are there structures not shown on plot plan? c,
Are there easements on the property? y
Site Information:
a. Dimensions or acreage of lot
b. Is this a comer lot? Yes _No
c. Will the grade be changed as a result of construction Yes __Id_No
d. Public water or Private well (circle one) ublic Private
e. Sewer or Private Septic System(circle one) Oewe Private
Value of all work to be performed (labor or materials) $ -
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes,local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. 1 also understand that I /we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINTNAME: — DATE: ( � I
SIGNATURE: DATE: L b
For office use only
Operating Permit Issued: _Yes —No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No.(2;i�.- y.' Cert. N2 4 0 6 3 4 Cut-in Card No.....................................
.... ...�4ACE �.1.���/�.�../r.'. ............................. y �,/J..r
Location.4 � .`?!............� �-:.t ..... ....... :1...' r �. ............. .C..�f..0.. ....
/ 9
Installation Consisting of.l...L,/.�.....s�9lif. .r'U y1�,.s,�.� � � ...T.IV.14
...C.-e— ..................................................
....................................................................................................................................................................................
Installed By............v.. h. Y.C....................................................Lic.No.
..................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making ' ections at any time, and if its
rules are violated,the Company shall have the right to r e this c ificate.
Date./Z.-I.15-.114. 7 ..... .... .. `••�
................ INSPECTOR...... ..........: �... .... �':..::..........................
Member N.F.P.A.,I.A.E.I.
CLFIRE MARSHAL'S OFFICE
Town of Queensbury
742 Bay Road, Queensbury, NY 12804
" Home of Natural Beauty ... A Good Place to Live "
PLAN REVIEW
Buy Low Law Office
704 Upper Glen
CO-000712 -2016 FELE COPY
Plan review based on submittals:
• Provide layout of exit/ emergency lighting, including exterior
• Verify FE location and inspection
• Verify aisles / Storage requirements
• Carbon monoxide detection required
• Verify compliant locks / latches —
• Knox Box required on exterior
• An NFPA compliant sprinkler system is required. A layout and
hydraulic calculations to be submitted prior to installation. NFA 13
compliance report required at completion
Ar�,4 --- :L
Michael J Palmer
Fire Marshal
742 Bay Road
Queensbury NY 12804
firemarshal@queensbury.net
Fire Marshal's Office • Phone: 518-761-8206 - Fax: 518-745-4437
firemarslwl fteensbury.net • www.qyeensbuM.net
COMcheck Software Version 4.0.5.1
Interior Lighting Compliance Certificate
Project Information CF�k
LC CQ_`Y I,
Energy Code: 2015 IECC G
Project Title: buy low rental
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
704 Glen street john Can shale miller
SUITE 1 landcrafter Ilc miller designs
queensbury, NY 12804 704 glen street 19 prospect street
queensbury, NY 12804 warrensburg, NY 12885
518-623-3084
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts 1191:2 (B X C)
1-FIRST FLOOR(Common Space Types:Office-Enclosed) 1044 1.11 1159
2-SECOND FLOOR(Common Space Types:Office-Enclosed) 1111 1.11 1233
Total Allowed Watts= 2392
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
FIRST FLOOR(Common Space Types:Office-Enclosed 1044 sa.ft.l
LED 1:LED MR 10W: 1 26 10 260
SECOND FLOOR(Common Space Types-Office-Enclosed 1111 sa ft)
LED 2:LED MR 10W: 1 14 10 140
Total Proposed Watts= 400
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name-Title Signature Date
b�
Project Title: buy low rental Report date: 11/14/16
Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 1 of 5
bl.cck
COMcheck Software Version 4.0.5.1
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan ReviewComplies? Comments/Assumptions
& Reg. D
C103,2 Plans,specifications,and/or ❑Complies
[PR41' calculations provide all Information ❑Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 I High Impact(Tier 1) ;Y-, Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: buy low rental Report date: 11/14/16
Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 2 of 5
bl.cck
Section
# Rough-in Electrical Inspection Complies? Comments/Assumptions
& Reg. D
C405.2.1 lighting controls installed to uniformly ❑Complies
[EL1511 'reduce the lighting load by at least ❑Does Not
50%. ❑Not Observable
❑Not Applicable
C405.2.1 .Occupancy sensors installed in ❑Complies
(EL18]1 required spaces. ❑Does Not
❑Not Observable
❑Not Applicable
C405.2.1, Independent lighting controls installed ❑Complies
C405.2.2. per approved lighting plans and all ❑Does Not
3manual controls readily accessible and ❑Not Observable
[EI-2312
visible to occupants.
