Loading...
RC-000097-2017 TOWN OF QUEENSBUR.Y 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000097-2017 Date Issued: Tuesday, July 3, 2018 This is to certify that work requested to be done as shown by Permit Number RC"000097-2017 has been completed. Tax Map Number: 290.4-94 Location: 146 Chestnut Ridge RD Owner: Pam Smith,Michael Smith Applicant: BMS Builders,LLC This structure may be occupied as a: SFD w/2 FPs(great nn&basement)2,706 sq. ft. Garage 980 sq. ft. By Order of Town Board Deep Hole Perc Test scheduled 3/17/2017 TOWN OF QUEENSBURY Cross Ref. Site Plan Review -2017 required prior to any development within Jane B.Lowell Subdivision SB 4-2008 Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the 7- Planning Board or Zoning Board of Appeals. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000097-2017 Tax Map No: 290.4-94 Permission is hereby granted to: BMS Builders,LLC For properly located at: 146 Chestnut Ridge RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Pam Smith Single Family-New $600,000.00 Owner Address: 37 SWEET RD Total Value $600,000.00 Queensbury,NY 12804 Contractor or Builders Name/Address Electrical Inspection Agency BMS Builders,LLC 67 County Route 41 Hudson Falls,NY 12839 Plans&Specifications SFD w/2 FPs(great rm&basement)2,706 sq.R. Garage 980 sq.R. Deep Hole Pero Test scheduled 3/17/2017 Cross Ref. Site Plan Review_-2017 required prior to any development within Jane B.Lowell Subdivision SB 4-2008 $1,838.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,May 26,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury beforejtheekatioon date.Dated at the Town o ueensb /J Fri 26,2017 SIGNED BY: V for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only !wr /5,a Date: ` / 3�\� Permit No. R�, /pw e 1l-Q-01-/—7 Tax Map ID Za'b - � - 1y Permit Fee W,20 t -;k- ) Zone SY- \ k Historic? _Yes X_No Rec Fee Subdivision Name Lot# _ Site Plan# � ` Subdivision# Project Location ty�sr %L A K�f1v TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplex - apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile h RES Cap Ed@o�o D permit fee(s). Primary Owner(s) � MAR 15 2017 Address �' \ZwNOFQUEENSBU Phone/Email COMMUNITY NT Applicant Address 1�3 Phone/Email Aks- v73: r- Contractor Address Phone/Email Contact Person for Building& Codes Compliance: Phone TYPE OF CONSTRUCTION ,'Check all that apply New Addition Alteration 1"floor sf 2nd floor sf Total sf Height Single Family Two-Family (� Vk7 L V7o N Multi-Family u (#of units m _� ` a Townhouse `" a o a s Business Office U -0 � Retail-Mercantile o v � m Factory-Industrial r rn o E i2 Attached Garage E c o d 1, 2, 3, 4+) � S aa o pjf L vUI Other o Y ,0 0 lzr C-4 Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If`commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) ;ffa�'75 Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys Are there structures not shown on plot plan? kj O Are there easements on the property? U p Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? _Yes o c. Will the grade be changed as a result of construction _Yes _,& No d. Public water or Private well(circle one) Public Pnva e. Sewer or Private Septic System(circle one) Sewer vate C Value of all work to be performed(labor or materials) $ 3.Sa 1L DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: c )ZZN\ DATE: 13 l7 SIGNATURE: DATE: 17 For office use only Operating Permit Issued: —Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Applicat office Use Only Received DATE: l ( Tax Map ID TAX MAP ID: — (- y C E Q Permit No. D Permit Fee •x ZONE: S - M- 520717 OWNER M � [1 TOWN OFQUEENSB o /E-MAIL go- 3602 num wip, ADDRESS 3� Sw s� INSTALLER/ X11.1 PHONE/E-MAIL 'i%,S 0�ZZ3 BUILDERs �•\ S ,G� �r�LcJQL• CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL BUILDING ADDRESS ISL t� ROOM OF INSTALL: PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: ; Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK _BRICK _STONE Flue TIE STEEL Size in inches Material _DOUBLE WALL _TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ;Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: e DATE: 1 SIGNATURE: W DATE: -4/kO I Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application ` Office Use only Received DATE: 1 ( /� Tax Map ID TAX MAP ID: - - El� 11/) ermit No. ZONE: - v D ermit Fee L MAR 15 1017 OWNER � r "OVA PHO /E-MAIL 80- 3602ADDRESS 3� s � ENP 804 INSTALLER/ PHONE/E-MAIL y\S- �zZ3 BUILDER —t"S v�` s W skQ ' CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL BUILDING ADDRESS VAL 6s�, Cacv.ti, ROOM OF INSTALL: PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) _BLOCK _BRICK _STONE Flue TIE STEEL Size in inches Material _DOUBLE WALL _TRB'LE WALL _INSULATED ** If non-masonry provide manufacturer name: ;Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINTNAME: DATE: S l�- SIGNATURE: DATE: 72 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Deep -f-Wi�-- -t�e6t ja-Fi% �k �7 SEPTIC DISPOSAL APP