Loading...
RC-000718-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000718-2017 Date Issued: Thursday, March 29, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000718-2017 has been completed. Tax Map Number: 295.15-2-7 Location: 74 JOHN CLENDON RD Owner: FOOTHILLS BUILDERS,LLC Applicant: FOOTHILLS BUILDERS,LLC This structure may be occupied as a: SFD w/in-law apt.2278 s.f. Cross Ref. Area Variance approval with 25 year condition placed up issuance By Order of Town Board of Certificate of Occupancy;In-Law Apartment expires year 2042 TOWN OF QUEENSBURY Z-AV-68-2017 Issuance of this Certificate of Occupancy DOES NOT relieve the 4 property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000718-2017 Tax Map No: 295.15 T Permission is hereby granted to: FOOTHILLS BUILDERS,LLC For property located at: 74 JOHN CLENDON RD K In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: FOOTHILLS BUILDERS,LLC Single Family-New $250,000.00 Owner Address: 9 Mountainside DR Total Value $250,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency FOOTHILLS BUILDERS,LLC 9 Mountainside DR Queensbury,NY 12804 Plans&Specifications SFD w/in-law apt.2278 s.f. Cross Ref.Area Variance approval with 25 year condition placed up issuance of Certificate of Occupancy;In-Law Apartment expires year 2042 Z-AV-68-2017 $455.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,November 22,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eens jNedn y, ovember 22,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: / 1-7 Permit No. R L—UV 71 Tax Map ID Permit Fee Zone n Historic? _Yes � No Ree Fee Subdivision Name 10 N ''j C( N Da N fLD e -LVt. m..� Site Plan_#. Project Location y �y J0 N N TOWN BD.RESOLUTION 86-2013: $850 recreation fee for 1ellip"piti-6sir a I lexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufacttir lik o u ar homes, u no iIT homes. This is in addition to the permit fee(s). Primary Owner(s) Foothills Builders FEDI'DING& CODES Address 9 Mountainside Drive,Queensbury,NY 12804 Phone/Email (518) 796-3520/(518) 791-1933 / FoothillsBuildersNY@gmail.com Applicant Foothills Builders Address 9 Mountainside Drive, Queensbury,NY 12804 Phone/Email (518) 796-3520/(518) 791-1933 / FoothillsBuildersNY@gmail.com Contractor Foothills Builders Address 9 Mountainside Drive, Queensbury,NY 12804 Phone/Email (518) 796-3520/(518) 791-1933 / FoothillsBuildersNY@gmail.com Contact Person for Building&Codes Compliance: `06 LEU C-1 Phon � l , 33 S"I `716-35 20 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2"d floor sf Total sf Height Single Family Two-Family x L 2_ 2,6 Multi-Family (I 0 (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition S►D f N i A l Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances& Chimneys Are there structures not shown on plot plan? Are there easements on the property? p Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? Yes _ v No c. Will the grade be changed as a result of construction Yes _No d. Public water or Private well (circle one) ublic Private e. Sewer or Private Septic System(circle one) ewer rivate, Value of all work to be performed (labor or materials) $ 2,SC, 00 o DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 7O S P f l DATE: (1 SIGNATURE: DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only i Received DATE: l � � Tax Map 1D TAx MAP ID: S • I L --I L Permit No. t,. tr+- ZONE: Permit Fee (518)796-3650/ APPLICANT Foothills Builders PHONE/E-MAIL 1 (518)791-1933 ADDRESS 9 Mountainside Drive Queensbury,NY 12804 FoothillsBuildersNY@gmail.com INSTALLER/ PHONE/E-MAIL BUILDER Foothills Builders Same as above OWNER Foothills Builders ADDRESS T9 Mountainside Drive Queensbury,NY 12804 CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Joe Leuci PHONE/E-MAIL (518)796/3520/ (518)791-1933 / FoothillsBuildersNY@gmail.com RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes No 1981-1991 Spa or Hot Tub installed Yes CN No 1992-Present p 1 Y PARCEL INFORMATION Topography �_Flat rolling Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is,ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: --3U S E P 0 C u L-1 DATE: SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury, NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: I I I Applicant Name: Foothills Builders Telephone No.: (-5-1 t) 1' 1` 11 33 1,3 Address to be Inspected 1 I �Jt !,'i ( C f-N 9 0 Iz D Return Address: 9 Mountainside Drive Queensbury,NY 12804 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 INSPECTION WORKSHEET (SEP-001614-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000718-2017Case Module:Permit Inspection Date:03/07/2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Septic Job Address:74 JOHN CLENDON RDParcel Number:295.15-2-7 Queensbury, NY 12804 Contact TypeCompany NameName Granted Permission\[FOOTHILLS BUILDERS, LLC\], Primary Owner\[FOOTHILLS BUILDERS, LLC\], Applicant\[FOOTHILLS BUILDERS, LLC\], Contractor\[FOOTHILLS BUILDERS, LLC\], Checklist ItemPassedComments Building Inspector NotesNO3/7/18 Septic System Not Approved-Not completed. Received call from engineer Tom Center to reinspect tomorrow morning. Scheduled for 9:00 - 11:00 am. Public Sewer Sign-OffNO Soil Type: SandNO Soil Type: LoamNO Soil Type: ClayNO Type of Water: Municipal / Well WaterNO Waterline separation distanceNO Well separation distanceNO Well Casing Lengt: 50ft +/-NO Absorbtion Fields: Total LengthNO Septic system field above flood plainNO Septic tanks & pump station anchored in flood zoneNO Length of Each TrenchNO Depth of TrenchesNO Size of StoneNO Seepage Pits: NumberNO Size:NO Stone Size:NO Building to TankNO Tank to Distribution BoxNO Distribution box to Field / PitNO Opening Sealed:NO End CapNO InletOutlet Pipes & BafflesNO Manholes 12 or less below gradeNO \[Provide extension collar if Yes\]NO Locations / SeparationsNO Foundation to TankNO Mar 07, 2018Page (13) INSPECTION WORKSHEET (SEP-001614-2018) Checklist ItemPassedComments Foundation to AbsorptionNO Separation of PitsNO Conforms as per Plot PlanNO Engineer Report and As-BuiltNO ETU Maintenance Contract providedNO Location of system on propertyNO System Use StatusNO O'Brien, John (Inspector) Mar 07, 2018Page (14) 1280 A. Manual S Compliance Report Job: p p Nov Date: Nov 08,2017 Entire House By: SLL Plan: 1280 FOOTHILL BUILDERS QUEENSBURY,NY 12804 Project Information s For: JOE LEUCI, FOOTHILL BUILDERS "� `rts( QUEENSBURY, NY 12804 TOWN O � y ........... _ �r ....,... Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 28393 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 6476 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 34869 Btuh Indoor RH: 50% Estimated airflow: 1359 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCGD42S41S4+CX420B(6,9)35+T"(8,L)V"C16 Actual airflow: 1260 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 111269 Btuh Entering coil DB: 65.4°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X120D20MP11 Actual airflow: 1260 cfm Output capacity: 114000 Btuh 102% of load Temp. rise: 50 °F 295.15-1-6 RC-000718-2017 Foothills Builders 74 John Clendon Rd., Lot 9 Meets are all requirements ofACCA Manual S. SFD wlin-law apt. 2278 S.f. 2017-Nov-08 10:59:48 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 /4C>- ...ott.langeworthy\Documents\York\BERUBE LOT 9.rup Calc=MJ7 House faces: N Form Residential ' — _ • ACCK. • ASystemDesign (Loads, Equipment, Ducts) 15 Mar 09 ArW-da«:,s cvtaxxs dare, QUEENSBURY NY Header Information Contractor: FOOTHILL BUILDERS REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes E] No ❑ Mechanical license: or MJ1AE Form`(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes E] No ❑ Building plan#: 1280 Manual D Friction Rate Worksheet: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): , Entire House Duct distribution sketch: Yes E] No ❑ HVAC LOAD CALCULATION Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: House faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 111269 Btuh Number of bedrooms: 4 Conditioned floor area: 5881 ftz Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib @50% RH Eave overhang depth: 0 ft Sensible heat gain: 31548 Btuh Internal shade: none � Blinds,drapes,etc. Eave Latent heat gain: 7196 Btuh P Depth Window Total heat gain: 38744 Btuh Number of skylights: 0 EQUIPMENTHVAC • 40 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type: Split AC Heating cfm: 1260 umace,Heatpump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 1260 Model: York Model: York Static pressure: 0 in H2O TM9X120D20MP11 TCGD42S41 S4 Fan's rated external static pressure for Heating output capacity: 114900 Btuh Total cooling capacity: 0 Btuh design airflow Heat pumps-capacty atwinterdesignoudoorconditions Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh DISTRIBUTIONHVAC DUCT •1 Design airflow: 1260 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: g in/100ft Branch duct: Sheet metal Friction Rate=ASP+tTELx 10 ) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved •. "Home qualifies for MJ1AE Form based on Abridged Edition Checklist wrightSOW Right-Suite®Universal 2017 17.0.16 RSU25116 Project Summa Job: 1280 Date: Nov 08,2017 Entire House By: SILL FOOTHILL BUILDERS Plan: 1280 QUEENSBURY,NY 12804 Promect Information For: JOE LEUCI, FOOTHILL BUILDERS QUEENSBURY, NY 12804 Notes: Design Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 104676 Btuh Structure 27069 Btuh Ducts 6593 Btuh Ducts 1324 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 