Loading...
scan008APPROXIMATE FINISH GRADE MINIMUM 2X WIDTH MAXIMUM 4X WIDTH POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER SUGGESTED: INSTALL POLYLOK PL -122 FILTER SUCH THAT IT IS READILY REMOVABLE THROUGH TANK ACCESS COVER DISTRIBUTION BOX 4" PVC SDR -35 OUTLET MIN. SLOPE 1/8" PER FOOT BAFFLE- . 1 USE SPEED LEVELERS TO ASSURE-` ALL OUTLETS ARE AT EXACTLY / THE SAME ELEVATION 4" PVC SDR -35 SOLID HEADER TO PERFORATED TRENCH PIPING, 1/8" PER FOOT MIN SLOPE I d 6 SEPTIC TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE, SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING. SEPTIC TANK DETAIL N TS NEW HYDRANT ASSEMBi VILLAGE WATER DEPAF STANDARD AND THE 10 RECOMMENDED STANDARI WATER HYDRANT DRIP PLUG SEASONAL HIGH GROUNDWA SHALLOWER THAN HYDRANTS WITH PLUGGED HOLES SHALL BE TAGGED I BRASS TAG INDICATING HOLE IS PLU 12" MIN. y 2' IN PAVED AREAS: SAW CUT PAVEMENT ANG MAX. ; REPLACE WITH: COVER 4" PVC SDR -35 ° RESTORE TURF AFTER 2,, INLET TURF MIN. SLOPE ° LIQUID LEVEL 1/4" PER FOOT 2" MIN, ° 16" 18„ MIRAFI 140N OR EQUIVALENT MIN, WATERTIGHT SLEEVE -- I I I-1 I I-1 I i=1 I II i LEI I 5E1 11= AND SEAL (TYP) d OaJ` .1 EXCAVATE TRENCH WIDTH Q o' PROPOSED 1250 GAL— AL 4' MAX. PRECAST PRECAST CONCRETE -�!! SEPTIC TANK I MINIMUM 2X WIDTH MAXIMUM 4X WIDTH POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER SUGGESTED: INSTALL POLYLOK PL -122 FILTER SUCH THAT IT IS READILY REMOVABLE THROUGH TANK ACCESS COVER DISTRIBUTION BOX 4" PVC SDR -35 OUTLET MIN. SLOPE 1/8" PER FOOT BAFFLE- . 1 USE SPEED LEVELERS TO ASSURE-` ALL OUTLETS ARE AT EXACTLY / THE SAME ELEVATION 4" PVC SDR -35 SOLID HEADER TO PERFORATED TRENCH PIPING, 1/8" PER FOOT MIN SLOPE I d 6 SEPTIC TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE, SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING. SEPTIC TANK DETAIL N TS NEW HYDRANT ASSEMBi VILLAGE WATER DEPAF STANDARD AND THE 10 RECOMMENDED STANDARI WATER HYDRANT DRIP PLUG SEASONAL HIGH GROUNDWA SHALLOWER THAN HYDRANTS WITH PLUGGED HOLES SHALL BE TAGGED I BRASS TAG INDICATING HOLE IS PLU 3/4" TO 1 1/2" WASHED CRUSHED STONE 2" MIN. DROP BETWEEN INVERTS 12" MIN. COVER 4" MIN TOPSOIL OVER THE 171RE ABSORPTION FIELD; SEED & ESTABLISH TURF GRANULAR BACKFILL FREE OF STONES OVER 2" FILTER FABRIC MIRAFI 140N OR EQUAL 2' TRENCH WIDTH 2" MIN. 2" 0n OVERFILL TO ALLOW FOf SETTLEMENT 6-12" 1C)12" MIN. 6 o��DDJ v o DO 3/4" TO 1-1/2" WASHED CRUSHED STONE ABSORPTION TRENCH SECTION DE NTS y 2' IN PAVED AREAS: SAW CUT PAVEMENT ANG MAX. ; REPLACE WITH: IDE AT UNPAVED AREAS, 12" MAX THE ENTIRE ABSORPTION FIELD; RESTORE TURF AFTER 2" NYSDOT ITEM 403.13 BINDER SEED AND ESTABLISH TURF i ADJUSTABLE VALVE FILTER FABRIC 2" MIN, i`' BOX MIRAFI 140N OR EQUIVALENT 12" NYSDOT I I I-1 I I-1 I i=1 I II i LEI I 5E1 11= d OaJ` .1 EXCAVATE TRENCH WIDTH 3/4" TO 1 1/2" WASHED CRUSHED STONE 2" MIN. DROP BETWEEN INVERTS 12" MIN. COVER 4" MIN TOPSOIL OVER THE 171RE ABSORPTION FIELD; SEED & ESTABLISH TURF GRANULAR BACKFILL FREE OF STONES OVER 2" FILTER FABRIC MIRAFI 140N OR EQUAL 2' TRENCH WIDTH 2" MIN. 2" 0n OVERFILL TO ALLOW