Loading...
CC-000241-2015 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000241-2015 Date Issued: Friday, April 15, 2016 This is to certify that work requested to be done as shown by Permit Number CC-000241-2015 has been completed. Tax Map Number: 296.15-1-2 Location: 100 GENTRY LN Owner: Schermerhorn Properties Applicant: Schermerhorn Properties This structure may be occupied as a: Cottage Hill Project Bldg. 9 8 Apts w/garages & fireplaces By Order of Town Board TOWN OF QUEENS SBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 QL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000241-2015 6P EGA- Tax Map No: 296.15-1-2 REVISED r Permission is hereby granted to: Schermerhom Properties REVISE D For property located at: 100 GENTRY LN LN in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Address: 536 BAY RD Multi-Family-New $100,000.00 Queensbury,NY 12804 Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Schermerhom Properties 536 BAY RD Queensbury,NY 12804 Plans&Specifications 8 Apts w/garages&fireplaces PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,May I,2716 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the TownQueens j4T u 27,2014 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140170 Application Number: A20140170 Tax Map No: 523400-296-015-0001-002-000-0000 Permission is hereby granted to: SCH COTTAGE HILL, LLC For property located at: Gentry Ln in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCH COTTAGE HILL,LLC Apartments $100,000.00 536 BAY Rd Fireplace QUEENSBURY NY 12804-0000 Garage Attached Total Value $100,000.00 Contractor or Builders Name/Address Electrical Inspection Agency Plans&Specifications 2014-170 BLDG#9 100 Gentry Lane Apartment Bldg- 8 units for a total of 14,179 sq ft w/8 garages& 8 fireplaces $3,261.17 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,May 27,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town f Quebury Wu y 27,2014 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement 0 ----- F _---------------___________.........__------------------- _ ,.. ___�_.:-_� . oto OFFICE USE ONLY 14 214 py ; TAX MAP NO. PERMIT NO. ; ENSB�RY ; FEES: PERMIT as 0_11/n RECREATION ENGINEERING N 01NG&CODES (If applicable) BUILD ; ------------..... . . . . PRINCIPAL STRUCTURE. APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: reEX OWNER: tslw" -G ADDRESS: 53(o 93A-4 '�U11E Z ADDRESS: . ��-ao7151 NX 1 eat PHONE NO PHONE NOS. FWoj� 1 1tAI CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: A , P' 614E: 51�'CD�6-IgDS LOCATION OF PROPERTY: O UIW11461 2* !3 ('� � i.Aag 6D7MM& 1XL- HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? 117 YES ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z I__APPLY TO YOUR I- p Cn CEJ � F w PROJECT o OMM w p LL O U_ =U. O Q LL c7 W O J d i C1 I- H O F- W z z ¢ Q ern NU) OU_ I- LL axas SINGLE FAMILY TWO-FAMILY 'A MULTI-FAMILY it riD .,i mi yyf�'1q /jAI &, I'II (NO.of UNITS 1 l r , J ` �T '10 TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queensbury* Community Development Office *742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL—NAME�,.�OF BUSINESS: Garn%CM jAIV. _MtA)rlNot�s W0V� ESTIMATED CONSTRUCTION COST: .0150 FUEL TYPE: t4kr, 6.S HEAT TYPE: *HOW MANY FIREPLACE(S):_o AND/OR WOODSTOVES(S):� ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? �El� IS THIS A HISTORIC SITE? IAV PROPOSED USE OF BUILDING OR ADDITION: -h0u Aj1 qU5e_ j fL C— ►+ 't�`�� ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 9Q ARE THERE EASEMENTS ON PROPERTY? 6�fVN "Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and a�g`ree above. IA&&V4t- eSigned &AAW44► 7 Director of Building & Codes: 761-8256 (for questions regarding Building Permits. construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Offl "Use On a N� � u ---- Town of Queensbury Building & Codes R4Sc�.II eo. ` Veils: p1AY FUEL BURNING APPLIANCE &CHIMNEY APPLICATION P tN .: Pe it FfFNN Ot OUEENSB BuiLDIIQL�`"`cvv _ Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit pursuant to the NYS Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances,regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. Important Note To Applicant: Rough-in and Final Inspections Are Required: Date �41e W�' Owner Installer/Builder ��aYYJ Address F-CAP Address 8� iiR Phone Gr%�-74q&' Yo`f Phone Location of proposed construction and/or installation: &M-TS d'�IU. -tb(d11�Kt�!'Se MM Contact Person for Building&Codes Compliance: Irl} hrt h"M"Awwa Subdivision Name: l Lk' Fuel Burning Appliance Information Wood Coal Pellet Gas Oil Stove Fireplace Insert Fireplace,factory built' V Fireplace,Masonry Furnace,(Garage Only) If Factory Built,Please Provide: Manufacturer Name: Model No. Listed By: Number. Chimney Information Masonry" ✓checkone Block Brick Stone Flue ✓check one _Tile _Steel Size in Inches Material ✓check one Double Wall _Triple Wall Insulated Direct Vent _Chimney Liner If Non-Masonry,please provide: Manufacturer Name: Model No. Signatures: 1+_. Print Name: ^�+�+ Signature: Date: ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)751-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000241-20 1 5 Case Module: Permit Inspection Date: 04/15/2016 Inspection Status: Passed Inspector. Mike Palmer Inspection Type: OCC-Inspections Job Address: 100 GENTRY LN LN Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Applicant [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Contractor [Schermerhorn Properties] Granted Permission [Sch Cottage Hill,LLC] Checklist Item Passed Comments Smoke Detectors FC907-Smoke Detectors FC907 YES Fire Marshal-Fire Marshal YES Exit Enclosure FC1020&FC1029-Exit Enclosure FC1020&FC1029 YES Truss ID Signage FC505.3-TRUSS ID SIGNAGE FC505.3 YES Locks and Latches FC1008&FC1029.2-Locks and Latches FC1008 YES &FC1029.2 Sprinkler System Annual-Sprinkler System Annual YES Exit Access FC1014&FC1029-Exit Access FC1014&FC1029 YES Clearance to Sprinkler/Ceiling FC315.2.1 18"/24"-Clearance to YES Sprinkler/Ceiling FC315.2.1 18"/24" F.D.Signage-FC510-F.D. Signage-FC510 YES Sprinkler FDC-Sprinkler FDC YES Occupancy Cycle-Occupancy Cycle NO R CO Detectors FC610-CO Detectors FC610 YES Interior Finishes FC803-804-Interior Finishes FC803-804 YES Exit Discharge FC1024&FC1029-Exit Discharge FC1024&FC1029 YES Electrical Wiring Enclosed/Labeled FC605.3.1 -Electrical Wiring YES Enclosed/Labeled FC605.3.1 Combustibles in Equipment Rooms FC 315.2.3-Combustibles in YES Equipment Rooms FC 315.2.3 Clearance to Electrical FC 605.3-Clearance to Electrical FC 605.3 YES Denny Palmer,Mike(Inspector) Apr 15,2016����,m�.A�. �,p,xiw,�n.�„.� �...,.,��,..,,....�uA,,w,,, Page(19) Inspection Form _ Town of Queensbury Fire Marshal O Periodic Inspection Date:911 fiit Time: r 742 Bay Road,Queensbury NY 12804 ®Re-Inspection y L�1 518 761 8206/518 761 8205 CO Inspection Permit#: Fire.Marshals Representative (MJ Palmer Business Name: &�rn°^�•�--I '`'""''' f Location: i0 U GC. LGtie.: NJ GK Stillman Contact: +vw7 Type of Inspection N/A Yes No EXITS: Exit Access FC 1014& FC1029 k NOTES Exit Enclosure FC 1020& FC1029 Exit Discharge FC 1024&FC1029 k Locks and latches FC1008& FC1029.2 'IS 59.1iNei C1 iF c 4'i 1 I ' Sign: Normal FC 1011 &FC1029 '�t Sign:backup FC 1011.5.3& FC1029.7.5 AISLES: �/ , Main Aisle Width FC 1024/1025&FC1029.11 / ra+ � 0 !L' Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.2 / TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 / Exterior FC 1006.3 Clearance to Electrical FC 605.3 v\/ Electric Wiring Enclosed/Labeled FC 605.3.1 / X Combustibles in Equipment Rooms FC315.2.3 / F.D.Signage- FC 510 �( No Smoking Signs FC 310.3 r Storage FC 315.2 / Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 / Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 / 18" / 24" X EVAC SIGNS IN Rooms FC 404.6(R1 &R2) / Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 / Exterior Storage FC 315.3 , Vacant Buildings FC 311 / REINSPECTION DUE APPROXIMATELY Emergency Disconnect FC 2203.2 / 21 DAYS Insp OK NC DATE: OK NC SYSTEMS: FC 901.6 Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual kil L )t Sprinkler FDC S-\i . _ Kitchen Suppression Semi Annual ,� Fuel Island Suppression Semi Annual Hood Cleaning 3-6 -Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection ® HAANEN EN -�' GINEERI lob No`- Sheet No. 1 of MAY 14 2014 I i Subject: fI crs-acs TOWN OF OUErI :' a-ts A o to { i lc' BUILDi1�� IBy HS Cr Date 05 to o I Ef Load �c 00 rovis [S r-wls AA ycr -a Poop hlsscs z IopsF Shca.