RC-000696-2017 i
TOWN OF QUEENSBURY
742 Bay Road,Queensbury, NY 12804-5904 (518) 761-8201
Community Development- Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000696-2017 Date Issued: Thursday, May 17, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000696-2017
has been completed.
Tax Map Number: 301.17-3-50
Location: 3 CAITLIN DR
Owner: Laura Collette, Ken Collette
Applicant: Kelaco, LLC
This structure may be occupied as a: SFD w/gas FP 1814 s.f.
Garage 524 s.f. By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the �j /�
iot
property owner of the responsibility for compliance with Site Plan, ( j
/�
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
a
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000696-2017
Tax Map No: 301.17-3-50
Permission is hereby granted to: Collette Construction Inc.
For property located at: 3 CAITLIN DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tyne of Construction
Owner Name: Laura Collette Single Family-New $265,000.00
Owner Address: 35 Front ST Total Value $265,000.00
Lake George,NY 12845
Contractor or Builder's Name/Address Electrical Inspection Agency
Collette Construction Inc.
38 Collette LN
Hudson Falls,NY 12839
Plans&Specifications
SFD w/gas FP 1814 s.f.
Garage 524 s.f.
$1,341.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,November 20,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of een / Ion ,N 20,2017
SIGNED BY: //aJ for the Town of Queensbury.
Director of Building&Code Enforcement
-ffice Use Gni%% i
U E iiiit#: f? —
lei L0�.[�
I I AN�IND 3 207 ermit Fee:$
Rec Fee:$ U. vU
742 Bay Road,Queensbury,NY 128 TO OF QUEENSBURy
P:518-761-8256 e f,t -.- //``BUILDING& CODES
Invoice#:
Project Location: 3 c4,U,,,nJ Ue.-
Tax Map ID#: !ze! � o — /—5-0 Subdivision Name: 1 a L•t11� P 'UP S
*TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units: single family,duplexes/two-family.
multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile
homes. This Is In addition to the permit fee(s).
CONTACT INFORMATION:
• Applicant:
Name(s): � -
Mailing Address, C/S/Z: 21 'n�,r-sf" . `P (5eo>E /I, V
Cell Phone: J —) `� 6 S' Land Line:
Email:�L ,e ,1 i�r�^r ( /!P 77r,
• Primary Owner(s):
Name(s): oYZ 4 (�!i Me/r
Mailing Address, C/S/Z: 3 S'�k,,?
Cell Phone: (S-4-_)_ Land Line:) 46 2
Email: 7A y E
• Contractor(s):
Business Name: Ce��It di C6At %A(1 17*1 n
-
Contact Name(s):_L.o,v (I/ft t6r
Mailing Address, C/S/Z: . /fie//7p- f 3
Cell Phone: f�� ) 1 6' 5' Land Line: „ 5`'� )�Q/C - 112-0
Email: S/:
• Architect(s)/Engineer(s):
Business Name:
Contact Name(s): F-cP <—,gP6;,4, 02 � `/zy
Mailing Address, C/S/Z:
Cell Phone: �_) Land Line: ) 7 22- /33 G
Email:
Contact Person for Building& Code Compliance:
Cell Phone: � ) 36S" 5�5�L-2 Land Line: � _) 7y I/10
Email:
Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017
PROJECT I
NNFORMATION:
TYPE: &S i Q'�I Commercial id
WORK CLASS:
,Single-Family _Two-Family _multi-Family(#of )
Townhouse Business Office rRetail —Hotel/Motel
_ industrialMarehous2 Garage(#ofcars Other(describe )
STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE:
1sT floor: �1 15T floor. 6 �q
2"d floor: :��
2nd floor:
3rd floor: Total square feet:
41'floor:
Total square feet: if
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ 4 C
2. Proposed use of the building:
3. If Commercial or Industrial,indicate the name of the business:
4. Source of Heat(circle one): Gas Oil Propane Solar Other:
(Fireplaces need a separate Fuel Burning Appliances&Chimney Application,one per appliance)
5. Are there any structures not shown on the plot plan? YES '�.`�."J Explain:
6. Are there any easements on the property? YES
7. SITE INFORMATION:
a.What is the dimensions or acreage of the parcel?
b. Is this a corner lot? YES NO
c.Will the grade be changed as a result of the construction? YESO�
d.What is the water source? PUBL 0 PRIVATE WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? ipgwe- r stpf_C_
Townof Queensbury Building&Code Enforcement Principle structure Appiratlon Revised February 2017
DECLARATION:
1. 1 acknowledge that no construction shall commence prior to issuance of avalid building permit and
work will be completed within a 12 month period.
2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed 1, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: GIA Mf
SIGNATURE: � � DATE: "O-? n
Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017
Town of Queensf ury
Michael F. Travis
Highway l ghivery Superinterrderrt
Horne: (518) 798-()413
Department
742 Bay Read Queensbury,NY 12804 Thomas R. Vanness
I�e�xety Superinteraderzt
Office Phone: (518) %(>1-b'211 Hortre (51b) %45-0929
FU.x-: (518) 7454466 DRIVEWAY PERMIT
www.yueensbuq%net
DATE: -I 7
APPLICANT NAME: Co �CQ/rT <N5�
TELEPHONE NO.:
ADDRESS TO BE INSPECTED: 3 DR
RETURN ADDRESS: 3S_ C6f/C L_A, k
Applicant must show exact location and width of driveway(s) to be connected to the highway by
placing stakes at the specified location.
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The
following action has been taken:
STEP 1: ( ) Preliminary Approval
NEED: ( ) Slight swale
( ) Deep swale
( } Level with the road
( ) Level with the top of the paved wing
Size culvert pipe to be used (if necessary)
( )12" ( )15" ( )18" ( )24" ( )36"
Preliminary inspection completed by: Date:
Approval by Highway Supt: Deputy Supt:
Upon completion, please resubmit this approved permit for a final: approval.
STEP 2: ( ) Final Approval
( } Rejected
Date:
Michael F. Travis, Highway Superintendent
Thomas R. Van Ness, Deputy Highway Superintendent
Fire Marshal's OfficeIM AW
;
1Ci U t }` 47 rf ee f t 5,b l t r i/" 742 Ray Riwd " liieei4 tfry, ;",ca) 'Y ork -128;'.4
Mickacl f.1'alincr, vire Alarslrnl• Gari/Still,man,I'elrlrt;/Eire Alarshin,
,
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit
pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances,regulations, and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS AR//E''REQUIRED. ,
OWNER: ��H 1 C> INSTALLER/BUILDER: (0 �//P-/!'�
ADDRESS: 3� �2ffC/C' 12P''(S ADDRESS: 76 re)/-�P//F- �'F
PHONE NOS. 5'I�' G(i,5-aS �1T P_ PHONE NOS. S /� 3 7
65 '6 ��
LOCATION OF PROPERTY: 3 Q//t t N N f, SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: .
