Loading...
RC-000562-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000562-2017 Tax Map No: 296.14-2-18 Permission is hereby granted to: CERRONE BUILDERS,INC. For property located at: 16 DEVIN CT In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvoe of Construction Owner Name: CERRONE BUILDERS,INC. Single Family-New $363,000.00 Owner Address: 1589 State Route 9 Total Value $363,000.00 Fort Edward,NY 12828 Contractor or Builder's Name/Address Electrical Inspection Agency CERRONE BUILDERS,INC. 1589 State Route 9 Fort Edward,NY 12828 Plans&Specifications Single Family Dweeling w/FP 1563 s.f. Garage 400 s.f. Village at Sweet Road,Lot 18 $1,272.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,September 19,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of ueensb ues Se e 19,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PKlINCIPAL N'1'K U' 'UKL APPLICAl'IVIN Office Use Only Date: Permit No. Tax Map ID Permit Fee rwo-i uJ Zone Historic? _Yes No Rec Fee g 50 22 Subdivision NameLot#1/ Site Plan# Subdivision# Project Location J TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) ;� J Address 4---)/ /, / Phone/Email �L /(/ �r Applicant Address f F . , �s Phone/Email S Contractor 1 -e;,,-• gra( r .... .....,.ri Address Owl '. Phone/Email Contact Person for Building & Codes Compliance: Phone f s TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1St floor sf 2°a floor sf Total sf Height Single Family Two-Family / U Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory- Industrial Attached Garage / (1(93, 4+)2, Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? Yes No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well (circle one) Pu is Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed (labor or materials) $ 30 �1l� DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: /C> --� - DATE: SIGNATURE: ADATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel'Burning Appliance & Chimney Application Office Use Only Received DATE: Tax Map ID TAX MAP ID: Permit No. Permit Fee ZONE: OWNER e I J PHONE/E-MAIL ADDRESS INSTALLER/ PHONE/E-MAIL BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL BUILDING ADDRESS ROOM OF INSTALL: L// �� /I - PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: 71G ; Model#: / Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL T IPLE WALL INSULATED ** If non-masonry provide manufacturer name: 10ff i ; Model#: (� DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: �II7 PRINT NAME: DATE: W1 SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Vara Ness Highway Department highway Superintendent 742 Bay Road, Queensbury, Nei' 12804 Dome: 518•-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duel! Deputy highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: ' J f; Applicant Name: p _ 5AI L— ` Telephone No.: Address to be Inspected A' ° ' Return Address: Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED O Slight Swale ( ) Deep Swale ( ) Level with the road SEP 0 b 2011 O Level with the top of the paved wing Size culvert pipe to be used (if necessary) -___•.mu. ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Manual S Compliance Report Job: 16 DEVIN CRT Date: Sep 01,2017 Entire House By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY, NY 12804 Project • • For: CERRONE, CERRONE BUILDERS QUEENSBURY, NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 18124 Btuh Entering coil DB: 75.5°F Outdoor design WB: 71.0°F Latent gain: 4808 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 22932 Btuh Indoor RH: 50% Estimated airflow: 985 cfm ES Manufacturer's Performance Data at Actual Design Conditions II Equipment type: Split AC SEP 0 b 2017 I { Manufacturer: Model: n.x. Actual airflow: 985 cfm �1WN CI=Q;;; ., ,�,0 �'3 ` Sensible capacity: 0 Btuh 0% of load SUNII.NING&(110 +.- Latent capacity: 0 Btuh 0% of load " Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 75568 Btuh Entering coil DB: 64.5°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Model: Actual airflow: 985 cfm Output capacity: 0 Btuh 0% of load Temp. rise: 0 °F 296.14-2-18 RC-000562-2017 Cerrone Builders 16 Devin Court, Lot 18 Meets are all requirements ofACCA Manual S. SFD W/FP 1563 S.f., Garage 400 s.f. wrightsoft® 2017-Sep-01 14:37:16 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACOA ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N '`- Form Aill Residential Plans Form RIPER 1 �Ck• • System — •n (Loads, Equipment, 15 Mar 09 n:c«,aaa Cmbam afkmw QUEENSBURY NY 12804 Header Information Contractor: CERRONE BUILDERS REQUIRED ATTACHMENTS ATTACHED Manual J 1 Form(and supporting worksheets): Yes E] No E] Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes