RC-000220-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)76 1-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000220-2017 Date Issued: Wednesday, October 4, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000220-2017
has been completed.
Tax Map Number: 301.15-1-52
Location: 8 ELK RIDGE DR
Owner: FOOTHILLS BUILDERS, LLC
Applicant: FOOTHILLS BUILDERS, LLC
This structure may be occupied as a: Single-Family Dwelling 1,572 sq. ft.
Attached Garage 470 sq.ft. B,, Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the
Director aE'Building&Code Enforcement
Planning Board or Zoning Board of Appeals..
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000220-2017
Tax Map No: 301.15-1-52
Permission is hereby granted to: FOOTHILLS BUILDERS,LLC
For property located at: 8 ELK RIDGE DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvce of Construction
Owner Name: FOOTHILLS BUILDERS,LLC Single Family-New $150,000.00
Owner Address: 9 Mountainside DR Total Value $150,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
FOOTHILLS BUILDERS,LLC
9 Mountainside DR
Queensbury,NY 12804
Plans&Specifications
Single-Family Dwelling 1,572 sq.ft.
Attached Garage 470 sq.ft.
$1,234.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,May 23,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expp. ationAdate.)
Dated at the Town of eensbu { / /�'ues y 3,2017
SIGNED BY: /d for the Town of Queensbury.
Director of Building&Code Enforcement
PMC11PAL STRUCTURE APPLICATION Office Use Only
Date: S/ / 1 -1 Rd 02x0-cid I7
Permit No.
Tax Map ID 36 1. I S-I -(uyk Permit Fee /K O AI ,c,e
Zone (h D K Historic? _Yes D( No Rec Fee
d=
Subdivision Name E c.r- 911)&-e D R- Lot# Site Plan#
Project Location 2j,K e 1 (1)6-E- DA-Iv Subdivision
#
(z
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit fee(s).
Primary Owner(s) Foothills Builders E
Address 9 Mountainside Drive,Queensbury,NY 12804 D
Phone/Email (518) 796-3520/(518) 791-1933/FoothillsBuildersNY@gmail.com tl V '= 1y zu
Applicant Foothills Builders
TOWN OF DEVE OPMENT
EE BURY
Address 9 Mountainside Drive,Queensbury,NY 12804
Phone/Email (518) 796-3520/(518) 791-1933/ FoothillsBuildersNY@gmail.com
Contractor Foothills Builders
Address 9 Mountainside Drive,Queensbury,NY 12804
Phone/Email (518) 796-3520/(518) 791-1933/FoothillsBuildersNY@gmail.com
Sr8 "Jgl-i933
Contact Person for Building& Codes Compliance: _J0 e- Lis-(A (-1 Phone(Q01 -35-2 c
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration I"floor sf 2"1 floor sf Total sf Height
Single Family /S 7 Z
Two-Family CJ
Multi-Family
(#of units_)
Townhouse
Business Office
Retail-Mercantile
Factory-Industrial
Attached Garage
(1,("" 3, 4+) 1Y / �D �l7a
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2026
If commercial or industrial please indicate name of business
Proposed use of building or addition KES ID[NT i A l
Source of Heat(circle one) G Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning � ) ^
Appliances&Chimneys /V /A—
Are there structures not shown on plot plan? rry
Are there easements on the property? c
Site Information:
a. Dimensions or acreage of lot p,g A (-P-C-
b. Is this a corner lot? _Yes No
c. Will the grade be changed as a result of construction _Yes u( No
d. Public water or Private well(circle one) ubltc Private
e. Sewer or Private Septic System(circle one) Sewer <Znvat
Value of all work to be performed(labor or materials) $ l So , 00 U
DECLARATION.•
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes,local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: 70,S 6 P 14 LO'tn U DATE: S/S 117
SIGNATURE: / DATE: �_/( / )
For office use only U
Operating Permit Issued: _Yes —No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
SEPTIC DISPOSAL APPLICATION Office Use Only
Received
DATE: S 1 S I (� Tax Map ID
TAx MAP ID: Permit No.
Permit Fee
ZONE: M � (L
(518)796-3650/
APPLICANT Foothills Builders PHONE/E-MAIL 1 (518)791-1933
ADDRESS 9 Mountainside Drive Queensbury,NY 12804 FoothillsBuildersNY@gmail.com
INSTALLER/ PHONE/E-MAIL Same as above
BUILDER Foothills Builders
OWNER Foothills Builders
ADDRESS 9 Mountainside Drive Queensbury,NY 12804
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Joe Leuci
PHONE/E-MAIL (518)796/3520/ (518)791-1933/FoothiUsBuildersNY@gmail.com
RESIDENCE INFORMATION
Year Built #of bedrooms X gallons per bedroom --total Daily flow
1980 or older 3 J) Q3 3 0 Garbage grinder installed Yes No
1981-1991 Spa or Hot Tub installed Yes No
1992-Present
PARCEL INFORMATION
Topography Flat rolling _Steep slope _%Slope
Soil Nature _Sand _Loam _Clay _Other
Groundwater At what depth: PTA-
Bedrock
ABedrock/Impervious material At what depth: tJ A
Domestic Water Supply 'X-_Municipal _Well(if well,water supply from any septic system absorption is_ft.)
Percolation Test Rate: I - S per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED_SYSTEM FOR NEW CONSTRUCTION
Tank size 100 agallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub
System Absorption field with#2 stone Total length J ' --Oft.;Each Trench('
Seepage Pit with#3 stone How many: ;Size
Alternative System Bed or other type:
Holding Tank System Total required capacity? Tank size #of tanks_
Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will
no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the
septic system layout on file-no exceptions.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure
to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to
abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
PRINTNAME: -SOS C-P 4I DATE: (-k 17
SIGNATURE: � tti DATE: �-
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Town of Queensbury Thomas R. Van Ness
Highway Department Highway Superintendent
742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929
Phone: 518-761-8211
Fax: 518-745-4466 David Duell
Deputy Highway Superintendent
Home: 518-745-0938
DRIVEWAY PERMIT
Date: Os- l r1
Applicant Name: Foothills Builders
Telephone No.: (i l $ ) 7'T 1- 19 33 ( s l 8 -79 6-3 S Z
Address to be Inspected ( S El- K- K 1 p 6-C b !L v tr
Return Address: 9 Mountainside Drive Queensbury,NY 12804
Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes
at the specified location
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action
has been taken:
STEP 1: O Preliminary approval
NEED ( ) Slight Swale
( ) Deep Swale
( ) Level with the road
( ) Level with the top of the paved wing
Size culvert pipe to be used (if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36„
Preliminary inspection completed by: Date:
Approval by Highway Supt.: or Deputy Supt.:
Upon completion please resubmit this approval permit for a final approval.
