Loading...
RC-000057-2017 TOWN OF QUEENSBURY Bay Queensbury,� p y Road,Q ury,NY 12804-5904 (518)761-8201 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000057-2017 Date Issued: Thursday, April 5, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000057-2017 has been completed. Tax Map Number: 296.19-1-17.1 Location: 68 GLENWOOD AVE Owner: Doris O'Connor, Robert O'Connor Applicant: This structure may be occupied as a: Residential Addition 235 sq. ft. Residential Alteration 1,675 sq. ft. By Order of Town Board garage addition 530 sq. ft. TOWN OF QUEENSBURY 1 gas fireplace in masterbedroom Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000057-2017 Tax Map No: 296.19-1-17.1 Permission is hereby granted to: Robert O'Connor For property located at: 68 GLENWOOD AVE In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Doris O'Connor Single Family-Addition $200,000.00 Owner Address: 68 GLENWOOD AVE Total Value $200,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency V&H Construction,Inc. PO Box 136 Fort Edward,NY 12828 Plans&Specifications Residential Addition 235 sq.ft. Residential Alteration 1,675 sq.ft. garage addition 530 sq.ft. 1 gas fireplace in masterbedroom $480.75 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,March 28,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Wu;ptor 2017 SIGNED BY: the Town of Queensbury. Director of Building&Code Enforcement 7i+��-}", 11— --;__ vi aav—i viii <— t __x .iivi, kJ11K;G UJG"My Permit No. t\ Tax Map ID - Permit Fee Zone , oric? Yes v/No Re 7i7sit 2" ' Subdivision Name N f�. Lot# Su iProject Location $ (�tWM10FEB 2 1 2017TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single fa i y,d lexes/two-family, ily, apartments,condominiums,townhouses,and/or manufactured&modular homes,but n t rr sE'V�1� the permit fee(s). COMMUNITY DEVELOPMENT Primary Owner(s) t�;;6194 S Address /""p Phone/Email I N Applicant Gt�Jnlv�- Address Phone/Email Contractor Address PhonefEmail Contact Person for Building&Codes Compliance: Aij pLb, Phone TYPE OF CONSTRUCTION ,"Check all that apply New Addition Alteration 1st floor sf 2'floor sf Total sf Height Single Family V36 pray t A" 16'76 Two-Family Multi-Family � �IE C � Y (#of units_) 1 11 Townhouse I FEB 2 3 2 7 LI-Ji L Business Office TOS N OF OUE SB�URY Retail-Mercantile Factory-Industrial Attached Garage G2� (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 Iftommercial or industrial please indicate name of business tAJ. Proposed use of building or addition SINS tt:7C 7-Jag=_ Source of Heat(circle one) as Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? �d Are there easements on the property? NV14OV44 Site Information: a. Dimensions or acreage of lot /�,bQj Aac�5 b. Is this a corner lot? Yes _// No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well (circle one) ubli Private e. Sewer or Private Septic System(circle one) ewe Private Value of all work to be performed(labor or materials) $ 1pb low DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 15PA- V,. )Y - luA:PUcf JT- SIGNATURE: DATE: , ZOO For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Al, 22 se MX Ont DATE: Fig? 20 C1 L� d y" 37F,- t ID TAx MAP ID: Zgto• tq._ 1-17, 1 t I$ FEB 2 1 2017 ZONE: M ee TOWN OF QUEENS URY COMMUNITY DEVELOPMENrl OWNERvow + JI''LOIaN�� PHONE/E-MAIL ADDRESS � + INSTALLER/ �� /� .1.. 