Loading...
RC-000802-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 -- Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000802-2016 Date Issued: Thursday, June 22, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000802-2016 has been completed. Tax Map Number: 296.14-2-3 Location: 25 DEVIN CT Owner: CERRONE BUILDERS,INC. Applicant: CERRONE BUILDERS, INC. This structure may be occupied as a: Single Family Dwelling w/FP 1400 s.f. Garage 844 s.f. By Order of Town Board Village at Sweet Road,Lot 3 TOWN OF QUEENSBUR,Y/ Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&,Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road.Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000802-2016 Tax Map No: 296.14-2-3 Permission is hereby granted to: CERRONE BUILDERS,INC. For property located at: 25 DEVIN CT In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: CERRONE BUILDERS,INC. Single Family-New $340,000.00 Owner Address: 1589 State Route 9 Total Value $340,000.00 Fort Edward,NY 12828 Contractor or Builder's Name/Address Electrical Inspection Agency CERRONE BUILDERS,INC. 1589 State Route 9 Fort Edward,NY 12828 Plans&Specifications Single Family Dwelling w/FP 1400 s.f. Garage 844 s.f. Village at Sweet Road,Lot 3 $1,306.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,December 8,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town pfQRCet bury; _In 4 Th say ece ber 8,2016 SIGNED BY: `( Limit{// for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL 8-1-RU "1'UKE APPLICATION Office Use Only Date: Z f Z9 Permit No. (LC -602• ZO 110 Tax Map ID / Permit Fee 5to• -0 t1.0.. Zone . �H/1istooriri'c? _Yes /No Rec Fee Subdivision Name '//Nf /��.�lG>!C/ cLC Lot# _ Site Plan# Subdivision# Project Location AL5- /iu �� ALA'3 TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address Phone/Email Applicant Address Phone/Email Contractor Address Phone/Email Contact Person for Building&Codes Compliance: .96dGn/ Lily /n i Phone TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration la floor sf 2nd floor sf Total sf Height Single Family Two-Family 7(J Multi-Family (#of units_) Townhouse Business Office 15 Retail-Mercantile TOWN OF QUEENSB RY BUIL ING&CODE Factory-Industrial Attached Garage (1, 26)4+) Other ` 7 Town of Queensbury Building&Codes Principal Structure Application revised January 2016 'I f commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? Site Information: a. Dimensions or acreage of lot I b. Is this a corner lot? _Yes No c. Will the grade be changed as a result of construction Yes ✓ No d. Public water or Private well(circle one) Public Private e. Sewer or Private Septic System(circle one) Sewe Private Value of all work to be performed (labor or materials) $ 60 0f DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: / /J �.L� /1�t� DATE: SIGNATURE: DATE: �� l•% �6 For office use only Operating Permit Issued: —Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office use Only / Received DATE: 11127 Z l6 Tax Map ID TAx MAP ID: Permit No. 2 . 2o l b Permit Fee ZONE: OWNER �� / PHONE/E-MAIL -V/- ADDRESS INSTALLER/ PHONE/E-MAIL BUILDERi�G�/�/QGL CO CONTACT PERSON FOR BUILDDING&CODE COMPLIANCE: PHONE/E-MAIL � / , e! jnl BUILDING ADDRESS z ��N ROOM OF INSTALL: �a/ �!'h� , PLANNED INSTALL DATE: 6r,4 1• ZA9/7 FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT Vi LL REQUIRED' NOTE: FIREPLACE,FACTORY BUILT* 20116 t OV j 1 20 MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) I QVVII OF Out BUI DING& ODES Y MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: e/ / c, ;Model#: 11M 310 Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) _BLOCK _BRICK _STONE Flue YIE STEEL Size in inches Material DOUBLE WALLTRIPLE WALL INSULATED _ ** If non-masonry provide manufacturer name: ! a-- ;Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: / PRINTNAME: DATE: A SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Ho p t� � od � DRIVEWAY PERMIT D Date: Zz 6 NOV 2 1 2016 Applicant Name: 0W— r TOWN OF QUEENSSURY BUILDING&CODES Telephone No.: �j f '�QL�//Z/� Address to be Inspected z5- 1-loll Return Address: , o�G Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: O Preliminary approval 296.14-2-3 RC-000802-2016Cerrone Builders NEED ( ) Slight Swale 25 Devin Court, Lot 3 ( ) Deep Swale SFD W/FP 1400 s.f.,Garage 844 s.f. O Level with the road - ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24„ ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 /off EE tNbIJURY BUILDING&CODES ' I Nil1 � I / �7 90' zs ; REScheck Software Version 4.6.2 Compliance Certificate 296.14-2-3 RC-000802-2016 Project Cerrone Builders Inc Cerrone Builders Energy Code: 2015 IECC 25 Devin Court, Lot 3 Location: warren County, New York SFD w/FP 1400 s.f.,Garage 844 s.f. Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,400 ft2 Glazing Area 14% FILE COPY Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 25 Devin Court VISION Engineering, LLC Lot 3 206 Glen Street Queensbury, NY 12804 Suite 56 Glens Falls, NY 12801 (518) 792-9264 Compliance: Passes using UA trade-off Compliance: 0.0%Better Than Cade Maximum UA: 223 Your UA: 223 The%Better or worse Than Code Index reflects haw close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. U-Factor UA Ceiling 1: Raised or Energy Truss 1,400 38.0 0.0 0.025 35 Wall 1: Wood Frame, 16" o.c. 1,404 21.0 0.0 0.057 68 Window 1: Vinyl Frame:Double Pane with Low-E D EC E BY Y E 139 0.290 40 Door 1: Front: Solid �p V 0 0.200 4 Door 2: Back: Glass 2 l c 0 0.290 12 NOV Door 3: Fire Door: Solid , 2015 8 0.140 3 Basement Wall 1: Solid Concrete or Masonry 13 D0 0.0 15.0 0.046 54 Wall height: 7.8' TOWN OF QUEENSBURY Depth below grade: 6.8' BUILDING 8 CODES Insulation depth: 7.8' Window 2: Wood Frame:Double Pane 7 0.320 2 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.320 5 Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES - Page 1 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck VersiTM mply with the mandatory require is listed in the REScheck Inspection Chet ist. f Name-Title Signature DJP VU Project Notes: VISION Project 1201 OF NFw LW q y y0 Ar: w z 40 0 311 Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES- Page 2 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck CREScheck Software Version 4.6.2 �J( Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions' column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection Review Value Value Complies? Comments/Assumptions & Re .ID - 103.1, .Construction drawings and - ❑Complies 103.2 ''documentation demonstrate ❑Does Not [PRM energy code compliance for the Al :building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems ❑Not Observable Systems serving multiple ❑Not Applicable !dwelling units must demonstrate , compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr— ❑Does Not [PR212 on loads calculated per ACOA Cooling: Cooling: Manual J or other methods Btu/hr— Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201- DES - Page 3 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R- R- ❑Does Not table for values. 