FOf SETTLEMENT 6-12" 1C)12" MIN. 6 o��DDJ v o DO 3/4" TO 1-1/2" WASHED CRUSHED STONE ABSORPTION TRENCH SECTION DE NTS y 2' IN PAVED AREAS: SAW CUT PAVEMENT ANG MAX. ; REPLACE WITH: IDE AT UNPAVED AREAS, 4" MIN TOPSOIL OVER THE ENTIRE ABSORPTION FIELD; RESTORE TURF AFTER 2" NYSDOT ITEM 403.13 BINDER SEED AND ESTABLISH TURF i ADJUSTABLE VALVE FILTER FABRIC 5' MIN. COVER BOX MIRAFI 140N OR EQUIVALENT 12" NYSDOT I I I-1 I I-1 I i=1 I II i LEI I 5E1 11= ITEM 304.05 (ITEM-4)`� VARIES EXCAVATE TRENCH WIDTH 6" MIN. 4' MAX. SLOPE —� 00M00��, , M.J. GATE VALVE 5' MIN. 4" PERFORATED PVC LATERAL, MACHINE BACKFILL W/NATIVE MATERIAL COVER \ `•, \` SLOPE 1/16" - 1/32" PER FT. END CAP NOTE. CONNECTION TO BE COMPLETED IN ACCORDANCE WITH TOWN OF EXISTING MAIN \-NEW TAPPING QUEENSBURY WATER DEPARTMENT SLEEVE STANDARDS BY AN APPROVED SELECT GRANULAR MATERIAL (100% CONTRACTOR ABSORPTION TRENCH PROFILE PASSING 2") TO 18" ABOVE PIPE, CONNECTION TO EXISTING WATER MAIN DETAIL NTS NTS BEDDING 6" DEPTH; SAND, GRAVEL OR /—CRUSHED STONE (1-1/2" MAX) FIRE HYDRANT INSTALLATION DETAIL N TS 2' MAX. y 2' IN PAVED AREAS: SAW CUT PAVEMENT ANG MAX. ; REPLACE WITH: IDE AT UNPAVED AREAS, 12 NYSDOT ITEM 304.05 (ITEM -4) RESTORE TURF AFTER 2" NYSDOT ITEM 403.13 BINDER I EXCAVATION � 1.5" NYSDOT ITEM 403.16 TOPCOAT 12" NYSDOT ITEM 304.05 (ITEM-4)`� EXCAVATE TRENCH WIDTH TO PIPE WIDTH PLUS 2' MIN. 5' MIN. ` MACHINE BACKFILL W/NATIVE MATERIAL COVER \ `•, \` (4" MAX. SIZE); COMPACT IN 12" LIFTS SELECT GRANULAR MATERIAL (100% PASSING 2") TO 18" ABOVE PIPE, HAND BACKFILL IN 6" LIFTS ' KO BEDDING 6" DEPTH; SAND, GRAVEL OR /—CRUSHED STONE (1-1/2" MAX) PIPE---- PIPE IPESPIPE EXCAVATION & BACKFILL DETAIL NTS CONCR! BEARING AREA ON UNDISTURBED EARTH BEARING AREA \-CONCRETE NOTE: PROVIDE 6 SF BEARING AREA AGAINST UNDISTURBED EARTH; (6 & 8" PIPE, 2000 PSI SOIL BEARING) WATER MAIN THRUST BLOCKS DETAIL FILED Warren County Clerk September 11, 2017 Instrument No. 2017-3000081 UL.MMrvv rirNz^ NTS FINISHED GRADE CORPORATION STOP 5' MIN. 15' COPPER TUBING (TYPE K) BLOCK &6 -OF NS \" ONS r � 1" IN GRASS AREAS; FLUSH WITH PAVEMENT CURB BOX (EXTENSION TYPE WITH ARCH PATTERN BASE AND STA77ONARY ROD) CURB STOP TYPE K COPPER PIPE TO BUILDING \_6" D.I.P. WATER MAIN SOLID CONC, BLOCK OR C.I. NOTE: ALL WATER PIPING & CONNECTIONS TO BE FOOT PIECE AS REQUIRED IN ACCORDANCE WITH QUEENSBURY WATER DEPARTMENT STANDARDS WATER SERVICE PIPE CONNECTION DETAIL NTS NEW YORK STATE DEPARTMENT OF HEALTH Glens Fails District Office Refer to first sheet for approved date and signature. WASTEWATER SYSTEM DESIGN 4 -BEDROOM RESIDENCE WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 440 GPD SEPTIC TANK - 1250 GALLON PRECAST CONCRETE SEPTIC TANK LEACH FIELD - STANDARD PIPE -IN -STONE TRENCHES IN AMENDED SOILS DESIGN PERCOLATION RATE IN NATIVE MATERIAL= 1-5 MIN/IN ABSORPTION APPLICATION RATE = 1.2 GPD/SF ABSORPTION TRENCH AREA REQUIRED = 367 SF ABSORPTION TRENCH LENGTH REQUIRED = 184 LF INSTALL (4) TRENCHES AT 50' EACH, 200 LF TO BE PROVIDED - POTABLE WATER SUPPLY TO BE ON-SITE WELL MAINTAIN 50' SETBACK TO