Loading...
RC-000092-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000092-2017 Date Issued: Wednesday, August 23, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000092-2017 has been completed. Tax Map Number: 296.14-2-26 Location: 70 DEVIN CT Owner: CERRONE BUILDERS, INC. Applicant: CERRONE BUILDERS, INC. This structure may be occupied as a: Single Family Dwelling w/FP 1442 s.f., Go 400 s.f. By Order of Town Board Village at Sweet Road, Lot 26 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve theCasa..o 4 ,ott-- property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000092-2017 Tax Map No: 296.14-2-26 Permission is hereby granted to: CERRONE BUILDERS,INC. For property located at: 70 DEVIN CT In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: CERRONE BUILDERS,INC. Single Family-New $305,000.00 Owner Address: 1589 State Route 9 Total Value $305,000.00 Fort Edward,NY 12828 Contractor or Builder's Name/Address Electrical Inspection Agency CERRONE BUILDERS,INC. 1589 State Route 9 Fort Edward,NY 12828 Plans&Specifications Single Family Dwelling w/FP 1442 s.f.,Garage 400 s.f. Village at Sweet Road,Lot 26 $0.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,March 23,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eensb [ / dors y 017 SIGNED BY: /•V! for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICA 2 2 Only ✓ �+ , Date: u�- b _ 1 7 LS LSIPe i o , , , _ OOob c 2- ( � Tax Map ID '196 . 14 - 2- L(� J[2Zone Historic? _ es I 'SubdivisionName V. II Ai Swi f- �D. TI�y an COMMUt IT C EA l4isi n# Project Location 1; pEJ;nl C'4- o TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This Is In addition to the permit fee(s). Primary Owner(s) CEKp—onIE � Ide�- Address 151 9 91-1-. 9 -F+, dY /RFo28 Phone/Email 6,119 361 - 633 1 ClR2o Jc guy 61 5 iNC 6M't-: 1. Coe" Applicant Address Phone/Email Contractor SaMc Address Phone/Email Contact Person for Building&Codes Compliance: _qrEVf.'l ezift'/E Phone 36/ -633 1 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1"floor sf 21 floor sf Total sf Height Single Family II44d— 114No2 30 Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1,P3, 4+) 900 Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Res: •,r,— Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Rar;pl—_ Are there structures not shown on plot plan? tj o Are there easements on the property? sJ o Site Information: a. Dimensions or acreage of lot •ag Ac s b. Is this a corner lot? _Yes No c. Will the grade be changed as a result of construction Yes _No d. Public water or Private well(circle one) Public Private e. Sewer or Private Septic System(circle one) ewer Private Value of all work to be performed (labor or materials) $ 305, 0 0 0 DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above:: PRINT NAME: S i / l rRPo Jc DATE: c3 - 7 — /7 SIGNATURE: DATE: 3 — 17 For office use only Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: .3 —' 6 — 1 -7 Tax Map ID TAx MAP ID: 9 b . f y — oL —oZ 6 Permit No. Permit Fee ZONE: OWNER PHONE/E-MAIL ADDRESS INSTALLER/ PHONE/E-MAIL BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL �7 BUILDING ADDRESS ROOM OF INSTALL: PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: M�ies-r:C _ ; Model#: QuA,2'r7_3 2 i n/ Listed by: t- L Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK _BRICK _STONE Flue TIE STEEL Size in inches Material _DOUBLE WALL TRIPLE WALL _INSULATED ** If non-masonry provide manufacturer name: MA j ; c ;Model#: -tQT 2_ 3 sL;d DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINTNAME: i "z&6 DATE: SIGNATURE: DATE: 7� Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: 3- 6 — 17 Tax Map ID TAx MAP ID: 029 to . l y— .2 — b Permit No. Permit Fee ZONE: APPLICANT PHONE/E-MAIL ADDRESS INSTALLER/ PHONE/E-MAIL BUILDER OWNER ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL RESIDENCE INFORMATION Year Built #ofbedrooms X gallons par bedroom =total DailyElow 1980 or older Garbage grinder installed Yas No 1981-1991 Spa or Hot Tub installed Yes No 1992-Present PARCEL INFORMATION Topography Flatrolling _Steepslope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size _gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length R;Each Trench Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: _Vlff ��� ��� DATE: 3 b — SIGNATURE: �� DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R.Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: n� " 7 — 1-7 Applicant Name: l G(C2orl i &A d e�S Telephone No.: 518 R1 - 6331 Address to be Inspected -70 OEd A C4-- ReturnAddress: 0589 Rt. 9 P+_ EmAP.6l 4y I9faP Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) IS" ( ) 24„ ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R.Van Ness,Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 REScheck Software Version 4.6.2 Compliance Certificate Project Cerrone Builders Inc 296.14.2-26 RC-000092-2017 Cerrone Builders Energy Code: 20151ECC 70 Devin Court Location: Warren County, New York 1424 s.f. SFD w/400 s.f, garage & gas FP Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,442 ft2 Glazing Area 16% Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 70 Devin Court VISION Engineering, LLC Lot 26 206 Glen Street Queensbury, NY 12804 Suite 56 Glens Falls, NY 12801 (518)792-9264 Compliance: Passes using UA trade-off Compliance: 1.1%Better Than Code Maximum UA: 264 Your UA: 261 The%Better or worse Than Code Index reflects how close to compliance the house is based an code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minlmum<ode home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling 1: Raised or Energy Truss 1,442 38.0 0.0 0.025 36 Wall 1: Wood Frame, 16"D.C. 1,602 21.0 0.0 0.057 76 Window 1:Vinyl Frame:Double Pane with Low-E 194 0.290 56 Door 1: Front:Solid 20 0.200 4 Door 2: Back: Glass 40 0.290 12 Door 3: Fire Door:Solid 18 0.140 3 Basement Wall 1:Solid Concrete or Masonry 1,388 0.0 15.0 0.046 62 Wall height: 7.8' Depth below grade:6.8' Insulation depth: 7.8' Window 2:Wood Frame:Double Pane 7 0.400 3 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.320 5 Door 4: Solid 18 0.200 4 Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 1 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6 and to comply with the mandatory requ' en isted in the REScheck Inspection ChecckL(((liiststt. Name-1UT�itle Xign DatA Project Notes: VISION Project 1216 SOF rayl LW. Rp /� _r n 2 W UlW OF SS NP Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 2 of10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck w REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.iD 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate []Does Not [PR111 energy code compliance for the k. building envelope.Thermal ❑Not Observable envelope represented on i❑Not Applicable construction documents. _ 103.1, '..Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for (PR3]1 lighting and mechanical systems. ❑Not Observable I Systems serving multiple ;❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, l Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual s based Btu/hr_ Btu/hr ❑Does Not (PR2[2 ,,.,on loads calculated per ACOA Cooling: Cooling: ❑Not Observable Mr Manual J or other methods Btu/hr— Btu/hr— approved by the code official. ❑Not Applicable j Additional Comments/Assumptions: I I High Impact(Ter 1) 2 1 Medium Impact(Tier 2) J 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 3 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 .Conditioned basement wall R-_ R- ❑Complies See the envelope Assemblies [F0411 insulation R-value.Where interior R_ R- ❑Does Not ;table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. _ 303.2 ':Conditioned basement wall ❑Complies (FO511 'insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable :❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ❑Does Not ;table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FOM'- to protect exposed exterior ,❑Does Not insulation and extends a minimum of 6 in. below grade. []Not Observable []Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not _. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1', t(Tier 2) '':;. Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 4 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans".Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions _& Req.ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U__ ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable j [FR211 303.1.3 '..U-factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or n ".