RC-000632-2017TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000632-2017 Tax Map No: 239.7-1-38 Permission is hereby granted to: Frank Perrotta,Jr. For property located at: 60 Knox RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Frank Perrotta,Jr. Single Family-New 1,200,000.00 Owner Address: 43 Talcott Range DR Total Value 1,200,000.00 East Granby,CT 06026 Contractor or Builder's Name/Address Electrical Inspection Agency Adirondack Project Consultants,LLC 1557 State Route 9,Suite 2 Lake George,NY 12845 Plans&Specifications Single Family Dwelling w/4 FPs 5717 s.f. Garage 1076 s.f. Bonus Room above Garage 980 s.f. 2,351.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,November 14,2018 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queeneueensb fore the ex . tion date.) Dated at the Town of 4 ues ember 14,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement I %PRINCIPAL STRUCTURE APPLICATION Office Use Only L 0 U 3 Date: August 2, 2017 Tax Ma239.7-1-38ID Permit No. yqc MapPermit Fee 1 .S 01 Zone WR Historic? _Yes X No Rec Fee SY6,L)o Subdivision Name Sunset Hill Farm Lot# a 3 `' L9-0 17 d i n1E Project Location 60 Knox Rd., Queensbury,NY 4 TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelli i slh fly2>`f lex s o family, multiple family, apartments,condominiums,townhouses,and/or manufactured&mo ular h —mes. his is in addition to the permit fee(s). TOWN OF QUEENSBURY Primary Owner(s) Frank Perrotta L—_ SUIlDING&CODES Address 43 Talcott Range Dr., East Granby, CT 06206 Phone/Email 860) 402-8937 Applicant Adirondack Project Consultants, LLC Address 1557 State Rt. 9 ( Suite 2 , Lake George, NY 12845 Phone/Email 518) 538-9450 adirondack.pc@gmail.com Contractor Adirondack Project Consultants,LLC Address 1557 State Rt. 9 , Suite 2,Lake George, NY 12845 Phone/Email 518) 538-9450 adirondack.pc@gmail.com Contact Person for Building&Codes Compliance: Stephen Adler Phone (518) 538-9450 TYPE OF CONSTRUCTION Check all that apply New Addition Mteration I"floor sf 2nd floor sf Total sf Height Lower Level Single Family X 2,384 s.f. 2,353 s.f 1,174 s.f. 5,717 s.f. 32' Two-Family Multi-Family of units_) Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage X 1,076 s.f. 1,076 s.f. 1, 2, 3, 4+) Other Bonus 980 s.f 980 s.f. Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use'of building or addition Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances& Chimneys Are there structures not shown on plot plan? No Are there easements on the property? kes Site Information: a. Dimensions or acreage of lot 5.6 Ac. +/- b. Is this a corner lot? Yes X No c. Will the grade be changed as a result of construction Yes X No d. Public water or Private well (circle one) Public JrivatDe e. Sewer or Private Septic System (circle one) Sewerrivat Value of all work to be performed(labor or materials) 1,200,000.00 DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Stephen W Adler DATE: 9/5/2017 SIGNATURE: St`2 12h GyD(GeY DATE: 9/5/2017 For office use only Operating Permit Issued:Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: 9/25/2017 Tax Map ID TAX MAP ID: 239.7-1-38 Permit No. ZONE: WR Permit Fee APPLICANT Adirondack Project Consultants, LLC PHONE/E-MAIL (518)538-9450 ADDRESS 1557 State Rt. 9, Lake George, NY 12845 INSTALLER/ Adirondack Industries Inc.PHONE/E-MAIL (518)538-9450 BUILDER OWNER Frank Perrotta ADDRESS 43 Talcott Range Dr., East Granby, Ct 06206 CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: _Dennis Macelroy PHONE/E-MAIL dmacelroy@edpllp.com RESIDENCE INFORMATION Year Built of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes _X No 1981-1991 Spa or Hot Tub installed _Yes X No 1992-Present 5 110/Gal/Bdrm/Day 550 PARCEL INFORMATION Topography X Flat rolling Steep slope Slope Soil Nature X Sand X Loam Clay Other Groundwater At what depth: None observed @ 54" Bedrock/Impervious material At what depth: None observed Domestic Water Supply Municipal X Well(if well,water supply from any septic system absorption is 120ft.) Percolation Test Rate: 20 per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size 1500 gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: EJEN- Concrete Sand Bed Per EDP Plan Holding Tank System Total required capacity?Tank size of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: Stephen W. Adler DATE: 9/5/2017 SIGNATURE: DATE: 9/5/2017 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 rull E Fuel Burning Appliance & Chimney Applicatione OnlDATE: 9/5/2017 IDTAxMAPID: 238.7-1-318 JSBU YZONE; WR iDES OWNER Frank Perrotta PHONE/E-MAIL 1 (860) 402-8937 ADDRESS 43 Talcott Range Dr., East Granby, CT 062016 INSTALLER/ Adirondack Project Consultants,LLC PHONE/E-MAIL (518) 538-9450 BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Stephen Adler PHONE/E-MAIL adirondack.pc@gmail.com BUILDING ADDRESS 60 Knox Rd yROOMOFINSTALL:Lower Level Famil Room PLANNED INSTALL DATE: Feb. 2018 FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT` NOTE. MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION If factory built provide manufacturer name: Heatilator Model#: NDV4842 Listed by: ANSI Z21.88b-2008 Number: UL307B CHIMNEY INFORMATION Masonry`* (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material X DOUBLE WALL TRIPLE WALL INSULATED