Loading...
RC-000511-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000511-2016 Date Issued: Wednesday, June 21, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000511-2016 has been completed. Tax Map Number: 295.19-1-47 Location: 3 PINEWOOD AVE Owner: David Casey Applicant: Hilltop Construction This structure may be occupied as a:Residential Addition first floor 352 sq. ft. includes 3-season porch and laundry room and master bathroom. By Order of Town Board TOWN OF QUEENSBBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 1W Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000511-2016 Tax Map No: 295.19-1-47 Permission is hereby granted to: Hilltop Construction For property located at: 3 PINEWOOD AVE In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: David Casey Single Family-Addition $85,000.00 Owner Address: 3 Pinewood AVE Total Value $85,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Hilltop Construction 51 Crowley RD Hudson Falls,NY 12839 Plans&Specifications Residential Addition first floor 352 sq.ft. includes 3-season porch and laundry room and master bathroom. $100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,August 13,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the ex/pi tion JJJdatkdugust Dated at the Town of ueensb • f/ �hu18,2016 SIGNED BY: �/ for the Town of Queensbury. Director of Building&Code Enforcement r1U_NU1rAL J'IRUU I UME AYYL1UA'1'1U1N Office Use Onlv Date:- Permit No. l � �8_Cao Ifo Tax Map ID 9 Permit Fee ;cc 9 Zone Historic? _Yes No Rec Fee Subdivision Name G( Lot# Site Plan# Subdivision# Project Location Au.e . TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) 4\J; d ao-n %� C-,_ Case Address 3 PA LM , k e e h 56L,.r I rLc,�,•)o 0 Phone/Email 7q3 "371 '1 J I Case 3 E y 0610 C) . CO vr-*� Applicant T( `-�o Address 51 k o c-A H Ud son Fa 1(s 11 tin Phone/Email 0335' Cmd a hillfo Cortstrucf`onco . com Contractor r-a.n Address Phone/Email Contact Person for Building&Codes Compliance m re c hi S n. Phone as q- $r/0 y TYPE OF CONSTRUCTION ,/Check all that apply New Addition Alteration 11 floor sf 2nd floor sf Total sf Height Single Family s��a 55 A Two-Family 1J�7 Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (l, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition 3- ouon 0 _"ui,dKy Masfer Source of Heat(circle one) E X i 5'f i n Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys 110 h Are there structures not shown on plot plan? n a Are there easements on the property? n O Site Information: a. Dimensions or acreage of lot 3 Q C re S q 3 X 150 b. Is this a comer lot? _Yes _No c. Will the grade be changed as a result of construction _Yes ✓No d. Public water or Private well (circle one) Public Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed(labor or materials) $ 135, 000 DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 01Y)dv S• DATE: SIGNATURE: 0.'A" 'J QaLa–t" DATE: F- -off/G For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 1ZREScheck Software Version 4.6.2 Compliance Certificate Project Dave &Janice Casey Energy Code: 2010 New York Energy Conservation Location: Warren County, New York AUG Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 160 ft2 Glazing Area 3% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 3 pinewood ave. Queensbury, NY 12804 ,Compliance: Passes using UA trade-off Compliance: 20.0%Better Than Code Maximum UA: 45 Your UA: 36 The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont' U-Factor UA Assembly or R-Value R-Value Perimeter Ceiling 1: Raised or Energy Truss 160 38.0 0.0 0.025 4 Wall 1:Wood Frame, 16"D.C. 336 21.0 0.0 0.057 19 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.290 3 Crawl 1: Solid Concrete or Masonry 168 0.0 10.0 0.079 10 Wall height: 4.0' Depth below grade: 3.0' Insulation depth:4.