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: Imp/-% PHONE:
✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE, FACTORY BUILT*
FIREPLACE,MASONRY
FURNACE(GARAGE ONLY) //
*IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: N xtr(SID MODEL NO.
LISTED BY: NUMBER:
QUESTIONS?
CALL 7614205 or 761-6206
CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL:
MASONRY" CHECK ONE ✓ VISIT OUR WEBSITE
TILE STEEL SIZE IN FOR MORE INFORMATION
INCHES _
FLUE CHECKONE ✓
DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CHECK ONE ✓
**IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. .3 ry
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
• i'....."""""....""'...........""'...................................... .........................
OFFICE USE ONLY '% %
, .
,
TAX MAP NO. PERMIT NO. PERMIT FEE % %
APPROVALS: ZONING TOWN CLERK , % 11
ol
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID
PERMIT. l y
OWNER: KQ 1Ac- INSTALLER:
�� y�
ADDRESS: 3S 1 L p-mr S� L- �, 1 d?9Y ADDRESS: � �1 N�/ �.,fJ, 1Y. 1 kiN
PHONE NOS. i/,P 6b F' Sal - V4 ff a2- PHONE NOS.
LOCATION OF INSTALLATION: 3 0&
NO.OF RESIDENCE INFORMATION:
YEAR BUILT X COMPUTATION= = TOTAL DAILY FLOW
BEDROOMS GARBAGE GRINDER
1980 or older X 150 gallon per bedroom = INSTALLED?
1981 -1991 X 130 gallon per bedroom =
SPA OR HOT TUB
1992-present 3 X 110 gallon per bedroom = 336 INSTALLED? Aj Q
PARCEL INFORMATION:
✓ TOPOGRAPHY: Flat rolling c/ Steep slope %Slope
✓ SOIL NATURE: Sand r/ Loam Clay Other
✓ GROUNDWATER: At what depth? Ir r
✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth?
✓ DOMESTIC WATER SUPLY: Municipal //-- Well (If well: Water supply from any septic
system absorption is ft.)
✓ PERCOLATION TEST: Rate is D- S" minutes per inch [MPI]
(Test to be completed by a licensed professional engineer or architect.)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by
a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision).
TANK SIZE: UC) GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for
each garbage grinder, spa or whirlpool tub.
SYSTEM TYPE:
Lief' ABSORPTION FIELD (WITH NO. 2 STONE) Total length-21-0-tft. Each trench 3 X �"n _
❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size?
❑ ALTERNATIVE SYSTEM Bed or other type?
❑ HOLDING TANK SYSTEM Total required capacity?
Tank size? Number of tanks?
NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN I
APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. '
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any
permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or
failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.
C E 9 W E
D
MAY 17 2018
'OWN OF QUEENSSURY
BUILDING&CODES
..",•un'LALN wr„SLI M ELECTRICAL INSPECTION SERVICE:,INC
Main Office 176 Doe Nun Road r Manheim,pA 17545
MUNICIPAX, CER'T'IFICATE - ELECTRICAL,APPROVAL
N
Q
Permit No. 42
Owner. ............ ................................cert. w 386 Cut-r11 Card No......
..,...... ... ... .........
,,,,,,,,,,,,,
..
......
.....Lotion .........
1..1..4l.l�.......p.
Installation Consisti `
csf o�.S7Sln"1
"� - .. �.. ,....,..,.,.,. .
4.1..............................----
[ttstalled B •••••...
................................... ....Lic. Nn.
............................................
The conclinvr%c following governed the is
Cancelled;-
suance of chis ccnificste,tutd acct'certificate previously,ssuccl is
This ccrtifea(c only covcl�, tlle dcc[
introduction Of rical equipment and insinllat'on eon ditiocts as of date. Upon the
atJit;octal et�utp�t+Ct1t or alleralions,application shall be ptmnptly made for irespecrion,
InspcctOr6 of this Company shall have the privilege of making ictsFuceions at any time, and if it,
rules arc violated.the Gonrpany shall have the right to revoke this certificate.
Date--
.................. inlSrEC'rtDR,,,,S,�r,,,_ f '
Meinber N"EP.q„
10 39VH n7s7wnw wnx hacrac,) I to-c,ta s�ra7 ii t rcra
REScheck Software Version 4.6.4
Compliance Certificate
NE
Project Collette Construction C Home ��� !-
NOV 0 3 2017 ,��� ®� D. � �M
Energy Code: 2015 IECC �� CO
Location: GI aIs, New York TOWN OF QUEENSBURY
Construction Type: Single-family
Project Type: New Construction BUILDING&CODES
Orientation: Unspecified -
Conditioned Floor Area: 1,816 ft2 6
Glazing Area 11%
Climate Zone: 6 (7635 HDD)
Permit Date: f I
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
3 Caitlin Drive Kenneth Collette Kenneth Collette
Queensbury, NY 12801 Collette Construction Collette Construction
39 Collette Lane
Hudson Falls, NY 12839
518.746.1120
information@colletteconstruction.c
om
Compliance: 2.7%Better Than Code Maximum UA: 264 Your UA: 257
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
oss Area
em y or
Perimeter
Ceiling 1: Raised or Energy Truss 944 38.0 0.0 0.025 24
Wall 1:Wood Frame, 16" o.c. 2,246 21.0 0.0 0.057 111
Orientation: Unspecified
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 206 0.270 56
Orientation: Unspecified
Door 1: Solid 56 0.100 6
Orientation: Unspecified
Door 2: Glass 42 0.270 11
Orientation: Unspecified
Basement Wall 1: Solid Concrete or Masonry 1,096 19.0 0.0 0.045 49
Orientation: Unspecified
Wall height:7.8'
Depth below grade: 7.0'
Insulation depth: 7.8'
301.17-3-50 RC-000696-2017
Kellam LLC
3 Caitlin Drive
SFD w/FP 1814 s.f., Garage 524 s.f.
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3Caitlin Drive.rck Page 1 of10
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
RESchecck Version 4.6.4 and to comply with the mandatory requirements listed in the flEScheck Inspection Checklist.
FAC
Name-Title Signatur Date
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3Caitlin Drive.rck Page 2 of 10
CREScheck Software Version 4® .4
�J( Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section _ Pians Verified Field Verified '
# Pre-inspection/Pian Review VaiueVaiue Complies? Comments/Assumptions
& Req.ID _
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ° ❑Not Observable
'envelope represented on ❑Not Applicable
construction documents.
