RC-000797-2016 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
` Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000797-2016 Date Issued: Friday, August 4, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000797-2016
has been completed.
Tax Map Number: 296.14-2-10
Location: 59 DEVIN CT
Owner: CERRONE BUILDERS,INC.
Applicant: CERRONE BUILDERS, INC.
This structure may be occupied as a: Single Family Dwelling w/FP 1400 s.f.
Garage 400 s.f. By Order of Town Board
Village at Sweet Road,Lot 10 TOWNOF
QQUEENSBUURY�J
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the
Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000797-2016
Tax Map No: 296.14-2-10
Permission is hereby granted to: CERRONE BUILDERS,INC.
For property located at: 59 DEVIN CT
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: CERRONE BUILDERS,INC. Single Family-New $310,000.00
Owner Address: 1589 State Route 9 Total Value $310,000.00
Fort Edward,NY 12828
Contractor or Builder's Name/Address Electrical Inspection Agency
CERRONE BUILDERS,INC.
1589 State Route 9
Fort Edward,NY 12828
Plans&Specifications
Single Family Dwelling w/FP 1400 s.f.
Garage 400 s.f.
Village at Sweet Road,Lot 10
$1,240.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,December 7,2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expirationAdateostemfber
)
Dated at the Town of ueensb J /Ne 7,2016
SIGNED BY: /VJor the Town of Queensbury.
Director of Building&Code Enforcement
MNCIPAL STRUCT RE APPLICATIO �w N, Tice' 'e" nl
Date: 1% ,6 � 2c-607??`
16
p Permit o
Tax Map ID 1 K�'a V 1 8 ARt G
Zone Historic? _ esT F 4 50
ll
Subdivision Name f t- I/ 17 t# B INO&
Project Location JII
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit feels).
Primary Owner(s)
Address
Phone/EmailOjl
Applicant
Address
Phone/Email
Contractor
Address
Phone/Email
Contact Person for Building& Codes Compliance: Phone
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration I'floor sf 211 floor sf Total sf Height
Single Family /G
� ! 0
Two-Family LSOt'
Multi-Family
(#of units
Townhouse
Business Office
Retail-Mercantile
Factory-Industrial
Attached Garage /
(103' 4+) ✓ [� VOO
Other l
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business
Proposed use of building or addition
Source of Heat(circle one) Gas Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances & Chimneys
Are there structures not shown on plot plan? {�
Are there easements on the property? A10
Site Information:
a. Dimensions or acreage of lot 1W Y
b. Is this a corner lot? _Yes ✓ No
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well(circle one) Public Private
e. Sewer or Private Septic System (circle one) Sewe Private
Value of all work to be performed (labor or materials) $ DOC)
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes,local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: !D ��,P/j7� DATE: �l
SIGNATURE: DATE: 11117 I(o
For office use only
Operating Permit Issued: _Yes —No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Fuel Burning Appliance & Chimney Application Office Use Onlv
Received
DATE: L111 7 6 Tax Map ID
TAx MAP ID: E O v Permit No. y4z ZQA
4,
ZONE: D Permit Fee
FEE
OWNER 3 P ONE/E-MAIL
i
ADDRESS
INSTALLER/ PHONE/E-MAIL
BUILDER
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE:
PHONE/E-MAIL BUILDING ADDRESS /
ROOM OF INSTALL: 60,e_jjL1— env, PLANNED INSTALL DATE: l�c°c` . L C>J(7
FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN&
STOVE FINAL INSPECTION ARE
FIREPLACE INSERT REQUIRED.
FIREPLACE,FACTORY BUILT*
NOTE:
MANUFACTURER'S
FIREPLACE,MASONRY
INSTALLATION MANUAL
FURNACE(GARAGE ONLY)
MUST BE AVAILABLE AT
TIME OF INSPECTION
*If factory built provide manufacturer name: Model#:
Listed by: Number:
CHIMNEY INFORMATION
Masonry** (check one) BLOCK _BRICK _STONE
Flue TIE STEEL Size in inches
Material DOUBLE WALL TRIPLE WALL INSULATED
** If non-masonry provide manufacturer name: Model#:
DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or
manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances,
regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises
to perform required inspections.
I HAVE READ AND AGREE TO THE ABOVE:
PRINT NAME: 1 c dirt v DATE: 1111-7116
SIGNATURE: DATE: / 6
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Town,of Queensbury Thomas R. Van Ness
Highway Department Highway Superintendent
742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929
Phone: 518-761-8211
Fax: 518-745-4466 David Duell
Deputy Highway Superintendent
Home: 518-745-0938
DRIVEWAY PERMIT
Date: D
Applicant Name: �?i ! { is f NOV 18 2016
Telephone No.:
TOWN OF QUEENSBURY
Address to be Inspected BUILDING&CODES
Return Address: /� �' E/' (,�• Mzaj /7S-Z-Y
Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes
at the specified location
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action
has been taken:
STEP 1: ( ) Preliminary approval
296.14-2-10 RC-000797-2016
NEED ( ) Slight Swale Cerrone Builders
( ) Deep Swale 59 Devin Court, Lot 10
( ) Level with the road SFD w/FP 1400 s.f., Garage 400 s.f.
