Loading...
SOLAR-000035-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 at Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000035-2017 Date Issued: Friday, July 14, 2017 This is to certify that work requested to be done as shown by Permit Number SOLAR-000035-2017 has been completed. Tax Map Number: 297.17-1-51 Location: 375 RIDGE RD Owner: Martha McGee Applicant: Solar City This structure may be occupied as a: Solar Panel System 126 s.f. No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, �Jw� Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000035-2017 Tax Map No: 297.17-1-51 Permission is hereby granted to: Solar City For property located at: 375 RIDGE RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Martha McGee Solar Panel-Residential $2,411.00 Owner Address: 31 Miller Ridge Way Total Value $2,411.00 Hartford,NY 12838 Contractor or Builder's Name/Address Electrical Inspection Agency Solar City PO Box 670 Amsterdam,NY 12010 Plans&Specifications Solar Panel System 126 s.f. No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,February 22,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Quecnsbug before the exxy�/'ationdate.) Dated at the Town of(: nsb •- (/ ke e d February 22,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement ACCESSORY STRUCTURE APPLICATIONOffice Use Only Received - DATE Tax Map ID TAX MAP ID 297.17 - 1 - 51 Permit No. LIAR.-0.N5- 201' ZONING Permit Fee 14'vo, kywZA"Q \443 Rao Fee HISTORIC SITE —Yes No Approvals SUBDIVISION NAME Lot# APPLICANT Loreen Harvey OWNER Martha McGee ADDRESS P.O. Box 670 ADDRESS 375 Ridge Road Amsterdam, NY 12010 Queensbury, NY 12804 PHONE 518 - 332 - 0671 PHONE 5186325790 CONTRACTOR Solar City COST OF CONSTRUCTION(ESTIMATED): $ 2,411.00 ADDRESS: P.O. BOX 670 BUILDINGADDREss: 375 Ridge Road Amsterdam, NY 12010 Queensbury, NY 12804 PHONE: 518 - 332 - 0671 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE Loreen Harvey PHONE 518-332-0671 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 2n0 floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck Detached Garage(#of cars Dock Pole Bam Porch-open 2017 "Porch–3 season, Covered, Enclosed TO Shed L BUILDI & RY Other Accessory Structure(s) 125.79 Sq ft "Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that [/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: Loreen Harvey Date: 2 - 6 - 17 Signature: Date: 2 - 6 - 17 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES 297. 17.1.51 SOLAR-000035-2017 A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A McGee, Martha AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. 375 Ridge Road BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING Solar Panel Sys. (no upgrade) 126 s.f. DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING � EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, L LCOPY FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE FE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY LB Q 7 2017 HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. TOWN OF QUEENSBURY I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL } ca;� 'Y BUILDING DEPARTMENT f�OFJ Based on our limited examination,compliance Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). NG c� u u __ with our comments shall not be construed as Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER indicating the plans and specifications are in kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR full compliance with the Building Codes of kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC New York State. LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE --OV�ox4t � ( �� PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. BUILDING & 0'sp PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE RGVIeVUeC , SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL Dated STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY J V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT i 3R NEMA 3R, RAINTIGHT PV1 PV2 COVER SHEET SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES v Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2015 ^ IBC/IRC per 2016 NYS UNIFORM CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE MODULE GROUNDING METHOD: ZEP SOLAR 4. ALL WORK SHALL COMPLY WITH THE 2015 AHJ: Queensbury Town, Warren County INTERNATIONAL FIRE CODE ., _ REV BY DATE COMMENTS �. REV NAME DATE COMMENTS C * s UTILITY: National Grid (Niagara Mohawk) JB-1 281732 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �e®®`� � � CONTAINED SHALL NOT BE USED FOR THE MARTHA MCGEE Martha McGee RESIDENCE Efe Celikbilek ° ty. NORSHALL IT T OF BENDISCLOOSSED IN WHOLE ORT SOLARCITY CIN MOUNTING SYSTEM: 375 RIDGE RD 1.96 KW PV ARRAY ®��" PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 wFlashing—Insert ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: QUEENSBURY, NY 12804 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (7) HANWHA Q—Cells # Q.Plus—G4.1/SC-280 PAGE NAME SHEET: REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN [INVERTER: T.(650)638-1028 F.(650)638-1029 PERMISSION OF SOLARCITY INC. Delta # Solivia 3.8 TL COVER SHEET PV 1 1/30/2017 (668)-SOL-CITY(765-2469)www.solarcity.com PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH: 148 ARRAY AZIMUTH: 148 MATERIAL: Comp Shingle STORY: 1 Story G)- r I I� I L"D IJ / AC STRUCTU / CHANGE Q T i / I AL LEGEND lull? AL (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS L © AC DISCONNECT & WARNING LABELS CH se 0 DC JUNCTION/COMBINER BOX & LABELS S� D 6 �Q1P B DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS TRUCTURE CHANGE O DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN � A O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR A CONDUIT RUN ON INTERIOR (E)DRIVEWAY GATE/FENCE O HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED -bib SITE PLAN N Scale: 3/32" = 1' wE 01' 10' 21' va WNW/10/00010" S CONFIDENTIAL— THE INFORMATION HEREIN ADB NUMBER: J B-1281732 00 PREMISE OBNER: DESCRIPTION: DESIGN: ■ CONTAINED SHALL NOT BE USED FOR THE MARTHA MCGEE Martha McGee RESIDENCE Efe Celikbilek / BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �., l. ® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 375 RIDGE RD 1.96 KW PV ARRAY „SOIa�.C'}" PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES: QUEENSBURY NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (7) HANWHA Q—Cells # Q.Plus—G4.1/SC-280 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' T:(650) 638-1028 R(650)638-1029 Delta salivia 3.8 TL SITE PLAN PV 2 1/30/2017 (888)—SOL—CITY(765-2489)www.solaralty.com S1 SI (E) KNEEAWALL „ „ —11" 11'-2" 11 —816'-11 —5'—6 —11 " � (E) LBW (E) LBW (E) LBW A SIDE VIEW OF MP1A NTS SIDE VIEW OF MP16 NTS B MP1A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 1 23" 39" 0" STAGGERED