Loading...
RC-000450-2017 40110k TOWN OF QUEENSBURY 1 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000450-2017 Date Issued: Monday, July 30, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000450-2017 has been completed. Tax Map Number: 308.20-1-31 Location: 41 DIVISION RD Owner: Josh Fish, Theresa Fish Applicant: Josh Fish This structure may be occupied as a: Residential Addition 1031 s.f. Residential Alteration 432 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000450-2017 Tax Map No: 308.20-1-31 Permission is hereby granted to: Honey-Do Man LLC For property located at: 41 DIVISION RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Josh Fish Single Family-Addition $46,400.00 Owner Address: 16 Sunnyside E Total Value $46,400.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Honey-Do Man LLC 442 CORINTH RD Queensbury,NY 12804 Plans&Specifications Residential Addition 1031 s.f. Residential Alteration 432 s.f. $271.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,September 12,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eensb ,7jltesd er 12,2017 SIGNED BY: �d for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only ADDITION/ALTERATION PERMIT Permit#: APPLICATION Permit Fee:$ ? ron'n of Queemsburti 742 Bay Road,Queensbury,NY 12804 JULInvoice#: p2d v P:518-761-8256 www.gueensbury.net U2 6 Lou Project Location: Ll 1 —biy 15w-N QJ Tax Map ID #: 3027. 2-0 - 1 -31 Subdivision Name: CONTACT INFORMATION: • Applicant: Name(s): jZd �►-/{ Jl �1 Mailing Address, C/S/Z: Cell Phone: ( 51% ) - c'13q Q Land Line: � ) Email: Primary Owner(s): Name(s): $G �1 Mailing Address, C/S/ . Cell Phone: ( 518 ) tgg3 Land Line: � ) Email: • Contractor(s): Business Name: KVb A&A LI- Contact Name(s): KV-01t.1 "roC1G£$. Mailing Address, C/S/Z: 4AL Coa_xolllrh Rd Qz6,► WV 11" Cell Phone: ( 511, ) 2loa -N1b1D Land One: � ) E ma i I:— �No n#-m•ckn.jan R h\ #Act l•tor& • Architect(s)/Engineer(s): Business Name: kL14� v A Contact Name(s): cc., Mailing Address, C/S/Z: 2Z pct lri,j L0 Dg. r4' fid, d �y IaLI Cell Phone: (( 51b �- 5gtos Land Line: _L Email: Contact Person for Building & Code Compliance:�j�Viwl Cell Phone: « ) WoO - 4910 Land Line: � ) Email: -- (�p,,,JIG��o �,�.,.•Cdw1� Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial J\ Residential WORK CLASS: Single-Family _Two-Family _ Multi-Family (#of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (# of cars ) _Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: o Jk 1st floor:_ -zi 2nd floor: 2nd floor: 3rd floor: 3rd floor: 4t'floor: 41h floor: Total square feet: 65� Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ (y,�w 2. If Commercial project, what is the proposed use: 3. Source of Heat (circle one): Gas OilPropan Solar Other Fireplaces need a separate Fuel Burning App iances& Chimney Application 4. Are there any structures not shown on the plot plan? YES N Explain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the arcel? b. Is this a corner lot? YES NO c. Will the grade be changed as a resul f t e construction? YES N d. What is the water source? PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? 'V#1 C' Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If thework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: V 1-14 (1 U(_ Q_ SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 REScheck Software Version 4.6.2 Compliance Certificate Project josh Fish JUL 2 8 7017 Energy Code: 2015 (ECIC Location: Warren County, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,115 ft2 Glazing Area 11% Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 41 division queensbury,NY 12804 - x Compliance 0.8%Better Than Code Maximum UA: 245 Your UA: 243 The%Better or worse Than code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling 1: Raised or Energy Truss 2,115 49.0 0.0 0.020 42 Wall 1: Wood Frame, 16" o.c. 1,116 21.0 0.0 0.057 64 684 15.0 0.0 0.077 34 Wail 2:Wood Frame, 16" o.c. 165 0.280 46 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 20 0.170 3 Door 1: Solid 40 0.300 12 Door 2:Glass 20 0.260 5 Door 3:Solid Basement Wail 1: Masonry Block with Empty Cells 518 0.0 15.0 0.045 23 Wall height: 7.0' Depth below grade: 6.5' Insulation depth: 7.0' Crawl 1: Masonry Block with Empty Cells 496 0.0 15.0 0.055 14 Wall height: 5.0' Depth below grade:4.5' Insulation depth: 5.0' 308.20-1-31 RC-000450-2017 Fish, Theresa & Josh 41 Division Road Res. Add. 1031 s.f., Res. Alt. 432 s.f. Report date: 07/19/17 Project Title:Josh Fish Page 1 of 10 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations has been designed to meet the 2015 IECC REScheck Version i4.6 2 andtt e comply withl,the'mandatory proposed building permit requi emet requirements in listed in the R Scheck Inspection Checklist. Name-Title Signature Date i r ' Report date: 07/19/17 Project Title:josh Fish Data filename: C:\Users\kevin\Documents\REScheckljosh fish.