RC-000278-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000278-2017 Date Issued: Monday, October 23, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000278-2017
has been completed.
Tax Map Number: 308.7-1-69
Location: 58 RICHMOND HILL DR
Owner: Mission Builders,LLC
Applicant: Hodorowski Homes
This structure may be occupied as a: Single Family Dwelling w/gas FP 2996
s.f. By Order of Town Board
Garage 423 s.f. TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the
Direct u ding&Code En cement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000278-2017
Tax Map No: 308.7-1-69
Permission is hereby granted to: Hodorowski Homes
For property located at: 58 RICHMOND HILL DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvce of Construction
Owner Name: Mission Builders,LLC Single Family-New $200,000.00
Owner Address: 796 Burdock ST Total Value $200,000.00
Schenectady,NY 12306
Contractor or Builder's Name/Address Electrical Inspection Agency
Hodorowski Homes
796 Burdeck ST
Schenectady,NY 12306
Plans&Specifications
Single Family Dwelling w/gas FP 2996 s.f.
Garage 423 s.f.
$1,562.65 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,June 8,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the exp/ii non date
Dated at the Town of nsb { / /Jhor a , e 8,2017
SIGNED BY: /� for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
Permit#: 7-q'6. 291'--
PRINCIPLE STRUCTURE PERMIT
APPLICATION Permit Fee:$
Torm ofQucensbun G.n
*Rec Fee:$
742 Bay Road,Queensbury,NY 12804 a ✓V
P:518-761-8256 www.aueensbury.net ( Invoice#: 18t5
�
Project Location: ,58 ?iC}tmtW1N
Tax Map ID #: 308. 7 – ( – (v 9 Subdivision Name:'U c er i rl
*TOWN BD.RESOLUTION 86.2013: $850 recreation fee for new dwelling units: single family,duplexes/two-family,
multiple family, apartments, condominiums,townhouses, and/or manufactured &modular homes, but not mobile
homes. This Is In addition to the permit fee(s). —�
CONTACT INFORMATION: D ('
Applicant: VAY 2 6 2317 D
Name(s): k orY1e5
Mailing Address, C/S/Z: t.u-
CeIlPhone: Lan&Dne: 5(e -/435
Email: 114 CD ho�L,t of��sk,arr��. Ctxri
Primary Owner(s):
Name(s): 0Jj'!5Z,(nn 3u�\c ec S
Mailing Address, C/S/Z: ?Q(. -�irc�}� SrhPntr Eo���r Ny 1a 30(0
Cell Phone:_�) Land Line:
Email: 90
1L` �n�rlocrnusk'�r�, n• Ccxr1
a Contractor(s):
Business Name: Nr)c1lbrot ,ask:\ HininieS
Contact Name(s): ?pfd C oy-t-rtc:%
Mailing Address, C/S/Z: IC16 'j?1urAe—K gt 5chenerAQA4 N4 123ao
Cell Phone: (51FS ) 365- 91RO1 Land Line: (Kfg ) 3519 -1435
Email: go LA Q Q hrxIornl,�sk't a :0& n. c m
a Architect(s)/Engineer(s):
Business Name: NDmP \�eStg11 �r LLC
Contact Name(s): )rMrt V%al.mierc2-a Y-\
Mailing Address, C/S/Z: 35 Cklerrt Trej-- Lome- W i -Fon r)qy (A 8O3
Cell Phone: ( Land Line: _( .S 1 fir ) 16(o - ,5q5
Email: JV.n-y 1968 @ NICA0. PR Pram
Contact Person for Building & Code Compliance: 'len eoccadt
Cell Phone: _ (51 k ) 3G5- 01 Land Line:
Email: Deo C C5b Crxn
Town of Queensbury Building&Code Enforcement Principle structure Application Revised February 2017
PROJECT INFORMATION:
TYPE: Commercial f Residential
WORK CLASS:
Single-Family —Two-Family _Multi-Family(#of units )
Townhouse _Business Office _Retail _Hotel/Motel
Industrial/Warehouse _Garage (#of cars ) _Other(describe )
SQUARE FOOTAGE:
1st floor: 1619 -i'1'
2nd floor: 13'17 +1-
3rd floor:
4`h floor:
Total square feet: a q q to
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$ :2(y)
2.
f`Yln
2. Proposed use of the building: 9inI _ Fnm* 4 �t�cl in a
3. If Commercial or Industrial, indicate the name of the business:
4. Source of Heat (circle one): Gas Oil Propane Solar Other
Fireplaces need a separate Fuel Burning Appliances&Chimney Application,one per appliance
5. Are there any structures not shown on the plot plan? YES Explain:
6. Are there any easements on the property? YES
7. SITE INFORMATION:
a. What is the dimensions or acreage of the arcel? • 5 q ��"
b. Is this a corner lot? YES NO
c. Will the grade be changed as a result of the construction? YES NO
d. What is the water source? U PRIVATE WELL
e. Is the parcel on SEWER or RIVATE SEPTIC system?
Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017
DECLARATION:
1. I acknowledge that no construction shall commence prior to issuance of a valid building permit and
work will be completed within a 12 month period.
2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed 1, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-builtsurvey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: PCLJ UnAorox Ks
SIGNATURE: DATE: 111-7
Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017
FUEL BURNING APPLIANCE & office Use Onl
CHIMNEY APPLICATION Permit#: �-r-- — 2 j ' 0+
a Permit Fee:$
limn ul (gnrnebun
742 Bay Road, Queensbury, NY 12804 Invoice:#:
P: 518-761-8256 www.gueensbury.net
Project Location: (,-, PICM010AP, l tlwcTax Map ID 4:
Room of Install: i Planned Install Date:
**ONE APPLICATION PER APPLIANCE**
CONTACT INFORMATION: [V,A 2 6 2017 D
• Applicant TOWN OF QUEENSBURY
BUILDING R CODES
Mailing Address, C/S/Z: v 2 t
Cell Phone: Land Line: ( SI l ) 3 &0—
Email:
• Primary Owner(s):
Name(s):
Mailing Address, C/S/Z:
Cell Phone: _( ) Land Line: _( )
Email:
• Installer Bui der:
Business Name: (1 Orh — ,f "�
Piwf
Contact Name(s): 6 vV)tj—+
Mailing Address, C/S/Z:
Cell Phone: _( Land Line: _( )
Email:
Contact Person for Building & Code Compliance:
Cell Phone: ( ) Land Line: -( )
Email:
Fuel Burning Appliance &Chimney Application Revised March 2017
FUEL BURNING APPLIANCE INFORMATION:
TYPE OF DEVICE:
Stove Fireplace Insert Fireplace
Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3)
Fireplace, factory built**
(**Manufacturer's name: Model #: )
SOURCE OF HEAT:
Wood _ Coal _ Pellet Gas
CHIMNEY INFORMATION:
Masonry (require plans to be submitted):
block brick stone
_ Flue:
the _steel size, in inches
_Material*:
double-wall _triple-wall_insulated
(*Manufacturer's name: Le h C nx Model #: )
ADDITIONAL INFORMATION:
1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after
installation.
2. Manufacturer's installation manual must be available at the time of inspection.
3. Masonry fireplaces & chimneys require plans to be submitted.
4. Twenty-four (24) hour notification is required for inspections.
Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer
requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all
conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the
required inspections.
have read and9 agrr/eee to the above:
PRINT NAME: v A ✓'I
SIGNATURE:
�l U DATE: 2�
Fuel Burning A liance &Chimney Application Revised March 2017
SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only
742 Bay Road,Queensbury,NY 12804
no„n��nt�.,,�,n��' Permit#•
P:618-761-8256 www.aueensburv.net
Tax Map ID#: 308. 7- I - to 9 Permit Fee:$ : Invoice#:
Project Location: 58 '43;chmonc4 Hi115 lit'. Septic Variance? Yes No
PrimaryOwner(s) Msslmu��c�ErS
Mailing Address •••) G t NN 12304,
Phone& Email651h) 354 41Corn
Installer/Builder
Mailing Address -19 r S& la3 O(o
Phone&Email _I%
Engineer -D(.5rn 2k '
r
Mailing Address Sbiir IQ9044
Phone&Email 1 j J?'f
Contact Person for Building&Code Compliance: Corrag, Phone:�51 F) '3 C 5 g FO 7
RESIDENCE INFORMATION:
Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes No
1980 or older Installed? (circle one)
1981-1991 Spa or Hot Tub Yes No
Installed? (circle one)
1992-Present
PARCEL INFORMATION:
TopographyFlat Rolling —Steep Slope _%Slope
_
Soil Nature Sa _Loam _Clay _Other
Groundwater At what depth?
Bedrock/Impervious material At what depth?
Domestic Water Supply ✓ Municipal _Well(if well,water supply from any septic system absorption is_ft.)
Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION:
Tank size ► gallons(min.size 1,000 gallons,add 250 gallons for each garbage cylinder or spa/hot tub
System Absorption field with#2 stone Total length ft.; Each Trench Vo ft.