MP113 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 32" 15" 65" 0" LANDSCAPE 64" 23" 39" 0" STAGGERED RAFTER 2X8 @ 16" OC ROOF AZI 148 PITCH 20 STORIES: 1 PORTRAIT 32" 15" 65" 0" ARRAY AZI 148 PITCH 20 RAFTER 2x8 @ 16" OC ROOF AZI 148 PITCH 20 STORIES: 1 C.J. 2X6 @16" OC Comp Shingle-Solid Sheathing ARRAY AZI 148 PITCH 20 X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. C.J. 2X6 @16" OC Comp Shingle-Solid Sheathing X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16"x1.5" BOLT WITH Sl 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT " HOLE. --------- --- --------- ZEP ---ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO OUNTINGCK AND ATTACH 16'-11" ZEP FLASHING INSERT (3) (2) MO RAFTERBU�NG LAG SCREW. (E) LBW (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING SIDE VIEW OF MP1C NTS (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE C 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES MP1C X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES [4)INSTALL LEVELING FOOT ON TOP LANDSCAPE 64" 23" 39" 0" STAGGERED (2-1/2" EMBED, MIN) OF MOUNTING BLOCK & PORTRAIT 32" 15" 65" 0" (E) RAFTER SECURELY FASTEN WITH BOLT. RAFTER 2X8 @ 16" OC ROOF AZI 148 PITCH 20 STORIES: 1 STANDOFF ARRAY AZI 148 PITCH 20 C.J. 2X6 @16" OC Comp Shingle-Solid Sheathing rX AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. J B-12 817 3 2 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: \\®1\ h� �� CONTAINED SHALL NOT BE USED FOR THE MARTHA MCGEE Martha McGee RESIDENCE Efe Celikbilek ®_ ; BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: o, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 375 RIDGE RD 1.96 KW PV ARRAY y. PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES QUEENSBURY NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleaNew Way THE SALE AND USE OF THE RESPECTIVE (7) HANWHA Q—Cells # Q.Plus—G4.1/SC-280 PAGE NAME SHEET REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Delta # SOlivia 3.8 TL STRUCTURAL VIEWS PV 3 1/30/2017 (888)-SOL-CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS t„5oiarc.ity,. ry -3y51eM JLruc1Urd1 Design Software Mountincii Plane Information Roofing Material Comp Roof Roof Slope 200 Rafter Spacing 16”O.C. Framing Type/Direction Y-Y Rafters PV System Type SolarQty SleekMounfl Zep System Type ZS Comp Standoff Attachment Hardware Comp Mount SRV Spanning Vents No Wind and Snow Desiccin Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Ultimate Wind Speed V-Ult 115 mph Fig.1609A Exposure Category C Section 26.7 Ground Snow Load pg 50.0 psf ASCE Table 7-1 Surrounding Roof Snow 35.0 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 35.0 psf ASCE Eq: 7.4-1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 24.4 psf Wind Pressure Ext.Pressure Coefficient U GC U -0.88 Fg.30.4-2A-tB/C-SA/8 Ext.Pressure Coefficient Down GC Down 0.45 Fig.30.4-2A/BIC-5A18 Design Wind Pressure P p=qh(GCp) Equation 30.4-1 Wind Pressure Up pcup) -21.4 psf Wind Pressure Down down 146.0 PSf ALLOWABLE STANDOFF SPACINGS X-Direction V-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 23" NA Standoff Confi uration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -193 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand/Capacity DCR 35.