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not JPR111 energy code compliance for the ❑Not Observable building envelope.Thermal envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ElComplies 103.2, documentation demonstrate []Does Not '403.71 energy code compliance for Not Observable JPR31lighting and mechanical systems. Systems serving multiple []Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. i302.1, Heating and cooling equipment is Heating: Heating: ❑Complies ,403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not =[PR2J2 on loads calculated per ACCA Cooling: Cooling: []Not Observable I Manual J or other methods Btu/hr Btu/hr approved by the code official. E]Not Applicable i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 3 of 10 Section Plans Verified Field Verified j # Foundation Inspection Complies? Comments/Assumptions i & Req.ID Value Value --- -- -- --- - --- - - --- -- . ---- — — - - - — _......----- 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope assemblies [F0411 insulation R-value.Where interior R- R_ ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies (F05]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values, distance from top of wall. ❑Nat Observable , ❑Not Applicable 402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies able or values. j jF07]1 insulation R-value. R_ R_ ❑Does Not tfl , ❑Not Observable ❑Not Applicable 303.2 Unvented crawl space wall ❑Complies [FOB)' insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 1 402.2.11 Unvented crawl space continuous ❑Complies [FO9]1 vapor retarder installed over ❑Does Not exposed earth,joints overlapped by 6 in.and sealed, extending at ❑Not Observable least 6 in. up and attached to the []Not Applicable wall. 402.2.11 Unvented crawl space wall _in. in. ❑Complies See the Envelope Assemblies [FO10]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. i ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 j Low Impact(Tier 3) Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 4 of10 Section j plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID --- - -------- -- --- - --'-- -- -- ------ -- - - -- __._._.._. ._ - ------------- 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable - --- - --- -- - 402.1.1, Glazing U-factor(area-weighted U U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, [:]Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 1402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. []Not Observable []Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm leakage at 75 Pa. ❑Not Observable []Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where< 3 inches.Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated>=R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R R- ❑Complies [FR17]2 above 105 QF or chilled fluids []Does Not below 55 QF are insulated to>_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Com lies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable - ---- -- -- ---- --- - - -- - - .. ..- --- -- -------------------.. 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR1812 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)--_ Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 6 of 10 I Section # Insulation Inspection Plane Verified Field Verified Complies? Comments/Assumptions '303,1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 11402.1.1, Wail insulation R-value. if this is a R-_ R- ❑Complies See the Envelope Assemblies 1402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. ;402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable I[IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable i 1303.2 Wall insulation is installed per ❑Complies JIN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 7 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.iD - - 1 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.6 ❑ Steel ❑ Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. []Does Not { [F12]1 Blown insulation marked every 300 ftp. []Not Observable ❑Not Applicable f 402.2.3 Vented attics with air permeable []Complies [F122]2 insulation include baffle adjacent []Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies } [F13]1 insulation >_R-value of the []Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50- ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies (F14]1 cfm/100 ft2 across the system or ftz ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in []Not Observable tests,verification may need to []Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies j [FI27]1 determine air leakage with ft2 ft2 []Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handier enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differentia{of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies j [F[24]1 by manufacturer at<=2%of ❑Does Not design air flow. EINot Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. []Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI 10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies (FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions l I& Req.ID 403.6.1 All mechanical ventilation system ❑Complies (FI25J2 fans not part of tested and-listed- listed oes Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water j]Not Observable temperature based on outdoor []Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The []Does Not system return pipe is a dedicated return pipe or a cold water supply []Not Observable pipe. Gravity and thermos- ❑Not Applicable syphoncirculationsystems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems i_IComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the [:]Not Observable heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F13012 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated []Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F1611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F12313 no continuous pilot light. ❑Does Not ❑Not Observable []Not Applicable -1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 Low Impact(Tier 3)--A Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 9 of 10 (Section T Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req ID 401.3 Compliance certificate posted. ❑Complies i[F17]2 ❑Does Not []Not Observable ❑Not Applicable 1303.3 Manufacturer manuals for ❑Complies i[FI1813 mechanical and water heating ❑Does Not i systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:josh Fish Report date: 07/19/17 Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 10 of 10 Efficiency G"e ' 1` i ate Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling 1 Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.28 Door 0.30 Heating Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments Page 1 Residential Heat Loss and Heat Gain Calculation 8/15/2017 In accordance with ACCA Manual J Report Prepared By: Security Supply Corporation For: JOSH FISH 41 DIVISION RD QUEENSBURY, N.Y. 12804 Design Conditions: QUEENSBURY Indoor: Outdoor: Summer temperature: 70 Summer temperature: 92 Winter temperature: 72 Winter temperature: -15 Relative humidity: 55 Summer grains of moisture: 93 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 2,786.8 sq.ft. 23,757 4,505 28,262 72,597 2.5 tons First Floor21,931 4,504 26,435 64,644 ---------- __ - - _ BEDROOM 3 139 sq.ft. 2,715 535 3,250 8,643 Infiltration 577 535 1,112 3,991 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 139 sq.ft. 0 0 0 1,887 -Over unheated basement; Hardwood or tile; No insulation W Wall 77.7 sq.ft. 119 0 119 406 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 1,092 0 1,092 719 - Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. S Wall 73 sq.ft. 112 0 112 381 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 582 0 582 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. N Wall 43.3 sq.ft. 67 0 67 226 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 139 sq.ft. 166 0 166 314 - Under ventilated attic; R-38 (10 inch); Dark BEDROOM 3 wic 35 sq.ft. 103 0103 763 __...------ -- _ .. _--- Infiltration 0 0 0 0 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 35 sq.ft. 0 0 0 475 -Over unheated basement; Hardwood or tile; No insulation Page 2 JOSH FISH 8/15/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) S Wall 40 sq.ft. 61 0 61 209 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 35 sq.ft. 42 0 42 79 - Under ventilated attic; R-38(10 inch); Dark Bathroom 63 sq.ft. 186 0 186 1,374 Infiltration 0 0 0 0 -Tightness:Avg.; WinterACH: .7 ; SummerACH: .4 Floor 63 sq.ft. 0 0 0 855 -Over unheated basement; Hardwood or tile; No insulation S Wall 72 sq.ft. 111 0 111 376 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 63 sq.ft. 75 0 75 143 -Under ventilated attic; R-38(10 inch); Dark Bedroom 2 121 sq.ft. 2,620 535 3,155 8,107 Infiltration 577 535 1,112 3,991 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 121 sq.ft. 0 0 0 1,642 -Over unheated basement; Hardwood or tile; No insulation S Wall 73 sq.ft. 112 0 112 381 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 582 0 582 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. E Wall 73 sq.ft. 112 0 112 381 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 1,092 0 1,092 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading Ceiling 121 sq.ft. 145 0 145 274 - Under ventilated attic; R-38 (10 inch); Dark 1/2 BATH 48 sq.ft. 1,512 267 1,779 3,731 Infiltration 288 267 555 1,996 -Tightness:Avg.; WinterACH: .7 ; SummerACH: .4 Floor 48 sq.ft. 0 0 0 651 -Over unheated basement; Hardwood or tile; No