1�l {SOU`► PHONE/E�-MAIL BUILDER `� _ i _I2P CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: w PHONE/E-MAIL C;!Z46 BUILDING ADDRESS � (/txUQ 15 ROOM OF INSTALL: M -. LANNED INSTALL DATE: ��� lNn FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: FIREPLACE,MASONRY MANUFACTURER'S FURNACE(GARAGE ONLY) INSTALLATION MANUAL MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: Listed by: Number: rE Dill 11 LI CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE TOW,, O ().UEENSRlRy J_ Flue TIE STEEL Size in inch Material DOUBLE WALL —TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Load hort Form Job: Corhouse-O'Connor pii t Date: 03/13/17 entire House MAR 2 0 2017 By: Bill Venner O'Connor Resicence For: Corhouse Construction O'Conner Residence, 68 Glenwood Ave., NY 12804 .... . ._.......... .. ...... �:-..:,�� }11;71•1i:fir:it Htg Cig Infiltration Outside db(°F) -20 95 Method Simplified Inside db(°F) 70 72 Construction quality Average Design TD (°F) 90 23 Fireplaces 0 Daily range - M Inside humidity(°lo) 30 50 Moisture difference(gr/Ib) 31 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Utica Trade LG MINI SPLIT Model MGB-125J Cond LMU36CHV AHRI ref Coil AHRI ref Efficiency 82AFUE Efficiency 22 SEER Heating input 125000 MBtuh Sensible cooling 0 Btuh Heating output 104000 Btuh Latent cooling 0 Btuh Low output baseboard 580 Btuh/ft Total cooling 0 Btuh Total low baseboard 152 ft Actual air flow 1837 cfm High output baseboard 730 Btuh/ft Air flow factor 0.053 cfm/Btuh Total high baseboard 121 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Cig load Baseboard(ft) Clg AVF (ft2) (Btuh) (Btuh) Low High (cfm) Entry 102 11881 3542 20 16 189 Powder Room 28 1736 610 3 2 33 Kitchen 273 6027 3267 10 8 175 Dining Room 294 9662 3931 17 13 210 Laundry Room 57 2226 1968 4 3 105 Master Bath 140 7228 2964 12 10 159 Master WIC 95 1724 554 3 2 30 Master Bedroom 247 15081 5806 26 21 310 Living Room 384 13632 3878 24 19 207 2nd Floor 840 18870 7839 33 26 419 FILE Calculations approved byACCA to meet all requirements of Manual J 7th Ed. 2017-Mar-16 09:54:01 W rightSOf t Right-Suite®Universal 2012 12.1.05 RSU18342 Page 1 ACCP, ...rightsoftWAC2011\WrightsoftHVAC2012\Corhouse-o'Connouup Calc=MJ7 FrontDoorfaces. Entire House d 2459 88067 34358 152 121 1837 Other equip loads 0 0 Equip. @ 1.00 RSM 34358 Latent cooling 5274 TOTALS 2459 88067 39631 152 121 1837 Calculations approved byACCA to meet all requirements of Manual J 7th Ed. wri ht5oft zo,7-Mar-lsos:age2 g Right•Suite®Universal 201212.1.05 RSU18342 Page 2 ACCA ...rightsoftHVAC2011\WrightsoftHVAC2012\Corhouse-O'Connorrup Calc=MJ7 FrontDoorlaces: REScheck Software Version 4.6.3 - Compliance Certificate FEB 2 1 2011 TOWN OF QUEENSBURY Project Renovations to the O'Connor Residence COMMUNITY DEVELOPMENT Energy Code: 2015 IECC Location: Glens Falls, New York IE C Construction Type: Single-family L� Project Type: Addition Climate Zone: 6 (7635 HDD) FEB 2 3 2017 l Permit Date: " Permit Number: TOWN OF QUE ;NSBURY Construction Site: Owner/Agent: Designer/C` ra-BALDING& CODES 68 Glenwood Ave Robert&Doris O'Connor Ethan Peter Hall Queensbury, NY 12804 68 Glenwood Ave Rucinski Hall Architecture ueensbury, NY 12804 134 Dix Ave Glens Falls, NY 12801 :COP Y Y518-741-0268 EIn L ephall@nycap.rr.com ,Compliance: Passes using UA trade-off Compliance: 1.7%Better Than Code Maximum UA: 58 Your UA: 57 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling 1: Raised or Energy Truss 333 38.0 0.0 0.025 8 Wall 1: Wood Frame, 16"o.c. 394 21.0 5.0 0.043 14 Window 1:Wood Frame:Double Pane with Low-E 42 0.320 13 Door 1: Solid 38 0.300 11 Crawl 1: Solid Concrete or Masonry 272 15.0 0.0 0.073 11 Wall height: 6.9' Depth below grade: 5.0' Insulation depth: 6.5' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requireme is lisAdithe heck Inspection Checklist. Ethan Peter Hall-Architect G(/ i AtZ Name-Title Si re Date 296.19-1-17.1 RC-000057-2017 O'Connor, Robert & Doris 68 Glenwood Avenue Res. Add./Alt., Garage Add., FP Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 1 of 9 REScheck Software Version 4.6.3 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PRI]1 energy code compliance for the []Not