Loading...
RC-000215-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 - Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000215-2017 Date Issued: Wednesday, September 13, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000215-2017 has been completed. Tax Map Number: 308.12-1-34 Location: 108 BURNT HILLS DR Owner: Michaels Group Homes,LLC Applicant: Michaels Group Homes,LLC This structure may be occupied as a: Single Family Dwelling w/FP 2543 s.f. Garage 516 s.f. By Order of Town Board TOWN OF QUEENSBURY/j Issuance of this Certificate of Occupancy DOES NOT relieve the (0 )0; /J 4 t property owner of the responsibility for compliance with Site Plan, {� Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000215-2017 Tax Map No: 308.12-1-34 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 108 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $250,000.00 Owner Address: 10 Blacksmith DR Total Value $250,000.00 Malta,NY 12020 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 10 Blacksmith DR Malta,NY 12020 Plans&Specifications Single Family Dwelling w/FP 2543 s.f. Garage 516 s.f. $1,486.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,May 23,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury beforjuthecx imtioon date.Dated at the Town o ueens //Tue d ay 23,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: 412-7111 Permit No. Tax Map ID Permit Fee 1036 p, Db Zone Historic? _Yes No Rec Fee 'TS� Subdivision Name Buwjrr i 4tD F_[LPe—%C- Lot# Site PjaR4 11nvoi.a_ division# Project Location 1Csa ?;kj L-t PILL s. 1]r�= TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) MLCktu�aSrzn CI L L L Address 1 O 3tA 6IA th+ � --� MSL—t'P. , IDLY 1 ZO ZO Phone/Email Sk$ V=A C% X311 Applicant I;f-Vte_r As p t3t1.1.= Q 2 Address LS mar Phone/Email Contractor saunc A s � 3UILDfNG 8 CNSBuRY Address Phone/Email Contact Person for Building&Codes Compliance: -110 4`1' WC"-'-f Jo Phone 12)51 314 4 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1"floor sf 2,d floor sf Total sf Height Single Family X 1,IIoSc ,3v0 2,S4t-, Two-Family Multi-Family (#of units_) Townhouse Business Office Retail-Mercantile L Factory-Industrial Attached Garage (1,02 3, 4+) K Stto Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Sl ociLE FY_% _k%U_e 12eS1 O�0#0(.8 Source of Heat(circle one) a Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys Are there structures not shown on plot plan? 110 Are there easements on the property? KO Site Information: a. Dimensions or acreage of lot 1 . 75- b. . 75- b. Is this a comer lot? _Yes No c. Will the grade be changed as a result of construction _Yes _�No d. Public water or Private well (circle one) u he Private e. Sewer or Private Septic System(circle one) Sewer QnLvate Value of all work to be performed(labor or materials) $ GSb� oo b DECLARATION.- 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: / PRINT NAME: �/ , �'�+o�7 � Z.�C�.�s cis DATE: F ! SIGNATURE: �r] v ' Z DATE: For office use only Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Onlv Received DATE: 412-1)1-7 Tax Map ID TAx MAP ID: Permit No. ZONE: Permit Fee APPLICANT 1`�11CA.t6�1,� (jtzckh- 1-1[J"es, L.L-C PHONE/E-MAIL St$ .�gq .(c311 ADDRESS 10 DeAQ ' b4A-k-TDk' 1-?cizo INSTALLER/ CH bTGl.6S Pet�Nf A.IV E1CC.ItN/kT111fy PHONE/E-MAIL 510 . -14-7 . 9'311 BUILDER OWNER M[GF1 p.q,S Cy¢CY.A NC4A%t S ,L_t..C 5th .(69 q •to 3)I ADDRESS fc» r-2"-� 1+ILLS 'ptzlV� CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: 't-CCAV PHONE/E-MAIL cB57 .';,144- RESIDENCE bl44- RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes XNo 1981-1991 Spa or Hot Tub installed _Yes No 1992-Present Li //p %4/+o PARCEL INFORMATION Topography _ZCFlat rolling _Steep slope %Slope Soil Nature Sand Loam Clay I Groundwater At what depth: TOWN OF QUEENSBU Bedrock/Impervious material At what depth: N UILDING ,CODES Domestic Water Supply %Z Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size S pllons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length zoo ft.;Each Trench f o Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: 141144. -,7-.