Loading...
SOLAR-000049-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 at Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000049-2017 Date Issued: Tuesday, March 21, 2017 This is to certify that work requested to be done as shown by Permit Number SOLAR-000049-2017 has been completed. Tax Map Number: 266.1-1-15 Location: 94 OAK VALLEY WAY Owner: Lionel Barthold Applicant: Apex Solar Power This structure may be occupied as a: Solar Panel System 1105 s.f. No Rafter Upgrades By Order of Tov Board TOWN OF QUEENSSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, ���ryYYY Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 4FL 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000049-2017 Tax Map No: 266.1-1-15 Permission is hereby granted to: Apex Solar Power For property located at: 94 OAK VALLEY WAY In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Lionel Berthold Solar Panel-Residential $38,000.00 Owner Address: 94 OAK VALLEY WAY Total Value $38,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Demarse Electric 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Solar Panel System 1105 s.f. No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,February 23,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the a iration date. Dated at the Town Queens Th s ruary 23,2017 SIGNED BY: (((www...�_�"111��/// for the Town of Queensbury. Director of Building&Code Enforcement Office Use Onlv ACCESSORY STRUCTURE APPLICATION Received DATE 2/9/17 Tax Map ID TAX MAP ID 266.1-1-15 Permit No. So LAC - D(Z'000 ->-Ol''I- Permit Fee �'bo ZONING HISTORIC SITE —Yes —No Approvals SUBDIV/SION NAME Lot# APPLICANT Apex Solar Power OWNER Lionel Barthold ADDRESS 64 Main St.,Queensbury, NY 12804 ADDRESS 94 Oak Valley Way,Queensbury, NY 12804 PHONE (518)309-2786 PHONE (518)796-3713 CONTRACTOR Demarse Electric Inc. COST OFCONSTRUCTIOWEST/MATED}. $ 38,000.00 ADDRESS: 64 Main St.,Queensbury, NY 12804 BUILDING ADDRESS: 94 Oak Valley Way,Queensbury,NY 12804 PHONE: (518)309-2786 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE Greg Demarse(Demarse Electric Inc.) PHONE (518)309-2786 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.k. 20 floor sq.ft. I sq.ft. Height Boathouse with Sundeck 1E I ,� Deck i 'I Detached Garage(#of cars FFR y L� Dock Pole Barn OWN OF QUEENS UR Porch-open "Porch-3 season,Covered,Enclosed Shed Other Accessory Structure(s) 1,105 sq R(3 arrays) •'Considered floor area&must comply with FAR(floor area ratio)requirements if located In the WR zone DECLAR4770A I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application,plans and supporting materials are a true&complete statement description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that fAve are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: /Olivia Baitinrger Date: 2/9/17 Signature: i -�j�.�- Data: 2/9/17 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 86) . ex . : :. .. . . .. _ . January 26, 2017 Mr. Robert Reynolds Apex Solar Power 64 Main street 266.1-1-15 SOLAR-000049-201 Queensbury, NY 12804 Barthold, Lionel 94 Oak Valley Way Solar Panel Sys.(no upgrade)1105 s.f. RE: Solar Panel Project—Barthold Project OF QUEEBURY 94 Oak Valley Way,Queensbury, NY 12804 BUILDING DEPARTMENT Based on our Iimiteo examination,compliance with our comments shall not be construed as Dear Mr. Reynolds, Indicating the plans and s ations are in full compliance with the wilding Codes of New York State. I have completed the structural adequacy review for the above referenced project. I determined whether the existing rafters/roof support structure would adequately support the additional proposed solar system dead load in regards to flexure and deflection, as well as determined the required minimum resistance against anticipated wind uplift and shear loading for the roof mounting systems. According to the Site Visit Form provided for said project,the building of the roof structure proposed to receive the additional solar system dead load is a single family residence. The roof configuration, proposed panels and mounting systems are as follows: TOWN OF QUEEiNSBUi?Y BUILDING & CO ES T. • Roof Plane 1 (RP1) ReviewedPy:_ Date: Z k o Roof Structural System • 2x8 rafters spaced 16" on center, Southern Yellow Pine, No. 2 or better • Decked with 5/8" plywood and a single layer of asphalt shingle 2 ( /7 o Proposed