Loading...
SEP-000716-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SEP-000716-2016 Date Issued: Thursday, October 20, 2016 This is to certify that work requested to be done as shown by Permit Number SEP-000716-2016 has been completed. Tax Map Number: 309.9-2-1 Location: 200 LUZERNE RD Owner: Homestead Village Applicant: Homestead Village This structure may be occupied as a: Residential Septic Alteration By Order of Town Board TOWN OF QUEENNSSBU/RfY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, (i(,i(iMVV///Kxx V Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SEP-000716-2016 Tax Map No: 309.9-2-1 Permission is hereby granted to: Sanitary Sewer Service For property located at: 200 LUZERNE RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Homestead Village Septic Disposal-Residential 50.00 Owner Address: 200 Luzeme RD Total Value S0 00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Sanitary Sewer Service PO Box 224 Glens Falls,NY 12801 Plans&Specifications Residential Septic Alteration 540.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,October 17,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the exp.ration date.) Dated at the Town of ueensb (I�Vjr(( /1 on a er 17,2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement SEPTIC DISPOSAL PERMIT Office Use ONv Received Tax Map ID aAKWAPPermit No. cne -41 2R 1�,Q Yl/ PetFe LWAVOROF!IN3PddA4BN Appm >, v APPLIVAANT 1,11n e_rT('-u `�.//-Gi U PNONE/E-MAR ADDRESS Cu 11r'i c/ I.... 74- 1NSYAUAMW RB@R: PHONE/E-MAIL /� j{c ,�) 6,: /l=,, PHONEIE•MA1L Address 1 Cd d re s-PERSON FOR RUIL9ING ru' 4201PeS COMPLIAI=. �0�:.% e 6� _'`e/" 1 PY.ONE �J�7e ej f��,gIBEN@@ IN€Bt?Md59DN Year Built $oTbedloomis nGailonsperbedloom =Total Daily Flow 1980 or older /GL }c Z• Garbagegimdarinstalied _Y -N 1961-1991 Spa orriotTubinstalled _Y LN 1992-Present PaRGEL INFQA&I9T1QN - Topography _Mat roiling _.Steep slope _%slops SO Nature Sand _Loam _clay _011W Groundwater At What dapth2 .N Badrook I impervioue Material At what depth4 i r DOMNtic Water Supply YMunicipal _Well(if wall,water supply from any sepWsystemabsorption is_ft) Percolation Test Rate: /- 3 per minute par inch(4estto be completed by licensed engmeering 1 archilect) Rn USED SYS-EM FOR AIAM CON33UL"riON Tank Size /Cgallons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hottub) System Type Absorption field wnh d2 stone Total length ,-W ft:Each trench x} Seepage Pit VMfps stone How many- size Alt®mattveSystem Bedorother We? Holding Tank System Total isq&adcapacity? Tank slze =oftanits Notes• 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Suitt plan is received&approved The installed system must match the septic system layout on Ills-no exceptions. DEMLARAeZON: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. i have read the regulations and agree to abide by ese and all re iremaMs of the Town of Queensbury Sanitary Sewage Disposal ordinance. Print Names l�J Date: Signature: � z Date: Town of Queensbury Building&Codes Septic Disposal Permit dilly 2014 ' o IIIIIIIIIIII� ��Illlllllllll ENVIRONMENTAL DESIGN c i EP -nCIIJZ 1 to-7-n 1 l0 PARTNERSHIP,LLP Octoberf 19, 2016 Queensbury Building & Code Enforcement 742 Bay Road Queensbury,NY 12804 AS Fl. 1.11 . Via email john@queensbury.net Attn: John O'Brien Re: Homestead Village Mobile Home Park Lot 163 Elmhurst Dear John: On October 18, 2016 our office inspected the above referenced Homestead Village Mobile Home Park lot. The purpose of this visit was to observe the installation of the new septic system designed by EDP. Based on my review of the plans and observation of the installation it is my opinion that the system was installed substantially in compliance with the intent of the design plans. I have attached a copy of the as-built plan showing three lines at 50 ft each. Please contact me should you have any questions regarding this system. Sincerely, James E. Mitchell, P.E. cc:NYSDOH Michael Hallock, P.E. 900 Route 146, Clifton Park, New York 12065 phone(518)371-7621 -fax(518)371-9540 BORING AND PERCOLATION TEST: �� ooesuw iwr�i�iw°�crvu Rin rAJAI PC50u°�s'W° - ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR'MOTTUNG - PERCOLATION RATE APPROXIMATELY ONE MINUTE a .Os: s cov I�g ro 9E L9N0 D eY 9.