—,4 t--9 w, DATE: r/�// 7 SIGNATURE: DATE: _ Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: .412-71 11 Applicant Name: MXcun,oA0-C- Gttza%.P 4O"4BS,LL-L Telephone No.: 5%0 . 9ig.tp15 t Address to be Inspected low P_'%szlar HILLS Dew= Return Address: 10 stuwcs*.rtk+ Int N4n7a,N�/ % Z020 Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: 2� STEP 1: ( } Preliminary approval D E rC E O M E NEED O Slight Swale D O Deep Swale tiAYF P.. O Level with the road TOWN OF C t,l ENSBURY ( } Level with the top of the paved wing BUIL ptF ^npFS Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24„ ( } 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 FUEL BURNING APPLIANCE & Office Use Only CHIMNEY APPLICATION Permit#: ar Permit Fee:$ Town of(Liccn.rbun 742 Bay Road, Queensbury, NY 12804 Invoice:#: P: 518-761-8256 www.gueensbury.net Project Location: /o 8 B,jyt f H i �IS �c . Tax Map ID#: II Room of Install: 11<1— Planned Install Date: **ONE APPLICATION PER APPLIANCE** IE IE 9 VJ IE I 0 4 2�i7 CONTACT INFORMATION: C TOWN OF QUEENSBURY • Applicant: I / BUILDING& CODES Name(s): �l� "I C'4 Mailing Address, C/S/Z: by ,Q/a.CN sem, l l 17a/ Cell Phone: ( s7- ) X157— 4f Land Line: Q Email: • Primary Owner(s): Name(s): Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: • Installer/Builder: Business Name: Llr Contact Name(s): Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: Contact Person for Building & Code Compliance: /g(», /� �75 Cto CeII Phone: (S ) 8rs-7- I/ 'f q Land Line: ( ) Email: i//bC.gscio Q mc�4. ch Gt-ov(p_ CQ '^� Fuel Burning Appliance & Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _ Fireplace Insert x! Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) V Fireplace, factory built** ("Manufacturer's name: Model #: SL 5 D ) SOURCE OF HEAT: Wood _ Coal Pellet Gas CHIMNEY INFORMATION: Masonry (require plans to be submitted): block brick stone Flue: the _steel size, in inches _Material*: _double-wall _triple-wall insulated (*Manufacturer's name: Model #: ) ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces &chimneys require plans to be submitted. 4. Twenty-four (24) hour notification is required for inspections. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above:; PRINT NAME: , C� ' ' (4')C�u SIGNATURE: Z9 Z DATE: Fuel Burning Appliance &Chimney Application Revised March 2017 308.12-1-34 RC-000215-2017 Michaels Group Homes, LLC 108 Burnt Hills Drive SFD w/FP 2543 s.f., Garage 516 s.f. 108 Burnt Hills HVAC Load Calculations for The Michaels Group I yftwoRr ' I I HVACft;ySID�NTIAI. H�fAG LOADS ECEOWE t"QY 0 4 2017 D TOWN OF QUEENSBURY BUILDING& CODES I Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Thursday,April 27,2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Resident.... .Li ght Commercial HVAC Loads Elite SoHware Development,Inc. Appolo Heatinglnc. - 108 Bumt Hills Schenectady NY 12306 Pe9e2 Project Report _ General Project Information Project Title: 108 Burnt Hills Designed By: The Michaels Group Project Dale: Monday,April 24, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design_oata Reference City: Schenectady, New York Building Orientation: Front door faces Northeast Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry But Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 1,336 CFM Per Square ft.: 0.352 Square ft. of Room Area: 3,792 Square It. Per Ton: 1,368 Volume(ft')of Cond. Space: 31,703 Building Loads Total Heating