4Y, insulation is used,verification ❑Not Observable may need to occur during ❑Not Insulation Inspection. Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F0511 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable j 402.2.9 !Conditioned basement wall ft it ❑Complies See the envelope Assemblies [FO611 linsulation depth of burial or ❑Does Not (table for values. distance from top of wall. ❑Not Observable ❑Not Applicable j 30321G A protective covering is installed ❑Complies [FO110 'to protect exposed exterior ❑Does Not insulation and extends a ' ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 4039 . . ..Snow-and ice-melting system ❑Complies [FO12]2'" controls installed. ❑Does Not ❑Not Observable ❑Not Applicable j Additional Comments/Assumptions: 111 High Impact(Tier 1) r 'u Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\I rob ision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES - Page 4 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Plans Verified 'Field Verified' # Framing / Rough-In Inspection Value Value Complies? 'Comments/Assumptions & Rep.ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 ❑Not Observable . []Not Applicable 402.1.1, .Glazing U-factor(area-weighted U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.1, '.average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Nat Observable 402.5 E]Not Applicable j [FR211 303.1.3 :U-factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. r : ❑Not Observable I _ ❑Not Applicable 402.4.1.1 .Air barrier and thermal barrier _ ❑Complies [FR2311 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable j 402.4.3 '.Fenestration that is not site built ❑Complies [FR20]3 -is listed and labeled as meeting ':' ❑Does Not 'AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 1400 that do not exceed code ❑Not Applicable limits. 402.4.5 '..IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not j and labeled to indicate <_2.0 cfm -]Not Observable ;leakage at 75 Pa. ❑Not Applicable j 403.2.1 Supply and return ducts in attics []Complies (FR1211 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where < 3 inches.Supply and return ducts in other portions of ❑Not Applicable j the building insulated>= R-6 for diameter>= 3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ,ducts or plenums. ❑Does Not e3 ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R-_ R-_ ❑Complies (FR17]' above 105 QF or chilled fluids - ❑Does Not below 55 4F are insulated to all- []Not Observable _ 3. ❑Not Applicable j 403.4.1 Protection of insulation on HVAC ❑Complies [FR2411 piping. ❑Does Not M ❑Not Observable ❑Not Applicable j 403.5. -7 Hot water pipes are insulated to R-_ R-_ ❑Complies [FR18]2 '>_R-3. ❑Does Not M) ' ❑Not Observable ❑Not Applicable j 403.6 .Automatic or gravity dampers are ❑Complies [FR19]2 Jinstalled on all outdoor air :]Does Not sill intakes and exhausts. :]Not Observable :]Not Applicable 1 I High Impact(Tier 1) Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201- DES - Page 5 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) -2- Medium Impact(Tier 2) 3.1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201- DES - Page 6 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Field Verified # Insulationinspection Plans Verified Value Value Complies? Comments/Assumptions 303.1 All installed insulation is labeled "❑Complies [IN13]2 or the installed R-values -❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R-_ El Co 'See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the [I Wood F1 Wood Do=Not table for values. 402.2.6 wall insulation on the wall ❑ Mass j❑ Mass ❑Not Observable [I1,13]1 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Mall insulation is installed per ;❑Complies [IN411 `.manufacturer's instructions. ❑Does Not ❑Not Observable - ❑Not Applicable Additional Comments/Assumptions: ---------- 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES- Page 7 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req,ID 402.1.1, .Ceiling insulation R-value. R- R- ❑Complies :See the Envelope Assemblies 402.2.1• E] Wood ❑ Wood ❑Does Not 'table for values. 402.2.2• ❑ Steel ,❑ Steel ❑ 402.2.6 Not Observable [Fill' ❑Not Applicable 303.1.1.1, ;Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every 1300 ft'. ❑Not Observable ❑Not Applicable 4022, Vented attics with air permeable ❑Complies [F1227z::•.—:insulation include baffle adjacent ❑Does Not to soffit and eave vents that ;extends over insulation. ❑Not Observable c =❑Not Applicable 402.2.4 Attic access hatch and door '. R-_ R-_ ❑Complies [FI311 insulation all-value of the r ❑Does Not :.adjacent assembly. ❑Not Observable j❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 : ACH 50 =_ ACH 50 =_ ❑Complies [FI1711 Tach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable i 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI411 -cfm/100 ft2 across the system or : ft2 ft' []Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to - ❑Not Applicable j 'occur during Framing Inspection. 403.3.2 :Ducts are pressure tested to cfm/100 cfm/loo ❑Complies [FI2711 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total :❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable :w.g.across the system including :the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total .leakage measured with a pressure differential of 0.1 inch -w.g.across the entire system including the manufacturer's air handler enclosure. 