Loading...
steelsquarepoles-datasheet STEEL SQUARE POLES DIMENSIONS POLE SHAFT- Pole shaft is electro-welded ASTM-A500 Grade C steel tubing with a minimum yield SON— SOB3,SOB5— strength of 50,000 psi.On Tenon Mount steel poles,tenon is 2-3/8"O.D.high-strength pipe. N=2-3/8"(60mm)O.D.x 4-3/4"(121mm)Tenon Bolt-On Mount Tenon is 4-3/4"in length.Straight poles are 4",5",and 6"square. 2-Bolt Pattern HAND-HOLE-Standard hand-hole location is 12"above pole base.Poles 22'and above have a 3" x 6"reinforced hand-hole.Shorter poles have a 2"x 4"non-reinforced hand-hole. BASE- Pole base is ASTM-A36 hot-rolled steel plate with a minimum yield strength of 36,000 psi. Two-piece square base cover is optional. ANCHOR BOLTS- Poles are furnished with anchor bolts featuring zinc-plated double nuts and 14'-39' Sal— washers.Galvanized anchor bolts are optional.Anchor bolts conform to ASTM F 1554-07a (4.3m-11.9m) No Mounting Holes p Grade 55 with a minimum yield strength of 55,000 psi. GROUND LUG-Ground lug is standard. Hand-hole DUPLEX RECEPTACLE-Weatherproof duplex receptacle is optional. GROUND FAULT CIRCUIT INTERRUPTER-Self-testing ground fault circuit interrupter is optional. 12" SF— FINISHES- Each pole is finished with DuraGrip°, LSI's baked-on polyester-powder Single Flood (305mm) Pole Preparation finishing process which electrostatically applies and fuses a polyester powder to the Optional Standard Base Cover pole. Provides an extremely smooth and uniform finish to withstand extreme weather Fa changes without cracking or peeling,and features a five-year limited warranty.Optional DuraGrip°Plus features the added protection of a 3.0 to 5.0 mil thickness of polyester- powder finish plus an inner coating,as well as a seven-year limited warranty. Projection UI I�I (4) DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION: Anchor Bolts 0 Select luminaire from luminaire ordering information Foundation 0Select bracket configuration if required By Other • Determine EPA value from luminaire/bracket EPA chart • Select pole height DRILLING LOCATIONS Side°C„ 0 Select MPH to match wind speed in the application area(See windspeed maps). • Confirm pole EPA equal to or exceeding value from note above • Consult factory for special wind load requirements and banner brackets Side"D"— — — —Side"B" I Side"A"(Hand-hole Side) Sides A B C D Hand-hole Single X D180o X X D90o X X T90o X X X TN120°` X Q90o X X X X Single FBO X Double FBO I X I I X `Other two locations will be 120°to the left and right of Side A. Note:Standard SF and OF pole preparations are located 3/4 of the height of the pole from the base,unless otherwise specified. SHIPPING WEIGHTS- Steel Square Poles 4"(102mm)sq.11 Ga.is approximately 7.50lbs./ft. 4"(102mm)sq.07 Ga.is approximately 10.00lbs./ft. 5"(127mm)sq.11 Ga.is approximately 9.00lbs./ft. 5"(127mm)sq.07 Ga.is approximately 12.50lbs./ft. 6"(152mm)sq.07 Ga.is approximately 15.40lbs./ft. Anchor Bolts(3/4"x 30")(19mm x 762mm) 15 lbs.