111269 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 25554 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6476 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heatin Cooling (none) Area (ft2 588 5889 Equipment latent load 6476 Btuh Volume (f?) 52929 52929 Air changes/hour 0.70 0.40 Equipment total load 32030 Btuh Equiv.AVF (cfm) 618 353 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade ADP Model TM9X120D20MP11 Cond TCGD42S41S4 AHRI ref 2008696 Coil CX420B(6,9)35+T*(8,L)V*C16 AHRI ref 6492466 Efficiency 95.5AFUE Efficiency 11.0 EER, 14 SEER Heating input 120000 Btuh Sensible cooling 26460 Btuh Heating output 114000 Btuh Latent cooling 11340 Btuh Temperature rise 82 °F Total cooling 37800 Btuh Actual air flow 1260 cfm Actual air flow 1260 cfm Air flow factor 0.011 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. Wrl htsoftw 2017-Nov-0810:59:48 �.. 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACC. ...ott.langeworthy\Documents\York\BERUBE LOT 9.rup Calc=MJ7 House faces: N Right-J®Worksheet Job: 1280 *► Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Flan: 92& QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Entire House Room1 Roorn2 Room3 exposed wall 2 Length of exp732.0 ft 164.0 ft 164.0 ft 45.0 ft 3 Room dimensions 1.0 x 1411 ft 1.0 x 1411 ft 1.0 x 376.0 ft 4 Ceilings Condit.Option 9.0 ftj d 9.0 ft heat/cool 9.0 fti heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg I Clg (ft2) Htg Clg I (ft2) Htg Clg (ft2) Htg CIg I(ft') Htg Clg 5 Gross a 12E3 5.4 1.0 6588 '*** `*** 1476 **** ***' 1476 ***` **** 405 Exposed b 0 0 !![111 .*** _<.. !!I!!! ***. .... 1111!! .*** `*.* MH walls and c 0 0 !!!III "*` "*' 1111!! _*** _'** 111111 =_** _*** ••__ **__ partitions d 0 0 e 0 0 f 0 0 111111 :•*• ___* 111111 **_* *__* 111111 **__ **** 111!!1 **** __*_ 6 Windows and a 3D0 26.0 ** 420 10917 **** 80 2079 '*** 0 0 ***` 70 1819 glass doors b 0 *` 0 0 **** 0 0 **** 0 0 ***` 0 0 Heating c 0 *' 0 0 ***` 0 0 *"* 0 0 **** 0 0 **** d 0 *' 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 ***' 0 0 **** 0 0 `*** 0 0 `*** f 0 ** 0 0 **** 0 0 '*** 0 0 "** 0 0 **** 7 Windows and North 17.0 170 "" 2890 20 **** 340 0 *"* 0 70 **** 1190 glass doors NE/NW 0 0 **'* 0 0 ***` 0 0 *"` 0 0 **** 0 Cooling E/W 62.0 90 **** 5580 60 **** 3720 0 "" 0 0 **** 0 SE/SW 0 0 *"` 0 0 **** 0 0 **" 0 0 **`* 0 South 30.0 160 "" 4800 0 **** 0 0 ***` 0 0 **" 0 Ho¢ 0 0 "" 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10DO 33.1 6.3 84 2782 526 0 0 0 0 0 0 21 696 131 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 6084 32854 6206 1396 7538 1424 1476 7970 1506 314 1696 320 exposed b 0 0 !!!!1 0 0 !!! 0 0 1111!! 0 0 111111 0 0 walls and c 0 0 1111!! 0 0 !!! 0 0 1111!! 0 0 1111!! 0 0 partitions d 0 0 1111!! 0 0 u 0 0 1111!! p p !!!!11 0 0 e 0 0 1111!! 0 0 0 0 1111!! 0 0 !!!!ii 0 0 f 0 0 pull 0 0 n 0 0 !!!!!1 0 0 !!11 0 0 10 Ceilings a 16GO 2.4 1.1 2840 6748 3186 0 0 0 581 1380 652 6 14 7 b 0 0 0 0 !!!!!I 0 0 1111!! 0 0 1!!!!! 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 0 0 1111! 0 0 1111!! 0 0 1111 0 0 e 0 0 VIII! 0 0 1111! 0 0 !!1 0 0 0 0 If 0 0 !!!n 0 0 !!! 0 0 !!!!11 0 0 !!1! 