STEP 2: ( ) Final Approval ( ) Rejected
Date:
Thomas R. Van Ness,Highway Superintendent David Duell, Deputy Highway Superintendent
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
LZ 0 - ZID(--
Permit No........................................Cert. NO 44980 Cut-in Card No.....................................
Owner. 0 1-14 5.) F;W
........................................ .....j�................................................................ ..........
�x.........
Location.... .......................................
Installatipri Consisting of...
V
.. ....Of...............................................
4*1- /,**"**....
.............. . .........
.................../.. ....................../. ......A
" A 1j.r_ .....Yzx'i?/&..........................................................
................................. ...... ........
Installed By........ F
......I .......................................Lic.No...................................................
. .... ...............
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment a,id installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making irojIMons at any time, and if its
Y7
.__,y
rules are violated,the Company shall have the right to 7vo his
s cc .
Date....q.,.2.4..... .......... INSPECTOR.... ZI... .....
....... .............
. ......................
aelnber N.F.P.A..I.A.E.I.
Manual S Compliance Report Job: ELKRIDGELOT2
Date: May 05,2017
Entire House By:
FE
� C V
Project Information
For: CERRONE TOWN OF QIUEENSBURY
QUEENSBURY, NY 12804 1 COMMUNITY DEVELOPMENT
Cooling Equipment
Design Conditions
Outdoor design DB: 85.07 Sensible gain: 22910 Btuh Entering coil DB: 75.3°F
Outdoor design WB: 71.0°F Latent gain: 5314 Btuh Entering coil WB: 62.6°F
Indoor design DB: 75.0°F Total gain: 28224 Btuh
Indoor RH: 50% Estimated airflow: 1096 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Split AC
Manufacturer: York Model: YCD30621+H,YE34(1,2)36+TM9Y06OB12MP11
Actual airflow: 987 cfm
Sensible capacity: 0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0°F Heat loss: 91331 Btuh Entering coil DB: 65.3°F
Indoor design DB: 68.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9X100C16MP11
Actual airflow: 987 cfm
Output capacity: 95000 Btuh 104% of load Temp. rise: 50 °F
301.15-1-52 RC-000220-2017
Foothills Builders
8 Elk Ridge Drive, Lot 2
Meets are all requirements ofACCA Manual S. SFD 1572 S.f., Garage 470 s.f.
2017-May-05 14:32:06
wrightSIDW Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
ACCP. ....IangeworthyMocuments\York\ELK RIDGE LOT 2 rup Calc=MJ7 Front Door faces: N
Residential — Review • Form
ACCPA /'�A RIPER 1
.• • System Design • • 15 Mar 09
r�mam.ycoa�er�
QUEENSBURYNY
Header Information
Contractor: REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes E No ❑
Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes No FJ
OEM performance data(healing,cooling,blower): Yes No
Building plan* Manual D Friction Rate Worksheet: Yes No
Home address(Street or Lot#,Block,Subdivision): , Entire House Duct distribution sketch: Yes [ No E]
HVAC • .D CALCULATION (IRC M1401.3)
Desiqn Conditions Buildinq Construction Information
Winter Design Conditions Building
Outdoor temperature: _4 °F Orientation: Front Door faces North
Indoor temperature: 68 ^F North,East,West.South,Northeast,Northwest,Southeast,Southwest
Total heat loss: 91331 Btuh Number of bedrooms: 3
Conditioned floor area: 4826 ft'
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 °F Windows Roof
Grains difference: 27 gr/Ib @60% RH Eave overhang depth: 0 it
Sensible heat gain: 25456 Stull Internal shade: none
Latent heat gain: 5905 Stull anaa.,arapes,eec' o pb window
Total heat gain: 31361 Btuh Number of skylights: 0
EQUIPMENTHVAC • •
Heating Equipment Data Cooling Equipment Data Blower Data
Equipment type: Gas furnace Equipment type SplitAC Healing cfm: 987
umace,Heatpump,Boller,etc. Ir unehioner,Neat pump,etc. Cooling cfm: 987
Model: York Model: York Static pressure: 0 in H2O
TM9X100C16MP11 YCD30821 Fan's rated external static pressure for
eesign ahNow
Heating output pa ity at 95Qe00 Btuh Total cooling capacity: 0 Btuh
Heat pumps-capacHy at Interaeaiga oa dor conditions Sensible cooling capacity: 0 Btuh
Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
HVAC DUCT DISTRIBUTION ••
Design airflow: 987 cfm Longest supply duct: 0 ft Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct:
Total device pressure losses: 0 in H2O Total effective length(TEL): 0 it
Available static pressure(ASP): 0 in H2O Friction rete: n in/100ft Branch duct: Sheet metal
Friction Rate=ASP+)TELx 10b)
I declare - load calculation,equipment equipment selectonand duct designwererigorously performed based
plan listed above. I understand the claims made on these forms will be subject to review and verification.
Contractor's printed name:
Contractor's signature: Date:
MunicipalityReserved for County,Town
'Home qualifies for MJ1AE Form based on Abridged Edition Checklist
* wrightSOW Right-Suee®Universal 2017 17.0.16 RSU25116
Pro ect Summar Job: ELKRIDGELOT2
Entire House y Byte: May 05,2017
Proiect Information
For: CERRONE
QUEENSBURY, NY 12804
Notes:
Design • •
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db -4 OF Outside db 85 OF
Inside db 68 OF Inside db 75 OF
Design TD 72 OF Design TD 10 OF
Daily range M
Relative humidity 50 %
Moisture difference 27 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 85920 Btuh Structure 21842 Btuh
Ducts 5411 Btuh Ducts 1068 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none
Humidification 0 Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 91331 Btuh Use manufacturer's data n
Ratelswing multiplier 0.90
Infiltration Equipment sensible load 20619 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 5314 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(fta 4828 4826 Equipment latent load 5314 Btuh
Volume?1 43434 43434
Air changes/hour 0.70 0.40 Equipment total load 25933 Btuh
Equiv.AVF(cfm) 507 290 Req. total capacity at 0.70 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade ADP
Model TM9X100C16MP11 Cond YCD30B21
AHRI ref 2008692 Coil
lref 8$492681,2)36+TM9YO60B12MP11
AHRIEfficiency 95.5AFUE Efficiency 12.0 EER, 14 SEER
Heating Input 100000 Btuh Sensible cooling 20720 Btuh
Heating output 95000 Btuh Latent cooling 8880 Btuh
Temperature rise 88 OF Total cooling 29600 Btuh
Actual air flow 987 cfm Actual air flow 987 cfm
Air flow factor 0.011 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
wri htSofY' 2017-May-0514:32:06
9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
ACCK ....langeworthy\Documents\York\ELK RIDGE LOT 2.mp Calc-MJ7 Front Doorfaces: N
Right-J® Worksheet Job: ELK RIDGE LOT 2
Entire House Date: May 05,2017
By:
MANUAL J:7th Ed.