103.1, ;Construction drawings and ❑Complies
103.2, 'documentation demonstrate ❑Does Not
403.7 !energy code compliance for
[PR3]1 'lighting and mechanical systems r ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302:1 Heating and cooling equipment is Heating: : Heating: ❑Complies
403:7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[0112]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods Btu/hr Btu/hr ❑Not Observable
y approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3)
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3Caitlin Drive.rck Page 3 of 10
r Seton ' ro r t:or� Inspection Plans Verified Field Ver+fis�fI _ j
tt p I Complies. i Coni vents/Assumptions
&Recg,lls I
Value Value —1- ---- - - - --
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies I
[FO4]1 insulation R-value.Where interior R_ R '❑Does Not table for values.
insulation is used,verification
may need to occur during ;❑Not Observable
Insulation Inspection. Not i❑Not Applicable
required in warm-humid locations ;
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 ';insulation installed per ❑Does Not
manufacturer's instructions.
❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[1706]1 'insulation depth of burial or ❑Does Not ;table for values.
distance from top of wall.
❑Not Observable
_ i❑Not Applicable
303;2.1 A protective covering is installed ❑Complies
[FO11]2to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403:9 Snow-and ice-melting system ❑Complies
[17,O1'2]? controls installed. ❑Does Not
❑Not Observable I
`:❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)__1
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users�udsonz\Documents\REScheck\3Caidin Drive.rck Page 4 of 10
Sectaon Plans Verified Field Verified r
Framing/Rough-In Inspection) Value i 1 Complies? -Comments/Assumptions I
& Req.ID I� ( Value i
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
❑
402.3.6, Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 ;U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
s , :with the NFRC test procedure or
•,taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 !Air barrier and thermal barrier ❑Complies 1
[FR23]1 !installed per manufacturer's ❑Does Not
j instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
_ :limits.
402.4.5 IC-rated recessed lighting fixtures, ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate s2.0 cfm
leakage at 75 Pa. []Not Observable
❑Not Applicable
403.2.1 'Supply and return ducts in attics ❑Complies I
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>=3 inches in diameter and >=
R-6 where < 3 inches.Supply and, ❑Not Observable
return ducts in other portions of ❑Not Applicable
:,the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
'for<3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- .❑Complies
[FR17]2 above 105 QF or chilled fluids ❑Does Not
below 55 QF are insulated to zR-
3 ❑Not Observable
,❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
' ❑Not Observable
❑Not Applicable
403;:5 3 Hot water pipes are insulated to R-_ R- ❑Complies
;❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are �❑Complies '
[FR19]z installed on all outdoor air yf ❑Does Not
intakes and exhausts. ❑Not Observable
` ❑Not Applicable
1 High Impact(Tier 1) 2 'Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3 CaitlinDrive.rck Page 5 of10
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2'' Medium Impact(Tier 2) Low Impact(Tier—Y)--
Project
Tier3)Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\RESchec k\3CaitlinDrive.rck Page 6 of 10
Sectoon ; I _—-- --
# i Insulation inspection Plan Verilue�ied FielValuefie Complies? Comments/assumptions
& Req.ID I _
303.1 All installed insulation is labeled ❑Complies
�[IN13]2 or the installed R-values ❑Does Not
provided.
[]Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the
❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 exterior,the exterior insulation E] Mass ❑ Mass ❑Not Observable
requirement applies (FR10). F] Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per []Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2;; Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users�udsonz\Documents\REScheck\3Caitlin Drive.rck Page 7 of10
Sectttan __ _..._____. _._ �.___� ___-• – __�
# Fina! Inspection Provisions ! Plans Verified Field Verified
P Complies-, � Comments/Assumptions
t�eq.Bt3� J( Value Value
i— _�...--__.— --- ----------------- I
j402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
k 402.2.1, F1 Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel Steel i❑Not Observable
402.2.6
[FI1]1 ❑Not Applicable
— -- -------------
303.1.1.1, :Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft'. ❑Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 ,Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation >_R-value of the ;❑Does Not
adjacent assembly.
❑Not Observable
;❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ; ACH 50 ;❑Complies
[FI17]1 `ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. ;❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 { cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ;❑Does Not
<=3 cfm/100 ft2 without air j ❑Not Observable
handler @ 25 Pa. For rough-in
'tests,verification may need to I ;❑Not Applicable
occur during Framing Inspection. ;
403.3.2 ::Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies
[FI27]1 !determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
'leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
;the manufacturer's air handler I
enclosure if installed at time of 1
;test.Postconstruction test:Total
leakage measured with a !
pressure differential of 0.1 inch ;
;w.g.across the entire system ;
including the manufacturer's air I
handler enclosure.
403.3.2.1 ;Air handler leakage designated ❑Complies
(FI24]1 'by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
_ ❑Not Applicable
403.1.1 Programmable thermostats m❑Complies
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable 1
_ ❑Not Applicable j
403.5.1 Circulating service hot water ❑Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) Z' Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3 CaitlinDrive.rck Page 8 of 10
Sectors i Plans Verified i field Verified'
Final Inspection Provssicsns ? Complies? Cornments/Assumptions
- _
Value Value
& Reci.113
403.6.1 All mechanical ventilation system ❑Complies
[F[25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
_ '❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26].2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature. _
403:5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupanc11
y.Controls Y� N � v'r
automatically turn off the pump
° }} �� i
when water is in circulation loop 4 , 4f x
is at set-point temperature and
no demand for hot water exists. ;
403.5.1.2 Electric heat trace systems [:]CO
mplies
[FI2J]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the `❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[FI30]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated []Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system.Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403:5.4 Drain water heat recovery units ❑Complies
[FI31]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to '
'three or more showers.
404.1 75%of lamps in permanent ~❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps
Does not apply to low-voltage []Not Observable
!lighting. ❑Not Applicable
--777-7777
404.1.1 Fuel gas lighting systems have ❑Complies
[FI23]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3; Low Impact(Tier 3)
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3Caitlin Drive.rck Page 9 of10
Plans Verified E Field Verified T Ym
# j c�i
Final Inspeon Provisions complies? Comments/Assumptlons
& Rs 1Ce 1 value Value
)401.3 'Compliance certificate posted. ❑Complies
[F[712 ❑Does Not
-❑Not Observable
❑Not Applicable — —
?303.3 v' Manufacturer manuals for ❑Complies
I(FI1813 mechanical and water heating ❑Does Not
systems have been provided. ❑Not Observable
EE EINot Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 (Medium Impact(Tier 2) ! 3,`Low Impact(Tier=3)=
Project Title: Collette Construction Custom Home Report date: 11/03/17
Data filename: C:\Users\judsonz\Documents\REScheck\3Caitlin Drive.rck Page 10 of 10
C Energy
I&, A lei'!