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 32" 65" Max Allowable Cantilever Portrait 15" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 14 5f PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -161 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand/Capacity DCR 29.4% CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: JB-1 281732 0 0 PREMISE OPMER: DESCRIPTION: DESIGN: CONTAINEDDAL ®®Dp4�O������SHALL NOT BE USED FOR THE MARTHA MCGEE Martha McGee RESIDENCE Efe Celikbilek a. , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 375 RIDGE RD 1.96 KW PV ARRAY O'�,. y. PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Georview Way THE SALE AND USE OF THE RESPECTIVE (7) HANWHA Q—Cells # Q.Plus-134.1/SC-280 PAGE NAME SHEET: REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Delta # SOlivia 3.8 TL UPLIFT CALCULATIONS PV 4 1/30/2017 (888)-SOL-CITY(765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:G404OB1200 Inv 1: DC Ungrounded INV 1—(1)Delta # Solivia 3.8 TL LABEL: A —(7)HANWHA Q—CellsQ.Plus—G4.1/SC-280 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:27017413 Inverter;380OW, 240V, 97.57., Zigbee, PLC PV Module; 2801, 256.4 PTC, 40MM, Blk Frm, MC4, 1000V, Zep Overhead Service Entrance INV 2 Voc: 38.97 Vpmax: 31.67 INV 3 Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER 20OA/2P Disconnect 3 Delta Solivia 3.8 TL (E) LOADS g z�ov Delta L1 � L2 20A/2� N 2 EA� 1 P ---- GND ———————————————————— _ EGCI Dc. DC, A ----------------- GEC ---TN DG Dc- MP 1: 1x7 EGC ——————————— — EGC————————————— — ---� I I I N 1 I 1 EGC IGEC _ D --- —G Z Z C.9 GEC TO 120/240V SINGLE PHASE UTILITY SERVICE i i i EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS #Q220 PV BACKFEED BREAKER B (1)CUTLER—HAMMER #DG221UR6 A (1)Delta #Solivia D� Breaker, 20A/2P, 2 Spaces Disconnect; 30A, 24OVac,Non—Fusible, NEMA 3R AC Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 —(1)Gro id Rod —(I)CUTLER— AMMER.#DG03ONB 5r8 x 8, Copper Ground�Neutral Kcit; 30A, General Duty(DG) R�T'(I)AWG#10, THWN-2, Black (2)AWG 110, PV Wire, 60OV, Black Voc 314.72 VDC Isc —9.41 ADC (2)AWG #10, PV Wire, 6OOV, Black Voc* =314.72 VDC Isc=9.41 ADC OIse(1)AWG#10, 1HWN-2, Red O (1)AWG #6, Solid Bare Copper EGC Vmp =221.69 VDC Imp=8.84 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =221.69 VDC Imp=8.84 ADC Lrt (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.8 AAC (1)Conduit Kit; 3/4' EMT . .. (1)Conduit Kit;.3/4`.EMT. .. ..... ... .... . ...... .... .. .... ...... ...... ......... -(1)AWG#8,.iHWN72,,Green ,. EGC/GEC, (1)Conduit,Kit;.3/4'.EMT ,, ,, ,,., , JB-1281732 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE MARTHA MCGEE Martha McGee RESIDENCE Efe Celikbilek �;,;So�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: IWO NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 375 RIDGE RD 1.96 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: QUEENSBURY NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (7) HANWHA Q—Cells # Q.Plus—G4.1/SC-280 SHEET. REV: DAIS San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME T:(650)63B-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: Solivia 3.8 TL THREE LINE DIAGRAM PV 5 1/30/2017 (888)—SOL—CITY(765-2489)www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: ,Label • _ • LabelLocation:. : =Code: • WARNING •_ • WARNING Per 690.31.G.3 _ ELECTRIC SHOCK HAZARD • ELECTRIC SHOCK HAZARD • DO NOT TOUCH TERMINALS NEC ' / THE DC CONDUCTORS OF THIS 690.35(F) Label •n: TO BE USED WHEN LOAD SIDES MAY BE ENERGIZED UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC DC DIN THE OPEN POSITION MAY BE ENERGIZED DISCONNECT UNGROUNDED NEC .