If non-masonry provide manufacturer name: TBD Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: Stephen W Adler DATE: SIGNATURE: Stephen W. Aga- DATE: 9/5/2017 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 I Fuel,Burning Appliance & Chimney Application Office Use-Only Received DATE: 9/5/2017 Tax Map ID TAX MAP ID: 238.7-1-318 Permit No. ZONE: WR Permit Fee OWNER Frank Perrotta PHONE/E-MAIL 1 (860) 402-8937 ADDRESS 43 Talcott Range Dr., East Granby, CT 062016 INSTALLER/ Adirondack Project Consultants, LLC PHONE/E-MAIL (518) 538-9450 BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Step en Adler PHONE/E-MAIL adirondack.pc@gmail.com BUILDING ADDRESS 60 Knox Rd ROOM OF INSTALL: Lower Level Family Room PLANNED INSTALL DATE: Feb. 2018 FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT*NOTE: FIREPLACE,MASONRY MANUFACTURER'S INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION If factory built provide manufacturer name: Heatilator Model#: NDV4842 Listed by: ANSI Z21.88b-2008 Number: UL307B CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material X DOUBLE WALL TRIPLE WALL INSULATED If non-masonry provide manufacturer name: TBD Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: Stephen W Adler DATE: 9/5/2017 SIGNATURE: ste heh W. Aga- DATE: 9/5/2017 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 NATURAL LIGHT,VENTILATION AND EMERGENCY EGRESS CALCULATION SHEET Job Site Address: 60 Knox Rd. Queensbury,NY 12804 9/5/2017 weer: n U) Frank Perrotta I mW pati c1h.) wv C= 06 abi a le Area of Room-Sq.Ft. Required light Actual light-sq.ft. Required ventilation ActualVentilation sq.ft. Sq.Ft.opening for F- LL 0UOO 0 8%of room 4%of room egress m 820.49 65.6 95.1 32.8 74.5 e 283.7 22.7 38 11.3 19 20.25 L.L.ensuite Bath 94 7.5 6.28» 3.7 6.1 Theater 304 24.3 13.5» 12.2 8.6 Gym 206.3 16.5 8.2 L.L.Powder Rm. 60.2 4.8 2.4 Master Bed Rm. 504.2 40.3 88.9 20.2 33.6 24 Master Bath 175.8 14.1 22.4 7.1 10.7 Gr. Rm/Kit 804.2 64,3 244.9 32.2 66.1 Foyer/Dining 455.3 36.4 70.3 18.2 27.8 Laundry 69 5.5 2.8 Powder Rm. 19.5 1.5 78 Sunroom 330.8 26.5 198.3 13.2 49.8 Mechanical Light and Ventilation Per Code Section R303 to be Provided Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 NATURAL. LIGHT VENTILATION AND EMERGENCY EGRESS CALCULATION SHEET Job Site Address: 60 Knox Rd Date: 9/5/2017 Owner: Frank Perrotta Application No.: Habitable Rooms Area of Room-Sq. Ft. M Required light Actual light—sq. fl. Required ventilation ! Actual Ventilation sq. ft. Sq. Ft. opening for 8%of mom 4%of room egress Bonus Entry 128.7 10.3 38.5 5.1 6.5 Loft 406.2 ..__--- 32.5 33,4 16.2 13.6 Bedroom 2 254 20.3 26.9 10.2 14.4 7.1 Bed 2 Bath 75 6 3 Bedroom 3 286.4 23 49.3 11.5 36.8 7.1 Bed 3 Bath 61.8 4.9 2.5 Bonus Room 980 78.4 83.5 39.2 39.6 7.3 Mechanical Light and Ventilation Per Code Section R303 to be Provided Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 a NATURAL LIGHT,VENTILATION AND EMERGENCY EGRESS CALCULATION SHEET Job Site Address: 60 Knox Rd. Queensbury,NY 12804 Date: 9/5/2017 Frank Perrotta W 1 9 C IZID) ab to le Area of Room-Sq.Ft. Required light Actual light-sq.ft. Required ventilation Actual Ventilation sq.ft. Sq.Ft.opening forCM C= d Z 8%of room 4%of room egress F gy J 820.49 65,6 95.1 32.8 74.5 O 283.7 22.7 38 11.3 19 20.25 e Bath 94 7.5 6.28* 3.7 6.1 Theater 304 24.3 13.5* 12.2 8.6 Gym 206.3 16.5 8.2 L.L.Powder Rm. 60.2 4.8 2.4 Master Bed Rm. 504.2 40.3 88.9 20.2 33.6 24 Master Bath 175.8 14.1 22.4 7.1 10.7 Gr. Rm / Kit 804.2 64.3 244.9 32.2 66.1 Foyer/Dining 455.3 36.4 70.3 18.2 27.8 Laundry 69 5.5 2.8 Powder Rm. 19.5 1.5 78 Sunroom 330.8 26.5 1 1 i I I 198.3 13.2 49.8 Mechanical Light and Ventilation Per Code Section R303 to be Provided Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 NATURAL LIGHT,VENTILATION AND EMERGENCY EGRESS CALCULATION SHEET Job Site Address: 60 Knox Rd Date: 9/5/2017 Owner: Frank Perrotta Application No,: Habitable Rooms Area of Room-Sq.—H—_Required light Actual light—sq. A. Required ventilation Actual Ventilation sq. ft. Sq. Ft.opening for 8%of roorn 4%of room egress Bonus Entry 128.7 10.3 38.5 5.1 6.5 Loft 406.2 32.5 33.4 16.2 13.6 Bedroom 2 254 20.3 26.9 10.2 14.4 7.1 Bed 2 Bath 75 6 3 Bedroom 3 286.4 23 49.3 11.5 36.8 7.1 Bed 3 Bath 61.8 4.9 T * 2.5 Bonus Room 980 78.4 83.5 39.2 39.6 7.3 Mechanical Light and Ventilation Per Code Section R303 to be Provided Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 REScheck Software Version 4.6.2 V C D Compliance Certificate M tD i Q CU EGEOVE 0 Project Perrotta Residence CE 47 cn Energy Code: 2015 IECC r- Location: Warren County, New York JC P_Construction Type: Single-family CWNMcacnProjectType: New Construction L0 d Conditioned Floor Area: 6,891 ft2 M LCL W LL Glazing Area 15% tQ X tt r Climate Zone: 6 (8499 HDD) 3 Permit Date: i Y Permit Number: M d (D LL N d (fl 0 Construction Site: Owner/Agent: Designer/Contractor: 60 Knox Rd Stephen Adler Stephen Adler Queensbury, NY 12804 Eastern Adirondack Home& Adirondack Project Consultants,LLC Design, LLC 1557 State Rt.9 1557 State Rt.9 Suite 2 Suite 2 Lake George, NY 12845 Lake George,NY 12845 518) 538-9450 518)644-2328 adirondack.pc@gmail.com adirondack.pc@gmaii.com Compliance: Passes using UA trade-off Compliance: 6.7%Better Than Code Maximum UA: 863 Your