SOLAR-000664-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000664-2017 Tax Map No: 296.13-1-80 Permission is hereby granted to: Linda Combs For property located at: 95 MONTRAY RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Linda Combs Solar Panel-Residential $0.00 Owner Address: 95 Montray RD Total Value $0.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Repower 210 Washington Ave EXT Albany,NY 12804 Plans&Specifications Solar Panel Systems (No rafter upgrades) $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,October 29,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eensb id ay totfo' 17 SIGNED BY: the Town of Queensbury. Director of Building&Code Enforcement Office Use Only SOLAR PANEL Permit#: �StiLAZ � It-7 PERMIT APPLICATION Permit Fee:$ Town of CLuccusbury Invoice#: 742 Bay Road,Queensbury,NY 12804 AY 4W A/0° P: 518-761-8256 www.gueensbury.net ((`` p � C1Eod � Q1L'I° ' FOCT 2 3 2017 Linda Combs TOWN OF 0 +-r�an,eat asrName Tale COMMUNITY DEVELOPMENT 95 Montray Road Queensbury NY 12804 St<to Section Block of Number �( � �� 2-4 FamiN ❑Commercial Other '! 1 • f Solar PV System 15.105 k,\'DC Make sure your selection matches the Construction Documents included with this application. ❑ Supply side connection with microinverters ❑Load side connection with DC op6mir_er ® Supply side connection with DC optimizers ❑Load side connection with microinverters ❑ Supply side connection with string inverter ❑Load side connection with stringinvorter Repower ntractor Business Nfim, 210 Washington Ave Ext Albany NY 12203 Renee Dufek 518-869-6862 renee.du@aecenergy.com Town of Queensbury Building&Code Enforcement Solar Panel Permit Application Revised July 2017 Electrician Business Name Electrician Business Address City State Zip Electrician Contact Name Phone Number Electrician License Number(s) Electrician Email Please sign below to affirm that all answers are correct and that you have met all the conditions and requirements to submit a unified solar permit_ OteAt Property O ner's Signature Date Solar Installation Company Represe ative Sionat a Town of Queensbury Building&Code Enforcement Solar Panel Permit Application Revised July 2017 SCOPE L A WORK RE POWER TO INSTALL A SOLAR PHOTOVOLTAIC(PV)SYSTEM � f" �f�rrf rr•� r•r�+.o �• ••� THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED +' ,ys y r�',E~ (�� ry r1I�" BY SOLAR UNIVERSE WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. ''. g "� �` s +' r 210 Washington Ave Extension THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. :I > y Albany,NY 12203 (518)213-8786 r � • � r ELECTRICAL NOTES 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. Y' *` 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90°C WET ENVIRONMENT. �^�� .y '+r•` "o-`,,, ri r 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. ` " )r Linda Combs 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL /• ' x' 95 Moniray Road f COMPLY WITH NEC 110.26. !� ° Queensbury,NY 12804 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL •�� r " FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACESSORIES TO FULFILL r ,•° * a " `" f APPLICABLE CODES AND STANDARDS. `� • r ±rd 6. WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, ~` - Y` r�, 'T System ySy em Type:Grid Tied THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. � ., ' 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. s.` �. r.,4). • Module Type:Hyundai HiS-S285RG 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE • #of Modules:41 SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION ' ,*..a 't • f' 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG ''..� • Inverter:a P30 Po er Optimizer w/ r ,,.,✓ "r, Solaredge P300 Power Optimizer OR ILSCO GBL-4D6T LAY-IN LUG. Racking:Ironridge XR100 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/negative) Solar Mounts:S-51 Versabracket OR THE DC SIDE OF THE PV SYSTEM IS UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. .:` .�• •' ':' �+ - • • DC Watts:11.685 kW DC STC GOVERNING CODES • rr Existing House Electrical: •' �t (E)Main Service Panel:200A 2013 NATIONAL ELECTRICAL CODE d f :•Y C Air • Grid Voltage:120/240V 2013 INTERNATIONAL BUILDING CODE 2010 RESIDENTIAL CODE OF NEW YORK STATE p * �'�+ x,•�/. 6:� Special Info: UNDERWRITERS LABORATORIES(UL) �`� 8 ) .--+ . STANDARDS '�� IRoof Type:Corrugated Metal OSHA 29 CFR 1910.269 ; _ r Array 1 Rafter Size:2x8 Rafter 24"O.0 Array 1 Pitch:28°Azimuth:2400 1 Array 2 Rafter Size:2x8 Rafter 24"O.0 SHEET INDEX 1.