Loading...
SOLAR-000077-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000077-2017 Date Issued: Tuesday, April 10, 2018 This is to certify that work requested to be done as shown by Permit Number SOLAR-000077-2017 has been completed. Tax Map Number: 315.10-1-13 Location: 20 QUINCY LN Owner: John Quaresima, Jeannie Quaresima Applicant: Apex Solar Power This structure may be occupied as a: Solar Panel System 770 s.f. No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the / property owner of the responsibility for compliance with Site Plan, 4 Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 ft- 011 BUILDING PERMIT Permit Number: SOLAR-000077-2017 Tax Map No: 315.10-1-13 Permission is hereby granted to: Apex Solar Power For property located at: 20 QUINCY LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: John Quaresima Solar Panel-Residential $38,000.00 Owner Address: 20 QUINCY LN Total Value $38,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Demme Electric 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Solar Panel System 770 s.f. No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,March 2,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Towny�Qee sbury; /� Thr a March 2,2017 SIGNED BY: \( Vt for the Town of Queensbury. V NA Director of Building&Code Enforcement Office Use Only ACCESSORY STRUCTURE APPLICATION Received DATE 3/1/17 Tax Map ID TAxMAP/a 7� 1� 1 -� Permit No. WUIVL-C'��t -20 1- Permit Fee ZONING Rec F )rt vis t v_J l`�20 HISTORIC SITE —Yes —No provals SUBD/VIS/ONNAME Lot# APPLICANT Apex Solar Power OWNER Jeannie and John Quaresima ADDRESS 64 Main St., Queensbury, NY 12804 ADDRESS 20 Quincy Ln, Queensbury, NY 12804 PHONE (518) 309-2786 PHONE (518) 636-5279 CONTRACTOR Demarse Electric Inc. COST OF CONSTRUCTION(ESTIMATED): $ 38,000.00 ADDRESS: 64 Main St., Queensbury, NY 12804 BUILD/NGADDRESS.- 20 Quincy Ln, Queensbury, NY 12804 PHONE: (518) 309-2786 CONTACT PERSON FOR BUILDING&CODES COMPUANCE Greg Demarse (Demarse Electric Inc.) PHONE(518) 309-2786 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 2n°floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck Detached Garage(#of cars_) Dock Pole Barn MAKIZZU11 I Porch-open ••Porch-3 season,Covered,Enclosed Iffig & CODES Shed Other AccessoryStructure(s) 770 sq ft (2 arrays) •• Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DEcLARAnoN I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application,plans and supporting materials are a true&complete statement description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I(we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: Olivia Baitinger Date: 3/1/17 Signature: Date: 3/1/17 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 COPY 1315.10-1-13 SOLAR-000077-2017 Quaresima, Jeannie & John UTAH OFFICES /ECT20 Quincy Lane Sandy Solar Panels (no upgrades) 770 s.f. Layton e n o i n e _ .. St. George Project Number. U1886-0564-171 DC G February 28,2017 D Apex Solar Power MAR 0 2 2017 64 Main Street Queensbury,NY 12804 TOWN OF OUEENSBURY ATTENTION: Chris Hall BUILDING & CODES REFERENCE: Jennie Quaresima Residence:20 Quincy Lane,Queensbury,NY 12804 Solar Panel Installation Dear Mr.Hall: Per your request,we have reviewed the attached layout and photos relating to the installation of solar panels at the above-referenced site. Based upon our review,it is our conclusion that the installation of solar panels on this existing roof will not adversely affect the structure of this house.The design of solar panel supporting members is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2016 Residential Code of New York State(2015 IRC)State and ASCE 7-10. Appropriate design parameters which must be used in the design of the su ortln memob _ connections are listed below: TOWIN OF Q BUILDING &Ground snow load:50 psf per the Residntial Code of New York StateE h $ Design wind speed for risk category H structures: 115 mph(3-sec gust) ReVieWed Bty o c20 Wind exposure:Category C1�wc�' ` �' Roof Structure:2x12 Rafters&2x6 Mnufactured Trusses @ 24 in O.C. Date�z c-6 