RC-000450-2017 40110k
TOWN OF QUEENSBURY
1 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000450-2017 Date Issued: Monday, July 30, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000450-2017
has been completed.
Tax Map Number: 308.20-1-31
Location: 41 DIVISION RD
Owner: Josh Fish, Theresa Fish
Applicant: Josh Fish
This structure may be occupied as a: Residential Addition 1031 s.f.
Residential Alteration 432 s.f. By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000450-2017
Tax Map No: 308.20-1-31
Permission is hereby granted to: Honey-Do Man LLC
For property located at: 41 DIVISION RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: Josh Fish Single Family-Addition $46,400.00
Owner Address: 16 Sunnyside E Total Value $46,400.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Honey-Do Man LLC
442 CORINTH RD
Queensbury,NY 12804
Plans&Specifications
Residential Addition 1031 s.f.
Residential Alteration 432 s.f.
$271.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,September 12,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of eensb ,7jltesd er 12,2017
SIGNED BY: �d for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
ADDITION/ALTERATION PERMIT Permit#:
APPLICATION Permit Fee:$ ?
ron'n of Queemsburti
742 Bay Road,Queensbury,NY 12804 JULInvoice#: p2d v
P:518-761-8256 www.gueensbury.net U2 6 Lou
Project Location: Ll 1 —biy 15w-N QJ
Tax Map ID #: 3027. 2-0 - 1 -31 Subdivision Name:
CONTACT INFORMATION:
• Applicant:
Name(s): jZd �►-/{ Jl �1
Mailing Address, C/S/Z:
Cell Phone: ( 51% ) - c'13q Q Land Line: � )
Email:
Primary Owner(s):
Name(s): $G �1
Mailing Address, C/S/ .
Cell Phone: ( 518 ) tgg3 Land Line: � )
Email:
• Contractor(s):
Business Name: KVb A&A LI-
Contact Name(s): KV-01t.1 "roC1G£$.
Mailing Address, C/S/Z: 4AL Coa_xolllrh Rd Qz6,► WV 11"
Cell Phone: ( 511, ) 2loa -N1b1D Land One: � )
E ma i I:— �No n#-m•ckn.jan R h\ #Act l•tor&
• Architect(s)/Engineer(s):
Business Name: kL14� v A
Contact Name(s): cc.,
Mailing Address, C/S/Z: 2Z pct lri,j L0 Dg. r4' fid, d �y IaLI
Cell Phone: (( 51b �- 5gtos Land Line: _L
Email:
Contact Person for Building & Code Compliance:�j�Viwl
Cell Phone: « ) WoO - 4910 Land Line: � )
Email:
-- (�p,,,JIG��o �,�.,.•Cdw1�
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
PROJECT INFORMATION:
TYPE: Commercial J\ Residential
WORK CLASS:
Single-Family _Two-Family _ Multi-Family (#of units )
Townhouse Business Office Retail
Industrial/Warehouse _Garage (# of cars ) _Other (describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: o Jk 1st floor:_ -zi
2nd floor: 2nd floor:
3rd floor: 3rd floor:
4t'floor: 41h floor:
Total square feet: 65� Total square feet:
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ (y,�w
2. If Commercial project, what is the proposed use:
3. Source of Heat (circle one): Gas OilPropan Solar Other
Fireplaces need a separate Fuel Burning App iances& Chimney Application
4. Are there any structures not shown on the plot plan? YES N Explain:
5. Are there any easements on the property? YES NO
6. SITE INFORMATION:
a. What is the dimensions or acreage of the arcel?
b. Is this a corner lot? YES NO
c. Will the grade be changed as a resul f t e construction? YES N
d. What is the water source? PRIVATE WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? 'V#1 C'
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
DECLARATION:
1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If thework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: V 1-14 (1 U(_ Q_
SIGNATURE: DATE:
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
REScheck Software Version 4.6.2
Compliance Certificate
Project josh Fish JUL 2 8 7017
Energy Code: 2015 (ECIC
Location: Warren County, New York
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 2,115 ft2
Glazing Area 11%
Climate Zone: 6 (8499 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
41 division
queensbury,NY 12804
- x
Compliance 0.8%Better Than Code Maximum UA: 245 Your UA: 243
The%Better or worse Than code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Perimeter
Ceiling 1: Raised or Energy Truss 2,115 49.0 0.0 0.020 42
Wall 1: Wood Frame, 16" o.c. 1,116 21.0 0.0 0.057 64
684 15.0 0.0 0.077 34
Wail 2:Wood Frame, 16" o.c.