~ Array 2 Pitch:28°Azimuth:240° COVER Array 3 Rafter Size:2x8 Rafter 24"O.0 PV-1 PLOT PLAN / ._V/. �I n Array 3 Pitch:28°Azimuth:150° PV-2 ROOF LAYOUT V„ V r WEENSBURY Array 4 Rafter Size:2x8 Rafter 24"O.0 PV-2A SECTION VIEW/MOUNTING DETAIL Array 4 Pitch:28°Azimuth:60° PV-3 ELECTRICAL 3-LINE DIAGRAM Arra • Rafter 2x8 Rafter 24"O.0 PV-4 AMPACITY CALCULATIONS LDIG CArray 5 Pitch: 4Azimuth:240* PV-5 LABELS BUNh Avg High Temp.:87.8° CUTSHEETS ATTACHED F1 L � y Reviewed By, Rec.Low Temp:-9_4° Date: Array info: Module Weight(lb): 41.2 Ibs. Avg.Standoff Spacing(ft): 4'Max. TOWN OF QUEENSBURY BUILDING DEPARTMENT REV BY DATE COMMENTS Based on our limited examination,compliance Sign: with our comments shall not be construed as indicating the plans and specifications are in Date:09/21/2017 full compliance with the Building Codes of New York State. // COVER 296.13-1-80 SOLAR-000664-2017 Combs, Linda 95 Montray Road RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 Linda Combs 95 Montray Road Queensbury,NY 12804 I iI System Spec: System Type:Grid Tied Module Type:Hyundai HiS-S285RG #of Modules:41 PROPERTY Inverter:SolarEdge SE10000A-US w/ LINE Solaredge P300 Power Optimizer Racking:Ironridge XR100 Solar Mounts:S-51 Versabracket DC Watts:11.685 kW DC STC vExisting House Electrical: I 0 I (E)Main Service Panel:200A Grid Voltage:120/240V O O I Special Info: Roof Type:Corrugated Metal _ FRONT OF HOME Q Array 1 Rafter Size:2x8 Rafter 24"O.0 Array 1 Pitch:28°Azimuth:240° of A x } Array 2 Rafter Size:2x8 Rafter 24"O.0 Q Array 2 Pitch:28"Azimuth:240° Array 3 Rafter Size:2x8 Rafter 24"O.0 Z Array 3 Pitch:28°Azimuth:150° aR av s I Array 4 Rafter Size:2x8 Rafter 24"O.0 Array 4 Pitch:280 Azimuth:60° Array 5 Rafter Size:2x8 Rafter 24"O.0 Array 5 Pitch:14°Azimuth:240° Avg.High Temp.:87_8° Rec.Low Temp:-9_4° DRIVEWAY ' I Array info: Module Weight(lb): 41.2 lbs. — _ Avg.Standoff Spacing(ft): 4'Max. N Sign: PROPERTY PLAN Date:09/21/2017 SCALE: %s"=1'-0" P V- 1 LEGEND RE UTILITY METER POVVM BY SOLAR UNIVERSE MAIN SERVICE PANEL 210 Washington Ave Extension Albany,NY 12203 INVERTER (518)213-8786 CORRUGATED METAL ROOFING ❑ AC DISCONNECT SOLAR TYP. ❑ DC DISCONNECT MOUNTS .�� 17-11 / ❑ JUNCTION BOX Linda Combs TYP. I 16-6 ❑ COMBINER BOX 95 Montray Road 41 HYUNDAIQueensbury,NY 12804 285 WATT ❑ SUBPANEL MODULES ❑ LOAD CENTER - System Spec: TYP. y, 0 PV METER/MONITORING • System Type:Grid Tied • Module Type:Hyundai HiS-S285RG .. O SOLMETRIC READING #of Modules:41 CONDUIT RUN • Inverter:SolarEdge SE1000OA-US w/ PV2 Solaredge P300 Power Optimizer i O GAS METER . Racking:Ironridge XR100 28-6- �---� O SOLAR ROOF MOUNTS Solar Mounts:S-5!Versabracket ®FIRE SETBACK • DC Watts:11.685 kW DC STC Q O u>ADuLcuunoas Existing House Electrical: andwewei 41.]w, (E)Main Service Panel:200A SNAP N RACK RorModwes 41 a. Grid Voltage:120/240V RAIL TYP. Mod.ie Sq.rt. 17.628 Sq.rc Total Module Wei t IM.]ID,. Special Info: ToW len h or Rail 3n V: Rm Weigild Per Fo.t 096 Roof Type:Corrugated Metal FRONT OF rorai Pail Weight ms wa Array 1 Rafter Size:2x8 Rafter 24"O.0 HOME 4 O St doff I8 Ea. • Array 1 Pitch:28°Azimuth:240° RIDGE — wei Persaomn Array 2 Rafter Size:2x8 Rafter 24"O.0 31' Total 2 Pitch:28°Azimuth:240° 21'-10" wTory we r nnruK Array A D Pd duud n.sts uK. Array 3 Rafter Size:2x8 Rafter 24"O.0 2 u2 Tory uvea 72.34 .k • Array 3 Pitch:28°Azimuth:150° Dead refs LOW MI.P.Ft • Array 4 Rafter Size:2x8 Rafter 24"O.0 < • Array 4 Pitch:28°Azimuth:60° • Array 5 Rafter Size:2x8 Rafter 24"O.0 Array 5 Pitch:14°Azimuth:240° • Avg.High Temp.:87_8° 1/' l4 16'4" Rec.Low Temp:-9_4° Array info: • Module Weight(lb): 41.2 lbs. € • Avg.Standoff Spacing(ft): 4'Max. 21-10" 34'-6" V1 Sign' DRIVEWAY Date:09/21/2017 OROOF PLAN SCALE:i6"=,'_0° PV-2- MODULE MOUNTING RE MWER SOLAR MODULE CLAMP BY SOLAR UNIVERSE SNAP N RACK 210 Washington Ave Extension RAIL TYP Albany,NY 12203 E CHANNEL CLAMP (518)213-8786 L-FOOT / S-5!VERSABRACKET 5' 14Y2 %"-16 HEX (E)METAL RONUT S-5!FA APPLIED SELinda Combs 95 Montray Road sQueensbury,NY 12804 /LAGARRAY 1 & 5 SECTION 2X8 RAFTER @ System Spec: SCALE:Y4'=1'-0" • System Type:Grid Tied OMOUNTING DETAIL Module Type:HyundaiHiS-S285RG #of Modules:41 SCALE:Ya'=1'-0" Inverter:SoiarEdge SE1000OA-US w/ Solaredge P300 Power Optimizer E j Racking:Ironridge XR100 �. Solar Mounts:S-5!Versabracket DC Watts:11.685 kW DC STC y-� Existing House Electrical: (E)Main Service Panel:200A � Grid Voltage:120/240V i Special Info: Roof Type:Corrugated Metal . Array 1 Rafter Size:2x8 Rafter 24"O.0 . Array 1 Pitch:28°Azimuth:240° Array 2 Rafter Size:2x8 Rafter 24"O.0 ARRAY 3 SECTION Array 2Pitch:28°Azimuth:240° SCALE:Y4"=1'-0" Array 3 Rafter Size:2x8 Rafter 24"O.0 Array 3 Pitch:28°Azimuth:150° Array 4 Rafter Size:2x8 Rafter 24"O.0 Array 4 Pitch:28°Azimuth:60° Array 5 Rafter Size:2x8 Rafter 24"O.0 C Array 5 Pitch:14°Azimuth:240° Avg.High Temp.:87_8" Rec.Low Temp:-9_4° / Array info: Module Weight(Ib): 41.2 lbs. Avg.Standoff Spacing(ft): 4'Max. Sign: ARRAY 2 SECTION OARRAY 4 SECTION Date:09/21/2017 SCALE:Yd'=V-0" SCALE:Y4"=1'-0" PV-2A Inverter Data Temperature Data from Module Data (provided by ASHRAE (provided by manufacturer) RE POWER BY SOLAR UNIVERSE manufacturer) 210 Washington Ave Extension Average High Temp.