Loading...
Application TM BOHLER 17 Computer Drive West Alhany, NY 12205 PHONE 518.438.9900 E N G I N E E R I N G FAX 518.438.0900 Via Hand Delivery May 15,2017 Town of Queensbury 742 Bay Road Queensbury,NY 12804 Attn: Laura Moore;Land Use Planner Re: Proposed O'Reilly Automotive Stores Redevelopment 682 Glen Street Queensbury,NY Dear Laura, On behalf of our client, O'Reilly Automotive Enterprises, LLC., we are pleased to submit the Site Development Plans and application to the Town of Queensbury Planning Board for review of the proposed redevelopment project. The Applicant proposes to redevelop 682 Glen Street with a new retail facility. Enclosed please find the following materials in support of this application to the Town Planning Board for Site Plan review: • Fifteen(15)copies of the Application for Site Plan Review dated May 12,2017 • Fifteen(15)copies of the Area Variance Application dated May 12,2017 • Fifteen(15)copies of a Project Narrative dated May 15,2017. • Fifteen(15)copies of the Deed • Fifteen(15)copies of the Short Environmental Assessment Form dated May 10,2017 • Fifteen (15) copies of a "Site Development Plans" prepared by Bohler Engineering, dated May 15,2017. • Fifteen (15) copies of the "ALTA/NSPS Land Title Survey for O'Reilly Auto Enterprises, LLC", prepared by Control Point Associates,Inc.,dated February 28,2017. We look forward to appearing before the Town Planning Board on June 20, 2017 to discuss this project and to appear before the Town Zoning Board of Appeals on June 21, 2017 to discuss the included Variance Application. Please do not hesitate to contact me should you need any additional information or have any questions. Thank you for your assistance with this project. Sincerely, BOHLER ENGINEERING MA,LLC G Joshua D. O'Connor,P.E. CIVILAND CONSULTING ENGINEERS • PROJECT MANAGERS + SURVEYORS • ENVIRONMENTAL CONSULTANTS • LANDSCAPE ARCHITECTS WWW.BOHLERENGINEERING.COM general Ir1fGl`i" al Area Variance Z-AV-41.2017 Tax Parcel ID Number. 302.7-1-28 O'Reilly Auto Enterprises, LLC 682 Glen Street - now bldg., Zoning District: Cl - Commercial lntensi, (former site of Fit Food Fast / Friendly's Rest, Detelled Descrotion of Project Frx;udes curFent&pwo5ed way, The appGcent Le propogjng to redevelo _the site by construcUrg a new}!-.7,453 SIS. 9 stony. Out admgareas, landscetaina, and site lightly in the Town of Queenabur_y. Lot coverage will remail Location of project~ 682 filen Street at the oorner of Clan Street and Glendale Drive. Applicant iVl3 nw. , O'F*MfyAuto Enterpese,LLC ck AddiBS:RoWerpigheaft M&LLC -3 ` Florne Phore -- 77 �IY}�f�,. � �[�,�1 dei[: � �i l W Work Phone' Fax 12-Mall: Agent's Nam: .. ' Bnhier Engineering MA, LLQ Address; 17 Cempuler Ofte west Albany.NY 122x5 Home Phone ; Jog=O"Oonnor dell: 518-5734778 ark Phq.m 51&439-9900 Fax 518-438-0900 E—nail ' jocvnnor ohiereng.00m Owner's C al#ra J&T Tial, fnm Address P.O. Bax 444, Redden,NJ,OB8 69 =a phons Gell INnt Phane A mm Vmfam a Revised RbFch X01+4 i TcAw of QuaenWxW-ZaMng Q#Ifn -742 Bay Road■Queendbury,Ars'12BD4.51&-Mj-U3B Bite Dee[oprrnt Date Area I Type Erxisfing sad,fL pinposed A. Building footprint ,4t&ditian tM.ft. .2,443 61810 7,453 E. Detached Garage NIA MA NIA C. Accessory%ructure(s) NIA NIA WA D. Paved,gravel or other hard surPaced area 18,762 -31879 14,883 E. Pambas f Dem NIA N1A NIA F. Other tJfA hllA NIA 0. Total Non-Penrn ble [Add I-F] 21,208 1,131 22,336 H. Parcel Arae 143,560 Sq.fL I acre] 33,173 0 33,173 L Pe n1age of lmpermeabbl Ivrea of Site ll=G" 03.9% NIA 67.3°Y� Setback 8equ[rernents Area :L RegUI red EAsting Pro o Rant[I] 76, 12.7' 72.8' Front[2] 75' 15.6' 21.1' Shoreline NIA NIA MA Side Yard 11j NIA NIA NIA Side Yard[2] NIA NIA NIA Dear Yard[1I 25' 92.3' 32-1' Dear Yasd[ ] 25' 123.x' S&W Travel Corridor 75' 23,8' 72.8" Height[max] 4th 2o.2' 18.0' Permeabli ty 30% 36.1% 32.7% No. of parking sp arm 38 38 25 Area Variance Revised Marah 2014 rcwn Of QLmorwhOry Zoning Mks•742 May Road 1 Qusensbwy.NY 12W v 51 a-761-81238 dd tlonal Project Info aHon 1- Vtfili !ha proposal require a Septic 1ladaince from thq Team Board of Health? . If the parcel has previous apprmis. WI:appftaWn number(oX Sign Variances for Fit Food Fast restaurant 3. Does this projent require coVzrage under the M DECtomnwatw Pollution Prevention Progmrn? Yee No 4. Estimated project duration. Start Date July 2917 End Date .fuly 2018 5. Estimated total cost of proja�k 1 Million S. Total a ma of tand disturbance for prgart 0.68 acres