165 0.280 46
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E
20 0.170 3
Door 1: Solid
40 0.300 12
Door 2:Glass
20 0.260 5
Door 3:Solid
Basement Wail 1: Masonry Block with Empty Cells 518 0.0 15.0 0.045 23
Wall height: 7.0'
Depth below grade: 6.5'
Insulation depth: 7.0'
Crawl 1: Masonry Block with Empty Cells 496 0.0 15.0 0.055 14
Wall height: 5.0'
Depth below grade:4.5'
Insulation depth: 5.0'
308.20-1-31 RC-000450-2017
Fish, Theresa & Josh
41 Division Road
Res. Add. 1031 s.f., Res. Alt. 432 s.f.
Report date: 07/19/17
Project Title:Josh Fish
Page 1 of 10
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations has been designed to meet the 2015 IECC
REScheck Version i4.6 2 andtt e comply withl,the'mandatory proposed building
permit requi emet requirements in
listed in the R Scheck Inspection Checklist.
Name-Title
Signature Date
i
r '
Report date: 07/19/17
Project Title:josh Fish
Data filename: C:\Users\kevin\Documents\REScheckljosh fish.rck Page 2 of 10
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plans Verified Field Verified
# Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
JPR111 energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ElComplies
103.2, documentation demonstrate []Does Not
'403.71 energy code compliance for Not Observable
JPR31lighting and mechanical systems.
Systems serving multiple []Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
i302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
,403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
=[PR2J2 on loads calculated per ACCA Cooling: Cooling: []Not Observable
I Manual J or other methods Btu/hr Btu/hr
approved by the code official. E]Not Applicable
i
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:Josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 3 of 10
Section Plans Verified Field Verified j
# Foundation Inspection Complies? Comments/Assumptions i
& Req.ID Value Value
--- -- -- --- - --- - - --- -- . ---- — — - - - — _......-----
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope assemblies
[F0411 insulation R-value.Where interior R- R_ ❑Does Not table for values.
insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
(F05]1 insulation installed per ❑Does Not
manufacturer's instructions.
❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06]1 insulation depth of burial or ❑Does Not table for values,
distance from top of wall.
❑Nat Observable ,
❑Not Applicable
402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies
able or values.
j
jF07]1 insulation R-value. R_ R_ ❑Does Not tfl ,
❑Not Observable
❑Not Applicable
303.2 Unvented crawl space wall ❑Complies
[FOB)' insulation installed per ❑Does Not
manufacturer's instructions.
❑Not Observable
❑Not Applicable 1
402.2.11 Unvented crawl space continuous ❑Complies
[FO9]1 vapor retarder installed over ❑Does Not
exposed earth,joints overlapped
by 6 in.and sealed, extending at ❑Not Observable
least 6 in. up and attached to the []Not Applicable
wall.
402.2.11 Unvented crawl space wall _in. in. ❑Complies See the Envelope Assemblies
[FO10]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall. i
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 j Low Impact(Tier 3)
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 4 of10
Section j plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
--- - -------- -- --- - --'-- -- -- ------ -- - - -- __._._.._. ._ - -------------
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
- --- - --- -- -
402.1.1, Glazing U-factor(area-weighted U U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, [:]Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
1402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
[]Not Observable
[]Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate<_2.0 cfm
leakage at 75 Pa. ❑Not Observable
[]Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where< 3 inches.Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated>=R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R R- ❑Complies
[FR17]2 above 105 QF or chilled fluids []Does Not
below 55 QF are insulated to>_R-
❑
3 Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Com lies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
- ---- -- -- ---- --- - - -- - - .. ..- --- -- -------------------..
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR1812 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)--_
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 5 of10
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 6 of 10
I Section
# Insulation Inspection Plane Verified Field Verified Complies? Comments/Assumptions
'303,1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
11402.1.1, Wail insulation R-value. if this is a R-_ R- ❑Complies See the Envelope Assemblies
1402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
;402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
I[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
i
1303.2 Wall insulation is installed per ❑Complies
JIN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:Josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 7 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.iD - - 1
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2,
402.2.6 ❑ Steel ❑ Steel ❑Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. []Does Not {
[F12]1 Blown insulation marked every
300 ftp. []Not Observable
❑Not Applicable f
402.2.3 Vented attics with air permeable []Complies
[F122]2 insulation include baffle adjacent []Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies }
[F13]1 insulation >_R-value of the []Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50- ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
(F14]1 cfm/100 ft2 across the system or ftz ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in []Not Observable
tests,verification may need to []Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies j
[FI27]1 determine air leakage with ft2 ft2 []Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handier
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differentia{of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies j
[F[24]1 by manufacturer at<=2%of ❑Does Not
design air flow.