(F°) 87.8° Make of Model HYUNDAI Albany,NY 12203 Make of Model SOLAREDGE HiS-S285RG (518)213-8786 Record Low Temp.(F°) -9.4° Model Number SE1000OA-US Max DC Volt String per Inverters 3 Max Power Point(MPP)Current(Impp) 8.9A Rating500V Max Power Point(MPP)Voltage(Vmpp) 31.8V Max AC Output 10000W Number of Inverters , Linda Combs Open Circuit Voltage(Voc) 38.7V Nominal AC 240V 95 Montray Road Voltage Short Circuit Current(Isc) 9.5A Queensbury,NY 12804 Max AC Current 41.6A Max Series Fuse(OCPD) 15A Max Power(Pmax) 285W System Spec: Max Voltage(typically less than 600V System Type:Grid Tied C 600V Module Type:Hyundai HiS-S285RG #of Modules:41 Inverter:SolarEdge SE1000OA-US w/ OPERATING CURRENT:8.9A Solaredge P300 Power Optimizer OPERATING VOLTAGE:350V Racking:Ironridge XR100 MAX SYSTEM VOLTAGE:500V Solar Mounts:S-5!Versabracket SHORT CIRCUIT CURRENT:11.875A DC Watts:11.685 kW DC STC Existing House Electrical: (E)Main Service Panel:200A (E) 100A Grid Voltage:120/240V SOLAREDGE P-300 (6)iDAWGPV-WIRE/USE-2 CONDUCTORS MAIN SERVICE POWER OPTIMIZERS (1)10 AWG BARE Cu GROUND PANEL(N)ILCSpecial Info: rN) PER MODULE IN TREE AIR INSULATION 8 UTILITY METER STRING 1 Roof Type:Corrugated Metal PIERCING UTILITY - - - CONNECTORS GRID Array 1 Rafter Size:2x8 Rafter 24"O.0 0 120/24ov Array 1 Pitch:28°Azimuth:240° 14 (E)100A MAI SINGLE Array 2 Rafter Size:2x8 Rafter 24"O.0 BREAKER PHASE Array 2 Pitch:28°Azimuth:240° 1 STRING OF 14 HYUNDAI 285 (6)10 AWG THwN CONDUCTORS (1)10 AWG THWN GROUND Array 3 Rafter Size: fte 2x8 Rar 24"O.0 PANELS TOTAL OF 41 MODULES IN Y,"EMT CONDUIT Array 3 Pitch:28°Azimuth:150° STRING 2 JUNCTION (E)LOAD Array 4 Rafter Size:2x8 Rafter 24"O.0 (N) A-US INVEREDGETER Arra 4 Pitch:28°Azimuth:60° * - - - NEMAO R UL SE10000A-US INVERTER N t00A (N)100A FUSED AC y LISTED w/INTEGRAL DC 8 AC ( ) Array 5 Rafter Size:2x8 Rafter 24"O.0 1 14 DISCONNECT NON-FUSIBLEDISCONNECT (N)SPRUCE PV DISCONNECTT W/BOA FUSES Array 5 Pitch:14°Azimuth:240° c _ METER NEMA 3R FOR OCPD Avg.High Temp.:87_8° 1 STRING OF 14 HYUNDAI 285 NEMA 3R Rec.Low Temp:-9_4° PANELS TOTAL OF 41 MODULES ' 80A FUSE Lj: Ll L1 STRING 12 �i 11 �© Array info: . - _ G O G Module Weight(Ib): 41.2 lbs. C cND GND Avg.Standoff Spacing(ft): 4'Max. 1 •.• 13F �GND ° 1 STRING OF 13 HYUNDAI 285 c PANELS TOTAL OF 41 MODULES (2)6 AWG THWN CONDUCTORS N (1)6 AWG TH WN NEUTRAL (1)6 AWG THWN GROUND IN V EMT CONDUIT Sign: Date:09121/2017 GROUND ROD NOTE:DC IS UNGROUNDED PV-3 RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 Linda Combs 95 Montray Road ROPOWER RO POWER Queensbury,NY 12804 BY SOLAR UNIVERSEBY SOLAR UNIVERSE Ampacity Calculations Ampacity Calculations System Spec: Wiring Location: Nodule to InCurrent)rter(Diraet Cunt) Wkirq Location: Inverter t°s'^rlee Entrance(Alt'r^'8"y current) System Type:Grid TiedModule Type:Hyundai HIS-S285RG All calculations show minimum sizing for arrpaciry AN calculations s0ow minanurn stung for ampaaty #of Modules:41 Actual wire sizing may be larger for voltage drop or other factors Actual wire suing may be larger for voltage trap or other factors Inverter:SolarEdge SE 1000OA-US w/ All calculations are according the the 2014 National Electric Code Ali calculations are according tine the 2014 National Electric Coda Solaredge P300 Power Optimizer Modules:Hyundai HIS-S285RG Modules:Hyundai HIS-328511143Inverter:SolarEdge SE18000A-UA-0 S Inverter:SolarEdge SE76690s Racking:Ironridge XR100 Solar Mounts:S-5!Versabracket DC Watts:11.685 kW DC STC initial Mout Values Initial Mout Values Amos Air Inverter Contlpus AC orput(walls) 10000 Isc(shat Circuit Current) 9.50 Marc—opsrah"Voltage 240 Wails YBh! Armor Existing House Electrical: Number of circuits 9.50 X 1 9.5 10000 1 240 4187 (E)Main Service Panel:200A Maximum Circuit Current Grid Voltage:120/240V (NEC 690.8(A)(1+2) 9.50 X 156% 14.62 Inverter Conliuious AC Amps 4187 Minimum over mml device 15.00 Number of Inveaen; 41.67 x 1 = 41.67 SIZE Avec 8 Owrcrrrerd da device ratting Special Info: Chosen Conductor Type NEC SM.