Sm Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight relac wE xsolar panels is less than 3 pounds per square foot.In the area of the solar panels,no 20 psf live loads will bep . C=JL mRegarding snow loads,it is our conclusion that since the panels are slippery and dark,effective snow loads will likely w C7 d w .:G— be reduced in the areas of the panels.Solar panels will be flush-mounted,parallel to and no more than 6"above the roof Oz 3 surface. Thus, it is our conclusion that any additional wind loading related to the addition of these solar panels is E c�'m 8 m negligible.The attached calculations verify the capacity of the connections against wind,the governing load case. The OO m in mils shall be attached at 48"O.C.maximum with adjacent rails attached to alternating rafters using 5/16'diameter lag o a E-a screws with a minimum of 2.5"thread penetration into the rafter. air he� �fsartrelative gfnmust � rtle location oolpanelsis o rooedges. The paid of solar maximum panel support tabes provided by the m3._2z manufacturer is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables.Attachments to existing roof joist or rafters must be staggered so as not to over load any existing structural member. Waterproofing around the roof penetration is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Our conclusions are based upon our review of the photos and drawings which indicate that all structural roof components and other supporting elements are in good condition and are sized and spaced such that they can resist standard roof loads. Roof framing type,size,and spacing are as indicated in the attached photos and drawings by Apex Solar Power.A representative of Vector Structural Engineering has not physically observed the roof framing. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLC OF Ni;h, NY FIRM LICENCE:COA0012807 �.�Q'G�a T. 41� * ?0 0,P � � x * ct ¢ M f w 2 Roger T.Alworth,P.E. q 082749•`V t�G` Principal RTA/mrh 90FFSSIot P4 02/28/2017 9138 S. State St., Suite 101 I Sandy, UT 84070 I T (801)990-17751 F (801)990-1776 I www.vectorse.com E C T O R JOB NO.: U1886-0564-171 E rl O I n E E R S PROJECT: JENNIE QUARESIMA RESIDENCE SUBJECT: WIND PRESSURE Com onents and Cladding Wind Calculations Label: Solar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 115 Notes: Exposure Category: C Risk Category: II ADDITIONAL INPUT& CALCULATIONS: Height of roof, h [ft]: 25 (Approximate) Comp/Cladding Location: Gabfe/Hip Roofs 7*<0<_27" Enclosure Classification: Enclosed Buildings Zone 1 GCP: 0.9 Figure 30.4-213 (enter largest abs. value) Zone 2 GCP: 1.7 (enter largest abs. value) Zone 3 GCP: 2.6 (enter largest abs. value) a: 9.5 Table 26.9-1 z9 [ft]: 900 Table 26.9-1 Kh: 0.945 Table 30.3-1 Kn: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 27.2 Equation 30.3-1 GCP;: 0 Table 26.11-1 (largest abs. value) OUTPUT: P =9i,[(GCP)— GCP Zone 1 Pressure, p [psf]: 24.48 psf(1.OW, Interior Zones*) Zone 2 Pressure, p [psf]: 46.24 psf(1.OW, End Zones*) Zone 3 Pressure, p [psf]: 70.73 psf(1.OW, Corner Zones* within a) (*a=assumed=3') E C TO R JOB NO.: U1886-0564-171 E n O 1 n E E R S PROJECT: JENNIE QUARESIMA RESIDENCE SUBJECT: CONNECTION CAPACITY Lag Screw Connection Capacity: Demand: Lag Screw Size: 5/16 Ca: 1.6 Pressure Max Max. Trib. (0.6 Wind) Spacing Area Max. Uplift Embedment: 2.5 in (psf) (ft) (ft) Force (lbs) Grade: SPF (G = 0.42) Capacity: 205 lbs/in. emb. Zone 1: 14.7 4 12 176 Number of Screws: 1 Zone 2: 1 27.7 1 4 1 12 1 333 Total Capacity: 820 lbs Zone 3: 1 42.4 1 4 1 12 1 509 Demand< Capacity: CONNECTION OKAY E C TO R JOB NO.: U1886-0564-171 E n O I n E E R S PROJECT: JENNIE QUARESIMA RESIDENCE SUBJECT: GRAVITY LOADS CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original DEAD LOAD (D) pitch loading Roof Pitch/12 5.3 Composite/Asphalt Shingles 4.4 1.09 4.00 psf 1/2" Plywood 1.1 1.09 1.00 psf Framing 3.0 psf Insulation 0.8 psf 1/2" Gypsum Clg. 2.2 psf M, E & Misc 1.5 psf DL 13.0 psf PV Array DL 3.0 psf ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-10,Table 4-1 Roof Live Load With PV