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building:!ns been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck VerSID and t comply�ith the ry requirements listed in /9-Nathe RESChtgk^pection Checklis . p� /A l6ec)AM V—S r uta - A^ 49- Name-Title me-Title Sig ture SE - Y Date �nKEIT6' 295.19-1-47 RC-000511-2016 `\ z Casey, David & Janice 3 Pinewood Avenue F o Res. Add. (porch, laundry, bath) 352 s.f. Project Title: Dave &Janice Casey L Report date: 07/18/16 Data filename: Untitled.rck Page 1 of 6 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column Is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verifled Field Verifled # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &RC .ID 103.2 Construction drawings and ❑Complies [PR1]1 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building []Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code ❑Not Observable 40 compliance for lighting and ❑Not Applicable mechanical systems.Systems serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment Is Heating: Heating: ❑Complies [PR2]1 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads per ACCA Manual J or Cooling: j Cooling: ❑Not Observable other approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Dave &Janice Casey Report date: 07/18/16 Data filename: Untitled.rck Page 2 of 6 .section # Foundation Inspection Complies? Comments/Assumptions &Re .ID 303.2.1' Exposed foundation Insulation ❑Complies [Foil]' protection. ❑Does Not t✓' []Not Observable ❑Not Applicable 403.8 Snow melt controls. '❑Compiles [F012]2 ❑Does Not []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 Low Impactfiler 3) Project Title: Dave &Janice Casey Report date: 07/18/16 Data filename: Untitled.rck Page 3 of 6 Section Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.4.47 Fenestration that Is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 []Not Observable or has Inflltratlon rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16)2 sealed at housing/Interior finish []Does Not V, and labeled to indicate&It;=2.0 cfim leakage at 75 Pa. [_-]Not Observable ❑Not Applicable 403.2.2 All Joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes,and ❑Does Not u. building cavities used as return ❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not []Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R-_ R-_ ❑Complies [FR17]2 above 105 OF or chilled fluids ❑Does Not 9, below 55 of are Insulated to R-3. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water R-_ R-_ ❑Complies [FR18]2 pipes are Insulated to R-2. ❑Does Not []Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air []Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Dave &Janice Casey Report date: 07/18/16 Data filename: Untitled.rck Page 4 of 6 ,Section # Insulation Inspection Complies? Comments/Assumptions & Re .ID 303.1 ' All Installed Insulation labeled or ❑Complies [IN13]2 Installed R-values provided. ❑Does Not ❑Not Observable ❑Not Applicable . Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier3) Project Title: Dave &Janice Casey Reportdate: 07/18/16 Data filename: Untitled.rck Page 5 of 6 section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 402.4.2; Building envelope tightness ACH 50 =_ ACH 50=_ ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [F[17]1 of<7 ACH at 50 Pa.This requirement may Instead be met []Not Observable via visual Inspection, In which ❑Not Applicable case verification may need to occur during Insulation 'Inspection. 