❑Not Observable taken from the default table. -- " ' ❑Not Applicable j 402.4.1.1 IAir barrier and thermal barrier r , . ,fM ! i �t�C ,�rL.w❑Complies [FR23]1 installed per manufacturer's ❑Does Not � instructions. [I Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting '[]Does Not AAMA/WDMA/CSA 101/1.5.2/A440 , !❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches.Supply and I❑Not Observable 'return ducts in other portions of ❑Not Applicable .the building insulated>=R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR1513 ducts or plenums. ❑Does Not ,4 ❑Not Observable ❑Not Applicable j 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2. above 105 OF or chilled fluids ❑Does Not below 55 OF are insulated to aR- ❑Not Observable 3. --[]Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR2411 piping. []Does Not []Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to "R-_ R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 lHigh Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES - Page 5 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Additional Comments/Assumptions: 1 I High Impact(Tier 1) Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES - Page 6 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ❑Complies [IN13]1 or the installed R-values _ ❑Does Not ��. provided. -A Observable ❑Not Applicable j 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1f.of the ❑ Wood j❑ Wood Does Not ;table for values. 402.2.6 wall insulation on the wall ❑ Mass j❑ Mass ;❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel j❑Not Applicable 303.2 Wall insulation is installed per '❑Complies [IN411 manufacturer's instructions. ❑Does Not ;❑Not Observable "{❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 7 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ElWood E] Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel -❑Not Observable 402.2.6 [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not IFI211 Blown insulation marked every ❑ 300 ft'. Not Observable ; ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies (F122]2 'insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. '❑Not Observable ❑Not Applicable j 402.2.4 Attic access hatch and door R-_ R-_ ❑Complies [FI311 insulation aR-value of the ❑Does Not adjacent assembly. !❑Not Observable j ❑Not Applicable 402.4.1.2 -Blower door test @ 50 Pa. <=5 ACH 50 =_ l ACH 50 = ❑Complies [FI1711 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ;❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100cfm/100 :❑Complies [FI411 cfm/100 ft2 across the system or ft2 ft� :❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa.For rough-in tests,verification may need to j❑Not Applicable j occur during Framing Inspection. 403.3.2 Ducts are pressure tested to dm/100 cfm/100 ❑Complies [FI2711 determine air leakage with ft2 ftz ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable ,pressure differential of 0.1 inch ❑Not Applicable jw.g. across the system including j ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total j leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at <=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable j 403.1.1 Programmable thermostats ❑Complies [1`1912 !installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to ❑Not Applicable e I code specifications. pP 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not � . ❑Nat Observable ❑Not Applicable j 403.5.1 Circulating service hot water ❑Complies [FI1112 -systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ; ❑Not Applicable 1 I High Impact(Tier 1) _T2 IMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 8 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions Value Value & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed 3❑Does Not HVAC equipment meet efficacy and air Flow limits. .,❑Not Observable T❑Not Applicable j 403.2 Hot water boilers supplying heat ?[]Complies [F12612 through one-or two-pipe heating T❑Does Not systems have outdoor setback control to lower boiler water :❑Not Observable temperature based on outdoor ;❑Not Applicable j J temperature. 403.5,P Heated water circulation systems :. f❑Complies (FI2612 °'v,have a circulation pump.The []Does Not system return pipe is a dedicated return pipe or a cold water supply:.