(7kg)/set Anchor Bolts(1"x 36")(25mm x 914mm) 30 lbs.(14kg)/set ��pSSIFjFO ARRA Funding Compliant �L Project Name i Fixture Type i 4/26/17 ©2017 Catalog# i LSI INDUSTRIES INC. STEEL SQUARE POLES POLE ORDERING INFORMATION TYPICAL ORDER EXAMPLE: 5SQB5 S07G 24 S PLP SF DGP Pole Mounting Pole Series Material Height2 Configuration Finish Options Bolt-on Arm Mount-See pole selection guide S11 G—11 Ga.Steel 14' S—Single/Parallel BRZ—Bronze GA—Galvanized Anchor Bolts for patterns and fixture matches. S07G—07 Ga.Steel 16' D180°—Double BILK—Black SF—Single Flood3 4SOB3-3"Reduced drilling pattern 18' D90°—Double PLP—Platinum Plus OF—Double Flood3 5SOB3-3"Reduced drilling pattern 20' DN90°—Double WHT—White DGP—DuraGrip®Plus 4SOB5-5"Traditional drilling pattern 22' T90°—Triple SVG-Satin Verde Green LAB—Less Anchor Bolts 5SOB5-5"Traditional drilling pattern 24' TN120°—Triple GPT-Graphite OSXX-Pole preparation for 6SOB5-5"Traditional drilling pattern 26' Q90°—Quad MSV-Metallic Silver PMOS Occupancy Sensor4 28' QN90°—Quad 30' Tenon Mount-See pole selection guide 35' N—Tenon Mount Standard SF and OF pole preparations are located for tenon and fixture/bracket matches. 39' (Standard tenon size is 2-3/8"O.D.) 3/4 of the height of the pole from the base,unless 4SON otherwise specified. 5SON 6SON Consult Pole Selection Chart on opposite page No Mounting Holes-Use with: •BKA 41SF&BKA 51SF •BKA X41SF&BKA X51SF Internal Slip-fitters 4SOI 5SO1 ACCESSORY ORDERING INFORMATION (Accessories are field installed) Description Order Number Order Number 4BC-4"Square Base Cover 122559CLR Vibration Damper-4"Square Pole(bolt-on mount only) 172539 5BC-5"Square Base Cover 122561CLR Vibration Damper-5"Square Pole(bolt-on mount only) 172538 6BC-6"Square Base Cover 122563CLR Vibration Damper-6"Square Pole(bolt-on mount only) 178361 ER2—Weatherproof Duplex Receptacle 122566CLR PMOS120-120V Occupancy Sensor 518030CLR5 GFI—Ground Fault Circuit Interrupter 122567CLR PMOS208/240-208,240V Occupancy Sensor 534239CLRI MHP—Mounting Hole Plugs(3 plugs)-for use with 5"traditional drill pattern 132336 PMOS277-277V Occupancy Sensor 518029CLR5 MHD—Mounting Hole Weatherproof Decal-for use with 340120 PMOS480-480V Occupancy Sensor 534240CLR5 3"reduced drill pattern FOOTNOTES: 1-See Area Lighting Brackets 3"Reduced Drill Pattern and Area Lighting Brackets-Bolt-on 