403,3.2.1 :Air handler leakage designated ❑Complies [F12411 r by manufacturer at<=2%of ❑Does Not :design air flow. ❑Not Observable ; ❑Not Applicable 4U20,�,Programmablethermostats ❑Complies installed for control of primary ❑Does Not heating and cinitially set by manufacturer to ❑Not Observablecode specifications. ❑Not Applicable ,. Heat pump thermostat installed ❑Complies : on heat pumps. ❑Does Not - n ❑Not Observable ❑Not Applicable Circulating service hot water ❑Complies systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2'-` Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES- Page 8 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & RegAD 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and airflow limits. -❑Not Observable ❑Not Applicable j 403.2 Hot water boilers supplying heat ❑Complies [F12612 through one-or two-pipe heating El Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor []Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F12812 have a circulation pump.The []Does Not system return pipe is a dedicated ❑Not Observable I return pipe or a cold water supply: pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal 1 for hot water demand within the ` 1 occupancy.Controls automatically turn off the pump when water is in circulation loop _ is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies (F12912 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable i desired water temperature in the - piping. - 403.5.2 Water distribution systems that ❑Complies [F13012 have recirculation pumps that El Does Not j pump water from a heated water - ❑Not Observable 1 supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F13112 tested in accordance with CSA ❑Does Not 855.1.Potable water-side ❑Not Observable pressure loss of drain water heat recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps., ❑Not Observable Does not apply to low-voltage 'lighting. ❑Not Applicable j 404.1.1 Fuel gas lighting systems have ❑Complies [F12313 no continuous pilot light. ❑Does Not u ❑Not Observable ', ❑Not Applicable 1 High Impact(Tier 1) 2] Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201 - DES - Page 9 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Compliesi Comments/Assumptions & Req ID _ __ 401.3 Compliance certificate posted. ❑Complies [FI712 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18)3 'mechanical and water heating ❑Does Not systems have been provided. []Not Observable ❑Not Applicable j Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 11/21/16 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1201- DES- Page 10 of 10 Cerrone Devin Court Lot 3\1201 Rescheck.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating System: Cooling System: Water Heater: Name: Date: Comments _ . NOV 2 1 2016 TOWN OF QUEENSSURY BUILDINGi LAW a Q cc1� I`7 i �zs � 296.14-2-3 RC-000802-2016 Cerrone Builders 25 Devin Court, Lot 3 SFD w/FP 1400 s.f.,Garage 844 s.f. Manu>Uan comdpil is ce pepo r Job: 2 Date: Dec O5,2016 Entire House By: CERRONE Plan: 59 devin Project • • For: CERRONE,A CERRONE f���V //V C QUEENSBURY, NY 12865 cooling Design Conditions Outdoor design DB: 85.0°F Sensible gain: 36025 Btuh Entering coil DB: 72.0°F Outdoor design WB: 71.0°F Latent gain: 9116 Btuh Entering coil WB: 60.1°F Indoor design DB: 72.0'F Total gain: 45140 Btuh Indoor RH: 50% Estimated airflow: 1560 cfm Manufacturers Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: CZF04814C+FC48C3XC1+TM8VO8OC16MP11+S1-1TVM4N1 Actual airflow: 1550 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment— Design • •Design Conditions Outdoor design OR -4.0°F Heat loss: 104336 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F p EC 1E9WE Manufacturer's Performance Data at Actual Design Conditions L ; Equipment type: Gas furnace TOWN OF QUEENSBURY Manufacturer: York Model: TM9X120D20MP11 BUILDING& CODES Actual airflow: 1550 cfm Output capacity: 114000 Btuh 109% of load Temp, rise: 50 OF FILE COPY Meets are all requirements ofACCA Manual S. ,- - wri htsoft° Right-Suite®Universal 201717.0.16 RSU25116 2016-Dec-07 08:33:02 ACCA ...slScott.langewanhylDDcumentslYork%Projecl2.mp Calc=MJ7 Front Door faces: N Page 1 ResidentialPlans Review Form Form RIPER 1 ACCK for Desi•n (Loads, E• • 15 Mar 09 u�um,a�coaxv:narem QUEENSBURY Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes I—] NoE-1Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes No Building plan#: 59 Bevin Manual D Friction Rate Worksheet: Yes No Home address(Street or Lol#,Block,Subdivision): , Entire House Duct distribution sketch: Yes E] No I—] • .DCALCULATION Design Conditions Building Construction Information Winter Design CondlUons Building Outdoor temperature: -4 °F Orienttion: Front Door faces North Indoor temperature: 70 of North,East,West,South,Northeast,Northwest,Southeast,southwest Total heat loss: 104336 Btuh Number of bedrooms: 3 Conditioned floor area: 2780 ft' Summer Design Conditions Number of occupants: 36 Outdoor temperature: 85 °F Indoor temperature: 72 °F Windows Roof Grains difference: 33 gr/Ib @50% RH Eave overhang depth: 0 it Sensible heat gain: 40027 Btuh Internal shade: none Eava Latent heat gain: 10128 Btuh Blinds,drapes,etc. Oeplp wmdo. Total heat gain: 50156 Btuh Number of skylights: 0 EQUIPMENTHVAQ • 1 Heating Equipment Data Cooling Equipment Data Blower Data Equipment t�a, Gas furnace E%igment type SpIitAC Healing cfm: 1550 umaca,Ne pump,Boller,etc. Ir ondkloner,neat pump,etc. Cooling aft 1550 Model: York Model: York Static pressure: 0 in H2O TM9X120D20MP11 CZF04814C Fans rated external static pressure for design airflow Heating output capacit 11417r100 Bluh Total cooling capacity: 0 Btuh Neat pumps•capacity at InterEeslpnouC000rcondhmns Sensible cooling capacity. 0 Btuh Aux.heating output capacity 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M16• Design airflow: 1550 chilli Longest supply duct: 254 it Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 74 It Trunk duct: Sheet metal Total device pressure losses: 0 in H2O Total effective length(TEL): 328 ft Available static pressure(ASP): 0 in H2O Friction rate: Friction Rete=ASP+iTELx IOL)((�1 iN100ft Branch duct: Sheet metal declare the load calculation,equipment,equipment selectionand duct design were rigorously performed based on - building plan listed above. I understand the claims made on these forms will be subjectto review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County.Tomn Nli-�cipal:ty orAuthority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist + wrightsoft' RightsuheO universal 2017 17X.16 RSU25116 Load Short Form Job: 2 Date: Dec 05, 2016 Entire House By: C E R RO N E Plan: 59 devi n • 161911APM16311 For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Information Htg Clg Infiltration Outside db(°F) -4 85 Method Simplified Inside db(°F) 70 72 Construction quality Best Design TO (°F) 74 13 Fireplaces 1 (Best) Daily range - M Inside humidity (%) 30 50 Moisture difference(gr/Ib) 29 