Seepage Pit with#3 stone How many: Size:
Alternative System Bed or other type:
Holding Tank System Total required capacity? ;tank size #of tanks
NOTES:1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection
agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved.
The installed system must match the septic layout on file—no exceptions.
Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material
representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I
have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage
Disposal Ordinance.
PRINT NAME: _9DATE: 5 1,29 11-7
SIGNATURE: DATE: S as
Town of Queensbury Building&code Enforcement Revised February 2017
Oc t. 16. 201711.2: 21 P MD IA. No. 0455 P. 4/6
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
V that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: Hodorowski Homes Date: 10/11/2017
Occupant: Same Location
58 Richmond Hill Drive �
Occupancy-Single Family Dwg. Queensbury, Warren Co. NY
Applicant
Global Electric _ - -
255 Osborne Rd Suite 4
Albany, N.Y. 12211
L it` _J
Joseph A.Holmes
No- - - ` - - - _1410321359369 EL.":.' l_
Equipment'
200-Amp. Service Equipment; 4/0-.Service-Conductor�S13 `SSnritcfies;T1=/Receptacles; 57 -Fixtures; 1 - Burner,
Wiring & Control; 1 -40 Amp-,Oven R6ceptacle; 1 -20 Amp Dishwasher Receptacle;..1-240 V/30 Amp Receptacle; 2 -
Vent Fans; 7-Smoke Detecto'to;.18 Ard,FauIt Breakers
This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and
above and the Installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership
inspection. No warranty is expressed or Implied as to the mechanical safety,of i- of the property indicated above,this certhcate shall be immediately null and void.
ciency or fitness of the equipment for any particular purpose. This certificate$hall In the event that this certificate becomes invalid based upon the above conditions,
be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department
system to which this certificate applies be uttered In any way,Including but not limit- Inspection Agency,Inc. An application for Inspectlen must be submitted to Mitltlle
ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc.to initiate the inspection and revalidatlon
any of the components installed as of the above noted date,this certificate shall be process, A fee will be charged for this service.
PCr v 2,0 V —
DC � no
HE0 E
U OCT 16 2017
TO
OBUit G P. CODES Y
Oct. 16. 20.17 1.2; 21PM M D I A No. 0455 P. 4/6
MIDDLE DEPARTMENT INSPECTION.AGENCY, INC.
that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: Hodorowski Homes Date: 10/11/2017
Occupant; Same Location
58 Richmond Hill Drive
Occupancy'-Single Family Dwg. Queensbury, Warren Co. NY
Applicant
Global Electric
255 Osborne Rd Suite 4 �.fj
--•, '� '-::
Albany N.Y. 12211 . E �• �. _." " .\
Joseph A.Holmes _..._ :•'- ..._......_. _.. _..... -
No- _1410321359369EL. _~
- - .- - - - - - - - - - - -, - - - - - - - - -
Equipment' :4
200-Amp_ Service Equipment; 4/0 Service-Condu6tor,-58-=`Snitches,-7-1- Recepta'etes; 57 Fixtures; 1 - Burner,
Wiring & Control; 1 -40 Amp-.Oven Receptacle; 1 -20 Amp Dishwasher Receptacle;..T-240 Wk Amp Receptacle; 2 -
Vent Fans; 7-Smoke Detecto'rs;,1'8Ar'&Fault Breakers
;,�� _;•1 ;may - 4�,'/ ,�,.
tea•,.. •'-. „t ,-. .
This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and
above and the Installation inspected as of the above noted date based on a visual ownershlo as indicated herein. Upon a change in the use,occupancy or ownership
inspection. No warranty is expressed or Implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void.
ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon ire above conditions,
be valid for a period of one year from the above noted date. Should the electrical this certificate may be eevalidatad upon reinspection by Middle Department
system to which this certificate applies be altered In any way,Including but not limit- Inspection Agency,Inc. An application for Inspection must be submitted to Middle
ad to,the introduction of additional electrical equipment and/or the replacement Of Department Inspection Agency, Inc. to initiate the inspection and revalldatlon
any of the components installed as of the above noted data,this certificate ahall be process, A fee will be charged for this service.
eC,--2�� 2,J0 V�-
OCT 16 2017
TOBt)NLD NG
P. CODES Y
Z-I
— Zoq
I"Ja HODOROWSKI
H O M E S tt �
BUILDING ON TRADITION
S��� L J 1 S►v�
2-
A ,
!4 34. 0 24. o
9 38• b 33•b
c qv. � 35. 0
c. d 5 5.fo -3s . (o
� S7, 0 3�• o
F 5y•
y c, 5`t. b y 4. o
bo
x 70. 0 SS .o
g5', b
o 34•
796 BURDECK STREET SCHENECTADY, NEW YORK 12306 PHONE: 518.356.1435 FAX 518.356.1447 WWW.HODOROWSK[HOMES.COM
4
NEWPORTI
NENTURES
Blower Door and Duct Leakage Test Report
Building Address ; a ('� Test Date l • �'�
Builder/Contractor t �S Time of Test
Phone
Email Indoor Temp. (F) 76
Outdoor Temp. (F)
Tester's Name Mat Ev Wind
Signature mo
House Type S'
ower Door❑Duct Leakage❑Measure Ventilation Floor Area (sq.ft.)
House Volume QyS�
Ring Used OPEN A B C
CFM@50 Pa y®
CFM 50* 60/Volume
2015 IECC minimum requirements:<_ACH 50(NYS Energy Code)
Results E ACH 50
2015 IECC )KPASS
Compliance ❑ FAIL
Duct Location ❑ Outside Building Thermal Envelope
❑ l uilding Thermal Envelope
Compliance ❑ Prescriptive eet specified leakage levels list ow)
Path ❑ Simulated Performan th(no is leakage level must be met)
❑ Energy Rating Index Co n it
(no specific leakage level must be met)
Ring Used OPEN A C
Prescriptive:The tat age shall be<_4CFM per 100 s re feet(air handler installed)
Prescriptive:Th otal leakage shall be 53CFM per 100 square fee 'r handler not installed)
Results CFM 25 ❑ PASS ❑ FAIL
DWELLING NUMBER OF BEDROOMS
UNIT
FLOOR 0- 1 2-3 4-5 6-7 >7
AREA
(square Airflow in CFM
Type of tiIation System ❑ Exhaust Only feet)
❑ Balanced < 1,500 30 45 60 75 90
1,501 - 45 60 75 90 105
Control Switches I a 3,000
Air Flow st System A CFM 34,500 60 75 90 los lao
Air Flow Exhaust System B CFM 4,501 - 75 90 105 120 135
6,000
6,001- 90 105 120 135 150
7,500
> 7,500 105 120 135 150 165
Newport Ventures 22 Jay Street Schenectady, NY 12305 518-377-9410
58 Richmond Hill Rd
HVAC Load Calculations
for
Hodorowski
t4 AY 2 6 2'V
I �
TOWN OF QUEENS?U i
L_ BUILI7iNG& C('': -
�
'X/A ReSID~ra'z'I[AL
�[ Pvc HVAC LOADS
308.7-1-69 RC-000278-2017
Hodorowski Homes
58 Richmond Hills Drive
SFD w/Gas FID 2996 s.f., Gar. 423 s.f.
Prepared By:
Nick Abrunza
Appolo Heating
Monday, May 22, 2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 58 Richmond Hill Rd
Schenectady 1 306 Page 2
PrO'eCt Report
General Pro'ect Information
Project Title: 58 Richmond Hill Rd
Project Date: Monday, May 22, 2017
Client Name: Hodorowski
Company Name: Appolo Heating
Company Representative: Nick Abrunza
Design Data
Reference City: Schenectady, New York
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 42 Degrees
Elevation: 378 ft.
Altitude Factor: 0.986
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Rnlin RPI HuD7 RPI Heim Dry But nifferenn
Winter: 1 0.31 n/a n/a 70 n/a
Summer: 87 72 49% 50% 75 30
r0fieck Figures
Total Building Supply CFM: 1,406 CFM Per Square ft.: 0.307
Square ft.of Room Area: 4,579 Square ft. Per Ton: 1,620
Volume (ft')of Cond. Space: 37,902
Building Loads
Total Heating Required Including Ventilation Air: 73,067 Btuh 73.067 MBH
Total Sensible Gain: 30,502 Btuh 90 %
Total Latent Gain: 3,412 Btuh 10 %
Total Cooling Required Including Ventilation Air: 33,914 Btuh 2.83 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance data at
your design conditions.
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Healing Inc. #` 58 Richmond Hill Rd
h ne NY 6Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb Wet Bulb Rel.Hum ReI.Hum Dry Bulb Difference
Winter: 1 0.31 80% n/a 70 n/a
Summer: 87 72 49% 50% 75 29.96
Duct Sizino Inouts
Main Trunk RunoutS
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
[OutsWe Air Data
Winter S i�mmer
Infiltration Specified: 0.370 AC/hr 0.190 AC/hr
234 CFM 120 CFM
Infiltration Actual: 0.370 AC/hr 0.190 AC/hr
Above Grade Volume: X 37,902 Cu.ft. X 37 .909 Cu.ft.