[ P -a 10 9AL IL90 s1re. 2 a e E -/ SEPTIC DESIGN: L� APPLICATION FATE - 1.2 GAL/SF/DAY 3 BEDROOMS AT 100 GALLONS/BEDROOM X300 GALLONS USE 3 LINES AT 42 FT. EACH (SPACED 6 FT. ON—CENTER) aw INSPECTION REQUIREMENTS: e ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING. 2 +s-euu.°oismrewm eox n AS T {{ LOT 164 ? � q LOT 183 , LOT 162 fkgS' 9�•` 9 �u i NELMHURST$I g AVENUE i 114 AS-BUILT SEPTIC REHABILITATION ' PREPARED FOR LOT 163 ELMHURST DRIVE HOMESTEAD VILLAGE TOWN OF OUEENSBURY WARREN COUNTY, NEW YORK SCALE: i" — 20' OCTOBER 18, 2016 N TE, t EN IROTE 146 CLIFTON PAIGN PAR 065 R 8)3, LLP 7621 ± y MOBLLE HOME UNITS TO BE PLACED VATH A MINIMUM 10 FT. HORIZONTAL SEPARATION, ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. U'L ELL P.E. E3.337 r s .. NOTE: ' , BORING AND PERCOLATION TEST: . y) BASEDOES NOT INFORMATION OBTAINED FROM PUBTRUM Y AVAILABLE RESOURCES AND I ASSUMED CONDITION BASED ON SITE EVALUATION DOES NOT REPRESENT AN ACTUAL FIELD INSTRUMENT SURVEY. `} i 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING PERCOLATION RATE APPROXIMATELY ONE MINUTE d I NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. Z N 0 R r y SEPTIC DESIGN: APPLICATION RATE = 1 .2 GAL./SF/DAY 3 BEDROOMS AT 100 GALLONS/BEDROOM } =300 GALLONS USE 3 LINES AT 42 FT. EACH (SPACED 6 FT. ON—CENTER) _ EXISTING 1000 GALLON SEPTIC TANK (TO REMAIN) WOODS a WOODS ti Q —. rn _ h EX INSPECTION REQUIREMENTS: 00. SHED 0 SHED t. ENGINEER OF RECORD TO INSPECT N TRENCHES PRIOR TO BACKFILLING. 0 EX 30 SHED 0 N V O PROPOSED DISTRIBUTION BOX #1 I (SEE DETAIL - SHEET 2) I _ Z HOME til : J I i I o OPYEXISTING I I i °� `� U MOBILE Ir HOME i i I W I m W I I M I I i TOWN OF QUEM EXISTING lJ -°� \ W REPLACE EXISTING LEACH FIELD W/ -I- L i MOBILEBUILDING & 309.9-2-1 SEP_000716_2016 PROPOSED ABSORPTION FIELD �® - `�- -! Homestead Village 3 LINES AT 42 FT. EA. Reviewed �y° -�" (SEE DETAIL - SHEET 2) �_ J Date: ._ --� -- 163 Elmhurst 'I o LOT 164 I i Residential Septic Alteration W I�OT 163 LOT- 162 _ T PARKING PARKING PARKING SEPTIC PLOT PLAN W AREA AREA i I + FENCE I AREA I 1� l_ I HAVE SEEN OR OBSERVED ALL OBJECTS SUCH AS HOUSES, WELLS, TREES, FENCES, ETC :� SHOWN ON THIS DOCUMENT.I HAVE PERSONALLY z GRAVEL GRAVEL D/RT I+._7`:1:s"i f s ,'v',;": ,i' n a W W.S. W S. ;"; " MEP 4�RED THE DISTA",'E SEr E RTN ON THIS DIAGRAM, W o W.S. SIGNATURE DATE S oI S e 3 W;ELMHURS T '; ._..,, AVENUE ;W 31 31 �W� 3 I 2 �z SHEET 1 OF 2 w SEPTIC DESIGN PREPA RED FOR 3 �z LOT 163 EDRIVE o � ,T.� HOMESTEAD VILLAGE " TOWN OF QUEENSBURY;$ WARREN COUNTY, NEW YORK ff b SCALE. 1 = 20f SEPTEMBER 15, 2016 NOTE: ENVIRONMENTAL DESIGN PARTNERSHIP, LLP a 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371 -7621 MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING \ - JAMES E. MITCHELL P.E. 53,337 J 4 CONSTRUCTION NOTES• 1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE TOPSOIL FOR SETTLING MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY =IIII=I IIII=IIII =IIII=IIII= -II�i—IIII— MUST BE PRESENT FOR A RIBBON TO BE FORMED. -IIII—IIII- —IIII= =IIII=IIII I I IIIII=III 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE —IIII— TERRATEX O 2 NONWOVEN EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS _I, I EARTH -IIII —IIII- EARTH IIII— CONSTRUCTION FABRIC OR O -IIII=I BACKFILL UNTREATED BUILDING PAPER BACKFILL Z REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE I=IIII OR STRAW NATURALLY FOR A PER/OD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW III=IIII= CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE Q DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY -IIII= =IIII= =IIII=I =IIII= REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE TOP OF AGGREGATE 4" PVC MIN. TO BE WITHIN O� �� OO �� MISALIGNMENT/BREAKAGE. 