33 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK Trade AFFINITY Model TM9X120D20MP11 Cond CZF04814C AHRI ref 2008696 Coil FC48C3XC1+TM8V08oCl6MPJJ+S1-ITVM4N1 AHRI ref 5561866 Efficiency 95.5AFUE Efficiency 12.3 EER, 14 SEER Heating input 120000 Btuh Sensible cooling 32550 Btuh Heating output 114000 Btuh Latent cooling 13950 Btuh Temperature rise 67 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.015 cfm/Btuh Air flow factor 0.043 cfrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF W) (Btuh) (Btuh) (cfm) (cfm) MASTER BEDROOM 204 9989 3193 148 137 MASTER BATH 66 6863 1926 102 83 WIC 55 2450 1413 36 61 ENTRY 48 3504 1556 52 67 CLOSET 20 1480 1393 22 60 BEDROOM 3 144 7478 2980 111 128 BEDROOM 2 100 8928 2896 133 125 BATH 54 2794 1456 42 63 KITCHEN/GR 689 19605 3953 291 170 BASEMENT 1400 41246 15258 613 657 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsott" 2016-Dw-0708:33:02 9 MghtSuile®Universal 2017 17.0.16 RSU25116 Page 1 AM ...slscott.lang"onhy\Documents\York\Pmject2.mp CWC=MV Front Door faces: N Entire House d 2780 104336 36025 1550 1550 Other equip loads 0 0 Equip. @ 0.90 RSM 32422 Latent cooling 9116 TOTALS 2780 104336 41538 1550 1550 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsoftRight.Sude®Univetsa1 201717.0.16 RSU25NPage 2016-Oft-077 08 age 2 2 SCA ...s\scoff.langeworthy\DocumentslYoficlProject2.rop CeIc=MJ7 Frorn Door faces: N Building AnMysis Job: 2 Date: Dec OS, 2016 Entire diocese By: GERRONE Plan: 69devin ��-.Gilact InformationFor: CERRONE,A CERRONE OUEENSBURY, NY 12865 Desicin Conditions Location: Indoor: Heating Cooling Glens Falls AP NY US Indoor temperature (°F) 70 72 Elevation: '335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humi lty (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F -4 85 Infiltration: Wety ranle�F) _ 20 ( M ) Method Simplified ( Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Heating Component Btuh/ft2 Btuh % of load Walls 16.4 41751 40.0 Ducts Glazing 26.7 4343 4.2 DuInfiltration Doors 30.3 1166 1.1 Ceilings 21.5 30151 28.9 Walls Floors Floors 11.4 15966 15.3 Infiltration 29.8 5991 5.7 Ducts 4968 4,8 Piping 0 0 Humidification 0 0 Glazing Ceilings Ventilation 0 0 Other Adjustments 0 Total 104336 100.0 • • 11• Component Btuh/ft2 Btuh % of load Walls 1.7 4375 12.1 Glazing 30.7 4986 13.8 Walls Doors 6.8 262 0.7 Ceilings 10.8 15075 41.8 Internal Gains Floors 0 0 0 Glazing Infiltration 2.6 526 1.5 ether Ducts 0 0 Ventilation 0 0 Internal gains 10800 30.0 Blower 0 0 s Ceilin Adjustments 0 9 Total 36025 100.0 Latent Cooling Load= 9116 Btuh Overall U-value= 0.267 Btuh/ft'--°F WARNING: window to floor area ratio= 5.8% - less than 10%. WPI tltsof- g 2016-Dec-07 08:33:02 RI 9 hl-Sufte®universal 2017 17.0.16 RSU25116 Page 1 / +C.�A ...slswtt.langewonhylDocuments%YorklProject2.mp Calc=MR Front Door feces: N Component Constructions jDaatt e: Doc 05, 201E Entire House By: CERRONE Plan: 59 devir, Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) r�rrYrlianrr--- - - - - - Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain BWh/ --'F fl'-TF h BWNR` BWh SWOV BWh Walls 12MO:Frm wall,vnl ext,3/8"wood shth,r-21 cav ins, 1/2"gypsum 72 0.037 27.0 2.74 196 0.61 44 board int fnsh,r-4 ext bd ins,2"x6"wood frm,16"o.c.stud 12MO:Frm wall,vnl ext,1/2"wood shlh,r-21 cav ins,1/2"gypsum 377 0.037 27.0 2.74 1032 0.61 232 board int fnsh,r-4 ext bd ins,2"x6"wood frm,16"o.c.stud 14AO:Blk wall,stucco ext,8"thk,vermiculite core,1/2"gypsum 864 0.510 0 37.7 32623 4.74 4100 board int fish 15EO:Bg wall,light dry soil,2"x4"wood Int frm,concrete wall,r-13 1227 0.087 0 6.44 7899 0 0 cav ins,10"thk Partitions (none) Windows 3D0:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 73 0.361 0 26.7 1950 17.6 1285 1/4"thk;6.67 ft head ht a 15 0.361 0 26.7 401 62.6 939 ' S 60 0.361 0 26.7 1592 30.6 1823 W 15 0.361 0 26.7 401 62.6 939 all 163 0.361 0 26.7 4343 30.7 4986 Doors 10DO:Door,wd so type 18 0.460 0 34.0 596 7.64 134 1180:Door,mil fbrgl type,mtl strm 21 0.367 6.3 27.2 570 6.09 128 Ceilings C pa:C part ceiling,hrd wd fir fnsh,frm fir,6"thkns 1400 0.291 1.0 21.5 30151 10.8 15075 Floors 19AO:Part floor,hrd wd fir fnsh,frm fir,6"thkns 1380 0.312 0 11.5 15931 0 0 21AO:Bg floor,heavy dry or light damp soil,6'depth 20 0.024 0 1.78 36 0 0 2016-Dec-07 08:33:02 ,it, + wrightsoft Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 AEUK ...s\scatt.langmorthylDocuments%YorklProject2.mp Calc=MH Front Door faces: N Component Constructions Job: 'L Date: Dec 05,1096 MASTER BEDROOM By: CERRONE Plan: 59devin Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 CQnditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 it Design TD (°F) 74 13 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range("F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain W BtuhlR'-F ff.-FIBluh B hlfl' Duh BWhM BNh Walls 12MO:Frm wall,vnl ext, 1/2"wood shth,r-21 cav ins, 1/2"gypsum 93 0.037 27.0 2.74 255 0.61 57 board int fnsh,r-4 ext bd ins,2"x6"wood frm,16"o.c.stud 14AO:Blk wall,stucco ext,8"thk,vermiculite core,1/2"gypsum 138 0.510 0 37.7 5208 4.74 655 board int fnsh Partitions (none) Windows 3D0:2 glaang,clr outr,air gas,vnl frm mat,cir low-e innr,1/4"gap, n 15 0.361 0 26.7 401 17.6 264 1/4"thk;6.67 it head ht w 15 0.361 0 26.7 401 62.6 939 all 30 0.361 0 26.7 801 40.1 1203 Doors (none) Ceilings (none) Floors 19A0:Part floor,hrd wd flr fnsh,frm flr,6"thkns 204 0.312 0 11.5 2355 0 0 wri httsofl° 2076-Dec-0733 g RightSude®Unlversa12017 17.O.t6 R6U25176 Pae 2 11CCP. ...s\scott.langmorthy\Documents%YorklProject2.mp Calc=MJ7 Front Door faces: N 0 Component Cons'tIY0.tlC'dons- Job: 2 Date: Dec 05, 2096 MASTER BAM By: CERRONE ERRONE Plan: 59 devin Project Information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BWhV-'F ft'-'FMWh BWhlft' BWh 9WhH' BWh Walls 14AO:Blk wall,stucco wd,8"thk,vermiculite core,1l2"gypsum 153 0.510 0 37.7 5774 4.74 726 board int fish Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19AO:Part floor,hrd wd Or fnsh,frm fir,6"thkns 66 0.312 0 11.5 762 0 0 2016-Dec-07 00:33:02 rt wrilghtsoft• Right-SufteO univemal201717.0.96 RSU25116 Page 3 .91.E ...s\scoff.langmorlhy\DocumentslYork\Pmject2.mp Cale=M.17 Front Door faces: N UateCom ement Constructions- .ae : Doc 05, 2016 w/c By: GERRONE Plan: 59 devirr Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed(mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions or Area U-value Insul N Htg HTM Loss Clg HTM Gain W Btuhfitz T ft''FiStuh BIuhHP Btuh ROM, Btuh Walls 14AO:Bilk wall,stucco