O Level with the top of the paved wi
Size culvert pipe to be used(if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36"
Preliminary inspection completed by: Date:
Approval by Highway Supt.: or Deputy Supt.:
Upon completion please resubmit this approval permit for a final approval.
STEP 2: ( ) Final Approval ( ) Rejected
Date:
Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
id
TOWN OF QUEENSBURY
BUILDING & CODES
296.14-2-10 RC-000797-2016
Cerrone Builders —
59 Devin Court, Lot 10 —
SFD w/FP 1400 s.f., Garage 400 s.f.
i 01
1,tvw
I �
11
t
I
i
I
U1
i
REScheck Software Version 4.6.2
Compliance Certificate
296.14-2-10 RC-000797-2016
Project Cerrone Builders Inc Cerrone Builders59 Devin Court, Lot 10
Energy Code: 2015IECC SFD w/FP 1400 SJ., Garage 400 s.f.
Location: Warren County, New York
Construction Type: Single-family
Project Type: New Construction D D
Conditioned Floor Area: 1,400 ft2
Glazing Area 12% NOV ' 2��5
Climate Zone: 6 (8499 HDD)
Permit Date:
Permit Number: TOWN OF QUEENSBURY
BUILDING&CODES
Construction Site: Owner/Agent: eslgner/Contractor:
59 Devin Court Vision Engineering, LLC
Lot 10 206 Glen Street
Queensbury, NY 12804 Suite 56
Glens Falls, NY 12801
(518) 792-9264
;Compliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 223 Your UA: 223
The%Better or worse Than Code Inez reflects how close to compliance the house is based an code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or U-Factor U
Ceiling 1: Raised or Energy Truss 1,400 38.0 0.0 0.025 35
Wall 1: Wood Frame,16"D.C. 1,458 21.0 0.0 0.057 72
Window 1:Vinyl Frame:Double Pane with Low-E 114 0.290 33
Door 1: Front: Solid 20 0.200 4
Door 2: Slider: Glass 40 0.290 12
Door 3: Fire Door: Solid 18 0.140 3
Basement Wall 1:Solid Concrete or Masonry 1,264 0.0 15.0 0.046 57
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth:7.8' _
Basement Sashes: Wood Frame:Double Pane 7 0.340 2
Basement Egress:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.340 5
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES - Page 1 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Y
ik
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed i di has bedesigned to meet the 2015(ECC requirements in
RESche5k Version 4.6.2 and to comply with the mandatory r creme listed ,bee
the REScheck Inspection Checklist.
'
Name-Titletle
° ure
It I cc
if
liv( .
D,p �o.
ROFES S(
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200- DES- Page 2 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
&
103.1, Construction drawings and ❑Complies
103.2 '.documentation demonstrate ❑Does Not
[PRI]' •energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on ❑Not Applicable
Construction documents.
103.1, 'Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 •energy code compliance for
[PR311 ,lighting and mechanical systems. ❑Not Observable
y Systems serving multiple ❑Nat Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, :Heating and cooling equipment is Heating: Heating: ❑Complies
403� -''sized per ACCA Manual S based Btu(hr_ Btu/hr ❑Does Not
[P {on loads calculated per ACCA Cooling: Cooling: ❑No[Observable
Manualj or other methods Btu/hr { Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES - Page 3 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions:
402.1.1 Conditioned basement wall R-_ R- ❑Complies -See the Envelope Assemblies
[F0411 insulation R-value.Where interior R- R- ❑Does Not table for values.
insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable j
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall I4❑Complies
[F0511 insulation installed per "❑Does Not
!,manufacturer's instructions. ❑Not Observable
>-❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO611 insulation depth of burial or ❑Does Not table for values.
0 distance from top of wall. ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[F011]2. to protect exposed exterior ❑Does Not
v insulation and extends a - ❑Not Observable
minimum of 6 in. below grade.
❑Not Applicable j
403.9 '.Snow-and ice-melting system ❑Complies
[F012]' controls installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2'. Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES- Page 4 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section Plans Verified Field Verified
# Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions
&Re .ID
402.1.1, Door U-factor. U-_ U-_ ❑Complies 'See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR11' ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U-_ ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not gable for values.
402.3.3,
402.3.6, ❑Nat Observable .
402.5 ❑Not Applicable j
[FR211
303.1.3 IU-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table. ❑Not Applicable
402.4.1.1 '.Air barrier and thermal barrier ❑Complies
[FR2311 installed per manufacturer's ❑Does Not
;instructions. ❑Not Observable
❑Not Applicable j
402.4.3 'Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
'AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
-400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR1612 'sealed at housing/interior finish ❑Does Not
and labeled to indicate<_2.0 cfm ❑Nat Observable
leakage at 75 Pa.