5"Traditional Drlll 4-Order PMOS separately.Change"XX"to indicate height and side of pole location Pattern spec sheets for Internal Slip-fitter brackets. for pole preparation.EX:OS18A indicates preparation is to be 18ft.up from pole 2-Pole heights will have+/-1/2"tolerance. base on side A.Optimal distance from ground to sensor is 20ft. 3-See Flood Lighting Brackets section for choice of FBO brackets. 5-OSXX option required.Not for use with Metal Halide fixtures BOLT CIRCLE 4"(102mm)square 5"(127mm)square 5"(127mm)square 6"(152mm)square 10-1/8"(257mm)sq. 10-1/8"(257mm)sq. 10-1/8"(257mm)sq. 12"(305mm)sq. .............. 11"(279mm)Dia.Balt Circle 11"(279mm) ia.Balt Circle 11"(279mm)Dia.Balt Circle 12"(305mm)Dia.Balt Circle B C D J Slotted Slotted Slotted Slotted Bolt Circle 8"-11"(203mm-279mm) 9"-11"(229mm-279mm) 9"-11"(229mm-279mm) 12"(305mm) nc or o t 3/4"x 30" 3/4"x 30" 1"x 36" 1"x 36" Size (19mm x 762mm) (19mm x 762mm) (25mm x 914mm) (25mm x 914mm) Anchor Bolt 3-1/4" 3-1/4" 4" 4" Projection (83mm) (83mm) (102mm) (102mm) Base Plate Opening 3-5/8" 4-3/4" 4-5/8" 5-5/8" for Wireway Entry (92mm) (121 mm) (117mm) (143mm) Base Plate 10-1/8°sq.x 3/4"thk. 10-1/8"sq.x 3/4"thk. 10-1/8"sq.x 1"thk. 12"sq.x 1-1/8"thk. Dimensions (257mm x 19mm) (257mm x 19mm) (257mm x 25mm) (305mm x 29mm) Note:Base plate illustrations may change without notice.Do not use for setting anchor bolts.Consult factory for the base plate templates. Project Name 1 Fixture Type 1 4/26/17 ©2017 Catalog# 1 LSI INDUSTRIES INC. STEEL SQUARE POLES Use ONLY with "Wind Speed Map forASCE7-05 POLESSTEEL SQUARE POLE 90 MPH 100 MPH 110 MPH 120 MPH 130 MPH 140 MPH 150 MPH 4"11 GA 14' 18.7 14.5 11.5 9.1 7.3 5.9 4.6 4"11 GA 16' 15.1 11.5 8.9 6.9 5.4 4.1 3.1 4"11 GA 18' 12.2 9.1 6.8 5.1 3.7 2.7 1.8 4"11 GA 20' 9.5 6.9 4.9 3.4 2.2 1.3 0.5 4"11 GA 22' 7.4 5.1 3.3 2.0 1.1 0.0 0.0 4"11 GA 24' 13.1 9.5 6.8 4.8 3.2 2.0 1.0 4"11 GA 26' 10.7 7.5 5.1 3.3 1.9 0.7 0.0 4"7GA 20' 14.8 1 11.2 8.4 6.4 4.8 3.5 2.4 4"7GA 22' 14.9 11.0 8.2 6.0 4.4 3.0 1.9 4"7GA 24' 12.4 8.8 6.3 4.4 2.9 1.7 0.8 4"7GA 26' 10.1 6.9 4.6 2.9 1.6 0.5 0.0 5"11 GA 16' 29.4 23.0 18.2 14.6 11.8 9.6 7.8 5"11 GA 18' 24.2 19.7 14.5 11.4 9.0 7.1 5.5 5"11 GA 20' 1 20.0 1 14.9 1 11.5 8.8 6.6 4.9 3.6 5"11 GA 22' 20.8 15.5 11.7 8.7 6.4 4.6 3.2 5"11 GA 24' 17.2 12.8 9.3 6.6 4.5 3.0 1.6 5"11 GA 26' 14.8 10.2 7.1 4.7 2.8 1.4 0.2 5"7GA 20' 30.5 23.7 18.6 14.7 11.7 9.3 7.4 5"7GA 22' 1 41.2 32.0 25.4 20.3 16.2 13.2 10.5 5"7GA 24' 36.0 27.9 21.8 17.1 1 13.5 10.7 8.4 5"7GA 26' 32.0 23.8 18.3 14.1 10.9 8.3 6.2 5"7GA 30' 24.1 17.5 13.0 9.4 6.7 4.5 2.8 6"7GA 24' 51.0 39.7 31.3 24.9 19.9 16.0 12.8 6"7GA 26' 44.5 1 34.2 26.7 20.9 16.4 