14,024 Cu.ft./hr 7,201 Cu.ft./hr
X 00167 X n.n167
Total Building Infiltration: 234 CFM 120 CFM
Total Building Ventilation: 0 CFM 0 CFM
—System 1---
Infiltration&Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference)
Infiltration&Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference)
Infiltration&Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.370 AC/hr(234 CFM), Construction:Average
Summer Infiltration Specified: 0.190 AC/hr(120 CFM), Construction:Average
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Y 12306 Page 4
Load Preview Re ort
Net ft' Sen Lat Net Sen His Sys
Act Duct
Scope Tan ?on Area Gain Gain Gain Lass CFM CFM CFM Size
Building 2.83 1,620 4,579 30,502 3,412 33,914 73,067 962 1,406 1,406
System 1 2.83 1,620 4,579 30,502 3,412 33,914 73,067 962 1,406 1,406 12x20
Zone 1 4,579 30,502 3,412 33,914 73,067 962 1,406 1,406 12x20
1-Basement 1,600 2,812 718 3,528 17,653 232 130 130 2-5
2-Library 155 1,417 127 1,544 3,638 48 65 65 1-5
3-Bath 1 45 783 35 818 1,032 14 36 36 1-4
4-Hall 50 411 0 411 385 5 19 19 1-4
5-Living Room 206 1,946 147 2,093 4,381 58 90 90 1-6
6-Foyer 162 1,359 72 1,431 2,749 36 63 83 1-5
7-Dining 210 1,956 149 2,105 4,434 58 90 90 1-6
8-Nook/Kitchen 347 2,195 109 2,304 5,578 73 101 101 1-6
9-Mud Room 44 969 73 1,042 1,633 21 45 45 1-4
10-Laundry 64 859 90 949 2,022 27 40 40 1-4
11-Bedroom 4 155 1,810 313 2,123 3,702 49 83 83 1--5
12-Bath 2 55 614 27 641 961 13 28 28 1-4
13-Bedroom 3 155 1,993 299 2,292 3,496 46 92 92 1-6
14-Open To Family 240 1,704 150 1,854 3,191 42 79 79 1-5
15-Loft 149 794 0 794 1,405 18 37 37 1-4
16-Open To Foyer 140 837 72 909 1,352 18 39 39 1-4
17-Bedroom 2 181 2,056 297 2,353 3,712 49 95 95 1-6
18-Master Suite 328 3,545 566 4,111 6,206 82 163 163 2-5
19-Master Bath 132 1,034 54 1,088 2,261 30 48 48 1-4
20-WIC 1 84 801 84 885 2,068 27 37 37 1-4
21-WIC 2 77 607 32 639 1,208 16 28 28 1-4
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
APpolo Heatinq Inc. 58 Richmond Hill Rd
Y 12306 Pace 5
Duct Size Preview
Room or Source Minimum Maximum Rough. Design SP Duct Duct Htg Clg Act. Duct
Duct Name Velocity Velocity Factor L/100 Loss Velocity Length
System 1
Supply Runouts
Zane 1
1-Basement Built-In 450 750 0 0.1 475.2 232 130 130 2-5
2-Library Built-In 450 750 0 0.1 478.8 48 65 65 1-5
3-Bath 1 Built-In 450 750 0 0.1 413.5 14 k_ 36. 36 1-4
4-Hall Built-In 450 750 0 0.1 216.8 5 JU 19 19 1-4
S-Living Room Built-In 450 750 0 0.1 456.8 58 WL 90 90 1-6
6-Foyer Built-In 450 750 0 0.1 459.4 36 63 83 1-5
7-Dining Built-In 450 750 0 0.1 458.9 58 90 90 1--6
8-Nook/Kitchen Built-In 450 750 0 0.1 515.3 73 101 101 1-6
94ud Room Built-In 450 750 0 0.1 511.7 21 45 45
10-Laundry Built-In 450 750 0 0.1 453.5 27 40 40 1-4
11-Bedroom 4 Built-In 450 750 0 0.1 611.7 49 83 83 1-5
12-Bath 2 Built-In 450 750 0 0.1 324.2 13 28 28 1--4
13-Bedroom 3 Built-In 450 750 0 0.1 467.8 46 92 92 1-6
14-Open To Family Built-In 450 750 0 0.1 575.9 42 79 79 1-5
15-Loft Built-In 450 750 0 0.1 419.3 18 37 37 1-4
16-Open To Foyer Built-In 450 750 0 0.1 441.8 18 39 39 1-4
17-Bedroom 2 Built-In 450 750 0 0.1 482.4 49 95 95 1-6
18-Master Suite Built-In 450 750 0 0.1 599.1 82 163 163 2-5
19-Master Bath Built-In 450 750 0 0.1 545.9 30 48 48 1-4
20-WIC 1 Built-In 450 750 0 0.1 423 27 37 37 1-4
21-WIC 2 Built-In 450 750 0 0.1 320.4 16 28 28 1-4
Other Ducts in System 1
Supply Main Tmnk Built-In 650 900 0 0.1 843.3 962 1.406 1,406 12x20
Summary
System 1
Heatinq Flow: 962
Coolinq Flow: 1406
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. � 58 Richmond Hill Rd
n N Page 6
Total Buildinq Summary Loads
Component Area Sen Lat Sen Total
Descriotion Quan Loss Gain Gain Gain
Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 302.9 6,479 0 4,643 4,643
Front Door: Door-Front Door 21 246 0 82 82
Pella Slider: Door-Pella Slider 40.8 1,323 0 441 441
Fire Rated: Door-Fire Rated 21 246 0 82 82
12C-Obm:Wall-Frame, R-13 insulation in 2 x 4 stud 1264 10,030 0 1,308 1,308
cavity, no board insulation, brick finish, metal studs
12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 2609.1 11,705 0 2,086 2,086
cavity, no board insulation, siding finish,wood studs
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1693.8 3,040 0 2,069 2,069
Floor(also use for Knee Walls and Partition
Ceilings),Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
21A-28: Floor-Basement, Concrete slab, any thickness, 2 1600 2,429 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 28'wide
19A-Ocp: Floor-Over enclosed unconditioned crawl 2257.9 17,265 0 3,003 3,003
space, No insulation on exposed walls, sealed or
vented space, passive, no floor insulation, carpet or
hardwood
19A-Otp: Floor-Over enclosed unconditioned crawl space, 339.5 2,805 0 487 487
No insulation on exposed walls,sealed or vented
space, passive no floor insulation tile or vinyl
Subtotals for structure: 55,568 0 14,201 14,201
People: 5 1,000 1,150 2,150
Equipment: 0 0 0
Lighting: 3930 13,401 13,401
Ductwork: 0 0 0 0
Infiltration:Winter CFM:234, Summer CFM: 120 17,499 2,412 1,562 3,974
Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Excursion: 0 0 187 187_
Total Building Load Totals: 73,067 3,412 30,502 33,914
Check Fi ures
Total Building Supply CFM: 1,406 CFM Per Square ft.: 0.307
Square ft. of Room Area: 4,579 Square ft. Per Ton: 1,620
Volume (ft')of Cond. Space: 37,902
Building Loads
Total Heating Required Including Ventilation Air: 73,067 Btuh 73.067 MBH
Total Sensible Gain: 30,502 Btuh 90 %
Total Latent Gain: 3,412 Btuh 10 %
Total Cooling Required Including Ventilation Air: 33,914 Btuh 2.83 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
c- esi en la ighi Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 58 Richmond Hill Rd
henectady NY 123Q6
Page 7
Building Pie Chart _
Infiltration 24%
Floor 31%
Door 2%
Glass 9%
Roof 4%
Wall 30%
°
AED Excursion 1%
Floor 10% Infiltration 12%
Roof 6%
Wall 10%
Glass 14% Lighting 40%
Door 2%
People 6%
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads ElitdiaLe Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady, Y 2
Detailed Room Loads - Room 1 - Basement (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 40.0 ft. System Number: 1
Room Width: 40.0 ft. Zone Number: 1
Area: 1,600.0 sq.ft. Supply Air: 130 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 0.6 AC/hr
Volume: 12,800.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 2 Actual Winter Vent.: 0 CFM
Runout Air: 65 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 475 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 475 ft./min. Actual Winter Infil.: 69 CFM
Actual Loss: 0.185 in.wg./100 ft. Actual Summer Infil.: 36 CFM
Item Area -U- Htg Sen CIg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N-Wall-12C-Obm 38 X 8 304 0.115 7.9 2,412 1.0 0 315
E-Wall-12C-Obm 40 X 8 320 0.115 7.9 2,539 1.0 0 331
S-Wall-12C-Obm 41 X 8 328 0.115 7.9 2,603 1.0 0 339
W-Wall-12C-0bm 39 X 8 312 0.115 7.9 2,476 1.0 0 323
Floor-21A-28 40 X 40 1600 0.022 1.5 2.429 0.0 0 0
Subtotals for Structure: 12,459 0 1,308
Infil.:Win.: 69.4, Sum.: 35.6 1,264 4.109 5,194 0.367 716 464
AED Excursion: 17
Lighting: 300 1,023
Room Totals: 17,653 716 2,812
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 56 Richmond Hill Rd
Schenectady,NY 12306 1W Page 9
Detailed Room Loads - Room 2 - Libra (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 155.0 sq.ft. Supply Air: 65 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.8 AC/hr
Volume: 1,393.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 65 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 479 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 479 ft./min. Actual Winter Infil.: 12 CFM
Actual Loss: 0.187 in.wg./100 ft. Actual Summer Infil.: 6 CFM
Fm Area -U- Htg Sen Clg Let Sen
scri tion uanti Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 12.9 X 9 84.9 0.065 4.5 381 0.8 0 68
W-Wall-12F-Osw 12 X 9 108 0.065 4.5 484 0.8 0 86
N-GIs-Pella Vinyl shgc-0.28 100%S 15.6 0.310 21.4 334 9.1 0 142
N-GIs-Pella Vinyl shgc-0.28 100%S 15.6 0.310 21.4 334 9.1 0 142
Floor-19A-Oco 12 X 12.9 154.8 0.295 7.6 1,184 1.3 0 206
Subtotals for Structure: 2,717 0 644
Infil.:Win.: 12.3, Sum.:6.3 224 4.110 921 0.366 127 82
AED Excursion: 9
Lighting: 200 682
Room Totals: 3,638 127 1,417
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectacv.