1 Name of morn Entire House Roolnl Room2 Rcom3
2 Length of exposed wall 5520 1t 184.0 ft 184.0 It 14.0 ft
3 Room dimensions 1.0 x 1586 ft 1.0 x 1620 It 8.0 x 6.0 1t
4 Ceilings 1 Condit.Option 9.0 ftl d 9.0 ftl heat/cod 9.0 ftl heat/cool 9.0 ft 1 heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(stub) Arm Load(stub) Area Load(Btuh)
EXPOSURE NO. Htg I Clg (W) Htg I Clg (It") Htg I Clg (ft2) Htg I Cig (ftl Htg Cls
5 Gross a 12E3 5.4 1.0 4968 `••• 1656 "" •"• 1656 •••• •••• 126 •••• '••'
Exposed b 0 0 111111 •••• •••• II!!!! "•• ^••« !!1111 •••• «"« II!II! ••'• ""
walls and c 0 0 111111 •••• •••• II!!!! ••'• »» 111111 •••• »» !11111 »» •»•
partitions d 0 0 111111 •» •••• 111!11 '••` '» !!!I!I •» '» !!!!!! »• '••
e 0 0 !!1111 •» »•• III!!! »» •• !!!!I! •» I!!!!! .•• •••
f 0 0 IIIII --- IIIII! '»• •'• IIIII! I111 •••
6 Windows and a 3D0 26.0 295 7668 '••• 65 1689 '»' 0 0 - 10 260 ""
glass doors b 0 0 0 - 0 0 "` 0 0 .,` 0 0 "'
Heating c 0 '" 0 0 "" 0 0 "'• 0 0 •••' 0 0 '••'
d 0 ` 0 0 "" 0 0 •" 0 0 "' 0 0 "•
e 0 •' 0 0 "•• 0 0 '••• 0 0 "" 0 0 "••
f 0 0 0 •'•• 0 0 ••• 0 0 "' 0 0
7 Windows and Nath 17.0 135 "" 2295 20 "'• 340 0 •••• 0 0 - 0
glass doors NE/NW 0 0 •••• 0 0 "'• 0 0 •••• 0 0 •••• 0
Coding E/W 62.0 85 •••• 5270 45 "'• 2790 0 •"' 0 10 - 820
SE/SW 0 0 '"' 0 0 ••'• 0 0 "' 0 0 '"' 0
South 30.0 75 •`• 2250 0 '•*• 00 •" 0 0 "• 0
Hoe 0 0 0 0 "'• 0 0 ••` 0 0 "` 0
8 Other doors a 10DO 33.1 6.3 84 2782 526 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
C 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 4589 24781 4681 1591 8591 1623 1658 8942 1689 116 625 118
exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
walls and c 0 0 111111 0 0 III!!I 0 0 111!11 0 0 111111 0 0
partitions d 0 0 11!111 0 0 1111! 0 0 11!111 0 0 111111 0 0
e 0 0 ll!!!! 0 0 II!!!! 0 0 111111 0 0 111111 0 0
f 0 0 111111 0 0 1!11!! 0 0 JIM! 0 0 I!1!11 0 0
10 Ceilings a 1600 2.4 1.1 3240 7698 36350 0 0 1820 3849 1818 48 114 54
b 0 0 111111 0 0 Jill it 0 0 111111 0 0 !!!III 0 0
c 0 0 111111 0 0 !111!1 0 0 111111 0 0 111111 0 0
d 0 0 111111 0 0 1111!1 0 0 111111 0 0 IMM 0 0
e 0 0 111111 0 0 111111 0 0 1!1111 0 0 111111 0 0
f 0 0 111111 0 0 111111 0 0 1!11!1 0 0 111111 0 0
11 Floors a 1910 1.7 0 1586 2741 0 15% 2741 0 0 0 0 0 0 0
(Note:rain b 1910 1.7 0 68 118 0 0 0 0 34 59 0 8 14 0
Perimeter c 0 0 111111 0 0 111111 0 0 HIM 0 0 111111 0 0
is displ. d 0 0 111111 0 0 111111 0 0 111111 0 0 11111 0 0
for slab e 0 0 111111 0 0 !!1!!! 0 0 111111 0 0 111111 0 0
floors) f 0 0 111111 0 0 1!!!!! 0 0 111111 0 0 111111 0 0
12 Infiltration a 106 8.4 379 40133 3185 65 8863 546 0 0 0 10 1059 84
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 ••' 85920 "" •"' 19904 "• "' 12850 ••• 20-M •"
Less external heating •»• 0 »» ••« 0 •••• •••• 0 •••• ••» 0 ••••
Less transfer •'• 0 •»• ••» 0 `•" ••• 0 •» •» 0
Heating redisMbution ••• 0 ,••• ••» 0 ••• ,» 0 •:• ••• 0 •••
14 Duct loss • 6% 5411 - 60/0 1254 "" 6% 809 "" 6% 131 '•••
15 Total loss=13+14 "" 91331 •'•• •••• 21158 "'• - 13660 "" '»• 2204 '•'•
16 Int.gains: People@ 300 0 •'•• 0 0 •••• 0 0 •"• 0 0 - 0
App1. @ 1200 0 •••• 0 0 •••• 0 0 '"` 0 0 «» 0
17 Subtot RSH gain=7+8.+12+16 ""' '••• 21842 "" "•• 5299 '•" •"' 3507 •••• •••' 876
Less external coding •••• »•• 0 •»• •„• 0 •»• •••• 0 •••• •••• p
Less transfer ••» ••» 0 ••» »» 0 "» •••• 0 ••» ••» 0
Coding redistribution "•' •••• 0 •••• "" 0 •»' •••• 0 •••• ••» 0
18 Dud gain 5% "" 1068 5% - 259 5% "" 172 5% "" 43
19 Total RSH gain=(17+18)•PLF 1.00 •••• 22910 1.00 - 5558 1.00 "" 3678 1.00 "" 919
20 Air required(cfm) 987 987 229 239 148 158 24 40
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
Wrights4af!- Right-Su 2017-May-0514:32:06
.�. Fmi16 Page 1
....lengeworthy\Documents\York\ELK RIDGE LOT 2.mp Calc=MJ7 J7 Front Door faces: N
Right-J@ Worksheet Job: ELK RIDGE LOT
Entire House Date: May 05,2017
By:
MANUAL J:7th Ed.