PV Modules and Mounting System E v IE r'u ��J I' I' i Trinamount Modules(or equivalent) IronRidge Roof Mount System (or equivalent) • Roof Plane 2 (RP2) TOWN OF QUEENSBURY o Roof Structural System BUILDING& CODES • 2x10 rafters spaced 16"on center,Southern Yellow Pine, No. 2 or better • Decked with 5/8" plywood and a single layer of asphalt shingles o Proposed PV Modules and Mounting System • Trinamount Modules(or equivalent) • IronRidge Roof Mount System (or equivalent) 64 Main Street, Queensbury, NY 12804 6660 Joy Road, Syracuse, NY 13057 86) •• : •ape . . - .. - . A summary of my review follows: I determined the existing structural system dead loads and the additional dead load resulting from the proposed solar system. The controlling roof live load is snow loading and has been determined according to the requirements set forth in ASCE 7-05. The roof system was then checked against allowable flexural stresses and deflection limits for adequacy. Wind loads were also determined according to the procedures of ASCE 7-05. The resulting wind uplift and shear forces are included in the design calculations and may be used to determine the appropriate roof mounting hardware. In conclusion: The roof was inspected from the interior and exterior to determine the existing conditions. From my professional examination of this specific address, I determined that the existing roof systems RP1 and RP2 are adequate in regards to bending strength and deflection criteria to support the additional dead load of the proposed solar system in their current configurations. Please note that my review is of the rafter members only and is based solely on the information recorded in the Site Visit Form and correspondence with you. This review verifies that the information provided in the Site Visit Form is accurately portrayed and the building is otherwise in good structural condition and capable to resist the increased loading resulting from the proposed solar system. When selecting the roof mounting hardware,be certain to provide a watertight seal around all roof penetrations and in such a manner that normal roof drainage patterns are not impaired by the proposed solar system. While consideration was given to snow drifting, it is highly recommended that the project owner not allow excessive snow and/or ice buildup on the roof,as with any roof. Sincerely, Christopher W. Robert, P.E. OF NEW y P NER tv O y� �O? 9 -$- loom * . Olr f �� 9� � 1• 2 ZN�O,o 095395 9OFESSIONP 64 Main Street, Queensbury, NY 12804 6660 Joy Road, Syracuse, NY 13057 Y 518.309.2SUN(2786) a p•ex 315.629.9SUN(2786) Apexsolarpower.com Project Name: Barthold.uonel Project Address: 94 Oak Valley Way Queensbury,NY 12804 Roof Plane 1 Rafters Rafter Size= 2x8 Rafter Spacing= 16 inches on center Rafter Species= Southern Pine Grade= No.2 or better Rafter Height= 11.000 ft Rafter Btm Chord Length= 16.000 ft Measured Distance to Support= 7.000 ft Max.Rafter Span= 12.416 ft Total Rafter Length= 19.416 ft Roof Pitch= 8.250 :12 Roofing Roof Decking= Plywood Roof Decking Thickness= 0.500 inches Purlins= n/a Purlin Spacing= 48.000 Inches on center Roof Covering= Asphalt Shingle #of layers= 1 Solar Info Proposed Solar Module= Trinamount Proposed Mounting System= IRONRIDGE XRS Loading Criteria Ground Snow Load,PB= 60 Cold Roof? Yes Risk Category= II Terrain Category= B Exposure= Partially Building Height= <30 ft Basic Wind Speed,V= 90 MPH,3 second gust Deflection Criteria= 180 Roof Loading Summary Existing Roof Dead Load= 10.914 psf Additional Solar Dead Load= 2.971 psf Roof Snow Load= 29.453 psf Resulting Wind Shear Force= 122.90 lbs/panel Resulting Wind Uplift Force= 178.76 lbs/panel Strucutral Adequacy Roof Meets Bending Criteria= Roof Meets Deflection Criteria= Page 1 of 2 518.309.2SUN(2786) apex 315.629.9SUN(2786) I.v power Apexsolarpower.com Project Name: Barthold,Lionel Project Address: 94 Oak Valley Way Queensbury,NY 12804 Roof Plane 1 Roof System Dead Loads(DL)= 7.020 psf Rafter Weight= 3.776 lb/ft Rafter DL= 2.832 psf Roof Decking DL= 1.688 psf Puriin Self Weight= 0.000 Ib/ft Purlin DL= 0.000 psf Roof Covering DL= 2.500 psf Solar System Dead Loads(DL)= 2.971 psf Panel Dead Load= 2.671 psf Mounting System Dead Load= 0.300 psf Roof Snow Load(LL)(ASCE 7-10)= 29.453 psf Importance Factor,I,= 1.00 Exposure Factor,Ce= 1.00 Thermal Factor,C,= 1.10 Flat Roof Snow Load= 46.2 psf Cold Roof Slope Factor,C,= 0.638 Slope Roof Snow Load,P,= 29.453 psf Wind Load(Per ASCE 7-10) Directionality Factor,Kd= 0.85 Topographic Factor,K.