$(BN3) 41.67 x 125% = 5206 Roof Type:Corrugated Metal THHN,RHW-2 or USE-2 10 Minimum overcaren device 60.00 Array 1 Rafter Size:2x8 Rafter 24"O.0 Circa Breaker size per NEC 2408(A) 6" . Array 1 Pitch:28°Azimuth:240° Conductor Dentin SIZE AVMs Array 2 Rafter Size:2x8 Rafter 24"O.0 NEC 690.31(C)ref(NEC 310.16) Chosen Condracter Type Conductor 90•C Ampacity 30 Array 2 Pitch:28°Azimuth:2400 Conduit Fill Derating 2 30.00 x 1.00 30.00 TMs• 2 RHw-2 or 6 Array 3 Rafter Size:2x8 Rafter 24"O.0 Tamperalure Derating`F 114-122 30.00 x .82 = 24.60 Conductor Derailing Array 3 Pitch:28°Azimuth:150° NEC 690.31 IC)to(NEC 316.16) Array 4 Rafter Size:2x8 Rafter 24"O.0 An6acdY va'Ovemunend WvlaConductor 90-CArca 4 Pitch:28°Azimuth:60° Conductor Ampacity Check 24.60 14.82 Conduit Fill Dorm 2 75.00 x 1.00 = 75.00 Y Conductor to Overcurrent Check 24.60 15.00 Temperah"Derat"'F 8795 7500 x 96 = 7200 Array 5 Rafter Size:2x8 Rafter 24"O.0 . Array 5 Pitch:14°Azimuth:240° AneaeRv w.owrcrwrant Device Avg.High Temp.:87_80 Use This Calculation for over current protection and wire sizing for Stringers coming from Cattluclor Ampacity Check 7200 52.08 — Rec.Low Temp:-9_4° Solar Panels.Get ISC from Product PDF ConOuctor10Owmu entChack 7200 60.00 i Input Date Into Yelbw Flelft Array info: Use This Calculation for over current protection and wire sizing for inverter. Module Weight(lb): 41.2 lbs. { Avg.Standoff Spacing(ft): 4'Max. input plate load ve6owFWds For use wiU 68rNOle throtler Cars I i Sign: I Date:09/21/2017 - ------------ PV-4 SIGNAGE REQUIREMENTS > RED BACKGROUND RE POWE > WHITE LETTERING BY SOLAR UNIVERSE > MIN.3/8"LETTER HEIGHT 210 Washington Ave Extension >ALL CAPITAL LETTERS WARNING Albany,NY 12203 WARNING >ARIAL OR SIMILAR FONT ELECTRIC SHOCK HAZARD.DO (518)213-8786 IF A GROUND FAULT IS > REFLECTIVE,WEATHER RESISTANT NOT TOUCH TERMINALS. INDICATED,THE NORMALLY MATERIAL,UL 969 TERMINALS ON BOTH THE LINE GROUNDED CONDUCTORS MAY AND LOAD SIDES MAY BE BE ENERGIZED AND LN ZED IN THE OPEN UNGROUNDED. 4 ";POSITION. 1 Linda Combs REQ'D BY: NEC 690.5(C) REQ' BY: NEC 690.14(C)(2) REQ'BY: NEC 690.14(C)(2) ��3 Queensbury,NY 12804 REQ'D BY:NEC 690.17 95 Montray Road i 4 APPLY TO: APPLY TO: APPLY TO: SMA AND SOLAREDGE INVERTERS DC DISCONNECTS IF UTILIZED AC DISCONNECTS APPLY DISCONNECTS SOLAR LOAD CENTERS System Spec: COMBINER BOXES System Type:Grid Tied Module Type:Hyundai HiS-S285RG • #of Modules:41 SYSTEM SIZE: _kW Inverter:SolarEdge SE1000OA-US w/ SYSTEM OPEN CIRCUIT VOLTAGE. _VDC Solaredge P300 Power Optimizer SYSTEM OPERATINNG VOLTAGE: _VDC PHOTO SO T • Racking:Ironridge XR100 SYSTEM OPERATING CURRENT VOLTAGE VDC -_ • Solar Mounts:S-5!Versabracket SYSTEM SHORT CIRCUIT CURRENT _AMPS AC CURRENT A STALL'� MAXIMUM ALLOWABLE , r AMPS DO NOT INSTALL ADDITIONAL • DC Waris:11.685 kW DC STC ... '. .. ,; SLAC Existing House Electrical: RED'Q BY: NEC 690.53 �1 REQ'D BY: NEC 690.54 r� REQ'D BY: NEC 690.64(8)(2) �� (E)Main Service Panel:200A oa Grid Voltage:120/240V APPLY TO: APPLY TO: APPLY TO: INVERTER PV SYSTEM BREAKER SOLAR LOAD CENTER IF UTILIZED Special Info: RoofTUPDATE VALUES UPDATE VALUES • Array Rafter Corrugated Metal Array 1 Rafter Size:2x8 Rafter 24"O.0 Array 1 Pitch:28°Azimuth:240° Array 2 Rafter Size:2x8 Rafter 24"O.0 F. WARNING • Array 2 Pitch:28°Azimuth:240° Array 3 Rafter Size 2x8 Rafter 24"O.0 WARNING' _. -' CAUTION ' ELECTRIC SHOCK HAZARD. FONNECTION. RTER OUTPUT -SOLAR PV SYSTEM MAY ':THE DC CONDUCTORS OF THE Array 3 Pitch.28°Azimuth:150° 00 NOT EMAIN ENERGIZED AFTER PV SYSTEM ARE Array 4 Rafter Size:2x8 Rafter 24"O.0 LOCATE THIS DISCONNECT DURING UNGROUNDED AND MAY BE • Array 4 Pitch:28°Azimuth:60° URRENT DEVICE DAYLIGHT HOURS. ENERGIZED. . Array 5 Rafter Size:2x8 Rafter 24"O.0 . Array 5 Pitch.14°Azimuth:240° Avg.High Temp.:87_8° REQ'D BY:NEC 690.64(8)(7) n REQ'D BY:AHJ n REQ'D BY:AHJREQ'D BY: NEC 690.35(F) 12 Rec.Low Temp:-9_4° 11 APPLY TO: APPLY TO: APPLY TO: UNGROUNDED ARRAYS ONLY PV SYSTEM BREAKER MAIN SERVICE PANEL SOLAR CONDUIT JUNCTION BOXES Array info: COMBINER BOXES Module Weight 41.2 lbs. DC DISCONNECTS • Avg.Standoff Spacing ing(ft): 4'Max. r PHOTOVOLTAIC SYSTEM "� INVERTERS PHOTOVOLTAIC MICRO' EQUIPPED WITH RAPID F• w' INVERTERS LOCATED UND SHUTDOWN.SWITCH IS THIS SERVICE IS SUPPLIED FROM EACH PV ROOFTMODULE OF ARR , ,I-.NTEGRAL TO THE INVERTER .. `,.MULTIPLE SOURCES UTILITY AND _ ,,. DISCONNECT. Sign: r ALPHOTOVOLTAIC REQ'D BY: NEC 690.56(8) (� REQ'D BY:NEC 690.14(D) n n Date:09/21/2017 MAIN SERVICE PANEL 34 APPLY TO: APPLY TO: MAIN SERVICE PANEL IF PV SYSTEM INVERTER UTILIZES MICRO INVERTERS PV-5 RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 xvwlYN.9�eenc,.rvfdM/en o.;o y Mulu-cryStiinlTypl l Linda Combs ^a 95 Montray Road -a-Mtia.., . ,Maaa.aPw Queensbury,NY 12804 Hyundai Heavy ludo ik wafpwsdad In 1972andn a intone 500 c npanµ3h.compMh•employs more than aB.WOMople and 1,as a 9h k "°•'9TOk� 9 1 batli,g]hutinesi d«wons with sales N 51.3&!H9n USD in 2013.K one M wr cae Ws'me,ses of the conpMy,Hyundai Hesvy YtluAriP.d i 30^'+�•d'•'t PatY 4:"11 19.1 4) co,mdned rodevebp a,M Iraest heady M the Midof mnavah4 er,e,gs•. 