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 -insulated >= R-8 where duct is []Does Not
>= 3 inches in diameter and >_ ❑Not Observable
R-6 where< 3 inches.Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for<3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR1513 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable j
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR1712 above 105 4F or chilled fluids ❑Does Not
below 55 QF are insulated to zR- ❑Not Observable
3.
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR2411 piping. []Does Not
,v ❑Not Observable
-;❑Not Applicable j
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. []Does Not
❑Nat Observable
❑Nat Applicable j
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable I
❑Not Applicable j
11 High Impact(Tier 1) j 2 Medium Impact(Tier 2) 3' Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Reportdate: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200- DES - Page 5 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Additional Comments/Assumptions:
11 High Impact(Tier 1) Medium Impact(Tier 2) 3 1 low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES - Page 6 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section Plans Verified Field Verified
# Insulation Inspection . Value Value Complies? Comments/Assumptions
& Req ID
303.1 All installed insulation is labeled ! ❑Complies
[IN13]' :or the installed R-values ❑Does Not
'provided. ❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R-_ ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1h of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 -.wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN311 ..exterior,the exterior insulation
:requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN411 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 -DES - Page 7 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section
Plans Verified
#
Final Inspection Provisions Field Verified
Value Value complies? Comments/Assumptions
& Re .ID
402.1.1, '.Ceiling insulation R-value R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood F-1Wood ❑Does Not table for values.
402.2.2, j❑ Steel ❑ Steel j❑Not Observable
402.2.6
[Fill' ❑Not Applicable j
303.1.1.1,,Ceiling insulation installed per - ❑Complies ;
303,2 manufacturer's instructions. ❑Does Not
[F1211 Blown insulation marked every
300 ft'. ❑Not Observable
❑Not Applicable
Pte. Vented attics with air permeable ❑Complies
insulation include baffle adjacent ❑Does Not
:to soffit and eave vents that
extends over insulation. -.❑Nat Observable
❑Not Applicable
402.2.4 (Attic access hatch and door R-_ R-_ ❑Complies
[F1311 insulation >_R-value of the ❑Does Not
'adjacent assembly. ❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50=_ ACH 50 =_ ❑Complies
[FI17]1 �ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. - []Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 ! cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ! ft2 - ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests,verification may need to ;❑Not Applicable
!occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]1 determine air leakage with ft2 ❑Does Not
either: Rough-in test:Total ❑Not Observable
leakage measured with a
pressure differential of 0.1 inch !❑Not Applicable j
w.g,across the system including j
:the manufacturer's air handler
enclosure if installed at time of
;test.Postconstruction test:Total
:leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
;including the manufacturer's air
handler enclosure. -
403.3.2.1 Air handler leakage designated ❑Complies
[FI2411 by manufacturer at<=2%of ❑Does Not
design airflow. ❑Not Observable
❑Not Applicable j
403.1.1 ,Programmable thermostats ❑Complies
[1`19]2 ` installed for control of primary ❑Does Not
heating and cooling systems and ❑Not Observable
1. ..
.;initially set by manufacturer to ❑Not Applicable
Observable
j
code specifications. _____
403. Heat pump thermostat installed ❑Complies
[F11012'" on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable j
403.5.1 'Circulating service hot water ❑Complies
[Flll]2 '.systems have automatic or ❑Does Not
',accessible manual controls. ❑Not Observable
-. ❑Not Applicable
11 High Impact(Tier 1) 12' Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES - Page 8 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section Plans Verified Field Verified
# Final inspection Provisions Value Value Complies? Comments
/Assumptions
Req.ID
&
403.6.1 All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed !:❑Does Not
HVAC equipment meet efficacy
and airflow limits. `:❑Not Observable
❑Not Applicable j
403.2 Hot water boilers supplying heat ❑Complies
[F[26]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback ❑Not Observable
control to lower boiler water
temperature based on outdoor ❑Not Applicable
-temperature.
403 S l,la Heated water circulation systems ❑Complies
[112812 +have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- - ❑Not Applicable
syphon circulation systems are
not present.Controls for -
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403 5.14' Electric heat trace systems ❑Complies
[FI29]2 comply with IEEE 515.1 or UL - ❑Does Not
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the ❑Not Applicable j
desired water temperature in the
piping. _
403.5.2 Water distribution systems that ❑Complies
[F13012 have recirculation pumps that ❑Does Not
pump water from a heated water
[-]Not Observable
supply pipe back to the heated ❑Not Applicable
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F. _
403.5.4 Drain water heat recovery units ❑Complies
(F13112 tested in accordance with CSA ❑Does Not
355.1. Potable water-side ❑Not Observable
pressure loss of drain water heat
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers.Potable water-
side pressure loss of drain water
heat recovery units <2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not f
'.fixtures have high efficacy lamps. ❑Not Observable
Does not apply to low-voltage ❑Not Applicable j
lighting.
