Loading...
RC-000365-2015 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 — Community Development-Building& Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000365-2015 Date Issued: Monday, April 4, 2016 This is to certify that work requested to be done as shown by Permit Number RC-000365-2015 has been completed. Tax Map Number: 308.12-1-32 Location: 100 BURNT HILLS DR Owner: Michael's Group Homes, LLC Applicant: Michael's Group Homes,LLC This structure may be occupied as a: Burnt Ridge Subdivision Lot 7,SFD 2305 s.f.,2-car attached garage 440 s.f. By Order of Town Board TOWN OF QUEEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804.5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000365-2015 Tax Map No: 308.12-1-32 Permission is hereby granted to: Michael's Group Homes,LLC For property located at: 100 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Michael's Group Homes,LLC Single Family-New $220,000.00 Owner Address: 10 Blacksmith DR, I Total Value $220,000.00 Malta,NY 12020 Contractor or Builder's Name/Address Electrical Inspection Agency Michael's Group Homes,LLC 10 Blacksmith DR, 1 Malta,NY 12020 Plans&Specifications Burnt Ridge Subdivision Lot 7,SFD 2305 s.f.,2-car attached garage 440 s.f. $1,377.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,November 27. 2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town` Q�u�eenn Jury; n Th a er 3,2015 SIGNED BY: �f�' (' for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATIOTll� OfficVn e Use ecel 01)6bFD Date: NOV 19 2L'13 Tax Map ID Tax Map ID 30�. lo? —�'�� ,rtPermit No. "�QUEEI Permit Fee 5 D)0"t=Ker-4r Zone :UILDING&CC =- _ Reg Fee Historic Site Yes X No Site Plan# Subdivision Name ycnW==M -L49tC, MG# Subdivision# Project Location loo iat "ius t.)a_,JC5 Y TOWN 80. RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,apartments,condominiums,townhouses,and/or manufactured&modular homes, but not mobile homes. This is in addition to the permit feels). Applicant Mv_vekeL%6 cigxLP}w LLL r Owner s IE Address io tal.kt -SlAMA pe.Nz Address MM.?A.,tvY 17-0 Z.O Phone/E-mail gV2>,g5q ,6-bA1 Phone/E-mail Contact Person for Building&Codes Compliance: TON`! L=CA.s:Gto Phone 5t0.'744.Z`+o'3 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2nd floor sf Total sf HJP Single Family X 1 'zzz 1,0 3 Z,30 6 3d- Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage / (1, 03, 4+) x 44o Other C� If commercial or industrial please indicate of business Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 Proposed use of building or addition 'S1MCiXZ FA AW4 fzes11»CE. Source of Heat(circle one) as Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning m lk Appliances &Chimneys Are there structures not shown on plot plan? No Are there easements on the property? No Site Information a. Dimensions or acreage of lot 1-65- 4c. b. Is this a comer lot? tio c. Will the grade be changed as a result of construction _ Yes _ No d. Public water or Private well puguc e. Sewer or Private Septic System seP C_ Value of all work to be performed (labor or materials) $__2_Z&,600_ DECLARA TION.- I. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to/the above:: PRINT NAME: ytTke �/. CiffG�a DATE: SIGNATURE: DATE: ii L For office use only Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: I 1/17 I IS Tax Map ID TAX MAP ID: Permit No. ZONE: Permit Fee 6M.3&S—ALJ( APPLICANT M\CHP.Et-S C.t(uxS V_ku teS, Iy,L PHONE/E-MAm 5\Q ,C&Cici 3U ADDRESS 10 C'S<AEaCsn.�rh-t I�tJ_, Iuh p.�NY 1207-0 INSTALLER/ CtPKZLeS F1Z4'Et>AAA'4 M*.4CAq.&M Nr'r PHONE/E-MAIL 5th. -14-7 .q 3'I 1 BUILDER OWNER MICHAimFi C..tlzrA.P VAOt eri' I V r S\$ -RACk . WWI ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: IW%.r LoC.Psc c) PHONE/E-MAIL -957-3 RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes �o 1981-1991 Spa or Hot Tub installed Yes !