Loading...
RC-000351-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 -- Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000351-2017 Date Issued: Friday, December 29, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000351-2017 has been completed. Tax Map Number: 316.10-1-51 Location: 2 COBY RD Owner: Michael Jarvis, Christine Jarvis Applicant: CERRONE BUILDERS, INC. This structure may be occupied as a: SFD w/gas FP 2167 s.£ Garage 806 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000351-2017 Tax Map No: 316.10-1-51 Permission is hereby granted to: CERRONE BUILDERS,INC. For property located at: 2 COBY RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Michael Jarvis Single Family-New $360,000.00 Owner Address: PO Box 2316 Total Value $360,000.00 Glens Falls,NY 12801 Contractor or Builder's Name/Address Electrical Inspection Agency CERRONE BUILDERS,INC. 1589 State Route 9 Fort Edward,NY 12828 Plans&Specifications SFD w/gas FP 2167 s.f. Garage 806 s.f. $1,454.30 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,July 7,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the exptionAdate.)Dated at the Town of e �]rida J ,2017SIGNED BY: ����� ��'QQQ for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only Permit#: f—C• 515 • Z�1�" PRINCIPLE STRUCTURE PERMIT r APPLICATION Permit Fee:$ 46M-2-�O roan o oumnsbun *Rec Fee: $ S 5t7 742 Bay Road,Queensbury,NY 12804 q P:518-761-8256 www.aueensburV.net Invoice#: IF� Project Location: /1/M �Q9i)» KLL, k 664t Tax Map ID #: � b • Subdivision Name: *TOWN BD. RESOLUTION 86-2013: $850 recreation fee for new dwelling units: single family,duplexes/two-family, multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile homes. This Is In addition to the permit fee(s). CONTACT INFORMATION: il)l [ C ; • Applicant: �j ! 26M ? i Lud Name(s): Mailing Address C/S/Z• d Cell Phone: O Land Line: Email: Primary Owner (s): T Name(s): �,�0 � P. 7RA/%r Mailing Address, C/S/Z: Cell Phone:. Land Line: �) Email: • Contractor(sl: // rr ' Business Name: ale"Mcdi1,II Contact Name(s): Mailing Address, C/S/Z Anc ,lis lA dr✓ Cell Phone: Land Line: � ) Email: • Architect(s)/Engineer(s): Business Name: ` <fi FaG i/leis Contact Name(s): Mailing Address, C/S/Z: 20,4' aelv Cell Phone:J ) Land Line: ) Z6 Email: Contact Person for Building & Code Compliance: <-. Cell Phone: li ADO — Land Line: Email: Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 PROJECT INFORMATION: /r�esiclerilialTYPE: Commercial WORK CLASS: Single-Family —Two-Family Multi-Family(#of ) _Townhouse _Business Office _Retail —Hotel/Motel _Ind ustrial/Warehouse __Garage(#of cars _) Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUfARE FOOTAGE: 11T floor: k177 IST floor: OL'� 2nd floor: 2"d floor: 3`d floor: Total square feet: cf(244 4'h floor: Total square feet: 2167 ADDITIONAL PROJECT INFORMATION: / 1. Estimated Cost of Construction: $ 2. Proposed use of the building: 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): Gas Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances& Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO Explain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: /Fl a. What is the dimensions or creage of the parcel? 