Detailed Room Loads - Room 3 - Bath 1 (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 6.6 ft. System Number: 1
Room Width: 6.8 ft. Zone Number: 1
Area: 45.0 sq.ft. Supply Air: 36 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 5.4 AC/hr
Volume: 404.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 36 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 413 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 413 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.192 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Let Sen
Descd tion Quantity Value HTM Loss HTM Gain Gain
W-Wall-12F-0sw 6.8 X 9 53.2 0.065 4.5 239 0.8 0 43
W-GIs-Pella Vinyl shgc-0.28 0%S 8 0.310 21.4 171 30.0 0 240
Floor-119A-Otp 6.8 X 6.6 44.9 0.368 8.3 371 1.4 0 64
Subtotals for Structure: 781 0 347
Infil.:Win.: 3.4, Sum.: 1.7 61 4.101 251 0.359 35 22
AED Excursion: 5
Lighting: 120 409
Room Totals: 1,032 35 783
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Healing Inc. 58 Richmond Hill Rd
Schenectady 12306 Page 11
Detailed Room Loads - Room 4 - Hall (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 7.1 ft. System Number: 1
Room Width: 7.1 ft. Zone Number: 1
Area: 50.0 sq.ft. Supply Air: 19 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.5 AC/hr
Volume: 454.0 cu.ft. Req.Vent. Cig: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 19 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 217 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 217 ft./min. Actual Winter Infil.: 0 CFM
Actual Loss: 0.054 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Fm Area -U- Htg Sen Clg Let Sen
scr tion Quantit Value HTM Loss HTM Gain Gain
Floor-19A-Ocp 7.1 X 7.1 50.4 0.295 7.6 385 1.3 0 67
Subtotals for Structure: 385 0 67
Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0
AED Excursion: 3
Lighting 100 341
Room Totals: 385 0 411
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 58 Richmond Hill Rd
YPage 12
Detailed Room Loads - Room 5 - Living Room (Average Load Procedure
General
Calculation Mode: Htg. &cig. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 16.0 ft. Zone Number: 1
Area: 206.0 sq.ft. Supply Air: 90 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.9 AC/hr
Volume: 1,858.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 90 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 457 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 457 ft./min. Actual Winter Infil.: 14 CFM
Actual Loss: 0.132 in.wg./100 ft. Actual Summer Infil.: 7 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S-Wall-12F-Osw 12.9 X 9 82.5 0.065 4.5 370 0.8 0 66
W-Wall-12F-0sw 16 X 9 144 0.065 4.5 646 0.8 0 115
S-GIs-Pella Vinyl shgc-0.28 0%S 16.8 0.310 21.4 359 15.8 0 266
S-GIs-Pella Vinyl shgc-0.28 0%S 16.8 0.310 21.4 359 15.8 0 266
Floor-19A-Ocp 16 X 12.9 206.4 0.295 7.6 __ 1.578 1.3 0 274
Subtotals for Structure: 3,312 0 987
Infil.:Win.: 14.3, Sum.:7.3 260 4.110 1,069 0.365 147 95
AED Excursion: 12
Lighting: 250 853
Room Totals: 4,381 147 1,946
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
ADPPIo Heatinq Inc. 58 Richmond Hill Rd
chenecta y NY 12306 Page
Detailed Room Loads - Room 6 - Foyer (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 10.1 ft. System Number: 1
Room Width: 16.0 ft. Zone Number: 1
Area: 162.0 sq.ft. Supply Air: 63 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.6 AC/hr
Volume: 1,454.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 63 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 459 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 459 ft./min. Actual Winter Infl.: 7 CFM
Actual Loss: 0.173 in.wg./100 ft. Actual Summer Inf I.: 4 CFM
Item Area -U- Htg Sen Cig Let Sen
Description uanti Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 2 X 9 18 0.065 4.5 81 0.8 0 14
S-Wall-12F-Osw 10.1 X 9 53.9 0.065 4.5 242 0.8 0 43
W-Wall-12F-Osw 2 X 9 18 0.065 4.5 81 0.8 0 14
S-Door-Front Door 3 X 7 21 0.170 11.7 246 3.9 0 82
S-GIs-Pella Vinyl shgc-0.28 0%S 8 0.310 21.4 171 15.9 0 127
S-GIs-Pella Vinyl shgo-0.28 0%S 8 0.310 21.4 171 15.9 0 127
Floor-19A-Ocp 16 X 10.1 161.6 0.295 7.6 1,236 1.3 0 215
Subtotals for Structure: 2,228 0 622
Infil.:Win.: 7.0, Sum.: 3.6 127 4.106 521 0.370 72 47
AED Excursion: 8
Lighting: 200 _ 682
Room Totals: 2,749 72 1,359
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads ® Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectadv. NY 12306 Paae 14
Detailed Room Loads - Room 7 - Dining (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 16.3 ft. Zone Number: 1
Area: 210.0 sq.ft. Supply Air: 90 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.9 AC/hr
Volume: 1,892.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 90 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 459 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 459 ft./min. Actual Winter Infil.: 14 CFM
Actual Loss: 0.134 in.wg./100 ft. Actual Summer Infil.: 7 CFM
Fm Area -U- Htg Sen Clg Lat Sen
scri tion uanti Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 16.3 X 9 146.7 0.065 4.5 658 0.8 0 117
S-Wall-12F-Osw 12.9 X 9 82.5 0.065 4.5 370 0.8 0 66
S-GIs-Pella Vinyl shgc-0.28 0%S 16.8 0.310 21.4 359 15.8 0 266
S-GIs-Pella Vinyl shgc-0.28 0%S 16.8 0.310 21.4 359 15.8 0 266
Floor-119A-Oco 16.3 X 12.9 210.3 0.295 7.6 1,608 1.3 0 280
Subtotals for Structure: 3,354 0 995
Infil.:Win.: 14.4, Sum.: 7.4 263 4.110 1,080 0.365 149 96
AED Excursion: 12
Lighting: 250 853
Room Totals: 4,434 149 1,956
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady, NY 12306 Paae 15
Detailed Room Loads - Room 8 - Nook/Kitchen (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 20.3 ft. System Number: 1
Room Width: 17.1 ft. Zone Number: 1
Area: 347.0 sq.ft. Supply Air: 101 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.9 AC/hr
Volume: 3,124.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 101 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 515 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 515 ft./min. Actual Winter Infil.: 11 CFM
Actual Loss: 0.168 in.wg./100 ft. Actual Summer Infil.: 5 CFM
Fm Area -U- Htg Sen Clg Let Sen
scri tion uanti Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 21.3 X 9 142.9 0.065 4.5 641 0.8 0 114
N-Door-Pella Slider 6 X 6.8 40.8 0.470 32.4 1,323 10.8 0 441
N-GIs-Pella Vinyl shgc-0.28 100%S 4 0.310 21.4 86 9.0 0 36
N-GIs-Pella Vinyl shgc-0.28 100%S 4 0.310 21.4 86 9.0 0 36
Floor-19A-0co 17.1 X 20.3 347.1 0.295 7.6 2,654 1.3 0 462
Subtotals for Structure: 4,790 0 1,089
Infil.:Win.: 10.5, Sum.: 5.4 192 4.111 788 0.365 109 70
AED Excursion: 13
Lighting: 300 1,023
Room Totals: 5,578 109 2,195
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
ADpolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady NY 12306 Page 16
Detailed Room Loads - Room 9 - Mud Room (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 6.0 ft. System Number: 1
Room Width: 7.4 ft. Zone Number: 1
Area: 44.0 sq.ft. Supply Air: 45 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 6.7 AC/hr
Volume: 400.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 45 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 512 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 512 ft./min. Actual Winter Infil.: 7 CFM
Actual Loss: 0.292 in.wg./100 ft. Actual Summer Infil.: 4 CFM
Item Area -U- Htg Sen Gig Let Sen
Desch tion uanti .Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 7.4 X 9 66.6 0.065 4.5 299 0.8 0 53
S-Wall-12F-Osw 7 X 9 42 0.065 4.5 188 0.8 0 34
S-Door-Fire Rated 3 X 7 21 0.170 11.7 246 3.9 0 82
Floor-19A-Otp 7.4 X 6 44.4 0.368 8.3 367 1.4 0 64