❑Not Applicable
C405.2.2. Automatic controls to shut off all ❑Complies
1 building lighting installed in all ❑Does Not
[EL22]2 buildings. ❑Not Observable
El Not Applicable
C405.2.3 Daylight zones provided with ❑Complies
[EL1612 individual controls that control the ❑Does Not
lights independent of general area
❑
lighting. Not Observable
❑Not Applicable
C405.2.3, Primary sidelighted areas are ❑Complies
0405.23, equipped with required lighting ❑Does Not
1, controls.
2405.2.3. ❑Not Observable
2 ❑Not Applicable
[EL2011
C405.23, Enclosed spaces with daylight area ❑Complies
C405.2.3. under skylights and rooftop monitors !❑Does Not
11 are equipped with required lighting
C405.2.3. controls. ❑Not Observable
3 ❑Not Applicable
[EL2111
C405.2.4 Separate lighting control devices for ❑Complies
[EL411 'specific uses installed per approved ❑Does Not
lighting plans. ❑Not Observable
❑Not Applicable
0405.2.4 Additional interior lighting power ❑Complies
[EI-811 allowed for special functions per the ❑Does Not
approved lighting plans and is Not Observable
automatically controlled and
separated from general lighting. ❑Not Applicable
0405.3 Exit signs do not exceed 5 watts per ❑Complies
[EL6)1 'face. ❑Does Not
[-]Not Observable
[]Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) i ,,: Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: buy low rental Report date: 11/14/16
Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 3 of 5
bI.cck
Section
# Final InspectionComplies? Comments/Assumptions
&
Reg. D
C303.3, Furnished O&M instructions for ❑Complies
C408.2.5. systems and equipment to the []Does Not
2 building owner or designated
]F117]3 representative. ❑Not Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
IFI1811 lighting power is consistent with what ❑Does Not
is shown on the approved lighting ❑Not Observable
plans,demonstrating proposed watts
are less than or equal to allowed ❑Not Applicable
watts.
0408.2.5. Furnished as-built drawings for ❑Complies
1 electric power systems within 90 days ❑Does Not
[F[16]3 of system acceptance.
❑Not Observable'.
❑Not Applicable
C4083 Lighting systems have been tested to ❑Complies
[F133]1 ensure proper calibration,adjustment, []Does Not
programming,and operation. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: buy low rental Report date: 11/14/16
Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 4 of 5
bl.cck
r
Project Title: buy low rental Report date: 11/14/16
Data filename: C:\Users\shale\Documents\2016 Miller Designs\john carr\BUY LOW LAWYER\COMCHECK 12015 Page 5 of 5
bl.cck
SprinlIder Head Schedule W o