UA: 805 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. it DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Basement Wali 1: Insulated Concrete Forms 225 23.5 0.044 10 Wali height: 12.0' Depth below grade: 4.0' Insulation depth: 12.0' Basement Wall 2: Insulated Concrete Forms 200 23.5 0.041 8 Wall height: 10.0' Depth below grade: 6.0' COP VInsulationdepth: 10.0' Basement Wall 3: insulated Concrete Form 1,705 23.5 0.038 65 Wall height: 8.5' Depth below grade: 7.0' Insulation depth:8.5' Basement Wall 4: Insulated Concrete Forms 500 23.5 0.042 21 Wall height: 6.0' Depth below grade: 4.0' Insulation depth: 6.0' Wall 1-Walkout:Wood Frame,24"D.C. 655 28.0 0.0 0.048 25 Window 1: Wood Frame:Double Pane with Low-E 14 0.290 4 Window 2: Wood Frame:Double Pane with Low-E 30 0.290 9 Window 3: Wood Frame:Double Pane with Low-E 30 0.290 9 Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 1 of 11 Residence.rck Gross Area Cavity Cont.Assembly or U-Factor UA Window 4:Wood Frame:Double Pane with Low-E 14 0.270 4 Door 1:Glass 38 0.310 12 Wall 2-1st Floor:Wood Frame, 16" o.c. 3,300 28.0 0.0 0.050 137 Window 5:Wood Frame:Double Pane with Low-E 30 0.290 9 Window 6: Wood Frame:Double Pane with low-E 104 0.210 22 Window 7: Wood Frame:Double Pane with Low-E 21 0.290 6 Window 8: Wood Frame:Double Pane with Law-E 26 0.290 8 Window 9: Wood Frame:Double Pane with Low-E 10 0.270 3 Window 10:Wood Frame:Double Pane with Low-E 25 0.290 7 Window 11:Wood Frame:Double Pane with Low-E 30 0.290 9 Window 12:Wood Frame:Double Pane with Low-E 30 0.290 9 Window 13:Wood Frame:Double Pane with Low-E 16 0.290 5 Window 14:Wood Frame:Double Pane with Low-E 24 0.290 7 Door 2: Glass 42 0.310 13 Door 3:Glass 82 0.310 25 Door 4:Glass 49 0.310 15 Door 5: Solid 20 0.140 3 Door 6: Solid 20 0.140 3 Door 8: Glass 20 0.220 4 Door 9:Solid 20 0.140 3 Wall 3-Upper level: Wood Frame, 16"o.c. 2,645 28.0 0.0 0.050 116 Window 15:Wood Frame:Double Pane with Low-E 8 0.270 2 Window 16:Wood Frame:Double Pane with Low-E 46 0.290 13 Window 17:Wood Frame:Double Pane with Low-E 48 0.290 14 Window 18:Wood Frame:Double Pane with low-E 27 0.270 7 Window 19:Wood Frame:Double Pane with Low-E 13 0.270 4 Window 20:Wood Frame:Double Pane with Low-E 13 0.270 4 Window 21:Vinyl/Fiberglass Frame:Double Pane with Low-E 24 0.270 6 Window 22:Wood Frame:Double Pane with Low-E 34 0.290 10 Window 23:Wood Frame:Double Pane with Low-E 12 0.290 3 Window 24:Wood Frame:Double Pane with Low-E 12 0.290 3 Window 25:Wood Frame:Double Pane with Low-E 18 0.290 5 Window 26:Wood Frame:Double Pane with Low-E 12 0.290 3 Window 27:Wood Frame:Double Pane with Low-E 21 0.290 6 Window 28:Wood Frame:Double Pane with Low-E 21 0.290 6 Window 33:Wood Frame:Double Pane with Low-E 17 0.290 5 Floor 1-Over Garage:All-Wood joist/Truss:Over Unconditioned Space 1,076 38.0 0.0 0.026 28 Ceiling 1: Cathedral Ceiling 3,325 42.0 0.0 0.025 83 Ceiling 2:Structural Insulated Panels(SIPS) 1,000 41.0 0.026 26 Ceiling 3: Flat Ceiling or Scissor Truss 215 42.0 0.0 0.028 6 Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 2 of 11 Residence.rck Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirem is listed in . gRVcheck Inspection Checklist. TT yt S M oN A,6t!6 til 411 l' o -4 - ( -7 Name-Title T- Signature Date C c sl etier r iahi s r fb z 9j 02919°' O F OF NES Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 3 of11 Residence.rck REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 37.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions Req.ID 103.1, Construction drawings and Complies Requirement will be met. 103.2 documentation demonstrate Does Not PR1)1 energy code compliance for the i . building envelope.Thermal Not Observable envelope represented on Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate Does Not 403.7 energy code compliance for PR3)1 lighting and mechanical systems. Not Observable Systems serving multiple Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not PR2)2 on loads calculated per ACCA Cooling: Cooling: Not Observable 1 Manual J or other methods Btu/hr Btu/hr approved by the code official. Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 4 of 11 Residence.rck Section Plans Verified Field VerifiedFoundationInspection Value Value Complies? Comments/Assumptions Req.ID 402.1.1 Conditioned basement wall R- R-_ Complies See the Envelope Assemblies F04)1 insulation R-value.Where interior R-- R Does Not table for values. insulation is used,verification may need to occur during Not Observable Insulation Inspection. Not Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall Complies Requirement will be met. F05)1 insulation installed per Does Not 411 manufacturer's instructions. Not Observable Not Applicable 402.2.9 `Conditioned basement wall ft ft Complies See the Envelope Assemblies F06)1 insulation depth of burial or Does Not table for values. m distance from top of wall Not Observable Not Applicable 303.2.1 A protective covering is installed Complies Exception:Requirement is F01112 to protect exposed exterior Does Not not applicable. 3 insulation and extends a minimum of 6 in. below grade. Not Observable Not Applicable 403.9 Snow-and ice-melting system Complies 1:012]2 controls installed. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) F3 FLow Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 5 ofll Residence,rck Section Plans Verified Field VerifiedFraming/Rough-In Inspection Value Value Complies? Comments/Assumptions Req.ID 402.1.1, Door U-factor, U-_ U-_ Complies See the Envelope Assemblies 402.3.4 Does Not table for values. FR1]1 Not Observable Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- Complies See the Envelope assemblies 402.3.1, average). Does Not table for values. 402.3.3, 402.3.6, Not Observable 402.5 Nat Applicable FR2]1 k 303.1.3 U-factors of fenestration products Complies Requirement will be met. FR4]1 are determined in accordance Does Not Loll with the NFRC test procedure or taken from the default table. Not Observable Not Applicable 402.3.5 Fenestration in thermally isolated U- U- Complies FR8]1 sunrooms in Climate Zones 2-8 Isolated Isolated Does Not have maximum U-0.45. Not Isolated Not Isolated Not Observable Not Applicable 402.3.5 Skylights in thermally isolated U- U- Complies FR9]1 sunrooms in Climate Zones 2-8 isolated Isolated Does Not have a maximum skylight U- Not Isolated Not Isolated Not Observablefactorof0.70.All other sunroom skylights must meet code Not Applicable requirements. 402.4.1.1 Air barrier and thermal barrier Complies Requirement will be met. FR2311 installed per manufacturer's Does Not instructions. Not Observable Not Applicable 402.4.3 Fenestration that is not site built Complies Requirement will be met. FR20]1 is listed and labeled as meeting Does Not V,AAMA/WDMA/CSA 101/I.S.2/A440 Not Observable or has infiltration rates per NFRC 400 that do not exceed code Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures Complies Requirement will be met. FR1612 sealed at housing/interior finish Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. Not Observable Not Applicable 403.2.1 Supply and return ducts in attics Complies FR12]1 insulated >= R-8 where duct is Does Not 3 inches in diameter and >_ Not Observable R-6 where<3 inches.Supply and return ducts in other portions of Not Applicable the building insulated >= R-6 for diameter>=3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as Complies FR15]3 ducts or plenums. Does Not Not Observable Not Applicable 403.4 HVAC piping conveying fluids R-_ R-_ Complies FR17]2 above 105 QF or chilled fluids Does Not below 55 OF are insulated to>R- 3 Not Observable Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 6 of 11 Residence.rck Section Plans Verified Field Verified Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions Req.ID 403.4.1 Protection of insulation on HVAC Complies FR24)1 piping. Does Not Not Observable Not Applicable 403.5.3 Hot water pipes are insulated to R- R- Complies FR18)2 >_R-3.Does Not Not Observable Not Applicable 403.6 Automatic or gravity dampers are Complies Requirement will be met. FR19]1 installed on all outdoor air Does Not intakes and exhausts. Not Observable Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 7 of 11 Residence.rck Section Plans Verified Field VerifiedInsulationInspection Value Value Complies? Comments/Assumptions Req.ID 303.1 All installed insulation is labeled Complies Requirement will be met. IN13)2 or the installed R-values Does Not provided. Not Observable Not Applicable 402.1.1, Floor insulation R-value, R- R- Complies See the Envelope assemblies 402.2.6 Wood Wood Does Not table for values. IN1)1 Steel Steel V11 Not Observable Not Applicable 303.2, Floor insulation installed per Complies Requirement will be met. 402.2,7 manufacturer's instructions and Does Not IN2]1 in substantial contact with the underside of the subfloor,or floor Not Observable framing cavity insulation is in Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wali insulation R-value. If this is a R- R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/7 of the Wood Wood Does Not table for values. 402.2.6 wall insulation on the wall IN3)1 exterior,the exterior insulation Mass El mass Not Observable requirement applies(FR10). Steel Steel Not Applicable 303.2 Wall insulation is installed per Complies Requirement will be met. IN4)1 manufacturer's instructions.Does Not Not Observable Not Applicable 303.2 Sunroom wall insulation installed Complies IN9)1 per manufacturer's Instructions. Does Not Not Observable Not Applicable 303.2 Sunroom ceiling insulation is Complies IN11)1 installed per manufacturer's Does Not instructions. Not Observable Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 1-ow Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 8 of 11 Residence.rck Section Plans Vered Field VerifiedFinalInspectionProvisions Req.ID Value Value Complies? Cornrnents/Assumptions 402.1.1, Ceiling insulation R-value. R- R- COCompiies See the Envelope Assemblies 402.2.1, Wood Wood Does Not table for values. 