403.2.2 Duct tightness via post- _cfm _cfm I❑Complles [FI411 construction with maximum ❑Does Not $ leakage of 8 cfm to outdoors,or []Not Observable 12 cfm across systems.For rough-In tests,verification may ❑Not Applicable need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies [F1912 'Installed on forced air furnaces. ❑Does Not []Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat Installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not V, accessible manual controls. []Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not V []Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. j ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Iter 3) Project Title: Dave &Janice Casey Report date: 07/18/16 Data filename: Untitled.rck Page 6 of 6 �( 2010 New York j Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 10.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments 3/13/2017 6 : 13 PM FROM : 5183146044 TO: +15187454437 P. 1 SSLECTIOCAL NSBffCTJoras a DUPLIC-NE MUNICIPAL!RECORD Permit tia- . Occupa.+ N0.` Smus Gi. - CYn a Stag imuffatinasI ourcv=esideehasbeeavicvaitym =L'dp=m=toappUcablecedes_ in=Uedby -II TZko ( " lViSl}bt E�aPAF, tTVl�B.Tr PE�voll.AQENc,LRS ROUGH WIRING OUTLETS i HP_AR coiMONER SWUCHE5 JVMING&CONiRMFOR RECEPTACLES H.PiuMP MOAB KW.OVEN AM-?SERVi(.S EQUIPa Sr% HA GAMAGEDISPOSA-T O i AW—SIBERVICE CONDUCTORS KNL DISHWASHER KW.SURFACE UNfr KW.DRYER KV'±RANGE A9/P AECElriACtE KW-WAtE2 HEATER FRAC-HP.Vg1TFANS .�QTORS7-LR Ina Tm trta ua�w vc in{�a uc i z z s mlis a� a m m�si zc im MARKNUWER OF EACH SIZE APPARATUS yl5 TS � cc � u � n �u =� ' TOWN OF OUEENSBURY _ BUILDING & CODES - MAP REFERENCE MAP OF 5EGTION 2 OF WE5TLAND bYt LE5LiE W. GOULTER ' DATED, 5EPTEMBER 9. 1955 LOT 110 IPF LAND5 N/F OF Ri5T A5PHALT DRIVE \ A5PHALT DRIVE I �•° 1 STORY - ~\ 'HOOD FRA'jFD HOUSE IPF - DC / DEGK L OT 60 t-1 0,38 acres �+ _- !° ` j5LAND5 N/F OF ` �` PA500 C> lr2 ,'f rp , 0 1 HAVE PER'0i4,3 (_Y AJEASURED THE D ]TAIU�iC r }f FROM !�"iL= �r`Zt:�}�LU ]ti( � S.livF:`a TO THE LEI GENU a \ J (J / (` �IRS IRON ROD 5ET / TO BE 5ET a\ � .� IPFo = IRON PIPE FOUND slcniA-ruRr[) ��/ln ° a V - ___.._.-_-----,.__-- DAIE 10.> = UTILITY POLE LOT _ 112 '° -Q = WOODEN FENCE LINE o = METAL FENGE LINE o��/ LAND5 N/F OF / LAND5 N/F OF AUER13AGrf o LAROGK 295.19-1-47 RC-000511-2016 Casey, David & Janice 3 Pinewood Avenue Res. Add. (porch, laundry, bath) 352 s.f. UtNUIi{CFd2EA AI.tEFAn4tt OR AGGITi4il IO A`.rURrY .....,y•..._.. Da ce,AF'f2IL 25 2006 & MAP fim rion rC A U-IcTmi ED LAt O J:RVEYC,Ig ,F n A Map of a Survey made for � Scale t'�20' ',tclAncri OF:zcnc11 7263.S7.'0-w'.+aGtl x,OF n� h'cN YCfti{STATE EOVCZ i TAW.- • - ,,---y IXY'ES FRW THE CY G140L CF Thus SURVEY - - ►'�..-aJp - NAPYIA'Willi ul Ca't;GtNN_OF mE V7;0 5(jRWICAR - SEAL WI.L BE CCt190EFiE0 10 UE VAVQ CHUF Cwzv _ 'Cors1WRIl f WAS ItdXCATEB I.I A i a,t,IL t i}IATnit -_ - Larid ,�''"''q{ �g1 7 7 - us RIG WAS PREPAHEO Bt ACCGiQAjh(;E Yd ltt niE David P-y 7�.rJ R. �` y - WAL 13Y THE C V'OF 5TAII E FCti LViO-`,L(ASSWARON i1ERXi5 P:]iPTED _ [ ''�(t !'YO.Ji - V,./ = GHOISMUCRS SNOICEHn nLNS ALL RUH�Otd.Y = TO TIE PERSON FOR Y+NCU n'E SVRVEY N PREPAnO.AND - - - CN Fi^>UfkiNF TO TBE TITLE COSS?AF{Y,C{1VERNitiNTAE SHEET 1 OF 1 169 T-Iaviland Road. Queensbury, New York 12804 � ACFi;orAe+nEE.*�mrrGnlsnlvmc+laSlEuhFxEcrtAF4t `�'Oi?ltZi of Queensbury, Warren COI:IZity, New York TO RIE ASSTCNEES OE lNE EENUN6 INSIIN IICYi' - t (518) 792- 474 New York ftic. Na. 50135CASEY G1601 N0. DATE D `" RIP710N OW G. NO. 06074 295.19-1-47 / 81--G-19