HYDRAULIC NOTES: Symbol Count Thread K—Facto, Description Note w
O 12 1/2" 1 5.6 V2TG8 1,/2 CIR 155 C PDR on Drop
3/8'CONCRETE ANCHOR DESIGN AREA 3: 12 = Total Number of Heads This Floor
a
3/8'ALL THREAD ROD
®_ADJUSTABLE RING HANGER - 1ST FLOOR CLASSIFIED AS A LIGHT SYMBOL/LINE LEGEND o w
PREVIOUSLY INSTALLED NEW SPRINKLER PIPING 0
HAZARD OCCUPANCY, .10 GPM/SF OVER DRY PENDENT SPRINKLER =gpm@
- LH a o
1034 ._ — — — EXISTING SYSTEM PIPING
CONCRETE ANCHOR,ROD AND RING THE ENTIRE 1ST FLOOR WITH AND OUTSIDE @ 70 psi z Z
NOT TO S_KEHOSE ALLOWANCE OF 100 GPM, ANDA m Hose alawance ® 1" RISER TO 2ND FLOOR Hzw F
MAXIMUM SPRINKLER SPACING OF 225MAIN RISER a. =
Area 3 - 1034 Ft' m 6
w
SQ/FT. No V5453 9 40 i i 34 33 m -
_ _ 1 � �1 NOTES F° �
4111 C 1_0 "2_4 5 42 3 C •,-0 y
41 35 _
1. THE DRY TYPE SPRINKLER SYSTEM FOR _
TOP BEAM CLAMP FOR THE LAW OFFICE AT BUY LOW CARPET TO
FOR FLANGED W-BEAMS x
o
BE DESIGNED IN ACCORDANCE WITH NFPA
3/8'ALL THREAD ROD u 59 58 46 47 / , 39 37 13, ALL STATE AND LOCAL BUILDING c H o' NNT ION.,
CADMIUM OR ZINC x 56 2-3 1 - -
6 , , CODES, AND THE OWNERS SPECIFICATIONS. _ RIC J EN
ADJUSTABLE RING 2 -1, 0 1-0
®HANGER PREVIOUSLY INSTALLED----_,, - JL43' 38 w N II A
DRY PENDENT SPRINKLER. — y CERTIFIED
TOP BEAM CLAMP,ROD,AND RING — — TIE INTO NEW 2" MAIN r— x� 2. ALL DRY SYSTEM PIPING TO
NOT TOS E i I n°' �' n TYPE E, GRADE A, BLACK SCHEDULE 40. z;
WITH 2"X1" MECH. TEE / DO oo8_8o, 3. ALL THREADED FITTINGS TO BE CAST IRON
48 49 44Zp 1CLASS 125. E cfl1- K
1-07- 3-11rcc
0 4-60 5, r, '�'3 . 28 4. ALL GROOVED FITTINGS TO BE DUCTILE N 5 6 a N o
2" RISER ;. � _ e ;23 -_C6 32 -o IRON CONFORMING TO ASTM A-536. _ ` s N o
! �' TO 2ND v, f U -='2 z 31 y a _ N
FLOOR °-s = _ o m
& ATTIC $ FS O
oar
/ ] 52 4 5. ALL SPRINKLER PIPING TO BE HUNG PER
2, 2B 25 NEPA 13 USING ONE OF THE HANGER
DETAILS SHOWN ON THIS DRAWING. N w W U 4 U o
5 ST FLOOR
6. ALL PENETRATIONS THROUGH SMOKE u Q
2" RISER FROM BARRIERS OR FIRE RATED WALLS TO BE ° r. Q
BASEMENT TO IST FLOOR , PACKED AND SEALED TO MEET THE 0 0o U cn C:
5" VIKING DRY VALVE i�-°- INTEGRITY OF THE WALL OR BARRIER. `� C
x o r p
wiz a � —j � E
[-s-o] 7. ALL MATERIAL AND EQUIPMENT USED TO F ni >d E
BE U.L. LISTED AND APPROVED FOR FIRE
s M Co F- U
S 34
---------------------------- g-4rr-
------------------------ - PROTECTION. '' c
0s m N
OR 1 2 o p a
2-°[ 6-_0 ] 8. SLOPE DRY SYSTEM PIPING BACK TO pi t- `r o ¢ °'
WATER SUPPLY: oe ,5 — o-IIn —~� VALVE AS FOLLOWS: U
STATIC PRESSURE 91 PSI Tav oa
CUT IN 5" x MECH. TEE —MAINS: 1/4" EVERY 10 Lo M
0
RESIDUAL PRESSURE 90 PSIs
FLOW 716 GPM 8OV INTO EXISTING 5" MAIN.