402.2.2, 402.2.5 L] Steel Steel Not Observable FI1]1 Not Applicable 303.1.1.1, Ceiling insulation installed per Complies Requirement will be met. 303.2 manufacturer's instructions.Does Not F12]1 Blown insulation marked every 300 ft2. Not Observable Not Applicable 402.2.3 Vented attics with air permeable Complies Exception: Requirement is F12212 insulation include baffle adjacent Does Not not applicable. to soffit and eave vents that Not Observableextendsoverinsulation. Not Applicable 402.2.4 Attic access hatch and door R- R- Complies Requirement will be met. FI311 insulation?R-value of the Does Not adjacent assembly. Not Observable Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 ACH 50 = Complies Requirement will be met. FI1711 ach in Climate Zones 1-2, and Does Not 3 ach in Climate Zones 3-8. Not Observable Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 Complies FI4]1 cfm/100 ft2 across the system or ft2 ftz Does Not 3 cfm/100 ft2 without air Not Observablehandler@25Pa.For rough-in tests,verification may need to Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 Complies F127]1 determine air leakage with ft2 ft2 Does Not either: Rough-in test:Total leakage measured with a Not Observable pressure differential of 0.1 inch Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated Complies FI2411 by manufacturer at<=2%of Does Not design air flow. Not Observable Not Applicable 403.1.1 Programmable thermostats Complies F19]2 installed for control of primary Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. Not Applicable 403.1.2 Heat pump thermostat installed Complies FI10]2 on heat pumps. Does Not Not Observable ONot Applicable 403.5.1 Circulating service hot water Complies Fill]2 systems have automatic or Does Not accessible manual controls. Not Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 9 of 11 Residence.rck Section Plans Verified Field VerifiedFinalInspectionProvisions Value Value Complies? Comments/Assumptions Re .ID 403.6.1 All mechanical ventilation system Complies FI25]2 fans not part of tested and listed Does Not HVAC equipment meet efficacy and air flow limits. Not Observable Not Applicable 403.2 Hot water boilers supplying heat Complies F[26]2 through one-or two-pipe heating Does Not systems have outdoor setback control to lower boiler water Not Observable temperature based on outdoor Nat Applicable temperature. 403.5.1.1 Heated water circulation systems Complies FI28]2 have a circulation pump.The Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe.Gravity and thermos- Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems Complies FI29]2 comply with IEEE 515.1 or UL Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that Complies F130]2 have recirculation pumps that Does Not pump water from a heated water Not Observablesupplypipebacktotheheated water source through a cold Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units Complies F131]2 tested in accordance with CSA Does Not B55.1. Potable water-side pressure loss of drain water heat Not Observable recovery units< 3 psi for Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent Complies FI6]1 fixtures or 75%of permanent Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. Not Applicable 404.1.1 Fuel gas lighting systems have Complies FI23]3 no continuous pilot light. Does Not Not Observable Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 10 of 11 Residence.rck Section Plans Verified Field VerifiedFinalInspectionProvisions Value Value Complies? Comments/Assumptions Req.lD 401.3 Compliance certificate posted, Complies Requirement will be met. F17]2 Does Not Not Observable Not Applicable 303.3 Manufacturer manuals for Complies Fi18]3 mechanical and water heating Does Not systems have been provided. Not Observable Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Perrotta Residence Report date: 10/03/17 Data filename: C:\Users\Stephen A\Documents\Projects\ADKPC\Old Coach Rd\Resck\Perrotta Page 11 of 11 Residence.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 28.00 Below-Grade Wall 23.50 Floor 38.00 Ceiling / Roof 42.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.21 Door 0.31 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments Job: Perrotta Rresidence wrightsoft, Load Short Form Date: Oct 31,2017 Entire House By: Project Inf• For: PERROTTA RESIDENCE 60 KNOX RD. QUEENSBURY, NY 12804 Design Information Htg CIg Infiltration Outside db(°F) 18 81 Method Simplified Inside db(°F) 68 75 Construction quality Average Design TD (°F) 86 6 Fireplaces 4 (Average) Daily range M Inside humidity (%) 50 50 Moisture difference (gr/Ib) 52 10 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade C^t'Y Model Cond ; FILE Vf AHRI ref Coil AHRI ref Efficiency 80 AFU E Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 3613 cfm Actual air flow 3613 cfm Air flow factor 0.015 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 ROOM NAME Area Htg load CIg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) Family Room 552 7438 786 113 38 Bedroom 4 352 4889 328 75 16 Ensuite 4 60 2757 788 42 38 Theatre 320 4054 451 62 22 Bar 196 1391 10 21 0 Hum/Wine 105 1057 9 16 0 Mech2 144 2801 26 43 1 Ensuite 4a 36 285 9 4 0 Pwdr 36 78 0 1 0 Base Hall 28 60 0 1 0 Base storage 21 45 0 1 0 Base stairs 84 181 0 3 0 Mech1 124 1305 11 20 1 Gym 196 2769 82 42 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Oct-31 15:41:14 wrightsOft Right-Suite®Universal 2017 17.0.04 RSU15058 Page 1 CCA ...s\rkmarsh\Documents\Wrightsoft HVACTEROTTA.rup Calc=MJ8 Front Door faces: N Sunroom 340 26067 8692 397 420 Kitchen 256 3034 542 46 26 Great room 552 37782 12866 576 621 Master Bedroom 352 5563 862 85 42 WIC 1 60 3324 2157 51 104 WIC 1a 60 887 146 14 7 Ensuite 1 290 10016 2940 153 142 M udroom 108 16295 6786 248 328 Entry Hall 76 17 0 0 0 