Array [psf] 1 012015 IBC, Section 1607.12.5 SNOW LOAD (S): Existing With PV Array Roof Slope (:12): 5.3 5.3 Roof Slope [°]: 24 24 Snow Ground Load, p9 [psf]: 50 50 ASCE 7-10, Section 7.2 Terrain Category: C C ASCE 7-10,Table 7-2 Exposure of Roof: FuFly Exposed Fully Exposed ASCE 7-10,Table 7-2 Exposure Factor, Ca: 0.9 0.9 ASCE 7-10, Table 7-2 Thermal Factor, Ct: 1.1 1.1 ASCE 7-10, Table 7-3 Risk Category: II II ASCE 7-10, Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-10, Table 1.5-2 Flat Roof Snow Load, pf[psf]: 35 35 ASCE 7-10, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]: 0 0 ASCE 7-10, Section 7.3.4 Unobstructed Slippery Surface? No Yes ASCE 7-10, Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-10, Section 7.4 Roof Slope Factor, Cs: 1.000 0.767 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, ps [psf]: 35 27 ASCE 7-10, Equation 7.4-1 Design Snow Load, S [psf]: 35 27 E C TO R JOB NO.: U1886-0564-171 E n S In E E R S PROJECT: JENNIE QUARESIMA RESIDENCE SUBJECT: LOAD COMPARISON Summary of Loads Existing With PV Array D [ps' 13 16 Lr[ps9l 20 1 0 S [psq 35 27 Maximum Gravity Loads: Existing With PV Array D+ L,[psf) 33 16 ASCE 7-10,Section 2.4.1 D+S [psfJ 48 43 ASCE 7-10,Section 2.4.1 Maximum Gravity Load [psfJ: 48 43 Ratio Proposed Loading to Current Loading: 89.3% OK The gravity loads in the area of the solar panels are decreased;thus,the stresses of the structural elements are decreased.Therefore,the requirements of Section 3403.3 of the New York State Building Code,2015 Edition (2012 IBC)are met and the structure is permitted to remain unaltered. PHOTOVOLTAIC SYSTEM EQUIPMENT: PV MODULES: (48)TRINA TSM275DD05.05(11) SYSTEM SIZE: INVERTER(S): (1�E760OA-US DC/AC kW STC: 13.2RW\13.6RW OPTIMIZER(S): (48)SOLAREDGE P300 SCOPE OF WORK: INSTALLATION OF A SAFE AND CODE-COMPLIANT GRID-TIED SOLAR PV SYSTEM. QUINCY LN *ECTOR 91]9 S.Sort SIFT.SYR IYI (SOLI 99PIJJ3 SUPT,�WYNMfbIJJ6! NEW ORRCOA:00J2W7J2BW STRUCTURAL ONLY 4�OF N't y'lpP TNALJJ,Y YES No .9 ,� PoiT M8TALL 5YNEYE5PE0N0.E9] i O m APPLICABLE CODES: Z V' $W 2016 20 CODE mO,o BBy1eS,t 20 2015 NYS BUILDING CODE ApAESSIOH2015 NYS RESIDENTIAL CODE 2015 NYS PLUMBING CODE 02/28/2017 2015 NYS MECHANICAL CODE 2014 NATIONAL ELECTRICAL CODE SHEET INDEX PV-01 COVER AND PLOT PLAN PV-02 SITE PLAN,STRINGS,BOM PV-03 MODULE LAYOUT PV-04 THREE-UNEDIAGRAM SITE PLAN SCALE: N.T.S. N MinhRt REVISION NOTES: DRAWN DA1E: MONCTNAME: RIItNT: SCALE: Qwml ,WU101 REV REVBY DATE DESMIPITON BY.. f]UMESIMA-414115) OUAREBIMA JENNIE -�i ••' 6660 M,RW RGR 221/17 ROOF MOUNT 2000INCYW .• .:.a ex EmNR YNYI OJ • •� BY: 1]200 WATTS OUEENSBURY.NY 12806 BM .• ••• yl�,�I��� BY: DATE 51BB.t8d2TB NUMBE0. Solar Power Euou]M DAA VoTTTLE:COVER AND PLOT PLAN FIV-01 KEY - - PPOPFRlYp E ®S"ma GC W0MO0 Ay ©BC NNEC7 GRNEWAY QAC SGGNN6GT INVERTER � SGURMGGUIE INVERTER O MNN 8E8NCE 9.WEL®®AINLTtMN BO% VIRDY MEIER ®MONRORMGUIIR AC SUMMING PANEL ® WMETER ECOMBIMER Box UTILFTY METER ❑ROOF GBB7RUCIgN CUSTOMER INITIALS: MSP AC DISCONNECT STRING3 2 MODULES INVERTER2 NPUT 1 ROOF TILT: 29- ROOF 1 AZM:183• TILT: 24' AZM:183• >WECTOR 91988.8••rtelilm,Burt lGl IBGII 99P1>l3 ewer,lllur BbJll 1801199PI ffe fu STRING BIM10BKOWL0012802 16MODULES STRUCTURAL ONLY INVERTER I INPUT 1 �E OF Ne/.l, •y'C��P T.�Y h m 9 } 0 ¢ i w N - 2 STRING ��0 08Pt49 ?O 11 MODULES INVERTER 9OFESS10WN5'� INPUT 02/28/2017 STRING4 NOTES: o MoouLEs 1. BOB TO BE LOCATED EXTERNALLY ON INVERTER2 SITE PLAN DETAIL NORTHEASTERN SIDE OF HOME NEM TO METER INPUT 2 2. CONDUIT SHOULD BE RUN PARALLEL TO EXISTING SCALE: N.T.S. kR WHENEVER POSSIBLE. L 61 AMw58b REVISION NOTES: DMwx DATE: VROIECTNAME: CLIENT: SCALE • O�mbuy,NN 12161 REY RBV BY DATE DF3CRIPTION BY: OUARESIMA-414657 011 MMA JENNIE •e•° RGR 2!21117 ROOFMOUNT 2000INCYUN apex 6E .NY1 • •• E.SBnrue.NY p65) CNBCK 16200 WATTS OUEENBBURY,NY 12604 pMWINO •• e•m ut.✓QMoe.wtupo.er.wm �.I DATE 618•B0m821Y NUL®ER: Solar Power s1 J03716 DMWDIOTITLE: SITE PLAN,BOM,NOTES RV-02 >�741' 2T-3' 4'-7t SHINGLE ROOF 1 SPECS �,S, RAFTER SME: 2X12 RAFTER SPACING(In): 24 ROOF MATERUU-' ASPHALT ARRAY 1 SPECS IT 1 TILT(): 24 (� AZIMUTH r): in SQUARE FEET OM) 385 *ECTOR vuv s.srtsrtm,sort rvr II9 1776Fs s.w..u...NM rsaNvvo-rvvs Fu NEWYORRCOA:Wl180) STRUCTURAL ONLY OF NF1,1,y yir �B T.,1... 