SOLAR-000702-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000702-2016 Date Issued: Friday, October 28,2016 This is to certify that work requested to be done as shown by Permit Number SOLAR-000702-2016 has been completed. Tax Map Number: 309.9-3-34 Location: 68 CONNECTICUT AVE Owner: Wilfred Trembley Applicant: Solar City This structure may be occupied as a: Solar Panel System 195.25 s.f. No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY ow 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000702-2016 Tax Map No: 309.9.3-34 Permission is hereby granted to: Solar City For property located at: 68 CONNECTICUT AVE In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Wilfred Trombley Solar Panel-Residential $3,518.00 Owner Address: 68 CONNECTICUT AVE Total Value $3,518.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Solar City 110 Box 670 Amsterdam,NY 12010 Plans&Specifications SolarPanel System 195.25 s.f. No Ratter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 13,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Q ensbury 1 / "�ursd 2016 SIGNED BY: (IjYjr(/ �VJ for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only ACCESSORY STRUCTURE APPLICATION Received ❑� L�� DATE Tax Map ID TAx MAP ID 309.9 - 3 - 34 Permit No. zck,LPI, L- Ii Z- XI L, ZONING Permit Fee -` Rec Fee HISTORIC SITE _Yes _No Approvals SUBDIVISION NAME Lot# APPLICANT Loreen Harvey OWNER Wilfred Trombley ADDRESS P.O. Box 670 ADDRESS 68 Connecticut Avenue Amsterdam, NY 12010 Queensbury, NY 12804 PHONE 518 - 332 - 0671 PHONE 5187933901 CONTRACTOR Solar City COST OFCONSTRUCTION(ESTIMATED): 13,518.00 ADDRESS: P.O. Box 670 BUILDING ADDRESS: 68 Connecticut Avenue Amsterdam, NY 12010 Queensbury, NY 12804 PHONE: 518 - 332 - 0671 CONTACT PERSON FOR BUIL DING&CODES COMPLIANCE Loreen Harvey PHONE 518-332-0671 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 2""floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck Detached Garage(#of cars Dock Pole Sam 0f, 12 Alb Porch-open *"Porch—3 season,Covered, Enclosed Shed Other Accessory Structure(s) 195.25 Sq ft "Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: Loreen Harvey Date: 10 - 7 - 16 Signature: 1 ,, Date: 10 - 7 - 16 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 ACCESSORY STRUCTURE APPLICATION (Requirements, Notes, Changes) REQUIREMENTS: 1. Two (2)sets of the following documentation with the application and fee: a) Plot plan drawn to scale with the use of a survey map, if possible(40 scale =40 feet) b) Indicate proposed structure(s), showing setback dimensions from all surveyed property lines c) Show location of all existing structure(s)on the property d) Show location of water supply(well or water lines) e) Show location and configuration of septic disposal system or sewer line. 2. Structural drawings to include: Floor plan; Foundation plan, Cross Sections, Elevations 3. Registered Architect or Engineers stamp, signed&sealed for residential additions/alterations and any commercial construction costs over$20,000 NoTEs: 1. A permit must be obtained before beginning construction 2. This permit is for any structure other than residential principal structure (house) to include, but not limited to: garage, shed, dock, deck, carport, pole barn, greenhouse, etc. Refer to Informational Brochure No. 3 —Accessory Structures— Sheds/Fences. 3. Changes to Plan —Any changes prior to or during construction will require submittal of amended plans (review and re- approval are necessary) 4. Withdrawn Permits: 20% of the initial fee is retainable by the Town. No fee is refundable after 1 year from initial application date. 5. Additional review: All applications are subject to Zoning Administrator, Code Compliance and Structural Plan Review. CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL): Residential Building Code • New driveway requirements for structures located over 300 feet from main road • Spray foams are allowed to be exposed in rim joist box only, must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing oversteps • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles • GFI protection for all other receptacles in kitchens, bathrooms,garages and unfinished basements • All receptacles must be tamper resistant • Carbon Monoxide detectors must be located within 15 feet of sleeping areas; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Enerqv Code • Blower door tests required by credential contractor or structure inspection by air barrier supplier and certified compliant • Programmable thermostats required • Lighting must be 50% energy saving light bulbs • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit • ResCheck inspector's checklist must be available at time of insulation inspection 2 Town of Queensbury Building &Codes Accessory Structure Application July 2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. 