Office Use Only fZe q7 / i D LS 0 E 12� Received 7 DATE: 1S (� D Tax Map ID TAx MAP ID: 1- MAR I _ 2017 Permit No. ZONE: Z ermitFee /7 � i o�rl �� COMMUNIITY DEVELOPMr APPLICANT 169PHONE/E-MAIL SIS_ 1I6- 4223 ADDRESS 9.1 \ INSTALLER/ PHONE/E-MAIL 'Powj v � a Cowl BUILDER _ OWNER ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed —Yes X-_No 1981-1991 Spa or Hot Tub installed Yes�LCNo 1992-Present PARCEL INFORMATION Topography Flat rolling _Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is_ft) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size _gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requir ents of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: DATE: d17 SIGNATURE: { DATE: a— Town of Queensbury B i ding&Codes Principal Structure Application Revised January 2016 Page 1 Residential Heat Loss and Heat Gain Calculation 3/24/2017 In accordance with ACCA Manual J Report Prepared By: Security Supply Corporation For: MIKE SMITH 146 CHESTNUT RIDGE QUEENSBURY, N.Y. 12804 Design Conditions: GLENS FALLS Indoor: Outdoor: Summer temperature: 68 Summer temperature: 92 Winter temperature: 72 Winter temperature: -15 Relative humidity: 55 Summer grains of moisture: 87 Daily temperature rangeMedium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 4,823.8 sq.ft. 43,823 4,254 48,077 82,453 (4 tons ) First Floor 11,864 816 12,680 18,464 Bathroom--wic 90 sq.ft. 1,856 124 1,980 2,957 Infiltration 151 124 275 955 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 90 sq.ft. 0 0 0 0 -Over conditioned space W Wall 72 sq.ft. 119 0 119 376 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 1,104 0 1,104 719 -Double pane; Wood frame; Clear glass -No inside_ shading; Coating: None(clear glass); No outside shading. S Wall 79.5 sq.ft. 132 0 132 415 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 6 sq.ft. 238 0 238 288 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 90 sq.ft. 112 0 112 204 -Under ventilated attic; R-38 (10 inch); Dark bedroom 2 144 sq.ft. 2,826 177 3,003 3,834 Infiltration 215 177 392 1,365 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 144 sq.ft. 0 0 0 0 -Over conditioned space W Wall 78 sq.ft. 129 0 129 407 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Page 2 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Window 30 sq.ft. 2,208 0 2,208 1,438 -Double pane; Wood frame; Clear glass -No Inside shading; Coating: None (clear glass); No outside shading. N Wall 57 sq.ft. 94 0 94 298 -Wood frame,with sheathing, siding or brick; R-19 51/2 in.; none Ceiling 144 sq.ft. 180 0 180 326 Under ventilated attic; R-38(10 inch); Dark linen 72 sq.ft. 450 35 485 _ 975 Infiltration 43 35 78 273 -_Tightness:Avg.; WinterACH: .7 ; SummerACH: .4_ Floor --- 72 sq.fL 0 0 -- 0 0 -Over conditioned space S Wall 48 sq.ft. 79 0 79 251 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 6 sq.fL 238 0 238 288 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 72 sq.ft 90 0 90 163 -Under ventilated attic; R-38 (10 inch); Dark _ wic 120 sq.ft. 976 89 1,065 2,063 Infiltration 108 89 197 682 -Tightness:Avg.;Winter ACH: .7; SummerACH: .4 Floor 120 sq.ft. 0 0 0 0 -Over conditioned space S Wall 75 sq.ft. 124 0 124 391 -Wood frame,with sheathing_, siding or brick; R-19 51/2 in.; none Window 15 sq.ft. 594 0 594 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 120 sq.ft. 150 0 150 271 -Under ventilated attic; R-38(10 inch); Dark master bedroom 300 sq.ft. 4,096 296 4,392 5,770 Infiltration 359 296 655 2,275 Tightness:Avg.; WinterACH: .7 ; SummerACR A Floor 300 sq.ft. 0 0 0 0 -Over conditioned space SE Wall 80.5 sq.fL 133 0 133 420 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 30 sq.ft. 1,938 0 1,938 1,438 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Window(2) 10 sq.ft. 646 0 646 479 - Double pane; Wood frame; Clear glass Page 3 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) -No inside shading; Coating: None(clear glass); No outside shading. Window(3) 10 sq.ft. 646 0 646 479 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 300 sq.ft. 374 0 374 679 -Under ventilated attic; R-38(10 inch); Dark master bathroom 144 sq.ft. 1,660 95 1,755 2,865 Infiltration 115 95 210 728 -Tightness:Avg.;Winter ACH: .7 ; Summer ACH: .4 Floor 144 sq.ft. 0 0 0 0 -Over conditioned space SW Wall 92 sq.ft. 152 0 152 480 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 16 sq.ft 1,034 0 1,034 767 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. S Wall 108 sq.ft. 179 0 179 564 -Wood frame,with sheathing,siding or brick; R-19 5 1/2 in.; none Ceiling 144 sq.ft. 180 0 180 326 -Under ventilated attic; R-38 (10 inch); Dark First Floor(2) 25,951 2,906 28,857 44,897 Entry Foyer 140 sq.ft. 2,908 207 3,115 3,492 Infiltration 251 207 458 1,592 Tightness:Avg.;Winter ACH: .7_; SummerACH: .4 Floor 140 sq.ft. 0 0 0 0 -Over conditioned space W Wall 55 sq.ft. 91 0 91 287 -Wood frame,with sheathing,siding or brick; R-19 5 1/2 in.; none _ Window 14 sq.ft. 1,030 0 1,030 