2 W N =W y, �ORESSlotk � NNID 0228@017 Z MOUNTI SCALr TS j RRAY LAYOUT - ROOF 7 soar Mono � AZIMUTH: SCALE: NTS i ImnRHpe X{t.t00 RR LF FleaNrq-tqw ConpuSRe SMq 6/16'lAG (Midmum 26'SveW peM6BEM) H 64o5eva RmsION NOTES: DfIAWN DATE PRO)ECTNAME: CLIENT: SCALE: • Q•emYy.NY IL01 BEY May DATE DESCBRTTON BY' OUME W-41K T OUMESIMA JENNIE RGR 2121117 ROOFMOUNT 2001RNCY(N CHECK •• .. R. a p e x km SPr sc NY D011 13M WATTS GUEENS uw.NY 12W DRAWING BY: DAIS: Solar Power (513m 618-63662M NUMBER: ORAWMOTTIiF: — — 2-11 ' 1B•-M�• g SHINGLE ROOF 1 SPECS RAFTER SIZE: 2X6 iC-10' RAFTER SPACING On): 240C ROOF MATERIAL' ASPHALT ARRAY 1 SPECS TILT C): 20 AZIMUTH 1163 SQUARE FEET(R2) R66 *ECTOR eras s.smarm.surT for lsou vvo-n]s SINOV.W Zm 1199OIJJb FY NfW IDRR[OA�00121107 m STRUCTURAL ONLY SE OF Aw yyA,P��p T.q�Y 7 16'-B2' .yr �O•e BB2116•� rti `7 AOFFSSIONPy� 02/282017 r,-1ARRAY LAYOUT - ROOF 2 I AZIMUTH: SCALE: NTS REVISIONNOTES: DRAWN DATE: PRUNCTNAME: CLIENT: SC.RIE •ode Du®bq•NY 11105 REV REVBY DATE DFSCRiPt'IDN BY: OUARESIMA-/1115] O SIMA JENIE c o V �•� RGR 7121117 ROOF MWNT WWNCYLN •.6 O• X Fay Cyaee,NY 1305] • •• CNECI: 132OJ WATf3 'OUEENSBURY.NY I2NM DRAWING 0 ::. ..a BY: DAA: 55&83&52]0 NUMBER: Solar Power fraF1093)96 DRAWDIOTITIE — INVERTER LABELS-ONE FOR EACH INPIR PHOPOVOLTMC AC MCONIECT NODULE ELECTRICAL SPECIFlCATIONB INVER2RBPEpFlGTOHB OEBIO"comur1ONb ELECTRICAL KEY: ALL SOLAREDGE INPUTS MPJUMUM AC OPEMTND CURREM ]]A (<R)TWNA i51+3]SOWSDSN) SOLAREDGE BE)E004US HIGHEST]%M ORPH ZZ k 31 ft BREAKER VW.SEpy NOMINALOPEMTINOACVOLTAOE NW SHORT GRCUIT CURRFM AL<): 818 RATEDWATR (EACNI: zW0 Mx.MEAN E%INEMEANNUAL DBfcF -u �_ SWITCH Vm -50W PHOTOVq.TAJCA4018CONNECT OPEN pRCUR VOLTAGE ff=Y ]S.S ACOPERADNOVMTAOEM: ].10 INVERIER SPEORCAMONS O• SCREWTERMINAL IXPUR WITH ND STgNOCOMBBUTpNB MAAMUMACOPERATNOCURRENT 28A OPERADNG CURRENT OMPY B18 Ac oPElUDN6CURRENi w1: ]] SOLAREOGESEPPPPAVS m FUSE Iqp=81]A NOMINALOPEMDNOACVOLTAOE2bV CPERATNG VOLTAGE(VLP): 81A NNEER OF MPPiCWWNEIB 1 RATED WATTS IFACNI: 800P • SPLICE EARTH GROUND W-10.98A INVERTER EFFlpENOY; .880 ACOPERATINGV TAGEM: 240 m CHASSIS GROUND Ixvun WlTX(y slltlxOeoLYBMTXMB IMEGMTFD OC CISCIXII@CT AC0PERATINOCVRRENr1A1: u _—_GEC 1qp.18.54A NUMBER OF MPR CHANNELS 1 —EGC W-21.98A INVERTER EHRaENCY: .Wp INIE6IUTED Oc DISCONEGT 2xOIF<*Hlw OI M iMm GRD. IMno P✓Y.l� EM NIM WIE OND NIFtOINN RIEEAR I4MTBNORp WEM NEMA]RULMm eo ONROOF ]pLAREpOE9ENWy.Iy O11 a0i gVER1Ep ND11 FR[Dp/.Tm I mwww W gSCCIREGT9 L �W= _µ. I11"FF1NNORD oVIPVF TEMT g 1SWNGLF • _ --___Z _ 1,0 R2__ _ _______________T 1tMrouE9 -�PC ON. >= i Dln WNI DIAe IIIIx GRD uLMDdAe9EpmvED I PANEL]..vAr[t. Ac tx EMr vmm 9DIAReoDE DEUTAN i navADE wE1m P]LVOFlXORs Gw.•l NR INwKw I- BREAKER AG gSCURE E RATED SERVICE MiEDFV9FBLE (]1-BDL FU9E8 XE1M JNULUSIED SIX NROOF % SGLARETIDESEBWYLS qI ROOF IXY4RlEA NTIIIMECAATED ' 1NNSgw _l DCgBCONNECTB __ p�Ap _1 tW pMCOULEB L �`QIxM1ITt I p� -AC I ]MA MNX NiFN{ER OAF 111]uw _ B' _ EREAIQ0. I ' 191RND OF -Z �INRIT] LDID$ I IOMWULEB \_W a I 0 ALLMDgREAABON, BIXMMIOE 0SN LOMF 1 WIM CElLIIWi � Pb]OPINAEERS GMW.MR I / 1/ mq.NnlSre�c'R�m�FDiOPP CONDUIT ELEVATION:12 TO 3-12"•22'C SOLAREDGE SE60DOA-US MAX CURRENT=25A HIGH AMBIENT TEMPERATURE:31•C 200 x 1.2=240 MAX DESIGN CURRENT=25A X 125=31.25A=35A BREAKERIFUSES EXTREME LOW:-29'C 240-200(MCB(•40A SOLAREDGE SE7600IWS MAX CURRENT=32A ROOFTOP AMBIENT TEMP:53C=0.78 MAX ALLOWABLE AC PV BREAKER•40A MAX DESIGN CURRENT•32A X125=40A=40A BREAKERIFUSES CONDUIT FILL REVISION NOTES: WM DATE: PROJELTNAME ICLITM: SCALE: Q_-m ".NY IIM4 REV REVSY DATE DES7RB'TiON BY: OUARESIMA.414851 OUARESIMA.JENNIE wokya ROR SCONE ROOFMOUNT 2OOUNCYLN &j 18200WATIS OUEENSBUNYI NY IMOL DMWIND ulNlgEp¢NN1Wmnm BY: DATE: 518-00&fi21B MIMBPA (118A)O911M DRATJINGIITE: — Mono Multi Solutions THE ALLMAX "PLUS" MODULE 60 CELL MONOCRYSTALLINE MODULE 270-295W POWER OUTPUT RANGE Maximize limited