Floor Areae Ralhio Wartcsheet FLOOR AREA NATIO (FAR)—The relationship of buitding sine to lot same.derived by dividing the total building floor area by etre tot eke In square deet,yielding a perwntage, . symbol AW Area Ratio VARL Wa6s ont Reekbritial VMY Oommercl+al Modembd ornmer l Irrtenstva CM f Dl Q,3 Main Scree# Ms 0.3 A- The combined 4m or so sq=m taataga,as measure from error welts of all struchwas on We pmpady.kr-k ding ak Room of the saes, garages, ba meets and adios with more than five (5) feet of cuing helght and camwW parches. Bulldtng square footage does not Include: Open deck, docks and that pmllon of om erect docks ending over water and one storage shed of "a hundred twenty (120) sq+aam feet or tress. Any addiffonal sheds gilt be hedluded.(Sas'FLOUR AREA FiAM01. EL Commercial or IndustriW*the total area In square fest as measured f n etre Weriar of the outside walla of a bullding or struchav, and when applicable, Um sum k ftl of all Four areas of the principal and eocessory buildings or structures as the pMj0d 51te. A. Parcel Area X33 173 e .{h B. Exlstfp PloorAma *21443 .ft, see above definldon 0. Pro"d Additional Floor Area {t, D. Propesgd Total Floor Area e. Total Allovmble l=looa'Area t9,952 Aree x sea abs tabs �yV E is Wrgar ftrr D, a vaejanoe or regions to your &n may be needed. Please consult Area Verlance Ravtead M=h 2019 3 Tom of Oueenbury*Zoning Offiea+742 Bay road+Queensbury,N1'12804■6W51 M39 Gompli;anw xri#h Zoning Ordinance Requesting rdef flour SECT(ON- 1-79-3-040, 179-4-990 Need rellef from ft req&emengq)listed lsWaw which can not be met by the projed W proposed. zauMMt-2p MSethadc []Buffer one pLotWidth (aoftwRar-knfl The following questions rets the criteria for granting this type of variance. Please complete ftm;use addillonal sheets if needed. 1 Whether an undesirable change WO be produced In the character of the neigRl=h=od or as detriment to nearby property Wll be created by the granting of this area varienoe? This project is a redevelopment project. The front yard setback proposed gill be more in co than the current facility, The redu cod parklrig count is adequate for the lova volume use Fair parts store). . Mather the benefd sought by the applicant can be achieved by some method,feasible far the epplicarkt to put u%other lhan an area variance? More parking could ba added but it is not needed and would create more storm ater. The proposed site Improvements would be more in oonfbrmance than the existing facility. 3. Whether tie mquested area v ante Is substantial? The proposed redevelopment project would need less relief than the current facility and thu requested variances would not appear to be substantial. 4. VN wftr the proposed variance uili have an adveme eifcct or impact on the physical or anwonmental a editions in the neighborhood or tfst t? The existing use of the site has numerous non-conform ies. The proposed project anki pal non-conformities to the benefit of the env]ronment and the neighborhood. The proposed bi odors, parking as a restaurant and the building has been placed to act as a buffer betweer 5. Whether the alleged di f y was self-created? Lot has existing non-conformance In its size and configuration, This is a redeveliGpment prc Arca Va&rw F wired Manch 2c14 4 Town or Queensbury•Zoning OIGca-742 Say Mad+Queansbuy,MY 128104.51 e-761.823E Submittal of a stamped aad sigld SUE= MAEdeplafing a mling and Proposed conditions shelf include the Items as noted below. A. GENERAL SHEVT a 1 M,Name,Address of appocant 8 person raspansite far ptapara un of dtuMrrg Applicatian Dead = 3 Narth arm.Tax Mop ID,dale preparers pnd scale DMnimm 1 in.a dQ 11.1 CT1.0, C2.1 A B=dmim of ft pmpel'1y pk Mad to scale.zodrig boundary G2.1 5 Prinetpul etmalum,eoraassory Orudures wiUr extedor dJmer4dDns C2.1 •B I SIM RM ovwnaMiR W.D(,ldaasstDmanarams,4d hravram perhina sreaa,ot= eAWng A prapmd C2.j 7 Selbarrkafor911stnrdureaarrdbnpr4vemame: mdsdnp$prnpused C2.1, Suppe a Etevagau and Iloor pians of all prapasad and afrecWd struOuree EL WAMR4 r9G-1�IfE _ , 8H 7 I Frjad owaae dsposel radMes,daelga deWI2, mrmtruchn daWls,fkw rales,and rof bedraoms prop oomer - 2 Watar supply PAA,mTQ&sopft on adJobkig Iate with vMmmikm dla mow to exidq ur Wpmd an-ulta water supply ared saptlo - 3 Sep w Won dtetunQas for proposed umge dfap,oeal sysbm iu well and water badias 4 EadsOng publ8c ar private water supply( O,lis p%ot;.I. Method nr seeudng PUNIC or p water.Iorralion, design etld emwt cirri