404.1.1 Fuel gas lighting systems have ❑Complies
[F12313 no continuous pilot light. ❑Does Not
4d� ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200-DES- Page 9 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
Section plans Verified Fiel�Verifled# Final Inspection Provisions Value Complies? Comments/Assumptions
&
Req ID
401.3 :Compliance certificate posted. ❑Complies
[F17[2 ❑Does Not
❑Nat Observable
❑Nat Applicable
303.3 Manufacturer manuals for ❑Complies
[Fi18]3 :mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/17/16
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1200 - DES- Page 10 of 10
Cerrone Devin Court Lot 10\1200 Rescheck.rck
2015 IECC Energy
Efficiency Certificate
insulation Rating R.Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.29
Door 0.29
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
Manual S Compliance Report Job:
Date: Dec 06,2016
Entire House By:
CERRONE P&H
QUEENSBURY,NY 12804 `��(/��� 461)U,
Project • •
For: 59 devin
queensbury, NY 12804
Cooling Equipment
Design Conditions
Outdoor design DB: 85.0°F Sensible gain: 11647 Btuh Entering coil DB: 75.0°F
Outdoor design WB: 71.0°F Latent gain: 1198 Btuh Entering coil WB: 62.5°F
Indoor design DB: 75.0°F Total gain: 12845 Btuh
Indoor RH: 50% Estimated airflow: 547 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Split AC
Manufacturer: York Model: YCJF18S41S1+BC**A2(6,9)24++TD
Actual airflow: 547 cfm
Sensible capacity: 0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0°F Heat loss: 53212 Btuh Entering coil DB: 70.0°F
Indoor design DB: 70.0'F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9X060B12MP11
Actual airflow: 547 cfm
Output capacity: 57000 Btuh 107% of load Temp. rise: 50 'F
ra
00 F ONIOiine
N33no 30 NMO.L
F7,,,7
, /s 3-Q
Meets are all requirements ofACCA Manual S. 3 a
R ] G` �� 2016Dec 06 16:47:77
wrightsofC Right-Suite®Universal 2077 77.0.16 RSU25116 ` Page 1
.SCA ...s\scott.lengmonhy\Documents\York\59DEVIN.mp Calc=MJB Fmnt Dcorfaces: N
Residential Plans E _ —r Review Form Form
RPER 1
ACCP.® for HVAC System
•n (Loads, Eauioment. 15 Mar 09
acadm.yono-aa,nuA„a�
Header Information
Contractor: CERRONE P&H REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes ❑ No ❑
Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes ❑ No ❑
OEM performance data(heating,cooling,blower): Yes ❑ No ❑
Building plan A Manual D Friction Rate Worksheet: Yes ❑ No ❑
Duct distribution sketch: Yes ❑ No E]Home address(Street or Lot#,Block,Subdivision): , Entire House
HVAC •A• • •
Design Conditions Buildinq Construction Information
Winter Design Conditions Building
Outdoor temperature: -4 -F Orientation: Front Door faces North
Indoor temperature: 70 =F North,East,West,South,Northeast,Northwest,Southeast,Southwest
Total heat loss: 53212 Btuh Number of bedrooms: 0
Conditioned Floor area: 2718 ft'
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 °F Windows Roof
Grains difference: 28 gr/Ib @60p/o RH Eave overhang depth: 0 ft
Sensible heal gain: 12941 Btuh Internal shade: none
Latent heal gain: 1331 Btuh Blinds,drepea,etc. OapM vend.
Total heat gain: 14272 Btuh Number of skylights: 0
HVAC EQUIPMENT SELECTION (IRC M1401.3)
Heating Equipment Data Coolinq Equipment Data Blower Data
Equipment type: Gas furnace E%igment type: SpIRAC Heating cfm: 547
umace,Heatpump,Boller,etc. it ond6loner,Heat pump,etc. Cooling cfm: 547
Model: York Model: York Static pressure: 0 in H2O
TM9X060B12MP11 YCJF18S41S1+BC"A2(6,9)24++TD fan's ret ed eztemai static pressure for
Heating output capacity: 57Q00 Btuh Total cooling capacity: 0 Btuh deelgn airflow
Heat pumps-capacity at winter design on door conditions
Sensible cooling capacity: q Btuh
Aux heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
HVAC DUCT DISTRIBUTION SYSTEM • 1
Design airflow: 547 cfm Longest supply duct: 0 ft Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct:
Total device pressure losses: 0 in H2O Total effective length(TEL): 0 It
Available static pressure(ASP): 0 it H2O Friction rate:
rel lon Rate=ASP+(TFL a 10 Q) in/100fl Branch duct: Sheet metal
I declare the load calculation,equipment equipment selection and duct
• -• above. •- • - -•- e - • be subject todesign review and verification.