49 � yU t b. Is this a corner lot? YE NO c. Will the grade be changed as a result of the construction? YES N d. What is the water source? UBLI PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? .a-Id.rg3 Cc .:-: n., Pnnnplegr,..:;.. _ .ppi.r:: Revised Fc:T .: . DECLARATION: I. I acknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed 1, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: L i- Q� SIGNATURE: lot DATE: G l0 X7 Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.oueensburv.nec Permit#: Tax Map ID M Permit Fee: $ ; Invoice#: Project Location: Septic Variance? Yes No Primary Owner(s) Mailing Address Phone& Email Installer/Builder Mailing Address N. Phone & Email Engineer '� N Mailing Address s Phone& Email L. Contact Person for Building&Code Compliance: Phone: RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder YesNo 1980 or older Installed? (circle one) Spa or Hot Tub Yes No 1981- Installed? (circle one) 1992-Present v PARCEL INFORMATION: Topography Flat Rolling _Steep Slope _%Slope Soil Nature -Sand _Loam _Clay _Other Groundwater At what depth? )VIA Bedrock/Impervious materialAt what depth? AIM Domestic Water Supply —Municipal _Well(if well,water supply from any septic system absorption is—ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size 00 gallons(min.size 1,000 gallons,add 250 gallons for each garbage cylinder or spa/hot tub System bsorption field with#2 stone Total length ft.; Each Trench ft. Seepage Pit with#3 stone How many: :Size: Alternative System Bed or other type: Holding Tank System Total required capacity? :tank size ;#of tanks NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: d ,/JI DATE: La SIGNATURE: DATE: 6 Zd l Revised Febru 201/ Town of Queensbury Building&Code Enforcement ry FUEL BURNING APPLIANCE & Office UseOnly QL CHIMNEY APPLICATION Permit#: Permit Fee:$ lincn o((Luirnsbun' 742 Bay Road,Queensbury, NY 12804 Invoice:#: P:518-761-8256 www.gueensbury.net Project Location: l/ Tax Map ID N: Room of Install: /_.L{— �i1, Planned Install Date: Xy,C 601.7 **ONE APPLICATION PER APPLIANCE** �J CONTACT INFORMATION: • Applicant: Name(s): ly1 U/ Mailing Address C/S/Z• �('k4 L L Cell Phone: ( ,rlk') 36 7i Land Line: Email: • Primary Owner s Name(s): Mailing Address, C/S/Z: V Cell Phone:_( (�) Land Line: _( ) Email: • Installer Builder: �y BusinessName: Contact Name(s): �A1I Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) 4 U Email: Contact Person for Buildin & Code Compliance: Cell Phone: _( _) _ 7/f"- K�U Land Line: _( ) Email: Fuel Burning Appliance&Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _Fireplace Insert /Fireplace _ Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) _ Fireplace,factory built** �j/J **Manufacturer's name: ///�/�'�(T✓G Model #: //l �la SOURCE OF HEAT: Wood Coal Pellet /Gas CHIMNEY INFORMATION: Masonry: block brick stone _Flue: it —tie _steel 9–L size, in inches _Material*: double-wall _triple-wall insulated (*Manufacturer's name: Tf/Ci Model #: //l ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturers installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: o PRINT NAME: iQ C41dfelL� / SIGNATURE: 4 DATE: Fuel Burning Appliance&Chimney Application Revised March 2017 Dec, 21. 2017 8 ; 20AM VDIA No. 1636 P. 8 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. Cext a that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Cerrone Builders Date: 12/13/2017 Occupant: Same Location Coby Drive OccupancySingle Family Owg. Queensbury,Warren Co. NY Applicant, � Cerrone Builders Gianni Cerrone " 1589 Rt 9 L Fort Edward, NY 12828 . J Joseph A.Holmes No. - - - - - - 1.453141369376EL_ _ - - - - - - - - - - - Equipment 200-Amp, Service Equipment; 4/0 - Receptacles; 71 - Fixtures; 1 - 30 Amp Hard Wired Air Conditioner; 1 - Burneri.Wiring & Controls(Gas); 1 -20 Amp Hard Wired Dishwasher; 1 - 30 Amp Dryer Receptacle; 2-Vent Fans; 6-.Smoke Detectors; 11 -Arc Fault Breakers; 1 -240 Volt Welder This certificate applies to the electrical wiring to the