1 Name of morn Room4 RoornS Rown6 Room7
2 Length of exposed wall 78.0 It 10.0 ft 320 ft 0 ft
3 Room dimensions 1.0 x 8420 ft 10.0 x 5.0 ft 16.0 x 16.0 ft 5.0 x 11.0 ft
4 Ceilings 1 Condit.Option 9.0 it 1 heat/cod 9.0 ftl heat/cool 9.0 It heallcod 9.0 ft heat/c001
TYPE OF CST HTM Arm Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Stub)
EXPOSURE NO. Htg I Clg (ftp Htg I Clg (ftp Htg Clg (ft') Htg I Clg (115 Htg I Clg
5 Gross a 12E3 5.4 1.0 702 '•• •`•• 90 ••» •• 2880 •» ••
Exposed b 0 0 111111 •"• "•• III!!! »'• »•• HIM �"' '^• 111111 '»' »••
walls and c 0 0 111111 •••• `••• 1111!! •»• •»• 111111 '•" •••• 111111 ""' ••"•
paditions d 0 0 1!!!!I "•• "" Ilnl� •••• ••^` 111111 "» •`•` 111111 •"• "•`
e0 0 I!I!II "'• •••• 1111!! •••• ••^^ 111111 "" "•"` 111111 "•• `•••
f 0 0 IIIII "`• »» 1111!! •••• «« 111111 •••• ,••, Mill •••• ««
6 Windom and a 3D0 25.0 » 1o5 2729 - 10 260 - 45 1170 "" 0 0 -
glass doors b 0 0 0 '••• 0 0 - 0 0 '•• 0 0 ,
Heating c 0 0 0 "'• 0 0 ••` 0 0 "` 0 0 '•'
d 0 0 0 "" 0 0 '•` 0 0 ••• 0 0 ....
e 0 ` 0 0 "" 0 0 "' 0 0 "" 0 0 •"
I 1 0 0 0 "`• 0 0 ••• 0 0 "• 0 0 •••
7 Window and Nalh 17.0 75 "•• 1275 10 »» 170 30 •••• 510 0 "» 0
glass doss NE/NW 0 0 "•` 0 0 "» 0 0 `••• 0 0 `••` 0
Cooling E/W 620 15 "" 930 0 "» 0 15 "" 930 0 •••• 0
SE/SW 0 0 •" 0 0 "'• 0 0 „` 0 0 "` 0
South 30.0 15 '•' 450 0 "" 0 0 ^" 0 0 0
H= 0 0 - 0 0 "" 0 0 "' 0 0 0
8 Other doors a 10DO 33.1 6.3 84 2782526 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 513 2770 52380 432 82 243 1312 248 0 0 0
exposed b 0 0 Mill 0 0 IIIII! 0 0 111111 0 0 111111 0 0
walls and c 0 0 1!!1!1 0 0 1111!! 0 0 1!111! 0 0 111111 0 0
partitions d 0 0 !!Ill! 0 0 1111!! 0 0 11111! 0 0 111111 0 0
e 0 0 111111 0 0 !!I!!! 0 o Mill 0 0 111111 0 0
f 0 0 HIM0 0 111111 0 0 111111 0 0 111111 0 0
10 Ceilings a 1660 24 1.1 842 2001 945 50 119 56 256 608 287 55 131 62
b 0 0 !IIIII 0 0 IMI! 0 0 111111 0 0 111111 0 0
c 0 0 1111!! 0 0 I!!I!! 0 0 111111 0 0 III!II 0 0
d 0 0 111111 0 0 1111!! 0 0 111111 0 0 111111 0 0
e0 0 I!II!! 0 0 I!!!!! 0 0 111111 0 0 111111 D 0
f 0 0 !!1!!! 0 0 Hill! 0 0 111111 0 0 111111 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
(Note:roam b 1810 1.7 0 26 45 0 0 0 0 0 0 0 0 0 0
pedmeter c 0 0 HIM 0 0 IIIII! 0 0 Mill 0 0 1!1111 0 0
is disp. tl 0 0 HIM 0 0 Hill! 0 0 !111!1 0 0 111111 0 0
fa slab e 0 0 1111!1 0 0 111111 0 0 Mill 0 0 111111 0 0
floors) f 0 0 111!11 0 0 111111 0 0 111111 0 0 111111 0 0
12 Infiltration a 108 8.4 189 20014 1588 10 1059 64 45 4765 378 0 0 0
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=S+8.+11+12 ,»` 30341 "'• ,,,, 1870 •••` "•• 7855 "" '•`• 131 »••
Less external heating »» 0 •••• •••• 0 ••« ,••• 0 "'•` •«• 0 ,,•,
Less transfer •••• 0 "'• •••• 0 •••• •••• 0 •`•• •«• 0 «••
Heating redstdbution *»• 0 "`• •••• 0 •••• •••• 0 •••• ••« 0 «••
14 Duct loss 6% 1911 "" 6% 118 •"` 5% 495 •"` 6% 8 »•'
t5 TOW loss=13+14 » 32251 •»• - 1987 •» »• M ••• ••• 139
16 Int.gains: People @ 3D0 0 '••• 0 0 •••• 0 0 "" 0 0 "" 0
Appl. @ 1200 0 •••• 0 0 "" 0 0 "•» 0 0 ••. 0
17 Subtot RSH gain=7+8..+12+16 •"` »•• 6237 »•• "" 392 '•» "» 23W `•^' `^» 82
Less external coding •••• •••• 0 •••• •'« 0 ••« ,,•• 0 •••• •••• 0
Less transfer •••• «« 0 •••• «,• o «« «« 0 •••• ••« 0
Coding redistdGAion •••• •,•• 0 •••• "" 0 - 0 0 •••• •••• 0
18 Duct gain 5% '••' 305 5% »'• 19 5% `•. 115 5% 3
19 Total RSH gain=(17+18)•PLF 1.00 •'•• 6542 1.00 •••` 411 1.00 "" 2468 1.00 "" 65
20 Air mquired(cfm) 3481 282 21 18 90 106 2 3
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
TIj- wrightsoft' 2017-May-0514:32:06
Right K RID E LOT 2.rup 7 17.0.18 J7 Fm16 Page 2
/� ....langeworthy\Documents\York\ELK RIDGE LOT 2.rup Cak=MJ7 Front Dow faces: N
Right-JO Worksheet Job: ELK RIDGE LOT
Entire House Date: May 05,2017
6y:
MANUAL J:7th Ed.