04 Q C BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. eC' CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING c DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CD EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. `* (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING Co EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. ® � E > GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE > GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY >, HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. v I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL TOWN OF QUEENSBURY Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). BUILDING DEPARTMENT Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Based on our limited examination Com Fiance �? a 0- Mth our comments shall not be construed as 6? 0 kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR indicating the plans and spp2crfications are in a� o kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC full compliance with the Buildin Codas of LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). Ne►vYort Sta4e, g M l= coo 0 MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE TOWN OF 'QUcENSBURY OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE B�rL�` � & ��� PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING 9� ,� POI POINT OF INTERCONNECTION HARDWARE. Reviewed By. 1 1 � ��)Itl PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE p -- SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. Date: S STAINLESS STEEL l STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT SII .' PV1 COVER SHEET .', PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES rr 1 '� •� PV5 UPLIFT CALCULATIONS 1, - PV6 THREE LINE DIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2010 ;. Cutsheets Attached I R.C.N.Y.S. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH - THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Queensbury Town, Warren County _ REV BY DATE COMMENTS REV A NAME DATE COMMENTS I UTILITY: National Grid (Niagara Mohawk) CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-1281679 ®s® BENEFIT OF WILFRED TROMBLEY Wilfred Trombley RESIDENCE Jerron Lloyd ®®�;������' NOR SHALL IT BE"DISCLOSED SN WHOLE OROLARCITY CIN M�,"n"G SYSTEComp 68 CONNECTICUT AVE 2.86 KW PV ARRAY ° ly. PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 wFlashing—Insert ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: QUEENSBURY, NY 12804 THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo,CA 94402 INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARgTY INC. SOLAREDGE SE3000A—US—ZB—U COVER SHEET PV 1 9/28/2016 (888)—SOL—CITY(765-2489)www.Wercity.com PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH:272 ARRAY AZIMUTH:272 MATERIAL:Comp Shingle STORY. 2 Stories PITCH: 20 ARRAY PITCH:20 MP2 AZIMUTH:92 ARRAY AZIMUTH:92 MATERIAL:Comp Shingle STORY: 2 Stories a PITCH: 20 ARRAY PITCH:20 ami (E)DRIVEWAY MP5 AZIMUTH:272 ARRAY AZIMUTH:272 o MATERIAL:Comp Shingle STORY: 2 Stories U 0 ARRAY PITCH:20 00 MP6 AZIMUTH:92 ARRAY AZIMUTH:92 MATERIAL:Comp Shingle STORY: 2 Stories O ° % a h I F LEGEND I ° ZIA \ I 'FSB 0 (E) UTILITY METER & WARNING LABEL \ y�� :9 INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS \ / / © AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS Front Of House D DISTRIBUTION PANEL & LABELS LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER RAPID SHUTDOWN / 5/12 �m C STANDOFF LOCATIONS �� Z1�5 -- CONDUIT RUN ON EXTERIOR M� u CONDUIT RUN ON INTERIOR / M A U GATE/FENCE B HEAT PRODUCING VENTS ARE RED 3' FSBIF- �, 3' FSB Lam, INTERIOR EQUIPMENT IS DASHED SITE PLAN N Scale: 3/32" = 1' WE 01' 10' 21' S CONFIDENTIAL— THE INFORMATION HEREIN X06 NUMBER: JB-1 281679 00 PREMISE OWNER: DESCRIPTION: DESIGN: pak� o CONTAINED SHALL NOT BE USED FOR THE WILFRED TROMBLEY Wilfred