EINot Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. []Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI 10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
(FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 8 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions l
I& Req.ID
403.6.1 All mechanical ventilation system ❑Complies
(FI25J2 fans not part of tested and-listed-
listed oes Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water j]Not Observable
temperature based on outdoor []Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[FI28]2 have a circulation pump.The []Does Not
system return pipe is a dedicated
return pipe or a cold water supply []Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphoncirculationsystems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems i_IComplies
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the [:]Not Observable
heat tracing to maintain the []Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[F13012 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated []Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F1611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F12313 no continuous pilot light. ❑Does Not
❑Not Observable
[]Not Applicable
-1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 Low Impact(Tier 3)--A
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 9 of 10
(Section T Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req ID
401.3 Compliance certificate posted. ❑Complies
i[F17]2 ❑Does Not
[]Not Observable
❑Not Applicable
1303.3 Manufacturer manuals for ❑Complies
i[FI1813 mechanical and water heating ❑Does Not
i systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:josh Fish Report date: 07/19/17
Data filename: C:\Users\kevin\Documents\REScheck\josh fish.rck Page 10 of 10
Efficiency G"e ' 1` i ate
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling 1 Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.28
Door 0.30
Heating Cooling
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
Page 1 Residential Heat Loss and Heat Gain Calculation 8/15/2017
In accordance with ACCA Manual J
Report Prepared By:
Security Supply Corporation
For: JOSH FISH
41 DIVISION RD
QUEENSBURY, N.Y. 12804
Design Conditions: QUEENSBURY
Indoor: Outdoor:
Summer temperature: 70 Summer temperature: 92
Winter temperature: 72 Winter temperature: -15
Relative humidity: 55 Summer grains of moisture: 93
Daily temperature range:Medium
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
Whole House 2,786.8 sq.ft. 23,757 4,505 28,262 72,597
2.5 tons
First Floor21,931 4,504 26,435 64,644
---------- __ - - _
BEDROOM 3 139 sq.ft. 2,715 535 3,250 8,643
Infiltration 577 535 1,112 3,991
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 139 sq.ft. 0 0 0 1,887
-Over unheated basement; Hardwood or tile; No insulation
W Wall 77.7 sq.ft. 119 0 119 406
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 1,092 0 1,092 719
- Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
S Wall 73 sq.ft. 112 0 112 381
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 582 0 582 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
N Wall 43.3 sq.ft. 67 0 67 226
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none
Ceiling 139 sq.ft. 166 0 166 314
- Under ventilated attic; R-38 (10 inch); Dark
BEDROOM 3 wic 35 sq.ft. 103 0103 763
__...------ -- _ .. _---
Infiltration 0 0 0 0
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 35 sq.ft. 0 0 0 475
-Over unheated basement; Hardwood or tile; No insulation
Page 2 JOSH FISH 8/15/2017
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
S Wall 40 sq.ft. 61 0 61 209
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Ceiling 35 sq.ft. 42 0 42 79
- Under ventilated attic; R-38(10 inch); Dark
Bathroom 63 sq.ft. 186 0 186 1,374
Infiltration 0 0 0 0
-Tightness:Avg.; WinterACH: .7 ; SummerACH: .4
Floor 63 sq.ft. 0 0 0 855
-Over unheated basement; Hardwood or tile; No insulation
S Wall 72 sq.ft. 111 0 111 376
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none
Ceiling 63 sq.ft. 75 0 75 143
-Under ventilated attic; R-38(10 inch); Dark
Bedroom 2 121 sq.ft. 2,620 535 3,155 8,107
Infiltration 577 535 1,112 3,991
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 121 sq.ft. 0 0 0 1,642
-Over unheated basement; Hardwood or tile; No insulation
S Wall 73 sq.ft. 112 0 112 381
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 582 0 582 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
E Wall 73 sq.ft. 112 0 112 381
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 1,092 0 1,092 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading
Ceiling 121 sq.ft. 145 0 145 274
- Under ventilated attic; R-38 (10 inch); Dark
1/2 BATH 48 sq.ft. 1,512 267 1,779 3,731
Infiltration 288 267 555 1,996
-Tightness:Avg.; WinterACH: .7 ; SummerACH: .4
Floor 48 sq.ft. 0 0 0 651
-Over unheated basement; Hardwood or tile; No insulation
W Wall 49 sq.ft. 75 0 75 256
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 1,092 0 1,092 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
Ceiling 48 sq.ft. 57 0 57 109
-Under ventilated attic; R-38 (10 inch); Dark
KITCHEN -- DINING 366 sq.ft. 8,029 1,777 9,806 12,792
Page 3 JOSH FISH 8/15/2017
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
Infiltration 1,173 1,087 2,260 8,115
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
People 3 900 690 1,590 0
Miscellaneous 1,200 0 1,200 0
Floor 366.3 sq.ft. 0 0 0 829
-Over enclosed crawl space; Hardwood or tile; R-19 (4 -6.5 inch)
E Wall 183.2 sq.ft. 281 0 281 956
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
- - -- - - - ---- --- - --- --- —- ------ --
Window 9 sq.ft. 655 0 655 431
- Double pane; Wood frame; Clear glass
- No inside shading; Coating: None(clear glass); No outside shading.