- ❑Not Observable j pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F1291' comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies (F13017 have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable 'supply pipe back to the heated water source through a cold - ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. __ 403.5.4 Drain water heat recovery units Y ❑Complies [FI3112 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. - Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable i 404,1.1 Fuel gas lighting systems have ❑Complies [F12313 no continuous pilot light. []Does Not ;fk, ❑Not Observable ❑Not Applicable ; 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES - Page 9 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _ 401.3 Compliance certificate posted. ❑Complies [1`1712 - ❑Does Not E]Not Observable _ ❑Not Applicable 303.3 :Manufacturer manuals for ❑Complies [FI1813 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable -!•i❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Medium Impact(Tier 2) 3 1 Low Impact(Tier3) Project Title: Cerrone Builders Inc Report date: 02/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1216 - DES- Page 10 of 10 Cerrone Lot 26 Devin Crt\1216 Rescheck.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments Manual S Compliance Re C EVIN p p U [� ALF 27,2017 Entire House :Ti OTTLANGWORTHY �!.4t? t .3 2091 P � c z 1 TOWN OF • • • For: CERRONE BUILDERS 70 DEVIN CT, QUEENSBURY, NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 10469 Btuh Entering coil DB: 75.2°F Outdoor design WB: 71.0°F Latent gain: 160 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 10628 Btuh Indoor RH: 50% Estimated airflow: 560 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCGD18S41S3+FC18A3XC1 Actual airflow: 583 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 36033 Btuh Entering coil DB: 68.2°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9V040A10MP11 Actual airflow: 583 cfm Output capacity: 38000 Btuh 105% of load Temp. rise: 50 °F 296.14-2-26 RC-000092-2017 Cerrone Builders 70 Devin Court 1424 s.f. SFD w/400 s.f. garage & gas FP Meets are all requirements of ACCA Manual S. 2017-Feb-27 10.41:22 wrightsoft• Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...cott.langewor by\DocumentslYork\70 DEVIN CT.rup Calc=MJ7 Front Door faces: N Residential Plans _ Review • Form ACCP.e RPER 1 • � ' • • . • • • 15 Mar 09 xcmrm.ecormsdm QUEENSBURY Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes No ❑ Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes No r-1 OEM performance data(heating,cooling,blower): Yes No ❑ Building plan#: DWG 2 Manual D Friction Rate Worksheet: Yes No M Duct distribution sketch: Yes No M Home address(Street or Lot#,Block,Subdivision): 70 DEVIN CT, Entire House HVAC • • ■ CALCULATION1 Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: _4 -F Orientation: Front Door faces North Indoor temperature: 70 ^F North,East,West,South,Northeast,Northweal,southeast,southwest Total heat loss: 36033 Btuh Number of bedrooms: 3 Conditioned floor area: 2849 fta Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 'F Windows Roe Grains difference: 27 gr/Ib @050% RH Eave overhang depth: 0 ft Sensible heat gain: 11632 Stun Internal shade: none Latent heat gain: 177 Btuh Blinds,drapes,etc. oepwindow Total heat gain: 11809 Btuh Number of skylights: 0 EQUIPMENTHVAC • 1 Heating Equipment Data Cooling Equipment Data Blower Data Equipment ty�1e: Gas furnace ETi�ment type: SplitAC Heating cfm: 583 umace,Hea pump,Boller,etc. tr onahloner,Heat pully,etc. Cooling cfm: 583 Model: York Model: York Staticpressure: 0 in H2O TM9V040A10MP11 TCGD18S4l S3+FC18A3XC1 Fan'sretetleste me l static pressure for Heating output capacity 38upd00 Btuh Total cooling capacity: 0 Btuh aaalen all/low xeatpampa-capacltyart lntaraesleno oorconaxions Sensible cooling capacity: 0 Btuh Aux heating output capacity: 0 Btuh Latent cooling capacity: 0 Stuh HVAC DUCT DISTRIBUTION SYSTEM ■ 1 Design airflow: 583 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: (1 m/100ft Branch duct: Sheet metal Fdctien Rale=ASP♦tTELI 1a3) declare the load calculation,equipment,equipment - - and duct design were rigorouslyperformed based on - building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality or Authority having jurisclictJon 