I V i
I 'T Effkl �mate
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.27
Door 0.10
Efficiency
Heating System:
Cooling System:
Water Heater:
IN
Name: Date:
Comments
r
Manual S Compliance Report Job: 100917
Entire House � --Date: Nov 16,2017
... ^ � � � W P a
COLLETTE CONSTR
I
100917
QUEENSBURY, NY 12804 NOV IV 2*
Project •
For: COLLETTE, COLLETTE CONSTR
QUEENSBURY, NY 12804
Cooling Equipment
Design Conditions
Outdoor design DB: 85.0°F Sensible gain: 23047 Btuh Entering coil DB: 75.3°F
Outdoor design WB: 71.0°F Latent gain: 5025 Btuh Entering coil WB: 62.6°F
Indoor design DB: 75.0°F Total gain: 28072 Btuh
Indoor RH: 50% Estimated airflow: 1103 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split AC
Manufacturer: York Model: TCHD36S41S3+FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1
Actual airflow: 1100 cfm
Sensible capacity: 0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0°F Heat loss: 92949 Btuh Entering coil DB: 65.5°F
Indoor design DB: 68.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9X100C16MP11
Actual airflow: 1100 cfm
Output capacity: 95000 Btuh 102% of load Temp. rise: 50 OF
Meets are all requirements of ACCA Manual S.
wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 2017-Nov-16 10:32:45Page 1
ACCP+ ....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
Residential — Review Form Form
RIPER 1
,gCCK. for HVAC System • • • • ' 15 Mar 09
ArUn& rgc«•aarsoea1a
QUEENSBURY NY
Header Information
Contractor: COLLETTE CONSTR REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes [:] No
Mechanical license: or MJ1AE Form"(and supporting worksheets): Yes F� No M
OEM performance data(heating,cooling,blower): Yes 0 No EJ
Building plan#: 100917 Manual D Friction Rate Worksheet: Yes No
Duct distribution sketch: Yes No �
Home address(Street or Lot#,Block,Subdivision): , Entire House
HVAC LOAD CALCULATION (IRC M1401.3)
Design Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature: -4 °F Orientation: House Front faces North
Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest
Total heat loss: 92949 Btuh Number of bedrooms: 3
Conditioned floor area: 4563 ft2
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 'F Windows Roof
Grains difference: 27 gr/Ib @�0% RH Eave overhang depth: 0 ft
Sensible heatain:
9 25608 Btuh Internal
drapeds,etc. none Eave
Latent heat gain: 5583 Btuh Depth Window
Total heat gain: 31191 Btuh Number of skylights: 0
EQUIPMENTHVAC • 41
Heating Equipment Data Cooling Equipment Data Blower Data
Equipment type: Gas furnace EVi ment type: SplitAC Heating cfm: 1100
Fumace,Heat pump,Boiler,etc. Air�onditioner,Heat pump,etc. Cooling cfm: 1100
Model: York Model: York Static pressure: 0 in H2O
TM9X100016MP11 TCHD36S41 S3 Fas rated external static pressure for
desn'ign airflow
Heating output capacity:. 95900 Btuh Total cooling capacity: 0 Btuh
Heat pumps-capacity atwmterdesignoudoorconditions Sensible cooling capacity: 0 Btuh
Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1)
Design airflow: 1100 cfm Longest supply duct: 0 ft Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct:
Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft
Available static pressure(ASP): 0 in H2O Friction rate: o in/100ft Branch duct: Sheet metal
Friction Rate=ASP=(TEL x 100)
1 declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building
plan listed above. I understand the claims made on these forms will be subject to review and verification.
Contractor's printed name:
Contractor's signature: Date:
Reserved .. -
*Home qualifies for MJ1AE Form based on Abridged Edition Checklist
-F wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116
Pro ect Summary Job: 100917
7 Date: Nov 16,2017
Entire House By:
COLLETTE CONSTR Plan: 100917
QUEENSBURY,NY 12804
Promect Information
For: COLLETTE, COLLETTE CONSTR
QUEENSBURY, NY 12804
Notes:
Design Information
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db -4 °F Outside db 85 °F
Inside db 68 °F Inside db 75 °F
Design TD 72 °F Design TD 10 °F
Daily range M
Reative humidity 50 %
Moisture difference 27 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 87442 Btuh Structure 21972 Btuh
Ducts 5507 Btuh Ducts 1075 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 92949 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 20742 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 5025 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area (ft') 4563 4563 Equipment latent load 5025 Btuh
Volume ft' ) 41067 41067
Air changes/hour 0.70 0.40 Equipment total load 25767 Btuh
Equiv.AVF (cfm) 479 274 Req. total capacity at 0.70 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade HORIZONTAL DISCHARGE
Model TM9X100C16MP11 Cond TCHD36S41S3
AHRI ref 2008692 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1
AHRI ref 3743636
Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER
Heating input 100000 Btuh Sensible cooling 23100 Btuh
Heating output 95000 Btuh Latent cooling 9900 Btuh
Temperature rise 79 °F Total cooling 33000 Btuh
Actual air flow 1100 cfm Actual air flow 1100 cfm
Air flow factor 0.012 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.82
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
W1'1 htsoft® 2017-Nov-1610:32:45
9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
Right-M Worksheet Job: 100917
Entire House Date: Nov 16,2017
COLLETTE CONSTR Pran: 100917
QUEENSBURY, NY 12804
MANUAL J:7th Ed.
1 Name of room Entire House Room1 Room2 Room3
2 Length of exposed wall 664.0 ft 140.0 ft 140.0 ft 27.0 ft
3 Room dimensions 1.0 x 924.0 ft 1.0 x 934.0 ft 10.0 x 7.0 ft
4 Ceilings Condit.Option 9.0 ftj d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft I heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)
EXPOSURE NO. Htg I Clg (ft2) Htg Clg (ft2) Htg I CIg (ft2) Htg I Clg (ft2) Htg Clg
5 Gross a 12E3 5.4 1.0 5976 **** **** 1260 **** **** 1260 **** **** 243 **** ****
Exposed b 0 0
walls and c 0 0
partitions d 0 0 !!!!!! **** .**> !Illil *.*. *.._ !!!!II >**> ..._ **** ****
6 Windows and a 3A0 39.7 ** 250 9918 **** 50 1984 **** 0 0 **** 15 595 ****
glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 *__*
Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
f 0 *• 0 0 •__ 0 0 *••= 0 0 **_= 0 0 ****
7 Windows and North 19.0 80 **** 1520 15 **** 285 0 **** 0 15 **** 285
glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Cooling E/W 68.0 95 **** 6460 35 **** 2380 0 **** 0 0 **** 0
SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
South 34.0 75 **** 2550 0 **** 0 0 **** 0 0 **** 0
Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
8 Other doors a 10DO 33.1 6.3 91 3014 569 0 0 0 0 0 0 21 696 131
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 5635 30429 5748 1210 6534 1234 1260 6804 1285 207 1118 211
exposed b 0 0 0 0 111111 0 0 !!!!!! 0 0 !!!!!!