671 -Double pane; Wood frame; Clear glass c Wj, -No inside shading; Coating: None(clear glass); No outside shading. Glassdoor 21 sq.ft. 1,361 0 1,361 625 -French doors; Double pane; Wood or vinyl frame; Low emittance -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 140 sq.ft. 175 0 175 317 Under ventilated attic; R-38(10 inch); Dark Office 140 sq.ft. 3,497 177 3,674 3,433 Infiltration 215 177 392 1,365 -Tightness:Avg.;Winter ACH: .7; Summer ACH: .4 Miscellaneous 800 0 800 0 Floor 140 sq.ft. 0 0 0 0 -Over conditioned space Page 4 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) W Wall 60 sq.ft. 99 0 99 313 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 30 sq.ft. 2,208 0 2,208 1,438 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 140 sq.ft. 175 0 175 317 -Under ventilated attic; R-38 (10 inch); Dark great room 357 sq.ft. 6,704 1,594 8,298 18,341 Infiltration 817 674 1,491 5,186 -Tightness:Avg.;Winter ACH: .7; SummerACR A People 4 1,200 920 2,120 0 Fireplace 0 0 0 7,331 -Average-glass doors, damper Floor 357 sq.ft. 0 0 0 0 -Over conditioned space S Wall 180 sq.ft. 298 0 298 940 -Wood frame, with sheathing,siding or brick; R-19 5 1/2 in.; none Window 30 sq.ft. 1,188 0 1,188 1,438 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Glassdoor 84 sq.ft. 2,755 0 2,755 2,638 -Sliding glass door, Double pane; Wood or vinyl frame; Low emittance -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 357 sq.ft. 446 0 446 808 -Under ventilated attic; R-38 (10 inch); Dark dining—sitting _ 273 sq.ft. 5,484 532 6,016 9,606 Infiltration 645 532 1,177 4,094 -Tightness:Avg.; WinterACH: .7; SummerACR A Floor 273 sq.ft. 0 0 0 0 -Over conditioned space S Wall 57 sq.ft. 94 0 94 298 Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 30 sq.ft. 1,188 0 1,188 1,438 -Double pane; Wood frame;Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Window(2) 30 sq.ft. 1,188 0 1,188 1,438 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. SW Wall 27 sq.ft. 45 0 45 141 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 969 0 969 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Page 5 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) SE Wall 27 sq.ft. 45 0 45 141 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 969 0 969 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 273 sq.ft. 341 0 341 618 - Under ventilated attic; R-38 (10 inch); Dark Kitchen 217 sq.ft. 3,444 112 3,556 3,557 Infiltration 136 112 248 864 Tightness:Avg.;Winter ACH: .7 ; SummerACR A Miscellaneous 1,400 0 1,400 0 Floor 216.8 sq.ft. 0 0 0 0 -Over conditioned space SE Wall 95.8 sq.ft. 159 0 159 500 -Wood frame, with sheathing,siding or brick; R-19 5 1/2 in.; none Window 19 sq.ft. 1,227 0 1,227 911 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. E Wall 151.5 sq.ft. 251 0 251 791 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 217 sq.ft. 271 0 271 491 -Under ventilated attic; R-38 (10 inch); Dark pantry 70 sq.ft. 1,433 89 1,522 1,982 Infiltration 108 89 197 682 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 70 sq.fL 0 0 0 0 -Over conditioned space E Wall 27 sq.ft. 45 0 45 141 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 11104 0 1,104 719 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. E Wall(2) 54 sq.ft. 89 0 89 282 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 70 sq.fL 87 0 87 158 -Under ventilated attic; R-38 (10 inch); Dark mud room 70 sq.ft. 524 106 630 1,948 Infiltration 129 106 235 819 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 70 sq.fL 0 0 0 0 -Over conditioned space N Wall 45 sq.ft. 75 0 75 235 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Page 6 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Door 18 sq.ft. 233 0 233 736 -Metal; Polystyrene; No storm Ceiling 70 sq.ft. 87 0 87 158 -Under ventilated attic; R-38 (10 inch); Dark Laundry 90 sq.ft. 1,246 0 1,246 627 Infiltration 0 0 0 0 -Tightness:Avg.;Winter ACH: .7 ; Summer ACH: .4 Miscellaneous 1,000 0 1,000 0 Floor 90 sq.ft. 0 0 0 0 -Over conditioned space _ N Wall 81 sq.ft. 134 0 134 423 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 90 sq.ft. 112 0 112 204 -_Under ventilated attic; R-38 (10 inch); Dark pdr _ —72-sq.ft. 632 89 721 1,768 Infiltration 108 89 197 682 -_Tightness:Avg.; Winter ACH: .7; Summer ACH: .4 Floor 72 sq.ft. 0 0 0 0 -Over conditioned space N Wall 39 sq.ft. 65 0 65 204 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 369 0 369 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 72 sq.ft. 90 0 90 163 Underventilated attic; R-38(10 inch); Dark wic 63 sq.ft. 79 0 79 143 Infiltration 0 0 0 0 -Tightness:Avg.; WinterACH: .7; SummerACH: .4 Floor 63 sq.ft. 0 0 0 0 -_Over conditioned space Ceiling 63 sq.ft 79 0 79 143 -Under ventilated attic; R-38 (10 inch); Dark Basement 6,009 532 6,541_ 19,091 side 1 1,760 sq.ft. 4,606 355 4,961 13,365 Infiltration 430 355 785 2,729 -_Tightness:Avg.; WinterACH: .7 ; SummerACH: .4 Miscellaneous 1,800 0 1,800 0 Floor 1,760 