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist +I+ wrightsoft' Right-Sufte®UniveMal20l7l7.0.16 RSU25116 Project Summa Job: 70 DEVIN 2017 Entire House Byt• SCOTFeb T LANGWORTHY Plan: DWG 2 Prooect Information For: CERRONE BUILDERS 70 DEVIN CT, QUEENSBURY, NY 12804 Notes: Design Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 74 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 33898 Btuh Structure 9981 Btuh Ducts 2135 Btuh Ducts 488 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36033 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipmer\t sensible load 9422 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Poor Fireplaces 1 (Poor) Structure 160 Btuh 0 Bu Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft' 2849 2849 Equipment latent load 160 Btuh Volume�ft.) 1044 1044 Air changges/hour 1.20 0.50 Equipment total load 9582 Btuh Equiv.AVF(cfm) 21 9 Req. total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade LATITUDE Model TM9V040A10MP11 Cord TCGD18S41S3 AHRI ref 4733111 Coil FC18A3XC1 AHRI ref 3739688 Efficiency 96AFUE Efficiency 11.0 EER, 13 SEER Heating Input 40000 Btuh Sensible cooling 12250 Btuh Heating output 38000 Btuh Latent cooling 5250 Btuh Temperature rise 59 OF Total cooling 17500 Btuh Actual air flow 583 cfm Actual air flow 583 cfm Air flow factor 0.016 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. G + wrlghtsoft• Right-suite®Universal 2017 17.0.16 RSU25116 2017-Feb-27 10:41 Page age I � ...cott.lengewanhy\Documents\York\70 DEVIN CT.rop Cale=MJ7 Front Door feces: N Right-J® Worksheet Job: 70 DEVIN Entire House Date: Feb 27,2017 B SCOTT LANGWORTHY Plan: DWG 2 MANUAL J:7th Ed. 1 Name of room Entire House Roomt Room2 Room3 2 Length of exposed wall 365.0 ft 1920 It 24.0 It 50.0 It 3 Raom dimensions 1.0 x 1450 ft 120 x 120 ft 1.0 x 658.0 ft 4 Ceilings 1 Condit.Option 9.0 ft I d 9.0 Ill heat/ood 9.0 ft beat/cocl 9.0 ft I heaVood TYPE OF CST HTM Arm Load(Btuh) Arm Load(Btuh) Area Load(Btuh) Area toad(Btuh) EXPOSURE NO. Htg Clg (ftp Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ftp Htg Clg 5 Gross a 16E0 6.4 0 3285 "'" •"' 1728 »•' ••.. 216 »» •"• 450 "" •»' Exposed b 0 0 !!!!!! '». •••• 111111 ••'• •••• Mill ••" •"' I!III! walls and C 0 0 HIM "" •••• 111111 — •••• 111111 "" •••• HIM •••• "" partitions d 0 0 !!!!!! "" "'" 111111 •••' •••• HIM "" `••• 11111! •••• »» e 0 0 !!!!!! •••• •••• 111111 «« «.. !11!11 •••• •••• 111111 «« ..., f 0 0 1111!1 "" ""' 111111 "" •""• 111111 "" ""•• 111111 •"`• •'•' 6 Windows and a 3D0 28.7 " 196 5236 "" 40 1069 "" 24 641 •». 60 1803 glass doors to 0 '• 0 0 "" 0 0 •"• 0 0 "" 0 0 "•• Heating C 0 0 0 """' 0 0 .... 0 0 •••• o0 »» d 0 " 0 0 •••• 0 0 "•• 0 0 •••• 0 0 e 0 " 0 0 "" 0 0 "" 0 0 "" 0 0 »•' f 0 "" 0 0 0 0 0 0 •""" 0 0 »" 7 Windows and North 17.0 60 •'•• 1020 0 '••• 0 24 •••• 408 12 •"' 204 glass doors NE/NW 0 0 •••• 0 0 '"" 0 0 •••• 0 0 "" 0 Coding E/W 620 88 •••• 5456 40 "" 2480 0 •••• 0 24 "" 1488 SE/SW 0 0 "" 0 0 •"' 0 0 •••• 0 0 "» 0 South 30.0 48 "" 1440 0 "'• 00 •••• 0 24 ... 720 Hoe 0 0 "" 0 0 "" 0 0 "" 0 0 ••"" 0 8 Other doors a 11E0 14.1 2e 105 1476 271 21 295 54 0 0 0 63 886 163 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 15E0 6.4 0 2984 19211 0 1887 10732 0 192 1236 0 327 2105 0 exposed to 0 0 111111 0 0 !1!1!! 0 0 111111 0 0 111111 0 0 walls and c 0 0 111111 0 0 !11!11 0 0 1111!1 0 0 11111 0 0 Partitions d 0 0 HIM 0 0111111 0 0 !111!1 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 !11111 0 0 111111 0 0 f 0 0 HIM 0 0 111111 0 0 !!1111 0 0 111111 0 0 10 Ceilings a 1630 2.4 1.1 1513 3695 1698 114 278 128 144 352 162 558 1363 625 to 0 0 1111!1 0 0 111111 0 0 111111 0 0 II!1!1 0 0 C 0 0 111111 0 0 111111 0 0 111111 0 0 1111!1 0 0 d 0 0 111111 0 0 111111 0 0 1!1111 0 0 1!11!! 0 0 G o 0 111111 0 o ItIII 0 0 HIM 0 0 1111!1 0 0 f 0 0 111111 0 0 111111 0 0 1111!1 0 0 111111 0 0 11 Floors a 21A0 1.8 0 1450 2675 0 1460 2575 0 0 0 0 0 0 0 (Note:room to 21A0 1.8 0 3 5 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 is displ. d 0 0 HIM 0 0 111111 0 0 HIM 0 0 1!!II! 0 0 for slab e 0 0 1!!111 0 0 !11111 0 0 I!l111 0 0 111111 0 0 Doors) f 0 0 !111!1 0 0 111111 0 0 HIM 0 0 111111 0 0 12 Inhitratlon 1 5.6 0.3 301 1700 96 61 344 19 24 136 8 123 695 39 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8.