1 Name of earn Roome Room9 Room10
2 Length ot exposed wall 0 it 23.0 ft 27.0 ft
3 Room dimereicre 5.0 x 11.0 it 11.0 x 120 it 14.0 x 13.0 it
4 Ceilings I Condl.Option 9.0 ft 1 heall000l 9.0 ftl heattcool 9.0 ft heatfood
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area
EXPOSURE NO. Htg I Clg (ft5 Htg I Clg (ftp Htg f Clg (ft2) Htg I Clg Htg I Clg
5 Gross a 12E3 5.4 1.0 0 — .TM` 207 •••• »' 243 "•• «'• «•• ••••
Exposed to 0 0 Mill 'TM` "" 111111 ••`• '» 1111!! »• "" »• ••'•
walls and c 0 0 111111 _» •'« 111111 •«• « 1111!! .„ •••
Partitions 0 0 fill " "" !!1111 «` 1111!! 'TM ' •••
00 0 111111 »` "" Mill — •'« I!!!!! " ~
•• ' ' ••••
f 0 0 111111 •••• »` 111111 ••.. •••• !!!1!! .... ..TM ••« ••••
6 Windows and a 3D0 26.0 •• 0 0 .... 30 780 •«• 30 780 •••• ••••
glass doors b 0 •• 0 0 '» 0 0 "" 0 0 •••• «••
Heating c 0 0 0 0 0 «' 0 0 `•` •"
d 0 0 0 "" 0 0 0 0 '•
e 0 0 0 "" 0 0 0 0 «`
f 0 0 0 «" 0 0 0 0 `
7 Windows and North 17.0 0 "" 0 0 •» 0 0 "" 0
glass doors NEINW 0 0 •••. 0 0 `«• 0 0 »` 0 'TM
Coding E/W 620 0 •... 0 0 `» 0 0 •"' 0 "'
SEISW 0 0 •'• 0 0 •TM• 0 0 '« 0 »
South 30.0 0 •••• 0 30 »• 900 30 "" 900 "•'
8 Other doors a tODO 33.1 6.3 0 0 0 0 0 0 0 0 0
to 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 0 0 0177 956 181 213 1150 217
exposed b 0 0 111111 0 0 1!!!!1 0 0 111111 0 0
walls and c 0 0 111111 0 0 II!!!! 0 0 111111 0 0
partitions d 0 0 111111 0 0 Illlll 0 o mut 0 0
e 0 0 111111 0 0 111111 0 0 11!!!! 0 0
f 0 0 Illlll 0 o flim 0 0 [Mill 0 0
10 Ceilings a 16G0 2.4 1.1 65 131 62 132 314 148 182 432 204
to 0 0 111111 0 0 111111 0 0 1!1!11 0 0
c 0 0 Illlll 0 0 111111 0 0 IlIM 0 0
It o o mut 0 0 111111 0 0 111111 0 0
e 0 0 111111 0 0 111111 0 0 11111! 0 0
f 0 0 111111 0 0 1111111 0 0 1111111 01 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0
(Note:man b 1910 1.7 0 0 0 0 0 0 0 0 0 0
penmeter c 0 0 !11111 0 0 II!1!! 0 0 111!11 0 0
is displ. d 0 0 111111 0 0 !!!!I! 0 0 !!!!!! 0 0
fa slab e 0 0 1!1111 0 0 Im II 0 0 Hilt 0 0
floors) f 0 0 Illlll 0 0 Illlll 0 0 111111 0 0
12 Infiltration a 106 8.4 0 0 0 30 3177 252 30 3177 252
Ventilation o 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 •••• 131 "" * 5226 .... "" 55M •» »• ^^
Less external healing •••• 0 ...` •••• 0 •.« TMTM 0 •,,• •••• •••.
Less transfer •••• 0 •TM' •••• 0 `••• TM.. 0 .TM. «.• ....
Heating redstdbution •••• 0 "" — 0 «« .... 0 --- «« ....