Trombley RESIDENCE Jerron Lloyd a rC� y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 68 CONNECTICUT AVE 2.86 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION W TH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME SHEEL• REV: DATE Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 SOLAREDGE # SE3000A—US—ZB—U SITE PLAN PV 2 9/28/2016 (888)—SOL—CITY(765-2489)www.solarcity.com S1 S1 „ (E) LBW 11' SIDE VIEW OF i�P1 NTS (E) LBW . � E SIDE VIEW OF �1P2 NTS MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 23" STAGGERED MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 32" 14" LANDSCAPE 64" 23" STAGGERED RAFTER 2x6 @ 16"OC ROOF AZI 272 PITCH 20 STORIES: 2 PORTRAIT 32" 14" ARRAY AZI 272 PITCH 20 ROOF AZI 92 PITCH 20 C.J. 2x4 @16 OC Comp Shingle RAFTER 2X6 @ 16„OC STORIES: 2 ARRAY AZI 92 PITCH 20 C.J. 2X6 @16” OC Comp Shingle S1 S1 (E) 2x6 (E) 2x6 4" 4" 56- (E) LBW 6 !(E) LBW E SIDE VIEW OF MP5 NTS F SIDE VIEW OF MP6 NTS MPS X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP6 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 23" STAGGERED LANDSCAPE 64" 23" STAGGERED PORTRAIT 32" 14" PORTRAIT 32" 14" ROOF AZI 92 PITCH 20 RAFTER 2x6 @ 16"OC ROOF AZI 272 PITCH 20 STORIES: 2 RAFTER 2x6 @ 16"OC ARRAY AZI 92 PITCH 20 STORIES: 2 ARRAY AZI 272 PITCH 20 Comp Shingle Comp Shingle CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-12 816 7 9 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR'HIE WILFRED TROMBLEY Wilfred Tromble RESIDENCE Jerron Lloyd BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Y y NOR SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing—Insert 68 CONNECTICUT AVE 2.86 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ 3055 CleaMew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV. DATE T:(650)Son Maeo, CA 94402 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3000A—US—ZB—U STRUCTURAL VIEWS ) P V 3 9 28 2016 (888)—SOL—CITY(765-2489 www.solarcity.com PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. --------- --- -------- ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH ZEP FLASHING INSERT (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. 1 STANDOFF JB281679 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �®\ Q � CONTAINED SHALL NOT BE USED FOR THE WILFRED TROMBLEY Wilfred Trombley RESIDENCE Jerron Lloyd �,��", ° BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: a® i� I r0 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 68 CONNECTICUT AVE 2.86 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES QUEENSBURY NY 12804 THE SALE AND USE EOF PT ITHE RESPECTIVE N CONNECTION WITH 11 REC #ll REC260PEZ 3055 geaMew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ( ) tt PAGE NAME SHEET: REV: DATE San Moteo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE3000A—US—ZB—U STRUCTURAL VIEWS PV 4 9/28/2016 (888)—SOL—CIN(765-2489)www.solorclty.com UPLIFT CALCULATIONS La—k, -Lem a-ErucLurdi vu ays Design Software Mounting Plane Information Roofing Material Camp Roof Roof Slope 200 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters PV System Type SolarCity SleekMount— Zep System Type ZS Comp Standoff Attachment Hardware Comp Mount SRV Spanning Vents No Wind and Snow Desion Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Ultimate Wind Speed V-Ult 115 mph Fig. 1609A Exposure Category C Section 26.7 Ground Snow Load pg 50.0 psf ASCE Table 7-1 Surrounding Roof Snow 35.0 psf ASCE Eq:7.41 Roof Snow Over PV Modules 35.0 psf ASCE Eq:7.4-1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA qh=0.00256(Kz)(Kzt)(Kd)(V^2) Velocity Pressure qh 27.2 Equation 30.3-1 psf Wind Pressure Ext.Pressure Coefficient U GCp U -0.88 Fig.30.4-2A/B/C-5A/B Ext.Pressure Coefficient Down GC Down 0.45 Fig.30.4-2A/B/C-5A/B Design Wind Pressure P p=qh(GCp) Equation 30.4-1 Wind Pressure U u -23.8 psf Wind Pressure Down down 16.