Loading...
RC-000106-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000106-2017 Date Issued: Friday, August 25, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000106-2017 has been completed. Tax Map Number: 266.3-1-73.5 Location: 16 RIDGEWOOD CT Owner: PATTEN PROPERTY DEVELOPMENT,LLC Applicant: Chris Patten This structure may be occupied as a:2585 s.f. SFD w/2-car 484 sf garage 1 Gas Fireplace By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. , _ TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000106-2017 Tax Map No: 266.3-1-73.5 Permission is hereby granted to: PATTEN PROPERTY DEVELOPMENT,LLC For property located at: 16 RIDGEWOOD CT In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: PATTEN PROPERTY DEVELOPMENT,' Single Family-New $300,000.00 Owner Address: 20 Ridgewood CT Total Value $300,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency PATTEN PROPERTY DEVELOPMENT,LLC 20 Ridgewood CT Queensbury,NY 12804 Plans&Specifications 2585 s.f.SFD w/2-car 484 sf garage 1 Gas Fireplace $1,489.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,March 29,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eens �"edn y arch 29,2017 SIGNED BY: �QJ for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only Permit#:__1'ZG —Q 00 16U - I PRINCIPLE STRUCTURE PERMIT APPLICATION Permit Fee: $ t 3 11 (Q© L)kc ),,.I isbu r n 742 Bay Road,Queensbury,NY 12804 *Ret Fee:$ P:518-761-8256 www.gueensbury.net Invoice#: Project Location: f l0 �IOCi-�Lt�9fk� Tax Map ID #: pCo.�—� ,s Subdivision Name: *TOWN BD. RESOLUTION 86-2013: $850 recreation fee for new dwelling units: single family,duplexes/two-family, multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile homes. This Is In addition to the permit fee(s). CONTACT INFORMATION: • Applicant: Name(s): Mailing Address, C/S/Z: 2_0 R�a�-c,mss, Co,•r} Cell Phone: Land Line: �)Email:,'IA.'I'k sst1 @ vvtwi I -c o • Primary Owner(s): Name(s): ?a+-e+e,,t ���-v�•¢- , GL Mailing Address, C/S/Z: 2v2�J�� •� ��✓� �Y _ _ Cell Phone: Land Line: Email: S�v> • Contractor(s): Business Name: PA-jq,,_ &aL, fir. ALL Contact Name(s): C14,i5 o_4m Mailing Address, C/S/Z: Zo Po­-- Cell Phone: trw ) Land Line: E-t ) Email: . • Architects En ineer s Business Name: k l I (i-n ro E t �j /11 — of L_-e' er/1 Contact Name(s): T).,N rnh Il'_.'ti_y -- Mailing Address, C/S/Z: C'(e.s /!f /may Cell Phone: Land Line: Email: Contact Person for Building & Code Compliance: C !^r 1 S il/n w � Cell Phone:�_) Land Line: Email: Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial Residential WORK CLASS: Single-Family Two-Family _Multi-Family (#of units ) _Townhouse Business Office _ Retail W _ Hotel/Motel _Industrial/Warehouse Garage (#of cars�) _Other (describe ) SQUARE FOOTAGE: C,-u raj t 5- 1 st floor: _ 2n1 floor: (poZ ao� - 'floor: 3/[ Ll$`'1 sr- 4111 r- 4111 floor: Total square feet: 26_Q5 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 3 'r 2. Proposed use of the building: 'S"Do 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): Oilro-�� Solar Other Fireplaces need a separate Fuel Burning Appliances &Chimney Application, one per appliance 5. Are there any structures not shown on the plot plan? YES ��Explain: 6. Are there any easements on the property? YES A 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? ��i��Ze` — I , os,Qcrr b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES d. What is the water source? PUBLIC PRIVATE LL e. Is the parcel on SEWER or <EEATE SEPTIC ystem. Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 r DECLARATION: 1. 1 acknowledge that no construction shall commence prior to issuance of a valid b u i I d i n g permit and work will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: LV,t) �' W_kh SIGNATURE: 04 DATE: 337/1/ "7 Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 FUEL BURNING APPLIANCE & Office Use Only CHIMNEY APPLICATION Permit#: Permit Fee:$ firxYl %(�trcrna>ut.r 742 Bay Road,Queensbury, NY 12804 Invoice:#: P: 518-761-8256 www.gueensbury.net Project Location: g& f 16 N t(�ew&o-d C� Tax Map ID #: -1-73, s Room of Install: Gr- Fe- v Planned Install Date: **ONE APPLICATION PER APPLIANCE** CONTACT INFORMATION: • Applicant: Mailing Address C/S/Z• Z° ?,JV­v-X Cell Phone:_ - - zi&Sy _ — Land Line: ( ) Email: Pte- -�Fy eD 9✓ �-✓1 < « • Primary Owner (s): Name(s): ti t1'en Pa" t4-d -- Mailing Address, C/S/Z: ?w A t)5" .••�--� Cell Phone:_( -7 f 6 4/62 Land Line: _( ) Email: � o d''"`- Installer/Builder: Business Name: Pew Contact Name(s): Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: Contact Person for Buildin & Code Compliance: Cell Phone: (5 1�- ) 16114 tss y Land Line: _( Email: 0,1 j { , cum. —� Fuel Burning Appliance&Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: —Stove ` Fireplace Insert fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) Fireplace, factory built** **Manufacturer's name: /'� � Jie Model #: ��0007– v SOURCE OF HEAT: Wood Coal Pellet Das CHIMNEY INFORMATION: Masonry: block brick stone Flue: cc tie steel D __ size, in inches Material*: P`�' double-wall `triple-wall_insulated (*Manufacturer's name: � � Model #: ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four (24) hour notification is required for inspections. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and ag ree to the above: PRINT NAME: IS SIGNATURE: aL ZA_ DATE: 3 7 P Fuel Burning Appliance &Chimney Application Revised March 2017 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 P•518.761-8256 Permit#: • www.queensbury.net Tax Ma ID#: , Permit Fee: $ Invoice#: Map 2�0� 7--1 --7 3 s Project Location: IG Cvuy+ Septic Variance? Yes No Primary Owner(s) � -P,w ( Mailing Address �✓}— Phone & Email Installer/Builder Mailing Address c>H, Phone & Email Engineer aC� � Mailing Address u u �►► Phone & Email Contact Person for Building&Code Compliance: r+- G-�f e ex Phone: RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes o 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes o Installed? (circle one) 1992-Present �' PARCEL INFORMATION: - Topography Flat Rolling Steep Slope 916 Slope Soil Nature X Sand Loam Clay Other Groundwater At what depth? SVA 41 Z' Bedrock/Impervious material At what depth? I2' - Domestic Water Supply —Municipal )�Well(if well,water supply from any septic system absorption iizic`ft.) Percolation Test Rate: jz'per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size I LZ fo gallons(min.size 1,000 gallons,add 2S0 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length -2 CO ft.; Each Trench ° ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? 