Subtotals for Structure: 1,100 0 233
Infil.:Wn.: 7.1, Sum.: 3.7 130 4.113 533 0.370 73 48
AED Excursion: 6
Lighting: 200 682
Room Totals: 1,633 73 969
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
NY 12306 Pae 17
Detailed Room Loads - Room 10 - Laundry (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 6.0 ft. System Number: 1
Room Width: 10.6 ft. Zone Number: 1
Area: 64.0 sq.ft. Supply Air: 40 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 4.2 AC/hr
Volume: 572.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 40 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 453 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 453 ft./min. Actual Winter Infil.: 9 CFM
Actual Loss: 0.230 in.wg./100 ft. Actual Summer Infil.: 4 CFM
Item Area -U- Htg Sen Clg Let Sen
Description Quantity Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 7 X 9 55 0.065 4.5 247 0.8 0 44
E-Wall-12F-Osw 10.6 X 9 95.4 0.065 4.5 428 0.8 0 76
N-GIs-Pella Vinyl shgc-0.28 100%S 8 0.310 21.4 171 9.1 0 73
Floor-19A-Otp 10.6 X 6 63.6 0.368 8.3 525 1.4 0 91
Subtotals for Structure: 1,371 0 284
Infil.:Win.: 8.7, Sum.:4.5 158 4.110 651 0.366 90 58
AED Excursion: 5
Lighting: 150 512
Room Totals: 2,022 90 859
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential S Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 58 Richmond Hill Rd
Y 123061
Detailed Room Loads - Room 11 - Bedroom 4 Avera e Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 155.0 sq.ft. Supply Air: 83 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 4.0 AC/hr
Volume: 1,238.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 83 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 612 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 612 ft./min. Actual Winter Infil.: 11 CFM
Actual Loss: 0.304 in.wg./100 ft. Actual Summer Infil.: 6 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value _ HTM Loss HTM_ Gain Gain
N-Wall-12F-Osw 12.9 X 8 72 0.065 4.5 323 0.8 0 58
W-Wall-12F-Osw 12 X 8 96 0.065 4.5 431 0.8 0 77
N-GIs-Pella Vinyl shgc-0.28 100%S 15.6 0.310 21.4 334 9.1 0 142
N-GIs-Pella Vinyl shgc-0.28 100%S 15.6 0.310 21.4 334 9.1 0 142
UP-Ceil-16B-3812.9 X 12 154.8 0.026 1.8 278 1.2 0 189
Floor-19A-Ocp 12 X 12.9 154.8 0.295 7.6 1,184 1.3 0 206
Subtotals for Structure: 2,884 0 814
Infil.:Win.: 10.9,Sum.: 5.6 199 4.106 818 0.366 113 73
AED Excursion: 11
People:200 lat/per,230 sen/per: 1 200 230
Lighting: 200 682
Room Totals: 3,702 313 1,810
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
ADPolo Healinq Inc. 58 Richmond Hill Rd
Schenectadv.NY 12306 Eage 19
Detailed Room Loads - Room 12 - Bath 2 (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 9.1 ft. System Number: 1
Room Width: 6.0 ft. Zone Number: 1
Area: 55.0 sq.ft. Supply Air. 28 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 3.9 AC/hr
Volume: 437.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 28 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 324 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 324 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.119 in.wg./100 ft. Actual Summer Infil.: 1 CFM
Item Area -U- Htg Sen Clg Lat Sen
Descri tion uanti Value HTM Loss HTM Gain Gain
W-Wall-12F-Osw 6 X 8 48 0.065 4.5 215 0.8 0 38
UP-Ceil-16B-38 9.1 X 6 54.6 0.026 1.8 98 1.2 0 67
Floor-19A-Otp 6 X 9.1 54.6 0.368 8.3 451 1.4 0 78
Subtotals for Structure: 764 0 183
Infil.: Win.:2.6, Sum.: 1.4 48 4.104 197 0.375 27 18
AED Excursion: 4
Lighting: 120 409
Room Totals: 961 27 614
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 91110011 58 Richmond Hill Rd
Srhenectady.NY 12 P3g2
Detailed Room Loads - Room 13 - Bedroom 3 (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 155.0 sq.ft. Supply Air: 92 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 4.5 AC/hr
Volume: 1,238.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 92 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 468 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 468 ft./min. Actual Winter Infil.: 10 CFM
Actual Loss: 0.139 in.wg./100 ft. Actual Summer Infil.: 5 CFM
Item Area -U- Htg Sen Cig Lat Sen
Description Quantity Value HTM Loss HTM Gain _ Gain
E-Wall-12F-Osw 9 X 8 72 0.065 4.5 323 0.8 0 58
S-Wall-12F-Osw 12.9 X 8 72 0.065 4.5 323 0.8 0 58
S-GIs-Pella Vinyl shgc-0.28 0%S 15.6 0.310 21.4 334 15.8 0 247
S-GIs-Pella Vinyl shgc-0.28 0%S 15.6 0.310 21.4 334 15.8 0 247
UP-Ceil-16B-38 12.9 X 12 154.8 0.026 1.8 278 1.2 0 189
Floor-19A-0cp 12 X 12.9 154.8 0.295 7.6 1,184 1.3 0 206
Subtotals for Structure: 2,776 0 1,005
Iri Win.: 9.6, Sum.:4.9 175 4.110 720 0.365 99 64
AED Excursion: 12
People: 200 Iat/per, 230 sen/per: 1 200 230
Lighting: 200 682
Room Totals: 3,496 299 1,993
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady,NY 12306 pare 21
Detailed Room Loads - Room 14 - Open To Family (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 16.0 ft. System Number: 1
Room Width: 15.0 ft. Zone Number: 1
Area: 240.0 sq.ft. Supply Air: 79 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.5 AC/hr
Volume: 1,920.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 79 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 576 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 576 ft./min. Actual Winter Infil.: 14 CFM
Actual Loss: 0.270 in.wg./100 ft. Actual Summer Infil.: 7 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 17 X 8 106.9 0.065 4.5 479 0.8 0 85
E-Wall-12F-Osw 8 X 8 64 0.065 4.5 287 0.8 0 51
W-Wall-12F-Osw 8 X 8 64 0.065 4.5 287 0.8 0 51
N-GIs-Pella Vinyl shgo-0.28 100%S 14.6 0.310 21.4 311 9.1 0 132
N-GIs-Pella Vinyl shgc-0.28100%S 14.6 0.310 21.4 311 9.1 0 132
UP-Ceil-1 6B-38 16 X 15 240 0.026 1.8 431 1.2 0 293
Subtotals for Structure: 2,106 0 744
Infil.:Win.: 14.5,Sum.: 7.4 264 4.110 1,085 0.367 150 97
AED Excursion: 10
Lighting: 250 853
Room Totals: 3,191 150 1,704
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 49& 58 Richmond Hill Rd
Schenectaciv.NY 12306 ���A777T"' Page 22
Detailed Room Loads - Room 15 - Loft (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.2 ft. System Number: 1
Room Width: 12.2 ft. Zone Number: 1
Area: 149.0 sq.ft. Supply Air: 37 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 1.8 AC/hr
Volume: 1,191.0 cu.ft. Req.Vent. CIg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 37 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 419 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 419 ft./min. Actual Winter Infil.: 0 CFM
Actual Loss: 0.197 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Fm Area -U- Htg Sen Clg Lat Sen
Description tion uantit Value HTM Loss HTM Gain Gain
UP-Ceil-16B-38 12.2 X 12.2 148.8 0.026 1.8 267 1.2 0 182
Floor-19A-Ocp 12.2 X 12.2 148.8 0.295 7.6 1,138______1_3_ 0 198
Subtotals for Structure: 1,405 0 380
Infil.:Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0
AED Excursion: 5
Lighting: 120 _ 409
Room Totals: 1,405 0 794
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC LoadsElite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady, �R� Peae 23
Detailed Room Loads - Room 16 - Open To Foyer (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 10.0 ft. System Number: 1
Room Width: 14.0 ft. Zone Number: 1
Area: 140.0 sq.ft. Supply Air: 39 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.1 AC/hr
Volume: 1,120.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 39 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 442 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 442 ft./min. Actual Winter Infil.: 7 CFM
Actual Loss: 0.219 in.wg./100 ft. Actual Summer Infil.: 4 CFM