of water aapp4y IncTrrdfreg duly walker usapdo - 9 Peraalallon#est locadw and results .. C. PJ0.Rmr-F PERk i�su.AREAS SWET# 1 Number orgramrequired for pn4aetfnduftcatoutai?ar1$and lfAol&n: aAsft,&propmwd C2.1, Survey 2 No.of wdsttng parking space%manber to be rammmd,number to malrrtadn and"of vwftkrg mnlerlal 3 Provtelan far paideakdao and hwWkAp%==mW per kbM exNting A proposed +4 DaWgF►drMis of ke ase,egress,lbadMg edeas and cottinge oxb lrp A proposed - g Location and ctmradw of green areas(wdaOg and pmpcaacQ. moWfi affon to gmen area, buffer zona to remain 1mwwwbed - a Lloft,location and design of all Wating orad pgmaW oubioarlighdng - AODMC IAL SITEDk 6P ,ODEAMELL O'M- - SHED' i On4le&a4acenkwaiercourses,streams,dvers,lake end wedand8 - 3 UUMylenargy dlWhutlop vAWa[gas.edeotrlrt saran letephane]. er %ft&Mposed - 3 Laoaitan,design and cananction detalts of all m mnp wrd propped arts#lrnPro"manls Ineludinp: drains, _ culverts,rataWra walls,far=,fgia&emergency farms End hydrants.etc. d Square footage of big.arae Proposed for affkm%I'nanufadudng,relaA sales ar other comme lal ar Nil m. _ mftk ng A proPaand $ SlgMer Location,arae,We.da$dan and sob @*Wng Aproposed - f WaFrer Request pravfida FeW oft 2pplkatiodl requesifnp ogwatvera: pleaae reRwencaspediTc hems g Cvmmerdatllndu Wal Devebapmerd requires subrrdsslon of Landsceptng,SlOrnswater Manageanent,Gadn &Llglydtig PJende " h Identllicasion of Federat We or County penntis saquhed for the pn4acl lagelherwith a recwd of appitcalkm rot all neoemserry permlta Area Var eam Wee4 Mbrch 2014 Tovm of Que enshury o Zoning office-742 Bay Road•GAar sbvey,NY 12004*516 761-823B TO W-N OF Q EENS U Y 742 Say load, Qaffuisbifry, NY, 22804-5902 May 23,2017 O'Reilly Auto Enterprises, LI. c/o Bohler Engineering RIA,LLC ,Atte. Joshua O'Connor 17 Computer Drive West Albaj)y,NY 12205 Re: Nr,-w Commercial Building Proposed Use: Aat) Parts Retail Business 682 Glen Street Tax Map Parcel: 302.7-1-28 Dear'Mr. O'Connor: I am writing you with regards to my review of the above-referenced project and to document the recent conversations between you and Laura Moore of any office. Upon my review I find that your proposal will require an Area Variance and Site Flan )review prior to the commencement of the project. Specifically, an Aria Variance is required as your plan offers the demolition of the existing building and construction of a new 7,453 sq. $. building that cannot meet the minimum setback and permeability requirements of our Commercial Intensive district, Site Plan Review is required for the new commercial use; auto parts retail business and the associated site improvements. I understand that you may have already submitted the neoessxy applications for review by our Boards during the tuonth of June 2017. This letter serves as the required denial letter for the processing of your application packages. Should you have any questions or comments regarding your application, please do not hesitate to Contact this office. Sincerel , . Craig Brown Zoning Administrator CB1sh LACraig Brow&2017 Lcttors0enW O'Reilly Auto Enterprises 5_23-17,doe " Home of Nonoral Bgauty ... A Good Place to Live " { dh A,,--tz) Pre-Submission Conference Form [179-4-04D] 'i. Tax Map ib 302.7-1-28 3 ..) 2. ZaWnfl Classil!rcation I { �� 1 3. Reason for Ravtaw: Proposed O'Rellly Auto Parts Store } 4. Zoning Section#; - Fr�" � C 1 „' S. pre-Subrrrission Meeting Notosr Outstand[nrg Itorw To Bo Add re ed include:a. C_� Q Deed � Yes bio k), General Iriformdon eornpJete Yes No Site Development Data Complete �` Yes No SeUrk Requirements Complete Yes �wo AddiEaar�al project Information Complete es No FAR addressed Yes No Compfiar with ZoAhg O finance 7yes No heckftt-items addressed Yes No Environmental Form onmpleted —Yes a Signature page completed Yes No 140�(r tib4Q + e-- e I C } Q Ile Y ;} rn f .Staff RepreseWtive: Appllcant f Agent: Date: � Area Variance Revised March 2094 6 Town of Queensbury-Zontag Office-742 Bay Road-Queenmbury.MY 92804.598-789-8,238 Signature Pdge 'This page includes fete 1.)Audhorizagen to Act as Agent Farm: 2,) EE&Oerirrg Fed pl chlor; 3.)ALdhnrixatlan for site VWIW, 4.) Other Permit Responsibilitlm 6.) ORfatal Miseting DUKiosure and 6.) Agmernent to provide (Iommentallort squired, Orr W&AGENT FaFiw. Complete the toffrnft If the OWNER of the property is not ft lama as the applicant J 6, 1 1sai, Ino. Designates: Asaunt regarding; Variance Sfte Plan SubdiWdon 1=ar Tax Map No.: . Beckon t Slook :O Lot DeadRelamnew. i�isook Page .Dates OVll Bt SIGNATURF- Q13 DA'TE' 511 02017 Arspucnar's AaErar Fr Compleft the following if the APPLICANT is unable to alharld the meefing of wishes to be represented by another party. fav LyKelli is Interposes, LLL; DesigpaWar bonier As egant regar&q-. VatiW=T _Site Pian Suhd{Walarn For Tax MR p Na: 0Y4 Seetian I Bock Att I Lot Deed Were ac JUG BV* P tate APPLICANT SIGNATURE DATR 2.) ENOINEMIP.MMEtli2E— Appardurrs nay be referred to the Tawe oorrsWUm enpineer for review of sepso desTm aft. drainage, rbc. as delmmined by the Zooko as PTeasrOg Department Fees far snglneerkrg rawlsw smvk w will be dtiarged dire+to 00 appolcant. Fees far enginam ng review w111 rrot a=aad 5 JADD wifhw4 Adwict9tlorl to Itis eppleanl. 3.) AUTHDRIZA110W F:09 SrFF.MUM; By elq*g Ude page and artbrnitilng ire appiWIon mateftb a2schad hem1n,Hw Owner, Appiicaet, and ilfelharilhair aganits) hmby aullarkm Um Zon ft goerd or Planning gaard and Town Stalf to enter the augag prupnl=fur the purpose ofnwiayft itye aWc2gm miNad, 4.) QjdgLPJjR=RESRGISIBIUIIF_S, QtharporrnU rimy da required for sona mcdon oral alton acUty mubrequent to sppmvd by the 70n1ng hoard or Pfannkm DDard. It to the appliaanea responaitift to obWn arty addldarrml penni@e. Sj ,QM%[ LMEIFI3148 MINUTES D1SMUSURR It la Itre pracke of the Ccmmuoity Davelopawt Doperimem to have a designated 0owgrapherWpe reeard the procaftr.of rnaetlrrgs rete*q f m appPealloN and minuhm tray mftd from those iapem anrlstirfutW Ute of ctel record orall prgoo d ap, 6.) affl I:NT TO PROVIDE VOCUKENTATION FMCFII D: 11 lire undem%rned, hawe tharougNy read and underswW to Irtainrotlans far strbdrtladan and aglae to tit6 submfsdon reWmmetrta. I aokneWedge no omuhuctian aclMUes zW km commermud prfor to Irsuance of a ualld psmrlh I c*rllfy that Uva aplAcettom pferre and e;rpparing matsrfals are a tate and complete staternentwescdpllon of the exon eondlUons incl ft wbrk p"am d. and that 0 work will be pedbmW in accordance Qh Itre apMned pigs and In caonfommmewith local=nTng mgulffft , i 2rckrva+r Wge that pdorto ogt Wnq Um WlltTes proposed, I or my ageals,will ablairt a owtMoaGe ofomupancyas necassery. I alio understand[hat Ummayhe rogLiredto pmmib an as-built auruey by a f$oensed land w reeyor or all no%*voraslrudmd implies prlos to lssrmnoa of a aarfllcats or cccupauy I have read and agree to the above.4 ) igA —� 9mA [ApPlk nl] Print Dame[ApplicarAl Date Oned J r J 1 SIgnatum jAgen Px�t Name[Agent] Date signed 7 Area Varkmee KSUEsEid Mamb 2014 Tom of QueerrsToury•BoWng Office*742 Bay Road■Glueewbmy.NY 12aM■510-761-9298 Short Environmental Assessment Form Part I -Project Information Instructions for Completing Part 1-Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding,are subject to public review,and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency;attach additional pages as necessary to supplement any item. Part 1-Project and Sponsor Information Name of Action or Project. Proposed O'Reilly Auto Parts Store Project Location(describe,and attach a location map): 682 Glen Street,Queensbury,NY Brief Description of Proposed Action: The applicant Is proposing to redevelop the site by demolishing the existing restaurant buildingifacilities and constructing a new 17,453 SF,1 story,auto parts retail store along with parking,loading areas,landscaping,site lighting and appurtenances.Lot coverage will remain generally the same and provide about 33%greenspace. Name of Applicant or Sponsor. Telephone: 518-438-9900 O'Reilly Auto Enterprises,LLC c/o Bohler Engineering MA,LLC E-Mail: msterhoudt@bohiereng,com Address: 17 Computer Drive West City/PO: State: Zip Code: Albany NY 12205 1.Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO I YES administrative rule,or regulation? If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that ❑ may be affected in the municipality and proceed to Part 2. If no,continue to question 2. 2. Does the proposed action require a permit,approval or funding from any other governmental Agency? NO YES If Yes,Iist agency(s)name and permit or approval: ❑ ❑ NYSDOT-Highway Work Permit;Town of Queensbury Planning Board-Site Plan Review,Town of Queensbury Zoning Board of Appeals-Area Variances;Town of Queensbury-Building,signage and utility permits 3.a.Total acreage of the site of the proposed action? 0.76 acres b.Total acreage to be physically disturbed? 0.68 acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? 