Window(2) 10 sq.ft. 728 0 728 479
-Double pane; Wood frame; Clear glass
- No inside shading; Coating: None(clear glass); No outside shading.
Glassdoor 42 sq.ft. 2,705 0 2,705 1,250
- French doors; Double pane; Wood or vinyl frame; Low emittance
- No inside shading; Coating: None(clear glass); No outside shading.
Ceiling 366 sq.ft. 387 0 387 732
-Under ventilated attic;R-44 (14 inch); Dark
Living Room 435 sq.ft. 2,047 267 2,314 10,194
Infiltration 288 267 555 1,996
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 435 sq.ft. 0 0 0 5,904
-Over unheated basement; Hardwood or tile; No insulation
W Wall 135 sq.ft. 207 0 207 705
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
- - - ---- - - ----- - -
Window 15 sq.ft. 1,092 0 1,092 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
Ceiling 435 sq.ft. 460 0 460 870
-Under ventilated attic; R-44 (14 inch); Dark
MUD ROOM 90 sq.ft. 1,038 321 1,359 4,663
Infiltration 346 321 667 2,395
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 90 sq.ft. 83 0 83 407
-Over garage or open crawl space; Hardwood or tile; R-19 (4-6.5 inch)
W Wall 54 sq.ft. 83 0 83 282
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Door 18 sq.ft. 217 0 217 736
-Metal; Polystyrene; No storm
_.---_._ .--
S Wall 112 sq.ft. 172 0 172 585
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; none
Ceiling 90 sq.ft. 137 0 137 258
Page 4 JOSH FISH 8/15/2017
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
- Under ventilated attic; R-30 (8-9 inch); Dark
master bedroom 390 sq.ft. 2,285 535 2,820 8,987
Infiltration 577 535 1,112 3,991
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 389.5 sq.ft. 0 0 0 881
-Over enclosed crawl space; Hardwood or tile; R-19 (4-6.5 inch)
N Wall 179 sq.ft. 275 0 275 934
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; none
Window 15 sq.ft. 357 0 357 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading.
Window(2) 15 sq.ft. 357 0 357 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating None(clear glass), No outside shading.
W Wall 180 sq.ft. 253 0 253 861
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board
_ _ __--- _ ---- --- .. ---- --- --— --- ---- ----
Ceiling 390 sq.ft. 466 0 466 882
-Under ventilated attic; R-38 (10 inch); Dark
master bath 132 sq.ft. 1,086 267 1,353 4,275
Infiltration 288 267 555 1,996
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 132 sq.ft. 0 0 0 299
-Over enclosed crawl space; Hardwood or tile; R-19 (4-6.5 inch)
N Wall 93 sq.ft. 131 0 131 445
-Wood frame,with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board
Window 15 sq.ft. 357 0 357 719
-Double pane; Wood frame; Clear glass
-No inside shading; Coating: None(clear glass); No outside shading. —
E Wall 108 sq.ft. 152 0 152 517
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board
Ceiling 132 sq.ft. 158 0 158 299
- Under ventilated attic; R-38 (10 inch); Dark
wic 132 sq.ft. 310 0 310 1,115
Infiltration 0 0 0 0
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 132 sq.ft. 0 0 0 299
-Over enclosed crawl space; Hardwood or tile; R-19(4 -6.5 inch)
E Wall 108 sq.ft. 152 0 152 517
-Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-1.8 1/2 in. Bead board
Ceiling 132 sq.ft. 158 0 158 299
-Under ventilated attic; R-38 (10 inch); Dark
Basement 1,826 0 1,826 7,954
Page 5 JOSH FISH 8/15/2017
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
Basement 836 sq.ft. 1,826 0 1,826 7,954
Infiltration 0 0 0 0
-Tightness:Avg.; Winter ACH: .7 ; Summer ACH: .4
Floor 836 sq.ft. 0 0 0 1,746
- Basement floor, 2'or more below grade; Concrete; Not applicable
E Wall 342 sq.ft. 700 0 700 2,380
-Wood frame, with sheathing, siding or brick; R-13 4 in.; none
W Wall 342 sq.ft. 700 0 700 2,380
-Wood frame,with sheathing, siding or brick; R-13 4 in.; none
S Wall 208 sq.ft. 426 0 426 1,448
-Wood frame, with sheathing, siding or brick; R-13 4 in.; none
Whole House 2,786.8 sq.ft. 23,757 4,505 28,262 72,597
2.5 tons
HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101
Load calculations are estimates only,actual loads may vary due to weather and construction differences.