= 1.00 Velocity Pressure Exposure Coeff.,K,= 0.70 Velocity Pressure,Q,= 12.34 psf Panel Length= 5.41 ft Panel Width= 3.25 ft Vertical Project Area,A„= 9.96 sf Horizontal Project Area,A,,= 14.49 sf Structural Adequacy Total Dead Load(DL)= 9.990 psf= 13.320 plf Live Load(LL)= 29.453 psf= 39.270 plf Resulting Moment= 1013.478 lb-ft= 12161.739 lb-in Section Modulus(5,,,)= 13.140 in' Resulting Bending Stress= 925.551 psi Load Duration Factor,Co= 1.15 Repetitive Member Factor,Cr= 1.15 Design Value for Bending Stress,Fy= 1500 psi djusted Design Value for Bending,Fy'= 1983.75 psi Elastic Modulus,E= 1.600 X 106 psi Deflection Criteria= 0.0690 ft Moment of Inertia(IQ)= 47.6300 in Resulting Deflection= 0.0308 ft Page 2 of 2 518.309.2SUN(2786) .... :,-:apex• 315.629.9SUN(2786) Apexsolarpower.com Project Name: Barthold,Lionel Project Address: 94 Oak Valley Way Queensbury,NY 12804 Roof Plane 2 Rafters Rafter Size= 2 x 30 Rafter Spacing= 16 inches on center Rafter Species= Southern Pine Grade= No.2 or better Rafter Height= 8.000 ft Rafter Btm Chord Length= 17.000 ft Measured Distance to Support= 10.100 ft Max.Rafter Span= 10.100 ft Total Rafter Length= 18.788 ft Roof Pitch= 5.647 :12 Roofing Roof Decking= Plywood Roof Decking Thickness= 0.500 inches Purlins= n/a Purlin Spacing= 48.000 Inches on center Roof Covering= Asphalt Shingle #of layers= i Solar Info Proposed Solar Module= Trinamount Proposed Mounting System= IRONRIDGE XRS Loading Criteria Ground Snow Load,Pr= 60 Cold Roof? Yes Risk Category= II Terrain Category= B Exposure= Partially Building Height= <30 ft Basic Wind Speed,V= 90 MPH,3 second gust Deflection Criteria= 180 Roof Loading Summary Existing Roof Dead Load= 10.914 psf Additional Solar Dead Load= 2.971 psf Roof Snow Load= 35.873 psf Resulting Wind Shear Force= 92.37 lbs/panel Resulting Wind Uplift Force= 196.28 lbs/panel Strucutral Adequacy Roof Meets Bending Criteria= Roof Meets Deflection Criteria= Page 1 of 2 ap�( 518.309.2SUN(2786) paex 315.629.9SUN(2786) Apexsolarpower.com Project Name: Barthold.Uonel Project Address: 94 Oak Valley Way Queensbury,NY 12804 Roof Plane 2 Roof System Dead Loads(DL)= 6.385 psf Rafter Weight= 2.930 Ib/ft Rafter DL= 2.198 psf Roof Decking DL= 1.688 psf Purlin Self Weight= 0.000 Ib/ft Purlin DL= 0.000 psf Roof Covering DL= 2.500 psf Solar System Dead Loads(DL)= 2.971 psf Panel Dead Load= 2.671 psf Mounting System Dead Load= 0.300 psf Roof Snow Load(LL)(ASCE 7-10)= 35.873 psf Importance Factor,I,= 1.00 Exposure Factor,Ce= 1.00 Thermal Factor,Ct= 1.10 Flat Roof Snow Load= 46.2 psf Cold Roof Slope Factor,C,= 0.776 Slope Roof Snow Load,P,= 35.873 psf Wind Load(Per ASCE 7-10) Directionality Factor,Kd= 0.85 Topographic Factor,K.= 1.00 Velocity Pressure Exposure Coeff.,K,= 0.70 Velocity Pressure,Q,= 12.34 psf Panel Length= 5.41 ft Panel Width= 3.25 ft Vertical Project Area,A„= 7.49 sf Horizontal Project Area,At,= 15.91 sf Structural Adequacy Total Dead Load(DL)= 9.356 psf= 12.474 plf Live Load(LL)= 35.873 psf= 47.831 plf Resulting Moment= 768.965 lb-ft= 9227.575 lb-in Section Modulus(S.)= 15.820 in' Resulting Bending Stress= 583.285 psi Load Duration Factor,Co= 1.15 Repetitive Member Factor,Cr= 1.15 Design Value for Bending Stress,Fb= 1500 psi djusted Design Value for Bending,Fb'= 1983.75 psi Elastic Modulus,E= 1.600 x 106 psi Deflection Criteria= 0.0561 ft Moment of Inertia(I„)= 88.99D0 in° Resulting Deflection= 0.0083 ft Page 2 of 2 PHOTOVOLTAIC SYSTEM EQUIPMENT: SYSTEM SIZE: 0 PV MODULES: (47)TRINA 275W DC/AC kW STC: 12.925kW\11.4kW INVERTER(S): (1)SE1140OA-US L9 OPTIMIZER(S): (47)SOLAREDGE P300 SCOPE OF WORK: GL INSTALLATION OF A SAFE AND CODE-COMPLIANT .�/ GRID-TIED SOLAR PV SYSTEM. E8 MO POiT INBT.LLLbUNEYEb RE0URE0> APPLICABLE CODES: 201:IRC CODE e 2015 NYS BUILDING CODE 2015 NYS RESIDENDAL CODE 2015 NYS PLUMBING CODE 2015 NYS MECHANICAL CODE Structural Only 2014 NATIONAL ELECTRICAL CODE of:NEWY SHEETINDEK P Y HER IV O PV-01 COVER AND PLOT PLAN oq 9 PV-02 SITE PLAN,STRINGS,BOM a m � y � W-03 MODULE LAYOUT Z = PV-O4 THREE.LINE DIAGRAM SITE PLAN 1/, NFO 095395 FESS10NPy E20 (� pgO SCALE: N.T.S. �ry( • µ � REVISION NOTES: DRAWN DATE PR0IECTNAME CLIENT: SCALE •'�.