#h4t - A ps P Muhonico-I Lkchic-411 91 bpsF TO b-4 Roar- Dcad LOQ4 1--psr eZ� RUUF Snout Lo,kd ; ( OCNYS 16o$r) 51avund svo0 LoKd �9 = 56 psF —* Hal ro of Snow J-Ad �P s 6. Co• Ct 1 Gahe� e C` : £xPesv•t Fath-r Frr �ea n dv kt r� - 93 s purl(aU� pat pox./d "a F I-0 C TgVL Igo V.3. 1) C -F�eym-j {yips b6,>j J z 1.0 ('C41rtG 16o K.3 . L) P / Cl. r [ (".tC1roY 0124 ESSI �(p1�13 Tobac 1604 Qf m 0--4 Ce Ct x 0 s 6- x 1.6x1.0 xl•ox 5e pif 35 fsr- 254 Bay Rd - Queensbury,NY 12804- Phone:518-793-7444- Fax: 518-793-7061 - Email: hih(Mhihllc.com ® HAANEN ENGINEERING Job No 16055 Sheet No. 2- of. Subject: RHA A scnr-iJ-et rtownholae Ca}4e N,'(� By HS Date o5 Izzi1l3 <now 16dA ! arajajt'o� S,lopccl POP ,Snow �a 4 A �'OaF sdopr: ; SS: t2 FOY unblu YNc l-ed 51 p Stirf-arts f1?�30' Fo^r vv�vcr lid -ro o P oY R i 20 I-OY v¢r4;AO. Cd 7eoP J GS o 0. g, Fw all. 04vy SUrPaceS Cs = 6, 4;`S (onsidvC'era ,10 CS a o ,rJ q3 S Sloped WOO Sn' -10`d pa = CS' bP 6. 915x35 34-1 psP Say 35 juF IP— irc- U-nIDoaunccd Snow Todd fl5cg _sSJ F��ure �'S� = 35psF c.3p , 6. 3x 3s = Io.s-psP 6. 13' by + 14 = aa. SpsF S = t•S ; �ti= aslk _ ti� 2r 12 .2. xzo.s 1 33. SP5P 8 'v ;t 2X rS = s� 33•SPsF I o 5 P� 3SosF _ _ s 254 Bay Rd - Queensbury,NY 12804- Phone:519-793-7444- Fax:518-793-7061- Email:hih@hihllc.com © HAANEN ENGINEERING sob No 16o SS Sheet No. 3 of Subject: RHA P11cr;cic rc 7awnbb,A(C 9) 6, P Neu P By HSS Date-. 51P-03 Laihd L.Qa.d CoItusa.H m AScf -4-o! WIhd Lid CeaculaliaY1 C rjfvr,pAiRecA f,edam:, . ,A F, - 6. 4. 1) Sirhpl&fed cesiy-n wind prersurd �s3o � � f�djushncmk- P�clu`Y Fer buiad�v� hei�jhh- b �xposurc. )Mead -"of ixlr.�1.♦" �, 30 - �' ,C,xposare laewe� r1 ^ I o kZt = TopopKphia KclvY Cep L4&ihed i>7 S,-olion 6. 5. N Ii� X x'MT3o-vA-un(c Fc�clos p-#/r Cetkvn 6.1 . I . o bs3a S'ir+spliPied c�eriy, witid pre ssti, M o* 1,) = 3o p6 05 9 1-ie-a•i-eavVaJ 9�rO_ssuti-es 11e�c1t't fkrsW+es. CPO) PrP) l} s 14. A pip CcR n - 13• pst= C ' I • I PsF 5. 6 P /39. 9 psP G.ah - 114 Psr• f= -Sr•ftPaF _4. 3Pse C, o 11• S psr- G a °'ti P.sP y.$ pst bs q'9 F's r- II } � r -3 . 1 psi ca s i- I Co0..s 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061- Email: hihrabhihllc.com ® HAANEN ENGINEERING lob No 16oS5 sheet No. A of Subject: 6HR ftc; ri 7ay.rrl6%n jE) fkgAe I1ill -O By a Date Oz I-Z ,1113 Wiy A 1 v ad r aAwlwlion Since �,ori�wb1 WW ?MS Li d W-Th'C'4 1,vrW prep ayes CA re, ,! ass Wvh 1-5PsP, (Ans rrva-� of� ) w i vti F7U Wre . 15 Ps F e eru{d aced. Hence. Tvf-J base ShUY A-4 c, It P-\CI P-Mnure rh f'rm,� • Reu,' • c1i�f;en 15psf- x �,cir�l�' x Le�fiYl �'*�rTdi(t�oY !-o FyD*1 —rtes �1ree.11a�1 ISpsP x Zop� X 161 P4 483 lei Ps 64J 50 kips -TA rj baSt SIn"Y d4a � �"'��I rresww— iv< 'side 4-u sicle direch'avl _ �PSF x he 11P idJ� Pf X 2 0 r,� X Ca 61 PA- Sad 15 kits 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax:518-793-7061- Email:hih(mhihllc.com ® HAANEN ENGINEERING Job No 6 o55- Sheet No. �` of Subject:_ RNA &sacia#Cs By HSC Date 061d,11 13 Seic,r,ic Aha.j�SiS LAsq =�- os) �Cy) Oe♦cxMine Seismic -toCLd C bcN4s of ASCE 7-os Sit. C.lassiFic-.4on _ 4,�knuwv hCncc.) si Ft "as's 1J SS = 'Mapped rnC6 S 9rrcC4 do+ p"J spccFrul -rupaonse acc.elr-* h'on Qwn^e-k r ak 5 hart/ periods 51 = IntpPed MCS 5 y�,re,�F �a�.,P�l ,J spech�l 2eSP°„Se acceler+.ko., PqrG M t I•C'Y �,} 1 3EG• 0. 039 y Fy S, 0. 159 sym Z 6.2�� Cpl z 21 Sr,, , a, 129 J2ismic I)esiyy) �ra o+`J occupancy C,.)etay 1- oa IL� FaY SOS S n G - g C�htG Ij' ii —1 Fzrr Sol : or 129 S do — 3 C?u61f- 11.6 -2, seismic besi5h (3 . 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061- Email: hih@hihllc.com ® HAANEN ENGINEERING Job No-----L6-OSI Sheet No. A of — Subject: RHA llywl� 1 ' Townhouses IFCo+J,do kiAl By lSN Date 0.5 024 �3 52ls M;r C,rene7M4 ReSponac spea I-^M `r = C� h„ wl+-ens Ct o , 2, h,� : 30 x T 74 T X SP = o, 25 x O 12 3 � 6. �I Sec. Sm Ti Soy 6. 1 Z !3 z O. ,44 sea. Sns c.23 � Us'IwJ P_qu' vG1c�-t ,lett .load pncedare 5�eisf3ate- shts,r V Cs. w Li P) Cs ' +} e- ,SSL'ISrn"C -rrspot,se ca -eFPici'e 41 VJ eFPec.Five 5edtin1c we(�*Kk CS Sns 6, 2�-g z o, 0 429 . p ,.o P- � G 3 rat Li51d f7Lnec1 WaAIS S�adFt� Wim Woo SJ�tpamelS ?u,}-tfcl fpy 3l ebv rtsi�l� c. 12. 2-- I� 254 Bay Rd - Queensbury, NY 12804- Phone:518-793-7444- Fax: 518-793-7061- Email: hih@hihlic.com ® HAANEN ENGINEERING Job NO--JI—OLS.- Sheet No. I of Subject: F P(4 Rus•r ia-t-e s Twat h o sus •t-{z�24 C H By S(r[ Date 5 a2q{ 1 JL��$lnlc Ic�� Cw�cula}i0YIf ( ) = Seismic Oead Aoo.J op S}y�tf�e RodF Oectd LackA , 14p5Fx 46P+ x 161 & fly FlooY kAe , kCjP} X ttl Pa- �aK + 201, OF Svnow UcA. _ 0 C.4 xi( IFk - y T�Iu) ,2Wr- To>•cJ Seigr,.,;C9.6Gk x lob bcue ,gheuY 0, 042- x 230k � < la kips G $e kips. Hence, W'tnC1 JULk ya 5 10-4erns Ihc desjejY), 254 Bay Rd - Queensbury,NY 12804- Phone: 518-793-7444- Fax: 518-793-7061- Email:hih(&hihllc.com COMcheck Software Version 3.9 Envelope Complianc dtli i�� e TOWN OF QUEENSBURY BUILDING & CODES 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title : New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Ddve Schennerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Spdngs,NY 12866 rich@schennerhomconstruction.com 518-580-1905 ephall@nycap.rr.00m Section 2: General Information Building Location(for weather data): Warren,New York Climate Zone: 6a Building Space Conditioning Type(s): Nonresidential Vertical Glazing/Wall Area Pct.: 12% Activity Type(s) Floor Area Multifamily 12330 Section 3: Requirements Checklist Envelope PASSES:Design better than code. Climate-Specific Requirements: Component Name/Description Gross Cavity Cont. Proposed Budget Area or R-Value R-Value U-Factor U-Factorial Perimeter Odentation:NORTH Exterior Wall 3:Wood-Framed, 16"o.c. 1070 21.0 0.0 0.062 0.051 Door 17: Insulated Metal,Swinging 18 - - 0.300 0.700 Door 18: Insulated Metal,Swinging 18 - - 0.300 0.700 Door 19:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 20:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 21:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 40 - - 0.290 0.350 Door,SHGC 0.65 Exterior Wall 4:Wood-Framed,16"o.c. 384 21.0 0.0 0.062 0.051 Orientation:EAST Exterior Wall 1:Wood-Framed, 16"o.c. 1560 21.0 0.0 0.062 0.051 Door 1:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 2:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 3:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 4:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 5:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 6:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 7:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 8:Insulated Metal,Swinging 20 - -- 0.300 0.700 Door 9: Insulated Metal,Swinging 20 - - 0.300 0.700 Door 10:Insulated Metal,Swinging 20 - - 0.300 0.700 Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 1 of 12 Door 11:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 12:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 13:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 14:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 15:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 16:Insulated Metal,Swinging 20 - - 0.300 0.700 Exterior Wall 2:Wood-Framed,16"o.c. 1248 21.0 0.0 0.062 0.051 Window 1:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 248 -- - 0.290 0.350 Orientation:SOUTH Exterior Wall 7:Wood-Framed,16"o.c. 1070 21.0 0.0 0.062 0.051 Door 28:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 29:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 30:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 31:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 32:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 40 - - 0.290 0.350 Door,SHGC 0.65 Exterior Wail 8:Wood-Framed, 16"o.c. 384 21.0 0.0 0.062 0.051 Orientation:WEST Exterior Wall 5:Wood-Framed, 16"o.c. 1560 21.0 0.0 0.062 0.051 Window 2:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 217 - - 0.290 0.350 Door 22:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 23:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 24:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 25:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 26:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 27:Insulated Metal,Swinging 20 - - 0.300 0.700 Exterior Wall 6:Wood-Framed, 16"o.c. 1248 21.0 0.0 0.062 0.051 Window 3:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 496 - - 0.290 0.350 Orientation:UNSPECIFIED ORIENTATION Roof 1:Attic Roof with Wood Joists 7014 38.0 0.0 0.027 0.027 Floor 1:Slab-On-Grade:Unheated,Vertical 4 R 529 - 10.0 - - (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: ❑ 1. All joints and penetrations are caulked,gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows,doors,and skylights certified as meeting leakage requirements. ❑ 3. Component R-values&U-factors labeled as certified. ❑ 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. Lj 5. 'Other components have supporting documentation for proposed U-Factors. El 6. Insulation installed according to manufacturers instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. 7. Stair,elevator shaft vents,and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. 8. Cargo doors and loading dock doors are weather sealed. ❑ 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283,are sealed with gasket or caulk. Lj 10.Building entrance doors have a vestibule equipped with self-dosing devices. Exceptions: LJ Building entrances with revolving doors. LJ Doors not intended to be used as a building entrance. Doors that open directly from a space less than 3000 sq.ft.in area. Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. E] Doors opening directly from a sleeping/dwelling unit. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed envelope system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 2 of 12 When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Cod Ethan P.Hall-Architect r /3 Name-Title Signature , , pgT Date JAW �70A0 Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill ApartmentsXRJT 8-plex\Cottage Hill.cck Page 3 of 12 COMcheck Software Version 3.9.2 Interior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Drive Schennerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schermerhomconstruction.com 518-580-1905 ephall@nycap.mcom Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Multifamily 12330 0.7 8631 Total Allowed Watts= 8631 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Multifamily(12330 sq.ft.) Compact Fluorescent 1:Spiral 23W:Electronic: 1 136 32 4352 Total Proposed Watts= 4352 Section 4: Requirements Checklist Interior Lighting PASSES:D- 0%better than code. Lighting Wattage: F-1 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 8631 4352 YES Controls,Switching, and Wiring: ❑ 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: LJ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. Fl 4. Independent controls for each space(switch/occupancy sensor). Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 4 of 12 Exceptions: ❑ Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. ❑ 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑ B. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires,dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps,switching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant-sensing device controls the area. ❑ The area is a corridor,storeroom,restroom,public lobby or sleeping unit. ❑ Areas that use less than 0.6 Wattslsq.ft. ❑ 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft Exceptions: ❑ Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security. ❑ 10.Photocelllastronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. ❑ 11.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts). Exceptions., ❑ Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checidist. /:� Ethan P. Hall-Architect M►' Q4k is MW Name-Title Cwature Date Project Title: New Townhouse Apartment Report date:01/02114 Data filename:Y:\Schernerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 5 of 12 COMcheck Software Version 3.9.2 Exterior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: New Townhouse Apartment Exterior Lighting Zone: 2(Residentially zoned area) Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Drive Schermerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schennerhomconstmction.com 518-580-1905 ephall@nyrap.rr.wm Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts /Unit (BxC) Main entry 8 it of door width 20 Yes 160 512 Total Tradable Watts'= 160 512 Total Allowed Watts= 160 Total Allowed Supplemental Watts"= 600 Wattage tradeoffs are only allowed between tradable areas/surfaces. A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Main entry(8 ft of door width):Tradable Wattage Compact Fluorescent 1:Spiral 23W:Electronic: 1 16 32 512 Total Tradable Proposed Watts= 512 Section 4: Requirements Checklist Lighting Wattage: ❑ 1. Within each non-tradable arealsurface,total proposed watts must be less than or equal to total allowed watts.Across all tradable areas/surfaces,total proposed watts must be less than or equal to total allowed watts. Compliance:Passes using supplemental allowance watts. Controls, Switching, and Wiring: ❑ 2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. ❑ 3. Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor(with time switch),or an astronomical time switch. ❑ 4. Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. F-1 5. All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 6 of 12 Exterior Lighting Efficacy: ❑ 6. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt. Exceptions: ❑ Lighting that has been claimed as exempt and is identified as such in Section 3 table above. ❑ Lighting that is specifically designated as required by a health or life safety statue,ordinance,or regulation. ❑ Emergency lighting that is automatically off during normal building operation. ❑ Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checidist. Ethan P. Hall-Architect r 1 Title /my Zp/L� Name- e Signature Date Project Title: New Townhouse Apartment Report date:01/02114 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 7 of 12 COMcheck Software Version 3.9.2 Mechanical Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Drive Schermerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schenmerhomconstruction.com 518-580-1905 ephall@nycap.rr.com Section 2: General Information Building Location(for weather data): Warren,New York Climate Zone: 6a Section 3: Mechanical Systems List Quant ftstem Type�ption 1 HVAC System 1 (Single Zone) Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 2(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kStu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 3(Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBW/h,Air-Cooled