Contractor's printed name:
Contractor's signature: Date:
Reserved for County,Town Municipality orAuthority having jurisdiction
'Home qualifies for MJ1AE Form based on Abridged Edition Checklist
+I+ wrightSOfr Right-Supe®universal 2017 17.0.16 RSU25116
y Project SummarJob:
{ ' 1 Date: Dec 06,2016
Entire House By:
CERRONEP&H
QUEENSBURY, NY 12804
Promect Information
For: 59 devin
queensbury, NY 12804
Notes:
Design • •
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db -4 OF Outside db 85 OF
Inside db 70 OF Inside db 75 OF
Design TO 74 OF Design TO 10 OF
Daily range M
Relative humidity 50 %
Moisture difference 28 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 53212 Btuh Structure 11647 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 53212 Btuh Use manufacturer's data n
Rate/swingg multipplier 0.90
Infiltration Equipmentsensibleload 10482 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1198 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft') 2718 2718 Equipment latent load 1198 Btuh
Volume(ft') 24222 24222
Air chan�gges/hour 0.32 0.16 Equipment total load 11680 Btuh
Equiv.AN (cfm) 129 65 Req, total capacity at 0.70 SHR 1.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade ADP
Model TM9X060B12MP11 Cond YCJF18S41S1
AHRI ref 2008693 Coil BC**A2(6,9)24++TD
AHRI ref 5664015
Efficiency 95.5AFUE Efficiency 11.0 EER, 14 SEER
Heating input 60000 Btuh Sensible cooling 11480 Btuh
Heating output 57000 Btuh Latent cooling 4920 Btuh
Temperature rise 96 OF Total cooling 16400 Btuh
Actual air flow 547 cfm Actual air flow 547 cfm
Air flow factor 0.010 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htSOft' 2016-Dec-0616:41:17
AC g Right-ork\59 universal 2017 17.0.16 RS rant D Page 1
...slscott.langewonhy\Documents\York\59 DEVIN.rup Calc=MJB Front Door faces: N
AED Assessment Job:
Date: Dec 06,2016
Entire House By:
CERRONEP&H
QUEENSBURY, NY 12804
Project
For: 59 devin
queensbury, NY 12804
Design C • • •
Location: Indoor: Heating Cooling
Glens Falls AP, NY, US Indoor temperature(°F) 70 75
Elevation: 335 ft Design TD (°F) 74 10
Latitude: 43'N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.8 27.6
Dry bulb (°F) -4 85 Infiltration:
Daily range (°F) - 20 ( M )
Wet bulb (°F) - 71
Wind speed (mph) 15.0 7.5
Test forAdequate Exposure
Hourly Glazing Load
8.000-
7,000-
6,000--
5,000--
0
,0007,0006,0005,0000
4,000--
N
N
3,000
2,000
1,000--
0
,0000
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
/ Hourly / Average / AED limit
Maximum hourly glazing load exceeds average by 34.2%.
House does not have adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 227 Btuh (PFG - 1.3*AFG)
htSofY
2016-Dec-06 16 41
wri
9 Right-Buda®Universa1201717.0.16 RSU25116 Page 1
ACCN ...s\scott.langeworthy\Documents\York\59DEVIN.rup Catc=MJB Front Door faces: N
Right-J® Worksheet Job:
Entire House Date: Dec 06,2016
CERRONEP&H By:
QUEENSBURY NY 12804
1 Room name Entire House Room1
2 Exposed wall 322.0 ft 0 It
3 Room height 9.0 ft d 9.0 It heat/cool
4 Roan dimensions 0 x 4.0 ft
5 Room area 2718.0 ft' 0 ft'
Ty Construction U-value Or HTM Area (ftp Load Area (ft-) Load
number (BtulVft;°F) (Btulvft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh)
Heat FCol Gross N/P/S Heat Cad Gross N/P/S Heat Cod
6 1q/ 12F4sw 0.053 n 3.92 0.41 828 756 2965 309 0 0 0 0
�-G 1Dc2ov 0.570 n 4218 16.38 72 0 3037 1178 0 0 0 0
w 15811-8wc-6 0.055 n 3.48 0.10 90 90 313 9 0 0 0 0
12F4sw 0.053 a 3.92 Q41 531 527 2087 215 0 0 0 0
11 1D-c2ov 0.570 a 4218 58.17 4 0 169 233 0 0 0 0
lQ! 12F45w 0.053 s 3.92 0.41 918 828 3247 338 0 0 0 0
��CD 1D-C20v 0.570 s 42.18 30.67 48 0 2025 1467 0 0 0 0
11P0 0.290 s 21.46 6.23 42 42 901 262 0 0 0 0
12F4sw 0.053 w 3.92 0.41 495 463 1816 189 0 0 0 0
1D-c2ov 0.570 w 42.18 58.17 32 0 1350 1881 0 0 0 0
w 15811-8wc-6 0.055 w 3.48 0.10 36 36 125 4 0 0 0 0
C 16B-38W 0.028 - 1.92 1.17 1441 1441 2772 1686 0 0 0 0