electrical equipment listed immediately nun and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. upon a change in the use,occupancy or Ownership inspection. No warrant'is expressed or implied as to the mechanical safety.effi- of the property indicated above,this certificets shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revatldated upon reinspection by Middle Department system to whim this certificate applies be altered in any way,including but not limit- Inspection Agency, Inc, An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc.to initiate the inspection and revalidation any of the cOrrtponents Installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. DXyl7JAN 0 5 2018 TOWN OF QUEENSBURY BUILDING&CODES 9 Load Short Form Job: Jarvis Itesidenee,taueen... wri htsoft bate: May+,zfor Entire douse By: AnthonyAverss WeBRoPS LLC. F-C, —�`5l' �� Plan: Jarvis Residence 1880 82nd Avenue Suite 9 203,Vero Beach,FL 32966 Phone:800 810,3280 Fax 888 971-2999 Email:manualj@mbrepshwc.com Web:v.w, webrepsxholesalexom License: ... Project . • - j -----Fac:_-._.._. Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 j 11 �1iuN i 2 i Phone: 518 796-4654 Fax: 518 798-3069 1 Email: patten84@gmail.com Design • Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db (°F) 70 75 Construction quality Semi-tight Design TD (°F) 74 10 Fireplaces 1 (Semi-tight) Daily range - M Inside humidity (°h) 30 50 Moisture difference (gr/Ib) 29 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GMSS920804CN Cond GSX130301B AHRI ref 7367474 Coil CAPT3743A4A AHRI ref 5611306 Efficiency 92.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input 80000 Btuh Sensible cooling 19740 Btuh Heating output 74000 Btuh Latent cooling 8460 Btuh Temperature rise 72 OF Total cooling 28200 Btuh Actual air flow 940 cfm Actual air flow 940 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load CIg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Bath 34 1189 627 28 35 Mud Room 83 681 114 16 6 Stairs 72 1683 185 40 10 Clst 28 175 8 4 0 Kitchen 248 2637 2855 62 157 Eating Rm 86 3116 2000 74 110 Great Room 441 9833 3044 232 168 Entry 66 1713 615 40 34 Closet 22 68 27 2 1 Den 147 2717 1384 64 76 Cit 15 47 19 1 1 Hall 51 162 64 4 4 Bdrm 2 159 3217 1655 76 91 C12 19 256 39 6 2 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2017-May-01 09:09:11 wrightSOft Right-Sui e®Universal 2017 17.0.21 RS000902 Page 1 SCK ...lelopment,Jarvis Residence,Queensbury,NY.mp Cab=6U8 Front Door faces: S Bath 2 59 980 348 23 19 Lin 7 23 9 1 1 1Astr Btl1 95 1587 713 37 39 WIC 54 169 67 4 4 Mstr Bdrm 291 4886 1647 115 91 Rec Room 190 4671 1628 110 90 Entire House 2167 39811 17049 940 940 Other equip loads 13155 2657 Equip. @ 1.00 RSM 19706 Latent cooling 6619 TOTALS 2167 52965 26325 940 940 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightSOft RighlS09P ude®universal 2017 17.0.21 RS000902 zon-May-01 0age Page 2 ACCP. ---u>:lopmeni,Jarvis Residence,DueensbuM NY.rup Calc=MJB Front Door faces: 5 �011lpOil�l1 �sotlffi�rtJCtfOrlt Job: Jinrisnosldence,tlueeh... wrightsoft onto: May 1,9107 Entire louse By: Anthony Aversai WeBRePS LLC. Plan: Jarvis Residence 1860 82nd Avenue Suite Al 203,Vero Beach,FL 32966 Phone:800 810-3280 Fax:886 971-2999 Email:manualj@webmpshvac.com Web:w+ "Ihrepswh°lesale.corn License:... Project • • _ For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 29.4 26.5 Dry bulb (°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-tight) Construction descriptions Cr Area u"value Insul R Hill HTM Loss Clg HTM Gain rt" enrrw-°F m-°Rahn awrR+ auh Berea ebn Walls 12F-Osw:Frm wall,wd ext,r-21 cav ins,1/2"gypsum board int fish, n 625. 