sq.ft. 0 0 0 3,675 -Basement floor,Tor more below grade; Concrete; Not applicable S Wall BelowGr 336 sq.ft. 0 0 0 1,257 -Block or brick, extends over 5'below grade; R-11 3 1/2 in.; 8 or 12 in. Block Page 7 MIKE SMITH 3/24/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Window 30 sq.ft. 1,188 0 1,188 1,438 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Window(2) 30 sq.ft. 1,188 0 1,188 1,438 -Double pane;Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. SW Wall BelowGr 360 sq.ft. 0 0 0 1,347 -Block or brick, extends over 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block N Wall BelowGr 396 sq.ft. 0 0 0 1,481 -Block or brick, extends over 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block side 2 702 sq.ft. 1,403 177 1,580 5,726 Infiltration 215 177 392 1,365 -Tightness:Avg,; WinterACH: .7 ; SummerACH: .4 Floor 702 sq.ft. 0 0 0 1,466 -Basement floor, 2'or more below grade; Concrete; Not applicable S Wall BelowGr 213 sq.ft. 0 0 0 797 -Block or brick, extends over 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block Window 15 sq.ft. 594 0 594 719 - Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. _ ---...----------------- Window(2) 15 sq.ft. 594 0 594 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. E Wail BelowGr 176.3 sq.ft. 0 0 0 660 -Block or brick, extends over 5'below grade; R-11 3 1/2 in.; 8 or 12 in. Block Whole House 4,823.8 sq.ft. 43,823 4,254 48,077 82,453 (4 tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load oetwatione are estimates only,adueI loads may vay due la weather and oonabuclion diHerenros. Heat Loss Summary Project#: MIKE SMITH Date: March 21, 2017 Prepared For: SECURITY PLUMBING & HEATING SUPPLY Project Summary Project#: MIKE SMITH Total-Components Load: 53,130 Btu/hr Project Name: MIKE SMITH Total Infiltration Load: 53,612 Btu/hr Location: Total Floor Downward Load: 22,513 Btu/hr CloseDate: Total-Radiant Into Rooms: 106,742 Btu/hr Engineer: Total-Supplemental Load: 0 Btu/hr Design Data Location: (User-Specified Location) Total-Project Heat Loss: 120,991 Btu/hr Outdoor Temperature: -17 OF RFH Glycol Level: 30%Glycol Wind Speed: 12 mph Design Temp. Drop: Multiple Total Area: 5,839 ft' (20 OF for all QuikTrak) Construction Quality: Average Radiant Tubing Volume: 51.9 gallons(US) Volume Water: 36.3 gallons(US) Volume Glycol: 15.6 gallons(US) Heat Loss Data Floorplan 1 Heated Ceiling Radiant Into Ftoor Total Total Room Design Room Area Area Walls Windows Doors Upward Skylights Infiltration Room Downward Radiant Load Temp. Load Drop garage 1,007 1,007 2,200 1,845 9,717 2,117 0 9,771 25,651 7,239 32,890 32,890 10 Units: Heat Loss=Btu/hr,Area=ft',Temperature=T Page 1 of 3 Created using Uponor Advanced Design Suite-7.9.0 Heat Loss Summary Project#: MIKE SMITH Date: March 21, 2017 Prepared For: SECURITY PLUMBING & HEATING SUPPLY Floorplan 2 Heated Ceiling Radiant Into Floor Total Total Room Design Room Area Area Walls Windows Doors Upward Skylights Infiltration Room Downward Radiant Load Temp. Load Drop basement side 1 1,760 1,760 3,766 820 1,722 0 0 16,178 22,485 4,999 27,485 27,485 10 basement side 810 810 1,586 820 0 0 0 6,618 9,025 2,011 11,035 11,035 10 floor plan 3 Heated Ceiling Radiant Into Floor Total Total Room Design Room Area Area Walls Windows Doors Upward Skylights Infiltration Room Downward Radiant Load Temp. Load Drop bath/wic 86 71 499 861 0 181 0 703 2,244 374 2,617 2,617 20 bedroom 144 144 445 1,230 0 303 0 1,177 3,155 526 3,680 3,680 20 linen 72 72 164 246 0 151 0 588 1,150 192 1,341 1,341 20 wic 120 120 254 615 0 252 0 981 2,102 350 2,452 2,452 20 master bedroom 330 330 281 1,968 0 694 0 2,696 5,639 940 6,579 6,579 20 master bath 156 156 656 656 0 328 0 1,275 2,915 486 3,400 3,400 20 Unfts: Heat Loss=91Whr,Area=n',Temperature=-F Page 2 of 3 Created using Uponor Advanced Design Suite-7.9.0 Heat Loss Summary Project#: MIKE SMITH Date: March 21, 2017 Prepared For. SECURITY PLUMBING & HEATING SUPPLY Floorplan 4 Heated Ceiling Radiant Into Floor Total Total Room Design Room Area Area Walls Windows Doors Upward Skylights Infiltration Room Downward Radiant Load Temp. Load Drop foyer 120 120 176 574 861 252 0 981 2,844 474 3,317 3,317 20 office 140 140 195 1,230 0 294 0 1,144 2,864 477 3,341 3,341 20 great room 380 380 305 5,658 0 799 0 4,657 11,419 1,903 13,322 13,322 20 sitting 273 273 527 3,075 0 574 0 2,788 6,965 1,161 8,125 8,125 20 kitchen 221 221 1,101 738 0 465 0 2,257 4,561 760 5,321 5,321 20 mud room 70 70 137 0 861 147 0 572 1,717 286 2,003 2,003 20 laundry 90 90 281 0 0 189 0 735 1,206 201 1,407 1,407 20 pdr 60 60 187 0 0 126 0 490 804 134 938 938 20 Unhs: Heat Loss=Btulhr,Area=1t',Temperature=IF Page 3 of 3 Created using Uponor Advanced Design Suite-7.9.0 T c 1{'�1�11rn1�'�A�l ar® KNIGHT k,� 1'JVA FIRE TUBE BOILER HIGH EFFICIENCY BOILERS&WATER HEATERS Submittal Sheet KHN-Sub-01 KNIGHT FIRE TUBE BOILER JOB NAME LOCATION ENGINEER WHOLESALER CONTRACTOR MODEL NO. TYPE GAS EQUIPMENT TAG NOTES MINUET Q —q— WATER OUTLET _ FLUE GAS CONNECTION 43.3/8' �I HIGH-VOLTAGE 1J18' B ELECTRICAL CONNECTIONS D— LOW-VOLTAGE 19' 0 ELECTRICAL F CONNECTIONS G o WATER INLET 41 — C CONDENSATE 1G' DRAIN 1 ADJUSTABLE r E _r ❑ KIIN055 83 55 95 51 44 6' WP II.1/8' 10.1/7 101/4' 37.1/1' 39,5/8" 31-1/4' 13-1/4' 31/8' I/7 I' T I 160 091111035 85 85 95 19 69 6' wr 11.1/8' 10-1/T 13.1/4r 37.1/Y' 31.5/Y 39.1/4' 13-1/4* 8J/3' 1/T I' T 7 165 Q ANNIIO 11 110 95 109 89 7-3/7 WC 11.1/r 105/8' 145/8' A7/f Sr 39.1/7 If 4-W 1/7 1' T T 170 n AINI55 15.5 155 95 144 135 1.7/8' 9.W 11.1/8' 105/8' 14.5/8' 37.3/4' V 39.1/T M 45/8' 11'r I' 7 7 175 BIINI99 19.9 199.9 95 185 161 7d/T 101/7 II.1/e' 145/8' 15-1/8' 3C 3T 39y4' 14' 4.5X I/7 Id/f 3' 7 195 [] DAMS 985 985 95 964 939 MIT 101/1' 11-1/8' II-5/T 1 S Sr 37 391/4' If 45/8' 1/7 LI/f 3' 7 90S -Wmnanon.uq to AenW.mnum,Wnt.MOV' m-I•W IP ye mdels. A,r KNIGHTµ F/RE JURE f10/L EF FIRING CODES M9 Standard Construction M7 California Code SMART SYSTEMTM FEATURES STANDARD FEATURES )Smart System Digital Operating Control )Access to BMS Settings through Graphic LCD )ENERGY STAR Most Efficient Product Multi.Color Graphic LCD Display w/Navigation Dial, Display )95%DOE AFUE Efficiency •Soft Keys and loch-N-LinkT"USB programming )High-Voltage TerminalStrip )Modulating Burner with up to 10:1 Turndown )Three Boller Setpoint Temperature inputs 110 VAC/60 Hertz/S Phase Power Supply Direct Spark Ignition Plus Domestic Hot Water Prioritization Three Sets of Pump Contacts Low NOx Operation )Built-in Cascading Sequencer for up to B Bolters, >LoW-Voltage Terminal Strip ASME Stainless Steel Heal Exchanger with Cascade Redundancy DHW Recirculation Pump Start/Stop 30 PSI ASME Relief Valve Multiple Size Boiler Cascade 24 VAC Device Relay )Vertical&Horizontal Direct Vent Lead Lag Proving Switch Contacts PVC,CPUC,Polypropylene or SS Venting up to 100 Efficiency Optimization Flow Switch Contacts feet )Smart System Control Front End Loading Capability Alarm on Any Failure Contacts >Outdoor Reset Contra[with Outdoor Air Sensor Runtime Conta cis >Candensate Trap Programmable for Three Reset Temperature Inputs DHW Thermostat Contacts )Other Features )Programmable System Efficiency Optimizers 3 Space Heat Thermostat Contacts Automatic Reset High Limit System Sensor Contacts Boiler Circulating High Pu w/Manual Reset SH Night Setback DHW Tank Sensor Contacts Boller Circulating Pump DHW Nigh[Setback Zero Clearances to Combustible Matelots Anti-CycOutdoor ingAir Cascade Co facts Contacts 11-Year Limited Warranty(See Warranty for Ramp Delay Curve Cascade Contacts Details) Ramp Delay 030 VDC BMS External Control Contact Modulation Factor Control 0.10 VDC Boiler Rate Output Contacts Boost Temperature&Time 0-10 VDC Variable Speed System Pump Signal 5-Year Limited Parts Warranty Input>Four Pump Control OPTIONAL EQUIPMENT System Pump with Parameter for Continuous 0-10 VDC Signal to Control Variable Speed Boller Operation Pomp CON-X.USO Remote Connectivity Boiler Pump with Variable Speed Control Modbus Contacts ❑ Modbus Communication Domestic Hot Water Pump )Time Clock E3 BACnet MSTP Domestic Hot Water Recircula0on )Data Logging E-3 Flow Switch Hours Running,Space Heating DHW tank Hat Water p priority In the n Hours Running,Domestic Hot Water 0 Alan Bell Cula0w/Manual Reset&Test DHW tank piped with zone in the system loop Ignition Attempts C7 Alarm Bell DHW tank piped as a zone in the system with the O Concentric Vent Kit controlled b Last Lockouts O pumps y the SMART SYSTEM >Maintonanca Reminder SMART SYSTEMTX PC Software DHW Modulation Limiting Custom Maintenance Reminder with 0 Condensate Neutralization Kit Separately Adjustable Space Heat/DHW Switching Contractor Contact Information p BMS Gateway to LON or BACnet IP Times Installer Ability to De-activate Service Reminder O Multi-Temperature Loop Control )Building Management System Integration )Low-Water Flow Safety Control&Indication O Sidewall Vent Termination 0-10 VDC Input to Control Modulation or Setpoint )password Security O Wireless Outdoor Sensor 0.10 VDC Modulation Rate Output )Customizable Freeze Protection Parameters LP Gas Conversion Kit 0-10 VDC Input to Enable/Disable Call for Heat wmirt..n uc ® )oonaaaa.simPw�P.aMw ALLJO nR N 615 rznnoue 6;L5 V R.E1)aB9.ePW IF:bE).)aT.)000 HIGX ErrICIENEY BOIIERe&WATEN NEA �©®��I�r'� �M��R � " H IWI.r~PTluletl le U8A SUBMITTAL DATA SHEET SINGLE PIECE STANDARD PSC AIR HANDLER SPLIT-SYSTEM FAN COIL MODELS: AP SERIES JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. PRODUCT DATA FEATURES Cooling Performance RC2-Rigid Case Construction interior endoskeleton for structural support,smooth side,and locks in Insulation. Total Capacity" MBH powder-painted - G30 galvanized steel case provide a coated edge that resists Sensible Capacity* MBH corrosion and rust Creep. Temperature of Air Entering Indoor Coli ^F(DB/WB) MaxAlloyTM Coll - Long life aluminum coils built to deliver lasting performance, Suooly Air Blower Performance