Item Area -U- Htg Sen Clg Lat Sen
Desai tion Quantity Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 3 X 8 24 0.065 4.5 108 0.8 0 19
S-Wall-12F-0sw 10 X 8 80 0.065 4.5 359 0.8 0 64
W-Wall-12F-0sw 3 X 8 24 0.065 4.5 108 0.8 0 19
UP-Ceil-16B-38 10 X 14 140 0.026 1.8 251 12 0 171
Subtotals for Structure: 826 0 273
Infil.:Win.: 7.0, Sum.:3.6 128 4.109 526 0.367 72 47
AED Excursion: 5
Lighting 150 512
Room Totals: 1,352 72 837
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Healinq Inc. 58 Richmond Hill Rd
Schenectady 12306 Page
Detailed Room Loads - Room 17 - Bedroom 2 (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.9 ft. System Number: 1
Room Width: 14.0 ft. Zone Number: 1
Area: 181.0 sq.ft. Supply Air: 95 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 3.9 AC/hr
Volume: 1,445.0 cu.ft. Req.Vent.Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 95 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 482 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 482 ft./min. Actual Winter Infil.: 9 CFM
Actual Loss: 0.148 in.wg./100 ft. Actual Summer Infil.: 5 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 8.6 X 8 68.8 0.065 4.5 309 0.8 0 55
S-Wall-12F-Osw 12.9 X 8 72 0.065 4.5 323 0.8 0 58
S-GIs-Pella Vinyl shgo-0.28 0%S 15.6 0.310 21.4 334 15.8 0 247
S-GIs-Pella Vinyl shgo-0.28 0%S 15.6 0.310 21.4 334 15.8 0 247
UP-Ceil-168-38 12.9 X 14 180.6 0.026 1.8 324 1.2 0 221
Floor-119A-Ocp 14 X 12.9 180.6 0.295 7.6 1,381 1.3 0 240
Subtotals for Structure: 3,005 0 1,068
Infil.:Win.: 9.4, Sum.:4.8 172 4.110 707 0.366 97 63
AED Excursion: 13
People: 200 Iat/per, 230 sen/per: 1 200 230
Lightingz 200 682
Room Totals: 3,712 297 2,056
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 49& 58 Richmond Hill Rd
Schenectady,NY 12306 Page 2
Detailed Room Loads - Room 18 - Master Suite (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 21.0 ft. System Number: 1
Room Width: 15.6 ft. Zone Number: 1
Area: 328.0 sq.ft. Supply Air: 163 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 3.7 AC/hr
Volume: 2,621.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 2 Actual Winter Vent.: 0 CFM
Runout Air: 82 CFM Percent of Supply.: 0 %
Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 599 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 599 ft./min. Actual Wiinterinfil.: 16 CFM
Actual Loss: 0.291 in.wg./100 ft. Actual Summer Infil.: 8 CFM
Fm Area -U- Htg Sen Cig Lat Sen
scri tion uantit Value HTM Loss HTM Gain Gain
E-Wall-12F-Osw 15.6 X 8 89.4 0.065 4.5 401 0.8 0 72
S-Wall-12F-Osw 21 X 8 168 0.065 4.5 753 0.8 0 134
E-GIs-Pella Vinyl shgc-0.28 0%S 17.7 0.310 21.4 378 30.0 0 531
E-GIs-Pella Vinyl shgc-0.28 0%S 17.7 0.310 21.4 378 30.0 0 531
UP-Ceil-16B-38 21 X 15.6 327.6 0.026 1.8 588 1.2 0 400
Floor-19A-Ocp 15.6 X 21 327.6 0.295 7.6 2,505 1.3 0 436
Subtotals for Structure: 5,003 0 2,104
Infil.:Win.: 16.1,Sum.: 8.3 293 4.109 1,203 0.365 166 107
AED Excursion: 22
People:200 lat/per, 230 sen/per: 2 400 460
Lighting: 250 853
Room Totals: 6,206 566 3,545
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
Schenectady NY 12306 Page 2
Detailed Room Loads - Room 19 - Master Bath (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.0 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 132.0 sq.ft. Supply Air: 48 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr
Volume: 1,056.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 48 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 546 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 546 ft./min. Actual Winter Infil.: 5 CFM
Actual Loss: 0.332 in.wg./100 ft. Actual Summer Infil.: 3 CFM
Item Area -U- Htg Sen CIg Lat Sen
Description QuantityValue HTM Loss HTM Gain Gain
N-Wall-12F-Osw 12 X 8 89.6 0.065 4.5 402 0.8 0 72
N-GIs-Pella Vinyl shgc-0.28 100%S 6.4 0.310 21.4 137 9.1 0 58
UP-Ceil-16B-38 12 X 11 132 0.026 1.8 237 1.2 0 161
Floor-19A-0tp 11 X 12 132 0.368 8.3 1,091 _ 1.4 0 190
Subtotals for Structure: 1,867 0 481
Infil.:Win.: 5.3, Sum.:2.7 96 4.104 394 0.365 54 35
AED Excursion: 6
Lighting: 150 512
Room Totals: 2,261 54 1,034
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads dz& Elite Software Development,Inc.
Appolo Heating Inc. 58 Richmond Hill Rd
Schenectady.NY 12306 1W Page 2Z
Detailed Room Loads - Room 20 - WIC 1 (Average Load Procedure
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 7.6 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 84.0 sq.ft. Supply Air: 37 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 3.3 AC/hr
Volume: 669.0 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 37 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 423 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 423 ft./min. Actual Winter Infil.: 8 CFM
Actual Loss: 0.201 in.wg./100 ft. Actual Summer Infil.: 4 CFM
FItem Area -U- Htg Sen Clg Lat Sen
tion uanti Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 7.6 X 8 60.8 0.065 4.5 273 0.8 0 49
E-Wall-12F-Osw 11 X 8 88 0.065 4.5 395 0.8 0 70
UP-Ceil-16B-38 7.6 X 11 83.6 0.026 1.8 150 1.2 0 102
Floor-19A-Ocp 11 X 7.6 83.6 0.295 7.6 639 1.3 0 111
Subtotals for Structure: 1,457 0 332
Infil.:Win.: 8.2, Sum.:4.2 149 4.106 611 0.370 84 55
AED Excursion: 5
Lighting: 120 409
Room Totals: 2,068 84 801
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
ScbenWady. NY 12306 V Page 28
Detailed Room Loads - Room 21 - WIC 2 (Average Load Procedure
I.General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 7.0 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 77.0 sq.ft. Supply Air: 28 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr
Volume: 616.0 cu.ft. Req.Vent.Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 28 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 320 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 320 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.116 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Descri tion uantit Value HTM Loss HTM Gain Gain
N-Wall-12F-Osw 7 X 8 56 0.065 4.5 251 0.8 0 45
UP-Ceil-16B-38 7 X 11 77 0.026 1.8 138 1.2 0 94
Floor-19A-0cp 11 X 7 77 0.295 7.6 589 1.3 0 102
Subtotals for Structure: 978 0 241
Infil.:Win.: 3.1, Sum.: 1.6 56 4.107 230 0.375 32 21
AED Excursion: 4
Lightinw 100 341
Room Totals: 1,208 32 607
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22,2017, 12:38 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heatinq Inc. 58 Richmond Hill Rd
NY 12306 Page 291
S stem 1 Room Load Summa
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
--Zone 1--
1 Basement 1,600 17,653 232 2-5 475 2,812 716 130 130
2 Library 155 3,638 48 1-5 479 1,417 127 65 65
3 Bath 45 1,032 14 1-4 413 783 35 36 36
4 Hall 50 385 5 1-4 217 411 0 19 19
5 Living Room 206 4,381 58 1-6 457 1,946 147 90 90
6 Foyer 162 2,749 36 1-5 459 1,359 72 63 63
7 Dining 210 4,434 58 1-6 459 1,956 149 90 90
8 Nook/Kitchen 347 5,578 73 1-6 515 2,195 109 101 101
9 Mud Room 44 1,633 21 1-4 512 969 73 45 45
10 Laundry 64 2,022 27 1-4 453 859 90 40 40
11 Bedroom 155 3,702 49 1-5 612 1,810 313 83 83
12 Bath 2 55 961 13 1-4 324 614 27 28 28
13 Bedroom 3 155 3,496 46 1-6 468 1,993 299 92 92
14 Open To Family 240 3,191 42 1-5 576 1,704 150 79 79
15 Loft 149 1,405 18 1-4 419 794 0 37 37
16 Open To Foyer 140 1,352 18 1-4 442 837 72 39 39
17 Bedroom 2 181 3,712 49 1-6 482 2,056 297 95 95
18 Master Suite 328 6,206 82 2-5 599 3,545 566 163 163
19 Master Bath 132 2,261 30 1-4 546 1,034 54 48 48
20 WIC 1 84 2,068 27 1-4 423 801 84 37 37
21 WIC 2 77 1,208 16 1-4 320 607 32 28 28
System 1 total 4,579 73,067 962 30,502 3.412 1,406 1.406
System 1 Main Trunk Size: 12x20 in.