1 Owen Wan. a3lR .na"i 5uh'is the 6—,and[he lo,x)est awr,dkg Pv cN;and nn dub nvnulMtwe,k,Suu,h It—ft have wklW d nw an ldan capacity Mid prorid,hi91,­gua1fitysoMr W nodocts w na than 3.000 costnners vroridwke.We strive w Mhnv orc of tle efficient PV { CadsyPa ; skW urn+aN•alktu,�m PEKaedii°as°q UM1onW:dtrdatlem.9,e+i System Spee: m9dules by%tablishinganR&D laboratpy and lnves,ing mo,,the,A Mill—AD on innonOv whnobgks. j 168 System Type:Grid Tied ➢9p•raon¢e9aelmtMPa.F W/k -0AI wl Mt 3aamMaoer cul4mwim .,a e3: .2 a.3: Module Type:Hyundai HiS-S285RG • #of Modules:41 His-M65flG PERL Mmt265RG Iamnerype IHiS-M2]gflGIHiS-M2751IG I • Inverter:SolarEdge SE10000A-US w/ • Mono-crystal line Type IMono-"W.INrTyp.l Solaredge P300 Power Optimizer _. -Ser I H6s2e0fl1;His-s285flGlHls-529DRG �^� ' � � ro«- • Racking:Ironridge XR100 _.. � ..,. s?.v Solar Mounts:S-5I Versabracket 9 wMPm.m•9t ,w r »moo DC Watts:11.685 kW DC STC (unmtxPw,a lkgpq BA P.9 91 "°mmu9vlwl,l.womm(as]Mu.3snnu.3a�H, °+^°°� °�^� — .1 all Existing HouseElectrcal: APpov.I.Jk9 NLIIM) 9v:,°suamm. , 94 95 f.] —ell, wH (6,10 mandlw Ka whnology lH)n ,,H.Made In Korea) ° uoA �3 wOnn (E)Main Service Panel:200A mm'(,2AM)cables-1hp d dvrea0µ9prool connec,a,a. C.nwe b'Mwn eMa,a.rn,•rm nn,rrn tetb,mpItryuMaceR MadeM ltMraf Grid Voltage:120/240V IEC certified(Khted).tength 01(39,41 Metladeeeiaw�y1 '1, 1JR 121 IP6],rrosahe,ptoor IEC cent.ed IVt pstedl l byp diode, „M wSh •r°••'m'n° -0Ai -0.ai -0AI Special Info: imm:Anb,eneanrcaadnglm.-wnten�e,edga...x:rnmro.ua; n ,�.�+�*� ac oa .a+ wn • Roof Type:Corrugated Metal ErKaPsutm.WA Back SheN:w'eaMMpooEfihn II"I'� Cl Mr 9 lmdlal nim 11pyty, (elatkl n "„ • Array 1 Rafter Size:2x8 Rafter 24"O.0 IMialDiay I n-vewvesl Array 1 Pitch:28°Azimuth:240° 'N u Array 2 Rafter Size 2x8 Rafter 24"O.0 p (lollg Array 2 Pitch 28°Azimuth:240° dtn5(Ed2)ndlEC01730by9DE (Intl/ IIIDI�ID (�■' Array 3 Rafter Size 2x8 Rafter 24"O.0 uunik(DLII )Typelf Cla Fln,llMH,g Array 3Pitch:28°Azimuth:150° t3 • utput PPxe,tob.nce,3/-0,b I�I�I (IIID ...:: 15090D,300 jw 1aWl I00aand I50500D,10„eeadBed / ,..,. J _ Array 4 Rafter Size:2x8 Rafter 24"O.0 .p15A51BOD,.2a]CeHfed !® �DIIDfID IIIA '°a� _ ...m 4 Pitch:28*Azimuth:60* -Ad ..0Mecha lT,(9,000 Pa,Pa,ed(IEQ k, (' ® Arrayy 5 Rafter Size:2x8 Rafter 24"O.0 - /Meeh iloadT MOlbslk'I Passd(WI �� nlillllllll HIS .Ammon cn 9esmaaere3t=atw �` '"=•:•x i� �r ,n■ r I • Array 5 Pitch.14°Azimuth:240° •K•,0(SaO Mi < an Testi Pasted �, kllllllllill� '� mm Avg.High Temp.:87_8° �t!tt:z, ,,v,,,,,-,¢p �allf I111I1D ��+•�1 ��, .��� Rec.Low Temp:-9_4° aiIIIliII1111D1i11 •AHe.zna yeMolvkann9d eeyambon II�IIIII Array info: Bo29,fo.2syean D 1) '�–�j IHw�.�saBwr�w�el „c_2 • Module Weight(Ib): 41.2 lbs. Heae,efMtndeH,9EWanantylnm9redeail, liillllll (H � •o.+y..�eedP,.,n�teo�,ad..,taant+w,n,ma:.e„aR.. °3t Avg.Standoff Spacing(ft): 4'Max. 0lIIIIIDIIDIID j •ee ease[otdrRMar+siyl,pC ro.a.e. a Aadr9Eq •ponos danagea,oaY.A lbe veM w•6ce orthe madnk. pLm0YlU3 1m,vuMMra¢ �. ..�,...: ...n.n�., ..::n.•.. ...i.. •DonotivdewnsM9 m.odWe:wM,Uey art SA , ALHYUNDAI13. »w;.�'v4,,aPn, �9aaM« ,HYUNDAI Sign: HEAVY INDUSTRIES ,a.w2l+a w,,+aTs.xse t.w]]aa vers HEAVY INDUSTRIES Date:09/21/2017 Cutsheet— RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 solar • • Single Phase Inverters for North America solar' • • = Linda Combs sE3aaRRus sE3Ra 5 SESOOpA.US SEAMIOA-in SE—A-Us SE10000A-US st"il—Us 95 Montray Road aU,.UT Queensbury,NY 12804 SolarEdge Single Phase Inverters AC we — WX 7" ;�0� 114W VA Fia.4c vrArr cY✓M iiU� 4tbU 14 1six lOFV ,Y > tli50 1 AOO�zOAV 12UW vA For North America i95f"'° °a`'°#' AC o_VO4ge bk,,..Naa.AAa. , _ ,�"ms-n9v:Y System Spec: SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ A a nA a4„eNFA. 0".9 a - System Type:Grid Tied SE760OA-US/SE1000OA-US/SE1140OA-US 311"14o"e54v° • Module Type:Hyundai HiS-S285RG -a 1 s w..c.mmAren mu,4c.r4tlr. L:.s lc zs 32 <n eazoev Az.S t • #of Modules:41 aERrn wMw °'�z90Y • Inverter:SolarEdge SE1000OA-US w/ y F« ^A 1* �• �. mnc^ wn *^m°at Solaredge P300 Power Optimizer REvur >b,A,"n eawr.ssl« +oso Sluu b,so IuzSu Is35u w Racking:Ironridge XR100 �• prwar,rk».uw«ra.a P. i>W Solar Mounts:S-5!Versabracket Zvrtl "" Vac E- 3 DC 3 00 va` DC Watts:11.685 kW DC STC Hvn DC IMi1 Veb<8e 315 Qa 08V/50 U wV iv • t6.5°a zOAJ 33 N308V ""w °' e z4w F " 3o5024ov °' Atl' Existing House Electrical: ,..Invut sn,At Haan cm7rm 9 a Rr PowNh—, rv5 • (E)Main Service Panel:200A 6r a i°uF Nd'xa9l1r1erMYu 'k.�se"uHvrty fammt�,m.Lr erA.."ry 977 .F.z 9A3 9A 9F 3A ,s Grid Voltage:120/240V Cf(WrigI,IN ERLnRNY 91.5 9g g19i"1. 57.5 171 `--''S@2— s).5 .x 97 A•7AUv t?) NRNeAnr na...ca.v.++w•9.. .zs .° w Special Info: ® ApwrroRAEEEwTUREs Roof Type:Corrugated Metal wnwn•n r.