F-i No F-1 OEM performance data(heating,cooling,blower): Yes No EJ Building plan#: 16 DEVIN Manual D Friction Rate Worksheet: Yes No M Home address(Street or Lot#, Block,Subdivision): , Entire House Duct distribution sketch: Yes 0 No E] HVAC LOAD CALCULATION • 1 Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: Front Door faces North Indoor temperature: 68 of North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 75568 Btuh Number of bedrooms: 0 Conditioned floor area: 4620 ftZ Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof gain:Grains difference: 28 gr/Ib 50% RH Eave overhang depth: 0 ft Sensible heat 9 20138 Btuh Internal shade: none Eave Latent heat gain: 5342 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 25480 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment tye: Gas furnace Equipment type: SplitAC Heating cfm: 985 umace,Heatpump,Boiler,etc. AirConditioner,Heat pump,etc. Cooling cfm: 9855 Model: Model: Static pressure: 0 in H2O + Fan's rated external static pressure for Heating output capacity:. 0 Btuh Total cooling capacity: 0 Btuh designairflow Heat pumps-capacity atwmterdesignoutdoor conditions Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh DISTRIBUTIONIHVAC DUCT •1 Design airflow: 985 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: o in/100ft Branch duct: Sheet metal Friction Rate=ASP=(TEL x 100) 1 declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: MunicipalityReserved for County,Town 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist - wrightSOW Right-Suite®Universal 2017 17.0.16 RSU25116 Project Summa Job: 16 DEVIN CRT Date: Sep 01,2017 Enure House By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY, NY 12804 Promect Information For: CERRONE, CERRONE BUILDERS QUEENSBURY, NY 12804 Notes: Design Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 68 OF Inside db 75 OF Design TD 72 OF Design TD 10 OF Dallyrange M Reive Humidity 50 % Moisture difference 28 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 69635 Btuh Structure 17053 Btuh Ducts 5933 Btuh Ducts 1071 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 75568 Btuh Use manufacturer's data in Rate/swing multiplier 0.90 Infiltration Equipment sensible load 16312 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 1 (Average) Structure 2957 Btuh Ducts 1850 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft') 4620 4620 Equipment latent load 4807 Btuh Volume ft' ) 41580 41580 Air changes/hour 0.46 0.23 Equipment total load 21119 Btuh Equiv.AVF (cfm) 318 159 Req. total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 700 Btuh/ft Total cooling 0.054 cfm/Btuh Total low baseboard 108 ft Actual air flow 0 in H2O High output baseboard Air flow factor 0.79 Total high baseboard Static pressure Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoftw 2017-Sep-01 14:37:16 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ..ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N AED Assessment Job: 16 DEVIN CRT Date: Sep 01,2017 Entire House By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY, NY 12804 Project • • For: CERRONE, CERRONE BUILDERS QUEENSBURY, NY 12804 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 68 75 Elevation: 335 ft Design TD (°F) 72 10 Latitude: 43°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 48.0 27.6 Dry bulb (°F) -4 85 Infiltration: Daily range (°F) - 20 ( M ) Wet bulb (°F) - 71 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Hourly Glazing Load 3,500-- 3,000-- 2,500-- 2.000 ,5003,0002,5002,000 0 m N l0 1,500- 1,000-- 500-- 0 ,5001,0005000 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day /Hourly /Average /AED limit Maximum hourly glazing load exceeds average by 50.7%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 458 Btuh (PFG - 1.3*AFG) 2017-Sep-01 14:37:16 wrightsoft' Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACOA ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Right-J®Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 BSCOTT LANGWORTHY CERRONE BUILDERS Pran: 16 DEVIN QUEENSBURY, NY 12804 1 Room name Entire House Room2 2 Exposed wall 540.0 ft 182.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1550.0 ft 5 Room area 4620.0 ftz 1550.