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 23" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -218 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand Ca ad DCR 39.8% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 32" 66" Max Allowable Cantilever Portrait 14" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 15 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -183 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand/Capacity DCR 33.5% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-1281679 00 \a�$' v WILFRED TROMBLEY Wilfred Tromble RESIDENCE Jerron Lloyd ®_ •;�������� BENEFIT OF ANYONE EXCEPT SOLARCI7Y INC., MOUNTING SYSTEM: Y ®•.,c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 68 CONNECTICUT AVE 2.86 KW PV ARRAY ►a� m PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: QU EEN SB U R Y, NY 12804 THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ 3055 Clearview Way EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET REV. DATE San Mateo,CA 94402 SOLARCITY EIY INC. INVERTER: T-(650)638-1028 R(650)638-1029 PERMISSION QU SMENT SOLAREDGE SE3000A—US—ZB—U UPLIFT CALCULATIONS PV 5 9/28/2016 (888)-SOL-CITY(765-2489)www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:QOC40MW225 Inv 1: DC Ungrounded INV 1 —(1 )SOLAREDGE# SE3000A—US—ZB—U LABEL: A —(11)REC # REC260PEZ AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:27534273 Inverter; 30u0W, 240V, 97.5%; w/Unifed Disco and ZB, AFCI PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER 200A/2P Disconnect 2 SOLAREDGE SE3000A—US—ZB—U (E) LOADS /_� z�ov L1 ® L2 ® N 1 20A/2P GND _—____—_--__________ EGCI ___ DC+ Dc+ - - P1,MP2,MP5,MP6 ----------------- _ m JA GEC DG DC 1X11 /I� I B I GND __ EGC--------------------------------------- EGC ———--————————————— J I I I N I I EGC/GEC —J z z --- GEC --� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP POI (1 )SQUARE DA QQ220 PV BACKFEED BREAKER A (1 )CUTLER—HAMMER #DG221URB /r, PV 01)SOLAREDGE jE P300-5NM4ZS ®� Breaker, A 2P, 2 Spaces, Plug—On Disconnect; 30A, 240Vac, Non—Fusible, NEMA 3R /� PowerBox aptimizer,300W, ZEP, in MC4,out MC4 —(1 )Cro/qd Roo _(1 )CUTLER— AMMER y DC03ONB 5 8 x 8, Copper GroundrNeutral Kit; 30A, General Duty(DG) —(1QUARE D 146220 PV BACKFEED BREAKER Breaker, A 2P, 2 Spaces, Bolt—On 1 )AWG#10, THWN-2, Black (2)AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O , (1 )AWG#10, THWN-2, Red O (1 )AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.07 ADC (1 )AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC ..,. ... (1 )Conduit Kit;. , , ,, , , ,, , ,,, ,,,, , ,,,,, , , , , ,,,, , ,,,,, , -,(1 )AWG(J8,.THWN72,,Green , , EGC/GEC.—(1 )Conduit,Kit;.3. EMT.. ......, CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-1 281679 00 PREMISE OVINER: DESCRIPTION: DESIGN: �\\ o CONTAINED SHALL NOT BE USED FOR THE WILFRED TROMBLEY Wilfred Trombley RESIDENCE Jerron Lloyd ®aoa;����� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 'wo NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 68 CONNECTICUT AVE 2.86 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ SHEET: REV: DATE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T:(650) 63B-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: SOLAREDGE # SE3000A—US—ZB—U THREE LINE DIAGRAM PV 6 9/28/2016 1 (888)-SOL-CITY(765-2489)www.solarclty.com IARNING:PHOTOVOLTAIC��POWER SOURCE Label • • "• • •. : WARNING Per Code: _• WARNING Code:r Code: Per NEC 690.31.G.3 ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS ••1 THE DC CONDUCTORS OF THIS 690.35(F) •""" `' Label L• •n: TO BE USED WHEN PHOTOVOLTAIC DC ■ LOAD SIDES N1AY BE ENERGIZED UNGROUNDED ANDINVERTERIS IN THE OPEN POSITION MAY BE ENERGIZED DISCONNECTPer Code: R• ' ■ NEC •.1 ,- Label . . Label Location: PHOTOVOLTAIC POINT OF • ■ INTERCONNECTION Per Code: PerCMAXIMUM POWER-_A WARNING: ELECTRIC SHOCK POINT CURRENT(Imp) NEC ••1 , 690.54 ••- HAZARD. DO NOT TOUCH MAXIMUM POWER-_V .•1 TERMINALS.TERMIINALS ON POINT VOLTAGE(Vmp) BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM V MAY BE ENERGIZED IN THE OPEN VOLTAGE(Voc)- POSITION. FOR SERVICE SHORT-CIRCUIT A DE-ENERGIZE BOTH SOURCE CURRENT(Isc)_ AND MAIN BREAKER. ;�� PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT _ MAXIMMI. M AC - Label • • OPERATING VOLTAGE V WARNING Code:Per NEC ELECTRIC SHOCK HAZARD •1 IF A GROUND FAULT IS INDICATED • NORMALLY GROUNDEDLabel L• • UNGROUNDDEDOAND ENERGIZED CAUTION • DUAL POWER SOURCE Per ••- SECOND SOURCE IS 690.64.B.4 PHOTOVOLTAIC SYSTEM Label WARNING . " . ELECTRICAL SHOCK HAZARD Code: Location: DO NOT TOUCH TERMINALSNEC 690.17(4) CAUTION ■ • TERMINALS ON BOTH LINE AND Per ••- LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC690.64.13.4 DC VOLTAGE IS _ ALWAYS PRESENT WHEN a SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label Location: WARNING '• Code:Per INVERTER OUTPUT Label • • CONNECTION 690.64.13.7 PHOTOVOLTAIC AC • DO NOT RELOCATE Disconnect DISCONNECT Per •••- THISODEVICERRENTConduit NEC ••1 ■ Distribution ■ DC Disconnect Interior • • Label • • MAXIMUM AC A ` •• Load OPERATING CURRENT Per Code: MAXIMUM AC OPERATING VOLTAGE VNEC 690.54 '• Point of • • • . .