12CD ;tank size /ZS- ;#of tanks / NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: to V� I' IS I�aW' '� DATE: Z/ SIGNATURE: C/ �GG DATE: I ZIl Town of Queensbury Building&Code Enforcement Revised February 2017 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL PLC- l®b-20 1,-+ Permit No........... .....................y...�..Cert.N O 4 4 9 5 4 Cut-in Card No..................................... Owner.............. !..... .l..l.... tU'................................................................... ......... .............. Location.....1.......... .162G��� . P13.. '7i............................................ �................ ......... Installation Consisting of. s /..rf / $1 „�p !f'. t ..................................................................................................... .................................................................................................................................................................................... InstalledBy........Y�m.t—�..�...........................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making ' ections at any time, and if its rules are violated,the Company shall have the right to re�oe this rtifi ate. Date..... '. 7.. �Z.......... INSPECTOR...... .. ..... .............................. Member N.F.P.A..I.A.E.I. Load Short Form ; ,�,., =� t ��— Job: Fi i zs� '�.,' { t ! ,'� i Date: Entire House i� , �.-.�._�_ ..__ � j, ;� 1 By: RAL Supply MAR 21 2017 I ! 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • For: Chris Patten, Patten Property Developmen 266.3-1-73,5 RC-000106-2017 16 Ridgewood Ct, Queensbury, NY 12801 Patten Property Development,LLC Phone: 518-796-4654 16 Ridgewood Court 2585 Sf SFD w/484 Sf garage & 1 fireplace Design Informatioi-r— Htg Cig Infiltration Outside db (°F) -4 85 Method Simplified Inside db(OF) 70 75 Construction quality Loose Design TD (°F) 74 10 Fireplaces 1 (Semi-loose) Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/Ib) 52 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade goodman Model GCSS960804CN Cond GSX140241K' AHRI ref 7365099 Coil F,PE-E22(1,2)24 AHRI ref 8083905 Efficiency 96.1 AFUE Efficiency 10.5 EER, 14 SEER Heating input 80000 Btuh Sensible cooling 15400 Btuh Heating output 77000 Btuh Latent cooling 6600 Btuh Low output baseboard 500 Btuh/ft Total cooling 22000 Btuh Total low baseboard 150 ft Actual air flow 733 cfm High output baseboard 700 Btuh/ft Air flow factor 0.043 cfm/Btuh Total high baseboard 107 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 ROOM NAME Area Htg load Cig load Baseboard (ft) Cig AVF (ft2) (Btuh) (Btuh) Low High (cfm) Master bedroom 195 7031 1343 14 10 58 Family room 288 6088 1410 12 9 60 Bath WIC 187 5685 897 11 8 38 Foyer 176 4286 789 9 6 34 Dining room 143 4776 1535 10 7 66 Kitchen 242 5844 1212 12 8 52 bedroom 4 den 132 4438 843 9 6 36 mud room bath 108 4357 1439 9 6 62 bath and WIC 120 2564 443 5 4 19 Bedroom 3 182 6362 1926 13 9 83 bonus 264 8312 1833 17 12 79 bedroom 2 120 3131 1309 6 4 56 open foyer 176 5073 810 10 7 35 open family room 288 6624 1120 13 9 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wt'ightSOft Right-Suite® 2017-Mar-20 17:35 06 17.0.17 RSU25202 Page 1 jCC'�. ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N hall way 1 114 1 590 1 194 1 1 1 1 8 Entire House d 2735 75161 17104 150 107 733 Other equip loads 0 0 Equip. @ 0.90 RSM 15394 Latent cooling 3215 TOTALS I 2735 I 75161 18609 I 150 107 733 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. • ,,, W1"19f1tSOft Right-Su de®Universa1201717.0.17 RSU25202 2017-Mar-20 17:35:06Paget ..s WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N BuildingAnalysis Job: Y Date: Entire House By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bul b(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) • Component Btuh/ft2 Btuh % of load Walls 6.7 21316 28.4 Glazing 41.9 7876 10.5 VAI Doors 28.7 1806 2.4 Ceilings 2.4 6433 8.6 Infiltration Floors 2.8 7719 10.3 Infiltration 8.7 30010 39.9 Ducts 0 0 Piping 0 0 Gazing Humidification 0 sw 0 Ventilation 0 0 ` or, Boors Adjustments 0 Total 1 1 751611 100.0 Component Btuh/ftz Btuh % of load Walls 1.4 4524 26.5 Glazing 27.7 5202 30.4 Infiltration Doors 8.0 506 3.0 V\NI Aaors Ceilings 1.4 3860 22.6 Floors 0.4 1050 6.1 Infiltration 0.6 1962 11.5 Ducts 0 0 Ventilation 0 0 Ceilings Internal gains 0 0 Blower 0 0 Adjustments 0 Gazing Doors Total 1 1 171041 100.0 Latent Cooling Load = 3215 Btuh Overall U-value =0.072 Btuh/ft2-°F Data entries checked. wri htSOft Ri2017-Mar-2017:35:06 g ght-Suite®Universal 2017 17.0.17 RSU25202 ,4- ...s\WrightSoft projectslpatten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Page 1 Right-J® Worksheet Job: Entire House Date: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com 1 Room name Family room Bath WIC 2 Exposed wall 24.0 it 34.0 It 3 Room height 9.0 It heat/cool 9.0 it heat/cool 4 Room dimensions 18.0 x 16.0 It 11.0 x 17.0 ft 5 Room area 2880 ft2 187.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ftl-°F (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 6.69 1.42 162 126 843 179 0 0 0 0 1 D-c2ov 0.570 n 41.90 16.34 36 0 1508 588 0 0 0 0 12C-Osw 0.091 a 6.69 1.42 0 0 0 0 54 54 361 77 1 D-c2ov 0.570 e 41.90 58.12 0 0 0 0 0 0 0 0 1 1 11 DO 0.390 a 28.66 8.03 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1.42 0 0 0 0 99 99 662 141 1 D-c2ov 0.570 s 41.90 30.78 0 0 0 0 0 0 0 0 11 DO 0.390 s 28.66 8.03 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 6.69 1.42 54 54 361 77 153 153 1023 217 C 1613-30ad 0.032 2.35 1.41 288 288 677 406 187 187 440 264 F 19A-19bsco 0.049 2.82 0.38 288 288 813 111 187 187 528 72 F 19A-19bscp 0.049 2.82 0.38 0 0 0 0 0 0 0 0 61 c)AED excursion 1 -751 1 -47 Envelope loss/gain 4202 1286 1 1 3014 723 12 a) Infiltration 1885 123 2671 175 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 6088 1410 5685 897 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6088 1410 5685 897 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room lad1 97 LowlHigh Bao eboard/Cool Air 1 1 121 6089 146001 11 5688 8381 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsraft Right-Suite®Universal 2017 17.0.17 RSU25202 2017-Mar-2017:Paage 2ge2 '� ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Right-J® Worksheet Job: Entire House Date: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone.518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply com 1 Room name Foyer Dining room 2 Exposed wall 21.0 ft 23.0 It 3 Room height 9.0 it heat/cool 9.0 it heat/cool 4 Room dimensions 11.0 x 16.0 It 11 0 x 130 it 5 Room area 1760 ft' 143.0 ft2 