F 19A-0bswp 0.295 - 8.20 1.11 1280 1280 10497 1418 0 0 0 0
F 19A-Obswp 0.295 - 8.20 1.11 1398 1398 11465 1549 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 40 40 74 0 0 0 0 0
6 c)AED excursion 2271 10
Envelope loss/gan 42823 10945 0 0
12 a) Infiltration 10389 702 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
subtotal(lines 6 to 13) 53212 11647 0 0
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtota 53212 11647 0 0
15 Duct loads 0% 0% 0 0 -0% 0% 0 0
Told mom load 53212 11647 0 0
Air required(cfm) 547 547 1 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.�G`A Art- wrightsoft' RighiSude®Universal 2017 6 RSU251 2016-Dec-0616:41:17
...s\scott.langewonhy\Documents\York\59 DEVIN.rup Cele lc==MDoor Front Door faces: N Page 1
Right-J® Worksheet Job:
Entire House Date: Dec 06, 2016
CERRONEP&H By:
QUEENSBURY,NV 12804
1 Room name WIC MASTER BATH
2 Exposed wall 14.0 ft 7.0 It
3 Room height 9.0 It heaVcool 9.0 ft heatfccol
4 Room dimensions 10.0 x 4.0 ft 10.0 x 7.0 it
5 Room area 40.0 W 70.0 W
Ty I Construction U-value Or HIM Area (ftp Load Area W) Load
number (Bb.10MF) (BtulVryj or perimeter (It) (Bluh) a perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
812F-4sw 0.053 n 3.92 0.41 0 0 0 0 0 0 0 0
1D-c2ov 0.570 n 4218 16.36 0 0 0 0 0 0 0 0
W 15311-8wc6 0.055 n 3.48 0.10 90 90 313 9 0 0 0 0
12F4sw 0.053 a 3.92 0.41 0 0 0 0 0 0 0 0
11 1Dc2ov 0.570 a 4218 5317 0 0 0 0 0 0 0 0
t12FAsw 0.053 s 3.92 0.41 0 0 0 0 0 0 0 0
GD 1Dc2ov 0.570 s 4218 30.57 0 0 0 0 0 0 0 0
11P0 0.290 s 21.46 6.23 0 0 0 0 0 0 0 0
12F4sw 0.053 w 3.92 0.41 0 0 0 0 63 55 218 22
Y-G 1Dc2ov 0.570 w 42.18 58.17 0 0 0 0 8 0 337 465
W 15811-8wo-6 0.055 w 3.48 0.10 36 36 125 4 0 0 0 0
C 16B38ad Q028 - 1.92 1.17 0 0 0 0 0 0 0 0
F 19A-Obswp 0.295 - 8.20 1.11 0 0 0 0 70 70 574 78
F 19A6bswp 0.295 - 8.20 1.11 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 40 40 74 0 0 0 0 0
e c)AEC)excursion -2 185
Envelope loss/gain 512 11 1127 750
12 a) Infiltration 155 10 233 16
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants(31 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 667 21 1360 766
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redlsldbullal 0 0 0 0
14 Subtotal 887 21 1380 788
15 Duct loads -0% 0% 0 0 -0% 0% 0 0
Total man load 667 21 1360 766
Air required(cfm) 1 7 1 1 14 36
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
c4F wrl htSoft• 2016-Dec-0616:41:17
. M 9 RightYork\5DUniversal 201717.0.16 FmntD Paget
...s\scott.langeworthy\Documents\York\59 DEVIN.rup CeIc=MJB Front Door feces: N
Right-J® Worksheet Job:
Entire House Date: Dec 06,2016
CERRONE P&H By.
QUEENSBURY,NY 12804
1 Roan name MASTER BED MUD
2 Exposed wall 26.0 it 8.0 It
3 Roan height 9.0 It heat/cool 9.0 it heatf000l
4 Roan dimensions 13.0 x 13.0 it 8.0 x 11.0 ft
Roan 5 Ron area 169.0 ft' 88.0 ft'
Ty Constriction U-value Or HTM Area (ftp Load Am (ft) Load
number (BtubfftMF) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
HeatCod Gross N/P/S Heat Cod Gross N/P/S Heat cod
6 l4/ 12F4sw 0.053 n 3.92 0.41 0 0 0 0 0 0 0 0
�--r; 1Dc2<1v 0.570 n 4218 16.38 0 0 0 0 0 0 0 0
w 15811-0m6 0.055 n 3.46 0.10 0 0 0 0 0 0 0 0
12F4sw 0.053 a 3.92 0.41 0 0 0 0 0 0 0 0
11 1Dc2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
1q/ 12F4sw 0.053 s 3.92 0.41 117 117 459 48 72 51 200 21
1Dc2w 0.570 s 42.18 30.57 0 0 0 0 0 0 0 0
11P0 0.290 s 21.46 6.23 0 0 0 0 21 21 451 131
lM 12F4sw 0.053 w 3.92 0.41 117 93 365 38 0 0 0 0
�-C 1D-c2ov 0.570 w 42.18 58.17 24 0 1012 1396 0 0 0 0
w 15811-8wc6 0.055 w 3.48 0.10 0 0 0 0 0 0 0 0
c 18B38ad 0.028 - 1.92 1.17 0 0 0 0 0 0 0 0
F 19A-Obswp 0.295 - 8.20 1.11 169 169 1386 187 88 88 722 98
F 19A-Obswp 0.295 - 8.20 1.11 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
61 c)AED excursion 556 -24
Envelope loss/gen 3222 2225 1372 226
12 a) Infiltration 864 58 256 18
b) Raxn ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 4086 2283 1638 244