Observable Location on plans/spec: A- building envelope.Thermal 1 envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for Not Observable Location on plans/spec: A- [PR3I1 lighting and mechanical systems. ❑ 1 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location on plans/spec: A- Manual J or other methods Btu/hr Btu/hr 1 approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies [F0711 insulation R-value. R- R- ❑Does Not table for values. ❑Not Observable ❑Not Applicable 303.2 Unvented crawl space wall ❑Complies Requirement will be met. [F0811 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 402.2.11 Unvented crawl space continuous ❑Complies Requirement will be met. [F0911 vapor retarder installed over ❑Does Not exposed earth,joints overlapped ❑Not Observable Location on plans/spec:A- by 6 in.and sealed,extending at 1 least 6 in. up and attached to the ❑Not Applicable wall. 402.2.11 Unvented crawl space wall in. in. ❑Complies See the Envelope assemblies [FO10]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. -]Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Exception: Requirement is [FO11]2 to protect exposed exterior ❑Does Not not applicable. insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO12]2 controls installed. ❑Does Not not applicable. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 []Does Not table for values. [FR1]1 ❑Not Observable !f ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 is 303.1.3 U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable Location on plans/spec: A- taken from the default table. 1 ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 402.4.3 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not at AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Exception: Requirement is [FR16]2 sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate .52.0 cfm leakage at 75 Pa. []Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the >= 3 inches in diameter and >= ❑Not Observable building envelope. R-6 where < 3 inches. Supply and return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable Location on plans/spec: A- ❑Not Applicable 1 403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is [FR17]2 above 105 QF or chilled fluids ❑Does Not not applicable. below 55 QF are insulated to >_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is [FR24]1 piping. ❑Does Not not applicable. +yl ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies Exception: Requirement is [FR18]2 >_R-3. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable Location on plans/spec: A- 1 ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 4 of 9 Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 exterior,the exterior insulation V requirement applies(FR10). E] Steel E] Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 ❑Not Applicable [FI1]1 PP 303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑Not Observable Location on plans/spec: A- 300 ft2. ❑Not Applicable 1 402.2.3 Vented attics with air permeable ❑Complies Exception: Requirement is [FI22]2 insulation include baffle adjacent ❑Does Not not applicable. to soffit and eave vents that extends over insulation. []Not Observable ❑Not Applicable _ 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable Location on plans/spec:A- 1 []Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within <=3 cfm/100 ft2 without air ❑Not Observable conditioned space. handler @ 25 Pa. For rough-in tests,verification may need to []Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception: All ducts and air [FI27]1 determine air leakage with ft2 ft2 ❑Does Not handlers are located within either: Rough-in test:Total ❑Not Observable conditioned space. leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g, across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Exception: Requirement is [FI24]1 by manufacturer at<=2%of ❑Does Not not applicable. design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable Location on plans/spec:A- initially set by manufacturer to 1 code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is [F[10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Exception: Requirement is [Fl 11]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 7 of 9 Section Plans VerifiedP ield Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies Requirement will be met. [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable Location on plans/spec:A- and air flow limits. ❑ 1 Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [FI26]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is [F128]2 have a circulation pump.The ❑Does Not not applicable. system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists._ 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [FI29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [F130]2 have recirculation pumps that ❑Does Not not applicable. pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies Exception: Requirement is [FI31]2 tested in accordance with CSA ❑Does Not not applicable. 855.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Location on plans/spec: A- Does not apply to low-voltage 1 lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [F123]3 no continuous pilot light. ❑Does Not +;+ ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 8 of 9 Section Plans VerifiedField Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Renovations to the O'Connor Residence Report date: 02/17/17 Data filename: Y:\O'Connor Glenwood Ave\Const Dwg's\O'Connor.rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 26.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.32 Door 0.30 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Date: Comments 'i - II 1, YI„Lil l„1i 11111111,1111 4,11111III Idh IdIVI iIla61V1111Y 111Ill i10111,10V II;I 11 IIJI I,Ii IIuWIiI A i111 = I GENERAL NOTES 3 INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM - A SURVEY DRAWING PREPARED BY D. L. DICKENSON SURVEYOR _ 'LEGEND --- - - - - - - --- PROPERTY LINE, -'- ----------- � E------ PROPER LIN SETBACKS = - E — --E -- E -- UNDERGROUND ELECTRIC SERVICE - No.) DESCRIPTION DATE Ss ss —SS ss — SANITARY SEWER REVISIONS ' i ';; -' - -, "' - - I =ul tllliulN iilemG, ki IIIIIIIY,d,l lm lrlli ,lil , uru IYIIUIl1u YYIIINIIawIu.Ih WIIVn ill,,ilh,hu Ju ule� W —w w w WATER SERVICE - ' J,I�hdal aliadmlY'III 1' uhnhM1ddlll'Vlllhdh 11 llmhio1111V1YY,IWYiih',u lhd,IJtlYluihdktltlall l'W' E/P EDGE OF PAVEMENT W o /y N a = —GAS---GAS--- GAS cns-- UNDERGROUND GAS SERVICE ' ` U Z W za - tn w _- [ w UJ 4 w O SITE DATA < _J _- I y Q _ a 0 U_ `` ow - C PROPERTY ZONING CLASSIFICATION: DR 1 = z z = > MINIMUM LOT SIZE: 1 ACRE _ o z MINIMUM LOT WIDTH: 100 FEET J o . Q f 0 x0d 0w � - TAX� MAP NUMBER: 296.19-1-17.1 & 2 96.19-1-1, � �� _ � _ N o 0 0 0 CO - 0 a � i - I - - - - - - - - - - -o SETBACKS �� D� _Jz — - - - - - - - FRO:�IT �, REQUIRED EXISTING = U) = L w z n r© > > z —j- _ o a Y _ I SHORELINE �) 5,_�„� NA1 e W U `t o n v ” z W SIDE, 25'-0»J 38'-2" (� x`I t Q Q - � � max ° - 62 REAL: �0'-0» 217'-9» � ° N � �' o o E ` MAX BUILDING HEIGHT22#-O#$± y 40 0 MINF'AUM PERCENT PERMEABLE 7% 90.01% ACTIJAL LOT SIZE: 2.08 ACRES WORK IS TO BE AS SHOWN & - ACTUAL FRONTAGE: 275 FEET NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE EXISTING SITE COVERAGE CONDITIONS. ASSOCIATION PUBLISHED } COMPONENT . AREA PERCENTAGE RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL TOTAL SITE = CONSTRUCTION INDUSTRY i 30,06O5SFSF 13{ 0.