14 Duct loss 6% 8 '•" 6% 329 »' 6% 349 '» •••
15 Total loss=13+14 •••• 139 '» •'« 5555 «'• ••'• 5888 "" »• '•••
16 Int.gains: People @ 300 0 "" 0 0 .... 0 0 ••TM 0
Appl. @ 1200 0 "" 0 0 `... 0 0 — 0 TMTM
17 Sudot RSH gain=7+8..+12+16 ••'• `••• 62 •••` "" 1481 «'• "': 1574
Less external coding •••• •••• 0 •.•• •••• 0 •••• ,,,• 0 •"• ••«
Less transfer •••• •«• 0 •••• »•• 0 •••• •••• 0 ••« ..«
Coding redistribution •••' •••• 0 •«• •«• 0 •«• •••• 0 ••« ••••
18 Duct gain 5% "' 3 5% •••` 72 5% ••• 77 «
19 Total RSH gain=(17+18)'PLF 1.00 "" 65 1.00 »` 1553 1.00 •... 1651 "'•
20 Air required(otm) 2 3 60 67 64 71
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
L' wr➢ghtsOTi' 2017-May-0514:32:06
Right-Suite®Universal 201717.0.16 RSU25116 Page 3
....langewodhy\Documents\York\ELK RIDGE LOT 2.mp Calc=MJ7 Front Door faces: N
CRESeheck Software Version 4.5.4
�(J Compliance Certificate
Project p G C Fp- fE
Energy Code: 2015 IECC '^
Location: Glens Falls, New York
Construction Type: Single-family TOWN OF QUEENSBURY
Project Type: New Construction COMMUNITY DEVELOPMENT
Conditioned Floor Area: 1,572 ft2
Glazing Area 16%
Climate Zone: 6 (7635 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Foothills Builders Vision Engineering, LLC
Elk Ridge 206 Glens Street
Lot 2 Suite 56
Queensbury, NY 12804 Glens Falls, NY 12801
Compliance: Passes using UA trade-off
Compliance: 0.7%Better Than Code Maximum UA: 269 Your UA: 267
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont U-Factor UA
Assembly or R-Value R-Val,e
Perimeter
Wall 1:Wood Frame, 16" D.C. 1,638 21.0 0.0 0.057 78
Window 1:Vinyl Frame:Double Pane with Low-E 200 0.290 58
Door 1: Glass 40 0.290 12
Door 2: Solid 18 0.140 3
Door 3: Solid 20 0.200 4
Ceiling 1: Raised or Energy Truss 1,572 38.0 0.0 0.025 39
Basement Wall 1: Solid Concrete or Masonry 1,420 0.0 15,0 0.046 64
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth: 7.8'
Window 2:Vinyl/Fiberglass Frame:Double Pane 9 0.400 4
Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5
301.15-1-52 RC-000220-2017
Foothills Builders
8 Elk Ridge Drive, Lot 2
SFD 1572 s.f., Garage 470 s.f.
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES- FHB Page 1 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Compliance Statement: The proposed building design descr!Pvd here is consistent with the building plans,specifications, and other
calculations submitted with the rmit application.The pro d building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and comply with the mandatory a uirements listed in the REScheck Ins ction Checklist.
Name-Till Signa re Dfe 1)
F NF
n A
o ti0
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240- DES - FHB Page 2 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
REScheck Software Version 4.6.4
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Fie Verified
# Pre-Inspection/Plan Re iew Complies? Comments/Assumptions
& Re .ID Value Value
103.1, :Construction drawings and ❑Complies
103.2 ;documentation demonstrate ❑Does Not
[PR111 energy code compliance for the
40 building envelope.Thermal ❑Not Observable i
envelope represented on ❑Not Applicable j
construction documents.
103.1, ..Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable14, 1
Systems serving multiple ;❑Nat Applicable j
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
v Manual J or other methods Btu/hr ; Btu/hr
approved by the code official ❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 12'' Medium Impact(Tier 2) 3 ILow Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES- FHB Page 3 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R-_ ❑Complies ',See the Envelope Assemblies
[F0411 insulation R-vaiue.Where interior R- R- '❑Does Not table for values.
49 insulation is used,verification : ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ;! ! ❑Complies
[F0511 insulation installed per ❑Does Not
manufacturer's instructions. , []Not Observable :.
^;❑Not Applicable
402.2.9 ;Conditioned basement wall it _ft ❑Complies See the Envelope Assemblies
[FO611 insulation depth of burial or ❑Does Not :table for values.
;distance from top of wall.
[]Not Observable
❑Not Applicable
303.2.1 ':'A protective covering is installed " ❑Complies
[FOIJ]2 Ao protect exposed exterior ��❑Does Not
;insulation and extends a ❑Not Observable
1 minimum of 6 in. below grade.
❑Not Applicable j
403.9 !Snow-and ice-melting system ❑Complies
[FO12]2 controls installed. EJ Does Not
Ab' ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 JHigh Impact(Tier 1) Medium Impact(Tier 2) 1,3; Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES- FHB Page 4 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section Plans Verified Field Verified
# . Framing/ Rough-in Inspection "' Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not 'table for values.
[FRI]' ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U-_ ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, :❑Not Observable
402.5 ❑Not Applicable j
[FR211
303.1.3 IU-factors of fenestration products ❑Complies
[FR411 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table. 9.❑Not Applicable j
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR2311 installed per manufacturers ❑Does Not
instructions.
[]Not Observable
❑Not Applicable j
402.4.3 Fenestration that is not site built ❑Complies
[FR2011 is listed and labeled as meeting - ': ❑Does Not
-AAMA IWDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
;400 that do not exceed code ';❑Nat Applicable j
limits.
402,4.5 IC-rated recessed lighting fixtures ❑Complies
(FR1612 sealed at housing/interior finish -.❑Does Not
and labeled to indicate s2.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable
403.2.1 Supply and return ducts in attics - ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not j
>=3 inches in diameter and >_ ❑Not Observable
R-6 where < 3 inches.Supply and
return ducts in other portions of ❑Not Applicable
the building insulated>= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter. _
403.3.3.5 Building cavities are not used as - ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
ko ❑Not Observable 1
❑Not Applicable j
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 QF or chilled fluids ❑Does Not
below 55 9F are insulated to >_R-3. ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
+by ❑Not Observable i
❑Not Applicable j
40353Hot water pipes are insulated to R- R-_ ❑Complies
[FR18]' >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable j
403.6 Automatic or gravity dampers are ❑Complies
[FR191' installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Nat Observable
❑Not Applicable j
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES - FHB Page 5 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Additional Comments/Assumptions:
1 High Impact(Tier 1) :2::. Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES - FHB Page 6 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
303.1 All installed insulation is labeled ' ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
_ ❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- — R- J❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [--]Not Observable
[IN311 exterior,the exterior insulation
;requirement applies(FR10). E] Steel ElSteel ❑Nat Applicable j
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
.. ❑Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240- DES - FHB Page 7 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section PlansberifledField Verified