<No 1992-Present PARCEL INFORMATION Topography __2( Flat rolling _Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Z Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size ( Z5V gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length Z-O o ft.;Each Trench Y o Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all reuireements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: u T *°� f 6 5606 DATE: SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury, NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: 1111-711S Applicant Name: tw%C-" .Le-.s q¢c-,o "O" F' ,t i r TelephoneNo.: 'fAO.gJic,.t0-S11 Address to be Inspected too tauzwx 14uu s bru t= Return Address: %C, t wrt-*4 Z:z 14C, tua%;F�,Nw 1'].020 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED O Slight Swale O Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) O 12" O 15" ( ) 18" ( ) 24" O 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 00o 3(e �r-ao IS REScheck Software Version 4.6.1 Compliance Certificate Project PC552 - Aster Energy Code: 2010 New York Energy Conservation Location: Warren County, New York jU/ .�..,-.� ❑ `� l� j I Construction Type: Single-family liui^lu`I I' Project Type: New Construction NOV 1 9 2011 Orientation: Bldg. faces 45 deg. from North Conditioned Floor Area: 2,305 ft2 TOWN OF QUEENS_J BUR r Glazing Area 15% BUILDING & CODES Climate Zone: 6 (7635 HDD) _ Permit Date: 12 November, 2015 Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 100 Burnt Hills Drive The Michaels Group,LLC Queensbury, NY 10 Blacksmith Drive Malta, NY Compliance: Passes using UA trade-off Compliance: 2.2%Better Than Code Maximum UA: 363 Your UA: 355 The%Better or Worse Than Code Index reflects how close to compliance the house is based an code trade-of rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Foundation Wall: Solid Concrete or Masonry 266 0.0 13.0 0.052 14 Orientation: Front Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Foundation Wall:Solid Concrete or Masonry 296 0.0 13.0 0.052 14 Orientation: Back Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Ix 6030 Sliding Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 18 0.310 6 Orientation: Back Foundation Wall:Solid Concrete or Masonry 289 0.0 13.0 0.052 15 Orientation: Left side Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Foundation Wall:Solid Concrete or Masonry 304 0.0 13.0 0.052 15 Orientation: Right side Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Ix Std Basement Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 3 0.310 1 Orientation: Right side lx 6030 Sliding Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 18 0.310 6 Orientation: Right side Project Title: PC552 -Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Pagel of 8 Gross Area Assembly or Cavity Cont. U-Factor UA 1st Floor Walls:Wood Frame.24" o.c. 350 21.0 0.0 0.056 15 Orientation: Front 1x Home Office(AU):Vinyl/Fiberglass Frame:Double Pane with low-E 35 0.310 11 Orientation: Front Foyer#1: Solid 21 0.170 4 Orientation: Front 1x Dining (AU):Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.310 11 Orientation: Front 1st Floor Walls:Wood Frame, 24"o.c. 390 21.0 0.0 0.056 15 Orientation: Back 2x Great Room (E):Vinyl/Fiberglass Frame:Double Pane with Low-E 29 0.310 9 Orientation: Back 1x Great Room (R):Vinyl/Fiberglass Frame:Double Pane with Low-E 27 0.310 8 Orientation: Back 2x Breakfast(8):Vinyl/Fiberglass Frame:Double Pane with Low-E 19 0.310 6 Orientation: Back Breakfast#7: Glass 40 0.310 12 Orientation: Back 1st Floor Walls: Wood Frame,24"o .c. 315 21.0 0.0 0.056 16 Orientation: Right side Ix Great Room (F):Vinyl/Fiberglass Frame:Double Pane with Low-E 29 0.310 9 Orientation: Right side Ix Powder(AM):Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.310 2 Orientation: Right side 1st Floor Walls:Wood Frame. 