0.065 21.0 4.78 2988 0.61 382 2"x6"wood frm, 16"o.c.stud a 756 0.065 21.0 4.78 3611 0.61 462 s 368 0.065 21.0 4.78 1760 0.61 225 w 716 0.065 21.0 4.78 3421 0.61 438 all 2466 0.065 21.0 4.78 11780 0.61 1507 Partltlons 12F-Osw:Frm wall,3/8"wood shth,r-21 cav ins,1/2"gypsum board int 268 0.065 21.0 4.78 1279 0.13 35 fnsh,2"x6"wood frm,16"o.c.stud Windows 2 glazing,Or low-e outr,air gas,vnl firm mat,ck innr, 1/4"gap, 1/4"thk: n 106 0.320 0 23.5 2489 10.8 1143 2 glazing,Or low-e outr,air gas,vnl firm mat,ck innr,1/4"gap, 1/4"thk; a 16 0.320 0 23.5 376 40.6 650 6.67 it head hl s 112 0.320 0 23.5 2642 21.1 2372 w 17 0.320 0 23.5 409 40.6 707 all 252 0.320 0 23.5 5917 19.4 4873 Doors 11 DO:Door,wd sc type s 21 0.390 0 28.7 602 8.03 169 Ceilings 16B-38ad:Attic calling,asphalt shingles roof mat,r-38 cell ins,1/2" 2085 0.026 38.0 1.91 3984 1.15 2390 gypsum board int fish Floors 19C-19cscp:Fir floor,firm fir,6"thkns,carpet fir finish,r-2 ext ins,r-19 1947 0.049 30.0 1.25 2431 0.17 331 cav ins,tight crwl ovr,r-11 wall insul 64 0.049 30.0 1.25 80 0-17 11 all 2011 0.049 30.0 1.25 2511 0.17 342 21A-32t:Bg floor,heavy damp sol,6 depth,carp 80%fir fish 29 0.020 0 1.47 43 0 0 45 0.020 0 1.47 66 0 0 all 74 0.020 0 1-47 109 0 0 2017-May-01 09:09:11 wrightsoft Right-Buites universal 2017 17.0.21 RSUD0902 Page 1 ACCA ...velopment,Jarvis Residence,Queensbury,NY.rup Cale=W8 Front Door faces: S 1g �P®"��� �uf�f�lSr Job: Jarvis Residence,Queen... wri htsoft ®ate: May t,2107 s Entire House By: Anthony Averse WeBRepS LLC, Pian: Jarvis Residence 1880 82nd Avenue Sufte#203,Vero Beach,FL 32966 Phone:800 810-3280 Fax 888 971-2999 Email manualj@webrepshvac coin Web:w .webrepswholesale.com License: _. Proiect Information For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Notes: Jarvis Residence Design . • Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 74 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 39811 Btuh Structure 17049 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(88 cfm) 6990 Btuh Central vent (88 cfm) 951 Btuh Outside air Outside air Humidification 6165 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 52965 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19706 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 1 (Semi-tight) Structure 5060 Btuh Ducts 0 Btuh Central vent (88 cfm) 1559 Btuh Heating Cooling Outside air Area (ft' 2167 2167 Equipment latent load 6619 Btuh Volume (ft ) 23808 23808 Air changes/hour 0.43 0.15 Equipment total load 26325 Btuh Equiv.AVF(cfm) 171 60 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GMSS920804CN Cond GSX130301 B AHRI ref 7367474 Coil CAPT3743A4A AHRI ref 5611306 Efficiency 92.1 AFUE Efficiency 11.0 EER, 13 SEER HeatingInput 80000 Btuh Sensible cooling 19740 Btuh Heating output 74000 Btuh Latent cooling 8460 Btuh Temperature rise 72 OF Total cooling 28200 Btuh Actual air flow 940 cfm Actual air flow 940 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2017-May-01 09:09:11 g Right-Suite®Uniwmal201717.0.21 RSU00902 page 1 ACCA.