12.9 10.0 6"7GA 30' 34.3 25.8 19.4 14.6 1 10.8 7.9 5.4 6"7GA 35' 24.8 17.8 12.5 8.5 5.4 2.9 0.9 6"7GA 39' 18.6 12.4 7.8 4.4 1 1.6 0.0 0.0 All LSI Industries'poles are guaranteed to meet the EPA requirements listed.LSI Industries is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. CAUTION:This guarantee does not apply if the pole/bracket/fixture combination is used to support any other items such as flags,pennants,or signs,which would add stress to the pole.LSI Industries cannot accept responsibility for harm or damage caused in these situations. Project Name i Fixture Type i 4/26/17 ©2017 Catalog# i LSI INDUSTRIES INC. STEEL SQUARE POLES Use ONLY with "Wind Speed Map forASCE7-10 POLESSTEEL SQUARE POLE 110 MPH 115 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH 170 MPH 180 MPH 4"11 GA 14' 12.5 11.3 10.2 8.5 6.8 5.8 4.9 4.1 3.6 4"11 GA 16' 9.8 8.6 7.9 6.5 5.4 4.4 3.5 2.9 2.2 4"11 GA 18' 8.1 7.4 6.7 5.4 4.2 3.4 2.8 2.2 1.7 4"11 GA 20' 7.1 6.3 5.6 4.4 3.4 2.7 2.1 1.6 1.1 4"11 GA 22' 9.9 8.8 7.9 6.3 5.1 4.0 3.1 2.5 2.0 4"11 GA 24' 8.6 7.5 6.8 5.3 4.2 3.3 2.5 1.9 1.3 4"11 GA 26' 6.8 6.1 5.5 4.2 3.2 2.3 1.6 1.0 1 0.6 4"7GA 20' 10.7 9.7 8.7 7.0 5.7 4.6 3.8 3.1 2.5 4"7GA 22' 11.3 10.2 9.1 7.3 5.8 4.7 3.5 2.7 2.1 4"7GA 24' 9.8 1 8.9 7.8 6.0 4.5 3.5 2.8 2.1 1.6 4'7GA 26' 7.9 7.1 6.1 4.7 3.6 2.8 1.9 1.2 0.7 5"11 GA 16' 18.1 16.4 14.8 12.3 10.3 8.7 7.3 6.3 5.3 5"11 GA 18' 15.7 14.2 12.8 10.5 8.7 7.3 6.1 5.1 4.3 5"11 GA 20' 13.5 12.3 11.1 9.0 7.4 6.0 4.8 3.8 3.1 5"11 GA 22' 1 15.8 14.3 12.6 10.2 8.3 6.5 5.4 4.2 1 3.5 5"11 GA 24' 13.8 12.5 10.8 8.6 6.7 5.2 3.9 3.0 2.1 5"11 GA 26' 11.3 10.3 8.9 6.9 5.3 4.0 3.0 2.2 1.5 5"7GA 20' 20.7 18.8 17.0 14.0 11.7 9.8 7.9 7.0 5.9 5"7GA 22' 25.8 23.3 21.0 17.5 14.6 12.3 10.4 8.8 7.5 5"7GA 24' 1 23.3 21.0 19.0 15.6 12.9 10.7 9.0 7.5 6.3 5"7GA 26' 20.0 18.0 16.2 13.2 10.7 8.9 1 7.3 6.0 4.8 5"7GA 30' 16.4 14.6 13.0 10.3 7.9 6.5 5.2 4.0 3.1 6"7GA 24' 35.0 30.8 28.5 23.7 19.6 16.7 14.0 11.8 10.2 6"7GA 26' 29.2 26.2 23.7 19.3 15.9 13.2 11.0 8.9 7.5 6"7GA 30' 23.6 21.2 19.0 15.2 12.3 9.9 8.0 6.4 5.0 6"7GA 35' 17.6 15.2 13.6 10.7 8.2 1 6.2 1 4.6 3.2 2.1 6"7GA 39' 13.9 11.9 10.4 7.7 5.5 1 3.8 1 2.4 1.2 0.2 All LSI Industries'poles are guaranteed to meet the EPA requirements listed.LSI Industries is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. CAUTION:This guarantee does not apply if the pole/bracket/fixture combination is used to support any other items such as flags,pennants,or signs,which would add stress to the pole.LSI Industries cannot accept responsibility for harm or damage caused in these situations. Project Name i Fixture Type i 4/26/17 ©2017 Catalog# i LSI INDUSTRIES INC.