Required Including Ventilation Air: 74,037 Btuh 74.037 MBH Total Sensible Gain: 28,986 Btuh 87 % Total Latent Gain: 4,278 Btuh 13 % Total Cooling Required Including Ventilation Air: 33,264 Btuh 2.77 Tons(Based On Sensible+ Latent) :Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i I i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\108 Burnt Hilis.rh9 Thursday,April 27,2017, 9:43 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 108 Burnt Hills Schenectady NY 12306 ��1 ___ Pa e3. Miscellaneous Report System 1 _ Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum_ DryBulb __ Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 [Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 In.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.560 AC/hr 0.290 AC/hr 296 CFM 153 CFM Infiltration Actual: 0.560 AC/hr 0.290 AC/hr Above Grade Volume: X 31.702 Cu.ft. X 31.702 Cu.ft. 17,753 Cu.ft./hr 9,194 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 296 CFM 153 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration&Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.560 AC/hr(296 CFM), Construction: Semi-Loose Summer Infiltration Specified: 0.290 AC/hr(153 CFM), Construction: Semi-Loose i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\108 Burnt Hills.rh9 Thursday,April 27, 2017, 9:43 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 106 Burnt Hills Scheneclady NY 12306 Page 4 Load Preview Report Net R? Sen Lal Net Sen Sys Sys Sys Duct ScopeAct Ton Ron Area Galn Gain Gein Loss CFM CFM CFM Size Bulking 2.77 1,368 3.792 28,986 4278 33,264 74,037 975 1,336 1,336 System 1 2.77 1,368 3,792 28,986 4,278 33,264 74,037 975 1,336 1,336 12x79 Zone 1 3,792 28,986 4278 33,264 74,037 975 1,336 1,336 12x19 1-Basement 1,156 3,046 758 3,804 13,724 181 140 140 2-5 2-Dining 154 2,098 246 2,344 5,962 78 97 97 1-6 3.161chen 126 995 82 1,077 2A36 27 46 46 114 4-Great Room 391 2,888 293 3,181 8,033 108 133 133 2-5 5-Powder Room 40 690 45 735 1,045 14 32 32 1-4 6.1-fomeoffos 185 1,828 185 2,013 4,490 59 84 84 1-5 7-Mud Room 74 1,037 119 1,156 2,408 32 48 48 1-4 8-Foyer 122 1,044 175 1219 3,377 44 48 48 111 9-Master Bedroom 274 2,859 826 3,685 8,118 81 132 132 2-5 10-Master Baih 94 826 42 868 1,591 21 38 38 1.4 11-BedmDm3 188 2,370 472 2,842 4,602 60 109 109 14 12-WIC 80 626 44 670 1,338 18 29 29 1-4 13-Loft 81 551 0 551 764 10 25 25 1-4 14S1lting 195 1,438 97 1,535 3,400 45 66 66 1-5 15-Bonus 249 2,547 287 2,834 6,745 89 117 117 2-4 16-WIC 2 53 629 88 717 1,847 22 29 29 1-4 17-WIC3 53 478 0 478 495 7 22 22 1-4 18-Bedmom2 188 2,150 467 2,617 4561 60 99 99 1-6 19-Ba912 90 885 52 937 1,713 23 41 41 111 i i I I I li i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\108 Burnt Hills.rh9 Thursday,April 27, 2017, 9:43 AM . I I i Rhvac-Residen0al&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 106 Burnt Hills Scheneclad ,NY 12306 Page 5 Duct Size Preview _ Room or Minimum Maximum Rough. Design SP Duct Duct Hlg Cy Acl. Duct Duct Name $0U Velocity vetociy FaUar LA 00 Loss Velocity Length Flow fbw Flow Size System 1 Supply Runouts Zone 1 i-Basement Built-In 450 750 OA7 0.1 514.8 till "140: 140 2-5 2-Dining Built-In 450 750 OAi 0.1 492.4 78 -9Y 97 15 Milchen Built-In 450 750 0.01 0.1 525.5 27:'- 46',. 46 1-4 4-GreatRwrn Built-in 450 750 0.01 0.1 488 1061 133: 133 2-5 5?order Room Bull-In 450 750 0.01 0.1 364.5 14 32I 32 1-4 6-Home Office Built-In 450 750 0.01 0.1 617.9 59 84 84 1-5 7-Mud Room Built-In 450 750 0.01 0.1 547.5 32 -48 48 1-4 8-Foyer Built-in 450 750 OAt 0.1 551.3 44 481 48 1-4 9-Master Bedmom Built-in 450 750 0.01 0.1 483 81 132 132 2-5 ! I 10-Master Bath Built-In 450 750 0.01 0.1 436.2 21 36 38 1-4 11-Bedmom3 Built-In 450 750 0.01 0.1 556.1 60! 