•1 Label Location: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPIDCode: MAXIMUM POWER-_ •_ Code: SHUTDOWN 690.56(C) POINT CURRENT(Imp) A MAXIMUM POWER-_VNEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM VOLTAGE(Voc)_V SHORT-CIRCUIT_ CURRENT(Isc) A Label • • WARNING '• Per ..- INVERTER OUTPUT CONNECTION 690.64.13.7 Label • - • DO NOT RELOCATE WARNINGPer ••- THIS OVERCURRENT DEVICE ELECTRIC SHOCK HAZARD -� IF A GROUND FAULT IS INDICATED 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZEDLabel L• - • CAUTION '• Per ..- PHOTOVOLTAIC SYSTEM �, CIRCUIT IS BACKFEDNEC 690.64.B.4 „ Label • • Per WARNING ..- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALSNEC 690.17(4) - • • LOAD SIDES MAY BE ENERGIZ o CAUTION IN THE OPEN POSITION DUAL POWER SOURCEPer Code: DC VOLTAGE IS SECOND SOURCE IS 690.64.13.4 ALWAYS PRESENT WHEN PHOTOVOLTAIC SYSTEM SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • PHOTOVOLTAIC POINT OF Label • - • INTERCONNECTION Per PHOTOVOLTAIC AC PO ''1 � 690.54 WARNING: ELECTRIC SHOCK Code: _ HAZARD.DO NOT TOUCHNEC ' Conduit• • • DISCONNECT nnect •' TERMINALS.TERMINALS ON NEC 690.14.C.2 BOTH THE LINE AND LOAD SIDE Combiner '' MAY BE ENERGIZED IN THE OPEN (D): Distribution (DC): DC Disconnect POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND h�AIN BREAKER. InteriorConduit Label • - • (INV): Inverter With Integrated_ Disconnect MAXIMUM AC ' MAXIMUM AC A OPERATING CURRENT __ A OPERATING CURRENT Load -• Per Code: (M): UtiliMeter MAXIMUM AC .1 , MAXIMUM AC V , OPERATING VOLTAGE _ V OPERATING VOLTAGE • of • • � is •• . � � • i •• � 'INN I • • r •- Model RSS-600 4-2 Connection Diagram: I 4 DELTA RAPID SHUTDOWN BOX I ON ROOF WITHIN 10'OF PV I ® I I W I I , �oM1tvnr° C US I I a Its • • ..__ � n- 1 RSS �J a AC AC -- V Dc w. •- - DCPv- One conduit BREAKER GRID o Ac forallwiring t Technical Specifications 5V SIGNAL :. Input Ratings 600V DC 600V DC ouTPUT Max.Number of Input Circuit 1 4 / RAPID SHUTDOWN ®miaRated input Current Per String 20A 10A N/A 15A r' Output Ratings Max.Number of Output Circuit 1 2 Rated Output Current Per Circuit 20A 20A Maximum Current Controlled Conductor 25A 25A Output Terminal Wire Size 10AWG 12-6 AWG Output ConduitN/A 3/4"(two holes) ® ControlMethod PLC Signal 5V Signal Wire -� N/A 600V NIA 24-14 AWG �q / General Data Rapid S h utd ® n ®eV I c / • 7.87 x 5.91 x 2.09(200 x 150 x 53) 12.44x10.04x2.160kg) 55x55) �./ !llrsslll p�`,p Q � avymn.aim 2.861bs(1.3kg) 6.61bs(3.Okg) for Delta 3 ■ O"'7 0 6 TL Inverters! V rte rS input Connectors MC-4 PV Connector orAmphenol H4 PV Connector MC-4 PV Connector orAmphenol H4 PV Connector • MC4 PV Connector orAmphenol H4 PV Connector Screw Terminal Blocks Operating -40-158"F(40-70"C) -40-158•F(40-70"C) Delta's Rapid Shutdown Devices provide an automatic disconnect of 60OVDC ,•. -40-185-F(40-85°C) 40-185-F(40-85°C) residential or small commericial PV array system,fully compliant with the Rapid 0-100% 0-100% Shutdown requirements of NEC 2014 article 690.12. It is compatible with Delta's Operating ,- 2000m above sea level 2000m above sea level single-phase residential inverters. IT. . 