SEPTIC TANK MAINTAIN 100' SETBACK TO ABSORPTION FIELD & STORMWATER INFILTRATION DEVICES AMENDED SOILS NOTES REMOVE ALL SOIL BOUNDED BY 2 -FEET FROM THE PROPOSED ABSORPTIO TRENCHES (I.E. HORIZONTALLY AND VERTICALLY) AND BLEND WITH SAND LOAM MATERIAL, REPLACE MATERIAL IN 6 -INCH LIFTS WITH MECHANICA COMPACTION TO THE APPROXIMATE DENSITY OF THE ON-SITE SOIL. TH BLENDED SOIL IN-PLACE PERCOLATION RATE MUST BE 2-5 MINUTE PE INCH, AND PERCOLATION TESTS MUST BE CONDUCTED BY THE DESIG ENGINEER PRIOR TO TRENCH CONSTRUCTION. CONSTRUCT CONVENTIONAL ABSORPTION TRENCHES IN THE BLENDED SOh IF AMENDED SOILS PERCOLATION RATE IS NOT 2-5 MIN. PER INCL INSTALLER SHALL COMPLETELY REMOVE ALL AMENDED SOIL AND RE -GLEN AND REPLACE. REPLACEMENT GRANULAR SOIL WITH A PERCOLATION RATE OF 2 - MINUTES PER INCH RANGE MAY BE USED TO FILL THE EXCAVATION 1 PLACE OF BLENDED SOIL. ALL OTHER CONDITIONS NOTED ABOVE SHALL B MET. SYSTEM INSTALLATION NOTES L,U1V3/KUU 11V/V )rlALL tit AS SHOWN ON THIS DRAWING AND IN ACCORDANCE MT THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTI F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTI1 TANK LEACH FIELDS. AFTER EXCAVATION OF TRENCHES TO THE DEPTHS REQUIRED, THE WALLS ANI FLOOR OF EACH TRENCH SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEI SMEARED SECTIONS OF TRENCH, PLACEMENT OF WASHED CRUSHED STONE, PERFORATED PIPE AND FILTER FABRR SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION 01 FINE GRAINED SOILS AND WASTE MATERIAL IN THE PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHEI UNSUITABLE CONDITIONS. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HA: BEEN INSTALLED. THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNEL TO ACCOMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICE SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. INSTALLER ADVISED TO CONTACT DIG SAFELY NEW YORK PRIOR TC CONSTRUCTION. ASTEWATER SYSTEM MATERIAL SPECIFICATIONS HOUSE SEWER PIPING TO BE 4" SDR -35 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE EFFLUENT SEWER PIPING TO BE 4" SDR -35 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE X ABSORPTION TRENCH PERFORATED PIPE w PIPING TO BE 4" PERFORATED PVC WASHED STONE STONE IS TO BE 3/4" TO 1-1/2" WASHED STONE FILTER FABRIC FILTER FABRIC TO BE TENCATE MIRAFI 140N OR EQUIVALENT 4 OZ/SY MINIMUM BACKFILL MATERIAL BACKFILL TO BE GRANULAR BACKFILL MATERIAL WITH NO PARTICLES GREATER THAN 3" TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF TAX MAP # 308.18-1-1 ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. 5 REVISED PER DOH COMMENTS - RE -ISSUED TO NYSDOH 8/10/1; 4 ADDED APPROVAL RESOLUTIONS - ISSUED TO NYSDOH 4/11 /1 3 ISSUED FOR PRELIMINARY & FINAL SUBDIVISION 9/15/1( 1 ISSUED FOR PRELIMINARY SUBDIVISION & AREA VARIANCE 2/16/1; No. Revisions Date WATER & WASTEWATER DETAILS prepared for., Maurice H. Combs 636 Corinth Road Town of Queensbury, Warren County, NY Drown: LWD Checked: GTH Scale: NOTED Date: 10/8/14 169 Hoviland Road Queensbury, NY 12804 29832-01 _�� Hutchins Engineering (518) 745-0307 Phone jf 518 745-0308 Fax