Ty Construction U-valueOr HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vt,/ 12C-Osw 0 091 n 6.69 1 42 18 18 120 26 0 0 0 0 G 1 D-c2ov 0.570 n 41.90 16.34 0 0 0 0 0 0 0 0 12C-Osw 0.091 e 6.69 1.42 27 27 181 38 108 108 722 153 1 D-c2ov 0.570 e 41.90 58.12 0 0 0 0 0 0 0 0 1 1 11 DO 0.390 e 28.66 8.03 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1.42 99 78 522 111 99 75 502 106 1 D-c2ov 0 570 s 41.90 30.78 0 0 0 0 24 0 1005 739 11 DO 0.390 s 28.66 8.03 21 21 602 169 0 0 0 0 W 12C-Osw 0.091 w 6.69 142 45 45 301 64 0 0 0 0 C 16B-30ad 0.032 2.35 1.41 176 176 414 248 143 143 336 202 F 19A-19bsco 0.049 2.82 0.38 176 176 497 68 143 143 404 55 F 19A-19bscp 0.049 2.82 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -42 162 Envelope loss/gain 2636 681 1 1 2969 1417 12 a) Infiltration 1650 108 1807 118 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4286 789 4776 1535 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4286 789 4776 1535 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load4286 789 4776 1535 LowiHigh Baseboard/Cool Air 9 6I 34I I 10 7 66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �� wr[gfZtse�fY Right-Suite®Universal 201717.0.17 RSU25202 2017-Mar-2017.35.06 Page 3 _s\VVrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Right-J® Worksheet Job: Entire House Date: RAL Supply By: 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com 1 Room name Kitchen bedroom 4 den 2 Exposed wall 27.0 ft 23.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 11.0 x 22.0 ft 12.0 x 11.0 ft 5 Room area 242.0 ft' 132.0 ft' Ty Construction U-value Or I HTM Area (ft') I Load I Area (ft') Load numberperimeter (ft) (Btuh number (Btuh/ft'-°F (Btuh/f t') or perimeter (ft) (Btuh) or ) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V+/ 12C-Osw 0.091 n 6.69 1.42 99 75 502 106 108 92 615 131 �G 1D-c2ov 0.570 in 41.90 16.34 24 0 1005 392 16 0 670 261 12C-Osw 0.091 a 6.69 1.42 18 18 120 26 99 99 662 141 1 Dc2ov 0.570 e 41.90 58.12 0 0 0 0 0 0 0 0 1 1 11 DO 0.390 a 28.66 8.03 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1.42 81 81 542 115 0 0 0 0 1D-c2ov 0.570 s 41.90 30.78 0 0 0 0 0 0 0 0 11 DO 0.390 s 28.66 8.03 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 6.69 1.42 45 45 301 64 0 0 0 0 C 1613-30ad 0.032 2.35 1.41 242 242 569 342 132 132 310 186 F 19A-19bscp 0.049 2.82 0.38 242 242 683 93 132 132 373 51 F 19A-19bscp 0.049 2.82 0.38 0 0 0 0 0 0 0 0 61 c)AED excursion 1 -64 1 1 1 45 Envelope loss/gain 3722 1073 2631 725 12 a) Infiltration 2121 139 1807 118 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 5844 1212 4438 843 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5844 1212 4438 843 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load LowlH gh Bas board/Cool Air I 121 584$ 12521 I 9 4436 81 836 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 35 wrightsoft Right-Suite®Universal 2017 17.0.17 RSU25202 2017-Mar-2017: ._s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Paagege4 4 Right-J® Worksheet Job: Entire House Date: RAL Supply BY: 16 Corporate Dr,Clifton Park,NY 12065 Phone.518-956-1593 Fax.518-371-0511 Email:JZoller@ralsupply.com 1 Room name mud room bath bath and WIC 2 Exposed wall 21.0 ft 14.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 12.0 x 9.0 ft 12.0 x 10.0 ft 5 Room area 108.0 ft' 1200 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ftl-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vy 12C-Osw 0.091 n 6.69 1.42 0 0 0 0 108 108 722 153 I—G 1 D-c2ov 0.570 n 41.90 16.34 0 0 0 0 0 0 0 0 12C-Osw 0.091 e 6.69 1.42 81 69 462 98 18 18 120 26 1D-c2ov 0 570 e 41.90 58.12 12 0 503 697 0 0 0 0 1 1 11 DO 0 390 e 28.66 8.03 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1.42 108 87 582 124 0 0 0 0 L-", 1 D-c2ov 0 570 s 41 90 30.78 0 0 0 0 0 0 0 0 11 D0 0.390 s 2866 8.03 21 21 602 169 0 0 0 0 W 12C-Osw 0.091 w 6.69 1.42 0 0 0 0 0 0 0 0 C 16B-30ad 0-032 2.35 1 A 108 108 254 152 120 120 282 169 F 19A-19bsco 0.049 282 038 108 108 305 41 0 0 0 0 F 19A-19bscp 0.049 2.82 0.38 0 0 0 0 120 120 339 46 6 c)AED excursion 1 49 23 Envelope loss/gain 2707 1331 1 1 1464 371 12 a) Infiltration 1650 108 1100 72 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4357 1439 2564 443 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4357 1439 2564 443 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 4357 1439 2564 443 LowlHigh Baseboard/Cool Air 9 6 62 5 4 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightscsft Right-Suite®Universal 2017 17.017 RSU25202 2017-Mar-201735:06 s\WrIghtSoft projects\patten 6 ridgewood ct_rup Calc=MJ8 Front Door faces: N Page 5 Right-J® Worksheet Job: Entire House Date: RAL Supply By: 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com 1 Room name Bedroom 3 bonus 2 Exposed wall 35.0 ft 460 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 130 x 140 ft 12.0 x 22.0 ft 5 Room area 182.0 ft' 264.0 ft2 Ty Construction U-value Or HTM Area (ftp) Load Area (ft2) Load number (Btuh/ft'-.F (Bt uh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vt1 12C-Osw 0.091 n 6.69 1.42 117 117 783 166 0 0 0 0 L—G 1 D-c2ov 0.570 n 41.90 16.34 0 0 0 0 0 0 0 0 12C-Osw 0.091 e 6.69 1 42 126 110 736 156 198 198 1324 281 1 D-c2ov 0.570 e 41.90 58.12 16 0 670 930 0 0 0 0 1 1 11 DO 0-390 e 28.66 803 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1 42 72 72 482 102 108 92 615 131 L—"' 1 D-c2ov 0.570 s 41.90 30.78 0 0 0 0 16 0 670 493 11D0 0.390 s 28.66 8.03 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 669 1.42 0 0 0 0 108 108 722 153 C 1613-30ad 0.032 2.35 1 41 182 182 428 257 264 264 621 373 F 19A-19bscp 0.049 2.82 0.38 0 0 0 0 0 0 0 0 F 19A-19bscp 0.049 282 0.38 182 182 514 70 264 264 745 101 6 c)AED excursion 66 65 Envelope loss/gain 3612 1747 4698 1596 12 a) Infiltration 2750 180 3614 236 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 6362 1926 8312 1833 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6362 1926 8312 1833 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 6362 1926 8312 1833 Low11-ligh Baseboard/Cool Air 13 9 83 1 17 12 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed rT` wrightsoR Right-Suite®Universal 2017 17.0.17 RSU25202 2017-Mar-2017:35.06 _.s\WrightSoft projects\patten 6 ridgewood cl.rup Calc=MJS Front Door faces: N Page 6 Right-J® Worksheet Job: Entire House Date: RAL Supply By: 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email.JZoller@ralsupply.com 1 Room name bedroom 2 open foyer 2 Exposed wall 12.0 ft 30.0 ft 3 Room height 9.0 ft heat/cool 90 ft heat/cool 4 Room dimensions 12.0 x 100 ft 11.0 x 16.0 ft 5 Room area 120.0 ft' 176.