ext,8"thk,vermiculite core,1/2"gypsum 45 0.510 0 37.7 1698 4.74 213 board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19AO:Part floor,hrd wd fir fnsh,frm fir,6"thkns 55 0.312 0 11.5 635 0 0 wri htSOfY 2016-Dec-07 08:age 4 9 Right-Saha®Universal 201717.0.16 RSU26116 Page 4 /ICCh ...slscott.langmorthyk0mumentslYork%Pmfect2.mp Calc-MJ7 Front Doer faces: N job: 2 Component construe'aron's Byte: Dec05, 2016 ENTRY G E R RO N E Plan: 59 devin ijProject information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U•value Insul R Htg HTM Loss Clg HTM Gain ft' BWhW-'F W-TF h BtuhM BWh BWMn Bluh Walls 12MO:Frm wall,vnl ext,3/8"wood shlh,r-21 cav ins, 1/2"gypsum 24 0.037 27.0 2.74 66 0.61 15 board int fnsh,r-4 ext bd ins,2"x6"wood frm, 16"o.c.stud 14AO:Blk wall,stucco ext,8"thk,vermiculite core, 1/2"gypsum 72 0.510 0 37.7 2717 4.74 341 board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19AO:Part floor,hrd wd flr fnsh,frm fir,6"thkns 48 0.312 0 11.5 554 0 0 2016-Dec-07 06:33:02 wrrgtltSOft" Right-S,%,®Universal 2017 17.0.16 RSU25116 Page 5 ACCl4 ...s\scott.langewo0hy\Documents\York\Project2.mp Calc=MJ7 FrontDoorfaces: N Job: 2 Component Constructions Dae: Dec 05,2016 CLOSET By: CERRONE Plan: 59 devin Project information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Dally range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain fP Btu MY--'F fl'-'FI8Wh BWhA? BWh fl.W GWh Walls 12MO:Frm wall,vnl ext,3/8"wood shth,r-21 cav ins, 1/2"gypsum 23 0.037 27.0 2.74 62 0.61 14 board int fnsh,r-4 ext bd ins,2"x6"wood frm,16"o.c.stud Partitions (none) Windows (none) DOOR 10DO:Door,wd sc type 18 0.460 0 34.0 596 7.64 134 Ceilings (none) Floors 19AO:Part Floor,hrd wd 0r fnsh,frm 0r,6"thkns 20 0.312 0 11.5 231 0 0 2016-Dec-07 06:33:02 wrightS01fr RlghtSunes Universal 2017 17.0.16 RSU25116 Page 6 . .a1 ...s%scott.tangmonhy%Documents%York%Prolect2.mp Calc=MJ7 Fr°nt Doorfaces: N Component Constructions Dab: Date: Dec 05, 201E BEDROOM 3 By: GERRONE Plan: 59 devir: Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Qesign Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb ("F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions or Area u-value Insul R Htg HTM Loss Clg HTM Gain W BWhff-'F I --FIBNh BWhM' BWh 2whff BWh Walls 12M0:Frm wall,vnl ext, 1/2"wood shlh,r-21 cav ins, 1/2"gypsum 93 0.037 27.0 2.74 255 0.61 57 board int fish,r-4 ext bd ins,2'x6"wood frm,16"o.c.stud 14AO:Bilk wall,stucco ext,8"thk,vermiculite core,1/2"gypsum 93 0.510 0 37.7 3510 4.74 441 board int fish Partitions (none) Windows 3130:2 glazing,clr ,outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 15 0.361 0 26.7 401 17.6 264 1/4"thk;6.67 ft head ht a 15 0.361 0 26.7 401 62.6 939 all 30 0.361 0 26.7 801 40.1 1203 Doors (none) Ceilings (none) Floors 19AO:Part Floor,hrd wd flr fnsh,frm Or,6"thkns 144 0.312 0 11.5 1662 0 0 $ ht'SOfC 2016-Dec-07 08:age 7 Wrl 9 RIgMSuke®UnNersa12017 77.0.18 RSU26116 Page 7 ...s\scott.langewonhy\Doouments\York\Pmject2.mp Calc=MJ7 Front Doorfaces: N job: 2 Component Concstruc0col(11u Date: Dec 05,201E BEDROOM 2 By: C E RRO N IE Plan: 59 devin Project Information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Qesign Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain R aWhM-'F R'-'F/Bluh BWhM' BWb BWhtlt' BWh Walls 14AO:Blk wall,stucco ext,8"thk,vermiculite core, 1/2"gypsum 150 0.510 0 37.7 5677 4.74 713 board int fnsh Partitions (none) Windows 3D0:2 glazing,Or outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, s 30 0.361 0 26.7 790 30.6 905 1/4"thk;6.67 ft head ht Doors (none) Ceilings (none) Floors 19AO:Part Floor,hrd wd Or fnsh,frm Or,6"thkns 100 0.312 0 11.5 1154 0 0 2016-Dec-07 06'.33'02 wrightsofr Right-Su te®Universal 2017 17.0.16 RSU25116 Page 8 .4CCp. ...slscotl.langeworthy\DocumentslYork\Project2,mp Calc=MJ7 Front Door faces: N Cort onent Constructions Jeb 21BATH Byte: Dec 05, ?01'0 CERRONE Plan: 59 devir; _ Project Information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions-______ Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb ( F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft BWh&--'F °'-'Fl6tuh 6!uhd' BUh Etuhrlt' BWh Walls 14AO:&k wall,stucco ed,8"thk,vermiculite core,1/2"gypsum 54 0.510 0 37.7 2038 4.74 256 board intfnsh Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 19AO:Part Floor,hrd wd fir fnsh,frm fir,U'thkns 54 0.312 0 11.5 623 0 0 33 02 + wrightSOft' RIghP6uHeO Universal Zan n.D.16 Rsu25116 2016-Dec-07 0 Page 9 Z51 ...stscott.lang..Ahy\Dacuments%York\Project2.mp Cale=MJ7 Front Door faces: N Coot onent Constructions Dob: ? Date: Dec 05, 209E KITCHENIGR By: CERRONE Plan: 59 devir, Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design Conditions - Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature("F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 430N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.1 33.4 Dry bulb (°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed(mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cie HTM Gain ft' 6NhN.-F V-TATA BUMP BWh amnm' BUh Walls 12MO:Fan wall,vnl ext,3/8"wood shth,r-21 cav Ins,1/2"gypsum 25 0.037 27.0 2.74 68 0.61 15 board int fnsh,r-4 ext bd ins,2'x6"wood frm,16"o.c.stud 12MO:Fnn wall,vnl at,1/2"wood shth,r-21 cav Ins,1/2"gypsum 191 0.037 27.0 2.74 523 0.61 117 board int fnsh,r-4 ext bd ins,2"x6"wood frm,16"o.c.stud 14AO:Blk wall,stucco ext,8"lhk,vermiculite core,1/2"gypsum 159 0.510 0 37.7 6001 4.74 754 board int fnsh Partitions (none) Windows 3D0:2 glazing,clr outr,air gas,vnl frm mal,clr low-e innr,1/4"gap, n 43 0.361 0 26.7 1149 17.6 757 1/4"thk;6.67 R head ht s 30 0.361 0 26.7 801 30.6 918 all 73 0.361 0 26.7 1950 22.9 1675 Doors (none) Ceilings (none) Floors 19AO:Part Floor,hrd wd 8r fish,frm Or,6"Mrs 689 0.312 0 11.5 7954 0 0 2016-De -0708:33:02 wri hft0ft- RIgM-Softs®UnMersel 201717.0.16 RSU26116 Page 10 ...s\Scott.longmarthy\Document\York\Prolect2.mp Calc=MJ7 Front Dow faces: N Coorunt Constvli efoons Job: 2 Com Date: Dec 05,2096 BASEMENT By: CERRONE Plan: 59 devin Project • • For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Design CQnditions, Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 72 Elevation: 335 ft Design TD (°F) 74 13 Latitude: 43°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 29.1 33.4 Dry bulb (°F) -4 85 Infiltration: Daily range (°F) - 20 ( M ) Method Simplified Wet bulb (°F) - 71 Construction quality Best Wind speed (mph) 15.0 7.5 Fireplaces 1 (Best) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain M 3uhV-'F M1?'Fratuh BluhV DO i3NW auh Walls 15EO:Bg wall,light dry soil,2"x4"wood int frm,concrete wall,r-13 1227 0.087 0 6.44 7899 0 0 cav ins,10"thk Partitions (none) Windows (none) Doors 11BO:Door,mtl fbrgl type,mtl strm 21 0.367 6.3 27.2 570 6.09 128 Ceilings C pa:C part ceiling,hrd wd Or fnsh,frm flr,6"thkns 1400 0.291 1.0 21.5 30151 10.8 15075 Floors 21AO:Bg floor,heavy dry or light damp soil,6'depth 20 0.024 0 1.78 36 0 0 Wrl I7tsOft° 2016-Dec-07 08:33:02 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 11 RCCA ...s\scalLlangewonhy\Documents\York\Project2.wp Calc=MJ7 Front Doorfaces: N Calculation Procedures A, B, C, D Dar i Dale: Dec 05,2016 Entire House By: CERR®NE Plan: 59 devin Procedure A-Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 0.40 ach x 11040 fits x 0.0167 = 74 cfm 2. Winter infiltration load 1.1 x74 cfm x 74 OF Winter TD = 5991 Btuh 3. Winter infiltration HTM 5991 Btuh / 201 ft' Total window = 29.8 Btuh/ft' and door area Procedure B -Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.20 ach x 11040 ft3 x 0.0167 = 37 cfm 2. Summer infiltration load 1.1 x37 cfm x 13 OF Summer TD = 526 Btuh 3. Summer infiltration HTM 526 Btuh / 201 ft2 Total window = 2.6 Btuh/ft' and door area Procedure C - Latent Infiltration Gain 0.68 x33 gr/Ib moist.diff. x 37 cfm = 836 Btuh Procedure D - Equipment Sizing Loads 1. Sensible sizing load Sensible ventilation load 1.1 x 0 cfm vent. x 13 OF Summer TD = 0 Btuh Sensible load for structure(Line 19) + 36025 Btuh Vent + structure+ other equip loads = 36025 Btuh Rating and temperature swing multiplier x 0.90 Equipment sizing load- sensible = 32422 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 0 cfm vent. x 33 gr/Ib moist.diff. = 0 Btuh Internal loads = 230 Btuh x 36 people + 8280 Btuh Infiltration load from Procedure C + 836 Btuh Equipment sizing load- latent = 9116 Btuh *Construction quality: Best Fireplace construction: Best Number of fireplaces: 1 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 02 wri htsOft- 2016Deo-0708:age1 9 Right-Sude®UnNersal 201717.0.16 RSU25116 page 1 .ACCA ...s\scoff.lwgmorthy\Dm merdslYoAN mject2.rup Calc=MJ7 Front Door faces: N M Project Summary Dateo Ent re douse J By : Dec 0 , 201"0 CERRONE Plan: 59 devir-, 6iect Information For: CERRONE,A CERRONE QUEENSBURY, NY 12865 Notes: Desiqn Information— -- Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 70 OF Inside db 72 OF Design TO 74 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 33 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 99368 Btuh Structure 36025 Btuh Ducts 4968 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 104336 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 32422 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Best Fireplaces 1 (Best) Structure 9116 Btuh Dus CCentral vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftp 2780 2780 Equipment latent load 9116 Btuh Volume(W) 11040 11040 Air changes/hour 0.40 0.20 Equipment total load 41538 Btuh Equiv.AR (cfm) 74 37 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade AFFINITY Model TM9X120D20MP11 Cond CZF04814C AHRI ref 2008696 Coil FC48C3XC1+TM8V080C16MP11+S1-1TVM4N1 AHRI ref 5561866 Efficiency 95.5AFUE Efficiency 12.3 EER, 14 SEER Heating Input 120000 Btuh Sensible cooling 32550 Btuh Heating output 114000 Btuh Latent cooling 13950 Btuh Temperature rise 67 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.015 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft 2016-Dec-0706:33:02 9 Right-Suite®Universal 201717.0.16 RSU25116 Page 1 ...s\scott.langeworthy\Documents\York\Projecl2.mp Calc=MR Front Door faces: N Mght-J@ ryVorksheet JOb: Entire House Date: Dec 05,2016 By: CERRONE Plan: 59 dew MANUAL J:7th Ed. 1 Name of roan Entire House MASTER BEDROOM MASTER BATH WIC 2 Length of exposed wall 330.0 It 29.0 It 17.0 It 5.0 It 3 Room dimensions 12.0 x 17.0 It 6.0 x 11.0 It 5.0 x 11.0 It 4 Ceilings I Condit.Option 8.0 ftl d 8.0 ftl heat/cool 8.0 111 heat/ood 8.0 it heal/cool TWE OF CST HTM Arm Load(Btuh) Area Load(Bluh) Area Load(Btuh) Area Load(Bhfi) EXPOSURE NO. Htg I Clg (112) Htg I CIg (it) Htg Clg (III Htg Cig (ftp Htg Clg 5 Grass a 12MO 2.7 0.6 89 •••• TMTM 0 «TM •••• 0 •,« "" o -"» •••• Exposed b 12MO 27 0.6 W) •'« 106 "" •• 0 ••• 0 +•• """ walls and c 14AO 37.7 4.7 gm 163 153 "' 45 _ partitions d 15E0 6.4 0 1248 "" 0 "'" •" 0 ' "• 0 «• e 0 0 111111 "" •••• 111111 TM« IIIII! "•' 111111 ""^ `TM f 0 0 111111 »« "`• 111111 ••"" 111111 "" 111111 ""» `•• 6 Wlndvws and a 3D0 26.7 TM 73 1950 '•" 15 401 .... 0 0 ...: 0 0 "•• glass doors b 3D0 28.7 90 2393 "•' 15 401 '••• 0 0 .... 0 0 "•• Heating c 0 0 0 '•" 0 0 - 0 0 TMTM 0 0 "•• d 0 TM 0 0 TMTM 0 0 « D 0 0 0 TMTM e 0 0 0 0 0 0 0 0 0 f 0 0 0 ""• 0 0 0 0 0 0 7 Windows and North 17.6 73 •"' 1225 15 TM*' 264 0 - 0 0 ^ " 0 glass doors NE/NW 0 0 0 0 0 0 0 0 """ 0 Cooling E/W 828 30 1878 15 ""• 939 0 'TM 0 0 •""` 0 SE/SW 0 0 0 0 '^" 0 0 •" 0 0 ""« 0 South 30.6 60 "" 1823 0 """" 0 0 •`•' 0 0 ""^ 0 Hoz 0 0 ... 0 0 ""' 0 0 "' 0 0 "•• 0 8 Other does a 10D0 34.0 7.6 18 596 134 0 0 0 0 0 0 0 0 0 b 11BO 27.2 6.1 21 570 12B 0 0 0 0 0 0 0 0 0 C 0 0 0 0 D o 0 0 0 0 0 0 D 0 9 Net a12MO 27 0.8 72 196 44 0 0 0 0 0 0 0 0 0 exposed b 12MO 27 0.6 377 1032 232 93 255 57 0 0 0 0 0 0 wells and c 14AO 37.7 4.7 884 32623 4100 138 52DB 655 153 5774 726 45 1698 213 partitions d 16E0 6.4 0 1227 7898 0 0 0 0 0 0 0 0 0 0 e 0 0 mut 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 10 Ceilings a C pa 21.5 10.81400 30151 15075 0 0 0 0 0 0 0 0 0 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 111111 0 0 111111 00 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 19AO 11.5 0 1380 15931 0 204 2355 0 68 762 0 55 635 0 (Nate:room b 21AO 1.8 0 20 36 0 0 0 0 0 0 0 0 0 0 pelmetw c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 1s displ. d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 12 Irfiltratiorn t 29.8 26 201 5981 526 30 894 79 0 0 0 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 ••• 88388 - TM' 9513 - "' 6536 .... '•' 2333 Less external healing 0 "' 0 - 0 . 'TM 0 ••• Less transfer •" 0 0 " 0 TM• 0 Heating redistribution 0 _ '•• 0 •'" »" 0 _ "`• 0 14 Duct loss 5% 4868 - 5% 476 "" 5% 327 .... 5% 117 15 Total loss=13+14 104336 .... 9969 "" TM' 6863 .... "' 2460 ••" 16 hs.gains: People @ 300 36 ...• 10800 4 - 1200 4 •TM• 1200 4 '"" 1200 Appl. @ 1200 0 '•« 0 0 "" 0 0 •"` 0 0 "" 0 17 Subtot RSH gain=7+8..