0.76 acres 4. Check all land uses that occur on,adjoining and near the proposed action. m Urban ❑Rural(non-agriculture) [:]Industrial m Commercial m Residential(suburban) 1:1 Forest ❑Agriculture ❑Aquatic [:]Other(specify): ❑Parkland Pagel of 3 5. Is the proposed action, NO YES NIA a.A permitted use under the zoning regulations? ❑ 91 ❑ b.Consistent with the adopted comprehensive plan? ❑ ❑✓ ❑ 6. Is the proposed action consistent with the predominant character of the existing built or natural NO YES landscape? ❑ ❑ 7. Is the site of the proposed action located in,or does it adjoin,a state listed Critical Environmental Area? NO YES If Yes,identify: ❑ 8. a.Will the proposed action result in a substantial increase in traffic above present levels? NO YES b.Are public transportation service(s)available at or near the site of the proposed action? ❑ ❑ c.Are any pedestrian accommodations or bicycle routes available on or near site of the proposed action? ❑ 0 9.Does the proposed action meet or exceed the state energy code requirements? NO YES If the proposed action will exceed requirements,describe design features and technologies: ❑ 0 10. Will the proposed action connect to an existing public/private water supply? NO YES If No,describe method for providing potable water: El ❑ 11.Will the proposed action connect to existing wastewater utilities? NO YES If No,describe method for providing wastewater treatment: ❑ ❑ 12. a.Does the site contain a structure that is listed on either the State or National Register of Historic NO YES Places? ❑ ❑ b.Is the proposed action located in an archeological sensitive area? ❑ ✓ 13.a.Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES wetlands or other waterbodies regulated by a federal,state or local agency? b.Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? ❑ ❑ If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres: 14. Identify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply: ❑Shoreline ❑Forest ❑Agricultural/grasslands ❑Early mid-successional ❑ Wetland ❑Urban m Suburban 15.Does the site of the proposed action contain any species of animal,or associated habitats,listed NO YES by the State or Federal government as threatened or endangered? a El- 16. 16.Is the project site located in the 100 year flood plain? NO YES J 17.Will the proposed action create storm water discharge,either from point or non-point sources? NO YES If Yes, Ela.Will storm water discharges flow to adjacent properties? El NO mYES b.Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? If Yes,briefly describe: ❑NO mYES existing conditions. Page 2 of 3 18.Does the proposed action include construction or other activities that result in the impoundment of NO YES water or other liquids(e.g.retention pond,waste lagoon,dam)? If Yes,explain purpose and size: , ._ _ _ ❑ ❑ 19.Has the site of the proposed action or an adjoining property been the location of an active or closed NO YES solid waste management facility? If Yes,describe: _ El 20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES completed)for hazardous waste? If Yes,describe: . 21 n I AFFIRM THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponso name: O'Reilly Aulo live Stores,Inc.(Contact Tim Williams) Date:0611012017 Signature: PRINT FORM Page 3 of 3 LED AREA LIGHTS - LSI MIRADA (XALM) US&Int'I.patents pending DISTRIBUTION/PERFORMANCE-Proprietary silicone refractor optics provide exceptional coverage and uniformity in Types 2,3,5W and FT Internal Louver(IL)option available for >* improved back-light control without sacrificing street side performance. ENERGY SAVING CONTROL OPTIONS-DIM-0-10 volt dimming enabled with controls by ' others.Available with integrated LSI Controls wireless modules. _ OCCUPANCY SENSING(IMS)-Optional integral passive infrared motion and daylight sensor activates switching of luminaire light levels.High level light is activated and increased to full bright upon detection of motion.Low light level(30%maximum drive current)is activated when target zone is absent of motion activity for-2 minutes.Sensor is located on the center of the access cover and has a detection cone of approximately 45°. LEDS-Select high-brightness LEDs in 5000K,4000K,and 3000K color temperature,70 CRI. HOUSING-Rugged die-cast aluminum housing contains factory prewired driver and optical _ unit.Cast aluminum wiring access door located underneath.Fixture sealed to IP65. DOE LIGHTING FACTS MOUNTING-Tapered rear design allows fixtures to be mounted in 90°and 120° Department