Laundry 50 436 19 7 1 Pwdr2 27 0 0 0 0 Pantry 18 0 0 0 0 Dining 180 1933 985 29 48 Foyer 327 5559 1848 85 89 Bed Room 3 265 14956 4724 228 228 WIC 3 45 3076 771 47 37 Ensuite 3 54 2530 875 39 42 Loft 420 23493 8739 358 422 Bed Room 2 275 14277 4883 218 236 WIC 2 54 1899 847 29 41 Ensuite 2 90 3165 1411 48 68 Future Space 760 33568 12226 512 590 Entire House 6913 236990 74818 3613 3613 Other equip loads 0 0 Equip. @ 0.86 RSM 64493 Latent cooling 1329 TOTALS 6913 236990 65822 3613 3613 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htSOft 2017-Oct-31 15: age 29Right-SuiteCS Universal 2017 17.0.04 RSU15058 Page 2 CCA ...s\rkmarsh\Documents\Wrightsoft HVAC\PEROTTA.rup Calc=MJ8 Front Door faces: N Project Summar Job: wrightsoft`° y Date: Oct 31,2017 Entire House By: Proiect Information For: PEROTTA Notes: Design Information Weather: Adirondack Rgnl, NY, US Winter Design Conditions Summer Design Conditions Outside db 18 OF Outside db 81 OF Inside db 68 OF Inside db 75 OF Design TD 86 OF Design TD 6 OF Daily range M Relative humidity 50 % Moisture difference 10 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 236990 Btuh Structure 74818 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 236990 Btuh Use manufacturer's data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 64493 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 4 (Average) Structure 1329 Btuh Ducts 0 Btuh Heating Coolingg Central vent (0 cfm) 0 Btuh Area(ftz) 6913 6913 Equipment latent load 1329 Btuh Volume(ft3) 66879 66879 Air changes/hour 0.40 0.19 Equipment total load 65822 Btuh Equiv.AVF (cfm) 442 212 Req. total capacity at 0.70 SHR 7.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 3613 cfm Actual air flow 3613 cfm Air flow factor 0.015 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I'1 htSOft" 2017-Oct-3115:41:14 W g Right-Suite®Universal 2017 17.0.04 RSU15058 Page 1 SCA ...s\rkmarsh\Documents\Wrightsoft HVAC\PEROTTA.rup Calc=MJ8 Front Door faces: N N Level t Z3615 ctm 1 Fam!!y Room 75 Cfm Bedroom 4 Cold Storage Theatre 62 cfm Ensuite 4 42 Cf I Ensuite as PHdr 3ase HailBasestairs® 1cf t cr Baterstorage Bar 19 cfm Mecht Hum;Wine Gym 170m 14 dm 36 CIM Mec h2 z 36 Um Job#: Scale: 1 : 153 Performed for:Page 1 PEROTTA Right-Suite®Universal 2017 17.0.04 RSU15058 2017-Oct-31 16:12:32 ents\Wrightsoft HVAC\PEROTTA.ru N Level 2 Great room 124IIQQ124((al 2qL 24&24 cfm Master Bedroom Kitchen Sunrroom qq85cfm 46 cfm z 105&05&05rBTln105 cf WIC 1 104 cfm Stairs First W IC.7a-= antry dr2 14 cfm Foyer Dining 89 dm 50 cfm Entry Hall 5,,p 0 cf ay' qw 77 cfm Laundry I7cfm Garage ppt1 t1Mudrq000lIm 4 90y61Yn109 cf Job#: Scale: 1 : 153 Performed for:Page 2 PEROTTA Right-Suite®Universal 2017 17.0.04 RSU15058 2017-Oct-31 16:12:32 ents\Wrightsoft HVAC\PEROTTA.ru N Level 3 LFGreatBow Bedgo Bad 21q Sunroam vain; 114 +i4 cfm it8 tlt8 cfm Stairs 2,.d F1, WIC 3 Ensuite 3 Ensrrite 2cfrtr ILSIVlk I, Ibl 68 4ct 47 cfm ®42 cl i Loft idt n ntat jm attic IIppFIuture Space II IIqq t i 8€Nhi t 8 t t 8'€Aht 7 8'E/+fit t 8 cf. Landing Stairwell Job#: Scale: 1 : 153 Performed for:Page 3 PEROTTA Right-Suite®Universal 2017 17.0.04 RSU15058 2017-Oct-31 16:12:32 ents\Wrightsoft HVAC\PEROTTA.ru Air Conditioning Contractors of America •Manual S 2nd Edition Residential Equipment Selection e Project Information Design Information Name PERROTTA RESIDENCE Outdoor Design Temperature-Summer 81 Address 60 KNOX RD. Indoor Design Temperature-Summer 68 City QUEENSBURY Indoor Design%RH-Summer 50 State NY Zip Code 1 12804 Outdoor Desgn Temperature-Winter 18 System ID Project Location Elevation System Type Air-Air,Coding Only,Single-Speed Compressor,Mild Winter or Latent Load Manufacturer American Standard Furnace# S9X2C10014PS AFUE 95.0 Proposed Equipment Manufacturer American Standard AHU/Cofl# 4PXCCU36BS3 SEER 14.0 Manufacturer American Standard Condenser# 4A7A4036L1000 HSPF Manufacturer Package# Fan Speed Med Heat Total Sensible Latent SHR Manual J Load Calculations Loss BTUH BTUH BTUH DIV/0! To interpolate capacities,enter the listed capacities from the manufacturers cooling performance charts that are less than the design temperatures here Out DB per OEM Chart 75 Design Return Air Total Sensible Latent SHR In DB per OEM Chart 68 CFM IF wb) BTUH BTUH BTUH Capacity from MFG table 68 40 40 Interpolated Capacity 1200 63 35 35 Capacity from MFG table 62 34 34 To interpolate capacities,enter the listed capacities from the manufacturers cooling performance charts that are greater than the design temperatures here Out DB per OEM Chart 85 Design Return Air Total Sensible Latent SHR In DB per OEM Chart 68 CFM IF wb) BTUH BTUH BTUH Capacity from MFG table 68 40 40 Interpolated Capacity 1200 63 35 35 Capacity from MFG table 62 34 34 Out DB per OEM Chart 81 Design Return Air Total Sensible Latent In DB per OEM Chart 68 CFM IF orb) BTUH BTUH BTUH SHR Interpolated Equipment Capacity 35 35 Excess Latent Capacity Calculation 18 18 Mfg.Equipment Match-Up Adjustment Factor 1.00 1.00 1200 63 Attitude Adjustments 1.00 1.00 Capacity @ Design Conditions 35 18 18 0.50 Equipment Capacity as a%of Design DNI01 MIMI DIV/01 Oversizing Limits 115% 150°/6 Attitude Adjustments Heat Pump Data Capacity Capacity Balance Supplimentbl 100 @ 47°F db @ 17'F db Point Heat Required d applicable) Cap.