RC-00012-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000123-2017 Date Issued: Monday, July 24, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000123-2017 has been completed. Tax Map Number: 295.10-1-6 Location: 2 Hillside DR Owner: Patten Property Development Applicant: Patten Property Development This structure may be occupied as a: Single-Family Dwelling 1,423 sq. ft. 420 sq. ft.att.garage By Order of Town Board Subdivision: Stonecroft,Section I TOWN OFQUEENSS�BURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, ` G•yt'jxT/ �d Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000123-2017 Tax Map No: 295.10-1-6 Permission is hereby granted to: Patten Property Development For properly located at: 2 Hillside DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Patten Property Development Single Family-New $150,000.00 Owner Address: 20 Ridgewood CT Total Value $150,000.00 Queensbury,NY 12804 Contractor or Builders Name/Address Electrical Inspection Agency Patten Property Development 20 Ridgewood CT Queensbury,NY 12804 Plans&Specifications Single-Family Dwelling 1,423 sq.ft. 420 sq.ft.aft.garage Subdivision: Stonecroft,Section 1 $347.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,April 11,2018 (If a longer period is required,an application for an extension must he made to the code Enforcement Officer of the Town of Queensbury before the a ratiioo�n dakdri]71,2017 Dated at the Town o Queens /-J Tu SIGNED BY: V for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only Permit#: /��� /23 �C) 7 PRINCIPLE STRUCTURE PERMIT Permit Fee: $ 3`(7 6, APPLICATION An.n N(Linnebus 742 Bay Road,Queensbury,NY 12804 Rec Fee:$,1—v i _: , �_ �•�Yc P:518-761-8256 www.ciueensbury.net Invoice#: Project Location: 7— )YI&IJP �A) 4� Tax Map ID #: 2_17 S, l(}/ —(p Subdivision Name: >i >i c✓ -- � 'C 'TOWN BD. RESOLUTION 86-2013: $850 recreation fee for new dwelling e9ftfarIMI -family, multiple family, apartments, condominiums,townhouses, and/or manufactu e t bile homes. This Is In addition to the permit feels). MAR 2 9 2017 CONTACT INFORMATION: TOWN OF QUEENSBURY • Applicant: COMMUNITY DEVELOPMENT /� Name(s): C(i Ly P-r—geyA Mailing Address, �}S/Z: 2p Rt�t Cell Phone: �� )ma y& yG,Sy Land Line: � ) Email:_Tm kv( 9�Y P c n� ,/, ca, Primary Owner(s): a Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: • Contractor(s): Business Name: S/9/LrF a�le.1 Pte' ! Dt.eW0_� Contact Name(s): Mailing Address, C/S/Z: Cell Phone: _�) Land Line: � ) Email: • Architect(s)/Ensineer(s): Business Name: _ Wlllfh.;,r oL,,d Contact Name(s): `D a Mailing Address, C/S/Z: &tt+ Cell Phone: �_) 79k-y 6s-7 Land Line: �) Email: Contact Person for Building & Code Compliance: C I/ tf'S Cell Phone: 71( Land Line: � ) Email: Town of Queensbury Building&Code Enforcement Principle Structure Apphution Re sed February 2017 PROJECT INFORMATION: y TYPE: Commercial 'id- ,al WORK CLASS: Single-Family —Two-Family Multi-Family(#of ) Townhouse Business Office Retail Hotel/Motel —Industrial/Warehouse ._Garage(#of cars _ Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUAREE FOOTAGE: I"floor: /7 96 Is'floor: ) 2"d floor: IU L7 2"d Floor: 3`d floor: Total square feet: L12D 4"floor: Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ bir 2. Proposed use of the building: Sr h i L<, �-a IN 3. If Commercial or Industrial, indicate the name of the business: �- 4. Source of Heat (circle one) as Oil Propane Solar Other: (Fireplaces need a separate as Burning Appliances & Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES' 03Explain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? /Zo X 20 9 b. Is this a corner lot? YES NO c. Will the grade be change as a result of the construction? YES 1�0� d. What is the water source? PUBLICRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system -- < S DECLARATION: I . I acknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. -i. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor ofall newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 041-13 ✓13 " SIGNATURE: ce� �iZ � DATE: 7.312-1117 Tmm� R rndn Fnfmromnnr Prinrinlr Strurlurn Annhrallnn Revised February 2017 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 /�� � Imm.J(Znrn.Mn• P;518-761-8256 www.gueensbury.net Permit#: 0 17 Tax Map ID#: 2q 51 AH —6-01 Permit Fee:$ ; Invoice#: Project Location: `)t 11.f (dr D�p yr Septic variance? Yes No Primary Owner(s) Ch lis Mailing Address 20 A 4- u,o• C. Phone & Email —7,7G 416 �'- r�Ir Installer/Builder 001 I Nn Mailing Address111111 Phone& EmailT yG Engineer ✓�o KW4'tis TOWN OF QUEFNSAI Jay Mailing Address Z oJr� t ��� LOPMENT Phone& Email l yy 3 p 11 Contact Person for Building&Code Compliance: CV-if Qayy Phone: 27G°/loSz/ RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Ye 1980 or older Installed? (circle one) Spa or Hot Tub Yes N 1981-1991 Installed? (circle one) 1992-Present 3 / / 0 3 O PARCEL INFORMATION: Topography _Flat Rolling _Steep Slope _%Slope Soil Nature Sand _Loam _Clay _Other Groundwater At what depth? .Vxo, C /Z Bedrock/Impervious material At what depth? Domestic Water Supply _Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate:Z:S I per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size Bob gallons(min. size 1,000 gallons,add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with #2 stone Total length ft.; Each Trench ft. Seepage Pit with#3 stone How many: Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size #of tanks NOTES:1.Alarm system &associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. n PRINT NAME: DATE: SIGNATURE: �/l�i� /i " DATE: Town of Queensbury Building&code Enforcement Revised February 2017 +�+ wrightsoft Load Short Form D EC E OWE to: 2H is81 ZOD�ve,Queens ... Entire HouseAnthony Averse WeBRePS LLC. MAR 2 9 2017 I -n: 2 Hillside Drive 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800 810.3280 Fax:888 971-299APIA Pp U ENSB RY brepsvnolesale.com License: ... Project • • For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Design • • Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db (°F) 70 75 Construction quality Semi-tight Design TD (°F) 74 10 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/Ib) 29 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GMSS920603BN Cond GSX130301B AHRI ref 7367472 Coil CAPT3743A4A AHRI ref 5611306 Efficiency 92.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input 60000 Btuh Sensible cooling 19740 Btuh Heating output 55000 Btuh Latent cooling 8460 Btuh Temperature rise 54 OF Total cooling 28200 Btuh Actual air flow 940 cfm Actual air flow 940 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.055 cfmlBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Stairs 43 0 0 0 0 Dining Rm 98 1358 3251 47 180 Kitchen 191 2145 2380 75 132 Lndry 28 750 276 26 15 Entry 21 0 0 0 0 Great Room 415 6917 4177 241 232 Bdrm# 3 100 2673 1675 93 93 Cl 3 16 0 0 0 0 Ln 8 0 0 0 0 Bath 56 1075 180 38 10 Hallwy 40 0 0 0 0 Up Stirs 36 0 0 0 0 Cl 2 12 0 0 0 0 Bdrm# 2 125 2809 1750 98 97 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrightsoft' Right-Suite®Unhersal 2017 17.0Page.19 RS000902 2017-Mar-28 10:age I 1 o411CCK ...elopment, 2 Hillside Drive,Queensbury,Wimp Calc=W8 Front Door faces: E Mstr Bath 52 1216 185 42 10 WIC 24 0 0 0 0 Master Bdrm 161 2629 2227 92 123 Basement 752 5362 861 187 48 Bsmnt Strs 43 0 0 0 0 Entire House 2220 26933 16960 940 940 Other equip loads 12346 2756 Equip. @ 1.00 RSM 19717 Latent cooling 6187 TOTALS 2220 39279 25904 940 940 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Mar-28 10:20:53 r.� W right5Oft' Rot-Suites Universal 2017 17.0.19 RSU00902 Page 2 ACM ...ebgnent, 2 Hillside Droe,Queensbury,NY wp Calc=M18 FmM Door faces: E Component Constructions Job: 2Hillside Drive,Queens ... wrightsoft Date: Mar 28,2017 Entire House By: Anthony Averse WeBRePS LLC. Plan: 2 Hillside Drive 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800 810.3280 Fax 888 971-2999 Email:manualj@mbrepshvaacom Web:w,wt.xebrepswbolesale.com License:... Project • • For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Design-Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 29.4 26.5 Dry bulb (°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insult R Htg HTM Loss Clg HTM Gain n' BIWII'T W.