Condenser Fan System: None 1 HVAC System 4(Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-cooled Condenser Fan System: None 1 HVAC System 5(Single Zone) Heating: 1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 6(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 7(Single Zone): Project Title: New Townhouse Apartment Report date:01/02/14 Data filename: Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.ock Page 8 of 12 Heating:1 each-Central Furnace,Gas,Capacity=60 Muth Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 8(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtuth Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBhA,Air-Cooled Condenser Fan System: None 1 Water Heater 1: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 2: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 3: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 4: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 5: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 6: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 7: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 8: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF Section 4: Requirements Checklist Requirements Specific To: HVAC System t : LI 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) Cj 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 2 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) C] 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 3 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 4 : Lj 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 5 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 6 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) Ej 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 7 : Project Tills: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage HIII Apartments\RJT 8-plex\Cottage Hill.cck Page 9 of 12 ❑ 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 8 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) Lj 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: Water Heater 1 : ❑ 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btuth(if>12 kW)) 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. Lj 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To:Water Heater 2 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. Ll 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 3 : O 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To:Water Heater 4 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) Lj 2. First 8 ft of outlet piping is insulated ❑ 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 5 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'17 for non-dwelling units and 110'F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 6 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) ❑ 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To:Water Heater 7 : I] 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btuth(if>12 kW)) 2. First 8 ft of outlet piping is insulated C] 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. Lj 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To:Water Heater 8 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(If>12 kW)) 2. First 8 ft of outlet piping is insulated Cj 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110'F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Plant equipment and system capacity no greater than needed to meet loads Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:1Schennerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 10 of 12 Exception(s): ❑ Standby equipment automatically off when primary system is operating ❑ Multiple units controlled to sequence operation as a function of load ❑ 2. Minimum one temperature control device per system ❑ 3. Minimum one humidity control device per installed humidification/dehumidification system ❑ 4. Load calculations per ASHRAE/ACCA Standard 183. ❑ 5. Automatic Controls:Setback to 55°F(heat)and 85"17(cool);7-day clock,2-hour occupant override,10-hour backup Exception(s): ❑ Continuously operating zones ❑ 6. Outside-air source for ventilation;system capable of reducing OSA to required minimum ❑ 7. R-5 supply and return air dud insulation in unconditioned spaces R-8 supply and return air dud insulation outside the building R-8 insulation between duds and the building exterior when duds are part of a building assembly Exception(s): ❑ Ducts located within equipment ❑ Ducts with interior and exterior temperature difference not exceeding 15°F. ❑ 8. Mechanical fasteners and sealants used to conned duds and air distribution equipment ❑ 9. Ducts sealed-longitudinal seams on rigid duds;transverse seams on all ducts;UL 181A or 1018 tapes and mastics ❑ 10.Hot water pipe Insulation: 1.5 in.for pipes—1.5 in.and 2 in.for pipes>1.5 in. Chilled water/refigeranttbrine pipe insulation: 1.5 in.for pipes—1.5 in.and 1.5 in.for pipes>1.5 in. Steam pipe insulation: 1.5 in.for pipes<=1.5 in.and 3 in.for pipes >1.5 in. Exception(s): ❑ Piping within HVAC equipment. ❑ Fluid temperatures between 55 and 105°F. ❑ Fluid not heated or cooled with renewable energy. ❑ Piping within room fan-coil(with AHRI440 rating)and unit ventilators(with AHRI040 rating). ❑ Runouts<4 R In length. ❑ 11.0peretion and maintenance manual provided to building owner ❑ 12.Thermostatic controls have 5°F deadband Exception(s): ❑ Thermostats requiring manual changeover between heating and cooling ❑ Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. ❑ 13.8alancing devices provided in accordance with IMC(2006)603.17 ❑ 14.Demand control ventilation(DCV)present for high design occupancy areas(>40 person/1000 ft2 in spaces>500 112)and served by systems with any one of 1)an air-side economizer,2)automatic modulating control of the outdoor air damper,or 3)a design outdoor airflow greater than 3000 cfm. Exception(s): ❑ Systems with heat recovery. ❑ Multiple-zone systems without DDC of individual zones communicating with a central control panel. ❑ Systems with a design outdoor airflow less than 1200 dm. ❑ Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cirri. ❑ 15.Motorized,automatic shutoff dampers required on exhaust and outdoor air supply openings Exception(s): ❑ Gravity dampers acceptable in buildings<3 stories ❑ 16.Automafic controls for freeze protection systems present ❑ 17.Exhaust air heat recovery included for systems 5,000 cm or greater with more than 70%outside air fraction or specifically exempted Exception(s): ❑ Hazardous exhaust systems,commercial kitchen and clothes dryer exhaust systems that the Intemationai Mechanical Code prohibits the use of energy recovery systems. ❑ Systems serving spaces that are heated and not cooled to less than 60°F. ❑ Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Heating systems in climates with less than 3600 HDD. ❑ Coding systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. ❑ Systems requiring dehumidification that employ energy recovery in series with the cooling coil. ❑ Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or,a separate make up air supply meeting the following makeup air requirements: Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 0-plex\Cottage Hill.cck Page 11 of 12 a)at least 75 percent of exhaust Flow rate,b)heated to no more than 2°F below room setpoint temperature,c)cooled to no lower than WF above room setpoint temperature,d)no humidification added,e)no simultaneous heating and cooling. Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. '1 Ethan P. Hall-Architect Name-Title Sigh9rure Date •7 Section 6: Post Construction Compliance Statement HVAC record drawings of the actual installation,system capacities,calibration information,and performance data for each equipment provided to the owner. ❑ HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. O Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schernerhom\Cottage Hill Apartments\RJT S-plex\Cottage Hill.cck Page 12 of 12 RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue �JG Glens Falls NY 12801 Voice 518 741 0268 Fax 518 741 0274 Email ephall@nycap.rr.com Special Inspection Report To: John O'Brien -Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 15 April, 2016 Re: Schermerhorn Residential Properties —Cottage Hill Townhouse Apartments — 100 Gentry Lane At the above referenced project location this office performed periodic on site observations of the construction. All items appear to be installed in accordance with the construction drawings. If there are any questions please contact our office. Regards Ethan P. Hall—Archite ;F- ,. ell Hall Architectu ` � Q2�,N�' SCF 1\'��. ✓ar YiSchcnnerhorn\Cottage Hill AparunentsTapenvorVSpecial Inspection Letter-100 Gentry Lane- I Apr 2016.doc 1 boo 1 2�IS to�� GWNY Consulting, LLC APR 1 69 Hayden Point Loop Diamond Point, NY 12824 BUILDING&CODES 518 221-3240 04/13/2016 Mr.Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100A Gentry Lane, Queensbury, NY 12804 Report Number: 0413161 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including In and 2'Floor= 1,408 SF Volume of the apartment,including 1"and 2nd floor= 11,876 CF Based on above,the following test data was collected: Infiltration Rate of the apartment at 50 Pascal= 1,063 CFM ACH50,Actual Changes per Hour at 50 Pascal= 1.063X60/11,876=5.4<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfa—Lha'" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GWNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr. Rich Schermerhorn Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 1008 Gentry Lane, Queensbury, NY 12804 Report Number: 0413162 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 1"and 2nd floor= 1,408 SF Volume of the apartment, including I"and 20d floor= 11,876 CF Based on above,the following test data was collected: Infiltration Rate of the apartment at 50 Pascal= 1,215 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,215X60/11,876=6.1 <7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy-+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfaw Graf" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GWNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr. Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100C Gentry Lane, Queensbury, NY 12804 Report Number: 0413163 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 1"and 2"'floor= 1,408 SF Volume of the apartment,including I"and 2'Floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rale of the apartment at 50 Pascal= 1,263 CFM ACH50,Actual Changes per Hour at 50 Pascal= 1,263X60/11,876=6.4<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfo s Cr raj" Stan Grainy, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 �RAJNY ".-onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr.Rich Schetmerhom Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100D Gentry Lane, Queensbury, NY 12804 Report Number: 0413164 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including I"and 2'Floor= 1,408 SF Volume of the apartment, including I"and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,243 CFM ACH50,Actual Changes per Hour at 50 Pascal= 1,243X60/11,876=6.3 <7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Stow Grajr.y Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 RAJNY ((_'onsu1bng, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr.Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100E Gentry Lane, Queensbury, NY 12804 Report Number: 0413165 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 1"and 2'floor= 1,408 SF - Volume of the apartment,including 1"and 2'floor= 11,876 CF Based on above,the following test data was collected: Infiltration Rate of the apartment at 50 Pascal= 1,299 CFM - ACH50,Actual Changes per Flour at 50 Pascal= 1,299X60/11,876=6.6<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%.calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfaw Greg" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAINY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr.Rich Schermerhom Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 10OF Gentry Lane, Queensbury, NY 12804 Report Number: 0413166 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAINY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including I"and 2'floor= 1,408 SF - Volume of the apartment,including 1"and 2nd floor= 11,876 CF Based on above,the following test data was collected: Infiltration Rate of the apartment at 50 Pascal= 1,250 CFM ACH50,Actual Changes per Flour at 50 Pascal= 1,250X60/11,876=6.3 <7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfaw 6;va4" Stan Grainy, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GWNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr.Rich Schermerhom Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100G Gentry Lane, Queensbury, NY 12804 Report Number: 0413167 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 10 and 2"'Floor= 1,408 SF Volume of the apartment,including 151 and 2"^floor= 11,876 CF Based on above,the fallowing test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,224 CFM ACH50,Actual Changes per Hour at 50 Pascal= 1,224X60/11,876=6.2<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%.calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, S*Le,Ciro j" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 .�RAJNY onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 04/13/2016 Mr. Rich Schermerhorn Schennerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 100H Gentry Lane, Queensbury, NY 12804 Report Number: 0413168 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property,as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 04/13/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including I"and 2""floor= 1,408 SF - Volume of the apartment,including 1"and 2'Floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,189 CFM ACH50,Actual Changes per Hour at 50 Pascal= 1,189X60/11,876=6.0<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfa w 4ara4" Stan Grainy, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 d ee + I^rg, I��Qyy�p9+fil�� rnn��4rraa IIJJYJryVu"�i � �u � t Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000241-2015 Case Module: Permit Inspection Date: 04/15/2016 Inspection Status: Passed Inspector. Mike Palmer Inspection Type: Gas Fireplace/Stove Job Address: 100 GENTRY LN LN Parcel Number 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Applicant [Schermerhorn Properties] Contractor [Schermerhorn Properties] Granted Permission [Sch Cottage Hill,LLC] Primary Owner [Schermerhorn Properties] Checklist Item Passed Comments Building Inspection notes-Building Inspection Notes YES Combustion Air-Combustion Air YES Firestop(s)-Wall Penetration -Firestop(s-Wall Penetration YES Tank Placement(if LP)-Tank Placement(if LP) YES General Comments-General Comments YES Witness Operation-Witness Operation YES Vent Clearance to Combustibles-Vent Clearance to Combustibles YES Clearances to Combustibles(all sides) -Clearances to Combustibles YES (all sides) Gas Shut-off Valve-Gas Shut-off Valve YES Floor Protection-Floor Protection YES Mantel-height above fp opening-Mantel-height above fp opening YES CSST Bonding-CSST Bonding YES Firestop(s)-Vertical Chase -Firestop(s)-Vertical Chase YES N/A CO Detection-CO Detection YES Vent Chimney Termination -Vent Chimney Termination YES Hearth Extension(if any)-Hearth Extension(if any) YES N/A Denny Palmer,Mike(Inspector) Apr 15,2016 Page(19) , if TOWN OF QUEENSBURY FIRE MARSHAL g z D� � 742 Bay Road, Queensbury, NY. 12804-5902 /' � 761-8205 / 761-8206 Fax: 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the installation manual accompanying the appliance. No deviation from the manufacturer's instructions or specifications is allowed. Permit#: Name: Inspection Date: He—t S—t t Address: 4 d,, c��:►-+n /ate- Time: i Inspector: `"""1) Rough-in/ inal: Appliance Manufacturer: coQ cA-10ri. Model#: Z 1 Zc) 3 3 '+ M _Direct Vent _Factory Built Chimney _Flue Size Double Wall _Triple Wall _Insulated Yes No N/A Comments Floor Protection e Ok Clearances to Combustibles(all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearance to Combustibles C60.0 01,0 Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-off Valve Combustion Air Hearth Extension (if any) Mantel-height above f/p opening 24 I+S j Witness Operation Inc I C Tank Placement(if LP) CO Detection x 4I lc I l G CSST Bonding Lt)t g White-Building Department Yellow-Customer Pink-Fire Marshal Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 .