-BRANCH LINES: 1/2" EVERY 10' M
BASEMENT-VALVE ROOM '' 2E c 00
SCALE:i!4-=r-o- CID
— J Z M N
O
0
I {{ {{ a
0
t",3 i L'�:+� 111 d w C rIx IL
g
C4co
4!
:'- KEY PLAN W i
FIRE PROTECTION PLAN-1ST FLOOR&BASEMENT NOT TO SCALE -
N SCAT: If--VSHEET 1 OF 2
Sprinkler Head Schedule
U o
Symbol Count Thread K—Factor Description Note F
0 4 1/2" 5.6 V2704 1/2 OR 155 B UP an Sprig
—3/8•SIDE SAMMY ® 1 1" 5.6 4 V3606 T,/2 0-12.00 155 WH PDR C4
3/8'ALL THREAD ROD 4 5 1/2" 5.6 V2710 1/2 QR 155 WH HSWR o 0
° 5 8.0 V3416 17 32 QR 155 C HSWR
ADJUSTABLE RING HANGER ;� � 3/4" /
15 = Total Number of Heads This Floor z c
z o
SIDE SAMMY,ROD AND RING 1 ���µ�n� ;f z o
HOT TOSGIE Jz 12 11 10 5-,.. liVE LEGEND 0 E \ o
s
4 3 -
oR 1x 1x 1x w
1x tx �°-6
- 2-4 10-0 10-0 10-0 MAIN RISER m
[ 2-9 ] '"
HYDRAULIC NOTES: _
Area 1 - 490 F1'
� iDesign Area No. 1 — OHI DESIGN AREA 1:
9 Density 0.15 Area 490
I r — j
Includes 9Pgpm H se allowance
--- ATTIC - ATTIC SPACE CLASSIFIED AS AN ORDINARY psi
NPTIONgT
i 3/8'SIDE SAMW SCALE:I =1'-0 C 8 �o
ADJUSTABLE RING HANGER 3/8"ALL THREAD ROD HAZARD GROUP 1 OCCUPANCY DUE TO
o r RIC J EN a
cJ MECHANICAL EQUIPMENT. 5 N 11
y CERTIFIED
SAMMY WOOD SCREW,ROD AND RING '7
r,or TO—E
RISER FROM ST FLOOR - HYDRAULICALLY DESIGNED FOR .15 Z V N N'
TO ATTIC SPRINKLERS GPM/SF OVER THE ENTIRE ATTIC WITH AN
OWNER TO PROVIDE 8"X8" SOFFIT OUTSIDE HOSE ALLOWANCE OF 250 GPM,
AND A MAXIMUM SPRINKLER SPACING OF
130 SO/FT PER SPRINKLER HEAD.
DESIGN AREA 2 - - s €
O , C F C 9
1 ' I ' CEILING - THE ROOM DESIGN METHOD WAS UTILIZED N
T
G
OFFICE 2 FOR THE 2ND FLOOR HYDRAULIC
OFFICE 1 CALCULATION PER NFPA 13 CHAPTER 11
C 9-7 , 'a�X;,9 _xSECTION 11.2.3.3
O u
,s ,a
hoe 18
OR J3 - 2ND FLOOR IS CLASSIFIED AS A LIGHT
-xo
HAZARD OCCUPANCY, .10 GPM/SF OVER
OPEN SPACE THE HYDRAULICALLY MOST DEMANDING � o m
DN EXISTING CEILIN
10' CEILING ROOM PLUS 2 SPRINKLERS. WITH AN w 2 7-
OUTSIDE
OUTSIDE HOSE ALLOWANCE OF 100 GPM. a z
BA
CQ
MAXIMUM SPRINKLER SPACING OF r; � N
Area 2 - 679 Ft' EXTENDED COVERAGE HORIZONTAL d
Design Area No. 2 — LH SIDEWALL NOT TO EXCEED 16 X16 PER
Density 0.10 Area 679 THE MANUFACTURERS CUT SHEET. co N =j
Flow 211 gpm @ 62 psi N M
Ln
Includes 100 gom Hose allowance M c
2ND FLOOR ! M
SCALE:1/4-=1•-0' C
C m
100
coCDdl_c ,°z -
IL
EIrCq
SI