efficiency and reliability. Total Supply Air CFM Quality Construction - Structural components are made of Aluminum or G90 Total External Static Pressure IWG galvanized steel to prevent corrosion, Blower Speed Settings Improved Insulation Design - Single piece with no external screws to reduce Motor Rating HP thermal transmission paths to prevent sweating. Foil faced insulation for ease of Power Input Requirement KW cleaning. Electrical Data Thermostatic Expansion Valve-The accessory chatleff style TXV provides easy Power supply / I installation to convert the indoor coil to the required refrigerant that does not require Total Unit Ampacity AMPS brazing to replace or Install.Some models are available with factory Installed TXV. Minimum Wire Size AWG Case Depth-These models have 20.5'casing which provide ease of attic access (Copper conductors) and tight applications. Maximum Overcurrent Device Thermoset Drain Pan -Positive slope for drainage to reduce cause for potential ❑ Fuses (Dual Element) mold or contaminants. ❑ Circuit Breaker(HACR) Factory Sealed-Achieves 2%or less total airflow leakage rate at duct leakage test Unit Weiaht conditions in positive and negative pressure for system airflow verification. Total Unit weight LBS Enhanced Filter Rack-All models have Integrated internal filter racks provided for (Include field-Installed accessories) use with 1"thick standard size filters. Options Electric Heat Kits-6HK series of field installed electric heat kits are available for ❑ Factory Installed TXV installation-friendly and easy service applications. -Shown In Outdoor Unit Technical Guide Blowers-All models use direct-drive,multi-speed PSC motors. FIELD INSTALLED ACCESSORIES CLEARANCES Front 24" ❑ Electric Heaters (#6HK ) Rear 0"^ Capacity(Q Volts) MBH Sides 0^+ Power Input Requirement(Less Blower Motor) KW o Cleawnce allowed with or without Electdc Heater. ❑ Combustible Floor Base (# ) ❑ Thermal Expansion/Check Valve Kit(# ) ® ❑ External Filter Kit(# ) AMERICAN MATCHED OUTDOOR UNIT QUALITY S ® ®r ❑ Model Number (# ) III V- �^'^w WI mown, ❑ Submittal Part Number (# ) C US 5006166-USD-"216 DIMENSIONS & DUCT CONNECTION DIMENSIONS IF FRIGERANT CONNECTIONS DRAIN CONNECTIONS TOP OUTLET BLOWERFOR UPFLOWAPPLICATIONS �\ DIMENSIONS COMPARTMENT 12 3liB \`.� ECOILpCOMPARTMoSERVICE DISCONNECT PANEL 7-11 18-W D iFILTERACCESS BOTTOM INLET \I / DIMENSIONS �21-7H 8' DIMENSIONS Dimensional Wiring Knockouts2 Refrigerant Connections Models A B F G Line Size C D E Control Height Width Power(Conduit) (Conduit) Liquid Vapor AP186X21 41 17-1/2 12-7/8 14-1/4 16-1/2 AP24BX21 41 17-1/2 12-718 14-1/4 16-1/2 AP30BX21 47-1/2 17-1/2 19-112 14-1/4 16-1/2 3/4 AP36BX21 47-1/2 17-1/2 19-1/2 14-1/4 16-1/2 AP36CX21 51-1/2 21 22.5/8 173/4 20 718(1/2) AP37CX21 51-1/2 21 1 22-5/8 1 17-3/4 20 1-3/8(1) 7/8(112) 318 AP42CX21 51-1/2 21 22.5/8 17-3/4 20 1-23/32(1-1/4) AP48CX21 51-1/2 21 22-5/8 17-314 20 AP48DX21 55-1/2 24-1/2 26.518 21-1/4 23-1/2 7/8 AP60CX21 553/4 21 26-7/8 17-3f4 20 AP60DX21 55.1/2 24-1/2 26-5/8 21-1/4 23-1/2 1. All dimensions are In Inches. 2. Knockout size(conduit size in parentheses). Subject to change without notice.Published in U.S.A. 5006166-USD-C-0216 Copyright®2016 by Johnson Controls,Inc.All rights reserved. Supersedes:5006166-USD43-0915 York International Corp. 5005 York Drive Norman,OK 73069 SUBMITTAL DATA SHEET LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER — R-410A— 1 PHASE — 1.5 THRU 5 NOMINAL TONS MODELS: TC3618 THRU 60 JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. PRODUCT DATA DIMENSIONS - INCHES Cooling Performance Total Capacity MBH C Outdoor Design Temp °F Electrical Data Power Supply_/_! Compressor Ampacity AMPS Total Unit Ampacity AMPS A Power Input Req KW Minimum Wire Size AWG �Q QO�� Maximum Overcurrent Device ❑ Fuses ❑ Circuit Breaker Unit Weight B Unit Weight LBS \,�� Amssnst Dimensions Refrigerant Connection Unit (Inches) Service Valve Size Model A B C Liquid Vapor TC3B182l(S,H) 23-1/2 24 24 S TC3B2421(S,H) 26-3/4 24 24 3/4 IC3B3021(S,H) 30 24 24 (i us TC3B3621(S,H) 331/4 24 24 3/8 ® TC3B4221263/4 29-1/4 29-1/4 7/8 TC3B4821S1S 30 29-1/4 21,114 TC3136021S 36-1/4 1 29-1/4 29-1/4 7/81 AM E R I CAN *Adapter fitting must be gem Installed for the required 1-0/6'Iine set. QUALII TY Str aaag xFX ISau" All dimensions are In Inches and are subject to change without notice. TY oesienso,sxenI T s ISO 9007 Overall height Is from bottom of base pan to top of fan guard. Asswateo IN WE WA Certified Quality Overall length and wroth include screw heads. Management System Johnson Controls Unitary Products 5146695-BSD-A-0715 FEATURES WARRANTY SUMMARY` • Small Footprint-Minimum footprint for easier handling, Standard 5-Years limited parts warranty. transportation,and installation. Standard 10-Years limited compressor warranty. • Easter Installation-Independent panels provide quick Extended 10-Years limited parts warranty when product Is access for unit setup. Installation time is