0 0 11 Floors a 1910 1.7 0 1411 2438 0 1411 2438 0 0 0 0 0 0 0 (Note: room b 1910 1.7 0 18 31 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 !!!!!! 0 0 1111!! 0 0 0 0 !!!!!! 0 0 is displ. d 0 0 !11111 0 0 !!!!n 0 Q 111111 Q 0 111111 0 0 for slab e 0 0 1111 0 0 0 0 111111 0 0 0 0 floors) f 0 0 0 0 !!!!n 0 0 0 0 0 0 12 Infiltration a 97.0 7.7 504 48906 3881 80 7763 616 0 0 0 91 8830 701 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 104676 `*** "*` 19819 "" **** 9351 `*** **'* 13055 Less externa!heating *"' 0 `*`* "_* 0 =*** ___* 0 *___ **** 0 =__* Less transfer "•' 0 =_** __** 0 '*** ___= 0 *"- •__= 0 **•* Heating redistribution *`*' 0 **** '*** 0 **** `__= 0 *"' `*** 0 **" 14 Duct loss 6% 6593 ***` 6% 1248 **** 6% 589 ***` 6% 822 **** 15 Total loss= 13+14 **** 111269 "" *'*' 21067 "" **** 9940 **** "" 13877 16 Int.gains: People @ 300 0 "`* 0 0 "*' 0 0 **** 0 0 `**` 0 Appl. @ 1200 0 `•`* 0 0 •*'= 0 0 •••= 0 0 **•* 0 17 Subtot RSH gain=7+8..+12+16 "*` `*" 27069 **** **" 6100 *`** **** 2157 **** "** 2349 Less externa!cooling *"` **** 0 **** ***` 0 *"* **** 0 **** "'* 0 Less transfer **" **`• 0 '__* *•** 0 *___ __** 0 =__• __•= 0 Cooling redistribution **" ***' 0 *'__ **** 0 *_*_ __*= 0 **** **_* 0 18 Duct gain 5% **** 1324 5% **** 298 5% "" 106 5% **** 115 19 Tota!RSH gain=(1 7+18)*P LF 1.00 **** 28393 1.00 .*** 6398 1.00 **** 2263 1.00 **** 2464 20 Air required(cfm) 1260 1260 239 284 113 100 157 109 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. .4CA wrightsoft 2017-Nov-08 10:59:48 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ..ott.langeworthy\Documents\York\BERUBE LOT 9.rup Calc=MJ7 House faces: N Right-M Worksheet Job: 1280 Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Plan: 12 0 QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Room4 Room5 Room6 Room? 2 Length of exposed wall 24.0 ft 27.0 ft 5.0 ft 17.0 ft 3 Room dimensions 1.0 x 297.0 ft 13.0 x 14.0 ft 5.0 x 11.0 ft 6.0 x 11.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/coo! 9.0 ft heat/coo! 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 216 **** **** 243 """* **** 45 **** **** 153 **** **** Exposed b 0 0 walls and c 0 0 !! .*>* **._ HIM **** **** **_" *"_• ...... partitions d 0 0 !!!!!I ***" "."" 11!! **** **** HIM _..* _•_* iii """" .*** e 0 0 f 0 0 **** **** II!!II 6 Windows and a 3D0 26.0 ** 30 780 *"* 40 1040 **** 10 260 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 ***" 0 0 **"" Heating c 0 "" 0 0 **** 0 0 **** 0 0 **** 0 0 **"" d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 17.0 15 **** 255 15 **** 255 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 62.0 0 **** 0 25 ***" 1550 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 *•** 0 0 •*** 0 South 30.0 15 *"** 450 0 **** 0 10 *""* 300 0 **** 0 Horz 0 01 - 0 0 **** 0 0 **** 0 0 ***= 0 8 Other doors a 10DO 33.1 6.3 42 1391 263 0 0 0 0 00 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 144 778 147 203 1096 207 35 189 36 153 826 156 exposed b 0 0 111111 0 0 !!!!!! 0 0 I 1111! 0 0 1111!! 0 0 walls and c 0 0 partitions d 0 0 0 0 !!! 0 0 0 0 1111!! 0 0 pa 0 0 111111 0 0 111111 0 0 !11111 e 0 0 1111 0 0 0 0 f 0 0 !!!!II 0 0 1111!! 0 p 1111!! 