10 Years 10 Years KEY FEATURES Standard Compliance • •- • NEMA4X NEMA 4X •NEMA 4X Protection UL 1741,CSA 222107-1 UL 1741,CSA 22.2 107-1 •Compact and Lightweight .. NEC 2014 Article 690.12 NEC 2014 Article 690.12 •Rack Mount Installation Delta Products Corporation,Inc. •Fast Connect with PV Connectors 46101 Fremont Blvd. •Compliant with NEC 2014 article 690.12 Fremont, CA 94538 Sales Email: Inverter.Sales@delta-corp.com •PLC Communication(Model RSS-600 1-1 only) Support Email: Inverter.Support@delta-corp.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 ® Support Hotline: +1-877-442-4832 Support(Intl.): +1-626-369-8019 C US Monday to Friday from lam to Spm PST(apart from Holidays) A &ELTA ,A ww.delta-americas.com www.delta-americas.com/solarinverters .:.W21A7 ­0_P..:.,..i: 'uhl-I....f,i.c Delta Solar Inverters Datasheet for SolarCity n j I-74-70 nv.4H --. 1 rtf : t; -1L a iC e l l__ `3- INPUT(DC) 600 V 380 V 95-SMV 200-500 V 18.0 A 20.0 A 20.0 A Per MPP tracker SolarClty - 25.0 A per MPP tracker / _ ``•� �) 4200 W 5000 W 5600 W 1.5 `'.�' Internal SOW(ity lC:; 1 2 2 4 OUTPUT(AC) i 3000 W 3800 W 5200 W 6600 W 7600 W 3000 W @ 208 V/ 3300 W @ 208 V/ 5200 W @ 208 V/ 6600 W @ 208 V/ 6600 W @ 208 V/ ! 3000 W @ 240 V 3800 W @ 240 V 5200 W @ 240 V 6600 W @ 240 V 7600 W @ 240 V 183-228 V @ 208 V/211-264 V @ 240 V i 14AA@208V/ 15.8A@208V/ 24.OA@208V/ 31.7A@208V/ 31.7A@208V/ 12.5A@240V 15.8A@240V 21.6A@240V 27.5A@240V 31.7A@240V ° 60 Hz 59.3-60.5 Hz 57.0-63.0 Hz <11.5w c3% >0.99 0.851-o.B5c <50 db(A)@ Im 1 • • - GENERAL SPECIFICATION 98% 97.5%@ 208V 197.5%@ 240V - I -13-156°F(-25-70°C)I derating above 122oF(506C) 40-18WF(-40-85-C) - - 0-100% 20DOm above sea level MECHANICAL DESIGN 19.5 x 15.8 x 8.5 in(495 x 401 x 216 mm) 26.8 x 15.8 x 8.5 in(690 x 401 x 216 mm) 43.0 lbs(19.5 kg) 65.0 Ibs(29.5 kg) Natural Convection Spring terminals in connection box . AWG 12-AWG 6Copper(According to NEC 310.15) 2 pairs of spring terminals in connection box 4 pairs of spring terminals in connection box AWG 12-AWG 6 Copper(Acowdirg to NEC 690.8) 2gBee 3 LEDs,44ine LCD Diecast Aluminum r� Q�}.Q STANDARDS l DIRECTIVES Solar Inverters IVGI ters NEMA 4X IEC 60068-2-11 Salt mist UL 1741 Second Edition,CSA C22.2 No.107.1-01 Transformerless (TL): 3.0 kW, 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW UL 1998 _ NEC 690.35,UL 1741 CRD IEEE 1547,IEEE 1547.1 Wide Operating Voltage Range:85-550V FCC part 15 Class UL 16998(type 1),NEC 690.11 Wide Operating Temperature Range:-13-158°F(-25-70°('i) UL 1741 CRD PVRSS,NEC 690.12(with SMART RSS) ANSI C12.1(meet 2%Accuracy) • High CEC Efficiency:97.5% - California Rule 21,HECO Compliant.IFFE1547 Integrated AFCI(Arc Fault Circuit Interruption) WARRANTY ��--- _ 10 years NEMA 4X plus Salt Mist Corrosion Protection Natural Convection Cooling Delta Products Corporation,lin¢ 46101 Fremont BW. FremDual MPPT(5.2kW/6.6kW/7.6kW) Sales t,CA 94538 sEmai:invertersales(±aldeltaww.can Compact and Lightweight Support Email:i rvene suppon@dN aww.can Sales t.&-.+1-877-040-5851 or+1-02E369-8021 UL 1741/IEEE 1547/IEEE 1547.1/CEC ca ® sSupportupport lw>�.