RC-000692-2017 TOWN OF QUEENSBURY
fT
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000692-2017 Date Issued: Tuesday, August 28, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000692-2017
has been completed.
Tax Map Number: 296.13-1-55
Location: 147 MONTRAY RD
Owner: STEPHANIE SMITH
Applicant: Burke Bros. Builders,Inc.
This structure may be occupied as a:Residential Alterations (due to fire) 1255 s,
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
4
property owner of the responsibility for compliance with Site Plan, .vf
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000692-2017
Tax Map No: 296.13-1-55
Permission is hereby granted to: STEPHANIE SMITH
For property located at: 147 MONTRAY RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvne of Construction
Owner Name: STEPHANIE SMITH Single Family-Alteration $200,000.00
Owner Address: 147 Montray RD Total Value $200,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Burke Bros.Builders,Inc.
PO Box 105
Lake George,NY 12845
Plans&Specifications
Residential Alterations(due to fire)1255 s.f.
$188.25 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 2,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury beforejdmiee 'ration daDated at the Town o ueensb4Thukovember 2,2017
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Oniy
ADDITION/ALTERATION PERMIT Permit#: Oc.- (9�2- - 2,(D l�-
' APPLICATION Permii Fee: $ 1`$b•25
Toon of(Lucensburc-
742 Bay Road,Queensbury,ivy 12804 Invoice#: 38
t':518-761-8256 www.gueensbury.net
E0
Project Location: _1 4 i (zJ E D v
D
Tax Map ID #0 1-W. lav- l-`� Subdivision Name ► �g����
CONTACT INFORMATION'
TOWN OF OUBBNSB
URY
BUILDING&CODES
® Applicant:
Name(s): ��>— , T�f c
Mailing Address, C/S/Z: R•o F,. K L--o" N� ('�L(; 14
Cell Phone: ( ,U b ) `7J(, - 0 3 ;;k-ef Land Line: sib GG 6 • 3 d S 1(
Email:—Q-,-N io sr -s . b b b r k-o-t l . C. w"
Primary Owner(s): ,'1r
Name(s): S W� t
Mailing Address, C/S/Z: 'I (ylo of , NV
Cell Phone: Land Line:
Email: r- S C i 6@ coo . Com•
• Contractor(s):
BusinessName:
Contact Name(s):
Mailing Address, C/S/Z: J. C3,;x 3 Q„ ti �.�`,��, My lad l `f
Cell Phone: ( !Vb_) -i q ko '0 3 Land Line:
Emai(:_ C�v.bux-ice C°' Q rv.r�.E l . C�w•
® Architect(s)/Engineer(s):
Business Name: LA- j�j 6 o`s
Contact Name(s): �,"_�{- b,4 b wS
Mailing Address, C/S/Z: A be- i21.-� NY llmq
Cell Phone: (SZ ) SDS - S q land Line: ( 51 6
Contact Person for Building & Code Compliance: ( v'-
Cell Phone: ( Sly ) `l q k6 Land Line: ( Slb )
Email: co n.,
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
PROJECT INFORMATION,
TYPE- Commercial /\ Residential
WORD CLASS:
Single-Family _Two-f=amily Multi-f=amily (#of units )
Townhouse Business Office Retail
_ Industrial/Warehouse _Garage (# of cars ) Other (describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE°
1st floor: 1st floor:
2" floor: 2nd floor:
3rd floor: 3rd floor:
4th floor: 4th floor:
Total square feet: Total square feet-
ADDITIONAL PROJECT INFORMATION-
1. Estimated Cost of Construction: $
2. If Commercial project, what is the proposed use: la`
r-
3. Source of Heat (circle one): � as Oil Propane Solar Other
Fireplaces need a separate F urning Appliances & Chimney Application
4. Are there any structures not shown on the plot plan? YES (jN� Explain:
5. Are there any easements on the property? YES (�
6. SITE INFORMATION:
a. What is the dimensions or acreage of the parcel?
b. Is this a corner lot? YES
c. Will the grade be changed as a res of e construction? YES
d. What is the water source? PU LIC PRIVATE WELL
e. Is the parcel on SEWER or PRIVATE SEPTI ystem?