!!!!!! 0 0
walls and c 0 0
0 0 !!!!!! p p !!!!!! 0 0 II!!!! 0 0
partitions d 0 0 !!!!!! 0 0 !!!!! 0 0 !!!! 0 0 !!!Ili
0 0
e 0 0 !!!! 0 0 !!!! 0 0 !!!!!! 0 0 !!!III 0 0
f 0 0 !!!!II 0 0 !!!!! 0 0 !!!! 0 0 !!!!! 0 0
10 Ceilings a 16GO 2.4 1.1 1884 4476 2114 0 0 0 70 166 79 70 166 79
b 0 0 0 0 !!!!I 0 0 0 0 !!!!!! 0 0
c 0 0 !!!!!! 0 0 111111 0 0 111111 0 0 111111 0 0
d 0 0 !!!!!! 0 0 !I!!!! 0 0 !!!!n 0 0 !!!!!I 0 0
e 0 0 !!!!!! 0 0 !I!!!! 0 0 !!ii 0 0 !!!!i 0 0
f 0 0 !!n 0 0 !I!!!! p p !!!!!! 0 0 !!I 0 0
11 Floors a 1910 1.7 0 924 1597 0 924 1597 0 0 0 0 0 0 0
(Note:room b 1910 1.7 0 20 35 0 0 0 0 10 17 0 10 17 0
perimeter c 1910 1.7 0 16 28 0 0 0 0 0 0 0 0 0 0
is displ. d 0 0 0 0 !MM 0 0 HIM
for slab e 0 0 !!!!!! 0 0 0 0 !!!!!! 0 0 IIII
0 0
floors) f 0 0 !!!!II 0 0 0 0 IIII!! 0 0 IIIIII
0 0
12 Infiltration a 111 8.8 341 37946 3012 50 5564 442 0 0 0 36 4006 318
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 **** 87442 **** **** 15678 **** **** 6988 **** **** 6598 ****
Less external heating **** 0 **** **** 0 **** _*_= 0 *___ **** 0
Less transfer **** 0 **•* •_** 0 *__* **** 0 •_** ••** 0 *_•_
Heating redistribution **** 0 **** **_= 0 *_*_ **** 0 *•_* _•** 0 =_*_
14 Duct loss 6% 5507 **** 6% 987 **** 6% 440 **** 6% 416 ****
15 Total loss= 13+14 **** 92949 **** **** 16666 **** **** 7428 **** **** 7014 ****
16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 **** **** 21972 **** **** 4341 **** **** 1364 **** **** 1024
Less external cooling **** **** 0 **** **** 0 *__* **** 0 **** ___= 0
Less transfer **** **** 0 **** **** 0 **** ***• 0 *••* **** 0
Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0
18 Duct gain 5% **** 1075 5% **** 212 5% **** 67 5% **** 50
19 Total RSH gain=(1 7+18)*P LF 1.00 **** 23047 1.00 **** 4553 1.00 **** 1430 1.00 **** 1074
20 Air required(cfm) 1100 1100 197 217 88 68 83 51
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
4C Pwrightsoft 2017-Nov-16 10:32:451
Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
Right-J®Worksheet Job: 100917
Entire House Date: Nov 16,2017
COLLETTE CONSTR P(an: 100917
QUEENSBURY, NY 12804
MANUAL J.7th Ed.
1 Name of room Room4 Room5 Room6 Room7
2 Length of exposed wall 20.0 ft 3.0 ft 90.0 ft 0 ft
3 Room dimensions 12.0 x 8.0 ft 12.0 x 3.0 ft 1.0 x 732.0 ft 3.0 x 9.0 ft
4 Ceilings Condit.Option 9.0 fti heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)
EXPOSURE NO. Htg I Clg (ft') Htg CIg (ft2) Htg I Clg (ft2) Htg Clg I(ft2) Htg I CIg
5 Gross a 12E3 5.4 1.0 180 **** ***` 27 **** ***` 810 **** `*** 0
Exposed b 0 0
walls and c 0 0
partitions d 0 0
e 0 0
f 0 0 1111!! **** **„ !!i i *.** ..,, MM *"* **** HIM
6 Windows and a 3A0 39.7 ** 15 595 "" 0 0 *"* 60 2380 **** 0 0 ****
glass doors b 0 ** 0 0 *"` 0 0 ***` 0 0 `*`* 0 0 ****
Heating c 0 " 0 0 **** 0 0 ***` 0 0 **** 0 0 ****
d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
e 0 ** 0 0 **** 0 0 **** 0 0 *"* 0 0 `***
f 0 ** o o "`* 0 0 ***` 0 0 •**• 0 0 "•*
7 Windows and North 19.0 0 **** 0 0 **** 0 15 **** 285 0 **** 0
glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Cooling E/W 68.0 0 **** 0 0 "** 0 30 **** 2040 0 **** 0
SE/SW 0 0 **** 0 0 "*` 0 0 **** 0 0 **** 0
South 34.0 15 `*`* 510 0 "" 0 15 **** 510 0 **" 0
Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **" 0
8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 70 2318 438 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 165 891 168 27 146 28 680 3672 694 0 0 0
exposed b 0 0 1111!! 0 0 !!III! 0 0 1111!! 0 0 1111!!
walls and c 0 0 1111!! 0 0
Q 0 111111 � 0 111111 0 0 111111 0 0
partitions d 0 0 1111!! 0 0 0 0 {!!!!i 0 0 iiiiii
0 0
e 0 0 1111!! 0 0 III 0 0 !!!!!i 0 0 1111!! 0 0
f 0 0 1111! 0 0 n 0 0 !!!!n 0 0 !!!!n 0 0
10 Ceilings a 16GO 2.4 1.1 0 0 0 0 0 0 0 0 0 0 0 0
b 0 0 1111!! 0 0 !!!!!! 0 0 1111!! 0 0 !!1111 0 0
c 0 0 1111!! 0 0 1111!! 0 0 1111!! 0 0 1111! 0 0
d 0 0 1111!! 0 0 1111!! 0 0 1111!! 0 0 !!i 0 0
e 0 0 1111!! 0 0 !!! 0 0 1111!! 0 0 0 0
f 0 0 !!!!n o 0 In 0 0 !!i! p 0 n 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
(Note: room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
perimeter c 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
is displ. d 0 0 MM 0 0 1111!! 0 0 !!!111 0 0 1111!!
0 0
for slab e 0 0 !11111 0 0 0 0 1111!! 0 0 1111!!
