Loading...
RC-000248-2015TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000248-2015 Date Issued: Monday, April 15, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-000248-2015 Tax Map Number: Location: Owner: 309.10-1-72 2 Richard's PL Melissa St. John Melissa St. JohnApplicant: This structure may be occupied as a: Residential Alterations 940 sq. ft. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement F Y TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 = Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000248-2015 Tax Map No: 309.10-1-72 Permission is hereby granted to: Dan Hunt For property located at: 2 Richard's PL In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Melissa St.John Single Family-Alteration $15,000.00 Owner Address: 31 American Way Total Value $15,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Dan Hunt 31 American Way Queensbury,NY 12804 Plans&Specifications Residential Alterations 940 sq.ft. Permit Renewed on 10/22/2018 for an additional year $ 200.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, October 24, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To u sbury 4 Fr d y %- ..-r 30, 2015 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 r Community Development- Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000248-2015 Tax Map No: 309.10-I-72 Permission is hereby granted to: Melissa St.John For property located at: 4 Newcomb ST,B in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Address: 31 American Way Single Family-Alteration $15,000.00 Queensbury,NY 12804 Total Value $15,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Dan Hunt 31 American Way Queensbury,NY 12804 Plans&Specifications Residential Alterations 940 sq.ft. PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,October 24,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of 000r, iday, to 15 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only DATE C - Received Tax Map ID TAX MAP ID _2504• Ico -- Permit No. �- p 2 fll5Sub&ic e Itm I . VIP ZONING a LS LI HISTORIC SITE _Yes ✓ No !Lj0U­EEN Q j 2t1 # SUBDIVISION NAMESBURY BUILDING & CODES TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS, INCLUDING SINGLE FAMILY DWELLINGS, DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED&MODULAR HOMES, BUBUT I `NOT MOBILE HOMES, THIS IS IN ADDITION TO THE PERMIT FEE. \ APPLICANT (prT 1 r 5 stn �kt o OWNER UY t I S-M ADDRESS ADDRESS .31 ArT2( mC --) t\,y is doppy Nob y PRONE/E-MAIL rjtf-, - 1ql -R1 .5 PHONE/E-MAIL.SIV - rqI -8In53 bac-)I ac-) Rt l(CI- COST OF CONSTRUCTION(EISA 7MATED): $�! 1� ADDRESS: 3I A fY`,�(1C�.Y1 L>AT_ BUILDING ADDRESS:''�1 b weuw( irnh S�nee-+ PHONE/E-MAIL _:�Co CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: t n PHONE GH61 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below New Addition Alteration 1°'floor sq. ft. 2n°floor sq. ft. Total sq.ft. Height Single Family qyv Two-Family Multi-Family (#of units Townhouse Business Office Retail - Mercantile Factory- Industrial Attached Garage (# of ) Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business Proposed use of building or addition Source of heat(circle one) rt C Gas Oil Propane Solar they Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? NO Are there easements on the property? NO Site Information a. Dimensions or acreage of lot , 02 ac cf-S b. Is this a corner lot? }0 c. Will the grade be changed as a result of construction Yes ✓ No d. Public water or Private well Ptb\t C, Looker- e. ookere. Sewer or Private Septic System _\ r".+akc seplirtc, 5 Value of all work to be performed (labor or materials) $ \ OC�C> DECLARATION: 1. 1 acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement/ description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. 1 also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: A"(-N DATE SIGNATURE: 1njw4 Ilfl(l DATE 2A-15 FOR OFFICE USE ONLY Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building & Codes Principal Structure Application July 2014 SEPTIC DISPOSAL PERMIT Office Use ON DATE 9 -9 - l 5 Received ,�nTax Map ID TAX MAP ID � .