24"o.c. 400 21.0 0.0 0.056 21 Orientation: Left side Mud#20: Solid 19 0.170 3 Orientation: Left side 2nd Floor Walls: Wood Frame,24" o.c. 342 21.0 0.0 0.056 15 Orientation: Front 1x Bed #3 (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.310 10 Orientation: Front 1x Foyer(BB):Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.310 5 Orientation: Front 1x Bed#4 (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.310 10 Orientation: Front 2nd Floor Walls:Wood Frame.24"o.c. 297 21.0 0.0 0.056 14 Orientation: Back 1x Master Bed (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.310 10 Orientation: Back 1x Bed #2 (U):Vinyl/Fiberglass Frame:Double Pane with Low-E 17 0.310 5 Orientation: Back 2nd Floor Walls: Wood Frame, 24" o.c. 324 21.0 0.0 0.056 18 Orientation: Right side Ix Bath(AM):Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.310 2 Orientation: Right side 2nd Floor Walls:Wood Frame,24" o.c. 342 21.0 0.0 0.056 19 Orientation: Left side 1x Bath(AM):Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.310 2 Orientation: Left side Ceiling: Raised or Energy Truss 1.222 38.0 0.0 0.025 31 Plant Shelf: All-Wood joist/fruss:Over Outside Air 28 30.0 0.0 0.033 1 Project Title: PC552-Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 2 of 8 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6.1 and to comply with the mandatory requirements listed in thREScheck Inec ption Checklist. /� _ . :G-- N a-Title Signture Date 'E'-_ t , �• V P11,«aMy yV 0683�� Vti p1��1- �SS Project Title: PC552-Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 3 of 8 REScheck Software Version 4.6.1 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, orthat an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Re .ID 103.2 Construction drawings and ❑Complies [PR111 documentation sufficiently ❑Does Not 0 demonstrates energy code ❑Not Observable compliance for the building envelope. ❑Not Applicable 103,2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code compliance for lighting and ❑Not Observable mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based Btu/hr— Btu/hr ❑Does Not on loads per ACCA Manual j or Cooling: Cooling: ❑Not Observable other approved methods. Btu/hr Btu/hr— ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 4 of 8 2010 New YorkFoundation Inspection Complies? Comments/Assumptions Ener 303.2.1 Exposed foundation insulation ❑Complies [FO11]2 protection. ❑Does Not to; ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 low Impact(Tier 3) Project Title: PC552 -Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 5 of 8 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not 4, AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not 14 and labeled to indicate&it;= 2.0 ❑Not Observable cfm leakage at 75 Pa. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR1311 air handlers,filter boxes,and ❑Does Not 8, building cavities used as return ❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. []Does Not 60 ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R-_ R-_ ❑Complies [FR17]2 above 105 9F or chilled fluids ❑Does Not 10 below 55 of are insulated to R-3. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water R-_ R-_ ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not J ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]' installed on all outdoor air -❑Does Not 0 intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact Merl) 2 Medium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: PC552 -Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 6 of 8 2010 New YorkInsulation Inspection Complies? Comments/Assumptions Energy � 303.1 All installed insulation labeled or ❑Complies (IN13]2 installed R-values provided. ❑Does Not 1' ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 7 of 8 Section Plans Veri R .ID fled Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & 402.4.2, Building envelope tightness ACH 50 =_ ACH 50=_ ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI1711 of&It:7 ACH at 50 Pa.This requirement may instead be met []Not Observable via visual inspection,in which []Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- _cfm _cfm ❑Complies [FI411 construction with maximum ❑Does Not 0 leakage of 8 cfm to outdoors,or 12 cfm across systems. For []Not Observable rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. _ 403.1.1 Programmable thermostats ❑Complies [Flg]2 installed on forced air furnaces. ❑Does Not /d ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not J ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [1,111]2 systems have automatic or ❑Does Not 10 accessible manual controls. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 El Does Not t� ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) j 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PC552-Aster Report date: 11/13/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\100 Burnt Hills Drive.rck Page 8 of 8 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.31 Door 0.31 Heating&Cooling Equipment Effic iency Heating System: Cooling System: Water Heater: Name: Date: Comments GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 p (� iL? 05/18/2016 Mr. Rich Schermerhom MAY 18 2016 U Schermerhorn Real Estate Holdings TOWN OF QU[EN116i 536 Bay Road Ste.2 BUILDING x CODES Queensbury,NY 12804 Inspection Address: 86A Gentry Lane, Queensbury, NY 12804 1-01 Report Number: 0518161 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/18/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including I"and 21 floor= 1,408 SF - Volume of the apartment,including 1"and 21 floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,103 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,103X60/11,876=5.6<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfa. Graf" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/18/2016 Mr. Rich Schermerhorn Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 86B Gentry Lane, Queensbury, NY 12804 Report Number: 0518162 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/18/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including 1"and 2'floor= 1,408 SF - Volume of the apartment,including I"and 21 floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,374 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,374X60/11,876=6.9<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, 5fa 1 Graf" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulfing, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/18/2016 Mr. Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 86C Gentry Lane, Queensbury, NY 12804 Report Number: 0518163 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/18/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including I"and 2nd floor= 1,408 SF - Volume of the apartment, including I"and 2"d floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,082 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,082X60/11,876=5.5<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, SjiX4�Gra4" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/18/2016 Mr.Rich Schermerhom Schermerhom Real Estate Holdings 536 Bay Road Ste. 2 Queensbury,NY 12804 Inspection Address: 86D Gentry Lane, Queensbury, NY 12804 Report Number: 0518164 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/18/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including 1"and 2'floor= 1,408 SF - Volume of the apartment,including 1"and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,209 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,209X60/11,876=6.1 <7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Siaw Graj" Stan Grainy, FE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 From: Stan Grainy SGRAJNY@NYCAP.RR.COM Subject: 100 Burnt Hills Infiltration Report Date: Today at 10:54 PM To: Tony LoCascio tlocascio@michaelsgroup.corn Cc: Joe Dolan jdolan@michaelsgroup.com House tested fine Stan Grajny,PE GRAJNY Consulting LLC. h�u://www.gr�jnyconsu �Itine•com/ 2��� 80 Andriana Lane Albany,NY 12204 Phone: (518)221-3240 agiajxjyjj'�zysO ro. rcom Air Leakage Property Organisatlari HERS Urkrr r, Grainy Ccreultirap LLC Ccritmred tW Oarnt Mlis D"m 518-221-3240 03170+16 Queensbury, NY 12t04 Stan Grarv, PE Rattre no:1110165 Rater ID:560922 Wealha:Albany.N7 Builder i0ol yntNdts The Michaels Urorp NntiseelsG p_lOOBrrrdthILs_NYE Sil_T2 033016.b1g Whole Nouse Infiltration Blower Door Test Heating Cooling