insulation W Wall 49 sq.ft. 75 0 75 256 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 1,092 0 1,092 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 48 sq.ft. 57 0 57 109 -Under ventilated attic; R-38 (10 inch); Dark KITCHEN -- DINING 366 sq.ft. 8,029 1,777 9,806 12,792 Page 3 JOSH FISH 8/15/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Infiltration 1,173 1,087 2,260 8,115 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 People 3 900 690 1,590 0 Miscellaneous 1,200 0 1,200 0 Floor 366.3 sq.ft. 0 0 0 829 -Over enclosed crawl space; Hardwood or tile; R-19 (4 -6.5 inch) E Wall 183.2 sq.ft. 281 0 281 956 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none - - -- - - - ---- --- - --- --- —- ------ -- Window 9 sq.ft. 655 0 655 431 - Double pane; Wood frame; Clear glass - No inside shading; Coating: None(clear glass); No outside shading. Window(2) 10 sq.ft. 728 0 728 479 -Double pane; Wood frame; Clear glass - No inside shading; Coating: None(clear glass); No outside shading. Glassdoor 42 sq.ft. 2,705 0 2,705 1,250 - French doors; Double pane; Wood or vinyl frame; Low emittance - No inside shading; Coating: None(clear glass); No outside shading. Ceiling 366 sq.ft. 387 0 387 732 -Under ventilated attic;R-44 (14 inch); Dark Living Room 435 sq.ft. 2,047 267 2,314 10,194 Infiltration 288 267 555 1,996 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 435 sq.ft. 0 0 0 5,904 -Over unheated basement; Hardwood or tile; No insulation W Wall 135 sq.ft. 207 0 207 705 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none - - - ---- - - ----- - - Window 15 sq.ft. 1,092 0 1,092 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Ceiling 435 sq.ft. 460 0 460 870 -Under ventilated attic; R-44 (14 inch); Dark MUD ROOM 90 sq.ft. 1,038 321 1,359 4,663 Infiltration 346 321 667 2,395 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 90 sq.ft. 83 0 83 407 -Over garage or open crawl space; Hardwood or tile; R-19 (4-6.5 inch) W Wall 54 sq.ft. 83 0 83 282 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Door 18 sq.ft. 217 0 217 736 -Metal; Polystyrene; No storm _.---_._ .-- S Wall 112 sq.ft. 172 0 172 585 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none Ceiling 90 sq.ft. 137 0 137 258 Page 4 JOSH FISH 8/15/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) - Under ventilated attic; R-30 (8-9 inch); Dark master bedroom 390 sq.ft. 2,285 535 2,820 8,987 Infiltration 577 535 1,112 3,991 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 389.5 sq.ft. 0 0 0 881 -Over enclosed crawl space; Hardwood or tile; R-19 (4-6.5 inch) N Wall 179 sq.ft. 275 0 275 934 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none Window 15 sq.ft. 357 0 357 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. Window(2) 15 sq.ft. 357 0 357 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating None(clear glass), No outside shading. W Wall 180 sq.ft. 253 0 253 861 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board _ _ __--- _ ---- --- .. ---- --- --— --- ---- ---- Ceiling 390 sq.ft. 466 0 466 882 -Under ventilated attic; R-38 (10 inch); Dark master bath 132 sq.ft. 1,086 267 1,353 4,275 Infiltration 288 267 555 1,996 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 132 sq.ft. 0 0 0 299 -Over enclosed crawl space; Hardwood or tile; R-19 (4-6.5 inch) N Wall 93 sq.ft. 131 0 131 445 -Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board Window 15 sq.ft. 357 0 357 719 -Double pane; Wood frame; Clear glass -No inside shading; Coating: None(clear glass); No outside shading. — E Wall 108 sq.ft. 152 0 152 517 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board Ceiling 132 sq.ft. 158 0 158 299 - Under ventilated attic; R-38 (10 inch); Dark wic 132 sq.ft. 310 0 310 1,115 Infiltration 0 0 0 0 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 132 sq.ft. 0 0 0 299 -Over enclosed crawl space; Hardwood or tile; R-19(4 -6.5 inch) E Wall 108 sq.ft. 152 0 152 517 -Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board Ceiling 132 sq.ft. 158 0 158 299 -Under ventilated attic; R-38 (10 inch); Dark Basement 1,826 0 1,826 7,954 Page 5 JOSH FISH 8/15/2017 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Basement 836 sq.ft. 1,826 0 1,826 7,954 Infiltration 0 0 0 0 -Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4 Floor 836 sq.ft. 0 0 0 1,746 - Basement floor, 2'or more below grade; Concrete; Not applicable E Wall 342 sq.ft. 700 0 700 2,380 -Wood frame, with sheathing, siding or brick; R-13 4 in.; none W Wall 342 sq.ft. 700 0 700 2,380 -Wood frame,with sheathing, siding or brick; R-13 4 in.; none S Wall 208 sq.ft. 426 0 426 1,448 -Wood frame, with sheathing, siding or brick; R-13 4 in.; none Whole House 2,786.8 sq.ft. 23,757 4,505 28,262 72,597 2.5 tons HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.