-- Table 7:Horizontal vent termination clearances for buildings with combustible and noncumbustib/e exteriors Inside Corner Outside Corner Recessed Location See Table6 8 , Ni/ �j, o G r / �/ [Hi ®F — U /// lose. 0 Operable Fi%ed Balcony watt Side WWII Balcony wdh Perpendicular Side Wall Closed DOperable --i- Mmic7._ E1II1J a�li VI [V TERMINATION CAP O AIR SUPPLY INLET el GAS METER 0 RESTRICTED AREA (TERMINATION PROHIBITED) U.S.Installation** Canadian Installation* A Clearance above grade,veranda,porch,desk,or balcony 12"(300 mm)** 12"(300 mm)* B Clearance to window or door that may be opened 6"(150 mm) 6"(150 mm) for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW),and<50,000 Btu/h for fireplaces>10,000 Btu/h(3 kW) (15 kW), 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** C Clearance to permanently closed window 9"(229 mm) 12"(305 mm) recommended to prevent window condensation recommended to prevent window condensation D Vertical clearance to ventilated soffit located above the 18"(458 mm) 18"(458 mm) termination within a horizontal distance of 18"(458 mm) E Clearance to unventilated soffit 12"(305 mm) 12"(305 mm) 1 F Clearance to outside corner 5"(127 mm) 5"(127 mm) minimum minimum G Clearance to inside corner 6"(152 mm)minimum 6"(152 mm)minimum H Clearance to each inside of center line extended above 36"(910 mm) 36"(910 mm) meter/regulator assembly within a height of 15 ft above the meter/regulator assembly** within a height of 15 ft above the meter/ regulator assembly* I Clearance to service regulator vent outlet 36"(910 mm)** 36"(910 mm)* ' J Clearance to nonmechanical air supply inlet to building or 6"(150 mm) 6"(150 mm) the combustion air inlet to any other fireplace for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW)and<50,000 Btu/h(15 kW), for fireplaces>10,000 Btu/h(3 kW) 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** K Clearance to a mechanical air supply inlet 36"(910 mm)above if within 10 ft(3 m)horizontally** 72"(1830 mm)* L Clearance above paved sidewalk or paved diveway located 84"(2130 mm)$ 84"(2130 mm)$ on public property M Clearance under veranda,porch,deck or balcony , 12"(300 mm)*$ 12"(300 mm)*$ N Depth of alcove(maximum) 72"(1830 mm)** 72"(1830 mm)* 0 Clearance to termination(alcove) 6"(15.2 mm)** 6"(15.2 mm)* P Width of alcove(minimum) 36"(910 mm)** 36"(910 mm)* 0 Clearance to combustible above(alcove) 18"(457 mm)** 18"(457 mm)* ' In accordance with the current CSA-B149.1 National Gas And Propane Installation Code In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes $ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings *$ Only permitted if veranda,porch,deck,or balcony is fully-open on a minimum two sides beneath the floor 13 Innovative Hearth Products Installation Superior""DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8),with the following exception:The unit may not be recessed (allowance made for mantel legs/side trim in Figure 6). When the unit is installed with one side flush with a wall,the wall on the other side of the unit must not extend beyond the front edge of the unit(Figure 6). Table 8:Minimum Clearances * 1"(26mm)to wrapper for 45"model,all Back others 1/2"(13mm)to wrapper 0"(0 mm)to Spacers Sides 1/2"(13 mm)to wrapper 0"(0 mm)to Spacers** Top Standoffs 0"(0 mm)to top standoffs Floor 0"(0 mm) From Bottom of Unit to Ceiling 64"(1626 mm) Vent 3"(76 mm)—Top**** 1"(25.4 mm)—Sides and Bottom Front Service Clearance— 36"(914 mm) clearance immediately in front of viewing area(s) *3"(76 mm)above any horizontal/inclined vent component. **See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. ***Top vent clearance can be reduced to 2"on horizontal runs when first elbow is located at least 6 ft above the fireplace. The fireplace must be mounted on a fully supported base extending the full width and depth of the unit.The fireplace may be located on or near conventional construction materials. However, if installed on combustible materials,such as carpeting, vinyl tile or other combustible material other than wood flooring,the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Hearth Extension A hearth extension is not required with this fireplace. if a hearth extension is used, do not block the lower control compartment door.Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Shelf Height To provide for the lowest possible shelf surface, use the rear vent model. For top vent models,the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the fireplace. Do not insulate the space between the fireplace and the area above it(Table 9 and Table 10). The minimum height from the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Table 9and Table 10. Table 9::Combustible Shelf Height—Top Vent Top Vent with one 99°Elbow Model Secure Vent® Secure Flex®(flex elbow) DRC2033/DRT2033 44"(1118 mm) 46"(1168 mm) DRC2035/DRT2035 47"(1194 mm) 49"(1245 mm) DRC2040/DRT2040 52"(1321 mm) 54"(1372 mm) I ��'�l� , No combustibles Shelf Height or insulation DRC2045/DRT2045 50"(1270 mm) 52"(1321 mm) in the shaded (see tablle) area between the appliance and the shelf above it. immummummmi 14 Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 10:Combustible Shelf Height—Rear Vent Rear Vent with two 90°Elbows Model >_3"clearance from shelf to Secure Vent® Secure Flex®(flex elbow) top of fireplace and/or vent DRC2033/DRT2033 34"(864 mm) 34"(864 mm) pipe,whichever is higher DRC2035/DRT2035 35 1/2"(902 mm) 351/2' (902 mm) } �r _n DRC2040/DRT2040 40 1/2"(1029 mm) 401/2"(1029 mm) 1 i's�� No Shelf Height combustibles DRC2045/DRT2045 45 1/2"(1156 mm) 451/2"(1156 mm) (see table) or insulation in the shaded 7 area between the appliance and the shelf above it. Figure 6:Combustible Side Clearances Figure 7:Mantel Height At 6"minimum side wall clearance,a combustible / 1-.--Mantel depth wall can project Top View of 18(457) y Fireplace to any length. 16(406) -4— ,,m• , [ 46° Combustible materials 14(356) 3 1/2" allowed in shaded area -- (89 mm) "Safe Zone". 