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistnbulion 0 0 0 0
14 Subtotal 4086 2283 1638 244
15 Duct leads 1 -0% 0%1 0 0 -0% 0% 0 0
Total room load 4086 2283 1638 244
Air required(cfm) 42 107 17 11
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c wri htsofY 2016-Dec-0616:41:17
. h 9 Right-Suite®Universal 201717.0.16 RSU25116 Page 3
...slscott.langewonhy\Documents\York\59DEVIN.mp Calc=MJB Front Doorfaces: N
Right-J® Worksheet Job:
Entire House Date: Dec 06,2016
CERRONEP&H By:
QUEENSBURY,NY 12804
1 Room name STAIRS BED 2
2 Exposed wall 3.0 It 25.0 ft
3 Room height 9.0 It heat/cool 9.0 ft heat/cod
4 Room dimensions 3.0 x 12.0 ft 120 x 12.0 It
5 Room arm 38.0 ft° 144.0 W
Ty Construction U-value Or HTM Area (ftp Load Area (ft2) Load
number (BtuIVft;°F) (Stubtti a perimeter (ft) (Bluh) a perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 l4/ 12F-0sw 0.053 n 3.92 0.41 27 27 106 11 106 96 377 39
�-G lDC20v 0.670 n 4218 16.36 0 0 0 0 12 0 506 196
w 151311-Bwc-6 0.055 n 3.48 0.10 0 0 0 0 0 0 0 0
12F4sw 0.053 a 3.92 0.41 0 0 0 0 108 108 424 44
11 1Dc2ov 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
1qJ 12F4sw 0.053 s 3.92 0.41 0 0 0 0 9 9 35 4
L�-CD 1Dc2ov 0.570 s 4218 30.57 0 0 0 0 0 0 0 0
11P0 0.290 5 21.46 6.23 0 0 0 0 0 0 0 0
12F4sw 0.053 w 3.92 0.41 0 0 0 0 0 0 0 0
1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
w 15B11-8M-S 0.055 w 3.48 0.10 0 0 0 0 0 0 0 0
C 16B38ad 0.025 - 1.92 1.17 0 0 0 0 24 24 46 28
F 19A-0bswp 0.295 - 8.20 1.11 36 36 295 40 144 144 1181 160
F 19A-Obswp 0.295 - 8.20 1.11 0 0 0 0 0 0 0 0
F 21A-241 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion _5 -47
Envelope loss/gain 401 46 1 2569 424
12 a) Infiltration 100 7 831 56
b) Roan ventilation 0 0 0 0
13 Internal gains: Oauparrts 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 501 53 3399 480
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 501 53 3399 480
15 Duct loads -0% 0°/ 0 0 -0%1 0% 0 0
Total roan load 501 53 1 3399 480
Air required(cfm) 5 2 35 23
J, Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.AGF►. -141j- wrightsoft- Right-Sulte®Universal 2017 17.0.16 RSU25116 2016-Dec-06 16:41 age 4
...s\scott.langmorthy\Documents\York\59 DEVIN.mp Calc-MJ8 Front Door faces: N
Right-J® Worksheet Job:
Entire House Date: Dec 06,2016
CERRONE P&H By:
QUEENSBURY,NY 12804
1 Room name BATH OFFICE
2 Exposed wall 5.0 If 20.0 It
3 Room height 9.0 ft heaUccd 9.0 ft heat/cool
4 Room dimensions 9.0 x 5.0 It 12.0 x 8.0 It
5 Room area 45.0 ft2 98.0 W
Ty Construction U-value Or HTM Arm (112) toad Arm (ft2) toad
number (Btuhlft;*F) (Btulvft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cad Grass N/P/S Heat Cod Gross N/PIS Heat Cod
6 W 12F-4sw 0.053 n 3.92 0.41 0 0 0 0 0 0 0 0
�G 1Dc2w 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
w 15811-8wc-0 0.055 n 3.48 0.10 0 0 0 0 0 0 0 0
12F-4sw 0.053 a 3.92 0.41 45 45 176 18 72 72 282 29
11 1Dc2ov 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
Y// 12F-"w 0.053 s 3.92 0.41 0 0 0 0 108 84 329 34
I�-(D; 1Dc2ov 0.570 5 42.18 30.57 0 0 0 0 24 0 1012 734
11P0 0.290 5 21.46 6.23 0 0 0 0 0 0 0 0
12F4sw 0.053 w 3.92 0.41 0 0 0 0 0 0 0 0
1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
w 15811-8wc-6 0.055 w 3.48 0.10 0 0 0 0 0 0 0 0
C 1613-38ad 0.026 - 1.92 1.17 5 5 10 6 8 8 15 9
F 19A-0bswp 0.295 - 8.20 1.11 45 45 369 50 96 96 787 106
F 184-0bswp 0.295 - 8.20 1.11 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
61 c)AED excursion -8 129
Envelope loss/gain 555 67 2427 1042
12 a) Infiltration 166 11 665 45
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 721 78 3091 1087
Less extenlal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 721 78 3091 1087
1151 Duct bads -0% 0% 0 0 -0% 0% 0 0
Trial roan load 721 78 3091 1087
Air required(cfm) 7 4 32 51
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Pk wrightsofr2016-Dec-0616:41:17
Right-Suite®Universal 2017 17.0.16 RSU25116 Page 5