0 0
floors) f 0 0 !!!!!! 0 0 Ilii 0 0 0 0 Mill
0 0
12 Infiltration a7 111 8.8 15 1669 132 0 0 0 130 14466 1148 0 0 0
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 **** 3155 **** **** 146 **** *`** 22837 **** **** 0 "**
Less external heating **** 0 **** "" 0 **** **** 0 ***` **** 0 ****
Less transfer **" 0 **** •"` 0 '•`* •*** 0 •••• *••* 0
Heating redistribution *"* 0 *"` *"` 0 **** ***` 0 `*`* **** 0 ****
14 Duct loss 6% 199 **** 6% 9 **** 6% 1438 ***` 6% 0
15 Total loss= 13+14 `*`* 3354 **** `*** 155 **** `*** 24275 **** **** 0 ****
16 Int.gains: People @ 300 0 **`* 0 0 **** 0 0 `*** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 **** **** 811 **** **** 28 **** **** 5115 **** **** 0
Less external cooling ***` **** 0 `*** **** 0 `*** **** 0 *`** **** 0
Less transfer **** "** 0 ••" •••* 0 •*•* *•*• 0 **** __*• 0
Cooling redistribution "** ***' 0 *`** •••• 0 •*•* **** 0 **** ••** 0
18 Duct gain 5% **** 40 5% **" 1 5% *`** 250 5% **** 0
19 Total RSH gain=(1 7+18)*P LF 1.00 **** 850 1.00 **" 29 1.00 **** 5365 1.00 "`* 0
20 Air required(cfm) 40 41 2 1 287 256 0 0
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
AC P. - wrightsaft 2017-Nov-16 10:32:45
Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2
....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
Right-J®Worksheet Job: 100917
Entire House Date: Nov 16,2017
COLLETTE CONSTR Ra"n: 100917
QUEENSBURY,NY 12804
MANUAL J:7th Ed.
1 Name of room Room8 Room9 Room10 Room11
2 Length of exposed wall 122.0 ft 26.0 ft 10.0 ft 19.0 ft
3 Room dimensions 1.0 x 872.0 ft 1.0 x 154.0 ft 10.0 x 5.0 ft 1.0 x 74.0 ft
4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ftj heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)
EXPOSURE NO. Htg I CIg (ft2) Htg I CIg (ft2) Htg I CIg (ft2) Htg CIg (ft2) Htg I CIg
5 Gross a 12E3 5.4 1.0 1098 **** "** 234 **** **** 90 **** **** 171 **** ****
Exposed b 0 0 111111 **** `*** 111111 **** **** 111111 **** **** 111111
walls and c 0 0 !!!!!! **" **'* 11111 **" **** 111111
partitions d 0 0 111111 *"' **** 111111 ***` **** Mill "`• *"' 111111 "`* `***
e 0 0
f 0 0 111111 **** **" 1!!111
6 Windows and a 3A0 39.7 ** 0 0 **** 15 595 **** 10 397 **`* 10 397 ***`
glass doors to 0 ** 0 0 **** 0 0 **** 0 0 **" 0 0 ***`
Heating c 0 `* 0 0 **** 0 0 **** 0 0 *"` 0 0 ***`
d 0 `* 0 0 **** 0 0 **** 0 0 **** 0 0 ****
e 0 ** 0 0 "** 0 0 **** 0 0 **** 0 0 ****
f 0 ** 0 0 "`* 0 0 `*** 0 0 **** 0 0 ****
7 Windows and North 19.0 0 **** 0 15 **** 285 10 **** 190 10 **** 190
glass doors NE/NW 0 0 **** 0 0 "`* 0 0 **** 0 0 **** 0
Cooling E/W 68.0 0 **** 0 0 "`* 0 0 **** 0 0 **" 0
SE/SW 0 0 **** 0 0 **** 0 0 ***` 0 0 *"` 0
South 34.0 0 **" 0 0 **** 0 0 `*** 0 0 *"` 0
Horz 0 0 **** 0 0 **`* 0 0 `*** 0 0 **`* 0
8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0
to 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 1098 5929 1120 219 1183 223 80 432 82 161 869 164
exposed b 0 0 Mill 0 0 111111 0 0 111111 0 0 111111
walls and c 0 0 !!!!!! 0 0 111!!! 0 0
partitions d 0 0 11!1! 0 0 111!! 0 0 !!!!!! 0 0
pa 0 0 111111 0 0 111111 0 0 111111 0 0
e 0 0 !!!!!! 0 0 111111 0 0 11!1 0 0 !!!! 0 0
f 0 0 !111!1 0 0 1111 0 0 111 0 0 0 0
10 Ceilings a 16GO 2.4 1.1 872 2072 978 154 366 173 50 119 56 74 176 83
b 0 0 111111 0 0 11111 0 0 111!!! 0 0 111111 0 0
c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
e 0 0 111111 0 0 1!1!11 0 0 111!!1 0 0 11111! 0 0
f 0 0 111111 0 0 1!1111 0 0 1111!1 0 0 111 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
(Note: room to 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
perimeter c 1910 1.7 0 8 14 0 0 0 0 0 0 0 0 0 0
is displ. d 0 0 111111 0 0 111111 0 0 111!1! 0 0 !!!!!!
0 0
for slab e 0 0 !!!!!! 0 0 111 0 0 !!!
0 0 111111 0 0
floors) f 0 0 0 0 1!1111 0 0 0 0 !!!!11
0 0
12 Infiltration a 111 8.8 0 0 0 15 1669 132 10 1113 88 10 1113 88
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 **** 8015 **** **** 3813 **** **** 2060 2555
Less external heating **** 0 **** **** 0 ••*• ___= 0 **** -__* 0 ``**
Less transfer **** 0 •*** **•* 0 **** **** 0 •*** •*_= 0 •••_
Heating redistribution - 0 ***` **** 0 **** **** 0 =_** **** 0 ****
14 Duct loss 6% 505 *`*` 6% 240 **** 6% 130 **** 6% 161 ****
15 Total loss= 13+14 **** 8520 **" `*** 4053 **** "" 2190 **** **** 2716 ****
16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 "** 0 0 "" 0
Appl. @ 1200 0 •*** 0 0 =*** 0 0 *** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 **`* **** 2098 **** "" 814 **** **`* 416 ***` **** 526
Less external cooling *`** **** 0 **** **** 0 **** *_** 0 *___ **** 0
Less transfer ••** **** 0 **** ___= 0 **** •••= 0 =_*` __** 0
Cooling redistribution **`* "'* 0 **** **•• 0 **** **** 0 ***_ **** 0
18 Duct gain 5% **** 103 5% **** 40 5% **** 20 5% "** 26
19 Total RSH gain=(17+18)*P LF 1.00 **" 2201 1.00 **** 853 1.00 "" 436 1.00 **** 551
20 Air required(cfm) 101 105 48 41 26 21 32 26
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
AC P. wrightsoft 2017-Nov-16 10:32
3
Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3
....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
Right-J®Worksheet Job: 100917
Entire House Date: Nov 16,2017
COLLETTE CONSTR Pran: 100917
QUEENSBURY,NY 12804
MANUAL J:7th Ed.