�� ' --11 Permit No. Permit Fee LOCATION OF INSTALLATION !'IPJ NeWCOmko —,LA9(-iG—T Approvals: APPLicAN r� r^' -ll`iCa �r)hn PHONE/E-MAIL 512) X11- crp�J ADDRESS ?AYtYYl Henca!1 iu.3N ubl INSTALLEWBUILDER: 1an " - PHONE/E-MAIL SKl�&P 21 'c7Q3 ADDRESS: pRyiy_rYCGr\ i )irl Q)pL ^ OWNER �\.JI1;liiissa s{A� PHONE/E-MAIL 5j$5'-IQI Address 31 R wi racs WtPf �l[` l__ 1i' ) CONTACT PERSON FOR BUILDING&CODESCOMPUANCE: 5..x..5.1 ttl.U►-F- PHONE 'AC( -or'1�� RESIDENCE INFORMATION r r Year Built #of bedrooms X Gallons per 69droom = Total Daily Flow 1980 or olcer 0 �.: Garbage grinder installed _Y ✓N 1981-1991 Spa or Hot Tub installed _Y N 1992-Present PARCEL INFORMATION Topography y Flat rolling _Steep slope _% slope Soil Nature v Sand _Loam _Clay Other Groundwater At what depth? Bedrock I Impervious Material At what depth? Domestic Water Supply ✓ Municipal Well(if well,water supply from any septic system absorption is_ft) Percolation Test Rate: per minute per inch(test to be completed by licensed engineering/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank Size JADDL gallons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hot tub) I System Type Absorption field with#2 stone Total length 160 ft.; Each trench_�x Seepage Pit with#3 stone How many: size _J Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size #of tanks _ Notes* 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received & approved. The installed system must match the septic system layout on file-no exceptions. DECLARATION: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage D' posal Ordinance. Print Name: (n?II�I� + civ. Dale: 0 4!o Signature: M3,V.01 1 4}SSav Date: 6 Town of Queensbury Building&Codes Principal Structure Application July 2014 WINDOW SCHEDULE CALCULATION SHEET Job Site Address: 14C-) Date �3-Cl - III Owner Application No. Window=or Man W.Name Model/Type Unit or Block N Rough Opening Rough Opening Sq.Ft.Vend Sq.fl.egress/ Clear opening Clear opening Special letter on plan Cell size Width Height dear opening width in Indies height In inches hardware or Instructions l 1?e l5�11 aLv 1a a It L Ittoto ay L I' to 1p ay3 to t. It 4" `' to l0 It Ii LAX1, 1. to c0 a� 1hLAIRII c� a4 to r7 It LA Iall a Town of Queensbury Budding&Codes Principal Structure Application July 2014 NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS CALCULATION SHEET Job Site Address: Date 8 Owner Application No. Habitable Rooms Area of Room in W-1 . Actual light square Required ventilation Actual Ventilation Sq.Ft.Opening for Remarks Square Feet footage 4%of room area Square footage Egress I4a3b a qea I tq 1 1• to '6aw)MOM LO .a r l0 5.d 9 Town of Queensbury Building& Codes Principal Structure Application July 2014 Generated by REScheck-Web Software Compliance Certificate Project ST JOHN RESIDENTIAL ALTERATIONS Energy Code: 2010 New York Energy Conservation Location: Warren County, New York Construction Type: Single-family Project Type: Alteration Climate Zone: 6 (7635 HDD) Permit Date: 10/01/2015 Permit Number: BP 2015-466 Construction Site: Owner/Agent: Designer/Contractor: 4B NEWCOMB STREET MELISSA STJOHN DAN HUNT QUEENSBURY,New York 12804 31 AMERICAN WAY 31 AMERICAN WAY QUEENSBURY,New York 12804 QUEENSBURY,New York 12804 518-791-8653 518-361-2931 Compliance: Passes Compliance: 0.5%Better Than Code Maximum UA: 186 Your UA: 185 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. meter Ceiling:Flat or Scissor Truss 810 38.0 0.0 0.030 24 Wall:Wood Frame, 16in.o.c. 806 26.0 0.0 0.052 36 Window:Vinyl Frame,2 Pane w/Low-E 69 0.290 20 Door:Solid 42 0.200 8 Floor. Unheated Slab-On-Grade 126 10.0 0.767 97 Insulation depth:2.0' Compliance Statement The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Vers' 5.5.0 and to comply with the mandatory requirements listed in the REScheck I spectign Checklist. \6 n Name-Title Signature Date Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 10/27/15 Data filename: Page 1 of 6 CREScheck Software Version 5.5.0 �J( Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.2 Construction drawings and Complies ]PRl]1 documentation sufficiently ❑Does Not demonstrates energy code ❑Not Observable compliance for the building ❑Not envelope. Applicable 103.2, Construction drawings and UComplies j 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code ❑Not Observable j ,d compliance for lighting and mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: Complies [PR2]2 sized per ACOA Manual 5 based - Btu/hr Btu/hr ❑Does Not -on loads per ACOA Manual J or Cooling: Cooling: other approved methods. ❑Not Observable Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 11 High Impact Mier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 10/27/15 Data filename: Page 2 of 6 Section # Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 Exposed foundation insulation ❑Complies [FO11]2 protection. ❑Does Not .