• :a • • • � 0 55 Clearview Way San Mateo,CA 94402 0 • �.` � 1 ;;.SolarCity ZepSolar Next-Level PV Mounting Technology ',SOlarCity ZepSolar Next-Level PV Mounting Technology Components Zep System for composition shingle roofs 1 , j `--._Up-roof � - Leveling Foot crouna zep Interlock (Vey s;dc show") Part No.850-1172 _– Leveling Foot - _ _ — — -- ETL listed to UL 467 s L� Zep Compatible PV Module r Roof Attachment - Array Skbt Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 QQoMpAT.9 Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules cpmp"V" Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards �y • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13.2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM • - ��• REE PEAK ENERGY ZLINK SERIES 65.55+0.1 -1.38 _ - __-39.02 ...__ .. • HIGH PERFORMANCE -- - • ICIENCY i SOLAR PANELS YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY REE PEA _ r 47.24 U�Y*FR U5 IMPORT DUTY FREE _. FE ENERG 0.47 w I TEMPERATURE RATINGS =; t � Nominal Operating Cell Temperature(NOCT) 45.7°C(t2°C) I Temperature Coefficient ofP,„P -040%/°C Temperature Coefficient ofVor -0.27%/°C Temperature Coefficient oflsc 0.024%/°C REC Peak Energy Z-Link Series sola- All measurements in inches panels are the perfect choice for building solar systems that combine long lasting Nominal Power-P�,,,(Wp) 260 Cel[Type:r 60 REC PEmulti-crystalline product quality with reliable power output. Watt Class Sorting-(Wp) +/-5 3 strings of 20 cells with bypass diodes REC combines high quality design and Nominal PowerV°Itage-VMPP(V) 30.7 Glass: 0125 in solarglass with anti-reflection surface treatment manufacturing standards to produce high- NominalPowercurrent-ISP(^) Sso Back Sheet: Double layerhighly resistantPofy ester performance solar panels with Open Circuit Voltage-Voc(V) 37.8 Frame- Anodized aluminum(black) Short Circuit Current-Isc(A) 9.01 Zep Groove compatible uncompromising quality. Panel Efficiency(916) 15.8 JuncttonBox: IP67rated 0.156 in(12 AWG)soIarcable,2 x 47.241n The electrical characteristics are within+/-10%ofthe indicated values off c,V°C andP at standard Test conditions(STC). OMPA Valuesatstandard test conditions STC(airmassAM1.5,irmillance1000W7m',celltemperature 77•F(25'C)I. Connectors: H4Amphen0l �QG TAt ow irradiance of 200W/m2(AM 1.5&cell temperature 77•F(25°C))atleast97%of the STCpanel efficiencywill be achieved. Origin: Madein Singapore ELECTRICAL DATA @ NOCT RECHOPEZ� MAXIMUM RATINGS FA w Nominal Power-P_(Wp) 197 Operational Temperature: -40..-+185°F(-40...+85°C) COMP Nominal PowerVoltage-VMPP(V) 29.0 Maximum System Voltage. 1000VUL MORE POWER COMPATIBLE WITH Nominal PowerCurrent-1.(A) 6.81 Design Load. 501bs/ft2(2400Pa)long side PER FP ZEP GROOVE FRAME Open CircuitVoltage-Voc(V) 35.7 301bs/ft2(1436 Pa)short side Short Circuit Current-I.(A) 7.24 I Max Series Fuse Ra ting: 15A Nominal operating cell temperature NOCT(800W/m°,AM1.5,windspeedIm/s,ambient temperature 68•F(20•C). Max Reverse Current 15A MECHANICALDATA T AFF 10 year product warranty. Dimensions: 65.55 x 39.02 x 1.57 in(1665 x 991 x 40 mm) c �L us 25 year linear power outputwarranty Area 17.75ft'(165m') US IMPORT EASY TO USTEB (max.degression in performance of 0.7%p.a.). OUTYFREE INSTALL Weight: 431bs(19.5 kg) UL 1703,Fire rating:Type 1,Class C Note! All given specifications are subject to change without notice at any time. REC is a leading global provider of solar energy solutions.With more than 15 years of experience,we offer sustainable,high performing REC products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better I� meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com solar a r=@@ Single Phase Invetters for North America solar =@@ SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US I SE380OA-US SE5000A-US SE6000A-US SE760OA-US SE10000A-US SE11400A-US OUTPUT 9980 @ 208V SolarEdge Single Phase nverters • Nominal AC Power Output 3000 38.. 5000 . 7600 10000@240V 11400 VA For North America Max:AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450„�n�240V. ,-.. 