@ 47°F db Cap.@ 17'F db Select Furnace or Boiler Option Input Output Attitude Furnace of Load Oversing Capacity warm Adjustment Capacity Limits Furnace Data(if applicable) 100,000 95,000 1.00 95000 DIVIO! 2001/6 KW Proposed KW Required of Load Oversizing LimitsElectricFurnace DIVIO! 17S/. CERTIFIED www.ahridirec or or Certificate of Product Ratings AHRI Certified Reference Number: 8673488 Date: 11/2/2017 Product: Split System: Air-Cooled Condensing Unit, Coil Alone Outdoor Unit Model Number: 4A7A4036L1 Indoor Unit Model Number: 4PX*CU36BS3 Manufacturer: AMERICAN STANDARD Trade/Brand name: AMERICAN STANDARD Region: Southeast and North (AL,AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC,TN, TX,VA AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT,VT,WA,WV,WI,WY, U.S.Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015, are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016, central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. Series name: SILVER 14 Manufacturer responsible for the rating of this system combination is AMERICAN STANDARD Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34400 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.00 IEER Rating (Cooling): Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at v,;ow.ahrldirectory.org. TERMS AND CONDITIONSnThisCertificateanditsscontentscontentsareproprietaryproductsofAHRI.This Certificate shall only be used for individual,persol and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, NOW 111MI personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,dick on`Verify Certificate'link He make life betteT- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 2014 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.. 131541239672144041 fantech° a systemair company Dowmerrt type: Product card Document date: 2017-11.06 Generated by: Systemair Online Catalogue SHR 1504 FRESH AIR APPLIANCE Item no. 40072 Description Airflow up to 149 cfm @ 0.4"PS serves 3-5 bedroom homes Three speed ventilation control External dry contacts for quick connection of remote controls Compatible with Fantech's low-voltage controls Easy access service door Application iFantech's side port connection HRV for budget conscious house projects. How it works the SHR 1504 unit brings a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air.During winter,fresh incoming air is j tempered by the heat that is transferred from the outgoing air so you save on energy costs,while during summer,the incoming air is pre-cooled if the house is equipped with an air cooling system.The SHR 1504 is equipped with automatic defrost mechanisms so you can use your HRV all year long. Defrost cycle A preset defrost sequence is activated at an outdoor air temperature of 23°F and lower.During the defrost sequence,the supply blower shuts down&the exhaust blower switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation,and continues the cycle. Technical parameters Nominal data Voltage 120 Frequency 60 Phase 1 Rated power 156 Current 1.3 Airflow high 149 Static pressure 0.4 Certificate CSA,HVI Weight 45.2 Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 1/5 Document type:Product card I Document date:2017-11-06 1 Generated by:Online catalogue Energy performance Supply Net Consumed Sensible Apparent Latent temperature airflow power recovery sensible recovery/moisture Heating efficiency effectiveness transfer T(°C) cfm(Us) W 32(0) 67(31) 72 60 73 0.11 32(0) 109(51) 98 59 70 0.00 32(0) 161 (76) 144 55 63 0.00 13(-25) 68(32) 73 56 77 0.02 Dimensions t I A i A B c D E Duct size 2 1/4(57) 23 1/3(597) 2 5/8(67) 17 3/8(441) 16 1/8(410)1 6(152) Dimensional information is in inche(mm) Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 2/5 Document type:Product card I Document date:2017-11-06 1 Generated by:Online catalogue Wiring D,. T2. P4- AjVKR i I. 04 y r for 4#r Accessories Electric accessories RTS2 Pushbutton Timer(40164) MDEH1 Low Voltage Dehumidistat(40172) RTS3 Pushbutton Timer(40376) EDF1 Multi-Func Ctri(40375) EDF7 Elec Multi-Funct Dehum(44883) ECO-TOUCH Pqrm Wall Control(44929) Accessories COM6P Supply and Exhaust Hoods(40222) MGE 5 Metal Exhaust Grill(4113701 MGE 6 Metal Exhaust Grill(411371) MGS 4 Metal Supply Grill(411368) MGS 5 Metal Supply Grill(411369) MGS 6 Metal Supply Grill(411242) MGE 4 Metal Exhaust Grill(411106) FIDT 4 Insulated Fiex Duct(411061) FIDT 5 Insulated Flex Duct(411062) FIDT 6 Insulated Flex Duct(411064) Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 3/5 Document type:Product card I Document date:2017-11-06 1 Generated by:Online catalogue Documentation 405190 Residential VHR-SHR Installation Manual.pdf(2,33MB) 405191 SHR VHR Homeowner's Manual EN FR.pdf,(1 15MB) 11SHR Series Service Manual.pdf(160,49kB) SHR1504.rfa 403787 SHR1504 Spec Sheet EN.pdf r3R'-,9 kP Performance Diagrams Diagrams and calculations are made for the performance with clean filters. Supply Extract 2 2 1.5 5 CM c CL ti 0.5 0.5 00 40 s0 120 16G 200 00 4 0,80 120 160 200 Q [cfm] Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 4/5 Document type:Product card I Document date: 2017-11-06 1 Generated by:Online catalogue Specification text Fans Two(2)factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life and maintenance-free operation. Heat Recovery Core Aluminum heat recovery core covered by a limited lifetime warranty.Core dimensions are 9"x 9"(229 x 229 mm)with a 15"(380 mm)depth.Our heat exchangers are designed and manufactured to withstand extreme temperature variations. Frost Control A preset frost control sequence is activated at an outdoor air temperature of 23°F(-5°C)and lower.During the defrost sequence,the supply blower shuts down&the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy.The unit then returns to normal operation,and continues cycle. Serviceability Core,filters,fans and drain pan can be easily accessed through latched door.Core conveniently slides out on our new easy glide core guides. 