�a F BUILDINGS PRACTICES. Lands N/F of O'Connor (3677/52) G PAVING & WALKS 5,848 SF 6.45% ' F1 I GREEN SPACE 8j 552 SF - --I- 90 J , � YYY , I -: - u w.JhhYlYinItYYYYe11ul.°• .,•••..• .F I i I I � aAM � s I I ' r Barn , , 4- 38 --2» � � ; 10" s ace — T fair t- F a) ��_< ., 2 w. pine � - Ion Pipe Foun _ I I – ---- Paved Parking) paved drive �— " ® I I I 12+ I _ Barn ayb SWAWNAY i North Country lit FN Z r62'- r I - 'r� *v t w. Iti3 DORI V�I JJ OR ��!¢ i"f'i Tt1✓i{ YY } t _ arborvitae hedge `o VoOrge orviv � � �.J°;4r E• {f ��k{IOC �1r� ItSSI WALKER lo vv I2oU A TREES AND SHRUBS TO BE RalOVED p`• p I �� --- � � - �t}��#Ii Animal Hosptalr.- AS INDICAITD �� i � 1 „ i is cif .lt t a —4— FINISHED FLOOR ELEV. iQ(�.Q �I JJ f Li;� (ASSUMED) ¢ �I u 1i°r'Park y r7 } t Q, S ' / 12" fir ----- ---- i ti tk4 rn l� � 11 Ine r Landing of 1 s ruc ruse 12" fir :; i. r --------------- ai,Eifiif `I, a !I P ., �� P j., ,,,r�, ( j i " 1 £CIPt7�rt t; Ado I {WVO�'' IkIO RTH $f1 ( 1 4 / '.)I'M,, t.l , r•`. �), !•1"" a L'�I-y l". T Y ft'°'lnl. tl { 12 sprat ! RE F`rz�1��j$ 4 I �/n Ii�FAI�i i F ,i1 L ow,esu`" r , pv d PROJECT LOCATION �` `� 2 ?. '9 I'm / fir v � _,,., � !'�' � I I r \ 0+ �'� t � 3`ID1�Q; "r ` Pond l _ I w... _ PG:ie ••4� "a f e1= t :-S r ,` �'S ( •^"�,�}q ti �. t'�.�' e y.,, 1"L3r1+( J ,',-.',t7`Di'dti tom. J .?i�_.- _"------- / =r l t g ' jl - YIt 47 i - ,.. rJ d If"a - s 24" maple r-- , , By y6,. ap. aple �' � a .... ,a`?a'as:.y' "'` :-��.;,f�:�z . �t �A,n`�.. �-��• �; Yf`,°c'�rljf�t`C1f"C'f' `` F�;'s�p'� _ . �� ivj C I' , /''y ti�. '•,-.Queenw bury jar .., plaza OR tksJl't�6C�Y'9�).]✓, _ Lit Y .,P;�xa Industi 4 3 Park Glen . — + I 1 �V + 'FuaRIIA ce icy gc Via{, It51� FOAM INSULATION MU8T Ll �,�„ maple COVERED YA `I5 MINUTE �`��! 20" maple "i. THERMAL " �`' '� �`� ,.r�-•� (�'� �+ + + --- - - - - - - - -- AL BARRIER .. _ ,:-: �����i _ - .�_ ..J�....../`..,../ `v-w "^^'' `o 4." - - _ _ ___ - - __ -_ t — - <4 - .•'vim+ A�:. .'�.' `Fi Ii1`v^' m �'?3 O_ - a\1�- wi!�' Yrs - ;,. Iron e Found �3 Pip d : . .. + - 1 2017 F° — - - - - - - �=_= )F QUEENSL --PROJECT LOCATION COMMUNITYL) V�'_O, ° Ven U � . SOP 0 SCALc Glenwood t �CACILE NAME Wv REV �QAD6\0C0NN0R\C-1 SITE PLAN IS v_____ _ — � � _ � - - -. � ._ - - _. — _ I }SCA LE _._. — — —. —. TOWN OF aE Aft MENT H.�...,;,,..,�,v.,w, ..,,_,,.,.• — — — — ` — �� � BUILDING PL SEAL BELOW IS AN ORIGINAL SEAL � DRAWN BY Based on our limited examination,compliance AND IS IN RED INK. ONLY SEALS IN RED INK with our comments shall not be construed as SHALL BE CONSIDERED TRUE ORIGINALS indicating the plans aild specifications are in DRAWING TITLE NOTICE: � , s � full compliance with iiie Building Codes of Smoke detectors are required in bedrooms, New York State. 9g SITE PLAN adjacent to bedrooms and on each floor ` `" level including cellar or basement. , .� � W EXISTING 1" = 30'-0» All smoke detectors & carbon monoxide � t �,, �� detectors shall be Interconnnected with " , battery t�aukup and lova? cin all levels. ' �� .y SITE PLAN ITOWN Car n monoxide cieteotorulred t .?our are re ' vuts�8e sleeping areas an on all levelsg �� q; I ' ,. 13y _+,l' ?J '.:::r,.'✓'t aa9g'ce'� r^?` - . D 1, g DRAWING No. i Q ' liudlll , ill hhun ldII bel l�l'IIV:ddVlnldld llleuduulu udll llll,lnu1 N - V) GENERAL NOTES INFORMATION SHORN ON THIS DRAWING IS TAKEN FROM - N A SURVEY DRAWING PREPARED BY D. L. DICKENSON SURVEYOR C - m LEGEND PROPERTY LINE = = r ------------------ PROPERTY LINE SETBACKS - CV Ln —E E —E --- E — UNDERGROUND ELECTRIC SERVICE - No.1 DESCRIPTION DATE00 REVISIONS -----SSSS —� —SS SANITARY SEWER - - Q d 16.o tl d l lllldll m I. II II V,tlll,l III II,I ILI lull,I. d IIIuII,I I,Ild'lld! IIYI III„,■ d -- w —w +r —w WATER SERVICE — 11 d.16,41 hI a tll,ln;Vit I. I IIII II I dlLl„hr Cy ' Q0 Y E/P , EDGE OF PAVEMENT W = 0 � � _ —cAs—c --- GAs— UNDERGROUND GAS SERVICE