of Energy has verified representative product test configurations without the need for extension arms.Use with 3"reduced drilling pattern. data and results in accordance with its Lighting Facts Program. Wall mount brackets are available for direct mounting to wall. Visit www.lightingfacts.com for specific catalog strings. ELECTRICAL-Two-stage surge protection(including separate surge protection built into LIGHT OUTPUT-XALM electronic driver)meets IEEE C62.41.2-2002,Location Category C.Available with universal Lumens(Nominal) watts voltage power supply 120-277 VAC(50/60Hz input),and 347-480 VAC.Optional PCR and Type 2,Type 5W,Type 3 and Type Fr (Nominal) photocells(PC)are available in 120,208,240,277,347 and 480 volt(supply voltage must SS 17100 154 be specified). Y HO 25300 242 DRIVER-Available in SS(Super Saver),HO(High Output)and VHO(Very High Output) u 31700 315 drive currents.Components are fully encased in potting material for moisture resistance. ssS 18300 154 Driver complies with FCC standards.Driver and key electronic components can easily be o HO 28000 242 accessed. e uHO 33000 315 OPERATING TEMPERATURE--40°C to+50°C(4O7 to+1227) SS 18500 154 HO 29300 242 FINISH-Fixtures are finished with LSI's DuraGrip°polyester powder coat finishing process. uHo 35300 315 The DuraGrip finish withstands extreme weather changes without cracking or peeling. LED Chips are frequently updated therefore values may increase. Other Standard LSI fIDISheS available.Consult factory. WARRANTY-LSI LED fixtures carry a limited 5-year warranty. PHOTOMETRICS-Please visit our web site at www.isi-industries.com for detailed photometric data. SHIPPING WEIGHT(in carton)-One fixture:30 lbs.(13.6 kg). LISTING-UL listed to U.S.and international safety standards.Suitable for wet locations. For a list of the specific products in this series that are DLC listed,please consult the LED Lighting section of our website or the Design Lights website at www.designlights.org. This product,or selected versions of this product,meet the standards listed below.Please consult factory for your specific requirements. ARRA aU as R OKS E C IP65 Ponding Co noiant wLISTED. COMPLIANT location Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment-Luminaire Vibration 1.513 requirements. Project Name I Fixture Type I 03/1/17 02017 Catalog# I LSI INDUSTRIES INC. LED AREA LIGHTS - LSI MIRADA (XALM) LUMINAIRE ORDERING INFORMATION TYPICAL ORDER EXAMPLE, XALM FT LED HO 50 UE WHT Prefix Distribution Light Drive Color Input Voltage Finish Optional Controls Options Source Current Temperature XALM 2-Type 1111 LED SS-Super Saver 50-5000K UE-Universal BRZ-Bronze Wireless Controls System 1,2 Options 3-Type III HO-High Output 40-4000K Voltage BILK-Black PCM-Platinum Control System PCR 7P-Photoelectric VHO-Very High 30-3000K (120-277V) GPT-Graphite PCMH-Host/Satelite Platinum Control Control Receptacle e 5W-Type V Wide Output MSV-Metallic Silver System IL-Internal Louver House FT-Type FT 347-480 WHIT-White GCM-Gold Control System Side Shield Universal PLP-Platinum Plus GCMH-Host/Satelite Gold Control System Voltage SVG-Satin Verde DIM-0-10 Volt Dimming(required for (347-480V) Green satellite fixtures)3 (Blank)-None Stand-Alone Control (Blank)-None DIM-0-10 Volt Dimming(from external signal)3 BLS-Bi-level Switching(from external 120-277V signal)3 IMS-Integral Motion&Daylight Sensor 4,5 LUMINAIRE EPA CHART-XALM ACCESSORY ORDERING INFORMATION (Accessories are field installed) i Single 0.6 Description Order Number Description Order Number f i D180° 1.1 PC120 Photocell for use with PCR option(120V) 1225148 DFK208,240 Double Fusing(208V,240V) DFK208,240 u PC208-277 Photocell for use with PCR option(208V,240V,277V) 122515 8 DFK480 Double Fusing(480V) DFK480 u D90° 0.9 PC347 Photocell for use with PCR option(347V) 1225168 FK347 Single Fusing(347V) FK347 u tai T90° 1.9 PC480 Photocell for use with PCR option(480V) 12251801 PMOS120-120V Pole-Mount Occupancy Sensor 518030CLR" FK120 Single Fusing(120V) FK120u PMOS208/240-208,240VPole-Mount Occupancy Sensor 534239CLR" W* TN120° 1.9 FK277Single Fusing(277V) FK277u PMOS277-277V Pole-Mount Occupancy Sensor 518029CLR11 090° 21 IMS/PC Remote Configurator Tool 584929 PMOS480-480V Pole-Mount Occupancy Sensor 534240CLR" IL-Integral Louver HSS BKS XBO WM'CLR Wall Mount Bracket 382132CLR FOOTNOTES: 1-For wireless controls information and accessories,see Controls Section. 6-Photocell must be ordered separately.7 pin standard.See Accessories. 