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuhlft'-°F (8tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V(J 12C-Osw 0.091 n 6.69 1.42 0 0 0 0 0 0 0 0 L_ G 1 D-c2ov 0.570 n 41 90 16.34 0 0 0 0 0 0 0 0 12C-Osw 0.091 e 6.69 1.42 0 0 0 0 27 27 181 38 1 D-c2ov 0 570 e 41.90 58.12 0 0 0 0 0 0 0 0 1 1 11 DO 0 390 e 28.66 803 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1 42 108 84 562 119 99 99 662 141 1 D-c2ov 0.570 s 41.90 30.78 24 0 1005 739 0 0 0 0 11 DO 0.390 s 28.66 8.03 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 669 1.42 0 0 0 0 144 144 963 204 C 1613-30ad 0.032 2.35 1.41 120 120 282 169 176 176 414 248 F 19A-19bsco 0 049 2.82 0.38 0 0 0 0 0 0 0 0 F 19A-19bscp 0.049 2.82 0.38 120 120 339 46 176 176 497 68 6 c)AED excursion 174 43 Envelope loss/gain 2188 1247 1 1 2717 656 12 a) Infiltration 943 62 2357 154 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3131 1309 5073 810 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3131 1309 5073 810 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 3131 1309 5073 810 LowlHigh Baseboard/Cool Air 61' 4I 56 t0l 7I 35 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ��+ wrighi5off Right-Suite®Universal 201717.0.17RSU25202 2017-Mar-2017.3506 _s\WrightSoft projectslpatten 6 ridgewood ct rup Calc=MJ8 Front Door faces: N Page 7 Right-J® Worksheet Job: Entire House Date: RAL Supply By: 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com 1 Room name open family room hall way 2 Exposed wall 37.0 It 0 It 3 Room height 9.0 ft heat/cool 9.0 it heat/cool 4 Room dimensions 18.0 x 16.0 If 19.0 x 6.0 ft 5 Room area 288.0 ft2 114.0 ft' Ty Construction U-value Or HTM Area (ft ) Load Area (ft ) Load number (Btuh/ft'-°F (Btuh/ftz) or perimeter (ft) (Btuh or T z z perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross NIP/S Heat Cool 6 12C-Osw 0.091 n 6.69 1.42 162 162 1084 230 0 0 0 0 1 D-c2ov 0.570 n 41.90 16.34 0 0 0 0 0 0 0 0 12C-Osw 0.091 a 6.69 1.42 27 27 181 38 0 0 0 0 1 D-c2ov 0.570 e 41.90 58.12 0 0 0 0 0 0 0 0 1 1 11 DO 0.390 a 28.66 8.03 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 6.69 1.42 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 s 41.90 30.78 0 0 0 0 0 0 0 0 11 DO 0.390 s 28.66 8.03 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 6.69 1.42 144 144 963 204 0 0 0 0 C 16B-30ad 0.032 2.35 1.41 288 288 677 406 114 114 268 161 F 19A-19bsco 0.049 2.82 0.38 0 0 0 0 0 0 0 0 F 19A-19bscp 0.049 2.82 0.38 288 288 813 111 114 114 322 44 6 c)AED excursion -591 1 1 -10 Envelope loss/gain 3717 930 1 1 590 194 12 a) Infiltration 2907 190 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 6624 11201 590 194 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6624 1120 590 194 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load LowlH gh Bas board/Cool Air I 131 66291 11481 1 I 591 198 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Are�,P. -4d- wrightsaft Right-Suite®Universal 2017 17.0.17 RSU25202 2017-Mar-201 y 06 ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Page 8 Loads for Multiple Orientations Job: Date: Entire House By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry buI b(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Wetbulb(°F) - 71 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (6tuh) 15394 18367 19857 18691 16318 19884 20268 18084 Latent Load (Btuh) 3215 3215 3215 3215 3215 3215 3215 3215 Total Load (Btuh) 18609 21582 23072 21906 19533 23098 23483 21299 Heating AVF(cfm) 733 733 733 733 733 733 733 733 Cooling AVF(cfm) 733 733 733 733 733 733 733 733 Building Orientation Coding Load 2500 2000 1500 1000 500 0 N NE E SE S SW W NW ❑rection Fran Door fazes Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces West Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2017-Mar-2017:35:07 9 Right-Suite®Universal 2017 17.0.17 RSU25202 ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Page 1 Component Constructions Date: Entire House By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com roiec t Information For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bul b(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/W-°F ft2-°FBtuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 795 0.091 13.0 6.69 5317 1.42 1129 fnsh,Tx4"wood frim, 16"o.c.stud a 779 0.091 13.0 6.69 5210 1.42 1106 s 785 0.091 13.0 6.69 5250 1.42 1114 w 828 0.091 13.0 6.69 5538 1.42 1175 all 3187 0.091 13.0 6.69 21316 1.42 4524 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 96 0.570 0 41.9 4022 16.3 1569 thk;6.67 ft head ht a 28 0.570 0 41.9 1173 58.1 1627 s 64 0.570 0 41.9 2681 30.8 1970 all 188 0.570 0 41.9 7876 27.5 5166 Doors 11 DO:Door,wd sc type a 21 0.390 0 28.7 602 8.03 169 s 42 0.390 0 28.7 1204 8.03 337 all 63 0.390 0 28.7 1806 8.03 506 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 veil ins, 1/2" 2735 0.032 30.0 2.35 6433 1.41 3860 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm fir,8"thkns,carpet flr fnsh,r-19 cav ins,tight 1471 0.049 19.0 2.82 4152 0.38 565 bsmt ovr 1264 0.049 19.0 2.82 3567 0.38 485 all 2735 0.049 19.0 2.82 7719 0.38 1050 Wr7 htSOft 2017-Mar-2017:35:06 9 Right-Suite®Universal 2017 17.0.17 RSU25202 Page 1 ACCX ._s\WrightSoft projectslpatten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Date: Master bedroom By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com _-Proiect Information For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft' Btuh/`t2-0F ft?°F/Btuh Btuhff Btuh Btuh/ft' Btuh Walls 12C-Osw:Firm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 97 0.091 13.0 6.69 649 1.42 138 fnsh,2"x4"wood frm, 16"o.c.stud a 24 0.091 13.0 6.69 161 1.42 34 s 18 0.091 13.0 6.69 120 1.42 26 w 135 0.091 13.0 6.69 903 1.42 192 all 274 0.091 13.0 6.69 1833 1.42 389 Partitions (none) Windows 1 D-c2ov:2 glazing,clr outr,air gas,vnl firm mat,clr innr, 1/4"gap, 1/4" n 20 0.570 0 41.9 838 16.3 327 thk;6.67 ft head ht Doors 11 DO: Door,wd se type a 21 0.390 0 28.7 602 8.03 169 Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 195 0.032 30.0 2.35 459 1.41 275 gypsum board int fnsh Floors 19A-19bscp:Flr floor,firm flr,8"thkns,carpet flr fnsh, r-19 cav ins,tight 195 0.049 19.0 2.82 550 0.38 75 bsmt ovr W r'1 ihtsoft 2017-Mar-20 17:age35 2 9 Right-Sufte®Univ ersa1201717.0.17 RSU25202 Paget ,A—C-A _.s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Date: Family room By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ff-°F T-0 F/Btuh Btuh/ff Btuh Btuh/W Btuh Walls 12C-Osw: Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 126 0.091 13.0 6.69 843 1.42 179 fnsh,2'x4"wood frm, 16"o.c.stud w 54 0.091 13.0 6.69 361 1.42 77 all 180 0.091 13.0 6.69 1204 1.42 256 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 36 0.570 0 41.9 1508 16.3 588 thk;6.67 ft head ht Doors (none) Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 288 0.032 30.0 2.35 677 1.41 406 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm flr,8"thkns,carpet fir fnsh,r-19 cav ins,tight 288 0.049 19.0 2.82 813 0.38 111 bsmt ovr 35:06 Wright50ft Right-Suite®Universal 2017 17.0.17 RSU25202 2017-Mar-20 17:P3506 'CCk ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Date: Bath WIC By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project Information For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange(°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ff°F ft?