reduced by easy registered online within 90 days of purchase for replacement power and control wiring access.Options are provided for or closing for new home construction. indoor piston or TXV.The factory installed filter-drier and fac- .Does not appy to R-22 models,3-Phase models,or internal sales. tory charge for a 15-Ft Iineset means less time spent brazing Sae Limited Warranty certificate In Users Information Manuel for details. and charging the system.The small base dimension and reduced unit clearances make for easier retrofits. TYPICAL CLEARANCES • Accessible Information-QR code on unit provides quick access to technical documents and warranty information. The minimum clearances for a typical installation are shown • Durable Finish-The coated steel wlre fan guard,coated below.See the Technical Guide for alternate Installations. external fasteners,and pre-treated G90-equivalent galva- • 10"Clearance Coil Area nized steel chassis components resist corrosion and rust . 48"Overhead Clearance creep.Titanium colored powdercoat paint further protects . 18"Minimum Service Panel Access external panels. • 24"Minimum Unit to Unit Distance • Quality Coils-The high efficiency microchannel aluminum coil Is manufactured using an improved material system pro- MATCHING AIR SIDE EQUIPMENT viding reliable performance and small unit size. • Rugged Coil Protection-Coils are protected from mechan- Model No. ❑ ical damage by a proven stamped steel coil guard design. • Protected Compressor-Compressors are protected Inter- nally by a high pressure relief valve and a temperature sen- sor,and externally by the system high pressure switch.The FIELD INSTALLED ACCESSORIES liquid line filter-drier is factory installed to protect the com- pressor against moisture and debris. Off Cycle Time Delay(S1-27008700124) • Reliable Operation-Ball bearing fan motors provide supe- Standard Low Ambient Control(S1-2LA06700424) rior performance in extreme temperatures. Advanced Low Ambient Control(S1-2LA04701024) • Environmentally Friendly-CFC-free R-41 OA refrigerant Low Pressure Switch Kit(S1-2PS06700524) delivers environmentally friendly performance with zero Compressor Start Assist(S1-2SA067 )' ozone depletion. Compressor Crankcase Heater(S1-025 1' • Top Discharge-Warm air is blown up,away from the struo- Support Feet(S1-HPRKIT- r lure and any landscaping and allows compact location on Anchor Bracket Kit(S7-iHK0401) multi-unit applications. Indoor TXV Kit(S1-1TVM )' • Low Operating Sound Levels-Developed using CFD and FFA tools,the sturdy cabinet and top design provides sound Wall Mount Kit(SI -� performance of 76 dBA or lower.Compatible accessories for Compressor SouundndBlanket(51-010076 )` f •See price pages for accessory Information. further sound reduction are also available. • Better Service Access-Diagonal base valves with open Refer to Technical Guide for detailed specifications on the unit access for low-loss fittings,single panel access to the electri- and its accessories. cal controls,swing out control box for full comer access,and removable fan guard allow easy access for unit mainte- Verify the actual ratings for each specific matchup in the online nance. AHRI directory at wwwahridirecton!ora at the time of bid or • Agency Listed-Safety certified by CSA to UL 1995/CSA sale. It is also recommended to print the rating certificate, if 22.2.Performance certified to ANSI/AHRI Standard 210/240 needed, at the time of bid or sale. in accordance with the Unitary Small Equipment certification program. Subject to change without nodoe.Published in U.S.A. 5146695-BSD-A-0715 Copyright 2015 by Johnson Controls,Inc.All lights reserved. Supersedes:Nothing York Internation Corp. 5005 York Drive Norman,OK 73069 Town of Queensbury D E 6 E 0 V E Thomas R.Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 MAR 1 Home: 518-745-0929 Phone: 518-761-8211 5 1017 Fax: 518-745-4466 TOWN OF David Duell COMMUNITY p EENSBURY Deputy Highway Superintendent EVELOPMENT Home: 518-745-0938 DRIVEWAY PERNIIT Date: 7' 17 Applicant Name: J-e Fern�/ e l de n Telephone No.: 51 - q(5 - 9 ZZ 3 Address to be Inspected )q(pbf u) /21 c U e fr15 b u v Return Address: '1JrZ Ooundf 41 Adson ra/1s, /Qy 12-e3q Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R.Van Ness,Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 THE North Country Office Clea len 375 Bay Road, Queensbury, NY 12804 _ P: (518)812-0513 F: (518)812-2205 COMPANIES www.chazencompanies.com H Engineers Hudson Valley Office (845)454-3980 Environmental Professionals Capital District Office (518)273-0055 Land Surveyors Landscape Architects �^ ®�^ (0 Planners r�f— March 17, 2017 Dave Hatin, Director, Building and Codes I r I Town of Queensbury MAR 2 0 2017 742 Bay Road _ Queensbury, New York 12804 TC.J��'`ilq O rq .c E v �tJr Y BUI,.nie IG &(;LASDES Re: Soil Testing Verification 146 Chestnut Ridge Road Queensbury, NY 12804 91700.08 Dear Mr. Hatin: As requested, Chazen has witnessed onsite soil