2-Requires a Site Manager and override switch.Not compatible with IMS or BLS Option. 7-Not available with IMS Option or Wireless Control System 3-Not compatible with IMS. 8-Factory installed PCR option required.See Options. 4-Not compatible with DIM,BLS or Wireless Control System. 9-Fusing must be located in hand hole of pole. 5-IMS is a Waft Stopper Dual Sensor(Daylight&Motion)which is field adjustable,via a hand 10-To be used in conjunction with PCM/GCM control modules in fixture.Consult held remote Illustrator tool,which must be ordered separately. factory. 11-Type II not DLC Qualified. DIMENSIONS 13-1/2" 31.3/16" (343mm) (793mm) 7-1/7' (191mm) IMS Remote Hand-held Illustrator Tool IMS Motion& Daylight Sensor Photo Control Receptacle 10.1/2" o �(267mm) \ / 71/4"(184m m) Bottom View Top View Project Name 1 Fixture Type 1 03/1/17 ©2017 Catalog# I LSI INDUSTRIES INC. LED AREA LIGHTS - LSI MIRADAJXALM) BUG LISTING XALM -Type 5 XALM -Type 3 Drive Current Color Temp.` Lumens Watts LER BUG Rating Drive Current Color Temp.` Lumens Watts LER BUG Rating VHO 30 30,344 314 97 133-UO-G4 VHO 30 28,742 315 91 133-UO-G4 VHO-IL 30 25,003 314 80 132-UO-G4 VHO-IL 30 22,382 315 71 132-UO-G4 HO 30 24,654 241 102 133-UO-G4 HO 30 24,973 241 104 133-UO-G4 HO-IL 30 20,130 241 83 132-UO-G4 HO-IL 30 18,937 241 79 132-UO-G4 SS 30 17,553 154 114 132-UO-G3 SS 30 15,927 154 103 132-UO-G3 SS-IL 30 14,552 154 94 131-UO-G3 SS-IL 30 12,406 154 80 131-UO-G3 VHO 40 33,872 314 108 133-UO-G4 VHO 40 32,084 315 102 133-UO-G4 VHO-IL 40 27,910 314 89 132-UO-G4 VHO-IL 40 24,985 315 79 133-UO-G4 HO 40 27,520 241 114 133-UO-G4 HO 40 27,876 241 116 133-UO-G4 HO-IL 40 22,471 241 93 132-UO-G4 HO-IL 40 21,139 241 88 132-UO-G4 SS 40 18 874 154 122 B2 UO G3 SS 40 18,858 154 122 B3-UO-G3 SS-IL 40 15,647 154 1 102 B1 UO G3 SS-IL 40 14,362 154 1 93 132-UO-G3 VHO 50 35,282 314 113 133-UO-G4 VHO 50 33,421 315 106 133-UO-G5 VHO-IL 50 29,073 314 93 132-UO-G4 VHO-IL 50 26,027 315 83 133-UO-G4 HO 50 28,667 241 119 133-UO-G4 HO 50 29,037 241 120 133-UO-G4 HO-IL 50 23,407 241 97 132-UO-G4 HO-IL 50 22,020 241 91 132-UO-G4 SS 50 18,874 154 122 132-UO-G3 SS 50 18,858 154 122 133-UO-G3 SS-IL 1 50 1 15,647 154 1 102 B1-UO-G3 SS-IL 50 14,362 154 1 93 132-UO-G3 XALM -Type FT Color Temperature:30-3000K,40-4000K,50-5000K Drive Current Color Temp.` Lumens Watts LER BUG Rating SS 30 17,471 154 113 134-UO-G2 SS-IL 30 11,003 153 72 132-UO-G2 HO 30 24,676 241 102 135-UO-G3 HO-IL 30 14,825 241 61 132-UO-G3 VHO 30 29 911 314 95 B5-UO G3 VHO IL 30 17,907 314 57 132-UO G3 VHO 40 33,389 314 106 135-UO-G4 VHO-IL 40 19,988 314 64 132-UO-G4 HO 40 27,807 242 115 135-UO-G3 HO-IL 40 17,109 242 71 132-UO-G3 SS 40 18,786 154 122 134- 2 SS-IL 40 1 11,831 153 1 77 132-UO-G2 VHO 50 34,780 314 111 135-UO-G4 VHO-IL 50 20,822 314 66 133-UO-G4 HO 50 28,693 241 119 135-UO-G3 HO-IL 50 17,238 241 71 132-UO-G3 SS 50 18,786 154 122 B4-UO-G2 S-IL 50 1 11,831 153 1 77 132-UO-G2 Project Name I Fixture Type I 03/1/17 ©2017 Catalog# I LSI INDUSTRIES INC. MIRADA WALL SCONCE (XWM) US&Int'I.patents pending SMARTTECTM-LSI drivers feature integral sensor which reduces drive current,when ambient temperatures exceed rated temperature ENERGY SAVING CONTROL OPTIONS-DIM-0-10 volt dimming enabled with LSI wireless controls. /i OPTIONAL INTEGRAL MOTION SENSOR-Passive infrared motion sensor activates switching of luminaire light levels.High level light is activated when passersby enter target zone and increased to full bright in 1-2 seconds.Low light level(30%of maximum drive current) is activated when target zone is absent of motion activity for 5 minutes and is gradually ramped down(10 seconds)to low level.Sensor detection range 110°horizontal x 93° vertical x 10 meters maximum distance. LEDS-Available with 5000K,4000K or 3000K color temperature,70 CRI min. OPTICS/DISTRIBUTIONS-Ultra-high efficiency reflectors provide three distributions.Choose from Type 2,Type 3 or Type FT. DOE LIGHTING FACTS HOUSING-Three-piece die-cast aluminum housing is smoothly contoured low-profile shape. Department of Energy has verified representative product test Mounting hardware is stainless steel or electro-zinc plated steel. Housing and optical unit data and results in accordance with its Lighting Facts Program. are sealed with extruded silicone gasket;supply conductors with molded EPDM bushing. Visit www.lightingiacts.com for specific catalog strings. OPTICAL UNIT-Proprietary silicone refractor optics provide exceptional coverage and uniformity.Pressure stabilizing breather allows super-tight protection while preventing LIGHT OUTPUT-XWM-3 5000K CCT cycling from building up internal pressures and vacuums that can stress optical unit seals Lumens Wattage LPW WALL MOUNTING-Galvanized-steel universal wall mounting plate easily mounts directly 03 3410 1 29 117 to 4"octagonal or square junction box.EPDM gasket is supplied to be installed between 04 4417 40 111 mounting plate and junction box,sealing junction box from entrance of water.Universal 06 6609 59 113 plate permits fixture to be mounted in uplighting(indoor only)or downlighting position. 