1 Name of room Room12 Room13 Room14 Room15
2 Length of exposed wall 31.0 ft 12.0 ft 0 ft 0 ft
3 Room dimensions 1.0 x 252.0 ft 1.0 x 76.0 ft 4.0 x 9.0 ft 1.0 x 56.0 ft
4 Ceilings Condit. Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ftl heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)
EXPOSURE NO. Htg I Clg (ft') Htg I Clg (ft') Htg I Clg (ft') Htg Clg (ft') Htg I Clg
5 Gross a 12E3 5.4 1.0 279 **** **"` 108 **** *`*` 0 **** *"" 0 **** ****
Exposed b 0 0 !!!!!! «««« *..< 11111 **** ***` !!1111 «__« .... 111111
walls and c 0 0 111111 *«** ***` 111111 ***` ***` 111111 *««« •_•* 11111 **** *"'
partitions d 0 0
e 0 0 111111 *`*` ***` 1!!111 *"« "'* 111111 **** **** !!111!
f 0 0 111111 '*** **** 111111 «««« *_*• 11!!11 **" `*** 111111
6 Windows and a 3A0 39.7 ** 30 1190 **** 15 595 **** 0 0 **** 0 0 ****
glass doors b 0 ** 0 0 `*`* 0 0 **** 0 0 **** 0 0 ****
Heating c 0 ** 0 0 ***` 0 0 **** 0 0 **** 0 0 ****
d 0 `* 0 0 ***` 0 0 *"* 0 0 **** 0 0 ****
e 0 ** 0 0 **** 0 0 ""* 0 0 **** 0 0 ****
f 0 *" 0 0 ***` 0 0 **** 0 0 **** 0 0 ****
7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Cooling E/W 68.0 15 **** 1020 0 **** 0 0 **** 0 0 **** 0
SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 *"* 0
South 34.0 15 **** 510 15 **** 510 0 **`* 0 0 "" 0
Horz 0 0 **** 0 0 *"` 0 0 "** 0 0 **** 0
8 Other doors a 10DO 33.1 6.30 0 0 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 249 1345 254 93 502 95 0 0 0 0 0 0
exposed b 0 0 1111!! 0 0 !!!!ii 0 0 111111 0 0 11111
0 0
walls and c 0 0 !!!!!! 0 0 !!!!!! 0 0 111111
partitions d 0 0 !!!!!! 0 0 111111 0 0 !!!!!! 0 0
0 0 111111 0 0 111111 0 0
e 0 0 11111 0 0 1111 0 0 111111 0 0 11111 0 0
f 0 0 111111 0 0 1111 0 0 0 0 111111 0 0
10 Ceilings a 16G0 2.4 1.1 252 599 283 76 181 85 36 86 40 56 133 63
b 0 0 0 0 111111 0 0 111111 0 0 111111 0 0
c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
d 0 0 111111 0 0 111111 0 0 111111 0 0 HIM 0 0
e 0 0 111111 0 0 !!!!!! 0 0 111111 0 0 11!!11 0 0
f 0 0 !!!!11 0 0 111111 0 0 111111 0 0 111!1 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
(Note:room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
perimeter c 1910 1.7 0 0 0 0 8 14 0 0 0 0 0 0 0
is displ. d 0 0 111111 0 0 111111 0 0 11111 0 0 11
0 0
for slab e 0 0 !!!!! 0 0 !111 0 0 111111 0 0 111111
0 0
floors) f 0 0 111111 0 0 0 0 111111 0 0 11111
0 0
12 Infiltration a 111 8.8 30 3338 265 15 1669 132 0 0 0 0 0 0
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 **** 6472 **** **** 2961 **** **** 86 **"" **** 133 ****
Less external heating **** 0 .... ««** 0 *,** «««« 0 .... .*.. 0 ««««
Less transfer «.«« 0 .... .... 0 «*.. *,*, 0 **** „*` 0 •***
Heating redistribution **** 0 "" ***` 0 "" **** 0 "" **** 0 ****
14 Duct loss 6% 408 "" 6% 186 ... 6% 5 *`** 6% 8 **..
15 Total loss= 13+14 *`** 6879 «««« *"` 3147 ««** **** 91 **** **** 141 ***`
16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 **** **** 2332 **** **** 823 **** **** 40 "`* **** 63
Less external cooling «««« *<* 0 .... •••* 0 •"•• •••• p **"• .««« 0
Less transfer «.«« **«* 0 "••• •••• 0 •••• •••• p >"** .««« 0
Cooling redistribution `*** **** 0 **** **** 0 **** **** 0 **** **** 0
18 Duct gain 5% **** 114 5% **** 40 5% **** 2 5% **** 3
19 Total RSH gain=(17+18)*PLF 1.00 **** 2446 1.00 **** 863 1.00 **** 42 1.00 **** 66
20 Air required(cfm) 81 117 37 41 1 2 2 3
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
wri htsoft" 2017-Nov-1610:32:45
�.�A 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4
...langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=M,17 House Front faces: N
Right-M Worksheet Job: 100917
Entire House Date: Nov 16,2017
COLLETTE CONSTR Pfan: 100917
QUEENSBURY, NY 12804
MANUAL J:7th Ed.