0 0 0 0 !! 0 0 MM 0 0 n 0 0 10 Ceilings a 16GO 2.4 1.1 272 646 305 182 432 204 55 131 62 66 157 74 b 0 0 0 0 1111!! 0 0 !!!!!! !! 0 0 0 0 C 0 0 0 0 III!!! 0 0 1111!! p 0 1111!! 0 0 d 0 0 0 0 ! 0 0 11 !!!!!I 0 0 1111!! 0 0 e 0 0 0 0 1111!! 0 0 1111!! 0 0 1111!! 0 0 f 0 0 0 0 !!III 0 0 1111!! 0 0 !!Illi 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note: room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 0 0 !III 0 0 1111! is displ. d 0 0 0 0 0 0 ! 0 0 for slab e 0 0 !I 0 0 1111!! 0 0 0 0 0 0 !!!!I! p 0 1111!! 0 0 !!!!u 0 0 floors) fl 1 0 0 !!!II 0 0 0 0 0 0 !!!!II 0 0 12 Infiltration a 97.0 7.7 72 6987 554 40 3881 308 10 970 77 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 10581 **** "*** 6450 ***" **"* 1550 **** **** 983 **** Less externa!heating **** 0 "__ __** 0 **** _*_* 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** *"** 0 **** **** 0 **** **** 0 "*** 14 Duct loss 6% 666 **** 6% 406 **"* 6% 98 **** 6% 62 **** 15 Tota!loss= 13+14 **** 11248 **** **** 6856 **** **** 1648 **** *""" 1045 **** 16 Int.gains: People @ 300 0 **** 0 0 "*** 0 0 **** 0 0 **** 0 App!. @ 1200 0 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1974 ***" **** 2524 **** "*** 474 **** **** 230 Less external cooling "*** *"** 0 ***_ **** 0 =___ **** 0 **** **** 0 Less transfer **** **** 0 ***_ **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 97 5% **** 123 5% **** 23 5% **** 11 19 Tota!RSH gain=(1 7+18)*P LF 1.00 **** 2071 1.00 **** 2648 1.00 "*** 498 1.00 **** 241 20 Air required(cfm) 1 1 1271 921 1 781 1181 1 191 221 1121 11 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. .4-- � wrightsoft 2017-Nov-08 10:59:48 Right-Suite®Universal 2017 17.0.16 RSU25116 ..ott.langeworthy\Documents\York\BER USE LOT 9.rup Calc=M.17 House faces: N Page 2 Right-J®Worksheet Job: 1280 Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Pran: iso QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Room8 Room9 Room 10 Room11 2 Length of exposed wall 3.0 ft 24.0 ft 19.0 ft 0 ft 3 Room dimensions 13.0 x 3.0 ft 12.0 x 12.0 ft 17.0 x 12.0 ft 6.0 x 3.0 ft 4 Ceilings Condit. Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg I Clg (ftz) Htg Clg 1 (ftz) Htg Clg (ft') Htg Clg (ft') Htg Clg 5 Gross a 12E3 5.4 1.0 27 **** **** 216 **** **** 171 **** **** 0 Exposed b 0 0 !!!!ii **** *__* !!!!ii **__ **• ilii .**_ ***_ ____ ._** walls and c 0 0 .*.* *_** **._ .._* !!!!!! *... **** iiiiii *•__ *___ partitions d 0 0 .*** **_• !i *.*_ *._• !!i i **.. ..** iiiiii *.** **** e 0 0 !!!ii =... ***. !!!!!i **** **** 6 Windows and a 3D0 26.0 ** 5 130 **** 30 780 **** 30 780 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 =*** Heating c 0 * 0 0 •__= 0 0 *•*= 0 0 **_* 0 0 d 0 ** 0 0 ***= 0 0 *•** 0 0 •**= 0 0 •_*_ e 0 ** 0 0 **** 0 0 **** 0 0 ***= 0 0 *_*_ f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 17.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 62.0 5 **** 310 0 **** 0 0 **** 0 0 *_** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 30.0 0 **** 0 30 **** 900 30 **** 900 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 21 696 131 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 01 0 01 0 0 9 Net a 12E3 5.4 1.0 22 119 22 186 1004 190 120 648 122 0 0 0 exposed b 0 0 !! ! 