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
UECLAR ZION:
1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: UN � ter tC--4e
SIGNATURE: DATE: 11-2 -17
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
REScheck Software Version 4.6.4
c _£ Compliance Certificate o C6
N L0
L0
04
07 �
CO
Project Smith Residence o
0
0
Energy Code: 2015 IECC C1 C
Location: Glens Falls,' a �r� tY O
Construction Type: Single-fami CU U N
Project Type: Alteration = I0
Climate Zone: 6 (7635 HD u NOV 0 2 2017 a
Permit Date:
Permit Number: TOWN OF QUEENSBURY r C/) C
BUILDING&CODES M o a
Construction Site: Owner/Agent. Designer/Contractor: T— ,� 2
147 Montray Road Stephanie Smith Curtis Dybas (1i
Queensbury, NY 12804 147 Montray Road 19 Deer Run
Queensbury, NY 12804 Lake George, NY 12845 N U)
518 668 5591
cdybas@yahoo.com
Compliance: Passes g prescriptive requirements for alteration projects
Envelope Assemblies
Gross Area
Assembly or Cavity Cont. U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 1,248 19.0 19.0 0.026 32
Wall 1: Wood Frame, 16" o.c. __- ___ ___
Exemption: Framing cavity filled with insulation
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 283 0.310 88
Door 1: Solid 59 0.077 5
Door 2: Glass 84 0.500 42
Basement Wall 1: Masonry Block with Empty Cells 1,255 0.0 15.0 0.046 58
Wall height: 7.2'
Depth below grade: 6.3'
Insulation depth: 7.2'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listethe REScheck Inspection Checklist. f
nX05; 1 . 1�`i�,b!G- � l l t/02 x201
Name-Title Signature Date
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 1 of 9
CREScheck Software Version 4.6.4
�(J Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1)1 energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3)1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: [ Complies
:403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2)2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods Btu/hr Btu/hr ❑Not Observable
approved by the code official. ❑Not Applicable
I
i
I
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 2 of 9
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID _ _
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
(FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
-----------------
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions. ❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a ❑Not Observable
minimum of 6 in. below grade.
_ ❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12]2 controls installed. []Does Not
❑Not Observable
_ ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID _ ---- - — — - -
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR111
❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. []Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable
_ ❑Not Applicable
402.4.3 Fenestration that is not site built _ ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC []Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate s2.0 cfm
leakage at 75 Pa. []Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_
R-6 where <3 inches.Supply and []Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
_for< 3 inches in diameter. _
403.3.3.5 Building cavities are not used as _—v — ❑Complies
[FR15]3 ducts or plenums. []Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies —
[FR17]2 above 105 QF or chilled fluids ❑Does Not
3, below 55 QF are insulated to zR-
❑
3 Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
_ ❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
_ ❑Not Applicable
403.6 — Automatic or gravity dampers are— ❑Complies —
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 4 of 9
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C;\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 5 of 9
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- _❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood []Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass
[IN3]1 exterior,the exterior insulation ❑Not Observable
requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
[Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling Insulation R-value. R- — R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, Steel Steel []Not Observable
402.2.6
[Fill' ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every
300 ft2. []Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation >R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
--- --------------- --------- ------------ ---------
402.4.2 Wood-burning fireplaces have ❑Complies
[F[8]2 tight fitting flue dampers and ❑Does Not
outdoor air for combustion.
❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies —
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handier @ 25 Pa.For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handier
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated — ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow. ❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[Fl9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
_ code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 7 of 9
Section
Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.5.1 Circulating service hot water ❑Complies
(FI11]2 systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
[]Not Applicable
403.6.1 All mechanical ventilation system ❑Complies A
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor [Not Applicable
temperature.