�mm.arx",m,°n«.. AwAs u z EF°:�.zlRfl°.t"onmall RY.r"urc,aurp. s,uzl o w"r Array 1 Rafter Size:2x8 Rafter 24"O.0 snma---rats cseu r": • Array 1 Pitch:28°Azimuth:240° a _ _ sTANOlLRO COMOEMNCr pht - - Array 2 Rafter Size:2x8 Rafter 24"O.0 s,f V U 141 .111 L16 1948,CSA ll.3 n .wrn;rrs,:v�n. Ifrrral Array 2 Pitch:28°Azimuth:240° iccp,rtl5dh 8 Array 3 Rafter Size 2x8 Rafter 24"O.0 IRSTMUTION s•rcmC,Ui0115 • Arra 3 Pitch:28°Azimuth:150° 2 pC aulpa LdWu4 rre{Aw6 rs;hf /a mvumum/166 AWO /4 mum./tl-3 AWG y 1 pE byN,orYu4 sis/ROf strmRt/ 3/4 - um/l3swnRs/ — iFs Awe- FAQ. Array 4 Rafter Size 2x8 Rafter 24"O.0 3o.sxl:.sFTzlnst3r.3en 3p'11.31 lo.s/ vn.11 • Array 4Pitch:28°Azimuth:60° LLMY!p) 4 w,60 wwa'A wan s,h ysmtcro si,z/z3.r s4.>nAz ea a</4e.1 mArray 5 Rafter Size:2x8 Rafter 24"O.0 •, N,wral • Array 5 Pitch:14°Azimuth:240° _.. cooli"a Nar°„Ic9nr<ino” ,�eimrr"® f,":Ivstt.Enm<ramRl Avg.High Temp.:87.8° The best choice for SolarEdge enabled systems • Rec.Low Temp:-9_4° eWa.,w.l I � integrated art fault protection for NEC 2011690 11 compliance wyie <IS .5o nM Rapid Shutdown for NEC 2014690.12 p Mn.Onv'+•AR ir9nser lu:r .I3w.f40i:5wrfi0(4Uw+60 vresbn arMbgr"I t!,e Array info: Superior efficiency(98%) aovsnon RaF.q NEIWi 30. Module Weight(lb): 41.2 lbs. Small,lightweight and easy to install on provided bracket Built-in module-level monitoring _..w .v.�" ... Avg.Standoff Spacing(ft): 4'Max. Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage Inverter,DC/AC conversion only ` - Pre-assembled Safety Switch for faster Installation t" -Optional-revenue grade data,ANSI C17.1 �' Sign: 40 r,A _l;,v' r, I I<aaEi www SoiaLedge.u> �. Date:09/21/2017 Cutsheet RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 • solar' • • = solar' @ • � SolarEdge Power Optimizer Linda Combs Module Add-On for North America P300 i P320/ P400/ P405 95 Montray Road SolarEdge Power OptimizerP320 vaso P405 Queensbury,NY 12804 P300 11«60 call malar) IIor XIIx-power II°,17AE6Xlm Module Add-On For North America INPUT System Spec: Rated mpuz M Porti' 3(IU 320 Am 405 W P300 / P320 / P400 ! P405 • System Type:Grid Tied At_ar Ma.I.I.Mamyo:tagX • Module Type:Hyundai HiS-S285RG _ trot a Iowee.t Iemp¢ta e� 4e so us vex YP MPPT OPeralngR oge a-48 a-so 12.; 135 Vdf. #of Modules:41 Ma.—shone C'utemCbz) 10 11 10 Adz Is Inverter:SolarEdge SE10000A-US w/ �.r • Maximum DC input Currem 12.5 13.75 12.s Adz Mas—ER¢r.rty 99.5 Solaredge P300 Power Optimizer +'ti Welgntee e+a�enay sa.e cv-vooagecatey2,ry II Racking:Ironridge XR100 OUTPUT WMM6OPERATIONIPOEROPT,MIZERCONNECTEDTOOPERATING SOLAREDGE INVERTER( Solar Mounts:S-51 VerSabfaCKet W M.,;mwn 01—eaaery 15 Adr DC Watts:11.685 kW DC STC Marunvm 0.—Vatage w 85 Vdz _ OUTPUT WRING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREOGE INVERTER OR SOLAREDGE INVERTER OFF) sarnt uniw„va�p,te pa+Pows- I vd Existing House Electrical: • OPamae^ (E)Main Service Panel:200A STANMRD COMPLMMCE EW FCC Pa-5Cl's.a,IEC61000-62,IEC61000-6a • Grid Voltage:120/240V 2 8 '.faro IFC62109 1(classitsafetyl.UtlIsl I i,'... W S rn, Special Info: INSTALLATIDN SPECIFICATIONS Maximum Avowed System yovtage loco vdt Roof Type:Corrugated Metal Compatible lW.II.. al saarrdge Single Pna.e amrna IS2.e inverters Array 1 Rafter Size:2x8 Rafter 24"O.0 � '.28x152+Z]5/ 328.152x35/ 128x 152x 48/ Dinum Ions EwalaNl 5.5.97x].08 5x597.1.37 5.5.97,,1.89 in Array Pitch.28'Azimuth:240° weigh O'Ixhudn.C.!,el 770/17 '30/7.0' 9+0/70' gr/m Array 2 Rafter Size:2x8 Rafter 24"O.0 '.pine —I., MC4 Cu-nprnlb'e Array 2 Pitch:28°Azimuth:240° Output W've TVP./Cnnr— Double Inwlated,MC4 Comparable Output Wire tenah, 0.9513.0 1.2/3.9 Array 3 Rafter Size:2x8 Rafter 24"O.0 operanns Temperature RxnBe 40 .e5/-40-+195 / Array 3 Pitch:28°Azimuth:150° Pro lb-Rating IP68/NE MA6P Rebnpe NwnWrry o 1IX1 Array 4 Rafter Size:2x8 Rafter 24"O.0 Array 4 Pitch:28°Azimuth:60° Array 5 Rafter Size:2x8 Rafter 24"O.0 PV SYSTEM DESIGN USING SINGLE PRASE THREE PRASE 208V THREE PHASE 4a0V Array 5 Pitch:14'Azimuth:240° A SOLAREDGE INVERTER@ Mincmum snmgtrngth 3 to 1a Avg.High Temp.:87_8° IPorer Opnmi:ersr Rec.Low Temp:-9_4° Maximum Miring"'Oh PV power optimization at the module-level .s 25 so 6 IPowel Optilmzers) w Up to 2S%more energy Maximum Power per String S:So 6000 12750 W Array info: Daape3u""s wDdN" ""�^ ye. Module Weight Ib 41.2 lbs. w Superior efficiency 199.5%) I or Onenta g ( )' w Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading I ,,,,,,,•v„_,��,,, Avg.Standoff Spacing(ft): 4'Max. Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module level monitoring Module-level voltage shutdown for Installer and firefighter safety Sign: Date:09/21/2017 Cutsheet RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 DESCRIPTION: DRAWN BY: SNAPNRACK,STANDARD RAIL D.Ryan _ MID CLAMP ASSEMBLY Linda Combs REVISION -- PART NUMBER(S): f ( ` 95 Montray Road 232-01067,232-01068,232-01069,232-01070, Q Queensbury,NY 128 04 232-02112,232-02113 SSBONDING PON MODILE System Spec. i I FRAME System Type:Grid Tied Module Type:Hyundai HiS-S285RG I ) `RAIL / #of Modules:41 Inverter:SolarEdga SE1000OA-US w/ CHANNEL NUT Solaredge P300 Power Optimizer • Racking:Ironridge XR100 Solar Mounts:S-5I Versabracket NOTE DC Watts:11.685 kW DC STC I ADANSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND + i MODULES TO RAI Existing House Electrical: (E)Main Service Panel:200A 6.12 AWG BARE r5116--18 SS BOLT j, • Grid Voltage:120/240V COPPER WIRE I SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) Special Info: Roof Type:Corrugated Metal - 1.50 — SNAPNRACK _ GROUND Luc Array 1 Rafter Size:2x8 Rafter 24"O.0 .06 22 I 1Array 1 Pitch:28°Azimuth:240" 1.08 -'•� II Array 2 Rafter S¢e:2x8 Rafter 24"O.0 / CHANNEL NUT Array 2 Pitch:28°Azimuth:2400 1 1 _ Array 3 Rafter Size:2x8 Rafter 24"O.0 22 .15 ` ------ r . Array 3 Pitch:28°Azimuth:150° Typ 1.50 07 ss BONDING RAIL Array 4 Rafter Size:2x8 Rafter 24"O.0 �1 PINS _ Array 4 Pitch:28°Azimuth:60° STANDARD RAIL PROPERTIES 7.50 //- 1 I Array 5 Rafter Size:2x8 Rafter 24"O.0 SKU RAIL LENGTH(X) FINISH t j T1pALL I1ARDWARE ig INCLUDED FROM MANUFACTURER Array 5 Pitch:l4°Azimuth:240° 232-01067 122" BLACK�', I 232-01066 122" CLEAR'�. 1.06 f z.AMINIAl1M OF ONE GROUND LUG IS TO BE IN ON EVERY Avg.High Temp.:87_8° 1 232-01069 162' BLACK 1,44 1.08 CONTW XXIS ROW OF MODULES Rec.Low Temp:-9_4° ' CLEAR .22 3 GROUND LUG MAY BE INSTALLED N EITHER RAIL CHANNEL 232-01070 162: 22' MILL , 4.GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR 1 T ASgeLeIEA PERPENDICULAR TO RAIL Array 232-02113: 162" MILL T L 1 5,ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE . Module Weight(lb): 41.2 lbs. u 15 .22 � • Avg.Standoff Spacing(ft): 4'Max. ALL DIMENSIONS IN INCHES - - -- 1 MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL OPTIONS: DESCRIPTION: SAWN�' MIKE WATKINS (� SNAPNRACK MOUNTING SYSTEM APPRBY: m O— or NORMAN Snap�ack DESIGN LOAD(LBS): N/A CLEAR/BLACK ANODIZED GROUNDING DETAILS G_W NEW tIEN Saw II" �sobdion ULTIMATE LOAD(LBS): N/A MILL FINISH _. Sign: I TORQUE SPECIFICATION: N/A LB-FT 122"/162"LENGTHS - SINmwISaX1X LLC 0 g PMT NUMBER. SCALE: a,m.r ..w...ss.mur. w CERTIFICATION: UL 2703,FILE E359313 BOXES OF 2/6 •wr.,•.•.•�.M:'�••• WEIGHT(LBS): 7.65-10.16 BUNDLES OF 112 DNS — Date:09/21/2017 Cutsheet RE POWER BY SOLAR UNIVERSE 210 Washington Ave Extension Albany,NY 12203 (518)213-8786 S=510 J The Right Way! Linda Combs VB-67 V1347 Versa Bracket-67" VersaBracket-47" 95 Montray Road Queensbury,NY 12804 VB47 vB47 System Spec: System Type:Grid Tied "- Module Type:Hyundai HiS-S285RG " #of Modules:41 Inverter:SolarEdge SE10000A-US w/ Solaredge P300 Power Optimizer Racking:Ironridga XR100 •—- a` Solar Mounts:S-5!Versabracket 4 ; 6. VersaBracket'•" • asked • _+�,,, may, ,",,,, Dc watts:1 t685 kw DC STC ,. `fit,. u.� ,s VersaBracket'"can be used to mount got Nowattach the - I almost anything to an exposed- anwanw.+�a.aamw°a"c.mannmayra.xn.b."..emw,..a. Existing House Electrical: fastened roof system and is compatible (E)Main Service Panel:200A with almost any trapezoidal exposed- • • Grid Voltage:120/240V fastened profile.No messy sealants , "r`o accommodate various rib heights.VersaBracket"'comes in two heights—the 2.65` to apply! No chance for leaks!The 1 VersaBracket-67'"and the 1.86`versaBracket-47^'-The VersaBracket-671"mounting face VersaRracketl"comes with factory- il • r - / has no holes or slots,thus,ancillary items are typically secured using self-tapping screws. Special Info: applied butyl sealant already in the has •• The VersaBracket-47-offers various mounting face configurations with minimum purchase Roof Type:Corrugated Metal and the 5-51 patented reservoir conceals , es , requirements.(Contact your distributor for available configurations.)Each VersaBracket*"comes Array 1 Rafter Size:2x8 Rafter 24"O.0 the sealant from uv exposure,preventingI with factory-applied butyl sealant in the base.A structural aluminum attachment bracket, drying and cracks. exposed-fastened VersaBracket'"is compatible with most common metal roofing materials.For design assistance. Array 1 Pitch:28°Azimuth:2401 metal roofing with the I ask your distributor.or use our web based Array 2 Rafter Size:2x8 Rafter 24"O.0 LInstallation is simple!VersaBracketlN calculator at—s-S.eom for job-specific y y Array 2 Pitch 28°Azimuth:240° =mounted in the flat of the panel, system engineering and design of your next Qv directly into the supporting structure snow retention project.Also please visit our s .