0 0 III!!! 0 0 i 0 0 !!i 0 0 walls and c 0 0 !!!!!! 0 0 ! 0 0 partitions d 0 0 !!!!!! 0 0 !!!!I 0 0 !!!!!! 0 0 0 0 !!!!!! 0 0 II!I!! 0 0 e 0 0 0 0 !!!II! 0 0 !!!! f 0 0 n !!!!u 0 0 0 0 0 0 0 0 !!!!n 0 0 !!!!n 0 0 10 Ceilings a 16GO 2.4 1.1 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 !!!!! c 0 0 0 0 !!!!!! 0 0 !!!!!! !ii 0 0 i 0 0 d 0 0 0 0 1!1111 Q Q 111111 Q Q 111111 0 0 e 0 0 i 0 0 0 0 !!!i !!!!!! 0 0 !!!!!! 0 0 f 0 0 0 0 !!n 0 0 0 0 !!!!ii 01 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note: room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 !!!!!! 0 0 !!!!!! 0 p is displ. d 0 0 !!!!!i 0 0 !!!n 0 0 !!!!!! 0 0 for slab e 0 0 0 0 !!!!!! 0 0 !!! 0 0 0 0 !!I!! 0 p !!!!!! p 0 0 0 floors) f 0 0 0 0 0 0 !!!!!! 12 Infiltration a 97.0 7.7 5 485 39 30 2911 231 51 4949 393 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 ***= 734 **** **** 4695 **** *** 7072 **** **** 0 - Less extemal heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer =_** 0 =_** •**= 0 =*•* •••• 0 *••* **_• 0 **** Heating redistribution **** 0 =_*• **** 0 =*•• **** 0 *___ *__* 0 **** 14 Duct loss 6% 46 **** 6% 296 **** 6% 445 **** 6% 0 **** 15 Tota!loss= 13+14 **** 780 **** **** 4991 **** **** 7518 **** **** 0 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 App!. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8,.+12+16 **** **** 371 **** **** 1321 **** **** 1547 **** **** 0 Less externa!cooling ** _*** 0 **** **** 0 =_** ___* 0 **** •*** 0 Less transfer ***_ *__= 0 =*** _*** 0 =_*_ **_= p **** _*•• 0 Cooling redistribution **** **_* 0 =••• ___= 0 *_** **•* 0 **** **_= 0 18 Duct gain 5% **** 18 5% **** 65 5% **** 76 5% **** 0 19 Tota!RSH gain=(1 7+18)*P LF 1.00 **** 389 1.00 **** 1385 1.00 **** 1622 1.00 **** 0 20 Air required(cfm) 9 17 1 57 61 85 72 0 0 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. .4CP. wrightsoft 2017-Nov-08 10:59:48 Right-Suite®Universal 2017 17.0.16 RSU25116 ..ott.langeworthy\DocumentslYork\BERUBE LOT 9.rup Calc=MJ7 House faces: N Page 3 Right-J®Worksheet Job: 1280 Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Pan: 1280 QUEENSBURY, NY 12804 MANUAL J: 7th Ed. 1 Name of room Room13 Room14 Room16 Room17 2 Length of exposed wall 120.0 ft 27.0 ft 25.0 ft 7.0 ft 3 Room dimensions 1.0 x 839.0 ft 1.0 x 186.0 ft 1.0 x 112.0 ft 7.0 x 7.0 ft 4 Ceilings Condit. Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg I Clg (ft') Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 1080 .*** *"*' 243 "" **" 225 **" **** 63 **** **** Exposed b 0 0 1111 **`" **** 111!!1 **" **** 111!!! "'** **`* 111!11 walls and c 0 0 !!!!!! '**` `*** 111111 partitions d 0 0 111!!! "" "`" !1111 **** """ "*" **** 11111 ***• *•*• e 0 0 •••* „*" !11111 *""" ••*> 1!!111 "" •*•• 111�� *•*• **** f 0 0 11111 "`* "" 111111 **'* **** 1 "'* *""* ••** **** 6 Windows and a 3D0 26.0 " 0 0 *""" 30 780 **"" 20 520 '*** 0 0 **** glass doors b 0 ** 0 0 **" 0 0 ""** 0 0 **** 0 0 **** Heating c 0 ** 0 0 ***' 0 0 "*** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 "*** e 0 *` 0 0 ***' 0 0 ***` 0 0 **** 0 0 *""* f I 1 01 0 0 "" 0 0 **" 0 0 **** 