-FISH SWM' BM SWM* Stun Walls 12F-Osw:Frm wall,wd ext,r-21 cav ins,1/2"gypsum board int fnsh, n 384 0.065 21.0 4.78 1835 0.61 235 2"x6"wood frm,16"o.c.stud a 186 0.065 21.0 4.78 891 0.61 114 s 454 0.065 21.0 4.78 2167 0.61 277 w 343 0.065 21.0 4.78 1641 0.61 210 all 1367 0.065 21.0 4.78 6533 0.61 835 15B13.Owc-8:Bg wall,heavy damp soil,2"x4"wood int firm,concrete n 214 0.049 13.0 3.60 771 0 0 wall,r-13 cav ins,10"ink,1/2"gypsum board int finish a 300 0.049 13.0 3.70 1109 0.01 4 s 186 0.049 13.0 3.11 579 0 0 w 278 0.049 13.0 3.46 962 0 0 all 978 0.049 13.0 3.50 3422 0.00 4 Partitions 12F-Osw:Frm wall,3/8"wood shin,r-21 cav ins,1/2"gypsum board int 312 0.065 21.0 4.78 1491 0.13 41 fish,2"x6"wood frm, 16"o.c.stud Windows 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk: n 18 0.250 0 18.4 331 8.39 151 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk; a 79 0.250 0 18.4 1455 31.5 2496 6.67 ft head ht s 26 0.250 0 18.4 485 16.4 433 s 28 0.250 0 18.4 515 16.4 459 w 62 0.250 0 18.4 1136 31.5 1948 w 12 0.250 0 18.4 221 31.5 378 all 225 0.250 0 18.4 4142 26.0 5865 4A5-2ovd:2 glazing,clr low-e outr,air gas,vnl firm mat,clr innr,1/4" w 41 0.300 0 22.1 900 32.0 1306 gap, 1/4"thk;NFRC rated(SHGC=0.31);6.67 it head ht Doom 11 DO:Door,wd sc type a 20 0.390 0 28.7 585 8.03 164 Ceilings 16B-38ad:Attic ceiling,asphalt shingles roof mat,r-38 ceil ins,1/2" 1089 0.026 38.0 1.91 2081 1.15 1248 gypsum board int fish 2017-Mar-28 10:20:53 ti wr'ightSOft' Right-Sufte®Universal 2017 17.0.19 RSU00902 Page 1 a41M ...elopmem, 2 Hillside Drive,Queensbury.NYmp Calc=MJ8 Front Door faces: E Floors, 19C-19cscp:Fir floor,firm fir,6'lhkns,carpet fir fnsh,r-2 ext ins,r-19 293 0.049 30.0 1.25 366 0.17 50 cav ins,light crwl ovr,r-11 wall insul 21A-32t:Bg floor,heavy damp soil,8'depth,carp 80%fir fnsh 795 0.020 0 1.47 1168 0 0 2017-Mer-28 10:20:53 ACS` ...ebpWPIghtSOft" Right-Suae®unhv ai 201717.0.19 Rsu0090z Page 2 menl, 2 Hillside Drive,Queensbury NY.rup Cab=WB Front Door faces: E Project Summar Job: 2 Hillside Drive,Queens... wrightsoft y Date: Mar28,2017 Entire House By: Anthony Averse WeBRePS LLC. Plan. 2Hillside Drive 1880 82nd Avenue Suite M 203,Vero Beach,FL 32966 Phone:800 810-3280 Fav:888 971-2999 Email:manualj@mbmpshvac.com Mb:x .vebrepswholesale.com License:... Prouect Information For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Notes: 2 Hillside Drive, Queensbury, NY Design • • Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 74 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26933 Btuh Structure 16960 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(97 cfm) 7716 Btuh Central vent (97 cfm) 1050 Btuh Outside air Outside air Humidification 4630 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 39279 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19717 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 4460 Btuh Ducts 7 Btuh Central vent (97 cfm) 1720 Btuh Heating Cooling Outside air Area (ft') 2220 2220 Equipment latent load 6187 Btuh Volume (W) 11445 11445 Air changes/hour 0.41 0.15 Equipment total load 25904 Btuh Equiv.AVF (cfm) 78 29 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GMSS920603BN Cond GSX130301B AHRI ref 7367472 Coil CAPT3743A4A AHRI ref 5611306 Efficiency 92.1 AFUE Efficiency 11.0 EER, 13 SEER Heating Input 60000 Btuh Sensible cooling 19740 Btuh Heating output 55000 Btuh Latent cooling 8460 Btuh Temperature rise 54 OF Total cooling 28200 Btuh Actual air flow 940 cfm Actual air flow 940 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrl ht50f[' 2017-Mar-2810:20:53 G�c. 9 Righl-Sutle®Universa12017 17.0.19 RS000902 Page 1 iR.