Velocity: 843 ft./min
Loss per 100 ft.: 0.093 in.wg
Coolin-q System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons split Btuh Btuh Btuh
Net Required: 2.83 90%/10% 30,502 3,412 33,914
Actual: 3.42 75%/25% 30,750 10,250 41,000
Equipment Data
Heating System Coolinq System
Type: Natural Gas Furnace Standard Air Conditioner
Model: M1_195UH090XP48C-* 13ACXN042-230-*
Indoor Model: C35-30/368+TDR+TXV
Brand: MERIT 90 LENNOX
Description: Natural Gas or Propane Furnace
Efficiency: 95 AFUE 13.5 SEER
Sound: 0 0
Capacity: 85,000 Btuh 41,000 Btuh
Sensible Capacity: n/a 30,750 Btuh
Latent Capacity: n/a 10,250 Btuh
AHRI Reference No.: n/a 8269502
C:\Users\Nicholas\Documents\Elite Software\Rhvac 9 Projects\58 Richmond Hill Dr.rh9 Monday, May 22, 2017, 12:38 PM
e
CREScheck Software Version 4.6.4
�(J Compliance Certificate
Project Country Manor
Energy Code: 2015 IECC Ll
Location: Glens Falls, New YorkConstruction Type: Single-family Project Type: New Construction
Conditioned Floor Area: 2,996 ft2
Glazing Area 11%Climate Zone: 6 (7635 NDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
58 Richmond Hills Drive Hodorowski Homes Northstar Home Design,LLC
Queensbury, NY
:Compliance: Passes using UA trade-off
Compliance: 1.4%Better Than Code Maximum UA: 418 Your UA: 412
The%Better or Worse Than Code Index reflects how dose to compliance the house is based an code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Assembly or Cavity Cont. U-Factor UA
Ceiling 1: Raised or Energy Truss 1,861 49.0 0.0 0.020 37
Wall 1:Wood Frame, 16"D.C. 3,648 21.0 0.0 0.057 183
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 351 0.300 105
Door 1:Glass 40 0.300 12
Door 2:Solid 51 0.190 10
Basement Wall 1: Solid Concrete or Masonry 1,536 19.0 5.0 0.037 57
Wall height:8.0'
Depth below grade:7.0'
Insulation depth: 8.0'
Floor 2:All-Wood jolstrrruss:Over Unconditioned Space 242 30.0 0.0 0.033 8
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
ON
Name-Title Signature S.�PEDI,yg9 q� Date
308.7-1-69 RC-000278-2017
Hodorowski Homes y _ z
58 Richmond Hills Drive aq 046720
SFD w/Gas FP 2996 s.f., Gar. 423 s.f. esS1
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users\iohn Kaz\Desktop\ResChecks\58 Richmond Hills C rive.rck Page 1 of 9
A
REScheck Software Version 4.6.4
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
&Req.ID
103.1, :Construction drawings and OComplies
103.2 documentation demonstrate ❑Does Not
[PRI]' energy code compliance for the
d building envelope.Thermal []Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, ;documentation demonstrate ❑Does Not
403.7
j energy code compliance for ❑Not Observable
[PR3] ;lighting and mechanical systems.
0: �systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr— Btu/hr ',❑Does Not
[PR2]2 ,on loads calculated per ACCA Cooling: Cooling: ;❑Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. IONot Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users)john Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 2 of 9
' Section plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1 Conditioned basement wall ; R-_ R-_ ❑Complies ISee the Envelope Assemblies
insulation
[FO471 insulation Is used,
used,,verification where interior' R_ R- ❑Does Not !table for values.
❑Not Observable
- may need to occur during
Insulation Inspection.Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall []Complies
[FO511 insulation installed per ❑Does Not
y, manufacturer's Instructions. ❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO611 insulation depth of burial or ❑Does Not table for values.
u. distance from top of wall. ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
,14, insulation and extends a []Not Observable
minimum of 6 in.below grade.
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12]2 controls installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
I I High Impact[Tier 1) 2 Medium Impact[Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\UsersVohn Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 3 of 9
' Section Plans Verified Field Verified
# Framing/ Rough-In Inspection
&Req.ID Value Value Complies? Comments/Assumptions
402.1.1, :Door U-factor. I U-_ U-_ ❑Complies 'See the Envelope Assemblies
402.3.4 I
❑Does Not table for values.
[FRl]1 I []Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U-_ U__ ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2J1
N'
303.1.3 U-factors of fenestration products' ❑Complies
[FR4]1 :are determined in accordance ❑Does Not
O with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's []Does Not
'.instructions.
[]Not Observable
❑Not Applicable
402.4.3 !Fenestration that is not site built ❑Complies
[FR2011 -is listed and labeled as meeting ❑Does Not
�AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable
or has infiltration rates per NFRC
'400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate s2.0 cfm ❑Not Observable
leakage at 75 Pa. ❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated>=R-8 where duct is ❑Does Not
;�. >= 3 inches in diameter and >_ ❑Not Observable
R-6 where< 3 inches.Supply and:
return ducts in other portions of ❑Not Applicable j
the building insulated>=R-6 for
diameter>=3 inches and R-4.2
for<3 inches in diameter.
403.3.3.5 Building cavities are not used as -❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable j
403.4 HVAC piping conveying fluids R-_ R-_ ❑Complies
[FR17]2 above 105 OF or chilled fluids ❑Does Not
1, below 55 OF are insulated to aR- j
3 ;❑Not Observable
❑Not Applicable
403.4.1 ;Protection of insulation on HVAC. ❑Complies
[FR24]1 :piping. ! ❑Does Not
9 ❑Not Observable I
❑Not Applicable j
403.5.3 Hot water pipes are insulated to R-_ R-_ ❑Complies
[FR1872 >_R-3. ;❑Does Not
1❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are,; ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users�ohn Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 4 of 9
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\UsersVohn Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 5 of 9
Section Plans Verified Field Verified# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.1D
303.1 All installed insulation is labeled ❑Complies
[IN13]1 or the installed R-values ❑Does Not
0, .provided.
[]Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not 'table for values.
[INl]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]' in substantial contact with the
_ underside of the subfloor, or floor ❑Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value.If this is a R-_ R-_ ❑Complies ISee the Envelope Assemblies
402.2.5, mass wall with at least 1h of the !,❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 ;wall insulation on the wall ❑ Mass j❑ Mass ❑Not Observable
[IN3]1 :exterior,the exterior insulation Steel j E] Steel y.
!requirement applies(FR10). ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
[]Not Observable
❑NotAppiicabie
Additional Comments/Assumptions:
11 High Impact(Ter 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users)john Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 6 of 9
' -Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, Ceiling insulation R-value. R- R- I❑Complies j5ee the Envelope Assemblies
402.2.1, ❑ Wood ❑ Woad ❑Does Not :table for values.
402.22• ❑ steel ❑ Steel ;❑Not Observable
402.2.6
[FI111 ;❑Not Applicable
303.1.1.1, .Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI211 Blown insulation marked every
.300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[F12212 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R-_ R-_ ❑Complies
[9311 insulation all-value of the j❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable j
402.4.1.2 Blower door test @ 50 Pa.<=5 ACH 50 =_ ACH 50=_ ❑Complies
[FI17]1 ach in Climate Zones 1-2, and []Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/loo ❑Complies
[F14]1 cfm/100 ft2 across the system or ft' j ft2 j❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa.For rough-in ❑Not Observable
tests,verification may need to I❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F12711 determine air leakage with ; ftz ft2 1ODoes Not
either:Rough-in test:Total I
❑Not Observable
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test.Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
j handler enclosure.
403.3.2.1 'Air handler leakage designated ❑Complies
[FI24]1 ;by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable 1
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F1912 installed for control of primary []Does Not
heating and cooling systems and
initially set by manufacturer to []Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[Ff1012 on heat pumps. []Does Not
❑Not Observable
❑Not Applicable j
403.5.1 Circulating service hot water ❑Complies
[Fl11]2 'systems have automatic or ❑Does Not
accessible manual controls. ❑Nat Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users)john Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 7 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions
& Re .ID I
Value Value Complies? Comments/Assumptions
403.6.1 All mechanical ventilation system ❑Complies
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. []Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
IFI2612 :through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water []Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 :Heated water circulation systems ❑Complies
IF12812 have a circulation pump.The ❑Does Not
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply.