'log" 109 1-6 12-WIC Built-in 450 750 0.01 0.1 330.5 18 291 29 1-4 13-Loft Built-In 450 750 0.01 0.1 291.2 10:.. 25 25 1-4 14-Sitting Built-In 450 750 0.01 0.1 486.1 45 %.66 66 15 115-Bonus Built-In 450 750 0.01 0.1 872.5 89 -117. 117 2-4 16-WIC2 Built-In 450 750 0.01 0.1 332.1 22(. - 29 29 1-4 17-WIC 3 BuiMin 450 750 0.01 0.1 252.4 7! 22" 22 1-4 18-Bedroom 2 Built-in 450 750 0.01 0.1 504.6 60 99 99 1-6 1&Bath 2 Built-in 450 750 0.01 0.1 467.6 23 41 41 15 Omer Ducts In System 1 Supply Main Tmnk Built-In 650 900 0.003 0.1 843.6 975 1,336, 1,336 12x19 Summary System 1 - Heating Flow: 975 j Cooling Flow. 1336 I i I I I I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\106 Burnt Hills.rh9 Thursday,April 27, 2017, 9:43 AM Rhvac-Residential&Light Commercial HVAC Loads Elite SoHware Development,Inc. • Appolo Heating Inc. � 108 Bumt Hills Schenectady NY 12306 _Page 6 Total Building Summary Loads t Component Area Sen Lat Sen Total Description Quan Loss _Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 345.6 7,393 0 4,745 4,745 Pella Slider: Door-Slider 21 435 0 145 145 Fire Rated: Door-Fire Rated 21 246 0 82 82 Front Door TMG: Door-TMG Entry 21 246 0 82 82 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1000 6,278 0 1,684 1,684 cavity, no board insulation, siding finish,wood studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2654.9 11,907 0 2,121 2,121 cavity, no board insulation, siding finish,wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1698 3,046 0 2,073 2,073 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal,Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1156 1,994 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 2338.3 17,878 0 3,110 3,110 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 297.9 2,461 0 429 429 on exposed walls, sealed or vented space, passive, no floor Insulation,tile or_viny_I _ Subtotals for structure: 51,884 0 14,471 14,471 People: 4 1,200 1,600 2,600 Equipment: 0 0 0 Lighting: 3150 10,742 10,742 Ductwork: 0 0 0 0 Infiltration:Winter CFM:296,Summer CFM: 153 22,153 3,078 1,995 5,073 Ventilation:Winter CFM:0,Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 179 179 Total Building Load Totals: 74,037 4,278 28,986 33,264 Check Figures Total Building Supply CFM: 1,336 CFM Per Square ft.: 0.352 Square ft. of Room Area: 3,792 Square ft. Per Ton: 1,368 Volume(W)of Cond. Space: 31,703 rB-ifilding Loads Total Heating Required Including Ventilation Air: 74,037 Btuh 74.037 MBH Total Sensible Gain: 28,986 Btuh 87 % Total Latent Gain: 4,278 Btuh 13 % Total Cooling Required Including Ventilation Air: 33,264 Btuh 2.77 Tons(Based On Sensible+ Latent) Notes ---- -- - - --- Rhvac is an ACCA approved Manual J and Manual D computer program. � Calculations are performed per ACCA Manual J 13th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\108 Burnt HIIIs,rh9 Thursday,April 27, 2017, 9:43 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Dave lopmenq Inc. Appolo Healing Ina 108 Bunt Hills Sehaneclady,NY 12306 a 27 System 1 Room Load Summary Htg Min - Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No-Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM --Zone 1--- 1 Basement 1,156 13,724 161 2-5 515 3,046 758 140 140 2 Dining 154 5,962 78 1-6 492 2,098 246 97 97 3 Kitchen 126 2,036 27 1.4 525 995 82 46 46 4 Great Room 391 8,033 106 2-5 488 2,888 293 133 133 5 Powder Room 40 1,045 14 1-4 364 690 45 32 32 6 Home Office 185 4,490 59 1-5 618 1,828 185 84 84 7 Mud Room 74 2,408 32 1-4 546 1,037 119 48 48 8 Foyer 122 3,377 44 1.4 551 1,044 175 48 48 9 Master Bedroom 274 6,116 81 2-5 483 2,859 826 132 132 10 Master Bath 94 1,591 21 1-4 436 826 42 38 38 11 Bedroom 3 188 4,592 60 1-6 556 2,370 472 109 109 12 WIC 80 1,338 18 1-4 330 626 44 29 29 13 Loft 81 764 10 1-4 291 551 0 25 25 14 Sitting 195 3,400 45 1-5 486 1,438 97 66 66 15 Bonus 249 6,745 89 2-4 673 2,547 287 117 117 16 WIC 2 53 1,647 22 1-4 332 629 88 29 29 17 WIC 3 53 495 7 1.4 252 478 0 22 22 18 Bedroom 2 188 4,561 60 1.6 505 2,150 467 99 99 _ 19 Bath 2 90 1,713 __. 