6"-12" OF SURFACE 2 RAKE ANY c PERFORATION JOINT 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS U � SMEARED n SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO TRENCH l� n n DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. O C/ WALLS O 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF ,7 r0 _� �� Z7 O� THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO ASSURE THAT EACH IS PRACTICALLY LEVEL. TRENCH BOTTOMS AND SIDEWALLS SHOULD BE CRUSHED STONE OR IMMEDIATELY RAKED AFTER FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN GROUNDWATER BEDROCK WASHED GRAVEL THE TRENCHES. /OR IMPERVIOUS LAYER 3/4" TO 1Y2" 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY INSTALLED AT A SLOPE OF %6 TO %32 /NCH PER FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE CROSS SECTIONAL VIEW LONGITUDINAL VIEW DETERMINED BY AN ENGINEER'S LEVEL, TRANSIT OR CARPENTER'S LEVEL. AN EASY METHOD OF MEASURING THE %6 INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A %4 /NCH BLOCK TO ONE END OF A STRAIGHT FOUR FOOT BOARD. BY PLACING THE BLOCKED END WITH THE BLOCK FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC USED TO DETERMINE THE %6 INCH PER FOOT SLOPE. A %8 /NCH BLOCK SIMILARLY USED WOULD NTREATED BUILDING PAPER OR PERMEABLE RESULT IN A %32 /NCH PER FOOT SLOPE. ANOTHER METHOD USED TO ESTABLISH THE GRADE OF GEOTEXTILE OR 4" LAYER OF STRAW i DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL BE INSTALLED IN THE TRENCHES TO I I I I I I I II — I I i III I—IIII— III- AGDEPTH GREGATOEFAT LEAST TWO MAY BE REQUIRED CTOE BRINGVTHEHE TOP OF TOP OF THEHAGGREG DISTRIBUTOR EO Wl H/N SIX DTOONL 12AIM111—NCHES IIII '--[III=)I OF FINAL GRADE. 2O O — - =IIII=67 6767 I - II IJ 6) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING O � 01-2 oD � PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON _THE AGGREGATE AND THE TREIVCH FLOW PROVIDE CAPS BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE 0 0 0 0 0 0 0 0 0 0 0 0 c c 0 0 yo 0 0 0 0 0 0 0 0 0 0 0 o ON LINE ENDSTRENCHE BUILDINGSPAPERL�O PRE ENT SDEWALBE TEMPORARILY L COLLAPSE AND SIWITH AN LTATION INTOERVIOUS THEAGGREGATE.ERIAL, SUCH AS TRE/>(ED O� OO OO OOnOO OO ' 7 THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THE ORIGINAL GROUND LEVEL (I.E., PIPE Xe"—)S2" PER FT., NOT rn COMPACTED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENTSPACING OF ABSORPTION TRENCH 6' O.C. THE ENTIRE AREA SHOULD BE TRENCH BOTTOM TO BE NEAR 30 GRADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT LEVEL AND RAKED SHALL NOT ENTER THE ABSORPTION FACILITY AREA OR THE PROPOSED EXPANSION AREA AFTER THE TRENCH PROFILE ° SUBSURFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED. N wl 8) A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND ANY WATERLINE. WHERE LINES MUST CROSS, THE WATER SERVICE LINE SHALL BE AT LEAST 12 ABSORPTION TRENCH DETAIL INCHES ABOVE THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE VERTICAL SEPARATION MUST BE AT LEAST 18 INCHES. I x 9) ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE NOT TO O___SCALE SYSTEM. WATER SOFTENER, WATER RECHARGE AND BACKWASH WASTES NORMALLY ARE NOT TO BE - „ DISCHARGED TO=:TIIE-SYSTEM.UNLESS:A SEPARATE-SUBSURFACE DISCHARGEv TO_F>N..Af?EA 25Q, FEET, FROM.,WELLS OR WATER COURSES -IS UNAVAILABLE ' '-` - o . J • ZI e { a UI ti , W 1 O ti J 2 W e S;^St i GRADE I o x NO TE: z I. PIPE JOINTS TO BE SEALED WITH i w ASPHALTIC MATERIALS OR EQUIVALENT. z 12" MIN, REMOVABLE CO VER 2. INVERT ELEVATIONS OF ALL w OUTLET PIPES MUST BE EQUAL. j J. THE SLOPE OF OUTLET PIPES s BETWEEN THE DISTP18UTION BOX 9 w AND THE DISTRIBUTOR LATERALS o .a BAFFLE SHOULD BE I/8" PER FOOT. w INVERT j INLET _ 2"MIN ELEV. Y J O O U FL E T CONTRACTOR TO USE SPEED LEVELERS z AS SUPPLIED BY FORT MILLER TO EQUALIZE FLOW. SHEET 2 OF 2 SfoANI TARP DETAILS FOR 12" MIN CLEAN SAND OR PEA 6RAVEL41 LOT 163 EDRIVE o mT . . HOMESTEAD VILLAGE ttt `:tr. TO WN OF QUEENSBUR Y WARREN COUNTY NEW �2 DISTRIBUTION BOX � �.� ,�� � YORK NOT TO SCALE SCALE: 1 " = 20' SEPTEMBER 15, 2016 vz 1r . ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371 -7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P.E. 53,337 J