...s\scott.langeworthy\DocumentslYork\59 DEVIN.rup Calc=MJ8 Front Door faces: N
Right-JO Worksheet Job:
Entire House Date: Dec 06,2016
CERRONEP&H By:
OUEENSBURY,NY 12804
1 Roan dame KITCHEN GREAT Rcam16
2 Exposed well 520 ft 1620 fl
3 Room height 9.0 ft healfccol 9.0 It heat/cool
4 Roan dimensions 1.0 x 632.0 it 1.0 x 1398.0 ft
5 Roon arm 632.0 ft- 1398.0 ft-
Ty Constriction U-value Or HTM Area (ftp Load Area (ill Load
number (Btuh/ftMF) (Btutvft.) a perimeter (H) (Btuh) or perimeter (ft) (Btuh)
HeatCod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 l4/ 12F45w 0.053 n 3.92 0.41 243 2(Y7 812 84 450 426 1671 174
�-G 1Dc2w 0.570 n 42.18 18.36 36 0 1518 589 24 0 1012 393
w 15811-8wc-6 0.055 n 3.48 0.10 0 0 0 0 0 0 0 0
12F45w 0.053 a 3.92 0.41 27 23 90 9 279 279 1094 114
11 113c2or 0.570 a 4218 58.17 4 0 169 233 0 0 0 0
lt! 12F4sw 0.053 s 3.92 0.41 162 129 506 53 450 438 1718 179
I�-(D; iDc2ov 0.570 s 4218 30.57 12 0 506 367 12 0 506 367
11P0 0.290 s 21.46 6.23 21 21 451 131 0 0 0 0
Y-0
12F4sw 0.053 w 3.92 0.41 36 36 141 15 279 279 1094 114
Y-C 1Dc2w 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
w 15B114�wcb 0.055 w 3.48 0.10 0 0 0 0 0 0 0 0
C 16B38ad 0.026 - 1.92 1.17 6 6 12 7 1398 1398 2690 1636
F 19A-0bswp 0.295 - 8.20 1.11 632 632 5183 700 0 0 0 0
F 19.4-ftwp 0.295 - 8.20 1.11 0 0 0 0 1398 1398 11465 1549
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
61 c)AED excursion qp4 _354
Envelope loss/gain 9388 1984 21250 4171
12 a) Infiltration 1728 117 5383 364
b) Rahn ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 11115 2101 26633 4535
Less external load 0 0 0 0
Less trarssfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 11115 2101 28833 4535
15 Duct loads -0% 00/0 0 0 -0% 0% 0 0
Total room load 11115 2101 28633 4535
Air required(cfm) 114 99 274 213
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrightsoft- Right-SuBe®Universal 2017 17.0.A6 RSU25116 2016-Dec-061:41:176
...s\scott.langeworhy\Documents\York\59DEVIN.mp Calc=1038 Front Dcarfaces: N Page
Aug. 14. 2011JJ 2: 16P MDIA No. 0252 P. 4/4
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
td� ty mt that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: Date:
Cerrone Bldrs 08/01/2017
Occupant Location:
Same Lot 10#59 Devin Court
Occupancy: .Ingle Family Dwg, Queensbury,Warren Co. NY
Applicant:
Cerrone Builders
Gianni Cerrone
1589 Rt 9
L Fort Edward, NY 12828
J
No. Joseph A.Holmes
- - .1.453L4208065EL :_ - -- - - - - - -• - - - -
Equipment:
200 -Amp. Service Equipment; 4/0-Service Cond"uc-tor 38-Switches; 48 -Receptacles; 44- Fixtures; 1 - Bunter,
Wiring&Control:2-Vent Fans; 6-Smoke Detectors; 10-Arc Fault Breakers
This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This cerdrlcate applies only to the use,occupancy and
above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. upon a change In me use,occupancy or ownership
inspection, No warranty is expressed or implied 08 to the mechanical safety,am- of the property indicated above,this ce/tifie to shall be immediately null and void.
Clancy or fitness of the Equipment for any particular purpose. This certificate shell In the event chat this certificate becomes invalid Wed upon the above conditions,
be valid for a Wod of one year from the above noted data. Should the electrical this certificate may be revalidated upon rainspection by Middle Deparlmant
system m which this certificate applies be altered in anyway Including but not limit- Inspection Agency,Inc. An application for inspection must be submined to Middle
ed to.the introduction of additional alettriral equipment and/or the replacement of Department Inspection Agency. Inc. to Inl(Iate the inspection and revalidation
any of the components installed as of the above noted date•this certificate shall be process. A fee will be charged for this service.
p ECE5VC
AUG
16 2017 D
TOWN OF QUEENSBURY
BUILDING&CODES