+11+12 •••, 33898 •••. •... 15294 «•• "»` 2364 ,«, •••• 8851 ••,, Less external heating •... 0 .... ••.. 0 •'•• ••« 0 "" ••« 0 •••, Less transfer •••• 0 •••• ,•« 0 '••' •«, 0 "" .... 0 •«• Heating redistribution •«• 0 •••• «•, 0 ••» •••, 0 «« .... 0 ..« 14 Duct lass 6% 2135 "" 6% 963 — 6% 149 «., 6% 419 "» 15 Total loss= 13+14 "`• 36033 "" — 16257 "•' "" 2513 "•' "'• 7070 "» 16 Ion.gains: People @ 300 0 •`•• 0 0 ••" 0 0 ••.. 0 0 "•• 0 Appl. C 1200 0 '••• 0 0 •"' 0 0 ••.. 0 0 "" 3240 17 Subtot RSH gain=7+8..+12+16 •••• •«• 9981 •••• •••, 2882 "" •••• 577 •••• •••• 0 Less external coding •••• ,«• 0 ••« •••, 0 — «« o •••• «•• 0 Less transfer •••• •«• 0 "`• •«, 0 «.' «« 0 ••« «» 0 Coding redistribution •••• .... 0 .... .... 0 «.. «« 0 ..« «.. 0 18 Duct gain 5% "' 488 5% •'» 131 5T. "' 28 5°A 158 19 Total RSH gain=(17+18)•PLF 1.00 "'•' 10469 1.00 •"' 2813 1.00 """ 605 1.00 "'• 3398 20 Air required(cfm) 583 583 283 157 41 34 114 189 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. Wrightsoft' Right-SuiteS Universal 2017 17.0.16 RSU25116 2017-Feb-27 10P.age 1 �.`N ...cotl.langeworthy\DxumentslYorkk7O DEVIN CT.mp Cax=MJ7 Front Door faces: N 9 Right-JO Worksheet Job: 70 DEVIN Entire House Date: Feb 27,2017 B : SCOTT LANGWORTHY Plan: DWG 2 MANUAL J:7th Ed TC4CeiIings sme0' Room4Room5 Roome Room?ength of exposed wall 26.0 ft 11.0 ft 0 ft 0 R oom dimensio12.0 x 14.0 ft 6.0 x 10.0 ft 6.0 x 10.0 ft 7.0 x 8.0 ft Condi.Option 9.0 ft heat/cool 9.0 ftj heal/cod 9.0 ftj heat/coal 9.0 It heat/cod TYPE OF CST HTM Area Load(Blah) Arm Load(Btuh) Arm Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ftp Htg Clg W) Htg CI; (ft2) Htg Clg (ftp Htg Cig 5 Gross a 15E0 6.4 0 234 •••• •••• 99 „'• •••• 0 •••• •,•• 0 •••• •,•, Exposed b 0 0 111111 '•" ••"• I!!!!! ""' "" 111111 "" •""* 111111 "" •"' walls and c 0 0 111111 •••• "•• Illlll `••' •••• 1111!! •••• •••• 111111 `•`• "'• partitions d 0 0 Mill "" "`• IIIIII ^" •••• !111!1 "" •«• 111111 "" "" e 0 0 111111 "" «» 111111 "" »" 111111 "^ "" 111111 "`• '•" f 0 0 111111 "" •"' 111111 "" "• IIIIII `^• 111111 "" '« 6 Windows and a 3D0 26.7 " 24 641 - 8 214 "'• 0 0 •"` 0 0 •"• glass doors b 0 " 0 0 •••• 0 0 "» 0 0 •••, 0 0 •••• Heating c 0 0 0 "'" 0 0 "' 0 0 ••• 0 0 d 0 0 0 "" 0 0 "" 0 0 ""' 0 0 e 0 ^ 0 0 0 0 0 0 '"" o 0 ^" 7 Wirxlo"and North 17.0 24 »» 408 0 •,,, 0 0 ,»' 0 0 - 0 glass doors NE/NW 0 0 "'• 0 0 •••• 0 0 •••• 0 0 - 0 Coding E/W 62.0 0 '•^ 0 8 »•• 496 0 •••• 0 0 ^" 0 SE/SW 0 0 "• 0 0 ""' 0 0 ••• 0 0 ^` 0 South 30.00 '•'• 0 0 ""' 0 0 •••• 0 0 «^ 0 H= 0 0 "" 0 0 `••` 0 0 '"" 0 0 •'•' 0 8 Other doors a 11E0 14.1 2.6 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 15EO 6.4 0 210 1352 0 91 586 0 0 0 00 0 0 exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 !11111 0 0 VIII! 0 0 111111 0 0 (!1111 0 0 Partitions d 0 0 IIIIII 0 0 001! 0 0 HIM 0 0 111111 0 0 e 0 0 111111 0 0 11111! 0 0 IIIIII 0 0 IIIIII 0 0 f 0 0 1!111! 0 0 1!1111 0 0 111111 0 0 !1111! 0 0 10 Ceilings a1630 2.4 1.1 168 410 188 60 147 67 60 147 67 58 137 63 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 !11111 0 0 IIIIII 0 0 111111 0 0 000 0 0 d 0 0 111111 0 0111111 0 0 111111 0 0 11111! 0 0 e 0 0 1111!1 0 0 111111 00 111111 0 0 11!11! 0 0 f 0 0 111111 0 0 !11111 0 0 111111 0 0 111111 0 0 11 Floors a 21A6 1.8 0 0 0 0 0 0 0 0 0 0 0 0 0 e:m (Notom b 21AO 1.8 0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 111111 0 0 111!!! 0 0 IIIIII 0 0 111111 0 0 is displ. d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 12 Infiltration 1 5.6 0.3 24 136 8 8 45 3 0 0 0 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 "" 2539 ,^` •••• 991 «" «» 147 "" "'• 137 ••" Less external beating ••» 0 "`• •••• 0 ,•,• «,• 0 •••• •,•• 0 •••• Less transfer '•" 0 »» •,•• 0 «•• ,,•• 0 •••• •••• 0 •••• Heating redistribution ,,,, 0 "•' ••,• 0 •••• •••• 0 •,« ••« 0 •••• 14 Duct loss 6% 180 «" "" 6% 9 "" 6% 9 15 Total loss=13+14 "•• 2699 ,,,, •••• 1054 •••• •••, 156 •••• •••• 145 •••• 16 Int.gains: People 300 0 '•'• 0 0 "'• 0 0 "" 0 0 - 0 Appl. @ 1200 0 "" 0 0 "" 0 0 "" 0 0 - 0 17 Subtot RSH gain=7+8.