�: OueeMNy.NYt REV REVRY DATE DFSCRIPITON W. BARTHOLD•414E05 BARR101D,LIONEL • c" �,� RGR 12517 ROOF MOUNT 810AR VA Y WAY •R{ �:• a pex Fen S>TMu•e. Db3T CHECK 12825 WATTS OUEEN9WRY,NY 12M DRAWING 44��• aN6WcrolWoxame BY: DATE Solar Power UIp1E9O1M ER PLOT NUMB DRAWINOTTIfE COVERAND PLOT PLAN AV-01 AC DISCONNECT G INVERTER UTILITY METER —..— E]X0 vrtL MYVEWAY OBC BecOrvxEcr -p soon Maouu: QAC 01600HNECT O MMH JEItY)LE P.WEI®BSDrvB)kM BO% ® M�-MEfE0. ©MOMfdiW6 UNIT PV METER OCOMBINEA BO% ROOF OB8)BYC1KK1 AC DISCONNECT MAIN SERVICE PANE CUSTOMER INITIALS: ROOF 1 TILT:34- AZM:230' STRING 2 3 MODULES STRING 1 INVERTER 1 14 MODULES INPUT 2 INVERTER 1 INPUT 1 Structural Only SSOF NE4yY �P pNER W O ROOF 9 SO 9p 9'F TILT: 30' ¢� d AZM:50' p 9i _W STRING 3 8 MODULES ZFO OD59B5 INVERTER 1 p�OPESSIONP�� INPUT 3 ROOF2 TILT:2T AZM:23V II NOTES: sTwNGa 1. BOB TO BE LOCATED INTERNALLY ON WESTERN 12 MODULES SITE PLAN DETAIL WALL OF HOME NEXT TO EXISTING MSP. INVERTER 1 2. CONDUIT SHOULD BE RUN PARALLEL TO EXISTING INPlTf3 SCALE: N.T.S. WHENEVER POSSIBLE. AS�yg REVISION NOTES: DRAWN DATE: PR01ECtNAME: CIJEM: 7:p1vm02m Wamd.y.NY I]MM REV AEVBY DATE DERCRDTION BV' BARTRRD-4NJ08 DARiHOLD.UDNEL ::•a ex . A.NY1 RGR 12S1T ROOFI=WATTS DIOANVALLEYWAY • •: FVIB>Trd'�NY NOs) BY, 11H25 WATTS OU7E 71RY.NY 1]801. •. � kM(yFpnwAvpe.amP DY: :Solar Power r ISIByB9i)E6 M.NO0S DRAWRJO TITLE: JiFTE PLAN.BOM,NOTES -- — rRarERrvue ®worAREL LL,m OD=OI6LpNELf — uavEwAYAr pre9rscaaEcr Ba.mwa E ®E7Awxnoxeoz Q MVN SFMCE i.Wn UDMTYMEIEP® ©comew Iq MMR�,MEiFR QOMBMER BO% �ROOFO&9TM1LiKN CUSTOMER INITIALS: VENTILATION ACCESS ROOF 1 I ACCESS PATHWAY ROOF 1 Structural Only OF NE{yI, �P ,,?VIER W O CO y<o 9�1 ' a m W m i ZmmO 085395 X20 V gOFESSIONP —— ACCESS PATHWAY ROOF 3 ACCESS PATHWAYS ROOF 2—< VENTILATION ACCESS ROOF 3 NOTES: FIRE PLAN DETAIL 1. TWO FORMS OF ACCESS HAVE BEEN PROVIDED FOR ROOF 2.COMPLIANCE IS MET BY THE EXCEPTIONS IN SCALE: N.T.S. THE CODE. REVISION NOTES: DMwN nwiE: PROIECTNAME: a'FNr: scALe: e BY: OremAry,NY ItM1 REV REV BY DATE DETCRIPDON BARTHOID- 1080E SARTXOID,LIONEL •�� •�.• 66f0lq,RwJ RaR 1/25n7 ROOF MOUNT B/OAK VAVF'WAY .. .:.a e x BR3Nwu.NYll�f, •.+!••D• � u.�u� CHECTC 12838 WATTS OUEENSBURV,MAY t280a OMWINO BV: DATE: Solar Power Hs wga as sls ewTl3 NUMBER OMWMOIITLE: &FTE PUW,BOM,NOTES RV-02 SHINGLE ROOF,SPECS S- "`b 3• 3'-9' RAFTER SIZE: 2M1 2Y4 RAFTER SPACING(in): 16 'm ROOF MATERIAL: ASPHALT ARRAY I SPECS TILT rl: 9a AZIMUTH 17: 290 SQUARE FEET(82) 1475 Structural Only SOF NE `ala y�P�OpHEB W 9O•fl I G W ZN�Op 085395 X20 V FESSIOHP I' ,,. AMOUNTING DETAIL L SCALE: NTS ARRAY LAYOUT - ROOF 1 1 /AZIML/TH: SCALE: NTS ,�. \� IronRHp.%R-100 L-F FlBeNIp-Lox Comp We Shhgl Sl1fi' A p IMiriiwn 25'Ov.•E m.ha0m) _ 01 Spm REVISION NOTES: DMWN DATE: IMDECTNAME CLIENT: FKAM-- MYBYDATE DESCRRTION BY: BMTNOLD-011000 BAIVMm.LIONEL 65fi01�Y Rod RGR ,I28H7 ROOFMDUNT MGMVM1VWAY 0 :. p e x a5n aue NYIlM7.•• ••. CI@CK DATE: 12826 WATT8 DUEENSBURY,NY 12001Solarower , BY. 51&T6&3713 DMWNO TCI.@ — 7'' 16'-0• 7t SHINGLE ROOF 1 SPECS 14-10k' 5? RAFTER SIZE: 2%10 RAFTER SPACING(In): lie ROOF MATERIAL ASPHALT ARRAY SPECS TILT(ry: 27 AZIMUTH(•): 230 SQUARE FEET(W) 315 I Structural Only Of NE{yY A•P pNER IV O Co � > a n w W ZNFOq 095396 y6�2 �OEESSIO r,--ARRAY LAYOUT - ROOF 2 r AZIMUTH: SCALE: NTS a7a REVISION NOTES: DRAWN DATE: MOMCTNAME: CLIENT: SCALE:RBV REVRY DATE DESCIUTION BY: BARTNGUB-!10803 BART =.UONELA RGR 1/25/17 ROOF MOUNT 9dON(VP11EYWAY G ] 12B25WAM OUEENSSURY.W 12801 DRAWING • BY. DATR' 510.]863712Solar P DRAWMO'D1T.E: - - 1 SHINGLE ROOF i SPECS 0•-8 ' S{' e'-e' RAFTERSIZE: 2X10 RAFTER SPACING(In): 10 ROOF MATERIAL: ASPHALT ARRAY SPECS TILT r): 27 AZIMUTH 1230 sauARE FEET(IR) 315 ro y r Structural Only SOF NEIy P NER H. O g'�4GY 9 9f. U y G W Z�FOq 085396 x=32 V SSIONP r,-ARRAY LAYOUT - ROOF 2 1 AZIMUTH: SCALE: NTS y�Ayy� REVISIONNOTES: DRAWN DATE: PSOIECTNAMe CI.IPNT: SCALE • .•�:•. QYlmr�.y.NY iNmI REY REVBY DATE DERMWnON BY' BARTNOID-41308 BARTIgID.UONEL • • �,� RGR 1=17 ROOFMOLTrt �93DAXVA WAY .. .:. p e x RSPau NYLOT ..�•.:.. 