KEY PLAN W
FIRE PROTECTION PLAN 2ND FLOOR&AMC NOT TO SCALE
N SCALE 1„=I— SHEET 2 OF 2
Current Estimated Estimated Max. \lax. Parking Lot Required -
& Area Per Use Employees Seating Capacity Parking
Potential Uses (sq.R.) Per Use Capacity Per Use
Per Use
Existing Carpet Warehouse 5,925.60 1 employees 0 48 2 Total _
(Req.Code=1 per employee+1 company vehicle) I company vehicle I
Existing Carpet Retail Space 1,512.82 n/a 0 48 10 Total - -
(Req.Code=5 per 1,000 sq ft of GLFA)
Flex Space/Food Service Establishment 1,427.92 4 60 48 15(guest)
(Req.Code=15 sq.R.per seat) 839.21(Dining) 2(employee)
(Req.Code=1 per every 4 seats+ 583.71(Kitchen) - -
I per every 2 employees) 17Total _
1
Flex Space/Personal Service 1,378.04 n/a 0 48 5 Total W
(Req.Code=I per 300 sq R of GLFA) •.
Flex Space/Rear Office 730.24 n/a 0 48 2 Total �
(Req.Code=I per 300 sq ft of GLFA) c' -
in �
Flex Space/2nd Floor Office 3.534.SS n!a 0 48 12 Total
(Req.Code=I per 300 sq R of GLFA)
INDICATES NEW CONSTRUCTION OR
RENOVATION
DESIGNCRITERIA:
O WEATHERING SEVEREZONEIS
TERMITES SLIGHT
00 DECAY
"Imm SLIGHT
� DESIGN TEMP. ]6080EGREE GAYS
Lands N/F of Upper SEISMIC SEISMIC 02
Glen Realty inc. �i';( AIR FREEZE INDEX 666
767/215FROST LINE
• t ICE 6 WATER UNDERLAYMENT 2P MIN.
_ ROOD HAZARD—TO BE DET.BY TOWN ZONING DEPT.
65 �y SITE ELEVATION ABOVE SEA LEVEL —FT
2 FIRST FLOOR LIVE LOAD 40 PSF
_ ;y FIRST nc RDEADLOAD 10PBF
'.1 ` SECOND FLOOR INE LOAD 40 PSF
- - "� SECOND FLOOR DEAD LOAD IOPSF
" W ROOF DEAD LOAD I P6F
a2.�IZ• 'la :F'� GROUND SHOW LOAD 60 PSF
.. ISM' J W a N ��y', VAND LOAD SO MPH,]SEC.GUST
o%N d Sheet Index
I.� tPID Name
A-01 MAIN LEVEL
t� j i u s ti ah A-02 MAIN LEVEL SOUTH
39 A-03 MAIN LEVEL(MIDDLE)
I - A-04 MAIN LEVEL NORTH
LL° u°Oi
N A-05 2nd 8 3rd FLOOR PLANS
J A-06 ELEVATION VIEWS
A-07 ELEVATIONS
-
�^ A-08 FOUNDATIONS
i3iip j1 Si (y t(( A-09 FOUNDATIONS
- t,2;.i°• Orta; I y A-10 FRAMING
1 anu"` s a t • -•,r^"'v A-71 FRAMING
00 a 1 1 1 : ;t zf`i L - \/ A-12 SECTIONS
in 8 as i ��; - - �/ A-13 SECTIONS
r- 3 I
�a MD
1 s MILLER DESIGNS
! — {•tit a
` L ti
,,ttom�` l 2�•.5 3t 2
L9 PLANS STATUS:
a�s.. � - '� lPrefrrimryl
CPrd6..q2
W
DRAWN BY: SHALE MILLER
ZIs� /L� P—ECTwra
LLI � lF/
Buy Low Warehouse
LOT LAYOUT IS SCHEMATIC ONLY, REFER Glen Steet/Lafayette St.