�a Array 3 Rafter-Size:2x8 Rafter 1 O.0 of the roof,i.e.wood decking,wood or steel purlins or trusses-No surface website for more information including CAD a 3" Array 3 Pitch 28°Azimuth:150° preparation is necessary;simply wipe away excess oil and debris,peel the details,metallurgical compatibilities E ..` �, Array 4 Rafter Size:2x8 Rafter 24"O.0 release paper from the base,align and apply.Secure through the pre-punched and specifications. holes using the appropriate screws for the supporting structure. " Array 4 Pitch:28°Azimuth:Rafter ''(''he VersaBracket"'has been tested for load-to-failure results on wood Array 5 Rafter Size:2x8 Rafter 24"O.0 Versallracket—is so strong,it will even support heavy duty applications 1 decking,metal and wood purlins.The independent lab test data found Array 5 Pitch:14°Azimuth:240° like snow retention.For exposed-fastened trapezoidal profiles,the at wt—S-S.com can be used for load-critical designs and applications.5-5 Avg.High Temp.:87_8° VersaBracket-is the perfect match for our ColorGard`or RamGard"snow holding strength is unmatched in the industry. retention systems(For corrugated roofs use CorruBracket—).VersaBracketlN Rec.Low Temp:-9_4° is extremely economical and facilitates quick and easy installation. N-ersallracket"'is versatile!It can be used for almost any S-5-PV Kit(DirectAttached—or Rail) RatnGard"" ColorGard- attachmentneed, , , ,, , , , on all types Array info: of r t •r •t t tr t n• t r Module Weight(Ib): 41.2 lbs. Avg.Standoff Spacing(ft): 4'Max. if 4 . t . . . r rwaterproofsi t 1 � ss+..�srr.....irw r.�a•.srMwwr' 0oldbided by Sign: 888-825-3432 www.S-5.com "" 0'0210 Date:09/21/2017 Cutsheet-11 296.13-1-80 SOLAR-000664-2017 Combs, Linda 95 Montray Road Solar Panel System (no upgrade) R POW TM OBY SOLAR UNIVERSE UNY POWERED BY THE AEC GROUP OF COMPANIES Utility Agent of Authorization I, Linda Combs, Authorize Peter Fabrykiewicz/Randy Savage/Renee Dufek/Nicole Castelle of American Energy Care (AEC), Solar Universe (SU), and Hollitronics Energy Solutions Located at: 210 Washinaton Avenue Extension Alban, New York 12203 To act as my agent for the installation of my utility interactive photovoltaic system, which is to be installed at: 95 Montray Rd Queensbury, NY 12804 This allows the authorization of building/electrical permits and necessary change orders. My Utility Account is: 85952-50103 Signed: Date: 4�gS ENGINEERING P. C . Structural Design,Inspection,and Analysis October 12,2017 D E C E 0Ms. Renee Dufek Solar Universe UNY OCT 2 4 2017 210 Washington Ave., Ext. Albany,NY 12203 TOWN OF QUEENSBURY BUILDING R CODES Re: Report for the Structural Analysis of the Photovoltaic Installation at the Combs Residence Located at 95 Montray Road in Queenshury, New York. (17005.35) Dear Ms. Dufek, As requested, Shamrock Engineering P.C. has performed a structural analysis for the support of the proposed Photovoltaic(PV) installation by a portion of the_residence at the above referenced address. As agreed to,the analysis was performed for the purpose of determining whether or not the existing building is capable of supporting the loads imposed by the proposed installation. This letter presents the findings and conclusions of our analysis. Prior to commencing work, we were provided a description of the panel installation and documentation of the existing structural components. Original construction drawings for the building were not available for our use. From the data provided and collected, the building is a wood framed structure constructed with dimensional lumber rafters and perimeter bearing walls. The rafters are 2x8 lumber spaced 24 inches on-center and support roof decking and metal panel roofing. Solar Universe proposes a PV configuration that will require the installation of 54 solar panels. The panels will be supported by industry standard roof mounts, which will attach directly to the roof rafters. The support system design and roof analysis were performed for support of the Code defined 60psf Ground Snow Load and 115mph Ultimate Wind Speed. Based on the information provided,our analysis indicates the roof framing and bearing walls are adequate to support the weight of the proposed panel system and the roof loads provided the following conditions are met. The rail support feet shall be staggered in order to anchor to each rafter and must have a spacing not exceeding 48". If you have any questions, please call. Sincerely, 296.13-1-80 SOLAR-000664-2017 Sharnro Combs, Linda 95 Montray Road >t ichael J. K 0 Solar Panel System (no upgrade) President -S5�°�' 1 Thrush Terrace East Greenbush, NY 12061 Ph: 518-441-6148 Fax: 518-286-2978 email: mkenneally@shamrockengpc.com