space with top-end efficiency • Up to 180 W/m'power density - Low thermal coefficients for greater energy production at high 18.07 / operating tempernlwes MAXIMUM EFFICIENCY Highly reliable due to stringent quality control �t of • Over 30 in-house tests(UV,TC.HF.and many morel 0^"+5 W • In-house testing goes well beyond certification requirements POSITIVE POWER TOLERANCE • 100 o EL double inspection Certified to withstand challenging environmental conditions • 2400 Po wind load • 5400 Pa snow load • 35 mm hall scones at 97 km/h tilos 5olat LlmHed Comprehensive products and system certificates T: • IEC 61215/IEC 61730/UL 1703/IEC 61701/IEC 62716 LINEAR PERFORMANCE WARRANTY • ISO 9001:Quality Management System P.....w.,.. , :...,.�.....,,..,we., ..�r • ISO 14001:Environmental Management System _ • ISO 14064:Greenhouse Gases Emissions Verification • OHSAS 18001:Occupation Health and Safety Management System .:.......::...., . . .. 41 iii PV CYCLE rsrrn Trinasolar Smart Energy Together THE ALLMAX 4PLU5 MODULE PRODUCTS POWERRANGE ELECTRICAL DATA(STC) TSM-DD05A.08D0 275-295W Peak Power Wotts-P-,(Wp)• 270 275 280 285 290 295 TSM-DD05AASOIj 270-290W Power Output Tolemnce-Prux(W) 0-+5 Maximum Power Voltage-V-P(V) 31.2 31.4 31.7 31.8 32.2 32.5 Maximum Power Current-hon,(A) 8.66 8.76 8.84 8.97 9.01 9.08 DIMENSIONS OF PV MODULE Open Circuit Voltage-Vcc IV) 38.4 38.7 39.0 39.3 39.5 39.7 unif:mm/Inches Short Cimuif Cuaent-Im(A) 9.18 9.26 9.35 9.45 9.50 9.55 y ��m Module Efficiency n-)%) 16.5 16.8 17.1 17.4 VJ I8.0 R xndmpoc STC lrmdiance 1000 W/m'.Celliempemture 25°C.AIrMnSSAMI.$. tWas, - 'Test tolerance:±31%. M/ 1!y Nd Nonerl]le ELECTRICAL DATA(NOCT) Maximum Power-P-n IWp) 201 205 209 212 216 220 At JA e � 3 Maximum PowerVoBage-VNDP iVI 28.9 29.2 29.4 29.6 29.9 30.2 Y S Maximum Power Current-Imn(Al 6.96 7.02 7.10 7.17 7.23 7.28 ee Open Circuit Voltage-Vac IV) 35.7 36.0 36.3 36.6 36.7 36.9 sgxa Short Circuit Current-hs (A) 7.41 7.48 7.55 7.63 7.67 7.71 cioawaand. NOCi:Irradiance at 800 W/m',Ambient temperature 20°C.Wind Speed l m/s. 120-ed. y a MECHANICAL DATA tm/t Solar Cells Monocrystalthe 156 a 156 mm 16 Inches) eawcsihew Cell Orientation 60cells f6 x 10) Module Dimensions 1650-992*35 mm(65.0 x 39.1 x 1.38 inches) t mo,rsedml Weight 18.6 kg(41.0 Ib) Glass 3.2 mm(0.13 inches),High Transmission,AR Cooled Tempered Glass Backsheet White(DD05A.0B(U));Black(D005A.05(11l) Frame Black(ODOSA.08(ii).DD05A.05(Ill) J-Box IP 67or IP 68rated MAA Cables Photovoltaic Technology Cable 4.Omm'(0.006 inches'). Al 3000 mm 139.4 inches) Connector MC4 Compatible air Amphenol H4/UTX Fire Type Type I or Type 2 I-V CURVES OF PV MODULE(295W) TEMPERATURE RATINGS MAXIMUM RATINGS Nominal Operating Cell 44-C('2,C) Operational Temperature -40-+85°C Temperature(NOCT) IOODV DC(Il s Temperature Coefficient of PRAS -0.39%/'C Maximum System Voltage IOODV DC(UlJ Temperature Coefficient o1 Vac -0.29%/'C Max Series Fuse Rating 15A Temperature Coefficient of iso 0.05%/'C 0 0 6 10 16 N D vSb,x4 WARRANTY P-V CURVES OF PV MOD ULE(295W) IO year Product Workmanship Warranty 25 year Linear Power Warranty (Please refer to product warranty for details) FFE _ PACKAGING CONFIGURATION _ - � Modules per box:30 pieces �oA Modules per 40'container:840 pieces i a v+am x u ro n CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trmasolar m 2016 Trina Sold,limited.AN rights reserved.Specdcatlom included In this datasheet are subject to change without nonce. 5mart Energy Together solar - • . � • SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US IF7 �pvertp�' 25 s e i The best choice for SolarEdge enabled systems - Integrated arc fault protection for NEC 2011690.11 compliance - Rapid shutdown for NEC 2014 690.12 — Superior efficiency(98%) — Small,lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation - Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL www.solaredge.us so I a r • • Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US SE3800A-US SES000A-US I SE6000A-USI SE760OA-US I S_E30000A-US SE1140OA-US OUTPU-r Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ................ ............... . 10000 @240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 835010800 @ 208V 12000 VA ........................................... ................ . 5450 @240/.. . 10950 @240Y. .................. ........... AC Output Voltage Min:Nom:Max."r J ✓ 183-208-229 Vac ..................... ................ ............... ................. ................ . J J ...... l ...... ........ ........ ........ ........ ........... AC Output Voltage Min:Nom:Max.u1 I/ III, 211-240 264 Va[ . ......................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min:Nom:Max!'r 59.3-60-60.5 Hz Max.Continuous Output Current...... .....12.5......I......16......I..21_@.240V...I.......25....... .......3�.......I...?.82..@..240V...I.......475....... ....A..... GF DI Threshold 1 A ..........IDnit..ng,Is................... .................... bleT................................................................................................ ...-4es.... U01ity Monitoring,Islandin Protettlon,Country Configurable Thresholds Ves Yes INPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350 W ........................................... ................ ............... ................. ................ ................ .................. .................. ........... Transformer lessUngrounded......... .......................................................... Yes........................................................... ........... Max.Input Volta&e 500 Vdc .................... ...................... .................................................. ........................................................... ........... Nom.DC Input Voltage................. ................ ............... ............325 @,208V/.350 @ 240V,,,,,_, Vdc Max.Input Current1�1 9.5 13 16.5 @ 208V 18 23 33 @ 208V 34.5 Adc ........................................... ................ ...............I.15.S,�a 240V..I................ ................I..30.5..@.240Y..I.................. ........... Max.Input Short Circuit Current 45 Adc ........................................... .......................................................................................................................... ........... Reverse:Polarity.Protection............ ...........................................................Yes........................................................... ........... Ground-Fault Isolation Detection 600kv Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % 97 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % ........................................... ................ ............... .. .. ................ ................ ..9).:5.@.240/.. .................. ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication InterfacesRS485,RS232,Ethernet,ZigBee(optional) ........................................... ..............P ................................................ ........... ...... ........ Revenue Grade Data,ANSI C12.1 O tional3I ..... .................................... ............................................. ....................................................... ........... RaPId: Shutdown—NEC 201469012 Yes STANDARD COMPLIANCE Sa(etY................................... ........................................U1i741: .......UL3699B,..t1998,CSA 22.2 .......................................................... ........... Grid ConnectionStandards IEEE1547 ........................................... .......................................................................................................................... ........... Emissions FCC partly class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16:6 AWG 3/4"minimum/8-3 AWG .. . .... ... . ... .. ... .... .......... ........... DC input conduit size/4 of strings/ 3/4"minimum/1�3 strings/ AWG ran e 3/4"minimum/1-2 strings/16-6 AWG ...........g....................... .............14,6 AWG............. ........... ....... .................................................................................... Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.Sx12.5z10.5/ in/ ................................ ................................ ................................................... ..........775 x 335 x.260.......... ...mm.... Weight with Safety Switch............. ..........51.2/23 2..........I._...............,,54.7/24.7 88.4/40.1 Ib/kg,,. . .. ................ ..................................... . ...... Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user ........................................... .......................6..... re laceable Noise <25 <50 deA ........... .... .. .... ................................................................. ...................................................... ........... Min.-Max.Operating Temperature Rana . to.140/25to+60(40[..+60 ... available°) 'F/'C .... . Protection Rating NEMA 3R In For mercurrnt source may eeused,ace Sala verterEdge pport. I+1 Ahighe r current vett,may be used;theluvmle!will limlrItsW input current 0rhewlues stared. Isl Revenuegrade Inverterp/N:SExxxIA-0Sor 7600W lfar]GOOW Invener:SE]6W1.4), NNq]I. 1'I 40 version P/N:SExxxxhU50nONNUE(for]GOOW InverlecSE]600PLSgn]NNU41. suns PEC R 0 solar=@e SolarEd9 a Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 • • - Pn Grp 25Vea�s L rtantY i PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA-CANADA-GERIVANY-ITALY FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL www.solaredge.us so l a r " • t SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 ffor 6f4cell modules) (for high-power (for 72&96-cell (for thin film 60-ce1 1 modules) modules) modules) INPUT Rated Input DC Power"'................. ...........300__......................3 ......... 100 405 W ..20........._. ............ ............ ............ Absolute Maximum Input Voltage 48 80 125 .....Vdc..... (Voc at lowest temperature) ........... ......................................................... ............................ .......................................... -M PPT Operating Ran&e................. ........................$.:48......................... ..........$.-.80-..----.......-.-. 12.5:105............Vdc..... Maximum Short Circuit Current(Isc) 10, .........--11 10.1 Adc ........ . .. . . ................ ..... ............. ................ Maximum DC Input Current 12:5 .... .. „13 75 12 63 Adc Maximum EfficiencY... . ............. ......................................................99 5 . .................. .....%...... ............. .. ......... . ....... .. Weighted Efficiency...................... .. 98.8....................................................... .....%...... .......................................................... Overvolta a Cate or II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum output Current 15........................... ............................ ....Adc..... Maximum Output Voltage. ........... .........................................fio............ . 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC........................................ ............................FCC Part1S Class B,IEC61000.6.2,,IEC61000:6:3............................ .............. SafetY...................................... ....................................IEC62109-1(class II safety),.UL1741.................................... .............. RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed,System Volta&e... ......................................................1000...................................................... ....Vdc.... Compatible,inverters All SolarEdge Single Phase and Three Phase inverters ............................ . ............................ . ........................... 128x 152 x 27.5/ 128x152x35/ 128x152x48/ Dimensions(WxLx H) 5x5.97x1.08 5x5.97x1.37 Sx5.97x1.89 mm/in . ............................................. ......................................................... ............................ .......................................... Weight(including cables............... ......................760./1.7....................... ........530/1:8................1064/2:3........ ...&r./.16.... Input Connector MC4 Compatible -Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Len&th... ......... ......... 0:95_/3 0 ......... .....I.... ......... 12/3.9 m/.ft.... ........ ......... .... -Operating Temperature Range.-.-.--.- , -. _40: :+185 ............................ .................................................. Protection Rating . .............. ........................................ ..... IP68/NEMA6P Relative Humidity........................ . 0-100 %...... ..,roler.................................................................................................................. "'Ra[ed SiC power of the module.Module of up b r5%power loleeame allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERId Minimum String Length 8 10 18 ..(Power Optlmizers). ........ .................................... ..................................... .............. Maximum String Length 25 25 50 ..(Power.Optimizers)........................................................... ..................................... ..................................... .............. Maximum Power per Strin.8............ ...............5250.... ..............6000............... ..............12750............... .....W...... ........... . Parallel Strings of Different Lengths Yes or Orientations ............................................... ................................................................................................................. .............. m urs nm auww.d ro mix P4os with P3e0/P40vP6e0/no0 bone Mont. rCE 0% 0 IRONRIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested I PE Certified All components evaluated for superior ! Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rail: XR10 Rail XR100 Rail XR1000 Rail Internal Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 5'spanning capability • 8'spanning capability • 12'spanning capability • Self-tapping screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear& black anod,finish • Clear&black anod.finish • Clear anodized finish • Grounding Straps offered Attachments - FlashFoot Slotted L-Feet Standoffs Tilt Legs MRlu_ N� Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware • High-friction serrated face • Works with vent flashing • Attaches directly to rail • IBC& IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware • Certified with XR Rails • Clear& black anod.finish • 4"and 7"Lengths • Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps (j) T Bolt Grounding Lugs Q Accessories kit uAk s Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish & black anod. • Parallel bonding T-bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps • Mill &black stainless • Swivels in any direction • UV-protected polymer Free Resources Design Assistant ♦ NABCEP Certified Training Go from rough layout to fully 1wv Earn free continuing education credits, _— engineered system. For free. I•All, while learning more about our systems. _— Go to IronRidge.com/rm ♦ Go to ironRidge.com/training 02014 IronRidge,Inc.All rights nesemed.Visit�Jronfidqe.conn or call 1-OW-227-9523 for mom information.Version IA2 ili►� NEON THE%►o.ST InspectnnsLC NORTHEAST ELECTRICAL INSPECTIONS, LLC 65 Albermarle Road Scotia, NY 12302 PHONE: (518) 852-0826 (518) 866-1663 ELECTRICAL INSPECTION CERTIFICATION This is to certify that the electrical wiring and equipment, which is introduced by the named applicant, is in the accordance with the National Electrical Code and local utility company. It also complies with the application on file at the date listed. Date of Final Inspection: 3/31/17 Job#: Quaresima Applicant: Apex Solar Address: 20 Quincy Ln. Queensbury, NY 12804 Owner: Jennie Quaresima Permit #: SOLAR-000077-2017 Equipment Installed (48) Trina 275W Modules (48) Solar Edge P300 Optimizers (1) SE760OA-US Inverter (1) SE6000A-US Inverter (1) 100 amp AC Disconnect w/(2) 80amp fuses (1) 125 amp AC Summing panel w/(1) 40 amp breaker and (1)35 amp breaker Ca0v Asowaer Steve Reynolds Electrical Inspector