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft2°F) (BtuWft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 1350 1350 8845 2027 450 450 2948 676 W 12C-0sw 0.091 a 6.55 1.50 1080 1065 6978 1599 369 354 2319 532 I-- G 1D-c2ov 0.570 e 41.04 58.17 15 0 616 872 15 0 616 872 W 12C-Osw 0.091 s 6.55 1.50 1323 1323 8668 1986 450 450 2948 676 11 IW 12C-Osw 0.091 w 6.55 1.50 1107 1077 7057 1617 369 339 2221 509 L--G 1D-c2ov 0.570 w 41.04 58.17 30 0 1231 1745 30 0 1231 1745 C 166-30ad 0.032 - 2.30 1.44 3070 3070 7073 4421 0 0 0 0 F 19A-19bscp 0.049 2.76 0.38 1550 1550 4285 595 1550 1550 4285 595 6 c)AED excursion 458 458 Envelope loss/gain 44753 153211 16570 6063 12 a) Infiltration 24881 1732 8386 584 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 69635 17053 24955 6646 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 69635 17053 24955 6646 15 Duct loads 9% 6% 5933 1071 9% 6% 2126 417 Total room load 75568 18124 27082 7064 LowlHigh Baseboard/Cool Air 151 108 985 54 39 384 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 414- wri htsoft 2017-Sep-0114:37:16 .4G�A 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ..ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Right-J®Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY,NY 12804 1 Room name Room3 Room4 2 Exposed wall 182.0 ft 28.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 1550.0 ft 1.0 x 200.0 ft ft 5 Room area 1550.0 ' 200.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (13tuVft2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-0sw 0.091 n 6.55 1.50 450 450 2948 676 126 126 826 189 W 12C-0sw 0.091 a 6.55 1.50 369 369 2418 554 0 0 0 0 1 Dc2ov 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-0sw 0.091 s 6.55 1.50 450 450 2948 676 0 0 0 0 11 W 12C-0sw 0.091 w 6.55 1.50 369 369 2418 554 126 126 826 189 �� 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 2.30 1.44 1550 1550 3571 2232 200 200 461 288 F 19A-19bscp 0.049 - 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 14303 4691 2112 666 12 a) Infiltration 8386 584 1290 90 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 22689 5275 3402 756 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22689 5275 3402 756 r Duct loads 19% 6% 1933 331 9% 6% 290 47 Total room load 24623 5607 3692 804 LowlHigh Baseboard/Cool Air 491 35 1 305 7 5 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _411- wri htsoft- 2017-Sep-0114:37:16 9 Right-Suite®Universal 2017 17.0.16 RSU25116 ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Page 2 Right-J®Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 By SCOTT LANGWORTHY CERRONE BUILDERS Pfan: 16 DEVIN QUEENSBURY, NY 12804 1 Room name Room5 R0om7 2 Exposed wall 20.0 ft 63.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 10.0 x 10.0 ft 1.0 x 790.0 ft 5 Room area 100.0 ft2 790.0 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ftp) Load number (Btuh/ft2_°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 90 90 590 135 234 234 1533 351 IW 12C-Osw 0.091 a 6.55 1.50 90 90 590 135 72 72 472 108 �--G 1 Dc2ov 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 6.55 1.50 0 0 0 0 162 162 1061 243 11 VE— G 12C-0sw 0.091 w 6.55 1.50 0 0 0 0 99 99 649 149 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 166-30ad 0.032 2.30 1.44 100 100 230 144 790 790 1820 1138 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 1410 414 5535 1989 12 a) Infiltration 922 64 2903 202 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2331 478 8438 2191 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2331 478 8438 2191 15 Duct loads 9% 6% 199 30 9% 6% 719 138 Total room load 2530 508 9157 2329 LowlHigh Baseboard/Cool Air 5 4 28 18 13 127 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- wri F1tsOft 2017-Sep-0114:37:16 4C�A 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 ..ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Right-J®Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY,NY 12804 1 Room name Room8 Room9 2 Exposed wall 10.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 5.0 x 10.0 ft 2.0 x 6.0 ft 5 Room area 50.0 ft' 12.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh1ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (13t h) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 a 6.55 1.50 90 90 590 135 0 0 0 0 1 D-c2ov, 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 6.55 1.50 0 0 0 0 0 0 0 0 11 IWI - 12C-Osw 0.091 w 6.55 1.50 0 0 0 0 0 0 0 0 L--G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 2.30 1.44 50 50 115 72 12 12 28 17 F 19A-19bscp 0.049 - 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 705 207 28 17 12 a) Infiltration 461 32 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1166 239 28 17 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1166 239 28 17 15 Duct loads 9% 6% 99 15 9% 6% 2 1 Total room load 1265 25430 18 LowlHigh Baseboard/Cool Air 3 2 14 0 0 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. , A wright50ft" 2017-Sep-01 14: e 4 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Right-M Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY,NY 12804 1 Room name Room10 Room11 2 Exposed wall 0 ft 22.