403.5.1.1 Heated water circulation systems u ❑Complies
(F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically
adjust the energy input to the [--]Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that s ❑Complies
[F130]2 have recirculation pumps that []Does Not
pump water from a heated water
supply pipe back to the heated [:]Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
855.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for []Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI6]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. []Not Applicable
rl �High_Impact(Tier 1)� 2 Medium Impact(Tier 2) �3 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 8 of 9
�( 2015 IECC Energy
j Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 0.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.31
Door 0.50
CoolingHeating&
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
404.1.1 Fuel gas lighting systems have ❑Complies
[FI23]3 no continuous pilot light. ❑Does Not
as:
[]Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies
[FI7]2 ❑Does Not
❑Not Observable
_ ❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
[-]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Smith Residence Report date: 11/02/17
Data filename: C:\Users\Curtis\Documents\REScheck\Smith residence fire rebuild.rck Page 9 of 9
/ Sep. 17. •2018•; •1 •40P .MDIA,.-. _ ,,;,_ ,:.. t., No. 5061 P, 5/18
.l=✓.✓•` i. \ ,,Ce'Jj_•::`.''••y`�•" «jam'\�CY�
' '' MIDDLE DEPARTMENT INSPECTION AGENCY, INC. za
c, i
4l% that the electrical wiringto the electrical(`� � equipment listed below has been examined and is approved as �%'��
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date ��`�.
c noted below and is issued subject to the following conditions. \:
\>> Owner: Stephanie Smith Date: 08/27/2018 ~':
<< Occupant: Same Locationt
; 147 Montray Road ,.
- Occupancy Queensbury,Warren Co. NY '%
y Single Family Dwg. �.,�
Vie, Applicant:
•,. William Bartholomew <:,
%� 80 Brampton Road
� Ganesvoort, NY 1283.1. - • • - . .I.
• ,L J ;\
Joseph A.Holmes. . ,- ,
?) No. - - - •0327081361581 EL• _ ' '_ .`:.._ • •_ . . �;
'c•; Equipment: ,
200-Amp. Service Equipment 4/0-Service Conductor, 52•.-Switches; 74-Receptacl•
• es; 58-Fixtures; 1 -30 Amp ;\?
(�a Air Conditioner; 1 - Burner,Wiring & Control For Gas; 1 - 15 Amp Dishwasher; 1 -30 Amp Receptacle; 3-Vent Fans; re4
'7-Smoke Detectors; 17-:Arc Fault Breakers C%
•
•
fie:) ,(..
. �,
'Vil H
'$
�
wiring (
\ ing to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and \:&
ig This certificate applies to the electrical above and the installation inspected as of the above noted data based on a visual ownership as indicated herein. Upon a change In the use,occupancy or ownership 'rr>l
k.i inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. 7C;
(�) ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, r
be valid for a period or one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department V%.
-9 system to which this certificate applies be altered In any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle rid
j) ad to.the introduction of additional electrical equipment anWor the replacement of Department Inspection Agency. Inc.to initiate the inspection and revalidation (('.
any of the components Installed as of the above noted date,this certificate shall be process. A lee will be charged for thta seMce,
;<. .ri%;!-:ii , , %%:,*%.f.;i ..!:.;l:; ;;;/, 5. :•:i:•: `. ,_f? \i:`-f%;- '`;%. i.\;q;,7i.^>,;<- ;-:/', `GX\% %:•%.1 ;; • ': i:.x .
C-C - 1CF2 1,0,19•-
+ ,----; I w /r_ ;7 I I • ,i ire ',; ;
i I I' .a 4�JJ L'-•9 LJ ... 1 I'1
ij i{ i
I
lti SEP 1 $ 2018 li
i
. i.
i TOWN OF (.)UEi...N•'t iJems,y i
I .....,--...�1 EVt_7- ...—,...--._' i