�.n ...elopmenl, 2 Hillside Drive,Queensbury,NY.rup Calc=MJB Front Door faces: E Manual S CRJob: 2Hillside Drive,Queens ... +�+ Wrightsoft Compliance Date: Mar 28,2017 Entire House By: Anthony Averse WeBRePS L.L.C. Plan: 2Hillside Drive 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800 810-3280 Fax:888 971-2999 Email:manualj@mbrepshwc.com Web:w webrepsvholesale.com License:... ProjectMENEM • • For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 19717 Btuh Entering coil DB: 77.8°F Outdoor design WB: 70.8°F Latent gain: 6187 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 25904 Btuh Indoor RH: 50% Estimated airflow: 940 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: Split AC Manufacturer: Goodman Mfg. Model: GSX130301 B+CAPT3743A4A Actual airflow: 940 cfm Sensible capacity: 19740 Btuh 100% of load Latent capacity: 8460 Btuh 137% of load Total capacity: 28200 Btuh 109%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 39279 Btuh Entering coil DB: 62.3°F Indoor design DB: 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Gas furnace Manufacturer: Goodman Mfg. Model: GMSS920603BN Actual airflow: 940 cfm Output capacity: 55000 Btuh 140%of load Temp. rise: 50 OF Meets are all requirements ofACCA Manual S. 2017-Mar-28 10:20:53 WrightSOtt' Right-Suite®Universal 2017 17.0.19 RS000902 Page 1 ACCa ...elopment, 2 Hillside Drive,Queensbury,NY.rup Calc=W8 Front Door faces: E CID( Generated by REScheck-Web Software Compliance Certificate Project 2 HILLSIDE DRIVE, QUEENSBURY rr�� ((� n Energy Code: 2015 IECC D E `v' E III E D Location: Warren County, New York Construction Type: Single-family Fk7� 22 2r.•: Project Type: New Construction Orientation: Bldg. faces 90 deg. from North Conditioned Floor Area: 14% TOWN OF QUEENSBURY Glazing Area 14% ft2 COMMUNITY DEVELOPMENT Climate Zone: 6 (8499 HDD) Permit Date: 295.10-1-6 RC 123-2017 Permit Number: Chris Paffen Construction Site: Owner/Agent: 2 Hillside Drive Stonecroff, Sec. 1 2 HILLSIDE DRIVE SFD w/ aft. garage QUEENSBURY, New York 12804 Compliance:Passes using UA trade-off Compliance: 0.8%Better Than Code Maximum UA: 258 Your UA: 256 The%Better or Worse Than Code Inde.reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont U-Factor UA Assembly or R-Value R-Value Perimeter Ceiling: Raised or Energy Truss 1,118 38.0 0.0 0.025 28 Floor: All-Wood joist/Truss Over Uncond. Space 310 30.0 0.0 0.033 10 Wall:Wood Frame, 16in. D.C. 291 21.0 0.0 0.057 13 Orientation: Front Window: Vinyl Frame, 2 Pane w/Low-E 31 0.250 8 Orientation: Front Door: Solid 40 0.140 6 Orientation: Front Wall:Wood Frame, 16in. D.C. 219 21.0 0.0 0.057 12 Orientation: Right side Window: Vinyl Frame, 2 Pane w/Low-E 6 0.250 2 Orientation: Right side Wall: Wood Frame, 16in. D.C. 291 21.0 0.0 0.057 12 Orientation: Back Window: Vinyl Frame, 2 Pane w/Low-E 40 0.250 10 Orientation: Back Door: Glass 40 0.300 12 Orientation: Back Wall: Wood Frame, 16in. D.C. 219 21.0 0.0 0.057 11 Orientation: Left side Window: Vinyl Frame, 2 Pane w/Low-E 31 0.250 8 Orientation: Left side Wall: Wood Frame, 16in. D.C. 162 21.0 0.0 0.057 6 Orientation: Front Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 1 of10 Gross Area Cavity Cont. U-Factor UA Assembly or R-Value Window:Vinyl Frame, 2 Pane w/Low-E 61 0.250 15 Orientation: Front Wall:Wood Frame, 161n. o.c. 275 21.0 0.0 0.057 15 Orientation: Right side Window: Vinyl Frame, 2 Pane w/Low-E 12 0.250 3 Orientation: Right side Wall:Wood Frame, 161n, o.c. 162 21.0 0.0 0.057 7 Orientation: Back Window:Vinyl Frame, 2 Pane w/Low-E 31 0.250 8 Orientation: Back Wall:Wood Frame, 16in. o.c. 275 21.0 0.0 0.057 16 Orientation: Left side Basement:Solid Concrete or Masonry 276 0.0 13.0 0.051 14 Orientation: Front Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement:Solid Concrete or Masonry 208 0.0 13.0 0.051 11 Orientation: Right side Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement: Solid Concrete or Masonry 276 0.0 13.0 0.051 13 Orientation: Back Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Window:Vinyl Frame,2 Pane w/Low-E 16 0.290 5 Orientation: Back Basement:Solid Concrete or Masonry 208 0.0 13.0 0.051 11 Orientation: Left side Wall height:8.0' Depth below grade: 7.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Lynn Delurey- Designer .L D +y 3/22/17 Name-Title Sign re Date Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 2 of 10 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PRI]' energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7energy code compliance for ❑Not Observable j [PR3]1 ;lighting and mechanical systems. g, !Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC j Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr_ ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Ak Manual J or other methods Btu/hr Btu/hr ❑Not A licable approved by the code official. PP Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 3 of 10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions .I & Re D _ 402.1.1 Conditioned basement wall R- R-_ ❑Complies See the Envelope Assemblies (FO4]1 insulation R-value.Where Interior R- R- ❑Does Not table for values. V, insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not - ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not 0 manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall _ft _ft ❑Complies See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. []Not Observable ❑Not Applicable 303.2.1 A protective covering is Installed - ❑Complies [FO11]2 .to protect exposed exterior - ❑Does Not insulation and extends a j minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 1,Snow-and ice-melting system ❑Complies [FO12]2 :controls Installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 4 of 10 Sec#on Framing / Rough-In Inspection Plans Verified j Field Verified Complies? Comments/Assumptions & Re .ID Value Value 402.1.1, Door U-factor. U- U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 j❑Not Observable ❑Not Applicable 402.1.1, (Glazing U-factor(area-weighted U-_ U-_ ;❑complies See the Envelope Assemblies 402.3.1, laverage). 0Does Not table for values. 402.3.3, 402.3.6, j❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ;;❑Complies [FR4]1 !are determined in accordance ,[]Does Not with the NFRC test procedure or •� ;taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 (Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not ® instructions. �t❑Not Observable j .,❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting -[]Does Not AAMA MDMA/CSA 101A.S.21A440 -.!,[]Not Observable j or has Infiltration rates per NFRC ❑Not Applicable 400 that do not exceed code PP limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/Interior finish ❑Does Not and labeled to indicate s2.0 cfm "M& leakage at 75 Pa. []Not Observable []Not Applicable 403.2.1 Supply and return ducts in attics ❑complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where< 3 inches. Supply and []Not Observable return ducts in other portions of - - -" --- -- ❑Nat Applicable the building insulated>= R-6 for diameter>= 3 inches and R-4.2 .. ... .-_ for< 3 Inches in diameter. 403.3.3.5 Building cavities are not used as ',❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable j ❑Not Applicable 403.4 HVAC piping conveying fluids R R- ❑Complies [FR17]2 I above 105 QF or chilled fluids ❑Does Not !below 55 QF are insulated to aR- [-]Not Observable j '3• ❑Not Applicable 403.4.1 1 Protection of insulation on HVAC ❑Complies [FR24]1 ;piping. ❑Does Not 10 ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R ❑Complies [FR18]2 >_R-3. ❑Does Not []Not Observable j ❑Not Applicable 403.6 Automatic or gravity dampers are - ❑Complies [FR19]2 installed on all outdoor air I ❑Does Not intakes and exhausts. -' ❑Not Observable r. j ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 5 of 10 Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & RegAD 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not vi provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R-_ ❑Complies See the Envelope assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel ❑Not Observable 0 ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN211 in substantial contact with the underside of the subfloor, or floor []Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing _members. 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least'/.of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [-]Not Observable [IN3]1 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 ;Wall insulation is installed per ❑Complies [IN4]1 1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies. Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R-_ ; complies See the Envelope Assemblies 402.2.1, E] Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable ,402.2.6 ❑ [Fill, Applicable FIl] 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's Instructions. ❑Does Not [FI211 Blown insulation marked every ❑ 300 ft2. Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI2212 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 Attic access hatch and door R- R-_ ❑Complies [F13]1 insulation a:R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 = ❑Complies [F11711 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 ;Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F1411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air j handler @ 25 Pa. For rough-in ❑Not Observable ;tests,verification may need to ❑Not Applicable .occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [1`12711 determine air leakage with ft2 ftz ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air - handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of El Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ._ ... ❑Complies [1`19]2 installed for control of primary []Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [Fl 10]2 on heat pumps. []Does Not ❑Not Observable ■III ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [1`911]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) .2: Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID _ 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 (fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ;❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hat water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy Input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104QF. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side []Not Observable pressure loss of drain water heat ❑Not Applicable recovery units < 3 psi for pp individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not -fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .iD 401.3 Compliance certificate posted. ❑Complies [FI712 ❑Does Not ❑Not Observable ❑Not Applicable _ 303.3 Manufacturer manuals for ❑Complies [FI1813 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2 HILLSIDE DRIVE, QUEENSBURY Report date: 03/22/17 Data filename: Page 10 of10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.25 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments II Af"NOTES I I I Lands Now or Formerly of 1, Boundaryinformation shown hereon perMap Reference 1. Lawrence E. Bill & Debora L. Bill 2. North onentationandbearmgbaseperMapReference I II I Book 1075 Page 7 3. Wallen County taxparcel2991 T-6. ,295.1-1-7 I I 4. the location of underground improvements or encroachments,ifany exist,oras shown hereon,are not certified. There maybe other underground utilities,the existence of which are unknown. Size and location of all underground utilities must be verified by the appropriate authorities The Underground Facilities 5891200'E Protective Organization must be notified prior to conducting test borings,excavation and construction. ---- '– 164.545. This survey was prepared without the benefit ofan up to date abstract of title. r 101Setback — —— — 6. Reproduction or copying of this documentmay be a violation ofcopyrightlaw unless permission of the 44.3' authorand/orcopyrightholderisobtained. I 7. A copy of this document without a proper application of the surveyors embossed seal should be assumed to be an unauthorized copy. � AREA 31,189f sg,ft, I (corrected) s, ' 8. Setbacks shown perMap Reference 1. I Proposed I I ProposeProposed Residence Driveway Septic Tank I I ZT 6 ' 37.0' � � MMOPMENT I Proposed SEPTI Pporch a � I HAVE SEEN OR OBSERVED ALLOBJECTS Lands Now or Formerly of Pro osed °� � ~ SUCHAS SES, WELLS, TREES, FENCES, ETC P SHO ON T IS DOCUMENT.I HAVE PERSONALLY Thomas D. Chase Leach FieldBook 696 Poge 777 RY MEAS RE E DISTANCE SET FORTH ON T D M' ENT ,295.1-1-5 I SIGNATURE DATE I II Length of these lines adjusted to yield a proper closure while DEEDREFERENM I maintaiaingspecified curve I geometryperMap Reference Z 1. Conveyance to Roger W.Farr by deed dated june27,2013,filed in the Waren County Clerks Office on I I July l7,2013 in Book 4808 ofDeeds atpage 110. 