# Final Inspection Provisions. Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood -❑Does Not table for values.
402.2.2• Steel ❑ Steel
[]Not402.2.6 ❑ Not Observable
[Fill' ❑Not Applicable
303.1.1.1,;Ceiling insulation installed per ❑Complies
303.2 -manufacturer's instructions. ❑Does Not
[F1211 ;Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable j
402.2.3' ".i Vented attics with air permeable ❑Complies
[F122l2 insulation include baffle adjacent ❑Does Not
j to soffit and eave vents that
:3 extends over insulation. ❑Not Observable
❑Not Applicable j
402.2.4 Attic access hatch and door R-_ R-_ ❑Complies '
[FI311 insulation aR-value of the - ❑Does Not
',-adjacent assembly. j❑Not Observable
❑Not Applicable
402.4.1.2 4Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ❑Complies
[FI1711 :ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable j
403.2.3 Duct tightness test result of<=4 cfm/100 - cfm/100 ❑Complies
[FI411 cfm/100 ft2 across the system or ft2 ! ft2 ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
'tests,verification may need to :❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI2711 determine air leakage with ft2 ❑Does Not
Ieither: Rough-in test:Total
'..leakage measured with a ❑Not Observable 1
pressure differential of 0.1 inch ❑Nat Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
'.leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 'Air handler leakage designated ❑Complies
[FI2431 i by manufacturer at<=2%of El Does Not
;design airflow. ❑Not Observable
❑Not Applicable
"Programmable thermostats ❑Complies
installed for control of primary ❑Does Not
heating and cooling systems and
M initial) set b manufacturer to ❑Not Observable
i• .code specifications. ❑Nat Applicable j
Heat pump thermostat installed ❑Complies
v �
on heat pumps. - ❑Does Not
❑Nat Observable I
❑Not Applicable
Circulating service hot water ❑Complies ;
ars- I systems have automatic or ❑Does Not
accessible manual controls.
[]Not Observable
i
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES -FHB Page 8 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req,ID
403.6.1 All mechanical ventilation system ❑Complies
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air Flow limits. �❑Not Observable
_ t❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback ❑Not Observable
control to lower boiler water
temperature based on outdoor ❑Not Applicable
temperature.
403.5:1.1 Heated water circulation systems ❑Complies
[FI2812 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems - ❑Complies
[FI2912 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
IF13012 have recirculation pumps that ❑Does Not
pump water from a heated water - ❑Not Observable
supply pipe back to the heated
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F.
403.5.4 Drain water heat recovery units ❑Complies
[FI31]2 tested in accordance with CSA []Does Not
B55.1.Potable water-side
pressure loss of drain water heat []Not Observable
recovery units< 3 psi for []Not Applicable
individual units connected to one
or two showers.Potable water-
side pressure loss of drain water
heat recovery units<2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent i ❑Complies
[FI611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
@: ❑Not Observable
❑Not Applicable j
11 High Impact(Tier 1) 2 Medium Impact(Tier 21 3 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240- DES-FHB Page 9 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
Value Value
& Req.ID - l
401.3 Compliance certificate posted. ❑Complies
[F1712 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F11813 mechanical and water heating ❑Does Not
,systems have been provided.
❑Not Observable I
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Report date: 05/05/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1240 - DES - FHB Page 10 of 10
Lot 2 Elk Ridge\1240 Rescheck.rck
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.29
Door 0.29
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater: _
Name: Date•
Comments
301.15-1-52 RC-000220-2017
Foothills Builders
8 Elk Ridge Drive, Lot 2
SFD 1572 s.f., Garage 470 s.f.
LEGEND
� C E 0W17E
IRF IRON ROD FOUND
IPF IRON PIPE FOUND I I,
IRS IRON ROD SET AY
`o� UTILITY POLE N
moo STONE WALL TOWN OF QUEENSBURY
x WIRE FENCE COMMUNITY DEVELOPMENT
— o CHAIN LINK FENCE
❑ — WOOD FENCE
Lands n/f C POINT
Kathleen Hudson F.P. FENCE POST
LOT 7 ohw— OVERHEAD WIRES X
L. 758 P. 195 n/f NOW OR FORMERLY s�
S83-20'35 nE � ,
287. water
F
7¢' shut off�s
I _
Lands n/f — — — 25' SIDE BUILDING SE MAP REFERENCE:
Christopher M. Bartley ANGLE v 203.3' — —TBACK— _ 33.0' 1) "MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC'
& Jammie M. Bartley shed IRON F-0 T_ — — — 3 DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL
LAND SURVEYORS.
L. 3124 P 180 �, . N i LOT 2 >�, w
op AREA = CV
PROPOSED a--
SEPTIC a 1
SEPTIC Z m W
s � NOTES: w
" f 0.85± ACRES j "'m N 0 13
catch o 1) BASE MAP PREPARED FROM A JANUARY 2014 FIELD SURVEY.
Z Q waterer basins Q:shut off ,
M L PROPOSED , O 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1. 4
FOUNDATION
PROPOSED f 3) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT
/ DRIVEWAY ! OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS
25' SIDE SUI�DI�6�/SE�ACK — _ V9 1 OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT
Lands n/f — — — — _}J 7�1 WOULD DISCLOSE.19
0.
Douglas H. Olds 287.64' 36.9' 00 hydrant 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE
L. 1004 P. 196 REGARDING DEVELOPMENT OF LAND.
N83'20'35 W
' 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND
SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE
'^ NEW YORK STATE EDUCATION LAW.
o `�J
LOT 3 - 6) ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE
r LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.
0 0 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM
SURFACE LOCATIONS AND MEASUREMENTS OBTAINED FROM A FIELD SURVEY.
THERE MAY BE OTHER UTILITIES WHICH THE EXISTENCE OF ARE NOT KNOWN. SIZE,
TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY
PP1�-9{ r-= � PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR
I I-IAvE P[rIl-'Ui', f_ !'�( Ji:: G TO ANY EXCAVATION.
�MMET TF� PLOT PLAN MADE FOR
FOOTHILLS BUILDERS LLC
GRAPHIC SCALE
505 Town of Queensbury County of Warren State of New York
50 0 25 50 100 200 IM^E r= E.
1100A RD
MCFAVSED LAND SURVEY111IG
342 Main Street, Hudson Falls, New York 12839
( IN FEET ) Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 04/26/17 Sheet Of of 01
I inch = 50 ft.
Date Sealed:;] p/ j7 Scale: 1 inch = 50 feet Revised: Drawing #:13074L2PP
NORTH EAST BUILDING PERFORMANCE ADVISORS
...........................................................................................................................................
Serving the Capital District, Saratoga and Adirondack Regions
June 13, 2017 7 Rocky Ridge, Warrensburg,NY 12885
Foothill Builders LLC
9 Mountainside Drive
Queensbury,NY 12804
RE: Blower Door Test for NYS Building Code, Town of Queensbury
Mr. Joseph Leuci:
After inspection of the New 1 Story Home at 8 Elk Ridge Dr., Queensbury,New
York and completion of a Blower Door Test consistent with the practice of
depressurization to 50 Pascal in a winter condition with the exterior windows and
doors shut and the interior doors to all the rooms open, my observations are as
follows:
❖ This home tested passed the current New York State Building Code for Air Changes
per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after
November 1St, 2016). The tested number is 2.89 ACH/50 Pascal.