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 3.0 x 6.0 ft 12.0 x 10.0 ft ft 5 Room area 18.0 ' 120.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2°F) (13tuNft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 0 0 0 0 IW 12C-Osw 0.091 a 6.55 1.50 0 0 0 0 90 90 590 135 W--G 1 D-c2ov 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-0sw 0.091 s 6.55 1.50 0 0 0 0 108 108 708 162 11E12C-0sw 0.091 w 6.55 1.50 0 0 0 0 0 0 0 0 --G 1 Dc2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 166-30ad 0.032 2.30 1.44 18 18 41 26 120 120 276 173 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 41 26 1574 470 12 a) Infiltration 0 0 1014 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 41 26 2587 541 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 41 26 2587 541 15 Duct loads 9% 6% 4 2 9% 6% 220 34 Total room load 45 28 2808 575 LowlHigh Baseboard/Cool Air 0 0 1 6 4 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wri9 FltsOftRight-Suite®Universal 2017 17.0.16 RSU25116� 2017-Sep-0114:37:16 ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Page 5 Right-J® Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 SCOTT CERRONE BUILDERS Pfan: 16 DEVINANGWORTHY QUEENSBURY, NY 12804 1 Room name Room13 Room14 2 Exposed wall 7.0 ft 15.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 7.0 x 10.0 ft 10.0 x 5.0 ft 5 Room area 70.0 ft2 50.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2_°F) (Btuh/ft') or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 0 0 0 0 Wj 12C-Osw 0.091 e 6.55 1.50 0 0 0 0 0 0 0 0 �—G 1 D-c2ov 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 6.55 1.50 63 63 413 95 90 90 590 135 11 IW 12C-Osw 0.091 w 6.55 1.50 0 0 0 0 45 45 295 68 --G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 2.30 1.44 70 70 161 101 50 50 115 72 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 574 195 1000 275 12 a) Infiltration 323 22 691 48 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1 897 2181 1691 1323 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 897 218 1691 323 15 Duct loads 9% 6% 76 14 9% 6% 144 20 Total room load 973 232 1835 343 LowlHigh Baseboard/Cool Air 2 1 13 4 3 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrl htsoft, 2017-Sep-01 14:37:16 �A 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 6 ...ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N Right-J®Worksheet Job: 16 DEVIN CRT Entire House Date: Sep 01,2017 By: SCOTT LANGWORTHY CERRONE BUILDERS Plan: 16 DEVIN QUEENSBURY,NY 12804 1 Room name Room15 Room16 2 Exposed wall 4.0 ft 7.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 10.0 x 4.0 ft 10.0 x 7.0 ft 5 Room area 40.0 ft' 70.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (W) Load number (Btuh/ft'°F) (Btuh/ftz) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 0 0 0 0 12C-Osw 0.091 a 6.55 1.50 0 0 0 0 0 0 0 0 1L—G 1 D-c2ov 0.570 e 41.04 58.17 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 6.55 1.50 0 0 0 0 0 0 0 0 11VE 12C-Osw 0.091 w 6.55 1.50 36 36 236 54 63 63 413 95 1 Dc2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 166-30ad 0.032 2.30 1.44 40 40 92 58 70 70 161 101 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 328 112 574 195 12 a) Infiltration 184 13 323 22 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 512 124 897 218 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 512 124 897 218 r Duct loads 9% 6% 44 8 9% 6% 76 14 Total room load 556 132973 232 LowlHigh Baseboard/Cool Air 1 1 7 2 1 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoftm2017-Se -01 14:37:16 p .4CP Right-Suite®Universal 2017 17.0.16 RSU25116 Page 7 ..ott.langeworthy\Documents\York\16 DEVIN CRT.rup Calc=MJ8 Front Door faces: N RE c eck SoftwareVersion Compliance Certificate Project Cerrone Builders Incfi �- y fI Energy Code: 2015 IECC Location: Glens Falls, New York ES b � �� Construction Type: S Single-family �; J f y Project Type: New Construction _ Conditioned Floor Area: 1,563 ft2 a`�VV N OF 0UL�K� Glazing Area 15% 6 U ILDD N��a Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 16 Devin Court VISION Engineering, LLC Lot 18 206 Glen Street Queensbury, NY 12804 Suite 56 Glens Falls, NY 12801 « « :I"Bill « Compliance: 0.7%Better Than Code Maximum UA: 271 Your UA: 269 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Ceiling 1: Raised or Energy Truss 1,563 38.0 0.0 0.025 39 Floor 1: All-Wood Joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0 Wall 1: Wood Frame, 16" o.c. 1,683 21.0 0.0 0.057 80 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 196 0.290 57 Door 1: Solid 18 0.140 3 Door 2: Solid 20 0.200 4 Door 3: Glass 40 0.290 12 Basement Wall 1: Solid Concrete or Masonry 1,458 0.0 15.0 0.046 66 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2:Vinyl/Fiberglass Frame:Double Pane 7 0.400 3 Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 296.14-2-18 RC-000562-2017 Cerrone Builders 16 Devin Court, Lot 18 SFD W/FP 1563 s.f., Garage 400 s.f. Project Title: Cerrone Builders Inc Report date: 08/27/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1272 - DES - CER Page 1 of 10 16 Devin Crt Lot 18\1272 CER 16 Devin Crt Lot 18.rck RE t eck Software Ver . Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Se •tion Pians Verified Field Verified Pie-lnspecti©n/Pian ReYIeW Valu Vatue Complies? Comm nts/Assumptions 77 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. t ON .......,, 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [:]Not Observable [PR311 lighting and mechanical systems F rt, r Systems serving multiple r ❑Not Applicable dwelling units must demonstrate compliance with the IECC F' Commercial Provisions. F 30 Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 -sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not (FR' 1z on loads calculated per ACCA Cooling Cooling ❑Not Observable Manual J or other methods Btu/hrBtu/hr approved by the code official ❑Not Applicable Additional Comments/Assumptions: 1 High Impac J2, Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 08/27/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1272 - DES - CER Page 3 of 10 16 Devin Crt Lot 18\1272 CER 16 Devin Crt Lot 18.rck cin � PESlerlfc! Field Veriaett / h 1401Ia[u ValueComplies? € mtsfAs€ ti 402.1,1, Door U-factor. U- U- :❑Complies jSee the Envelope Assemblies 402.3.4 ;❑Does Not table for values. [FR1]1 ❑Not Observable ; ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted I U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ^❑Does Not ;table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 t 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ` taken from the default table. ❑Not Observable ❑Not Applicable ; 402.4.1.1 'Air barrier and thermal barrier ❑Complies ; [FR23]1 installed per manufacturer's ❑Does Not z instructions. ❑ Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not ,.4 :AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC .; ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. SIC-rated recessed lighting fixtures ❑Complies sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. -]Not Observable !s3 ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where< 3 inches. Supply and r ❑Not Observable i return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. _.......... 403.3.3.5 Building cavities are not used as ❑Complies [FR1513 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable , HVAC piping conveying fluids R- R- ❑Complies above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to >R- 3 ❑Not Observable ❑Not Applicable 403.4.1 �'Protection of insulation on HVAC � `�, ��" ' �❑Complies [FR24]1 piping. ❑Does Not []Not Observable c ❑Not Applicable 4031,53 Hot water pipes are insulated to R- R- ;❑Complies [FR1812 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable '61 Automatic or gravity dampers are _ ❑Complies ]2. installed on all outdoor air ,a❑Does Not intakes and exhausts. ❑Not Observable .F ❑Not Applicable 1 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 08/27/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1272 - DES -CER Page 5 of 10 16 Devin Crt Lot 18\1272 CER 16 Devin Crt Lot 18.rck # #nsulati�an•Ins Inspection _.Plans ValueVerified ... FieldDefied Complies? Comments/Assumptions•,_, _.. Section Eiexl.la, 3,01A . All installed insulation is labeled > ❑Complies RN1312 `or the installed R-values ❑Does Not provided. ❑Not Observable '1'11"11'111'1' 17", ❑Not Applicable 402.1.1, Floor insulation R value. R- R- ❑Complies ;See the Envelope Assemblies 402.2.6 ❑ Wood r-1Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable I , d 303.2, Floor insulation installed per ' El Complies -10 1402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the ❑Not Observable ( underside of the subfloor, or floor 'N framing cavity insulation is in � r � ❑Not Applicable N contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R value. If this is a R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not ;table for values. 402.2.6 wall insulation on the wall El mass E] Mass -]Not Observable [IN3]1 exterior,the exterior insulation requirement applies (FR10). E] Steel E] Steel ❑Not Applicable ..........._................ [303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ..*.._ = ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) z Medium Impact(Tier 2) " Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 08/27/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1272 - DES - CER Page 7 of 10 16 Devin Crt Lot 18\1272 CER 16 Devin Crt Lot 18.rck est o Plans Verified � FieldVerified Final Inspection Provisions Value Value Complies? C se is/Assumptions Rei ID 403.6,1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy -]Not Observable !and air flow limits. ❑Not Applicable Hot water boilers supplying heat ❑Complies F> ;through one-or two-pipe heating ❑Does Not " systems have outdoor setback „ ;control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. Heated water circulation systems ❑Complies 3 � < have a circulation pump.The iE.:', ❑Does Not system return pipe is a dedicated - -, ❑Not Observable return pipe or a cold water supplys y x pipe. Gravity and thermos- � � ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal Rg ;, ';for hot water demand within the ". � y�occupancy. Controls ��_� automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 4015.1.1 1., F' Electric heat trace systems ❑Complies [i=f9 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically ❑Not Observable i adjust the energy input to the heat tracing to maintain the ❑Not Applicable j desired water temperature in the piping. x Water distribution systems that "❑Complies have recirculation pumps that x ❑Does Not y pump water from a heated water supply pipe back to the heated -]Not Observable water source through a cold ❑Not Applicable water supply pipe have a F demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold i water piping to 1044F. 1403 4 LDrain water heat recovery units ❑Complies i[F13' tested in accordance with CSA []Does Not 1355.1. Potable water-side �, li2 •g pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for []Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water ' a ?heat recovery units< 2 psi for 1 individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies E [F16]1 fixtures or 75%of permanent ❑Does Not { fixtures have high efficacy lamps , Does not apply to low-voltage ❑Not Observable ❑Not Applicable lighting. 404.1.1 Fuel gas lighting systems have K ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable z. ❑Not Applicable 1 High Impact(Tier1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 08/27/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1272 - DES -CER Page 9 of 10 16 Devin Crt Lot 18\1272 CER 16 Devin Crt Lot 18.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Valuo Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHdC Window 0.29 Door 0.29 Cooling,Heating& . . Heating System: Cooling System: Water Heater: Name: Date: Comments v �• r � zA --zA — O N p N0 — �t O � O cQ co O L ca C9 i J to co co N 4 O N S' CO i 'p p N m P IT PLOT PLAN ALLY MEASURED THE DISTANCE FRO HE PROPERTY RUCTURE(S)OR I S SI TURE ATE Map Reference: The Village at Sweet Road Map of a Subdivision Plan made for Cerrone Builders Dated:February 05,2014 Last Revised:July 30,2014 By:Van Dusen&Steves Filed:September 30,2014 Lot 19 N 790 15 43"E 135.00 — Lot 18 0. Q,�\ cs Arc Length: 102.3 \ Area �..; M. oB ,. o \ 12897.0#Sq.Feet F Radius: 225.00 °s m4 - Chord Bearing: N 2 010°07"W ELectricMeter 0.3#Acres Chord Length: 101.4 Gas meter 1 Story \ Wood Frame Ronan House :. ,3Z 1'L 0 CO ►7 Lot 29 FEB 0 5 2018 TOWN OF QUEEt URY s 4t Ct3f-INIR9NITY DEV& fi�ENT -- - } end c,. .� WS =Water Shut Off }7: Q =Sanitary Sewer Access Cover i` __ ED Cable N 'Electric Box ,Do.ter January 30, 2018 S' Scale 1"=20` ..+/ 'UNAUTHORIZED ALTERATION OR ADDITION S A SURVEY Map Of a Survey Tilade for •�\V't MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A ^ VIOLATION OF SECTION 7209,SUB-DIVISION 2,OF THE C}(Xp, NEW YORK STATE EDUCATION LAW." 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY (� 1 - MARKED WITH AN.ORIGINAL OF THE LAND SURVEYORS _ - .L - SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.'Steves e r g o 11 e Builders _ 'CERTIFICATIONS INDICATEDHEREONSIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE - EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED - Lai d S iA r T-r /� '�"j® syr s _ BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL _ - L� - V C J`/ i LAND SURVEYORS SAID E ASS CATIONS SHALL RUN ONLY SHEET 1 OF 1 - - TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND _ ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL - - r�p/� AGENCY AND LENDING INSTITUTION LISTED HEREON,AND Town of Queensbury, Warren County, New York 169 Haviland Road Queensbury, New York 12804 TO THE ASSIGNEES OF THE LENDING INSTITUTION." G.NO. -247 Builders _ t18 ( ) • 0135 � LA0. DATE DESCRIPTION Owo.No.o5-2a7 Lo 518 792 8474 New York. Lic. No. 5 `