12(305) - ---- Combustible walls 10(254) shown in dark gray - -- 8(203) . - Combustible mantel --- - - -- legs may project beyond either side of 12 9 4 Hood - - the fireplace opening (305)10(203)6(102)2 as long as they are kept in. mm (254) (152) (51) - . within the shaded area ( ) �,- - - - - illustrated here. Fireplace 6" (152 mm) Wall Finishes/Surrounds/Mantels NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the fireplace front face(black sheet metal).Never allow combustible materials to be positioned in front of or overlapping the fireplace face(Figure 41). Non-combustible materials,such as surrounds and other fireplace trim,may be installed on the fireplace face,but they must not cover any portion of the removable glass panel or control compartment. Vertical installation clearances to combustible mantels vary according to the depth of the mantel(Figure 7). Mantels constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do not allow anything to hang below the fireplace hood. Minimum clearance requirements include any projections such as shelves,window sills, mantels,etc.above the fireplace. NOTE:To avoid heat-related finish damage,use finish materials rated 175°F,or higher,on the underside of the mantel. INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace, follow these steps: 1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction). 2. Remove the shipping pad, exposing the front glass door. 3. Remove the glass door(Page 57). NOTE: Place the glass door on the shipping carton to protect its surface. 15 TOWN OF QUEENSBURY FIRE MARSHAL 742 Bay Road, Queensbury, NY. 12804-5902 761-8205 / 761-8206 Fax: 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the installation manual accompanying the appliance. No deviation from the manufacturer's instructions or yoNb specifications is allowed. (� Permit#: ILI — IlCI) _ Name: �CHfix mi-ki, r' "'^tiff Inspection Date: t 15 )1' Address: 16C. Gctn2y L ,i w Time: 70— I or. ,/'f'''S'Q 1 Rou n Final: Appliance Manufacturer. SuPtnroyl, Model#: �.) IZT R033'fi'MIJ 1l Direct Vent Factory Built Chimney _Flue Size _Double Wall _Triple Wall —Insulated Yes No N/A Comments Floor Protection V/ Clearances to Combustibles(all sides) ✓ Firestop(s) Vertical Chase Wall Penetration ✓ Vent Clearance to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-off Valve Combustion Air Hearth Extension(if any) Mantel-height above f/p opening Witness Operation ✓ Tank Placement(if LP) CO Detection ✓ CSST Bonding White-Building Department Yellow-Customer Pink-Fire Marshal L . Town of Queensbury Building & Code Enforcement Office No. (518)761-8256 Q Framing / Firestopping Inspection Report Inspection request received: —4- 1 �4 " 1� Name: G t / F PD o Inspected on: 1 — Location: P)LV) 1- " 100 Arrive: k \ a.m. m. Permit No.: Inspector's Initials: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22"x 30°minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12°O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Yz(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side''/:inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing /Firestopping Inspection Report RUCINSKI HALL ARCHITECTURE �P�IV Ronald Richard Rucinski Ethan Peter Hall L� 627 Maple AvenueCIL Saratoga Springs NY 12866 Voice 518 580 1905 Fax 518 584 5012 Email ephall@nycap.rr.com Special Inspection Report To: Jahn O'Brien -Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 14 September, 2015 Re: Schermerhorn Residential Properties—Cottage Hill Townhouse Apartments— Building #9 At the above referenced project location this office performed on site observations of the shear wall installations prior to insulation. All items appear to be installed in accordance with the construction drawings. If there are any questions please contact our office. Regards, r � n psr� Ethan P. Hall —Architect Rucinski Hall Architecture r �7104N Y:\Scherrnerhom\Cottage I lilt ApartmentsTaperwork\Special Inspection Letter-Bldg 9- 14 Sept 2015.doc 1 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 7454437 Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's �7n instructions or specifications is allowed Permit#moi/ /v Schedule Inspection / ime`—vi7C/ /a/m' )pm anytime Inspecto�yc � Name V1=/7 Address ^ N Rough[ Final J y-itr - -� J Appliance Manufacturer j LOo'L., Model# V) - 03J 3-T7,11yl � Direct Ven Factory Built Chimney Flue Size_ Double Wall_ Triple Wall_ Insulated_ Yes No N/A Comments Floor Protection A�7� � J .. �� 37c Clearances to Combustibles (all sides) zwe Firestop(s) Vertical Chases,IV y_ �Dig Wall Penetration _ Vent Clearances to CombustiblesV1 1 en Chimney Termination Ciiihiney height must be 3 feet above roof penetration;2 feet above any combustible v '/ construction within 10 feet 9i9 zttsa A/r Gas Shut-Off Valve I ��� •UNIT G /��'�� �y7 off' Un,T D- ffiszzo Combustion AirT— �'Sh'2�z j V ��yFf2ZG Hearth Extension(if any) . ' _ ont) r— < — Mantel '61e /� ✓til G� Height above Vp opening raZ L(�� i�d� V nt'r Witness Operation �� �9�� Tank Placement(if LP) CO Detection /- U CSST Bonding 7A11 /V White—Building Dept. Vellum—Cust uner Pink—Fire Marshal �. Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re t re i Queensbury Building & Code Enforcement Arrive: Z` a / p : 1?��_a m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME:_ G 1 ����,� _ PE #: M-1� LOCATION: R� nC - 1nk� CSE 1,p,�,,-:-INSPECT ON: -7- 1y -\�5 TYPE OF STRUCTURE: Y N NIA Rough Plumbing / Nail Plates Plumbing Vent I Vents in Place 1 'Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Tyvelk or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15, 2005, revised January 7, 2008 I ..� Town of Queensbury Building&Code Enforcement Nb) Office No.(518)761-8256 2-1 Rough Plumbing 1 Insulation Inspection Report Inspection request received: 15 Name: t v Ime�✓t ,oy✓� Inspected on: lo Location: �Y4(1 100 (fv-vkn Arrive: a.m. p.m J Permit No.: I-A-1 Inspector's Initials: Type of Structure: COMMENTS Y N NA Plumbing under slab Rough Plumbing/Nail Plates Plumbing Vent I Vents in Place 1 '/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Drain I Vent Air I Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air I Head 50 P.S.Ifor 15 minutes Insulation I Residential Check I Commercial Check /jo va�QoA� Window Sealing vt►�C� Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape Blower Door Test Air Sealing Rough Plumbing I Insulation Inspection Report Town of Queensbury Building&Code Enforcement Office No.(518)761-8256 �oo1J Rough Plumbing I Insulation Inspection Report Inspection request received: (0 t Za15 Name: 50-,krvy"u ✓1N.0I/C\ Inspected on: Location: )DIN QLO n . o Arrive: a . 1 P.M. Permit No.: la^\It _ Inspector's Initials: Type of Structure: `Kl"nVQk,4- -& COMMENTS Y N NA Plumbing under slab Rough Plumbing/Nail Plates 1 Plumbing Vent I Vents in Place 1 '/z inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain I Vent Air I Head 5 P.S.I.or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air I Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door I Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed property/No duct tape Blower Door Test Air Sealing Rough Plumbing I Insulation Inspection Report Town of Queensbury Building&Code Enforcement �! Office No.(518)761-8256 Rough Plumbing / Insulation Inspection Report Inspection request received: 1 Name: M ,( I, ( Inspected on: S Location: �b�G��-y Lr\J, Arrive: p.m. Permit No.: Inspector's Initials: n� Type of Structure: G ' COMMENTS Y N NA Plumbing under slab Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 '/z inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft.above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes 6insulation/Residential Check I tornmercial Che a zLo Window Sealing Tyvek or Similar Exterior Sealant s CAa Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape U, J RW FAL Blower Door Test Air Sealing bCiL� Rough Plumbing/Insulation Inspection Report Town of Queensbury Building & Code Enforcement -F� Office No. (518) 761-8256 115 Framing I Firestopping Inspection Report Inspection request received: rDt 115 Name: suA Inspected on: SI15`Za+S Location: CAltuelp, 4WD `J . Arrive: L) M. M. Permit No.: (� ^1 O Inspector's Initials: TYPE OF STRUCTURE: Y N NIA COMMENTS: dC Framing (" Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing 1 Bridging ✓� Joist hangers Jack Posts/Main Beams y1 Exterior sheefing nailed property Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom-6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y:inch or 518 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) ✓/ 20 in.