°F/Btuh Btuh/ff Btuh Btuh/R' Btuh Walls 12C-Osw:Firm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int a 54 0.091 13.0 6.69 361 1.42 77 fnsh,2"x4"wood frm, 16"o.c.stud s 99 0.091 13.0 6.69 662 1.42 141 w 153 0.091 13.0 6.69 1023 1.42 217 all 306 0.091 13.0 6.69 2047 1.42 434 Partitions (none) Windows (none) Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 187 0.032 30.0 2.35 440 1.41 264 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm fir,8"thkns,carpet fir fnsh, r-19 cav ins,tight 187 0.049 19.0 2.82 528 0.38 72 bsmt ovr 06 : �� WrightSOflt Rig ht-Su ite®Universal201717.0.17RSU25202 2017-Mar-20 17:P 353506 ..s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Date: Foyer By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development (6 Ridgewood Ct, Queensbury, NY 12801 Phone'. 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft?°F ft'-'F/Btuh Btuh/ft' Btuh BtuhAV Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 18 0.091 13.0 6.69 120 1.42 26 fnsh,2"x4"wood frm, 16"o.c.stud a 27 0.091 13.0 6.69 181 1.42 38 s 78 0.091 13.0 6.69 522 1.42 111 w 45 0.091 13.0 6.69 301 1.42 64 all 168 0.091 13.0 6.69 1124 1.42 238 Partitions (none) Windows (none) Doors 11 DO:Door,wd sc type s 21 0.390 0 28.7 602 8.03 169 Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 176 0.032 30.0 2.35 414 1.41 248 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm flr,8"thkns,carpet fir fnsh,r-19 cav ins,tight 176 0.049 19.0 2.82 497 0.38 68 bsmt ovr � Wrightsoft Right-Sude® 2017-Mar-20 17:35:06 Universal 2017 17.0.17 RSU25202 ..s\WnghtSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Page 5 Component Constructions Job: Date: Dining room By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area 11.11-value Insul R Htg HTM Loss Cig HTM Gain ft' Btuh/ft'-°F ft'-°FOuh Btuh/112 Btuh BtuhV Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int a 108 0.091 13.0 6.69 722 1.42 153 fnsh,2"x4"wood frm, 16"o.c.stud s 75 0.091 13.0 6.69 502 1.42 106 all 183 0.091 13.0 6.69 1224 1.42 260 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4" s 24 0.570 0 41.9 1005 30.8 739 thk;6.67 ft head ht Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 143 0.032 30.0 2.35 336 1.41 202 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm fir,8"thkns,carpet flr fnsh, r-19 cav ins,tight 143 0.049 19.0 2.82 404 0.38 55 bsmt ovr wright5Oft Right-Suite®Universal 201717.0.17RSU25202 2017-Mar-20 17:35:06Page6 �� ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: Kitchen By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email JZoller@ralsupply com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Bhh/ft?°F T°F/Btuh Btuh/ft' Btuh Bhh/ft' Btuh Walls 12C-Osw:Firm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 75 0.091 13.0 6.69 502 1.42 106 fnsh,2"x4"wood frm, 16"o.c.stud a 18 0.091 13.0 6.69 120 1.42 26 s 81 0.091 13.0 6.69 542 1.42 115 w 45 0.091 13.0 6.69 301 1.42 64 all 219 0.091 13.0 6.69 1465 1.42 311 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 24 0.570 0 41.9 1005 16.3 392 thk;6.67 ft head ht Doors (none) Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 242 0.032 30.0 2.35 569 1.41 342 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm fir,8"thkns,carpet fir fnsh,r-19 cav ins,tight 242 0.049 19.0 2.82 683 0.38 93 bsmt ovr 2017-Mar-20 17:35:06 .Z � WrlghtSOft Right-Suite®Universal 2017 17.0.17 RSU25202 Page 7 ..s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: bedroom 4 den By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area 1.11-value Insul R Htg HTM Loss Cig HTM Gain ft' Btuh/ft'-°F ft'-°F/Btuh Btuh/ft' Btuh Btuh/112 Btuh Walls 12C-Osw: Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 92 0.091 13.0 6.69 615 1.42 131 fnsh,2"x4"wood frm, 16"o.c.stud a 99 0.091 13.0 6.69 662 1.42 141 all 191 0.091 13.0 6.69 1278 1.42 271 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 16 0.570 0 41.9 670 16.3 261 thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 132 0.032 30.0 2.35 310 1.41 186 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm fir,8"thkns,carpet fir fnsh,r-19 cav ins,tight 132 0.049 19.0 2.82 373 0.38 51 bsmt ovr „` Wfl htSOft 2017-Mar-2017:35:06 9 Right-Suite®Universal201717.0.17RSU25202 ACC4141 ..s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Page Component Constructions Job: Date: mud room bath By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/W-°F W-*F/Btuh Btuh/ft' Btuh Btuh/ft2 Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int a 69 0.091 13.0 6.69 462 1.42 98 fnsh,2'x4"wood frm, 16"o.c.stud s 87 0.091 13.0 6.69 582 1.42 124 all 156 0.091 13.0 6.69 1043 1.42 221 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" a 12 0.570 0 41.9 503 58.1 697 thk;6.67 ft head ht Doors 11 DO:Door,wd sc type s 21 0.390 0 28.7 602 8.03 169 Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins, 1/2" 108 0.032 30.0 2.35 254 1.41 152 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm fir,8"thkns,carpet fir fnsh, r-19 cav ins,tight 108 0.049 19.0 2.82 305 0.38 41 bsmt ovr 2017-Mar-20 17:35:06 WrlghtSofk Right-Suite®Universal 2017 17.0.17 RSU25202 Page -4CCA ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: bath and WIC By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Clg HTM Gain ft' Btu M°F ft?