08 8610 82 105 ELECTRICAL-Two-stage surge protection(including separate surge protection built into LED Chips are frequently updated therefore values may increase. electronic driver)meets IEEE C62.41.2-2002,Location Category C.Available with universal voltage power supply 120-277VAC(50/6OHz input)or 347-480VAC. DRIVER-Drivers are dimming,standard.Components are fully encased in potting material for COVERAGE DIAGRAM IP65 moisture resistance.Driver complies with IEC and FCC standards.Driver can be easily accessed. SIDE VIEW EMERGENCY OPTIONS-Optional integral emergency battery-back-up options are available. BB option operates in 0°C to 60°C ambient temperature and CWBB operates in-20°C to ° -- -- -- --- -- --- -- -- -- 60°C ambient temperature.When primary AC power failure occurs,both options operate 10 LEDs for minimum of 90 minutes. 27ft -- -- - - - _____ OPERATING TEMPERATURE- -40°C to+50°C(407 to+1227) 40ft FINISH-Fixtures are finished with LSI's DuraGrip°polyester powder coat finishing process. son 40ft soft 20ft 1Oft 0 loft 20ft 30ft 40ft son The DuraGrip finish withstands extreme weather changes without cracking or peeling. WARRANTY-LSI LED fixtures carry a limited 5-year warranty. TOP VIEW PHOTOMETRICS-Please visit our web site at www.isi-industries.com for detailed son photometric data. SHIPPING WEIGHT(in carton)-30 lbs./13.6Kg LISTING-UL listed to ANSI/UL1598,UL8750 and other U.S.and international safety 25n standards.Suitable for wet locations in downlight position. This product,or selected versions of thisproduct,meet the standards listed below.Please consult factory 0 _ loof< for your specific requirements. RoHS `@as E LISTED ® ARRA IP65FCc 25ft COMPLIANT oyet location Funding Compliant i 50ft 25ft 0 25ft ri Project Name l Fixture Type l 12/08/16 ©2016 Catalog# l LSI INDUSTRIES INC. MIRADA WALL SCONCE (XWM) LUMINAIRE ORDERING INFORMATION TYPICAL ORDER EXAMPLE: XWM FT LED 08 50 UE WHT IMS Prefix Distribution Light Source Outputs Color Temperature Input Voltage Finish Optional Controls Optional Sensor/Options XWM- 2-Type 2 LED 03-3,400 Lumens 50-5000K UE-Universal BILK-Black Wireless Control Systeml.2 Sensor Mirada 3-Type 3 04-4,400 Lumens 40-4000K Voltage BRZ-Bronze (blank)-None IMS-Integral Motion Sensor4 7 Wall (Wide Throw) 06-6,600 Lumens 30-3000K (120-277) GPT-Graphite PCM-Platinum Control System Sconce FT-Type 4 08-8,600 Lumens MSV-Metalic Silver GCM-Gold Control System Options (Forward Throw) HV-347-480 PLP-Platinum Plus DIM-0-10 volt dimming BB-Battery Back-ups WHT-White (required for satellite fixtures) CWBB-Cold Weather Battery Back-ups Stand-Alone Control (blank)-None DIM-0-10 volt dimming3 (from external signal) ACCESSORY ORDERING INFORMATION' (Accessories are field installed) Description Order Number Description Order Number XWM SW BILK-Surface Wiring Box(Available in black only) 356915BLK DFK208-Double Fusing DFK208 FK120-Single Fusing FK120 DFK240-Double Fusing DFK240 FK277-Single Fusing FK277 DFK480-Double Fusing DFK480 FK347-Single Fusing FK347 IMS/PC Remote Configurator Tool' 584929 FOOTNOTES: 1-For wireless controls information and accessories,see Controls Section. 5-Not compatible with Wireless Control System 2-Requires a SiteManager and override switch.Not compatible with battery back-up, 6-Not available with BB,CWBB,IMS Option or Wireless Control System IMS or HL Option. 7-IMS is the WattStopper Dual Sensor(Daylight&Motion)which is field adjustable,via a handheld remote 3-Not compatible with IMS Option configurator tool" 4-Not compatible with DIM or Wireless Control System B-Output based on type 3 optics in cool white color temperature,see IES files for exact delivered lumens DIMENSIONS 7-1/2" (191mm) 12.3/4" o OOO o 4-1/211 ti I r_— (323mm) (114mm) 0 00 0 5.5/16" (134mm) 19.15/16" (505mm) Project Name I Fixture Type I 12/08/16 ©2016 Catalog# I LSI INDUSTRIES INC.