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
(FI2912 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically
adjust the energy input to the []Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that [ Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold ❑Nat Applicable j
water supply pipe have a
demand recirculation water
system.Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold -
water piping to 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 'tested in accordance with CSA ❑Does Not
855.1.Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units<3 psi for ❑Not Applicable
individual units connected to one
or two showers.Potable water-
side pressure loss of drain water
heat recovery units<2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F161' fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. ❑Not Observable
Does not apply to low-voltage
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F12313 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable j
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users)(ohn Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 8 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies
[F17]2 []Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI18)3 mechanical and water heating ❑Does Not
systems have been provided. []Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier3)
Project Title: Country Manor Report date: 05/10/17
Data filename: C:\Users)john Kaz\Desktop\ResChecks\58 Richmond Hills Drive.rck Page 9 of 9
2015 IECC Energy
Efficiency Certificate
In! R-Value
Above-Grade Wall 21.00
Below-Grade Wall 24.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass & Door Rating U-Factor SHGC
Window 0.30
Door 0.19
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
Map Reference: PERMIT PLOT PLAN
I HAVE PERSONAL_ LY MEASURED THE DISTANCE -6
Subdivision Modification ar_ r�r i�� TO THE
Subdivision Plan F R�''Vl TFC'= Of�R'�' LINES
Thomas Schiavone F'FZ' GS'tG IJC IJ -`S)OR`''GN ) Lot 27 a
Dated: January 09, 2003 ��• �! '2
Last Revised: December 17, 2009 pT z a
Si, tv 'TUP.E
By: Nace Engineering P.C. and a W �
Van Dusen & Steves Land Surveyors ¢ o a
O T U
O W
O lWil O
� W
Lot 2
3 81° lb
17'00 E NVQ
_ 200. 00
U
ack wv I
I o PrOP°sed
At
Driveway r
Z
dM
U 42.00'
o _ Lot 22 a Z
o v o o ►y oC °
o CF)I Area N I o x
+� 4 k
; 25,000± Sq. Feet o N 4 0 ;)A
Co I 0.57± Acres 4.00' Prop°sed o0 72.0' "� ao �� I a
Q) r►� °
2.oa m "Ouse o co I O o
= I m o \ 10 o
Lot 20 2.00' i.00 4.00' , 0
C? i.00
{� ai o .00'
BlI L f 33.01'
('4Aav 26 213175 J !
T 01AIN'GE QUE:Ef` SSU R`r` P(y�1 s
".:'.�. )H�:'.�.�. ^c i ut+�J
L120Q QO
o �y Lot 3 "
0
Lot 23
z
F� a z
A�Q)
NOTE: BASEMENT FLOOR ELEVATIONS AND BOTTOM OF LEACH FIELD TRENCH Lot No. 22 b
ELEVATIONS ARE TO BE KEPT A MINIMUM OF 2 FEET ABOVE ANY 3 m
INDICATION OF SEASONAL HIGH GROUNDWATER. RAISE THE REQUIRED Minimum Garage Floor Elevation - 98.2' rf b
ELEVATIONS IF ACTUAL EXCAVATIONS SHOW SEASONAL HIGH GROUNDWATER Minimum Basement Floor Elevation - 94.0' a
TO BE HIGHER THAN INDICATED ABOVE. Minimum Septic Bottom of Trench Elevation - 94.0' es
308.7-1-69 RC-000278-2017
Hodorowski Homes
58 Richmond Hills Drive
SFD w/Gas FP 2996 s.f., Gar. 423 s.f.
Map Reference:
Subdivision Modification '
Subdivision Plan
Thomas Schiavone
Dated: January 09, 2003 I
Last Revised: December 17, 2009
By: Nace Engineering P.C. and
Van Dusen & Steves Land Surveyors
I
I � ,
Lot 21 I
Lot 2
S 8101~00 E N _
-- 200.00,
_ -D
' o�51 S tB (pack J WV
�SPha/t Drt,e 1�
•r„y
W u A.C C1
m
o _ Lot 22 q
00 �o� 'a Area
�; 25,000± Sq. Feet �, 3C _
CO ' 0.57± Acres 71 9 1 O C
80. CIO
o •� — Court
N 3 Septic n I
to �23
�' _
U Tank N 1
a
m O �
JrJ V
Lot 20 Escape 14�e11 '
_ I IJ O
1 S'Setback
200.00 1 a
N 81 D 17100,,
Lot 3
w 1
I
Plof Mf jy Lot 23 s L5 l4D LG V 15 �1 �' �' iIt—�\�
C sr
I �
OCT 10 M4 -- FINAL SURVEY
cc r
rc, t TBVUDG SY
301 N &CODE
S�QLANDS�
DateN October 9, 2017
a D u S Map of a Survey made for
'UNAUTHORIZED ENSED L N OR ADDITION TO A SURVEY Scale 1'=30'
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
& NEW YnON S SECTION 7209,SUB-DIVISION 2,OF THE Christian R a e th
NEW YORK STATE EWCATION UW.'
S O11LY COPIES FROM THE Or-11F L I THIS SYOPI
MARIE MALL All CONS DE E THE LAND SURVEYORS
SEAL SHALL BE CONSIDERED TO BE VAL1D TRUE COPIES.' •F`./7
'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE And
E74STING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED
L a n. d S u r v e y o r s LAND SURVEYORSTHE NEW .SAID CERTIFICATIONS OF PROFESSIONAL
RUN ONNLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND Courtney Gagnon SHEET 1 OF 1
ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL
169 Havlland Road Queensbury, New York 12804 AGENCY AND LENDING INSTITUITION LSTED HEREON,AND
TO THE 0.SSIGNEES Of
THE LENDING INSTITUTI011'
Town of Queensbury, Warren County, New York
(518) 792-8474 New 11ork Lic. No. 50135 NO. DATE DESCRIPTION DWG. NO. 02080-lot 22
NACE ENGINEERING., P.C.
169 Haviland Road, Queensbury, NY 12804
Phone-518-745-4400 Fax -518-792-8511
October 11, 2017
Job #46170
New York State Dept. of Health
77 Mohican Street D [E C [E 0 V E
Glens Falls, NY 12801
OCT 12 2017
RE: Barringer Heights Subdivision - Queensbury(T)
58 Richmond Hill Drive (Lot#22) - Septic System TOWN OF QUEENSBURY
COMMUNITY DEVELOPMENT
Dear Sir/Ma'am: R.0 - Z •
This letter is to inform you that we inspected the completed septic system for the house on 58
Richmond Hill Drive (Lot#22) in the Barringer Heights Subdivision on July 18, 2017.
The septic system as installed was for a four bedroom house and consisted of a 1,250 gallon
septic tank and 200 lineal feet of absorption trench constructed with stone and perforated pipe.
The system conforms to the requirements of the approved subdivision design drawings.
Please call me if you have any questions or concerns.
Sincerely,
Thomas R. Center Jr. , PE
cc: Dave Hatin, Town of Queensbury
Patt Corradi, Hodorowski Homes
Map Reference:
Subdivision Modification '
Subdivision Plan
Thomas Schiavone
F '
Dated: January 09, 2003
Last Revised: December 17, 2009
By: Nace Engineering P.C. and s l
Van Dusen & Steves Land Surveyors '
s x
Lot 21 ' 1:
Lot 2
S 81017100. ,E
200.00' ' be m
U
WV n
D15TRIBUTION BOX �✓
.�
Y -- A.CQ
tR! m
p m
OO _ L 0 t 22 L (a ``-
1 00 'o Area o ti `"--
1 "j' 25,000± Sq. Feet co a o 3 -��
N o = N �., CrossQ 0.57± Acres N C
= r 80.0, O z o i t
f o
�QI.117.
1 =
1,250 GAL. ,� O '
SEPTIC TANK O
L 0 t 20 �� E�Pe Well Poo
15'Setback
200.00
N81-17,00
81 77'DO„ W
Lot 3
ABSORPTION
TRENCHES '
4 @ 49'EA. f AS BUILT
� Lot 23 �
Th.,
`d A
1.
C1
4'`�s:`. ._. :?: .� SEPTIC PLOT PLAN �4� 41w0f
i HAVE SEEN OR
ALL OBJECTS
SUCH OUSES, TREE , F OCT 12 2017 11 +
SHO ON THIS D E T.I H E PERSON LLY
SEPTIC ;SYSTEM - AS BUILT BY NACE ENGINEERING 1 ME UREDTHEDI SET FORT 0 THIS COMMUOF NITYDEVELOPMENT
BSBs RY--
UR
DA
Date, October 9, 2017
us Map of a Survey made for _
'UNAUTHORIZED ALTERATION OR ADDITION S A SURVEY SCaLe 1'-30'
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
& NEW YON S TE DN A OB.SUB-DIVISION z�,� Christian R a e th
NEW YORK STATE EDUCATION LAW."
S 'ONLY COPIMTn A FROM THE OF ME L N 5U SURVCY
MARKED WITn AN ORIGINAL Of THE IMID SURVLVOFS
SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPES." 1
`CERTIFICATIONS INDICATED HERON SIGNIFY THAT And 1
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE
EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED
LanOF PROFESSIONAL
d Survey ors LAND SURVEYORS.SAID CER STISFlOCAATWNS SHALL RUN ONLY
TO THE PERSON FOR WHOM THE NEW YORK STATE 1HE SURVEY IS PRO-AM.AND Courtney Gagnon 8FiEffr 1 OF 1
ON HIS BEHALF TO THE TITLE COWANY.GOVERNMENTAL
169 Haviland Road Queensbury, New York 12804
AGENCY�I� THE LENDI Gni�N"°�°"'A"°
Town of Queensbury, Warren County, New York D 10/11/17 SEPTIC SYSTEM AS—BUILT
(518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 02080-lot 22