-.velopmeru,Jarvis Residence,Queensbury,NY.rup Calc=MIe Front Door faces: S Manual S Compliance Report Job: Jarvis Residence,Queen... ` WrlghtSOft [late: May 1,2107 • Entire House By: Anthony Avera We13R@PS LLC, Plan: Jarvis Residence 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800 810-3280 Fax.888 971-2999 Email:manualj@mbrepshvac.com V*b:evnv.webrepsMolesale.com License:... Project • • For: Chris J Patten, Patten Property Development 7 Jackson Road, South Glens Falls, NY 12803 Phone: 518 796-4654 Fax: 518 798-3069 Email: patten84@gmail.com Cooling Design Conditions Outdoor design DB: 85.0°F Sensible gain: 19706 Btuh Entering coil DB: 77.7°F Outdoor design WB: 70.8°F Latent gain: 6619 Btuh Entering coil WB: 63.9°F Indoor design DB: 75.0°F Total gain: 26325 Btuh Indoor RH: 50% Estimated airflow: 940 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: Split AC Manufacturer: Goodman Mfg. Model: GSX130301 B+CAPT3743A4A Actual airflow: 940 cfm Sensible capacity: 19740 Btuh 100% of load Latent capacity: 8460 Btuh 128% of load Total capacity: 28200 Btuh 107% of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 52965 Btuh Entering coil DB: 63.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Gas furnace Manufacturer: Goodman Mfg. Model: GMSS920804CN Actual airflow: 940 cfm Output capacity: 74000 Btuh 140% of load Temp. rise: 50 °F Meets are all requirements ofACCA Manual S. wri htsOft 2017-?&y.01 09:09:11 9 Right-Suile®Universal 201717.0.21 RS000902 Page 1 .TCCA ...eelupment,Jarvis Residence,Queensbury,NY.rup Calc=MIB Front Door faces: S �t-r•t��zt:ttti B2B oo HVAC ORDER SUMMARY t^ehRepsWhdesale com Billing Information: Shipping Information: Invoice PDF#: 14007 Chris J Patten Chris J Patten Date: May 1,2017 Patten Property Development Patten Property Development Sales Rep 7 Jackson Road 7 Jackson Road South Glens Falls,NY 12803 South Glens Falls,NY 12803 Processed By: United States United States Tel:518 796-4654 Tel:518 796-4654 Email Address:patten84@gmail.com Purchase Order:Jarvis Residence 1 Manual J S D Manual J,S, Calculations 1 168.00 168.00 Sub Total: 168.00 Tax: 0.00 Shipping&Handling Free Shipping): _ 0.00 Grand Total: $160.001 Balance: 0.00 Payment Method:Credit Card Card Type:MC Card Number:XXXXXXXX9352 Expiration Date:02/21 WebREPS, LLC --- - - - - ,f0—� Toll Free: 800-810-3280 10! �'[�'� t.� jJ j, / ` Fax: 888-971-2999 VY{�[J.[�.1 PIS `-ales:,CT1,Ven€iePSHVAC.corn '880 82nd .A%;erue, Shiite 203. Vero Beach, FL 329056 facebook. Goode 'acebocr:;.com/EYP )rrp:Wolesa p,B2tc googifl.cora'+WebRerpsWholesaieB2B REScheck Software Version 4.6.4 fZCompliance Certificate N 0 Project Jarvis Residence LOr 00a) M M CD I Energy Code: 2015 1ECC i — `' J 1— M Location: Glens Falls o New York �I Construction Type: Single-family v�L��~� I i C : 1 Project Type: New Construction 7 i 27 Conditioned Floor Area: 2,167 ft2 y.. Glazing Area 17% I Vlh I I (-)c: . Climate Zone: 6 (7635 HDD) L N Permit Date: Permit Number: LY LCL Construction Site: Owner/Agent: Designer/Contractor: N D O Queensbury, NY 12804 VISION Engineering, LLC r U LL 206 Glen Street M —� N (n Suite 56 Glens Falls, NY 12801 Compliance: Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 348 Your UA: 348 The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or 1.1-Factor ILIA Ceiling 1: Raised or Energy Truss 2,072 38.0 0.0 0.025 52 Wall 1: Wood Frame, 16" D.C. 2,142 21.0 0.0 0.057 101 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 296 0.290 86 Door 1: Solid 18 0.200 4 Door 2: Solid 20 0.140 3 Door 3: Glass 34 0.240 8 Basement Wall 1: Solid Concrete or Masonry 1,710 0.0 15.0 0.048 81 Wall height: 7.8' Depth below grade: 6.3' Insulation depth: 7.8' Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Window 3: Vinyl/Fiberglass Frame:Double Pane 9 0.400 4 Floor 1: All-Wood joist(rruss:Over Unconditioned Space 48 30.0 0.0 0.033 2 Floor 2: All-Wood joist(rruss:Over Outside Air 46 30.0 0.0 0.033 2 Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 1 of 10 ' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Daniel W.Ryan P.E. Daniel W. Ryan P.E. 2017.06.2012:14:28-04'00' 6/20/17 Name-Title Signature Date OF co? OPN\E Q� _ I t . � w m 4'0. 