❖ The total volume of conditioned space at 31 Elk Ridge Dr. is 26357 cubic feet taking
into consideration all conditioned space in the home. The cubic feet per minute @ 50
Pascal was 1271 CFM/50. The height correction factor for New York State is 19 for
a one story building, as such the tested home @ 31 Elk Ridge Dr. has the natural rate
of air exchange of 0.15 air changes per hour/natural or 66.89 cfm natural infiltration
credit based on the blower door test.
❖ In the latest(2013)version of ASHRAE 62.2, high-performance homes need to be
ventilated at 7.5 cfm per person plus 3 cfin per 100 square feet. That means for 2
people it would need 1570 sq ft/100 times 3 plus 30 cfm or 77 cfm. It would also be
advantageous to use the bathroom and kitchen fans to help control humidity and
improve indoor air quality.
❖ My credentials are as follows:
➢ BPI Certified Building Analyst
➢ BPI Certified Envelope Specialist
➢ BPI Certified Heating Professional C 22-0 ^ ZO i�-
➢ HERS Rater
❖ If you have any questions regarding my findings
DE Vt
Sincerely, � v
ja,c-k 7'o-wYt& OCT 0 3 2017
TOBUNLD Y
G&CdDES
1.888.472.2774
7 Rocky Ridge Road 4A Vatrano Drive
Warrensburg,NY 12885 Albany,NY 12205
Phone (518)623.7016 Phone (518)350.2941
Fax (518)623.7015 Fax (518)694.0102
t
NACE R P.C.
169 Haviland Road, Queensbury, NY 12804
Phone-518-745-4400 Fax - 518-792-8511
October 3, 2017
Job # 46262
Dave Hatin
Town of Queensbury Building Department
Bay Road
Queensbury, NY 12804
RE: Leuci Peggy Ann Road Subdivision - Queensbury(T)
Lot # 2 Septic System
Dear Dave:
This letter is to inform you that we inspected the completed septic system for the house at Lot# 2
in the Leuci Peggy Ann Road Subdivision on August 25, 2017.
The septic system as installed was for a three bedroom house and consisted of a 1,000 gallon
septic tank and 150 lineal feet of absorption trench constructed with stone and perforated pipe.
The system conforms to the requirements of the approved subdivision design drawings.
Please call me if you have any questions or concerns.
Sincerely,
E
Thomas R. Center Jr., PE
011
NSBURY
ODES
QL- 2'7� • 7A�+
i
GRAPHIC SCALE E N
50 0 25 50 100 200
IRF IRON ROD FOUND
IPF IRON PIPE FOUND
IN FEET IRS IRON ROD SET
Cal UTILITY POLE
1 inch = 50 ft. o00o STONE WALL
X WIRE FENCE
o CHAIN LINK FENCE
❑ WOOD FENCE
Lands n/f ® POINT
Kathleen Hudson
F.P. FENCE POST
�a
LOT , ohw— OVERHEAD WIRES
L. 758 P. 195
n/f NOW OR FORMERLY
DISTRIBUTION BOX
1,000 GAL
S83 20'35"E SEPTIC TANK water
jshut off
287.74' 32.1'
25' SIDE BUILDING SETBACK
Lands n/f ` t -; 26.0' undut9 ties A1° REFERENCE.
Y! 9
19 _
Christopher 9.a A
- 1Dher M Bartley ///// ANGLE � 14.2 ? 1) MAP OF A SUBDIVISION OF LAND MADE FOR FOOTHILLS BUILDERS LLC
& Jammie M. Bartley W shed IRON ¢I - DATED 10/03/14, PREPARED BY BOLSTER AND ASSOCIATES PROFESSIONAL
LAND SURVEYORS.
L. 3124 P. 180 �, ,`j' z ,o
LOT 2 ABSORPTION %%%' c7
+ 00z TRENCHES
�. :r
O Ir) N 93 ® so' E .
r4 NOTES:
m 77.2 ! rn 1 BASE MAP PREPARED FROM A JULY 17 FIELD SURVEY.
O 57.5° y;.''' / catch c Cwa,
Z= 861 ACRES
%iffr% l = basins )
• water
wr f Vii% shut off [[ -
f y,�ingl®rs",tory %1//,r � � 2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1. 4 �!
o yr'ilii>fTa s' //
%I f
fr j 3) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT
= Y f/ 1 OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS
25' SIDE BUILDING SE41 3' OR RESTRIC11ONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT W
1BgcK ^ WOULD DISCLOSE. fy
Lands n/f 37.1'
Douglas H Olds 287gq� ao' , hydrant 4) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE
L. 1004 P. 196 , C14y -- REGARDING DEVELOPMENT OF LAND.
N8320'35-W �+
' 5) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND
SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE
NEW YORK STATE EDUCATION LAW.
v
o
LOT
6) ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE
L®1 ;.a< -;,;: t e LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.
RL
° 7) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM
Qr
: ........ ..... r�t•;, ,. :. _ �-� .r;.,. _
SURFACE LOCATIONS AND MEASUREMENTS OBTAINED FROM A FIELD SURVEY.
3 ,�� , THERE MAY BE OTHER UTILITIES WHICH THE EXISTENCE OF ARE NOT KNOWN. SIZE,
y�1✓;, J �/ r_,,__. ` TYPE AND LOCATION OF ALL UTILITIES AND STRUCTURES MUST BE VERIFIED BY
PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR
U _ �j
q g _ TO ANY EXCAVATION.
OCT 0
G N aF GUEENSSURY PLOT PLAN MADE FOR
gUyLpiNG&CODES -
FOOTHILLS BUILDERS LLC
S NACE E N
Town of QueensburyCounty y of Warren State of New York
10/03/2017
3
, Hudson FaIT__v, New York 1'839_ 342 Main Street .,..
Russell E. Howard, PLS N.Y.S. Lic. No. 50540 Date: 07/13/17 Sheet 01 of 01
`_ _ Date Sealed: Scale: 1 inch = 50 feet Revised: Drawing #:13074L2F