23 1.4 468 885 52 _ 41_ 41 System I total 3,792 74,037 .- 975 28,986 4,278 1,336 1,336 System 1 Main Trunk Size: 12x19 in. Velocity: 844 ft./min Loss per 100 ft.: 0.096 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.77 87%/13% 28,986 4,278 33,264 Actual: 3.46 75%/25% 31,125 10,375 41,500 Equipment Data - Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH090XP48C-' 13ACXN042-230`* Indoor Model: C35-48C+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 14 SEER Sound: 0 0 Capacity: 85,000 Btuh 41,500 Btuh Sensible Capacity: n/a 31,125 Btuh Latent Capacity: n/a 10,375 Btuh AHRI Reference No.: n/a 8267124 i I CAUsers\nickMDocuments\Elite Software\Rhvac 9 ProjectWUB Burnt Hills.rh9 Thursday,April 27, 2017, 9:43 AM REScheck Software Version 4.6.2 Compliance Certificate Project The Parker 308.12-1-34 RC-000215-2017 Energy Code: 20151ECC Michaels Group Homes, LLC Location: Warren County, New York 108 Burnt Hills Drive Construction Type: Single-family Project Type: New Construction SFD W/FP 2543 S.f., Garage 516 s.f. Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area: 2,543 ft2 Glazing Area 12% Climate Zone: 6 (8499 HDD) Permit Date: 20 April, 2017 Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 108 Burnt Hills Drive The Michaels Group, LLC Queensbury, NY 10 Blacksmith Drive Malta, NY 12020 Compliance:Passes using performance alternative Compliance: 1.6%Better Than Code Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Foundation Wall:Solid Concrete or Masonry 274 0.0 19.0 0.039 10 Orientation: Left side Wall height: 7.6' Depth below grade: 6.6' Insulation depth:7.6' Ix Std Basement Window:Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC:0.45 Orientation: Left side 1x 5030 Sliding Window:Wood Frame:Double Pane with Low-E 15 0.300 5 SHGC: 0.45 Orientation: Left side r� 9� r,� Foundation Wall:Solid Concrete or Masonry LS C E E. D 175 0.0 19.0 0.039 7 Orientation: Front Wall height: 7.6' I Depth below grade: 6.6' 144V U Y 2t0ll Insulation depth:7.6' Foundation Wall:Solid Concrete or Masonry 342 0.0 19.0 0.039 13 Orientation: Back TOWN OF QUEENSBUPY Wall height: 7.6' BUILDING&CODES Depth below grade: 6.6' Insulation depth: 7.6' Foundation Wall:Solid Concrete or Masonry 429 0.0 19.0 0.039 17 Orientation: Right side Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Project Title:The Parker Report date: 0421/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 1 of 10 Gross Area Cavity Cont. Assembly or U-Factor UA Ix Std Basement Window:Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.45 Orientation: Right side 1st Floor Walls: Wood Frame,24"o .c. 207 21.0 0.0 0.056 7 Orientation: Front Mud#20: Solid 19 0.170 3 Orientation: Front Foyer#1:Solid 21 0.170 4 Orientation: Front 2x Home Office(0): Wood Frame:Double Pane with Low-E 36 0.300 11 SHGC: 0.45 Orientation: Front 1st Floor Walls:Wood Frame, 24" o.c. 405 21.0 0.0 0.056 17 Orientation: Back 2x Great Room (E):Wood Frame:Double Pane with Low-E 29 0.300 9 SHGC: 0.45 Orientation: Back 1x Great Room (R):Wood Frame:Double Pane with Low-E 27 0.300 8 SHGC: 0.45 Orientation: Back 2x Dining (C): Wood Frame:Double Pane with Low-E 21 0.300 6 SHGC: 0.45 Orientation: Back Ix Dining (H):Wood Frame:Double Pane with Low-E 33 0.300 10 SHGC: 0.45 Orientation: Back 1st Floor Walls:Wood Frame,24"o.c. 324 21.0 0.0 0.056 17 Orientation: Left side Ix Powder(AM): Wood Frame:Double Pane with Low-E 7 0.300 2 SHGC: 0.45 Orientation: Left side #19 Dining: Glass 19 0.290 6 SHGC: 0.20 Orientation: Right side 1st Floor Walls:Wood