07906 X20 9�FESs;ot P4 ' Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 2 of10 REScheck Software Version 4.6.4 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate El Does Not [PR111 energy code compliance for the 0 building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Q0 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: "Comp'!as 403.7 sized per ACCA Manual S based Btu/hr— Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods []Not Observable Btu/hr Btu/hr ❑Not Applicable approved by the code official. PP Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 3 of10 Section Plans Verified laid Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &Re .ID 402.1.1 Conditioned basement wall R-_ R-_ ❑Complies see the Envelope Assemblies [FO411 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall - '',❑Complies IFO511 insulation installed per ❑Does Not g manufacturer's instructions. []Not Observable []Not Applicable 402.2.9 Conditioned basement wall _ft ft ❑Complies See the Envelope Assemblies IFO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. []Not Observable ❑Not Applicable 303.2.1 A protective covering is installed - ❑Complies [PO1112 to protect exposed exterior - []Does Not v insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system iOComplies [FO12]2 controls installed. ❑Does Not u ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 4 of 10 Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 []Does Not table for values. [FR111 []Not Observable 8' ❑Not Applicable 402.1.1, .Glazing U-factor(area-weighted U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.1, average). El Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not IV with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not 0 instructions. []Not Observable I ❑Not Applicable ---------------------- 402.4.3 Fenestration that is not site built ❑Complies [FR2011 is listed and labeled as meeting El Does Not GO AAMA/WDMA/CSA 101A.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR1612 sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 .Supply and return ducts in attics ❑Complies '.. [FR12]1 insulated>= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where <3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated>= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not N' ❑Not Observable -[]Not Applicable 403.4 HVAC piping conveying fluids R-_ R-_ ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to aR- - [:]Not Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ,Qi ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R-_ R-_ []Complies [FR18]2 2:11-3. []Does Not J []Not Observable []Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]1 installed on all outdoor air ❑Does Not intakes and exhausts. []Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 5 of10 Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 6 of 10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable []Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table For values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable 0 ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and []Does Not [IN211 in substantial contact with the underside of the subfloor, or floor []Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least%of the ❑ Wood ❑ Wood ❑Does Not table For values. 