—VI []Not Observable ❑Not Applicable 403.8 snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 JHIgh Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 10/27/15 Data filename: Page 3 of 6 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 Is listed and labeled as meeting []Does Not 'AAMA/WDMA/CSA 101A.S.2/A440 []Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures LIComplies [FR16]2 :'sealed at housing/interior finish - []Does Not and labeled to indicate&It;=2.0 []Not Observable cfm leakage at 75 Pa. ❑Not Applicable 403.2.2 !All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes,and ❑Does Not building cavities used as return ducts are sealed. []Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as OComplies - [FR15]3 ducts or plenums. []Does Not d' []Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R-_ R-_ UComplies [FR17]2 above 105 of or chilled fluids ❑Does Not below 55 QF are Insulated to R-3. []Not Observable ❑Not Applicable 403.4 Circulating service hot water R-_ I R-_ OComplies [FR18]2 pipes are insulated to R-2. []Does Not Ji ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are, EJComplies j - [FR19]2 installed on all outdoor air - ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Ter 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 10/27/15 Data filename: Page 4 of 6 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation labeled or ❑Complies [IN1312 installed R-values provided. []Does Not H, ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Ter 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 10/27/15 Data filename: Page 5 of 6 5ettl6n I Plans Verified Field Verified # Final Inspection Provisions Value Value Compiles? Comments/Assumptions 6, Re .ID 402.4.2, Building envelope tightness ACH 50 = ACH 50 =_ ❑Complies 402.4.2.1 'verified by blower door test result" ❑Does Not [FI17]1 of&It7 ACH at 50 Pa.This .�, requirement may instead be met []Not Observable 'via visual inspection,in which []Not Applicable 'case verification may need to occur during Insulation _ Inspection. 403.2.2 Duct tightness via post- _dm cfm Comply ies [FI411 construction with maximum ❑Does Not N, 'leakage of S dm to outdoors,or []Not Observable 12 dm across systems.For rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection,with maximum .leakage of 6 dm across systems and 4 dm without air handler. 403.1.1 Programmable thermostats UComplies [F]9]2 installed on forced air furnaces. ❑Does Not U []Not Observable ❑Not Applicable 403.1.2 'Heat pump thermostat installed LJComplles [FI1012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water EJComplies [FI1111 systems have automatic or ❑Does Not ,r accessible manual controls. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ElComplies [FI712 ❑Does Not J ❑Not Observable !, ❑Not Applicable 303.3 !Manufacturer manuals for DCompiles [FI1813 mechanical and water heating ❑Does Not .dequipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ST JOHN RESIDENTIAL ALTERATIONS Report date: 1027/15 Data filename: Page 6 of 6 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 26.00 Below-Grade Wall 0.00 Floor 10.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating Window 0.29 Door 0.20 Heating System: Cooling System: Water Heater: Name: Date: Comments Harvey P.Wolfers,P.E. CONSULTING ENGINEER 124 Broad Street Hudson Falls,New York 12839 (518)747-6385,Cell:(518)222-9677 harveypwolfers(a),roadrunner.com October 29,2015 Melissa St.John 31 American Way Queensbury New York 12804 Dear Ms.St.John Responding to the request of Dan Hunt, your contractor, I have this date, been to 4B Newcome Street to visually inspect the structural renovation of an existing residential dwelling. Selected photos,herewith enclosed,show the new and pre-existing structural details. Upon satisfactory completion of the structural renovation currently in progress, I have determined that the finished renovated residential dwelling shall be in compliance with the New York State residential code. S P .. V p, tyo a GLic.N 0 41.iqa. eriod ends J ly 31,2017 a �� S142h .��,•