+12+16 «• 36025 »" '•"' 3193 "" "• 1926 •TM• "• 1413 Less external coding TM' 0 «« •••• 0 ••• 0 'TM •« 0 Less transfer « •• 0 «•• ••« 0 ••• 0 ••• 0 Cooling redistribution ••• 0 »» 0 « 0 - •» 0 18 Duct gain 0% •"• 0 0% •« 0 «0% "' 0 • 0% •» 0 19 Total RSH gain=(17+18)'PLF 1.00 '"' 36025 1.00 '"" 3193 1.001928 1.0D •'• 1413 20 Air required(cfm) 1550 1550 148 137 X102 83 36 81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrllghtts ft- 2016-Dec-0708:33:02 Right-SufteO Universal 2017 17.0.16 RSU25116 Page 1 . ...slseatl.langeworthylDocumentslYorklPmjmt2.mp Calc=MJ7 From Door faces: N Right-J®Worksheet JOC: Entire House !Date: Dar;05,2015 CERRONE Plan: 59 devin MANUAL J:7th Ed. 1 Name of noun ENTRY CLOSET BEDROOM BEDROOM2 2 Length of exposed wall 12.0 ft 5.0 ft 24.0 ft 20.0 ft 3 Room dimensions 8.0 x 6.0 It 4.0 x 5.0 It 120 x 120 It 10.0 x 10.0 It 4 Ceilings 1 Condit.Option 8.0 It I heat/ood 8.0 It heat/cool 8.0 It heal/oatl 8.0 It he:et/cod TYPE OF CST HTM Area Load(Btuh) Area two(Btuh) Area Load(Btuh) Area Load(Stuh) EXPOSURE NO. Hlg Clg (H� Htg Clg (ftp Htg Clg (ftp Ht9 CIg (ftT) Htg Clg 5 Gross a 12MO 27 0.6 24 "' "'• 40 •« 0 •• -,„ 0 •• ••• Exposed b 12MO 27 0.6 0 "' '"" 0 "*" « 108 "' 0 "« walls and c 14AO 37.7 4.7 72 »" 0 " 108 `« 180 « partitions d 15EO 6.4 0 0 « •»• 0 «*• 0 •„ 0 "» e 0 0 111111 « "" 111111 «" '• 111111 '•• !11!11 "« `• f 0 0 nun 6 Window and a 3D0 26.7 » 0 0 '""" 0 0 "" 15 401 •,"' 0 0 "•" 3 "•• glass doors b 3D0 26.7 » 0 0 '«" 0 0 "" 15 401 , 0 790 ••" Heating c 0 0 0 "` 0 0 "• 0 0 ••" 0 0 '« d o 0 0 0 0 " 0 0 0 0 ... e 0 0 0 „• 0 0 " 9 0 0 0 f o 0 0 «« 0 0 « o o «• 0 0 7 Window and North 17.6 0 «« 0 0 "" 0 15 - 264 0 " 0 glass doors NE/NW 0 0 «« 0 0 '•'" 0 0 •"'" 0 0 """• 0 Coding E/W 626 0 «" 0 0 «"` 0 15 ..,. 939 0 ""« 0 SE/SW 0 0 ••"` 0 0 « 0 0 ... 0 0 ""•• 0 South 30.6 0 •"" 0 0 «"' 0 0 `« 0 30 "« 905 Horz 0 0 "• 0 0 •'"' 0 0 "` 0 0 •" 0 8 Other doors 810D0 34.0 7.6 0 0 0 18 598 134 0 0 0 0 0 0 b 1180 27.2 6.1 0 0 0 0 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12MO 27 0.6 24 66 15 23 62 14 0 0 0 0 0 0 exposed b 1240 27 0.6 0 0 0 0 0 0 93 255 57 0 0 0 walls and c 14AO 37.7 4.7 72 2717 341 0 0 0 93 3510 441 150 5677 713 partitions d 16EO 6.4 0 0 0 0 0 0 0 0 0 0 0 0 0 e 0 0 111111 0 0 111111 00 111111 0 0 111111 0 0 r o o 111111 a o 111111 o 0 111111 0 0 111111 0 0 10 Ceilings aC pa 21.5 10.8 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 C 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 111111 0 0 111111 0 0 HIM 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floras a 19AO 11.5 0 48 554 0 20 231 0 144 1662 0 100 1154 0 (Note:rain b 21AO 1.8 0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 is dspl. d 0 0 111111 0 0 111111 0 o 11111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 12 Infiltration t 29.8 26 0 0 0 18 521 46 30 894 79 30 681 77 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 »» 3337 "••• ••« 1410 """" .... 7122 "`• `„• 8503 Less external heating •»• 0 „•• „„ 0 •••• »» 0 •••• „« 0 »,• Less transfer »» 0 «•• •••• 0 „•• ,«• 0 •„• •••• o »•• Healing redistribution 0 ,•» ••» 0 •'•• »» 0 •... `«• 0 •„• 14 Duct loss 5% 187 «" 5% 70 "" 5% 358 "'• 5% 425 15 Total loss=13+14 "" 3504 «« » 1480 "" 7478 """' 8928 16 IM.gains: People 300 4 ' 1200 4 '"`• 1200 4 - 1200 4 "" 1200 Appl. a 1200 0 "" 0 0 "'« 0 0 """" 0 0 "" 0 17 Sublet RSH ga1n=7+8..+12+16 .... «^ 1556 """ «« 1393 ••« „•. 2980 •••• •••• 2898 Less external cooling 0 „„ o "'« »„ 0 „ » 0 Less transfer .". „. 0 •••• „„ o •„ •• o ,„ « 0 Coding redistribution '•"" '«• 0 •••• «„ 0 '•„ «», 0 •,•• '•"• 0 18 Duct gain 0% "• 0 0% "« 0 0% •" 0 0% '« o 19 Total RSH gain=(17+18)`PLF 100 1556 1.00 ««. 1383 1.00 ••" 2980 1.00 "• 2896 20 Air required(cfm) ... 52 67 22 60 111 128 133 125 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. A -pp- wrightsoftl 2016-Dec-0708:33:02 RghFork%P Universal 2017 77.0.18 R rent D 8 Page 2 ...slscdt.lengewMhy\Documents\YcrklPm)eot2.rup Calc=MJ7 Fmnt Daor faces: N Right-A)Worksheet job: Entre House Date: Dec 05,2012 CERRONE Plan: 59 deli, MANUAL J:7th Ed. 1 Named mom BATH KITCHEWGR BASEMENT 2 Length of exposed wall 6.0 It 58.0 It 156.0 ft 3 Room dimesiors 9.0 x 6.0 ft 1.0 x 689.0 ft 50.0 x 28.0 ft 4 Ceilings Condit,Option 8.0 ft heaNccd 8.0 ft heattood 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(stun) Area Load(Btuh) Area EXPOSURE NO. Htg CIg (ft2) Hig Clg (ft=) Hlg Clg (ft') Htg cig Hig Clg 5 Gross a 12MO 27 0.6 0 ••• 25 «• «• 0 » •, ,•• •• Exposed b 12MO 27 0.6 0 TM 234 «.. «. 0 « ,.,. walls and c 14AO 37.7 4.7 54 189 » ••• o •• »• partitions d 15E0 6.4 0 0 "' "" 0 «• 1248 •• •,• •» e 0 0 111111 "' «•' 111111 »« •' !!1111 "' •` •« •^ f 0 0 111111 «'" "•"" 111111 '•« TM'" I!!I!! "•• "•' •�•• •«• 6 Wirxlays and a 3D0 26.7 •' 0 0 •'•' 43 1149 """ 0 0 •••• TM» glass doors b 3D0 26.7 '• 0 0 'TM• 30 801 ,,•• 0 0 •••• «•• Healing c 0 " 0 0 '»• 0 0 ""• 0 0 "" TM• e 0 0 0 ^« 0 0 0 0 «• r o 0 0 '^ 0 0 0 0 7 Window and North 17.6 0 •^` 0 43 ••• 757 0 »" 0 ^`• glass cl o NE/NW 0 0 ^' 0 0 `•' 0 0 "' 0 Coding E/W 62.8 0 •" 0 0 "" 0 0 ••" 0 "• SE/SW 0 0 •• 0 0 « • 0 0 ••• 0 ^•• South 30,6 0 ^• 0 30 ••« 918 0 ••• 0 ••• Horz 0 0 0 0 •••• 0 0 "' 0 "• e Other doors a 10D0 34.0 7.6 0 0 0 0 0 0 0 0 0 b 1180 27.2 6.1 0 0 0 0 0 0 21 570 128 C 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12MO 27 0.6 0 0 0 25 68 15 0 0 0 exposed b 12MO 2.7 0.6 0 0 0 191 523 117 0 0 0 walls and c 14A0 37.7 4.7 54 2038 256 169 BW1 754 0 0 0 partitions tl 15EO 6.4 0 0 0 0 0 0 0 1227 7899 0 e 0 0 Hill 0 0 111111 0 0 11111! 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 10 Callings a C pa 21.5 10,8 0 0 0 0 0 0 1400 30151 15075 b 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 Iglu 0 0 111111 0 0 d 0 0 m111 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 1111, 0 0 f 0 0 111111 0 0 11!!!! 0 0 111111 0 0 11 Floors a 1940 11.5 0 54 623 0 689 7954 0 0 0 0 (Note:room b 21AO 1.8 0 0 0 0 0 0 0 20 36 0 perimeter c 0 0 111111 0 0 111111 0 0 1111" 0 0 is disp. d 0 0 Mill 0 o mut 0 0 111111 0 0 fm slab e 0 0 11m1 0 0 !11111 0 0 111111 0 0 floors) f 0 0 111111 0 0 IIII!I 0 0 111111 0 0 12 Infiltration t 29.8 26 0 0 0 73 2175 191 21 626 55 Ventilation 0 0 0 0 0 0 13 Subtotal 1oss=6+8.+11+12 •" 2881 - ••' 18871 "" 39282 ^« Less external heating ••• 0 ,„• 0 « 0 Less baMefer ^• 0 ,.„ 0 0 ' Heating redistribution 0 ••« _ 0 _ 0 14 Duct loss 5% 133 »•• 5% 934 « 5% 1984 '^ 15 Total loss=13+14 »• 2794 "" ••• 19605 « `» 41246 «' 16 IM.gains: People @ 300 4 '»' 1200 4 «• 1200 0 ""« 0 '« Appl. @ 1200 0 0 0 '•« 0 0 0 ••• 17 Sublet RSH gain=7+8..