402.2.6 wall insulation on the wall [IN311 exterior,the exterior insulation ❑ Mass ❑ Mass []Not Observable ,$ requirement applies(FR10). ❑ Steel ❑ Steel []Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable j❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 7 of10 Section Plans Vered Field Vered _ # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Reg. 402.1.1, Ceiling insulation R-value. R-_ R-_ ❑Complies see the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402'2'2' ❑ Steel ❑ 402.2.6 Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every 300 ft'. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies IFI2212 insulation include baffle adjacent ❑Does Not to soffit and eave vents that []Not Observable extends over insulation. ❑Not Applicable 402.2.4 Attic access hatch and door R-_ R-_ ❑Complies [FI311 insulation 2:11-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ❑Complies [FI1711 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/loo ❑Complies [FI411 cfm/100 ft2 across the system or ft' - ft2 ❑Does Not <=3 dm/100 ft2 without air []Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/loo cfm/loo ❑Complies [FI2711 determine air leakage with ftz ft' ❑Does Not either: Rough-in test:Total leakage measured with a []Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F12411 by manufacturer at<=2%of El Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary El Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable j 403.5.1 Circulating service hot water ❑Complies [Fill]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 8 of10 j Section Plans Verified Field Verified Complies? Comments/Assumptions & Re .ID 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed []Does Not HVAC equipment meet efficacy []Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating El Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F12812 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F12911 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated -water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side ❑Not Observable pressure loss of drain water heat recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (F1611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not V ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 9 of10 ( Section Plans Vered Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions I& Re .ID 401.3 Compliance certificate posted. ❑Complies [F17]2 ❑Does Not ❑Not Observable []Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI1813 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Jarvis Residence Report date: 04/24/17 Data filename: C:\Users\lrobision\Desktop\1152 rescheck.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.29 Door 0.24 Heating & Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments ...W. , ...... ......... .. ..........,.w ., �IPF DEED REFERENCE; ROBERT E. MCDONALD TO r MICHAEL R. JAR VIS �- DATED MARCH 10, 2017 _ IN BOOK 5524 PAGE 50 Co) IPF MAP REFERENCES; IVE I SPF COBY MAP OF A SURVEY MADE FOR © IPF CIFtF TOWN OF QUEENSBURY I o IPF DATED5, 1996 BY VAN DUSEN & STEVES N 86-17'05" E" p IPF 001 MAP SHOWING LANDS CONVEYED BY _ w MARY A. HOPKINS, WIDOW OF REUBEN W. HOPKINS TO OWEN BALL AND MABEL V. BALL I o w F DATED AUGUST 11, 1941 BY COULTER & ASHLEY I I , PROPOSED I HOUSE LANDS OF C;0.01 C\, _ MARGARET MCDONALD, w cv 00 00 o 00 I cv 0) co ev ; 0 U0 LO = 4 O 316. 10-1-51 LEGEND; 32535.3 Sq. _Feet 0. 74 Acres IPF = IRON PIPE FOUND IRF = IRON ROD FOUND = s CIRF = CAPPED IRON ROD FOUND I CIRS = CAPPED IRRON ROD SET 4 IPF IPF 1-1 IPF �.4 o,= UTILITY POLE 160' Cn_ 5 III "ai A I ' r IPF S 87 01 08 W � ... . ...d � _, .v .,... N 00 Lo CD Tov"It'l OF CA Cn LANDS OF PEf'.tMff PLOT j SANDRA JARVIS F{AVEPER'30O IAL `�{v1EASUREij CEJ TRANCE { 1 T4-lc FRC�P� I {E.PP )PERTY LIQ{ r cts N PR " ED Y/`�CzUCTUP.E(S)OR�SI�J (�` r tY a � I DATE O N �j 1 c GNA UZ RE r `0 Q V- U 11 Date JUNE 14, 2017 Map of a Survey made for (� e ' 1° UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY - - J,co.