+12+16 •"' ••" 604 •••• `••' 566 '••• •••• 67 '••• - 63 Less external coding ••,, ••« 0 •••• ,•,• 0 •,,, •••• 0 "" - 0 Less transfer •," •••, 0 •••• »•• 0 •», •••• 0 •»• ^•, 0 Coding redistribution •,•• •••• 0 •••• •••• 0 •«, •••• 0 •••• ,,,• 0 18 Duct gain 5% »' 30 5% »• 28 5% ,• 3 5% 3 19 Total RSH gairF(17+18)'PLF 1.00 "" 634 1.00 ••" 594 1.00 "" 71 1.00 '""" 66 20 Air rerp red(cfm) 44 35 17 33 3 4 2 4 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. Wri htsOTt 2017-Feb-2710'.41.22 9 Righl-Sulte®Universal 201717.0.16 RSU25116 Page 2 ...cott.langeworthy\Documents\York\70DEVINCT.mp Calc=MJ7 Front Doorfaces: N Right-J® Worksheet Job: 70 DEVIN Entire House Date: Feb 27,2017 SCOTT LANGWORTHY Plan: DWG 2 MANUAL J:7th Ed. 1 Name of room RoomB Room9 Room10 Room11 2 Length of exposed wall 30.0 it 5.0 It 16.0 it 11.0 It 3 Room dimensions 13.0 x 120 it 13.0 x 5.0 It 120 x 4.0 it 7.0 x 120 ft 4 Ceilings I Condit.Option 9.0 it I heat/cod 9.0 ftl heaVcod 9.0 ftl heaUcod 9.0 it heat/cool TYPE OF CST HTM Area Load(Btuh) Area load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. I Htg I Clg (ft5 Htg I Clg (ft2) Htg I Clg (119 Htg I Clg (ft') Htg I CIg 5 Gross a 15E0 6.4 0 270 .... •••• 45 ••`• '•" 144 "" ""•" 99 "•• ••" Exposed b 0 0 IIIII "" •••` 111111 •"• "`• IIII!I "" "•"" !!III! "•` •"' walls and C 0 0 111111 '""' •••• 111111 •••• •«` IIIII •"' •••• !11111 •••• •«` partitions tl 0 0 111111 "'• •••• !!1!(I ... "" IIIII! "" "•• !!1111 "" «'• e 0 0 IIIII! •" »» till!! '""` "` !1!!!! 111111 " » f 0 0 111111 ""' 111111 "•• "' !I!!!! « "• 111111 »• 6 Wiabws and a 3D0 26.7 .. 24 641 •... 16 427 `»` 0 0 •••• 0 0 »•` glass doors b 0 — 0 0 ••.. 0 0 ,••, 0 0 •••• 0 0 «•• Heating c 0 » 0 0 •••• 0 0 "" 0 0 "" 0 0 •••• e 0 00 0 0 ` 0 0 ••• o o f 0 0 0 0 0 0 0 0 0 7 Windows and North 17.0 0 0 0 "•• 0 0 "'• 0 0 '••• 0 glass doors NE/NW 0 0 "" 0 0 "••• 0 0 "••• 0 0 •"• 0 Coding ENV 62.0 0 `•« 0 16 •.. 992 0 •'•• 0 0 ••`• 0 SE/SW 0 0 "" 0 0 "•' 0 0 •••• 0 0 ••"` 0 South 30.0 24 •»` 720 0 '••• 0 0 "" 0 0 »» 0 Hoz 0 0 0 0 •••• 0 0 •» 0 0 `•` 0 8 Other doors a 11E0 14.1 26 0 0 0 0 0 0 0 0 0 21 295 54 to 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 15E0 6.4 0 246 1584 0 29 187 0144 927 0 78 502 0 exposed b 0 0 !III!! 0 0 !!!11! 0 0 1111!1 0 0 1!!111 0 0 walls and C 0 0 !!!I!! 0 0 !!!11! 0 0 Mill 0 0 111111 0 0 partitions d 0 0 !11111 0 0 !!1111 0 0 111111 0 0 1!!111 0 0 e 0 0 111111 0 0 !!!III 0 0 111111 0 0 111111 0 0 f 0 0 IIMI 0 0 !!!!!1 0 0 111111 0 0 111111 0 0 10 Ceilings a 1600 2.4 1.1 156 381 175 65 159 73 48 117 54 84 205 94 to 0 0 !111!1 0 0 1!111! 0 0 IIIII! 0 0 Mill 0 0 C 0 0 111111 0 0 !!!!M 0 0 111111 0 0 11!!11 0 0 d 0 0 111111 0 0 1!1111 0 0 111111 0 0 111!11 0 0 e 0 0 111111 0 0 !11111 0 0 111111 0 0 !!1111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 !!!!I! 0 0 11 Floors a 21A0 1.8 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 21A0 1.8 0 0 0 0 0 0 0 0 0 0 3 5 0 Perimeter c 0 0 !!1111 0 0 1!!111 0 0 IIIII! 0 0 111111 0 0 is displ. d 0 0 800 0 0 1!111! 0 0 Mill 0 0 11101 0 0 for slab e 1 0 0 111111 0 0 1!1111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 !11111 0 0 111111 0 0 111111 0 0 12 Infiltration 1 1 5.6 0.3 24 136 8 16 90 5 0 0 0 21 119 7 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 ""« 2741 •••• •»` 863 .... •••' 1044 '•'• '•» 1126 Less external heating •••• 0 .... «•• 0 — •••• 0 ••« — 0 •••• Less transfer •••• 0 •••. ••.. 0 •••• •••. 0 •••• — 0 ••» Heating redisidbution •••• 0 •••. •••• 0 .... •••• 0 •,•• •.« 0 •'•• 14 Duct loss 6% " 173 """. 6% 54 • ' 6% 66 ."• 6% 71 "`• 15 Total loss=13+14 •••• 2914 "" .... 918 "'• .... 1110 '"« "•' 1197 '•" 16 Int.gains: People® 300 0 •`» 0 0 '•'• 0 0 `•" 0 0 '••` 0 Appl. @ 1200 0 ••" 0 0 '•'• 0 0 »" 0 0 »« 0 17 Subtol RSH gain=7+13-+12+16 "" ... 903 "" •"' 1070 .... "" 54 •"' "'• 155 Less external coding •••• «« 0 .«. ..« 0 •••• »« 0 •••• •••• 0 Less transfer •••• ••« 0 »» •'•` 0 •••• •»• 0 •••• •••• 0 Coding redistdbutim ."". •••• 0 "" ••.. 0 •••« •»• 0 •••• •••• 0 18 Duct gain 5% "» 44 5% •... 52 5% »» 3 5% "" 8 19 Total RSH gain=(17+18)"PLF 1.00 « 947 1.00 "'• 1122 1.00 `» 56 1.00 •" 163 20 Air requred(cfm) » 47 53 15 63 18 3 19 9 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. H'�rH wrightsof[• 2017-Feb-27 10:4122 Ae6lkRight-Suite®Universal 201717.0.16 RSU25116 Page 3 ...cott.langeworthy\Documents\YonVODEVINCT.mp Calc=MJ7 Front Dwrfaces: N 296.14-2-26 RC-000092-2017 Cerrone Builders S J I 70 Devin Court 1424 s.f. SFD w/400 s.f. garage & gas FP IE r '� a TO [J COMM N OF C,;=E?;: '`'URY tV , r u-VE. HENT 01 5-7 5� w � r 16` <-- PoRc k 55 F io CRKR d s � - � i - MAP REFERENCE: THE VILLAGE AT SWEET ROAD 1 MAP OF A SUBDIVISION PLAN . MADE FOR CERRONE BUILDERS DATED: FEBRUARY 5, 2014 LAST REVISED: JULY 30,. 