+I-W442-41132-8019q`.A Monday to Friday from am AN ELEL■ Monday to Friday born 7 am to 5 pm PST(apart from Holidays) Listed/UL 1699B(Type 1)/NEC 690.11 c us ._, ''^SOlarCity ( ZepSolar Next-Level PV Mounting Technology ,`SOlarCity ZepSolar Next-Level PV Mounting Technology ZS Comp Components for composition shingle roofs ' 6 Mounting Block Array Skirt Interlock Part No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 4V Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules DMPP Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type V or"Type 2" Captured Washer Lag End Cap DC Wire Clip U� LISTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 850.1460 Listed to UL 1565 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 Engineered forspans up to 72"and cantilevers up to 24" jam • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No.850-1397 zepsolarcom zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1839-001 Rev D Date last exported:April 29,201611:22 AM Document#800-1839-001 Rev D Date last exported:April 29,201611:22 AM i - SPECIFICATION - MECHANICAL - - - _ Format 65.7 in x 39.4in x 1.57tn(including frame) (1670mm x 1000mm x 40mm) " �• - _Weight_ 44.09 lb(20.0 kg)._ e.r,,.�.P.�,rar:>•H.,.A r,. .+ Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology •� -+ Back Cover Composite film n.m •.,6m,m. Frame Black anodized ZEP compatible frame Cell 6 x 10 Q.ANTUM solar cells - _ -- Junction box Protection class IP67,with bypass diodes Cable 4 mma Solar cable;(+)47.24 in(1200mm),(-)47.24 in(1200mm) .>•b ,,,,,,�P ,,.,, Connector Multi-Contact MC4,IP68 mm r�,n�,T 0- POWER CLASS 275 280 285 - MINIMUM PERFORMANCE AT STANDARD TESTING CONDITIONS.STC'(POWER TOLERANCE+5 W!-0 W) - Power at MPP' PRPP (VII 275 280 285 Short Circuit Current` I,c [A] 9.35 9.41 9.46 1 I = Open Circuit Voltage` Va IV] 38.72 38.97 39.22 e Current at MPP' I- IA] 8.77 8.84 8.91 Voltage at MPP` VMPP IV] 31.36 31.67 31.99 The new R.PLUS-G4.1/SC is the ideal solution for all applications _ Efficiency' rl 1%] 016.5 x16.8 217.1 thanks to its innovative cell technology Q.ANTUM and the black Zep MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.NOC' CompatibleTM frame design for improved aesthetics, optimized material Power at MPP' P.11 IW] 203.3 207.0 210.7 E Short Circuit Current` Ise [A] 7.54 7.58 7.63 usage and increased safety. OAKUM was developed to achieve the best � Open Circuit Voltage` V. IV] 36.13 36.37 36.61 performance under real conditions - even with low radiation intensity Current at MPP` IePP [A] 6.67 6.93 5.99 and on clear, hot summer days. +, Voltage at MPP` VMPP (V] 29.59 29.87 .30.15 '1000 W!m.25T.spectrum AM 1.5G 2 Measurement tolerances STC s3%;NOC s5% '800 W/m�.NOCT.spectrum AM 1.5G •typical values.actual values may differ _._... - Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE LOW ELECTRICITY GENERATION COSTS At least 97%of nominal power during first year. Higher yield per surface area and lower BOS costs thanks to s a _iKwe ,«, r Thereafter max.0.6%degradation per year. - c Atleast92%of nominal power after to years. higher power classes and an efficiency rate of up to 17.4%. At least 83%of nominal power after 25 years. $ m All data within measurement tolerances. of INNOVATIVE ALL-WEATHER TECHNOLOGY Fwarranties in accordance with me warranty s a terms of the Q CELLS sales organisation of your Optimal yields,whatever the weather with excellent low-light espective country. and temperature behavior.Certified fully resistant to level 5 salt fog. IRRADIANCE(Wile) a o� a Typical module performance under law irradiance conditions in , ENDURING HIGH PERFORMANCE ew ~ comparison to STC conditions(25"C,1000 W/m2). l Long-term yield security with Anti-PID Technology', TEMPERATURE COEFFICIENTS Hot-Spot-Protect and Traceable Quality Tra.QTM. Temperature coefficient of Ix a [%/Kl +0.04 Temperature