Queensbury NY
TO ENVIRONMENTAL DESIGN Warren County NY
PARTNERSHIP LLC (PAGE 1) FOR ACTUAL MAIN LEVEL
oQ
N LOT AREAS, PARKING, CURB CUTS...)
A-01
ENTRANCE t
/ SIGN ' t
X AIN R .. i.
.E.
. - FASIInc .. rur _ 12860FXT
A-O6
18 's
ISTIN6 LIGHT POLE s zs LVL (3)2X
E1 3 PLY 13/i"X14"LVL
1 HEADER
(3)2X6 SNOS EACH END W/ONE
KING SND
F F
- - 8 UP 3 PLY 13/4"X14"LVL
• voce PD HEADER
A 20 MIN X6 STUDS EACH END W/ONE
KIN
` \Y- p00R KING SND
STAIR
7 6X6 N2 YPPT ST
.T. SPACE
.. IN EBSQ66•SD52-WE PO_STS.TO CIA
IN MATERIAL TO FOOD SERVICE
• MIN.8"To MAX F
COLUMN _1
TRA 4CE lI a
3-2X12 42 SPF HEADERS
ENT CE
588.71 sq
STOR.
t.
B<TH�vr R 6X6 P.T.POSTS SET IN CBSQ66-SD52 POST -- .
BASE SET IN ZSE PAD
- - S I+ � -1
-13
COMMON 2 'R i.11-L
BATH
HALL
P ` __ 3
'
1
' � - - •�' '-..., .p,e Q 3-PLY 1 3/4"XI
- �- •� 125"DROPPED LVL CARRY
-
INDIGATE
5 SET CARRY BEAM AND POSTS M RENOVATI AND NEW CONSTRUCTION OR
PSL POST SET REMOVE EXISTING]01575AT STAIR RENOVATION
- IN EXISTING WALL
_ TO SUPPORT ROOF TRIMMER(2X12)REMOVE,RELOCAT,
A
U '"'cET Nvuem
• _ - _ - - / CARRY BEAM 2X6
RANKERS EACH
SIDE SECTION I.IARKER INDICATES PAGE WHERE SECTION CAN BE FOUND
-
OF POST -.
q
(2)PLY 1.7.'X 11.25' _ MD
HEADER W
EACH END ONE KING MILLER DESIGNS
SND
ENTRANCE i.A1,
NOTE: ENTIRE BUILDING IS
PROTECTED BY AN 6X6# POST SET
IN CBSQ66-SD POST
AUTOMATIC SPRINKLER BASE POSTS BE CLAD EXISTING PILASTE
IN MATERIAL TO TE
SYSTEM. DESIGNED BY MIN.8"TO MAY 2"
MANUFACTURER COLUMN
PLANS STATUS:
GLASS ENTRANCE DOORS / `P,``ml
- iPnGrtvnary2
TO BE TEMPERED
G X S TEMPERED O DRAWN BY: SHALE MILLER
FIXED GLASS
aaaEcr wFo
AKLh—F&INTERIOR WALL FRAMING: Buy Low Warehouse
�cb 2X4,2X6 STPs~.7�`;@ 36"D.C.,DBL TO -FLEX S PACE - Glen Steet/Lafayette St.
PLATE SINGLE BASE'±:ATE(P.T.IF IN Queensbury NY
DOOR:T.B.D.BASED ON CONTACT WITH CONCRETE).SOLID Warren County NY
OCCUPANCY OF SPACE BLOCKING AT W ABOVE BASE PLATE, RETAIL _
AT TIME OF RENTAL AND WO.0 ABOVE THAT IF
sNEEr mLe
TING LIGHT APPLICABLE.1/2"DRYWALL
SHEATHING EACH SIDE. MAIN LEVEL SOUTH
3_2.5 POST
1 ,512 . 82 sa ft
6'X 5 TEMPERED v— A_02