12823WATIS OUEEN9BURY,NY123W ORAWIN6 uE+49ryv'oluO..Ra® BY: DAA' S16TBBJ1IJ NUMBER • Solar Power D13IOW41M DRAWMOTOLE: — IxvEmeR u9Eu-oxe wR EAcxlxnut Flw LTXC M mwoxxecr I WDUU!ElEe Cw WEMR"n S IxYFB]m*F IWAnoxs oEMDxco CNS ELECTRICAL KEY: ALLIOLAREDOEIIPID] MApMUMK.OPEIMnmcu R A1.6A 14nMI✓TSAR>Soo05Wl) ao4REo wll a s Mo EST2 DaoEMGN]EMP I'ck 31 11_ BREAKER Vqp.s50V NOMNLL OPENAnIp AC VOLTME tWV SIX1RT pRCUR WRRFM Nc): s]s MTEDWATTs1EALN1: 11Ma SWITCH vmv.sppJ wENGRcur VaLTAGE1-1 xs ACOFDunNCYOLTAaEM xw El SCREWTERMINAL NPIRS WITH NDEIIeN9c01malATKNq OPEMTNG WRREM IIAIPk a)s AC OPENATNGCURRENT W: n.s m FUSE • SPLICE IW-&VA oFERAnxc vDLTAGE NNPk 0u NUIBEROF Ian cwwNELs 1 w EARTH GROUND W.10.m WYER]Fn EFFIOMY: .910 T CHASSIS GROUND IxFVlswrtx Pl alwx•cDMamATpxa WTE.0 apepx4awT ---GEC I .law EGC be•2t.MA (8)#10 PV-Wire (6)#10 THHN (4)#6 BARE GRD (3)#6 THHN (3)#6 THHN (3)#4 THHN FREE AIR 3f4"EMHHN GRD (1)#6 GRD (1)#6 GRD (1)#6THHN GRD 314'EMT 3/4'EMT 3/4'EMT 1'EMT METER AC DISCONNECT ALL PANELS EQUIPPED WITH AC DISCONNECT 60AMP SERVICE SOLAREDGE P300 POWER NEMA 3R (INVERTER W/INTEGRATED ED 60AMP SERVICE RATED FUSABLE OPTIMIZERS SOLADECK INVERTER CONNECTS RATED NON-FUSIBLE (2)-60A FUSES DC DISCONNECTS r " STRING + . — _______ _ _ ,`�QINPUTI u Lz 14 MODULES �DC� -AC OUTPUT LOAD LINE 200AMSP LOAD LINE S 'L_________4f__ _— r STRING + — -- --- - `,VDCUT2 � 200A MAIN BREAKER 13 MODULES DC I ao i ALOADS ------------ STRING 2 + — ------- - DC= 8 MODULES DC I m INVERTER I I I STRING + L J 12 MODULES CDMA CELLULAR COMM.KIT GEC IRREVERSIBLY SPLICED TO EXISTING GEC OR BONDED DIRECTLY TO EXISTING GROUNDING ELECTRODE CONDUIT ELEVATION:V2 TO 3-12'=22-C HIGH AMBIENT TEMPERATURE:31•C 200 x 1.2=240 EXTREME LOW:-29'C 240-200(MCB)-40A SOLAREDGE SEI 14D0A4JS MAX CURRENT-47SA ROOFTOP AMBIENT TEMP:53'C=0.76 MAX ALLOWABLE AC PV BREAKER=40A MAX DESIGN CURRENT-47.5AX 1.25=59.375A=BOA BREAKEWFUSES CONDUIT RLL:/ 51 „5y� REVISION NOTES: DRAWN DATE: PROR:RNAME CLIFDIT: SCALE Qu=*M.NY12W REV REVRY DATE DESCRIPTION SY' SAK]HOL3-410905 BARTHOLD,LKINEL 66601uT RoW RQR 588115 ROOF MOUW 91 OAK VALLEY WAY F, IMWAM OUEENSBURY.NY 12501 DRAWING dei(518++Iwu�.cwe BY: DATE: 5161860113 NUMBER: Is19�R141]w DRAWO80 TDiE — Mono Multi Solutions THE � ■■■• ALLMAX P�U � ... MODULE 60 CELL MONOCRYSTALLINE MODULE 270-295W POWER OUTPUT RANGE a• Maximize limited space with top-end efficiency ` - Up to 180 W/m'power density - - Low thermal coefficients for greater energy production at high 1 Q V.0'7o operating temperatures MAXIMUM EFFICIENCY Highly reliable due to stringent quality control - Over 30 in-house tests(UV,TC,HE and many morel 0/e+5 W - In-house testing goes well beyond certification requirements POSITIVE POWER TOLERANCE a 100%EL double inspection As a leading global manufocturcr of Certified to withstand challenging environmental next generation photovoltaic products, conditions we believe close cooperation with . 2400 Pa wind load our partners is critical to success.With local presence around the globe,Trina - 54001'a snow load is able to provide exceptional service - 35 mm hail stones at 97 km/h to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strongbankable partner. We are committed to building srategic. mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solor Limited Comprehensive products and system certificates www.trinasolar.com - IEC 61215/IEC 61730/UL 1703/IEC 61701/IEC 62716 UNEAR PERFORMANCE WARRANTY - ISO 9001:Quality Management System sore.rvmmnw. nrv-25vearu-,.w-.w,.�n - ISO 14001:Environmental Management System - ISO 14064:Greenhouse Gases Emissions Verification - OHSAS 18001:Occupation Health and Safety Management System c �L us Ll O va C E 1 ��a PV CYCLE 115TER t\ V Trinasolar Smart Energy Together THE Ai IMAX©PLUS" MODULE PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-DDOSA.08(II) 275-295W Peak Power Watts-P,,.s(Wp)' 270 275 280 285 290 295 TSM-DD05A.05(II) 270-29OW Power Output Tolerance-PM.a(W) 0-+5 Maximum Power Vollage-VmrP IV) 31.2 31.4 31.7 31.8 32.2 32.5 Maximum Power CUrrent-IM..