10950@2400 V AC Output Voltage Min.Nom:Max.1.1) , 183-208-229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ A Output Voltage Mi.N -Max. AC Output Voltage Min:Nom:Max.i'I V � � V � V SE760OA-US/SE1000OA-US/SE1140OA-US 211-240-264 Vac ......................................... ............... .............. ................ ...... AC Frequency Min:Nom.:Maxi9 59.3-60-605(with HI country setting 57-60-60.5) Hz ......... . - - - - -- - ---- - -- - - __-.. 24 @ 208V 48 @ 208V Max.Continuous Output Current 125 I.....•16•.-,,,I„21,@240V,.L.....25 3242 @ 240V 47.5 A GFDI Threshold 1 A - I Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT ..Jer6,`. Maximum DC Power(SrC) 4050 5100 6750 8100 10250 13500 15350 W ..---- •r'� Transformer.....Ungrounded........... .................................................... Yes rf as ty Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc ......................................... ......9.5.....I.. ... -- -16.5@208VI 8 23 34.5 Adc �a72an,;.,•°" Max.Input Currentt'I 33 @ 208V 13 15 5 240V 1 30.5 @ 240V Max:In ut ShortCircuit Current 45 Adc d Reverse-PolarityProtection _ _ _ _ Yes Ground-Fault Isolation Detect on 6001u Sensitivity MaximuminverterEfficiencY-._....._. 97.7 98.2..... ......98.3-.. ----.98.3 98 9" 98 % - 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency.'..'.......... .....975-.--. 98 97.5 97.5 97.5 % _ .... .... ....... .............. ..98•t-a)240V.. ...... 97.5 @ 240V 1 Nighttime Power Consumption <2.5 <4 W ` ADDITIONAL FEATURES } Supported.Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) - ............ ............................ .................... ............... -. __ _.. Revenue Grade Data,ANSI Cl:.1 OptionalM d I - Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedl4' STANDARD COMPLIANCE UL1998,CSA 22.2 Safety..............•.-•-••.-•••.•-••. ...................................... ..G.. UL1741,UL16998,rid.Connection.Stan..dards IEEE1547 .. ........... .... ................ ..............................•---..................P ' Emissions FCC art_15_c_la_ss B INSTALLATION SPECIFICATIONS _- _._.. t AC output conduit size/AWG range .. .........................3/4"minimum./.16-6. . .AWG. . 3/4"minimum/8-3 AWG .................................... ............... . . . ... . DC input conduit size/tt of strings3/4 / 3/4"minimum/1-2 strings/ "minimum/1-2 strings/16-6 AWG AWG F?Rg?............................. 14-6 AWG 30.5x12.5x7.2/775x315x184 Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ FIH YWxD).............................. .............................. ...............I..... 775 x 315 x 260 mm WeightwithSafetySwitch............. .•---•-•-•51.2/23.2-_--.--.-I-..--.-...-...-.-••-54.7/24.7 88.4/40.1 Ib/kg i A Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user The best choice for SolarEdge enabled systems replaceable) Noise <25 <50 dBA - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Min:Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60versionavailableisl) 'F/'C Superior efficiency(9890) Range_.._.__•„ Protection Rating...................... ....................................................NEMA 311 - Small,lightweight and easy to install on provided bracket For other regional settings please contact SolarEdge support. "i A higher current source may be used;the inverter will limit its input current to the values stated. - Built-in module-level monitoring "�Revenue grade inverter P/N:SE-A-USOOONNR2(for 760OW inverter.SE7600A-US002NNR2). Rapid shutdown kit P/N:SE3000-110-s1. - Internet connection through Ethernet or Wireless -40vershm P/N:SEnuA-Us000NNU4(for 760OWinvenersE7600A-US002NNU4). - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled Safety Switch for faster installation - Optional-revenue grade data,ANSI C12.1 0 sunsa�cRoHS USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us Date: Vol. ^SolarCity ZepSolar Next-Level PV Mounting Technology ,lSolarCity ZepSolar Next-Level PV Mounting Technology ZS COMP Components for composition shingle roofs Mounting Block Array Skirt Interlock Part No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 1 - Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Description PV mounting solution for composition shingle roofs FA �°v Works with all Zep Compatible.Modules Oo ,nfPnAuto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fre Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip UL LISTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 850-1460 Listed to UL 1565 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No.850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar'ssole warranty is contained in the written product warranty for This document does not create any express warranty by.Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspals.com. Document#8OD-1839-001 Rev D Date last exported:April 29,201611:22 AM Document#800-1 83 9-001 Rev D Date last exported:April 29,2016 11:22 AM sdar=oo S o I a r=@@SolarEdge Power Optimizer- Zep Compatible""" Module Add-On For North America P300-ZEP SolarEdge Power Optimizer — IP300-ZEP(for 60-cell PV modules) INPUT Zep Compatible""' Module Add-On RatedlnputDCpowerl'I 300 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 Vdc For North America P300-ZEP MPPT...m* ng Range 810 Vdc Maximum Short Circuit Current(Isc) 10 Adc ............. ......................................................... .................... Maximum DC Input Cur ............................................ .................... Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % 0veryoft a a Cate go r y II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Adc Maximum Output Current 15 ......................................................................... .................... Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) 1� _ Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC. FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ..... ..................................................................... .................... SafetyIEC62109-1(class II safety),UL1741 ........................................................................... .................... ►f RoHS Yes INSTALLATION SPECIFICATIONS we, o Maximum Allowed System Voltage 1000 Vdc Dimensions including mounting bracket (W x L x H) 141 x 256 x 40.5/5.55 x 10.08 x 1.59 mm/in ................ ......... . w5 a Dimensions excluding mounting bracket (W x L x H) 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in ......................................... . . . .. ....... ......... .. .............. . .. • Weight(including cables and mounting bracket) 1170/2.54 kg/Ib o ............................................................... .................... Input Connector MC4/Amphenol/Tyco ........................................................................... .................... Output Connector Double Insulated;Amphenol ........................................................................... .................... Output Wire Length.................................................. .................... 0.95/3.0 m/ft Operating Temperature Range -40-+85/-40-+185 'C/'F Protection RatingIP65/NEMA4 ..................... .................................................... .................... Relative Humidity0-100 % I'I Rated ST[power of the module.Module of up to+5%power tolerance allowed.. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE THREE PHASE THREE PHASE 208V 480V Minimum String Length(Power Optimizers) 8 10 18 ........................................................................... .................... Compatible with Zep Groove framed modulesMaxim�m. .5t..ring. .Length(PowerO.ptimize. . . . .r5........................ ........... ) 2s. ...... 25 50 . ... . .. . ... ... ........ . ........ . . . Maximum Power per String 5250 6000 12750 W ....................................................................... .................... — Certified Zep Compatible""^bracket — Mitigates all types of module mismatch losses,from Parallel Strings of Different Lengths or Orientations Yes —.Attaches to module frame without screws-reduces on-roof manufacturingtolerance to partial shading ........................................................................... .... labor and mounting costs — Flexible system design for maximum space utilization - Power optimizer equipment grounded through the bracket — Next generation maintenance with module-level monitoring — Up to 25%more energy — Module-level voltage shutdown for installer and firefighter — Superior efficiency(99.5%) safety USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL AUSTRALIA www.solaredge.us li 10 SolarEdge TeChoOlogICS,Inc.All rights reser,ed.SOLAREDGE.til-SolarEdge logo.OPTIMIZED BY .