(W) ✓� 5.7 sf above/below grade / 5.0 sf grade ✓ Design Professional Sign-off,if required T � ED ETt��� NALL� IF F. Framing I Firestopping Inspection Report Town of Queensbury Building&Code Enforcement -.-� o Office No. (518)761-8256 Rough Plumbing / Insulation Inspection Report Inspection request received: L (p / Name: Inspected on: Location: 1 (2U Arrive: a.m.l p.m. Permit No.: u— 1 -70 IT�1�1�( ct Inspector's Initials: Type of Structure: COMMENTS Y N NA Plumbing under slab ough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 '/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I.or 10 ft.above highest connection for 15 minutes Pressure Test / Water Supply Piping V/ Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/Insulation Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection req st re e . Queensbury Building & Code Enforcement Arrive: ZZ C-� am 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: r� NAME: 1�rb,o l � PERMIT LOCATION: 117n � INSPECT ON: 0 TYPE OF STRUCTURE: f3 9 Y N N/A Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing D Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing insulation Inspection-02 05 13 Town of Queensbury Building & Code Enforcement Dn Office No. (518)761-8256 Framing 1 Firestopping Inspection Report Inspection request received: Name: C n+, Inspected on: 5 1 Location: /S-D (4nen&{r Arrive: 77 Permit No.: /`-1—I'2D Inspector's Initials: TYPE OF STRUCTURE: /DTD 4con r to per& 'v Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-of,if required Framing I Firestopping Inspection Report Foundation Inspection Report Office No.(518)761-8256 Date Ins coon reque d Queensbury Building&Code Enforcement Arrive. `o Depart:' <� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ` NAME: �CJLO31 Ok P IT#: �rJD LOCATION: IZID INSPECTON: l TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump 7Fo ting Drain Stone: 2 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab P C/Cast/Copper Foundation Insulatio K tenor erior R - Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM -fhu.rs 9-// Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins ection req r iv Queensbury Building & Code Enforcement Arrive: % Zu 742 Bay Road, Queensbury, NY 12804 Inspector's Initial . NAME: 301 00-rM at'VQ)y n PERMI LOCATION: /rro U`co�rL INSPECT ON: — •—/'y' TYPE OF STRUCTURE: F, Ido Y N/A IRough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent / Ia ✓/ '� S or 10 ft. above highest connection for 15 minutes ressure Test a wevvva- Waterer Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation /Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing—insulation Inspection-02 0513 Foundation Inspection Report 0 // Office No.(518)761-8256 Date Instion reques ece' Queensbury Building&Code Enforcement Arrive: cel�am/ epart: m 742 Bay Rd,Queensbury,NY 12804 Inspector's Initials: �7 NAME: S(h C�,v� C/`VgLA) — CU\04N + T LOCATION: c. 4j..4W L—N INSPECT ON: TYPE OF STRUCTURE: Comments 2 Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab :13ackfill Approval Plumbing Under Slab 2� PVC/Cast/Copper Foundation Insulatic Interior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspecdon Forms\Foundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM C (USS_ Foundation Inspection Report //^ Office No.(518)761-8256 Date InsZection r e : U /I I L/ Queensbury Building&Code Enforcement Arrive: D Depart: 742 Bay Rd.,Queensbury,NY 12804 Inspectoniti NAME: lk C,/;v�(--A� (u!Z A 0 '1 1 /PERMIT#: LOCATION: UC) t A js� INSPECT ON: L TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. 7 ` oundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&CodesUnspecbon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM C � IQm� Foundation Inspection Report Office No. (518) 761-8256 Date InspectionFscQueensbury Building&Code Enforcement Arrive: - Depart: :1 a742 Bay Rd.,Queensbury,NY 12804 Inspector's ImNAME: �GJf—m e I' rn LOCATION: INSPECT ON: C9 ICJ ' 7 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement 1/ of the concrete. ^V L Vk' ,N—� Materials for this purpose on site. �Ep7I ` � MoMhtion/Wallpour , Q T D Reinforcement in Place L lv Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofingl' Z,\. Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re uesZceQueensbury Building&Code Enforcement Arrive: epart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: S 0,k-Ah 4,, 4f-% yrs .i., e RMIT#: `� LOCATION: INSPECT ON: 1 a —Cn d l 7 TYPE OF STRUCTURE: S Comments Y N N/A Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM BUILDING & CODES ^ cUv RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski 14 2014 Ethan Peter Hall 627 Maple Avenue TOWN OF OUEENSBUR Saratoga Springs NY 12866 BUILDING & CODES Voice 518 580 1905 Fax 518 584 5012 Email ephall@nycap.rr.com Special Inspection Report To: David Hatin -Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 13 May, 2014 Re: Schermerhorn Residential Properties—Cottage Hill Townhouse Apartments —8 Unit Building #8 & #9 At the above referenced project location this office will be performing special inspections of the project in accordance with the requirements of the New York State Building Code. Letters of our field observations will be provided as required for each of the new buildings. Contracts between the concrete testing agency and the contractor will be provided by the developer. If there are any questions please contact our office. Regards, Ethan P. Hall —Architect Rucinski Hall Architecture YASchermerhom\Cottage Hill Apartments\R!T 8-plex\Special Inspection Letter 13 May 2014.doc 1 RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall 627 Maple Avenue Saratoga Springs NY 12866 Voice 518 580 1905 a Fax 518 584 5012 G> Email ephall@nycap.rr.com Q r� Transmittal l Mar 13 2014 D To: Dave Hatin —Town of Queensbury— Code Enforce men�COffi�r kD F LIE'wg G& Cp EERY From: Ethan Hall Date: 13 May, 2014 Re: Schermerhorn Cottage Hill —8 unit Townhouse apartment building #9 Attached are two (2) copies of the site plans form the 8 unit Townhouse apartment building permit application. Also attached is the contract between Schermerhorn Construction and Grajny Consulting LLC for the blower door test for the units. I believe this is all the information that is outstanding on the application for the building permit, if there are any additional items required please contact our office to discuss. YASchermerhom\Collage Hill ApartmentsTapemorUmsmittal 6 Jan 2014.doc 1 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manhelm,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL - 4k �s Permit No.CC..............2a.........Cert. N'— 42994 Cut-i,Card No..................................... Owner...... Location .*....146.. . ...... ...................... . ................ ......... InstallatlCo ... .......op rllsisti4...P-1--w... . ........ /ezras ............................/....... ................. ..... .................&.................. ......... . .... ........... ......................................................... ..................................P......................e....z.......f...c..... ......................................................................................................... Installed By.............. .. 4 ...................................... Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege f maki'7-,J'%saetcte.i*ons at any time, and if its rules are violated,the Company shall have the right to v e thi INSPECTOR... ...—� Date............................................ I