2014 BY: VAN DUSEN & STEVES FILED: SEPTEMBER 30, 2014 LOT 25 5qq 3 N 62°16'451 E H.O.A. '135.001 _ CO" ELE Pte' LOT 20 i wf;cx i MN AREA �_ o i 1 0,.41328 ARES T 35.J' ` o� - _ ' o a �F 5,9' G j F1SFrIFlLI-G,`\,VE - O O = l 1�Q O d h r•. n! I" SEWF�C C.O. 1 T 3 0 LOT 27 N'l 'r� NOTES: `i c.s���� 1. PARCEL MAY BE SUBJECT TO AND OR BENEFIT FROM RIGHTS, 1t EASEMENTS, COVENANTS, AND RESTRICTIONS INCLUDING: t "' . I. ]. AN EASEMENT GRANTED TO NIAGARA MOHAWK POWER s tfs ' �1 ij , CORPORATION & VERIZON NEW YORK INC. RECORDED IN THE WARREN COUNTY CLERK'S OFFICE IN BOOK 5120 OF DEEDS, <Ci • �J AT PAGE 10. 5013 ® ( / 1.2. DECLARATION OF COVENANTS, RESTRICTIONS, EASEMENTS „.tom,..... ...... ._ . AND LIENS OF THE VILLAGE AT SWEET ROAD HOMEOWNERS' _ LA'N ASSOCIATION, INC. RECORDED IN THE WARREN COUNTY W Y- � y s•. _._._ /,�y ! J( � �"� CLERK'S OFFICE IN BOOK 5175 OF DEEDS, AT PAGE 148. j� {� o i`1 ✓/' g� 1.3. RIGHT-OF-WAY AND EASEMENT TO THE TOWN OF QUEENSBURY - -- 1 � FOR SEWER RECORDED IN THE WARREN COUNTY CLERK'SF I 'N'AL U RVEY OFFICE IN BOOK 5167 OF DEEDS, AT PAGE 248. 1 t ,°....._......... To91°1I1 �)F g 1 a g,1S 1� DATED: AUGUST 4, 2017 �' 11i�d11JiVd`' i3At/11. 1 Datel August 4, 2017 "-T �I�II�p$��7j �.,w_... -.-.-.._.... Map of a Survey for � C \b \\l -�°�-�' u s '7/�.,,,, 'UNAUTHORIZED ALTERATION UR ADDITION TO A SURVEY S- I c a�e 1'=30' .�•-.lam- /// �I MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A - �� - _ •--•-••-• �I "u/6J/. VIOLATION OF SECDON 7209,SUE3_UiASION 2,OF THE J Steven ,/�y'�y®'/7�y-�-'p^ qy� 'pg® ®/'7�, (meq U(, NEW YORK STATE EDUCATION LAW.' e✓ ® `S_/8 9 A c A.J - q°'�'� ho 'ONL'f COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF LAND SURVEYORS '®+.../ - SEAL SHALL DE CONSIDERED TO UE SID TRUE COPIES.” - . "CERT FICA DE IBONS INDICATED HEREON SIGtllFY THATAnd ITIIS SURVEY WAS PREPARED IN ACCORDANIE WITH THE - ^gF' E%IS1IE CODE OF PRACTICE FOR llQN SURVEYORS ADOPTED - ..19¢I+�.S. BY Tt!E NEW 1GRK STATE AS50(IA TION OF PROFESSIOfIAL LA 4D SURVEYORS.SAID OM TIH 5URVE SHALL RUN ONLY m TO IHS PERSON FOR WHOM THE MPANE'Y IS PREPARED,ANDijorothy Ungerer SHEET 9 OF q ON HIS BEHALF TO THE RILE CGI,II'ANY,GOVERNMENTAL 6C771T�7 ! 1 0J 1 (' [[y y .8 Road g, T�,� `(/ )[y/� AGENCY AND LENDING INSTITUINGIl USTED HEREON,AND 169 11av11a d Road Queensbury, New w l ork 12804 TO THE ASSIGNEES GF THE LEfirltIG'It6THUTION." Town of Queer�sbury, WarrenCoux�i:y, New York(51 ) '792-84'74 New `York Lic. No. 50135 NO. DATE DESCRIPTION DWG. NO. 05-247-LOT 26 L - �. . 296. 14-2-26 hug, G7• GVII J• VUnvl Iviv.n IVU. V79L r• L/ C) MII�DL� I�EI'AI2TMLNT INSPECTION AGENCY, INC. �e�r'zd`cQ;that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Cerone Date. 08/11/2017 Occupant- Same Location- Devin Ct Occupancy'Single Family Dwg. Queensbury, Warren Co. NY Applicant- � Cerrone Builders Gianni Cerrone 1589 Rt 9 Fort Edward, NY 1 2828 J Joseph A.Holmes . No 1453141357311 T.L Equipment: 200 -Amp. Service Equipment; 4/0 -Service Conductor; 34 Switches; 44 - Receptacles, 39 -fixtures; 1 - Sumer, Wiring & Control; 1 - 30 Amp Receptacle; 2 -Vent Fans, 6 -Smoke Detectors; 10 -Arc Fault Breakers >, This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the aoove noted nate Dased on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,Effi- of the property indicated above, lhfs cerifflcate shall be Immediately null and void. ciency or fitness of the equipment for any particular purpose, This certificate shall In the event that this certificate becomes invalid based upon the above conditions. be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An appllcatlon for inspection must be submitted to Middle ed to.the introduction of additional electrical equipment and/or the replaco-ment of Department inspection Agency, Inc. to Initiate the inspection and revatidetien any of the components installed as of the above noted We,this certificate shall be process. A fee wilt be charged for this Service. I �� f AUG 3 0 2017 1 1 T OWN uF dQDEE.NSSURY BUILDINGS& Cor;rS