1 Name of room Room16
2 Length of exposed wall 24.0 ft
3 Room dimensions 1.0 x 174.0 ft
4 Ceilings Condit.Option 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Area Area
EXPOSURE NO. Htg I Clg (ft') Htg Clg Htg Cig Htg Clg Htg Gig
5 Gross a 12E3 5.4 1.0 216 **** **** **** **** **** **** **** ****
Exposed b 0 0
walls and c 0 0 **** ***• **** •*** **** ***• **** •*•*
partitions d 0 0 l l l l **** **** **** •*•* **•* •*•* **** .***
e 0 0
f 0 0
6 Windows and a 3A0 39.7 ** 30 1190 **** **** **** ****
glass doors b 0 ** 0 0 **** **** **** ****
Heating c 0 ** 0 0 **** **** **** ****
d 0 ** 0 0
e 0 ** 0 0
f 0 ** 0 0 **** **** **** ****
7 Windows and North 19.0 0 **** 0 **** **** ****
glass doors NE/NW 0 0 **** 0 **** **** ****
Cooling E/W 68.0 15 **** 1020 **** **** ****
SE/SW 0 0 **** 0 **** **** ****
South 34.0 15 **** 510 **** **** ****
Horz 0 0 **** 0 **** **** ****
8 Other doors a 10DO 33.1 6.3 0 0 0
b 0 0 0 0 0
C 0 0 0 0 0
9 Net a 12E3 5.4 1.0 186 1004 190
exposed b 0 0 !!!!!! 0 0
walls and c 0 0 !!!!!! 0 0
partitions d 0 0 !!!!!! 0 0
e 0 0 !!!!!! 0 0
f 0 0 Mill 0 0
10 Ceilings a 16GO 2.4 1.1 174 413 195
b 0 0 !!!!II 0 0
c 0 0 !!!!!! 0 0
d 0 0 !!!!!! 0
0
0
e 0 0 !!!!!! 0
f 0 0 Ill!!! 0 0
11 Floors a 1910 1.7 0 0 0 0
(Note: room b 1910 1.7 0 0 0 0
perimeter c 1910 1.7 0 0 0 0
is displ. d 0 0 !!!!!! 0 0
for slab e 0 0 !!!!li 0 0
floors) f 0 0 !!!!!! 0 0
12 Infiltration a 111 8.8 30 3338 265
Ventilation 0 0
13 Subtotal loss=6+8..+11+12 **** 5946 **** **** **** **** **** **** ****
Less external heating **** p **** **•* **** ***• ***• **** ****
Less transfer **** 0 **** **** •**• **** **** **** _*_*
Heating redistribution **** 0 **** **** **** **** **** **** ****
14 Duct loss 6% 375 **** **** **** ****
15 Total loss=13+14 **** 6321 **** **** **** **** **** **** ****
16 Int.gains: People @ 300 0 **** 0 **** **** ****
Appl. @ 1200 0 **** 0 **** **** ****
17 Subtot RSH gain=7+8..+12+16 **** **** 2180 **** **** **** **** **** ****
Less external cooling **** **** o **** **** **** **** **** ****
Less transfer **** **** p **** **** **** **** **** ****
Cooling redistribution **** **** 0 **** **** **** **** **** ****
18 Duct gain 5% **** 107 **** **** ****
19 Total RSH gain=(1 7+18)*P LF 1.00 **** 2287 20 Air required(cfm) 75 109
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
.4C Awrightsoft 2017-Nov-16 10: e 5
Right-Suite®Universal 2017 17.0.16 RSU25116 Page 5
....langeworthy\Documents\York\COLLETTE CONSTR.rup Calc=MJ7 House Front faces: N
y .
EXHAUST SYSTEMS
TABLE M1507.3.3(1)
CONTINUOUS WHOLE-HOUSE MECHANICAL VENTIATION SYSTE
LATION OF BEDROOMS AIRFLOW RATE REQUIREMENTS
6_7 >7
DWELLING UNIT 2-3 4—5
FLOOR AREA 0—f Airflow in CFM
(square feet) 60 75 90
30 45 90 105
<1,500 75
60
1,501-31000 45 90 105 120
60 75 135
3,001-4,500 105 120
75 90 135 150
*i 4,501-6,000 105 120
6,001-7,500 90 135 150 165
"} >7,500
105 120
For SI: 1 square foot=0.0929 mZ,1 cubic foot per minute=0.0004719 m'/s.
�{
TABLE M1507.3.3(2)
INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa'
0 66% 75%
RUN-TIME PERCgEGMENT EACH 4-HOUR 25% 330 50/° 1 3
.' 4 3 2 1.5
Factora
between
b.
those given,the factors are permitted to be determined by interpolation
a. For ventilation system run time values b .
b. Extrapolation beyond the table is prohibited.
TABLE M1507.4
ONE-AND TWO-FAMILY DWELLINGS
ll MINIMUM REQUIRED LOCAL EXHAUST RATES I
M1507.4 Local exhaust rates. Local exhaust systems sha
be designed to have the capacity to exhaust the minimum air AREA TO BE EXHAUST RATES
flow rate determined in accordance with Table M1507.4. EXHAUSTED
Kitchens 100 cfm intermittent or 25 cfm ca
Bathrooms-Toilet Mechanical exhaust capacity of 5
1. ' !
Rooms intermittent or 20 cfm continuous
For SI: 1 cubic foot per minute=0.0004719 mals.
't
1i r
Y`
4
�:.
2015 INTERNATtONA.
ITO
�ivu
.2 S
Hi AO[Jd
1,Ij N AIIVN S�h 3AVH I
Nil 1 8 d
301.17-3-50 RC-000696-2017
Kelaco, LLC
3 Caitlin Drive
SFD w/FP 1814 s.f., Garage 524 s.f.
tI
S 0
30 0 'a ONicnine rf(p-r
,k8n8SN33no do NMOL
P-
0 LM CO -3 CA L
u
Pplck
do -
1 i ell
L
C4, o Op,
C)
P(ol
PO
CAP
JLT Building Services, LLC Ceqle-.2 >r1
700 Indian Road
Fort Plain, NY 13339
518-925-7718
iltbuildingservices@gmail.com
Blower Door Test Results Report j
Test Date: 0 /3
Client Name: [ (5, -\.;S r
Client Address:
Test Site Address: 3 CAI I Li cbe ,
Test Data
Area Tested [cuft]:
Infiltration Rate Results[CFM@50pa]: /f /1(J7 �'v)
ACH50#as tested at 50 Pascal: m 8 3 '1 v'4
*2015 Code N1102.4.1.2 requires<_3ach
Based on our test results your building meets does not meet
Air Infiltration in accordance with 2015 IECC Residential Code Provisions section R402.4.1.2
I certify the above information as performed in accordance with IECC 2015,ANSI&ASTM protocols,and BPI standards using up to
date calibrated Retrotec equipment models#5101 and#DM32 as required.
Thank You for choosing JLT Building Services LLC.
Jim Telfer
BPI ID#5058106
Signed
VISION Engineering CIVIL,• STRUCTURAL• MUNICIPAL
• e
11/30/17 1DECEONVIE
Building and Codes Department _ MAY 2�1 '
Town of Queensbury
742 Bay Road TOWN OF QUEENSBURY
Queensbury, NY 12804 BUILDING&CODES
RE: Collette Construction
�2C - l0 9 lc •
3 Caitlin Drive- Lot 3 Onsite Sewage System
VISION Engineering, LLC previously designed the Pointe West Subdivision which included the
individual household onsite wastewater disposal system (septic system) for the above location. This
letter shall serve as certification that, upon information obtained from inspections and/or the Contractor,
portions of work designed by our office appear to have been installed in general conformance with
approved plans and specifications.
Thank you and please do not hesitate to contact me if you have any questions or require additional
information.
Sincerely,
. Daniel W. Ryan, P.E.
VISION Engineering, LLC
Daniel W.Ryan P.E.
2018.05.06 09:22:57-04'00'
II MI 206 Glen Street•Suite 56•Glens Falls,NY•12801 •P:518-792-9264
www.visionengineeringllc.com