(A) 8.66 8.76 8.84 8.97 9.01 9.08 DIMENSIONS OF PV MODULE Open Circuit Volloge-vac(V) 38.4 38.7 39.0 39.3 39.5 39.7 unihnsm/Inches Short Circuit Cuff ent-Isc(A) 9.18 9.26 9.35 9.45 9.50 9.55 3s 941/370 Module Efficiency 4^(%) 16.5 16.8 17.1 17.4 17.7 18.0 Jwdbn Box ig SIC:Ieadiance 1000 W/m'.Cell Temperature 25°C.AIr Mass A M 1.S. +09'14 - - 'Test tolerance:S3%. ' In0W9 Hak I '. Nome0bin 1 g ELECTRICAL DATA(NOCT) U Maximum Power-P-(Wp) 201 205 209 212 216 220 o �A` 'A �3 Maximum Power V011Dge-Vun(V) 28.9 29.2 29.4 29.6 29.9 30.2 Maximum Power Curren)-lura(A) 6.96 7.02 7.10 7.17 7.23 7.28 e Open Circuit Voltage-Vec(V) 35.7 36.0 36.3 36.6 36.7 36.9 1 ya3 Short Circuit Current-li(A) 7.41 7.48 7.55 7.63 7.67 7.71 Gw 6n kk ' NOCi:trratliance 01800 W/nV.Ambient iemperatvre 20°C,Wind Speed i m/s. 11Cm�Hde � b`„ MECHANICAL DATA lain Solar Cells Monocrystalline 156= 156 mm(6 inches) 992/ .1 eockr Cell Orientation 60 cells(6=10) Module Dimensions 1650=992=35 mm 165.0 x 39.1 is 1.38 inches) SiI Sedonl Weight 18.6 kg(41.0 lb) 11/043 Larry mle Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass Backsheet White(DD05A.08(I1));Black(DD05A.05(11)) Frome Black(DD05A.08(11).DD05A.05(11)) Frame J-Box IP 67 or IP 68 rated 35n Je Cables Pholovollaic Technology Ca ble 4.0orm'(0.006 inches'). A 1000 mm(39.4 inches) Connector MC4 Compatible Or Amphenol H4/UTX Fire Type Type I or Type 2 I-V CURVES OF PV MODULE(295W) TEMPERATURE RATINGS MAXIMUM RATINGS ° Nominal Operating Cell 44'C(±21C) Operational Temperature -40-+85°C r Temperature(NOCT) 1000V DC(IEC) Temperature Coefficient of P.ux -0.39%/°C Maximum System Voltage IOOOV DC JUL) Temperature Coefficient of Voc -0.29%/°C Max Series Fuse Rating 15A Temperature Coefficient of iso 0.05%/°C e s 10 m m n x ss w a WARRANTY P-V CURVES OF PV MODULE(295W) Io year Product Workmanship Warranty 9° 25 year Linear Power Warranty mx/ (Please reler to product wo«only for deloils) T � F U g PACKAGING CONFIGURATION _ Modules per box:30 pieces i -'- � Modules per O'container:8a0 pieces E 0 ° 10 Is A n b n u . ~ •dY01 CAUTION READ SAFEIT AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trinasolar m 2016 Irmo Solar Limited.All riyhh reserved.SnaciOmtions indvtled in this dalosheet ore mbjecl to chon9e without notice. Smart Energy Together solar - • • = • SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US �pverler. '1225 m Walla �'oJra�a�• N 1.1 B .1 8 i f The best choice for SolarEdge enabled systems Integrated arc fault protection for NEC 2011 690.11 compliance Rapid shutdown for NEC 2014 690.12 — Superior efficiency(98%) — Small,lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL www,solaredge.us solar=eeSingle Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US SE7600A-US/SE10000A-US/SE114o0A-US SE3000A-US ISE380OA-USI. SESOOOA-US SE6000A-US SE7600A-US SE100009980 @ 208VA-US FSE11400A-US OUTPUT -- --- - �-- Nominal AC Power Output 3000 3800 5000 6000 7600 1 11400 VA .......... . . ........ ..... . ......... ......... . 0000 24ov Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ,, ,,,,,,,,,,,,,,,,,,,,, ....,,,....... .5450,@240V ,1,0950 @240V, .._........._.... ....._........ ................ ................ .................. ........... AC Output Voltage Min:Nom:Max."� 183-208-229 Vac _..........._........... ... .. . . ..... ......✓ ✓ ✓ ................ AC Output Voltage Min:Nom:Maz.ul .✓........ ........... 211-240-264 Vac ✓ ........................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min.Nom:Max of 59.3-60-60.5 Fiz ........................................... ................ Max.Continuous Output Current...... .....12.5......1..... 16......1...21 a(1.240V... .......ZS.......I.......32....... . 42 @_240V... .......47.5....... ....A..... GFDIThreshold 1 A .. tilit .Moni............................ .......................................................................................................................... ....Yes .. Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Powe r(STC ) 4050 5100 6750 8100 10250 13500 15350 W ........................g................. ................ ............... ................. ................ ................ .................. .................. ........... Transformer-less,Un rounded Yes Max.Input Voltage 500 Vdc ........................................... .......................................................................................................................... ........... Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc ........................................... ................ 16.5 @ 208V 33 @ 208V Maz.Input Currend�1 9.5 13 78 23 34.5 A dc ............... ............... .15:5, 240V. ................ ................ ..305 240V ............. rt Ci cuit . rren....... . ....... .@........ .................. ........... Max.Input Short Circuit Current 45 Adc ........................................... .......................................................................................................................... ........... Reverse-Polarity Protection yes Ground-Fault Isolation Detection 500kn Sensitivity . ................. ...... .. . ..... .... .. ... .... ........... .. ........ . ... .... Maximum Inverter Efficiency ....97,?. ....95:?..... ......98:3...... .....98:3...... ......98, ......98........ 98 % 97 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % ........................................... ...._...._.._ ............... ..98.@.240V.. ................ ................ ..97.5 @ 240V.. . ................. ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,AN51 C12.1 Optional ......................... ................. ................................................................................................................ ......... ........... Rapid Shutdown—NEC 2014 690.12 Yes STANDARD COMPLIANCE Safety _--_. d _..UL1741,UL36996 UL1999,CSA 222 G n47 d Connection Standards IEEE15 Emissions FCC ar[15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG rane 3/4"minimum/16.6 AWG 3/4"minimum/8-3 AWG . ..................................... ........... DC input conduit size/q of strings/ 3/4"minimum/1-3 strings/ AWG range 3/4"minimum/1-2 strings/16-6 AWG ............. ......_ ............. .. ... . ..... .._........... ............14 6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/ .(FI xD)................................ ................................ ....................I.... ......................... ..........775 x 315 x 260.......... ...mm.... Weight with Safety Switch............. ..........51.2/23. .7/24.7?.. ........�...................54 ... ................ ............88:4./90:1............. .lb/.ke... Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user ............... . ..............".____.. ....... ..... .replaceable). Noise <25 <50 d.. Min.-Max.Operating Temperature Ran a -13 to+140/-25...460(-40 to+60...... .available... 'F/'C .................................................................................. Protection RatingNEMA 3R ...................................................... ........... I'IPorower..ren.l...c eeoleatemmen swoft, i[Iintao I'I Ahigher mrrnntmote verter may bcused;ISNhe ONR2will limitW inprrersEnrr0 US002NNR2I. Rl 40 vertu P/N:SExuxAUSMNNU4 Ibora600W lworer E76MA US002 NNIJ41. NNa21. SUrISPEC ROHS 0 S.I.,Edg.Technologies to..All ughts mrc,wd.SOI-AREDGE.the S.taEdg.I.e.,OPTIMIZED BY SOI.AREDGE • solar - • • SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 • • �pawer 3� III � 25Vea�� PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL www.solaredge.us so I a r ' • • SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for high-power (for 72696-cell (tor thin film (tor641eil modules)__ 6p-tell motlules) modules) _ modules) INPUT Rated Input DC Power"' 300 320 400 405 W .... soiu................Inp'u'............... ....... ................................................. ............................ ............ Absolute Maximum Input Voltage 48 80 125 Vdc ..(Voc at lowest temperature)........... ........_........................._.................... ............._............. ...................... ..... .............. MPPT Operating Range 8-48 8-80 12.5-105 Vdc 1111. ......... .... 1111 1111... ... .. 1111 Maximum Short Circuit Current(ISE) 30 11,,. 10.1 Adc Maximum DC.Inpu[Current 12 5 I. 13 75 12.63 Adc 1111., 1111 ........... 1111 . .. ...... .. ..... . Maximum Efficiency..................... ......................................................99.5 % ....................................................... .............. Weighted Efficiency.................... _ ...................................98.8 _... 1111.%1111.. 1 11_.......—......................_.......... Overvoltage Category _ II _ ___ _ 1111 _ _... �__ .._ —__ - _ - -_ OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) _ Maximum Output Current 15 Adc m....... . 11 ............... ............................_................................. _.................... ............................ 1111 1111. Maximum Output Volta 60 _ I 85 _ Vdc_ OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC PartClass B,IEC61000-6-2,IEC61000-6-3 .. .1.09 .1... 1 .111. . .. Safety IEC62109 1(class II safety),UL1741 1111. . . 1111... 1111 . .._.. . _ 1111... . ....... ....__. RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters ...... .. ... .. .. . .. . .. ..... .. lzaxlszxns/ izsxisiX3s/ lz8xlszx4s/ Dimensions(WxLx H) Sx5.97x1.08 5x S.97xl.37 Sx 5.97x 1.89 mm/in ......... .. 1111.. 1111. .. .. Weight)including cables) .. 760/1 7 830/1.8 1064/2.3 gr,/,Ib .......................... ... .. ... .Input-Connector.... MC4 Compatible Output Wire Type/Connector Double Insulated MC4 Compatible ... .. 1111.. .. ... .......... Output Wire Length .... .... ..... . ...... ....0:95/30.. .. I ... .12/3.9... .. . .. . m(k 11,11.. 1111 1111 1111. .. .. Operating Temperature Range......... ............................................:40-+85/.-40_+185 -C/.'F.... ..............................._............... ...... lip Protection Rating .................... ................................................IP68/,...... Relative Humidity............_.......... .....................................................x.-.100..... .. 1111%1111.. ni Rated STC power of the module.Module of up to K%powertoleranre albwetl. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER121 Minimum String Length . ......._ ...............8._................ .......__......1..0.... .................1..8Power O .... . tiimize.s)............. .............. . ................. .............. Maximum String Length 25 25 50 ertimizers . P..ow......O..P..........)...................... ..................................... ..................................... ..................................... .............. Maximum Power per.5trin&........... ...............5250................ ...............6000................ ...............12750............... .....W.... .. Parallel Strings of Different Lengths or OrientationsYes __.......................................... .......... . .._... 1_111......_ _................................................................ .........1111. In It 9 npt allowed t0 mix P405 whh P3o0/P400/P600/m00 in entering. rC E (01 0 IRONRIDGE Roof Mount System ys "1 Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR10 Rail XR100 Rail XR1000 Rail Internal Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability • 12'spanning capability • Self-tapping screws • Moderate load capability Heavy load capability • Extreme load capability • Varying versions for rails • Clear&black anod.finish Clear&black anod.finish • Clear anodized finish • Grounding Straps offered Attachments — — -- — -- FlashFoot Slotted L-Feet Standoffs Tilt Legs AM Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware • High-friction serrated face • Works with vent flashing • Attaches directly to rail • IBC& IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware • Certified with XR Rails • Clear&black anod. finish • 4"and 7" Lengths • Fixed and adjustable - Clamps 8, Grounding - End Clamps Grounding Mid Clamps T-Bolt Grounding Lugs Accessories e z Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish&black anod. • Parallel bonding T-bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps • Mill &black stainless • Swivels in any direction • UV-protected polymer Free Resources - -- - - - _-_ __ _,- = Design Assistant x NABCEP Certified Training __ Go from rough layout to fully t Earn free continuing education credits, _ - engineered system. For free. while learning more about our systems. _— Go to IronRidge.com/rm T Go to IronRidge.com/training 0 2014 IronRidge,Inc.All rights reserced.Visit�vJromridgexom or call :,, ,��_ NORTH -1 Electrical Inspection, LLC NORTHEAST ELECTRICAL INSPECTIONS,LLC 65 Albermarle Road Scotia, NY 12302 PHONE: (518) 852-0826 (518) 866-1663 ELECTRICAL INSPECTION CERTIFICATION This is to certify that the electrical wiring and equipment which is introduced by the named applicant, is in the accordance with the National Electrical Code and local utility company. It also complies with the application on file at the date listed. Date of Final Inspection: 3/6/17 Job#: Barthold Applicant: Apex Solar .......___ Address: 94 Oak Valley Way D Queensbury, NY 12804 MAR 0 8 2017 Owner: Lionel Barthold TOWN OF OUEE_NSBURY Permit#: SOLAR-000049-2017 BUILDING 9 G,'>UES Equipment Installed (47) Trina 275W Modules (47) Solar Edge P300 Optimizers (1) SE 1140OA-US Inverter (1) Non-Fused Disconnect (1)Fused Disconnect (1)200A Main Lug Panel Steve Reynolds Electrical Inspector