Coefficient of V. (3 [%/K] -0.29 GOMPq ;P Q�a E�Ls Temperature Coefficient of P_ Y [%/Kl -0.40 Normal Operating Cell Temperature NOCT [`F] 113±5.4(45±3°C) A RELIABLE INVESTMENT ti¢ 1 " Inclusive 12-year product warranty and 25-year 1 4r Maximum System Voltage V„, IV] 1000(IEC)/1000(UL) Safety Class II linear performance guarantee2. m,, ", COMPP� Maximum Series Fuse Rating (A DC] 20 Fire Rating C(IEC)/TYPE 1(UU c Max Load(UL)' [lbs/ft'] 50(2400Pa) Permitted module temperature -40'F up to+185'F y on continuous duty (-40°C up to+85°C) Phnfnn Load Rating(00' [lbs/(t'1 50(240OPa) 2 see installation manual i QCELLS 1 1 , 1 l7 1 1 Batt polymywlllna mlar module 2014 UL 1703;CE-compliant; Number of Modules per Pallet 26 aPRncz xxs IEC 61215(Ed.2);IEC 61730(Ed.1)applicalion class A - rx..w..w.. Number of Pallets per 53'Container 32 - DHPA /' Number of Pallets per 40'Container 26 ' APT test conditions:Cells at-1500V OVE Qw" PalletDimensions(LxWxH) 68.7inx45.Oinx46.Om - g EQagainst grounded,with conductive me- s AO• (1745 x 1145 x 1170mm) tal foil covered module surface,25•C, - -- ' Pallet Weight 12541b(569 kg) a THE IDEAL SOLUTION FOR: 168n 2 See data sheet on rear for further NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of - Rooftop arrays on ®Rooftop arrays on Ground-mounted information. this product.Warranty void if non-HP-certified hardware is attached to groove in module frame, v, residential buildings commercial/industrial solar power plants Hanwha Q CELLS America Inc. buildings C 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAIL inquiry®us.q-cells.com I WEB www.q-cells.us Engineered in Germany G CELIS Engineered in Germany CELLS TTTTTT TT TTTTT TTTTTTTITTITTTT�TTT THE INSPECTOR, LLC 5390 State Route I 1 Burke,NY 12917 1-800487-0535 wwwAheelectricalinspectoccom '1� •1-� �f,� I;•: Date:March 9,2017 Application No.On File:122401 L 10 7 20t7 THIS CERTIFIES THAT Martha McGeeLLOnly the electrical equipment as described below and introduced by the applicant named on the above application number in the preqc QUEENS-375 Ridge Road Town of Queensbury Contractor: Solar City DING In the following location: Basement I°Floor To Floor No.of Apt Garage Attic OutsideX Commercial ResidenceX Was examined on 3/8/17 and found to be in compliance with the re uirements of the National Electric Code. ' GFCI I Fixture Outlets I Receptacles Switches Fixtures Ranges I Cooking Decks Ovens Dish Washers Exhaust Fans Smoke/Heat Incandescent I Fluorescent I Other Amt. KW. Amt. KW. Ami KW. And. K.W. Amt. K.W. Detectors 1 Dryers Furnace Motors Dimmers Water Heaters Unit Heaters Multi Outlet Sys. Electric Heaters I Amt. I K.W. Oil I H.P. On H.P. Amt. Watt Electric oil Gas Am[ Rating No.of Feet Am[ K., Amt. KW. Amt. KW. Amt. KW. 1 1 1 Transformers I Alarm S stems Special Receptacle Panels Motors Signs Track Lighting Disposal ' Amt. I KVA I AN PS I Det Panel Amt. K.W. Amt. Na.of circuits Ratan Amt. H.P. AmL No.of Lams No.of Heads Amt H.P. J1 1 Service Disconnect Equipment Service J Amt. I Amp. I Type Meter 1 Phase 1 Phase 3 Phase 3 Phnse No.of CC. AWG. No.of AWG.of No.of AWG of 1\ 2W 3W 3W 4W Cond./phase CC.cond. Neutrals Neutrals HI-Le HI-Legs 1 11 NF J 1 Other Apparatus aus I—3800 an inverter 7-280 watt ants Manager J1 This certificate must not be altered in any manner;return to the office of THE INSPECTOR if incorrect. Inspector's credentials can be verified