+12.16 «• 1458 «„ `•« 3953 "" "' 15258 '•'• •« Less external coding „• " 0 ••» 0 ••• 0 •« Less transfer «• 0 0 ••• 0 •« Cools g redistribution ••• 0 0 0 •« 18 Duct gain 0% 0 D% ' 0 0% 0 `^ 19 Total RSH gain=(17+18)•PLF 1 ....00 • 1456 1.00 « 3953 1.00 •' 15258 «• 20 Air required(cfm) 42 63 291 170 „ 613 657 Calculations approved by ACCA to meet all requirements of Manual J"7th Ed. * Wright �Tt' Right-Sulle®Unlversa1207717.0.16 RSU25116 2016-Dec-07 08:33:02Page 3 ...s\scott.lengmorthy\Documents\York\Pmject2.mp Calc-MJ7 Front Doorfaces: N Window Data job: Date: Dec 05, 2016 By: C E R RO N E Plan: 59 devi n W S O G L S S N I S O O W C W S N K R L O T H G N H V V H H N H D Y I A W R A L C C R R G T A A W Z E M D Z L O X Y T M R R MASTER BEDROOM 3D0 n n e y n n 2 90.0 1.0 0.0 0.0 5.0 17.6 15.0 0.0 3D0 n w e y n n 2 90.0 1.0 0.0 0.0 5.0 62.6 15.0 0.0 BEDROOM 3 3D0 n n e y n n 2 90.0 1.0 0.0 0.0 5.0 17.6 15.0 0.0 3D0 n e e y n n 2 90.0 1.0 0.0 0.0 5.0 62.6 15.0 0.0 BEDROOM 2 3D0 n S e y n n 2 90.0 1.0 0.0 0.0 5.0 30.6 29.6 0.0 KITCHEN/OR 3D0 n n e y n n 2 90.0 1.0 0.0 0.0 5.0 17.6 43.0 0.0 3D0 n S e y n n 2 90.0 1.0 0.0 0.0 5.0 30.6 30.0 0.0 wri htsoft° 2016-Dec-07 06:age 1 9 Rlght-Suite®Universal 2017 17.0.16 RSU25116 Page 1 AC0, ...s\scotl.langewonhy\Documents\York\Prcjecl2.rup Cale=MJ7 Front Door faces: N GRAJNY onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 06/20/2017 Cerrone Construction LLC 51 Oak Valley Way Queensbury,NY 12804 Inspection Address: 25 Devin Court, Queensbury NY 12804 Report Number: 0620175 Dear Steven: The Blower Door Test to verify infiltration rate of the subject property was performed on 06/20/2017. This was done to verify mandatory requirements of 2015 IECC Code as amended by the NYS Uniform Code Supplement. This report does not imply that full compliance of above codes has been met.It's verified the infiltration rates only. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the house, including conditioned basement=2,800 SF - Volume of the house, including conditioned basement=23,800 CF Based on above,the following test data was collected: - Infiltration Rate, including conditioned basement at 50 Pascal=729 CFM - ACH50,Actual Changes per Hour at 50 Pascal=729X60/23,800=1.8<3 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 JM Climate Pro® Fiber Class Blowing Wool Your home has been professionally insulated to provide superior thermal resistance. J .� r Homeowner's Name i Date - Address cityI t 17 \k l ' State /1 r zip RECORD OF INSTALLATION / BlUVVIND 1NDUL RATES AND RULLS Nck CaflttnfL'don If RBtroSt' 8-VALUE THICKNESS AREAINSULATED age,brofit Depth of Previous Insulation h,. Ceilings sq.1t Number of trip used %j3 EstimatedR-veYWaofPreviousdnstallation m. sq.1l. � Walls so.h. Area Insulated k ' n ted 1[` " . Types of Previous Insulation in Anic sq. Thickness of B15ulation h. r, f Floors :n s4 it. R•value of Insulation - _ .� _, uf. sq.it, CLIMATE PRO INSULATION, RAG WEIGfIT-31.5 LB.NOMINAL R.VALUE 'IEf1U�lUNC9NSfAL,6'ED SEfTLEG'iNICKNE33(MJ RAGS PERUMSD.PL ffjtANIUMNET M1INMUNVYEIDRT (%mgjLeFBTU) TKICkAESSlie.).. CDVERADE{sgft.76a91. (WeJaq.t41 To obtain an insulation Installed insulation Expected thickness Minimum number Contents of this bag The weight per sq.ft resistance(RI of should not be less after long-[arm settling begs per 7,800 sq.ft. should not cover of installed insulation [hen: has occured of net area: more than: should not be less than: tl Al 4.3 4.B 209 0.150 13 5.0 5.0 5.7 76 0.179 19 7.2 i.2 BA 118 0.266 22 8.3 8.3 9.9 101 0.310 25 9.7 9.7 11.8 85 0.311 30 11.1 111 73.7 73 0.432 38 13.8 13.8 17.7 56 0.559 44 157 75.7 1 48 0 49 �,-' 17.3 / 17.3 23.5 43 Die 60 7 207 29.5 34 8 Sae rawrse fac&lamune aEoa ��n ��a�Pm�atr�,.;�[a,�dla�n/l. h[srlation Contractor Signature \y Data Company Collins & CO. ss Interstate Ave.Albany, NY 12205 Phone(518)456-1297 Home Builder Signature Data Company Address Phone J� Johns Manville Pornaxa intsrniativa.can 7.80085a4I0.9 snc-m 5m D 2623 Johns Manville.71717th street,Denver.0080202 Map Reference: \ The Village at Sweet Road Map of a Subdivision plan made for l Cerrone Builders Dated: February 5, 2014 / jz Last Revised: July 30, 2014 / RIP-RAP By: Van. Dusen & Steves l l I . Filed: September 30, 2014 RIP '38 � RIP-RAP _ 133.50, I _ ` ...P...t:::.. Lands of d` l a f The Vfflacje at Sweet Road HOA - a4 N The �a e � n 0 V d / 1 o r �1 C° / Story - _ - — age a of O N t o O - S _ W r. - e r r e 1\ l 2 m e - R 0 / [IOU, - - a u t d � o e tIOA - -o W / a - 1 kln - 33. 9 / : _ . ..:.::::...........:: ......:....:....... . / _ -Area - - - ----- - — - _ -- - - - - 0.30 Acres 13252.1 S Feet ' _ a , 138.80 ! N 84'14102" W talc aoX - Cabie TV ]j NOTES: BENEFI T r EWk ANTS, RESTRICTIONS INCLUDING FROM RIGHTS, EASEMENTS, 1. JARCEL BE SUBJECT TO AND/OR MOVEN 1 1: AN EASEMENT GRANTED To NIAGARA MOHAWK POWER CORPORATION & VERIZON NEW YORK INC. RECORDED IN THE WARREN COUNTY CLERK'S . : IAL S OFFICE IN BOOK 5120 OF DEEDS, AT PAGE 10 } � 1.2.= DECLARATION OF COVENANTS, RESTRICTIONS, EASEMENTS AND. LIENS OF " ---_ -- THE VILLAGE AT SWEET ROAD HOMEOWNERS' ASSOCIATION INC. ,`.,s: RECORDED IN THE WARREN COUNTY CLERKS OFFICE IN BOOK 5175 OF So 13") DEEDS, AT PAGE 148. 0 L Abp S 1.3: RIGHT-OF-WAY AND. EASEMENT TO THE TOWN OF QUEENSBURY FOR SEWER � RECORDED IN THE WARREN COUNTY CLERK'S OFFICE IN BOOK 5157 OF DEEDS, AT PAGE 248. :Datel une 2 f Dus 'UNAUTHORIZE9 ALTERATION OR ADDITION TO A SURVEY _ �( y] $' �r �7 (� j' -Scale 1"=20r ' MAP BEARING A ULENSED LAND SURVEYORS SEAL IS A Map of a Serve ma`ve So� _ i VN OF SE(;{ION SUB-DIVISION 2,OF THE NEW YORK YOYORK STATE EDUCATIOATIO N LAW.' Ste -ves 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY - - - MARKED WH}I AP{ORIGINAL CF THE LAND SURVEYORS SEAL SHALL BE 60NSIDERED TO BE VALID TRUE COPIES.- ���''''y+yt 'CERTIFICATION]INDICATED HEREON SIGNIFY THAT THIS SURVEY WA,'PREPARED IN ACCORDANCE WITH THE _ - errone Builders EXISTING CODE 9F PRACTICE FOR LAND SURVEYORS ADOPTEDBY THE NEW YO �TT _ LAND SURVEYORS S IDT CERTIFICATIONS SHALL RUN(ONAL ONLY i TO THE PERSON{FGR WHOM THE SURVEY IS PREPARED,AND = - SHEET i OF 9 ON HIS BEHALF j0 THE TITLE COMPANY,GOVERNMENTAL �t .y g� /'� T�� 'q/ ' ' 'g, �7 e� 9 ry AGENCY AND LE!5NG INSTITUITTON LISTED HEREON,AND Town of Queen bury, Warren Bounty, New fork 169 Haviland Road Queensbury, New York 1(2804 � TO THE ASSIGNEE."OF THE LENDING INSTITUTION." CfKRONE BUILDERS (518) 792 -6474 New York Lic. No. 50135 NO DATE DESCRIPTION . - - of DWG NO 052�7 i