Natsrak ACH 0.18 0.14 ACH 0 50 Pastas 2.64 2.64 CFM r,25 Pascals 827 d27 CFM 9D SO Pascals 1297 129' [ff.Leakage Arm Isq_ml 71.2 71.2 Speak Leakage Area 0.00014 O.OX14 ELA1100 sf shell Isq_tnl 1.09 1.09 Duct Leakage Leakage to outside units 011 CFM P 25 Pasc-as 0 MATS: Uotan 0.0000 CFM2S a CFA 0.0000 CFM per Std 152 WA CFM per Std 152 J CFA Ni A CFM Ia 50 Pascals 0 Eff_Linkage Area Isq.ml 0.00 Thermal Wiciency N1A Tota!Duct Leakage units CFJAIWCFA Total Duct Leakage 0.1160 NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 DV LS ,i MAR 31 2016 TP larch 30,2016 BUILDING&CODES Job #46257 New York State Dept. of Health 77 Mohican Street &� �C Glens Falls,NY 12801 RE: Burnt Ridge Subdivision Phase 2 - Queensbury(T), Warren County Lot#7 Septic System— 100 Burnt Hills Drive Gentlemen: This letter is to inform you that we inspected the completed septic system for the house at 100 Burnt Hills Drive (Lot#7) in the Burnt Ridge Subdivision on 1/19/2016. The septic system as installed was for a 4 bedroom house and consisted of a 1,250 gallon septic tank and 196 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr., PE cc: Dave Hatin, Town of Queensbury Eric Wilson, The Michaels Group G. .. s i.u.,.iu+ � .,.,.�.,.�. „,. �. .. .�� �.....,r,.�,.,,.•.. au,.,,,,u„i.,,a.,,u .,,u a.. .,aaa r,a,a, ,., au.u....0 .,�. .,...., .�, ., i....��, ,, �, .... .., i,i., .a,.,..aa,,., ..., Map Reference: Map Of A Proposed Subdivision Made For 1 Laric Development, LLC Dated:April 10, 2003 Janua ' Last Revised. ry 4 2014 By. Van Dusen & Steves / Filed: March 3, 2014, Plat C-349 i / LOT 6. 1 250 GAL. r SEPTIC TANK D15TRIDUTION BOX / 26.5 N °54 1.5� 4255WcY Water ` ABSORPTION i ' 5ervice TRENCHES k+ ° o 4 @ 49' EA. �� ro 1? Qo• I i z o ® C7 oy o f LOT 7 1 LANDS N/F OF 71,834:'81 sq. ft. ROBERT R. CLARK / 3915/63 f 1.65 acres I #100 Burnt Hills Drive Z // , ` 001, 14Y�?LOT 8 SEPTIC PLOT PLAN 000 1 HAVE SEEN OR OBSERVED ALL OBJECTS SUCH AS HOUSES, WELLS, TREES, FENCES, ETC U jr SHOWN,ON THIS DON IA8NT,I HAVE PERSONALLY t� !/ ” MEASUREE,DISTAD' c SET FORTH ON THIS IIAGW 1llf THOMAS R. SiGNA U; t10/ UA` / SEPTIC SYSTEM AS BUILT Y NAGE ENGINEERING • 'UNAUTHORIZED ACfCRA71Gf10 at arch 10, 2016 - 1"=40' D e: ,� RAp NIGNTOAS RVE( `Map of :a Survey made for - MAP BLARING A LICLN5ED LAND 51,R1,r BIORS SFX IS A _ S c a l e a = VIOLATION OF 5EC(ION 7209,5DB f}IVI51ON 2,Of THE NEW YORK.5TATC EDUCATION LAW! - 'ONLY COPIE5 FROM THE ORIGIN, Of Tb5DRVEY e S - MARKED WITH AN ORINSIDERED GINAL OF THE J��ID POPS LL/�./ $ SEAL SHPLL BE COTO BC�/pjf D TREE TREE CGPIES.• (� �T - H15 5 KVEYW 5INDICATED UDHEREONINCD NFYTHAT - D Q n i y�I �JI O Snyder _ � - - 7H15 SURVEY WAS PREPARED IN AC FDPhCE VATH THE i Rq,:/•• 1- - , . yors . and any -ve _ DYEYJ CODE OF PRACTICE FOR LFIG 5 f PROPR5 ADOPIONAL EO - ,i``1J` - BY THC LAND RV YORK STATE CK1WI AT16i!OF PROFESSIONAL I TO MT THE 5Uk'j E55h1N1RLNONLY ��� ®� TO THC PERSON FOR WHOM THC SL(<,`�Cf IS FREPAF.ED,AND _ - _ ON HIS BEHALF TO THE TITLE COMB-WI GOVERNMENTAL 169 Haviland Road Queensbury, New York - 12804 - AGENCY ANN LENDING IN5TNUITIOI{UJ TED HEREON.ME) _ Town of Queensbury, Warren County, New York 6 —BUILT Q y, TOTHE/551GNEE5OfTHE LENDING 1115TITUTION' l 0 03/30/1 SEPTIC SYSTEM AS Snyder (518) 792-8474 New York Lie. No. , 50135 N0. DATE DESCRIPTION DWG. NO, 9924 I-Lot 7 f Certificate of Electrical Compliance New York Atlantic-Inland, Inc. 997 McLean Road Ext. < 1i Cortland, NY 13045 Certificate No.:605182 Building Permit No.: Issue Date:3/29/2016 Building Permit Date: Inspected By: Devin Pratt Occupancy: R-3 OWNER SITE ELECTRICIAN Michaels Group LLC 100 Burnt Hills Dr Doug Alberts 10 Black Smith Dr Suite 1 Queensbury, NY 12804 Doug Alberts LLC Malta , NY 12020 Town of Queensbury 14 Park Dr Northville , NY 12134 SCOPE: New Single Family Home INSPECTION INFORMATION: ApplianceAMring supply/outlet: 1 - 120V 12A Dishwasher, 1 -120V .5HP Disposal Fans: 1 Range Fan-Light-Microwave, 5 Paddle Fan, 3 Exhaust Fan HVAC: 1 -240V 30A AC Condenser, 1 //`20V 8A Furnace Luminaires:44 