°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 108 0.091 13.0 6.69 722 1.42 153 fnsh,2"x4"wood frm, 16"o.c.stud a 18 0.091 13.0 6.69 120 1.42 26 all 126 0.091 13.0 6.69 843 1.42 179 Partitions (none) Windows (none) Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 120 0.032 30.0 2.35 282 1.41 169 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm flr,8"thkns,carpet flr fnsh, r-19 cav ins,tight 120 0.049 19.0 2.82 339 0.38 46 bsmt ovr � WrtgFILSOft Right-Suit2017-Mar-20 17:35:06 e®Universal 2017 17.0.17 RSU25202 Page 10 ..s\WrightSoft projects\patten 6 hdgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Date: Bedroom 3 By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wet bulb(OF) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/W-°F T-0 F/Btuh Bkhlft' Btuh Btuh/ft' Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 117 0.091 13.0 6.69 783 1.42 166 fnsh,2"x4"wood frm, 16"o.c.stud a 110 0.091 13.0 6.69 736 1.42 156 s 72 0.091 13.0 6.69 482 1.42 102 all 299 0.091 13.0 6.69 2000 1.42 424 Partitions (none) Windows 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" a 16 0.570 0 41.9 670 58.1 930 thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins, 1/2 182 0.032 30.0 2.35 428 1.41 257 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm flr,8"thkns,carpet fir fnsh,r-19 cav ins,tight 182 0.049 19.0 2.82 514 0.38 70 bsmt ovr 2017-Mar-20 17:35:06 wrightsaft Right-Suite®Universal 2017 17.0.17 RSU25202 Page 11 ACa'+ ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: bonus By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com _-Proiect Information- For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 51.7 26.5 Dry bul b(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BhtUft-°F ft?°F/Btuh Btuh/ff Stun Btuh/ft' Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int a 198 0.091 13.0 6.69 1324 1.42 281 fnsh,2'x4"wood frm, 16"o.c.stud s 92 0.091 13.0 6.69 615 1.42 131 w 108 0.091 13.0 6.69 722 1.42 153 all 398 0.091 13.0 6.69 2662 1.42 565 Partitions (none) Windows 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" s 16 0.570 0 41.9 670 30.8 493 thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 264 0.032 30.0 2.35 621 1.41 373 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm fir,8"thkns,carpet fir fnsh, r-19 cav ins,tight 264 0.049 19.0 2.82 745 0.38 101 bsmt ovr 2017-Mar-20 17:35:06 WrightSOft Right-Suite®Universal 2017 17.0.17 RSU25202 Page 12 IC CA s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: bedroom 2 By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Bluhlt'°F ft2-°F/Btuh Btuh/ft2 Btuh Btuh/W Btuh Walls 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int s 84 0.091 13.0 6.69 562 1.42 119 fnsh,2"x4"wood frm, 16"o.c.stud Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" s 24 0.570 0 41.9 1005 30.8 739 thk;6.67 ft head ht Doors (none) Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 120 0.032 30.0 2.35 282 1.41 169 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm fir,8"thkns,carpet flr fnsh, r-19 cav ins,tight 120 0.049 19.0 2.82 339 0.38 46 bsmt ovr wrl htSOft 2017-Mar-2017:35:06 9 Right-Suiten Universa12017 17.0.17 RSU25202 Page 13 �'^ ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: open foyer By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft?°F T°F/Btuh Btuh/112 Stuh BtuhA2 Btuh Walls 12C-Osw: Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int a 27 0.091 13.0 6.69 181 1.42 38 fnsh,2"x4"wood frm, 16"o.c.stud s 99 0.091 13.0 6.69 662 1.42 141 w 144 0.091 13.0 6.69 963 1.42 204 all 270 0.091 13.0 6.69 1806 1.42 383 Partitions (none) Windows (none) Doors (none) Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 176 0.032 30.0 2.35 414 1.41 248 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm flr,8"thkns,carpet fir fnsh,r-19 cav ins,tight 176 0.049 19.0 2.82 497 0.38 68 bsmt ovr 2017-Mar-20 17:35:06 wrightsoft Right-Suite®Universal 2017 17.0.17 RSU25202 Page 14 ACS ...s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MA Front Door faces: N Component Constructions Date: open family room By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax 518-371-0511 Email:JZoller@ralsupply.com Project • • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 430N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 51.7 26.5 Dry bul b(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft?'F ft'-°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 12C-Osw: Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int n 162 0.091 13.0 6.69 1084 1.42 230 fnsh,2"x4"wood frm, 16"o.c.stud a 27 0.091 13.0 6.69 181 1.42 38 w 144 0.091 13.0 6.69 963 1.42 204 all 333 0.091 13.0 6.69 2227 1.42 473 Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat, r-30 ceil ins, 1/2" 288 0.032 30.0 2.35 677 1.41 406 gypsum board int fnsh Floors 19A-19bscp:Flr floor,frm flr,8"thkns,carpet fir fnsh,r-19 cav ins,tight 288 0.049 19.0 2.82 813 0.38 111 bsmt ovr 2017-Mar-20 17:35:06 ;t, WrightSoft Right-Suite®Universal 2017 17.0.17 RSU25202 Page 15 X-C ...s\WrightSoftprojects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Component Constructions Job: M Date: hall way By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project Information For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) Method Simplified Wetbulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/fF-°F ft'-°F/Btuh Btuh/ff Stun Btuh/ft' Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins, 1/2" 114 0.032 30.0 2.35 268 1.41 161 gypsum board int fnsh Floors 19A-19bscp:Fir floor,frm fir,8"thkns,carpet flr fnsh,r-19 cav ins,tight 114 0.049 19.0 2.82 322 0.38 44 bsmt ovr 2017-Mar-20 17:35:06 Wr'"tghtSoft Right-Suite®U niversal 2017 17.0.17 RSU25202 Page 16 s\WrightSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N Project Summary Date: Entire House By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Proeect Information For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Notes: Desi-qn Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 74 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 75161 Btuh Structure 17104 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 75161 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 15394 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Loose Fireplaces 1 (Semi-loose) Structure 3215 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2735 2735 Equipment latent load 3215 Btuh Volume(ft3) 24615 24615 Air changes/hour 0.92 0.44 Equipment total load 18609 Btuh Equiv. AVF (cfm) 376 181 Req. total capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade goodman Model GCSS960804CN Cond GSX140241 K* AHRI ref 7365099 Coil F,PE*E22(1,2)24 AHRI ref 8083905 Efficiency 96.1 AFUE Efficiency 10.5 EER, 14 SEER Heating input 80000 Btuh Sensible cooling 15400 Btuh Heating output 77000 Btuh Latent cooling 6600 Btuh Low output baseboard 700 Btuh/ft Total cooling 0.043 cfm/Btuh Total low baseboard 107 ft Actual air flow 0 in H2O Hi h output baseboard Air flow factor 0.84 Total high baseboard Static pressure Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -� � #� 2017-Mar-2017:35:06 w Right-Suite®Universal 2017 17.0.17 RSU25202 Page 1 .d;,GN ...s\WrlghtSoft projects\patten 