� -, ,,,. - MAP BEARING A LICENSE LAND SURVEYORS SEAL ISA Y y - VIOLATION OF SECTION 72U9,SUB-DIVISION 2,OF THE NEW YORK STATE EDUCATION LAW." me -ves = "ONLY COPIES FROM¶IE ORIGINAL OF THIS SURVEY - " = MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS _ - - Ifly - SEAL SHALL BE CONSID€tiED TO BE VALID TRUE COPIES." I CERTIFICATIONS PREPARED HEREON SIGNIFY THAT `ti R. 'q/9 y'�'y ry THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE - Michael Jarvis i Is - 7 EXISTING CODE OF PRgg jICE FOR LAND SURVEYORS ADOPTED _ - ONAL ir-ve i� LAND BY HSURVEYORS.SA19 EERTIE NEW YORK STATE FlCATIONS SHALL CIATION OF ORUN SIONLY = y/ _ SHEET 1 OF 1 TO THE PERSON FOR V,,116M THE SURVEY IS PREPARED,AND = ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL - 169 Haviland Road Queensbury New York 12804 AGENCY AND LENDING INSTITUITION LISTED HEREON,AND Town of Queensbury, Warren County, New York 6. TO THE ASSIGNEES OF TfIE LENDING INSTITUTION." - Qo(1 (518) 792--8474 New York Lic. No. 50135 DWG. NO. 17050 NO DATE „_ . DESCRIPTION ...... .... . ........ w. ., .W,.,. .,.,_ .. �.......w._�� 316. 10-1-51 DEED REFERENCE. -- -— IPF ROBERT E. MCDONALD TO MI CHAEL R. JARVIS __-- DATED MARCH 10, 2017 IPF IN BOOK 5524 PAGE 50 FN MAP REFERENCES: IPFDRIVE ® IPF MAP OF A SURVEY MADE FOR COBY TOWN OF QUEENSBURY CiRF DATED MARCH 25, 1996 - o IPF BY VAN DUSEN & STEVES N 86017'0511 E v CIRS o IPF MAP SHOWING LANDS CONVEYED BY 165.00 w MARY A. HOPKINS, WIDOW OF - REUBEN W. HOPKINS TO l ' a OWEN _BALL AND MABEL V. BALL E o ti DATED AUGUST 11, 1941 .� BY COUL TER & ASHLEY + .� PROPANE TANK 58.8' Q w PA r I 0 1 STORY _ w LANDS OF ' WOOD FRAME N r. MARGARET MCDONALD EC 2 0 2017 - _ HOUSE a' CM Q) CMC"'3 Ad�t iniis tretcr rn o V Q QUEEwS �R ,us. WINDOW r- w WELL r C6 rco LEGEND: '.� 316. 10-1-51 32535.3 Sq. Feet 0. 74 Acres IPF = IRON PIPE FOUND D ' E E IRF = IRON ROD FOUND i 2 nn CIRF = CAPPED IRON ROD FOUND DEC CIRS = CAPPED IRRON ROD SET TOWN OF QUEE SIBURY IPF IPF BUILDING&C CUES ' 1-1/4" IPF �-, _ UTILITY POLE � 160.651, 1_1/q." IPF8700110811 ,_._.. S 87001 '0811 W { oV NF�v FINAL 6 U V EY LANDS OF �,. SANDRA JARVIS 0 35 AC c � -N DR Date- JUKE 14, 2017 Scale f Dus 'UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY �+ �s for J`C a t e 1 J O MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A Map dl a Survey made or VIOLATION OF SECTION 7209,SUB-DIVISION 2,OF THE S 1 'J� e s NEW YORK STATE EDUCATION LAW.- "ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS s 4 12113117 FINAL SURVEY SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.* 'CERTIFICATIONSSURVEY WAS INDICATED HEREON SIGNIFY THAT y c a e l RA Jarvis j�r�^THIS SURVEY.WAS PREPARED tN ACCORDANCE WITH THE 1 3 8130117 BAK r� CERT'�'�A Ti(Ol}YJ EXISTING CODE OF PRACTICE FOR LAND SURVEYORS PROFESSIONAL ADOPTED J Laiad Siir-ve -v(D X Z-456 LANDBY THE NEW PORK STATE ASSOCIATION OF PROFESSIONAL TO SURVEYORS,SAID CERTIFICATIONS SHALL RUN ONLY 8 TITLE COMPANY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND / SHEET 1 ®F 1 i (� j�' a a 7., '�7 s] (g ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL a'{� ,/ SHEET 1 i- 1 69 Havlland Road Queens bury, New York 1 2804 AGENCY AND LEES O ITHE LENDING LISTED HEREON,AND Town of Queensbury, Warren Count, New York 1 811511� FOUNDATION LOCATION TO THE ASSIGNEES OF THE LENpING INSTITUTION." JARVIS C--3096 (518) 792--8474 New York Lic, No. 50135 NO. DATE DESCRIPTION DWG. NO. 17050 316. 10-1-51