17" 432 mm)of clearance is recommended for removal of core. Case 24 gauge galvanized steel.Baked power-coated paint for a superior adhesion and resistance. Insulation Cabinet is fully insulated with 1"(25 mm)high density expanded polystyrene. Filters Two(2)washable electrostatic panel type air filters 8.5"(216mm)x 15"(380mm)x 0.125"(3mm). Controls External three(3)position(Low/Stand By/Medium)rocker switch that will offer continuous ventilation.Fantech offers a variety of external controls. see accessories) Installation Unit is typically hung by using installation kit supplied with unit.Mounting bolts provided on top four(4)corners of unit. Warranty Limited lifetime on aluminum core,7 year on motors,and 5 year on parts. Requirements and standards Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 113 Standard applicable to ventilators Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of test relating to CSA C439 Standards HVI certified Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 5/5 Document type:Product card I Document date:2017-11-06 1 Generated by:Online catalogue ) Vo� BUILDING CONSTRUCTION Envelope Leakage Test Report Energy Savers Performance Methods ° • f Pr ect Name: Perrotta Builder Name: Bob Picard Stroeet: 60 Knox Rd.Queensbury NY 12804 Cond..Volume: 76,092-ft3 Coi'd. I Ioorjpea: 7,500-if Envelope Leakage Test Results Leakage Characteristics Sin le or Multi Point Test Data: Required ACH(50)from QUSE PRES,SU R402.4.1.2 Testing.: 3-ACH(50)or Less 2 pa cf Tested ACH(50)*: 2.513 ACH Tested leakage must be less than or equal to the required ACH(50)shown on Form R402.4.1.2 Testing. 5 Pa cfm 6 Pa cfm During testing; 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration -control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems if installed at the time of the test, shall be turned off;and 6.Supply and return registers,it installed at the time of the test,shall be fully open. I herby certify that the above envelope leakage Michael L. Bennett performance results demonstrate compliance Energy Saver Consulting with New York Energy Code requirements in 3 Raymond Lane accordance with Section R402.4.1.2 Testing. Clifton Park NY, 12065 857-210-6453 • Signature:. EI1e1`ay S1VC'I"S Printed Name: pc DATE: /U ENVIRONMENTAL DESIGN �32, -2oQ ect) PARTNERSHIP, LLP. 900 Route 146 Clifton Park,NY 12065 (P)518.371,7621 (F)518.371.9540 edpllp.com Shaping the physical environment April 15,2022 Town of Queensbury Building &Codes 742 Bay Road Queensbury, NY 12804 D E C, `a 0 V IE Attn: John O'Brien, Charlie Dyer Re: Perrotta Residence APR 0 202? 60 Knox Road TOWN OF QUEEW BURY BUILDING&CODE Gentlemen: For some unknown reason this project has yet to have had the `sign-off for the wastewater system although it has been in operation for two years. This letter shall serve as the compliance letter for the wastewater system serving the five-bedroom residence located at 60 Knox Road. The plans associated with the wastewater system as part of site plan approval for this project are as follows: Proposed Site Plan for the Perrotta Residence 60 Knox Rd./Assembly Point Rd. Town of Queensbury • Sheet S-1 Overall Parcel/Existing Conditions Plan • Sheet S-2 Site Plan • Sheet S-6 Wastewater Details .On March 23rd of this year I,along with Builder Steve Adler and Contractor Jim Jones, examined the existing system by accessing the pump chamber and activated the pump system by the float controls. We had uncovered the distribution box thus were able to witness flow through the force main up into the d-box. Each of the four outlets to the Eljen GFS trench laterals were receiving flow from the d-box. I had previously witnessed the installation of the absorption field system when Jim Jones installed it in 2019. Please note the attached 'As-Built' plan for the wastewater system which indicates a slight change from the originally approved plan. The four lateral system was configured using the area of the reserve instead of the original linear configuration. Tie distances to the d-box are provided. Based on my observation of the field installation and recent review of the pump operation, including the,alarm signal, I can say that the system was constructed in compliance with the intent of the approved design using the materials as specified and in an acceptable configuration as.noted. The system appears to be operating normally with no indications of any operating problems. With this engineering sign-off in-place the Town may proceed with finalizing the certificate of occupancy. Sincerely, -Paivlis Mac:Elro4 Dennis MacElroy, PE Attachment