6 ridgewood ct.rup Calc=MJ8 Front Door faces: N AED Assessment Job: Date: Entire House By: RAL Supply 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com Project • For: Chris Patten, Patten Property Development 16 Ridgewood Ct, Queensbury, NY 12801 Phone: 518-796-4654 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Dailyrange (°F) - 22 ( M ) VVet bulb(°F) - 71 Wind speed (mph) 15.0 7.5 Test for • - • Exposure Diversity Hourly Glazing Load 9, 8,000-- 7, 6,000-- 5,00D-- 4,000- 3, ,5,4,3, Z 1,000-- 01 8 9 10 11 12 13 14 15 16 17 18 19 20 Hxr d Day Ftxrfy Av-ege /AED limit Maximum hourly glazing load exceeds average by 30.6%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 36 Btuh (PFG - 1.3*AFG) Oft 2017-Mar-2017:35:06 WTI hLS Right-Suite®Universal 2017 17.0.17 RSU25202 Pagel .0 C;N ...slwrightSoft projectslpatten 6 ridgewood ct.rup Calc=MA Front Door faces: N Right-J® Worksheet Job: Entire House Date: RAL Supply By. 16 Corporate Dr,Clifton Park,NY 12065 Phone:518-956-1593 Fax:518-371-0511 Email:JZoller@ralsupply.com 1 Room name Entire House Master bedroom 2 Exposed wall 382.0 ft 35.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 13.0 x 15.0 ft 5 Room area 2735.0 ft' 195.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 6.69 1.42 891 795 5317 1129 117 97 649 138 1 Dc2ov 0.570 n 41.90 16.34 96 0 4022 1569 20 0 838 327 12C-Osw 0.091 a 6.69 1.42 828 779 5210 1106 45 24 161 34 1 D-c2ov 0.570 e 41.90 58.12 28 0 1173 1627 0 0 0 0 11 11D0 0.390 a 28.66 8.03 21 21 602 169 21 21 602 169 12C-Osw 0.091 s 6.69 1.42 891 785 5250 1114 18 18 120 26 1 Dc2ov 0.570 s 41.90 30.78 64 0 2681 1970 0 0 0 0 11D0 0.390 s 28.66 8.03 42 42 1204 337 0 0 0 0 W 12C-Osw 0.091 w 6.69 1.42 828 828 5538 1175 135 135 903 192 C 16B-30ad 0.032 2.35 1.41 2735 2735 6433 3860 195 195 459 275 F 19A-19bscp 0.049 2.82 0.38 1471 1471 4152 565 195 195 550 75 F 19A-19bscp 0.049 2.82 0.38 1264 1264 3567 485 0 0 0 0 6 c)AED excursion 1 36 1 1 1 71 Envelope loss/gain 45150 15142 4282 1164 12 a) Infiltration 30010 1962 2750 180 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 75161 17104 7031 1343 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 75161 17104 7031 1343 15 Duct loads 0% 0% 0 0 _0% 0% 0 0 Total room load 1611LowlH gh Bas board/Cool Air I 1501 751071 17104 733 141 701101 1358 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wrightsaft 2017-Mar-2017:35:06 Right-Suite®Universal 2017 17.0.17 RSU25202 �: 1 ._s\WnghtSoft projects\patten 6 ndgewood ct.rup Calc=MJ8 Front Door faces: N Page 1 Generated by REScheck-Web Software Compliance Certificate - � Project Plan NO.2585-17-PATTEN MAR 21 2017 Energy Code: 2015 IECC T0.a'i l I .` Location: Warren County, New York 0.9.. Er-y - Construction Type: Single-familyd Project Type: New Construction Orientation: Bldg. faces 315 deg. from North 266.3-1-73.5 RC-000106-2017 Conditioned Floor Area: 2,585 ft2 Patten Property Develo ment,LLC Glazing Area 14% p Climate zone: 6 (8499 HDD) 16 Ridgewood Court Permit Date: 2585 sf SFD w/484 sf garage & 1 fireplace Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 16 RIDGEWOOD CT PATTEN PROPERTY DEVELOPMENT JESSICA CHENIER BULMAN QUEENSBURY, New York 12804 7 JACKSON RD WILLIAMS&WILLIAMS DESIGNERS SOUTH GLENS FALLS, New York 509 GLEN ST 12803 GLENS FALLS, New York 12801 518-796-4564 518-798-4687 compliance:Passes using UA trade-off Compliance: 3.4%Better Than Code Maximum UA: 437 Your UA: 422 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter Ceiling: Raised or Energy Truss 1,756 38.0 0.0 0.025 44 Ceiling: Flat or Scissor Truss 288 38.0 0.0 0.030 9 Wall: Wood Frame, 16in. o.c. 509 21.0 0.0 0.057 24 Orientation: Front Window: Vinyl Frame, 2 Pane w/Low-E 54 0.250 14 Orientation: Front Door: Solid 40 0.140 6 Orientation: Front Wall: Wood Frame, 16in.o.c. 366 21.0 0.0 0.057 20 Orientation: Right side Window:Vinyl Frame, 2 Pane w/Low-E 13 0.250 3 Orientation: Right side Wall: Wood Frame, 16in. D.C. 509 21.0 0.0 0.057 19 Orientation: Back Window: Vinyl Frame, 2 Pane w/Low-E 115 0.250 29 Orientation: Back Door: Glass 63 0.300 19 Orientation: Back Wall: Wood Frame, 16in.o.c. 364 21.0 0.0 0.057 20 Orientation: Left side 6 0.250 2 Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 1 of 11 v 1 Gross Area Cavity Cont. Perimeter Wall: Wood Frame, 16in. o.c. 364 21.0 0.0 0.057 16 Orientation: Front Window: Vinyl Frame, 2 Pane w/Low-E 92 0.250 23 Orientation: Front Wall: Wood Frame, 16in, o.c. 293 21.0 0.0 0.057 15 Orientation: Right side Window: Vinyl Frame, 2 Pane w/Low-E 30 0.250 8 Orientation: Right side Wall: Wood Frame, 16in. o.c. 198 21.0 0.0 0.057 11 Orientation: Back Wall: Wood Frame, 16in. o.c. 134 21.0 0.0 0.057 8 Orientation: Left side Basement: Solid Concrete or Masonry 485 21.0 0.0 0.042 20 Orientation: Front Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Basement:Solid Concrete or Masonry 145 21.0 0.0 0.042 6 Orientation: Right side Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Basement:Solid Concrete or Masonry 146 21.0 0.0 0.050 7 Orientation: Right side Wall height: 9.0' Depth below grade: 5.0' Insulation depth: 9.0' Basement:Wood Frame 56 21.0 0.0 0.041 2 Orientation: Right side Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Basement: Solid Concrete or Masonry 43 21.0 0.0 0.039 2 Orientation: Back Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Basement:Wood Frame 442 21.0 0.0 0.041 18 Orientation: Back Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Basement: Solid Concrete or Masonry 156 21.0 0.0 0.050 8 Orientation: Left side Wall height: 9.0' Depth below grade: 5.0' Insulation depth: 9.0' Basement: Solid Concrete or Masonry 157 21.0 0.0 0.042 7 Orientation: Left side Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Basement:Wood Frame 156 21.0 0.0 0.041 6 Orientation: Left side Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Floor: All-Wood JoistlTruss Over Uncond. Space 484 38.0 0.0 0.026 13 Floor: All-Wood Joist/Truss Over Outside Air 23 38.0 0.0 0.026 1 Floor: Heated Slab-On-Grade 62 10.0 0.684 42 Insulation depth: 4.0' Project Title: Plan N0.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 2 ofll Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Jessica Chenier Bulman 7ezica Cheniey rdwtail 03/14/17 Name-Title Signature Date Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 3 of 11 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.1D 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. _ 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: []Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 !High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Plan N0.