Luminaires Outlets: 1 -250V 30A Receptacles-Other, 49 Switches, 59 Receptacles Service: Service Type: Underground, Service Size: 120/240V 10 200A Alarms/Mist.:4 Smoke Alarms, 4 Smoke/CO Alarms �C- 31,Q5.206 This certifies that the process noted above was complete as specified at the time of inspection and any conditions not within the scope of the inspection are excluded. Because there exists a multitude of proprietary specifications,the adherence to the relevant Building Code of New York State is applicable to the electrical requirements on the above noted date and valid for one year forward. In connection with areas at the time of inspection and does not constitute areas that are enclosed,concealed or inaccessible. Should the electrical system be altered in any way, including,but not limited to,the introduction of new electrical equipment,this certificate shall be null and void.This certificate only applies to the occupancy use as stated. Changes in use,or occupancy as indicated above,negates this certificate in its entirety. l Map Reference: 'Map Of A Proposed Subdivision Made For Laric Development, LLC i Dated:April 10, 2003 I Last Revised:January 4, 2014 / By: Van Dusen Steves Filed: March 3, 2014, Plat C-349 C LOT 6 �thbes. N79O 54T�5"ee c 425.46 ,too �'�fir water i Service Al - Q Ab. uv C7 t ee LOT 7 LANDS N/F OF ROBERT R. CLARK . 71,834.81 sq. 'ft. 3915/63 1.65 acres; #100 Burnt Hills Drive i CIA C14 LO 1 t CSV LO Covenants, Conditions,Easemen(s,Leases,Agreements Of Record !!! As Set Forth In Title Policy No. 15-14067 Lor g Written,By Stewart"Title insurance Company Y�? Dated:February 15,2016. 1)Utility Easement In Book 832 At Page 221-Does Not Affect Property 2)Utility Easement In Book 5182 At Page 169-As Shown 3)Maintenance Easement In Book 5298 At Page 229-Affects Islands Within Burnt Hills Drive And Lots 13&14 Only 4)Warranty Deed Book 5298 At Page 233-Burnt Hills Drive And :r a Wooden Lane TO Town Of Queensbury. 5)Declaration Of Covenants,Conditions,Restrictions,Easements rr - And Liens In Book 5298 At Page 238-Covers'Entire Subdivision {� d•, ,•- ": +,n1 °"i 'ti. m 6)Filed Subdivision Map-Referenced \ - °i 7)No Zone-Shown" 8)Cutting And Trimming Rights In Book 612 At Page 1057-May z'• ;.`a. t = `; Affect Lots 1,2,3&4 ' is RC 9)Drainage Easement In Book 697 At Page 1043-Does Not Affect Property "`.. 10)Declaration Of Covenants And Restrictions In Book 682 At " ' Page 1003-Does Not Affect Property `�f v , d> a, Note: Items listed in Book 832 at page 221,Book 697 at page 1043 and Book 682 at page 1003,refer toa map entitled`Burnt Ridge"Map of lands of Cobe,Incorporated, By:D.L.Dickinson Associates filed in the Warren County Clerks Once on May 13, 1986 as Plat A38. "Burnt Ridge"is not contiguous with"Burnt Hills Subdivision" or L 1 -Luzem ro arc a Road Subdivision" ision" ` u Date: March 10, 2016 Du .S _ EN5EDTILAND5UPVL1oF,5T5EA 5A� - .. Map of a Survey made 'for ,,.,.". a 40' .- •UNPUT110RRLDA -Scale 1,1 MAP BEON O AUC VIOLATION OF SECTION 7209,SUB-DIVISION 2,OF THE - � - - NEW YOKK STATE EDUCATION LAW.- 'ONLY COPIC5 FROM TNC OPJGINAI,CIF TH15 5URVLY - - ? - MARKED WITHLLB AN QF�GIN511)[EDT THE EAND SURVEYORS - v - S'CE 5N IC B[CONSIDERED TO BE'/A,UD TRUE COPIES.'S -Le �\ - 'CERTIFICATION5 INDICATED IN AC1;j 51GNIFY THAT - - Dam ® - Tt115 SURVEY WAS PRL PARED IN AC46p,DAI.IC[WITH THE - .L/),+.•,�l Ja/ 4t•'•/ ' 7 EX15TING CODE OF PRACTICE FOR V1,0 SURVLYOR5 ADOPTED - - - BY THE NEW WRK AT!glj OF ir-ve .v - LAND 5URVEYOR5.5AIDC RTI�CATIGjj95HALL RUN OIN.'LY - gg%% SHEET 1 1 TO THE PER50N FOR WHOM THE SUR'''&15 PREPARED,AND ON HIS BEHALF TO THE N TLE COMPAjf'�;GOVERNMENTAL - - - - AGENCYAND LENDING INSTITUITION UYIED HEREON,AND Q e Warren 'p w York np E _ 169 Haviland Road Queensbury, New York 12804 TOTHCA551GNEC50FTHCLENDING)IiYIITUT10N' 1 ur,J 7 nt � ,moi. 1 Town of ue nsb n Cou Ne Y "' _ n w q O 9924 (518) 792-8474 New York Lie. No. 501.35 ""ANO. DAT9 �� j DESCRIPTION �wG. N i-got _. „ MAR 3 t 2016 d5 I T 0 8908 4 r BUILDING .......&CODES `