30'Setback— — — I MAPREFERENCE,- 20'Wide Drainage Easement r 1 (per Map Reference 1) 20.00' 1 Map entitled'Map ofStonecrofta Subdivision made for Kenneth E.Mahosla prepared by Van Dusen,and Steves,dated March 25,1983,filed in the Waren County Clerks Office on August22,1983 as map number SV'36'30"W A-76. J 121.03' / (corrected) i 5 f L-3428 295.10-1-6 RC 123-2017 R=25 00 Ch48�1930"W,31.66 Chris Patten _ — — — — WESTMOUNTAINROAD 2 Hillside Drive (Stonecroft, Sec. 1) SFD w/ aft. garage = - "'`°M ME REVISKM REMM/DE5CRFnmDRAHERm ne DOMMW�^�'�e rn� Map of Proposed PlotPlan MOLMEN OF s � Lands to 1e Conveyed to SUM EMXMM 0 20+7 Patten Property Development, LLC 0-M L.W S...,`,o,PLLC APPROVE6.IGND TOWWOFQUEENSBURY WARRE7VC0UN7`Y,NEWY0RK DRAF7ZV..•REB M Darrah Land Surveying PLLC 17020-1 PROD NO. 17020 3764North Shore Road,Hadley,New York 12835 Phone 1•r BOUNM n�MAPS wnH�SURVEMrS°M0� . 518 1691 s11EE7 IOFZ gx ME GDA"TME un cawRior COPEa OF THE 9UNVEMn SCALE:1WO' ( J 79B oww+u wows MM OPRMC DATE:03/20/2017 PROJNQ 17020 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road—Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit NoAX -.123L.20 1I...Ce t- N o 44931 Cut-in Card No..................................... Owner..........e.Z.....1....04.-. EV....... ............................................................ ..................... ...................t.,./...................................2..........I............................... ................ .................... Installation Consisting of 2 .(.... Z. :✓f?�f..GI. ..[a9 �T :.................._ ....,e .......................................................................................................... .................................................................................................................................................................................... InstalledBy............S. .6..................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspector's of this Company shall have the privilege of making i ections at any time, and if its rules are violated,the Company shall have the right to rev this ce i ate. Date..... .... .. .. .......... INSPECTOR........................ . .... .......................... Member N.F.P.A.,I.A.E.1. I I MAPNOTES II I Lands Now or Formerly of L Boundaryinformadonshown hereonperMapRe&rencel.Improvementsshownheronperfielddata I Lawrence E. Fill & Debora L. Bill captured on Aprd 0.3,2017 II Book 1075 Page 6 I 2. North onentation and bearing base perMap Reference L II 295.10-1-7 I 3. Waren County tax parce1295.10-1-6. 4. The location of underground improvements or encroachments,if any exist,oras shown hereon,are not certified. There maybe other underground utilities,the existence of which are unknown. Size and location of 5890121001Eall underground utilities must be verified by the appropriate authorities The Underground Facilities 164.54' bndaz8rouna I'rotectiveOro a f— - -- ---- lvzationmustbenokfiedpnortoconductingtestbonngs,excavationandconstruction ----- - Utilities I I -7 5. This survey wasprepared without the benefit ofan up to date abstract of title. I 611 6. Reproduction or copying of this documentmay be a violation of copylightlaw unless permission of the I author and/orcopynghtholder is obtained. I Septic I I Area per ' 7. A copy of this document without proper application of the surveyor's embossed seal should be assumed to I I Contractor ' be an unauthorized copy. 0 8. Setbacks shown perMap Reference 1. o � o�l L DEEDREFERENCE Fv I oodFrame Qa°elDwre 1. Conveyance to Patten Property Development,LLCbydeed dated March 17,2017,fVedin the Waren 0 Lands Now or Formerly of N N I Residence _ t,, County Clerks Office on March 23,2017m Book 5527of Deeds atpage 314. I Thomas D. Chase � I I �— �I J � M pd l� MAPREFERENCE Book 696 Poge 777 I r— Covered q Conc.Porch L Map entitled'Map ofStonecrofta Subdivision made forKenneth E.Mahoski;