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 4 of 11 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? I Comments/Assumptions & Re .ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. ±d E] Heated E] Heated []Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [F03]1 depth/length. ❑Does Not table for values. to ❑Not Observable ❑Not Applicable 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interior R- R- ❑ Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not V, manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not V insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not [—]Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Plan N0.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 5 of 11 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor, U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable _ ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- []Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products []Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable _ ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 <. ❑Not Observable or has infiltration rates per NFRC i 400 that do not exceed code ❑Not Applicable limits. 1402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. [:]Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is []Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids []Does Not below 55°F are insulated to >_R- []Not Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not +, ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 !Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 6 of1I Additional Comments/Assumptions: 1 i High Impact(Tier 1) j 2 (Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 7 of 11 Section Plans Vered Field Verified # Insulation Inspection & ReqID Value Value Complies? Comments/Assumptions . 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- [ Complies See the Envelope assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel � ❑Not Observable ❑Not Applicable _----__,_..__. 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN211 in substantial contact with the Er underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN311 exterior,the exterior insulation Mass Mass ❑Not Observable 01 requirement applies (FR10). ❑ Steel ❑ Steel []Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. []Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 j High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Plan N0.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 8 of 11 Section Plans Verified Field Verified # Final Inspection Provisions ValueValue Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel Not Observable 402.2.6 ❑ [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not (F1211 Blown insulation marked every 300 ft2. []Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- []Complies (F13]1 insulation >_R-value of the []Does Not adjacent assembly. []Not Observable _ []Not Applicable 402.4.1.2 Blower door test @ 50 Pa-.<=5� ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. (--]Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a []Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow, []Not Observable []Not Applicable 403.1.1 Programmable thermostats ❑Complies [F 19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to [:]Not Observable code specifications. []Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not []Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 9 of 11 _____------- _-- Section i i -- p Plans Verified Field Verified # Final Ins —_plies? Comments/Assumptions I Inspection Provisions Com & Re ID I Value I Value 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy []Not Observable and air flow limits. []Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor []Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F[29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the []Not Observable heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies l[F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated [-]Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units _❑Complies [F[31]2 tested in accordance with C5A ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F[23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) ! 3 1 Low Impact(Tier 3) Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 10 of 11 Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions & Req.ID Value Value 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable _ ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable []Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ( 3 Low Impact(Tier 3) j Project Title: Plan NO.2585-17-PATTEN Report date: 03/14/17 Data filename: Page 11 of 11 2015 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 21.00 Floor 38.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.25 Door 0.30 CoolingHeating& Heating System• Cooling System: Water Heater: Name: Date: Comments o M a N � � s N C y a N J otS •S b a' Z f�-I�� �'����•� v a °a •5' o E R aw bw q °�q $� 12, ev.0 4 m $ IAL to t'-'; v o C•yyy C �. c M v 3 y p.yp,� 0 " v a 0 'a° � o �0b& Sb mm "085 b.°0 �'i w "� N [� '�0'aG '.(— �J� �an•.e� � �0 2 '4, .o C° .a m�b�'a� ppppm` ���? o� C m•3 Q � c��p pm� _ �t:, ���� S � �a h 4 p ti ti H N M v7 Iri 16 n O Q N O m — — — — — LZ'601 M1.0 N o90S a -------------------------- _ I I /roa ' oh /ti co Z o hto �I z � V• N L �2 h 10 �ro 1�Z e C�40 £6661 M„£1Z£o00ri q o I O J133 Consulting Joseph Biss III 553 State Route 149 - Suite B Lake George,New York 12845-3515 Phone: (518) 761-9888 JBISS3@AOL.COM NYSDOH Lab ID# 11637 Client: Parker Water Wells PO Box 627 East Poultney, VT 05741 Phone: (802) 287-4016 E-mail: parkerwaterwells@gmail.com Results: Pressure Tank— 16 Ridgewood—Queensbury,NY 12804 Sample Date115me Date Date/Time Analysis Method Result NxsDox Number Collection Received Analysis Drinking 170809H01 08/09/17 08/09/17 08/09/17 Total SM 9222s I <1 CFU/100 <1 CFU/100 10:45 A 4:30 P Coliform 2006 nil ml The results relate only to the sample(s) as received by the laboratory. The sample received was analyzed in compliance with NYSDOH and NELAP approved methods and within their accepted holding times. The result(s)is (are) equal to or lower than the State's limits therefore it (they) meets the requirements for NYSDOH Part 5 Drinking Water Regulations. JB3 Consulting's liability for any work performed is limited to the amount billed to the customer leading to the claim of the customer. Jo h Bi III yst/Dtrector Thursday, August 10, 2017 This is an original Certificate of Analysis, do not duplicate This is page 1 of 1 Y A