Frame,24"o .c. 509 21.0 0.0 0.056 28 Orientation: Right side 1x Mud (ACJ: Wood Frame:Double Pane with Low-E 4 0.300 1 SHGC: 0.45 Orientation: Right side 2nd Floor Walls:Wood Frame, 24" o.c. 424 21.0 0.0 0.056 19 Orientation: Front 2x Bed #3 (AT):Wood Frame:Double Pane with Low-E 32 0.300 10 SHGC: 0.45 Orientation: Front 1x Hall (AT):Wood Frame:Double Pane with Low-E 16 0.300 5 SHGC: 0.45 Orientation: Front 2x Bonus(B):Wood Frame:Double Pane with Low-E 19 0.300 6 SHGC: 0.45 Orientation: Front 1x Bonus(K):Wood Frame:Double Pane with Low-E 17 0.300 5 SHGC: 0.45 Orientation: Front 2nd Floor Walls:Wood Frame, 24" o.c. 264 21.0 0.0 0.056 11 Orientation: Back 1x Master Bed (G): Wood Frame:Double Pane with Law-E 32 0.300 10 SHGC: 0.45 Orientation: Back 2x Bed #2 (AT):Wood Frame:Double Pane with Low-E 32 0.300 10 SHGC: 0.45 Orientation: Back Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 2 of 10 Assembly Gross r Area Cavity Cont. U-Factor UA 2nd Floor Walls:Wood Frame, 24"o.c. 288 21.0 0.0 0.056 16 Orientation: Left side 1x Master Bath (X): Wood Frame:Double Pane with Low-E 4 0.300 1 SHGC: 0.45 Orientation: Left side 2nd Floor Walls:Wood Frame, 24" o.c. 448 21.0 0.0 0.056 25 Orientation: Right side 1x Main Bath (AM):Wood Frame:Double Pane with Low-E 7 0.300 2 SHGC: 0.45 Orientation: Right side Ceiling: Raised or Energy Truss 1,554 38.0 0.0 0.025 39 Cantilever:All-Wood Joist/rruss:Over Unconditioned Space 40 30.0 0.0 0.033 1 Floor Above Garage:All-Wood joist/Truss:Over Unconditioned Space 398 30.0 0.0 0.033 13 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title dd Signa ,JprjL 2J C) 1<µ,A9'd V �0 068316 Vw� A�0 .11 �P Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 3 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the 0 building envelope.Thermal [-]Not Observable envelope represented on [-]Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7energy code compliance for ❑Not Observable [PR3]1 lighting and mechanical systems. Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 40317 sized per ACCA Manual S based Btu/hr— Btu/hr— ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: .$ Manual J or other methods Btu/hrBtu/hr ❑Not Observable approved by the code official. _ _ ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 1 2 1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 4 of 10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies (F0411 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used,verification ❑No[Observable may need to occur during Insulation Inspection.Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies (FO511 insulation installed per ❑Does Not 0 manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ❑Does Not table for values. `10 distance from top of wall. (_]Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F011]l to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in,below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F01212 controls installed. ❑Does Not - ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 5 of 10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Re .ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRI]' ❑Not Observable `a ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U-_ ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not 0 AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]1 sealed at housing/interior finish ❑Does Not and labeled to indicate 152.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 405.2 All ducts in unconditioned spaces R-_ R-_ ❑Complies [FR25]1 or outside the building envelope ❑Does Not are insulated to >_R-6. ❑Not Observable ❑Not Applicable 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not Q) ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R-_ R-_ ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not ,0 below 55 QF are insulated to aR- []Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not 3 ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [F 1911 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2'. Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 6 of 10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not U, provided. j❑Not Observable ;❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel ❑Not Observable a ❑Not Applicable 303.2, Floor insulation installed per ;❑Complies 402.2.7 manufacturer's instructions and EDoes Not [IN211 in substantial contact with the underside of the subfloor, or floor !❑Not Observable framing cavity insulation is in !❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1A of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN311 exterior, the exterior insulation Mass E] Mass ❑Not Observable requirement applies(FR1O), ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2.1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Parker Report date: 0421/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 4021.2• ❑ Steel ❑ Steel ❑ 402.2.6 Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per .i❑complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every ❑ 300 ft'. INot Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F]22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ❑Complies [F117]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F1411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa.For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft' ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handier enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [924]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F1911 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [Flll]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 403.6.1. All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Nat Observable and airflow limits. ❑Nat Applicable X1 1 1 High l 2 Medium Impact( i r 2) 3 11 Low Impact(Tier 3) Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions A Re .ID Value Value Complies? Comments/Assumptions 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]' have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems []Complies [F[29]2 comply with IEEE 515.1 or UL []Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that []Complies [F130]2 have recirculation pumps that [-]Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [F13 1]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent []Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. []Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI2313 no continuous pilot light. ❑Does Not Q. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]1 ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 9 of 10 section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 303.3 Manufacturer manuals for '.❑Complies IFI18]3 mechanical and water heating El Does Not systems have been provided. .❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Parker Report date: 04/21/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\108 Burnt Hills Drive.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate In! R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 0.45 Door 0.17 0.20 Heating&Cooling Equipment Efficiency Heating System• Cooling System: Water Heater: Name: Date: Comments C-349 N 57051 '06" E W 556.83' 1 , x r W U Ido? Ar o o �1 F- 1° LOT 9 P . o h- w iK 76442. 8 Sq. Feet I v a } n :D 1 . 75 Acres Co _ U> LLJ w W LU �. � o N P w < 2 \ \ 436.09' n } S 57051 ' 06" W \ _^ ysq U3 W zo © W°U \ 1= = LU 0 7 308.12-1-34 RC-000215-2017 °� Homes, LLC — ! om Michaels Group I 108 Burnt Hills Drive e 516 s.f. ' l © ~ \ SFD w/FP 2543 s.f., Garag a q