testing for the above referenced location on March 17, 2017.The purpose of this testing was to investigate subsurface soils conditions for a proposed septic system design.The system is proposed as new construction.The testing was performed by Peter Jensen. Only one soil test was performed to the south east of the site approximately 40'east of Chestnut Ridge Rd. The soil profile consists of the following: 0"-7"Topsoil 7"-44" Medium brown sandy loam with traces of clay. 44"-57" Medium brown sandy loam with clay. Traces of Mottling at 42" Groundwater encountered at 49" Roots encountered 0-12" Boulder and cobbles encountered throughout profile. If you have any questions or require additional information, please do not hesitate to call me at(518) 824-1926. Sincerely, Sean M. Doty, P.E., LEED AP Associate Manager, Municipal Engineering Services Chazen Engineering, Land Surveying&Landscape Architecture Co.,P.C. Chazen Environmental Services, Inc. The Chazen Companies, Inc. 114 - .4 NI._ ANS Weire.„„,, Qbality. Comfort, Satisfaction Thermal Associates . 21 Thomson Ave.Glens Falls, NY 12801 ""2 518.798.5500 Fax 798.5620 AS Builders County Route 11 idson Falls, NY 12839 8-415-9223 sbuilderscyahoo.com' We, Thermal Associates, performed a blower door test at the project at 146 Chestnut Ridge, :ensbury, NY, to determine the air changes per hour, for Northeastern Designs, on April 16, 2018. Testing procedure performed as per ASTM E779. The result of the test is: ( 3,120 CFM50 x 60 Minutes) / ( 66,286 cubic feet ) = 2.824 ACH50 02.4.3.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when 3d air leakage is less than seven air changes per hour(ACH)when tested with a blower door at a ;sure of 33.5 psf(50 Pa) as verified using instruments and procedures specified in ASHRAE/ASTM E779. The test 1 be conducted by a qualified person, who shall demonstrate competence to the satisfaction of the code )rcement official for the conduct of such tests. For the purpose of this section,ACH50 shall mean air changes per r oflnitration into a house as measured with a blower door at 50 pascals of pressure, in accordance with 3RAEIASTM E779. Testing shall occur after rough in and after installation of penetrations of the building envelope, ailing penetrations for utilities,plumbing, electrical,ventilation and combustion appliances. ing testing: xterior windows and doors, fireplace and stove doors shall be closed, not sealed; Pampers shall be closed,but not sealed,including exhaust, intake, :eup air,back draft and flue dampers; iterior doors shall be open; xterior openings for continuous ventilation systems and heat recovery tilators shall be closed and sealed; [eating and cooling system(s) shall be turned off; [VAC ducts shall not be sealed; and upply and return registers shall not be sealed. lam DeVit awer Door Tester iermal Associates 'vw.the rmalassoci ates.com / EFERENCE: UTP NM 19 MAP R tiOF NE4y DEED REFERENCE: 1 . MAP OF TOPOGRAPHY OF MINOR SUBDIVISION OF LANDS OF JANE Q"� cv E. Mo ro,A 1 . "GORDON CYNTNIA HOYT" TO "MICNAEL D SMITH PAMELA A LOWELL BY W.J.KOURKE ASSOCIATES LLC. DATED 10/23/OG AND IS ON co BENACK-SMITH", DATED 00/08/201 G AND RECORDED IN THE WARREN FILE IN THE WARREN COTY CLERI' E. 4, +� v �F 2 4 COUNTY CLERKS OFFICE IN DEED BOOK 5430 AT PAGE 103. S r- 4 LANDS N/F DANIEL J. LOWELL etc+ -"ic .� �O Y 22 �s (� b UUN F�� StjARDNf1ARRlS ��,�` �506�� Ir C E u V E NuBOOK 4/70PAGE8B tA111D �� D / Q TAXI©. 290.-1-93 ./ JUL 0 2 20% TOWN OF QUEENSBURY q---- --- �` 771.93' vI Plf I RIF I RF S 80°43`13"E UTP NMI 8f O sasaalavb�&rN WALL o SIDE SETBACK ---------------- n\ TOTAL J k, w �? L` 20 I PORCH "o (ooco Z } 2ND STORY V O/ /N���� DECK ' G? # q lyl` 1 M J ` AFFRO o _ ...►I LEACN IMATE ®r 100 I rNor vrsiaL°j LAN05 N/F TRl-TOM Df VfLOPMEIV T, INC. I RF STONE WALL _ BDOK 1400 PAGE GO -------'O TAX/D. 290.-1-22.222 0909 N660 39f¢S••N, o I O' MIN- 30' TOTAL SIDE SETBACK 0 390.49` LANDS N/F N 81°24`03" N' ZONING DISTRICT SRi THE MARTIN KALIN REVOCABLE TRUST ' BOOK 5406 PAGE 205 TAX ID #290-1-94 4.703E ACRES TAX/D. 290.-I-22.23 PERMIT#RC972017 ALL RIGHTS RESERVED.COPY OR REPRODUCTION OF THIS PLAN OR ANY PORTION THEREOF IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF THE SURVEYOR. ,SURVEY MAP FOR ABL SURVEYING, PLLC UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED MICNAEL D. SMITH AND MICNAEL E. MONTENA SURVEYOR SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. PAMELA A. BENACK-SMITH 5 AVON PLACE I HEREBY CERTIFY THAT THIS SURVEY MAP IS BASED ON AN ACTUAL FIELD SURVEY COMPLETED MARCH 22, 2017,WITH THE FINAL HOUSE LOCATION COMPLETED JUNE, FINAL HOUSE LOCATION SOUTH GLENS FALLS, NY 12803 21,2018, AND THAT THIS SURVEY MAP WAS MADE BY ME OR MADE UNDER MY JUNE 22,2018 SCALE V =60' DIRECTION, AND CONFORMS WITH THE MINIMUM STANDARD CODE OF TOWN OF QUEENSBURY,WARREN COUNTY, 518-798-2219 PRACTICE THAT HAS BEEN DEVELOPED BY THE NEW YORK STATE ASSOCIATION OF NEW YORK LS#050670 PROFESSIONAL LAND SURVEYORS.