0 0 ***' 7 Windows and North 17.0 0 ***" 0 30 "*"" 510 20 "" 340 0 **"" 0 glass doors NE/NW 0 0 ***" 0 0 **** 0 0 ***' 0 0 *"* 0 Cooling E/W 62.0 0 "** 0 0 "" 0 0 **** 0 0 "*** 0 SE/SW 0 0 *"' 0 0 *"* 0 0 **'* 0 0 **** 0 South 30.0 0 *'** 0 0 **** 0 0 *"` 0 0 `*** 0 Horz 0 0 **** 0 0 **** 0 0 "" 0 0 '*** 0 8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 1080 5832 1102 213 1150 217 205 1107 209 63 340 64 exposed b 0 0 111111 0 0 11!111 0 0 111 walls and c 0 0 11!!!! 0 0 0 0 0 0 111111 p p 111111 p p 111111 0 0 partitions d 0 0 !!!!! 0 0 !11 0 0 111111 e 0 0 111 0 0 11 0 0 111 0 0 111111 f 0 0 1 0 0 0 0 0 0 111111 0 0 111111 0 0 10 Ceilings a 16GO 2.4 1.1 839 1993 941 186 442 209 112 266 126 49 116 55 b 0 0 HIM p p 111111 p p 111111 p p 111111 C 0 0 IIIIII 0 p 111111 0 0 !!!!!! 0 0 11111! 0 0 111111 0 0 d 0 0 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 !11111 0 0 ! 0 0 !!!! 0 0 11111! 0 0 f 0 0 111111 0 0 1!11! 0 0 11111 0 0 !!!!!! 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note: room b 1910 1.7 0 9 16 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 IIIIII 0 0 111111 0 0 1111 0 0 111 is displ. d 0 0 0 0 11111 0 0 0 0 111111 p p 111111 0 0 for slab e 0 0 0 0 !!!!!! 0 0 1!111! 0 0 !!!!11 0 0 floors) f 0 0 0 0 111111 0 0 1!I I I c 0 0 111111 0 0 12 Infiltration a 97.0 7.7 0 0 0 30 2911 231 20 1941 154 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 7841 '*** ***` 5283 "** ***" 3834 "" **** 457 **** Less external heating **** 0 *** **** p **** ***= p ,.__ *•_= p **** Less transfer <`•* 0 **<• *••• 0 *•• •*** 0 **** **** 0 **** Heating redistribution - 0 ***` *"*' 0 *"" **"* 0 **** **** 0 *'*" 14 Duct loss 6% 494 ***' 6% 333 ""** 6% 241 ""** 6% 29 ''*' 15 Total loss= 13+14 *"' 8335 '*** **** 5616 *"** "" 4075 "** **'* 485 *"" 16 Int.gains: People @ 300 0 **'* 0 0 - 0 0 **** 0 0 *'** 0 Appl. @ 1200 0 *"** 0 0 - 0 0 *"** 0 0 - 0 17 Subtot RSH gain=7+8..+12+16 **" **** 2043 **** **** 1167 **** **** 829 **** **** 119 Less external cooling *"` **** 0 **** **** 0 ***` "" 0 "** **** 0 Less transfer `*`" "*" 0 ""` '"** 0 "*" '"" 0 •••• ***" 0 Cooling redistribution **" "** 0 •"•' **** 0 **** **** p •-_• _*•* p 18 Duct gain 5% **** 100 5% """* 57 5% '*" 41 5% '**" 6 19 Total RSH gain=(17+18)*P LF 1.00 **** 2143 1.00 '*** 1224 1.00 869 1.00 ***' 125 20 Air required(cfm) 94 95 64 54 46 391 1 5 6 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. i4C P. 4+1- wrightsoft' 2017-Nov-08 10:59:48ag4 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 ..ott.langeworthy\Documents\York\BER UBE LOT 9.rup Calc=MJ7 House faces: N Right-JO Worksheet Job: 1280 Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Plan: 1280 QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Room18 Room19 Room20 Room21 2 Length of exposed wall 0 ft 25.0 ft 9.0 ft 4.0 ft 3 Room dimensions 7.0 x 9.0 ft 1.0 x 146.0 ft 1.0 x 95.0 ft 14.0 x 4.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg I Clg (ft2) Htg Clg (ft2) Htg I Clg (ft2) Htg Clg (ft2) Htg I Clg 5 Gross a 12E3 5.4 1.0 0 "" '"" 225 ***` **** 81 ***_ **** 36 ***• _*** Exposed b 0 0 walls and c 0 0 !!!!!! *_.. x.*. !!!!!! **"_ *.*. !!!!!! .*__ *".. HIM .." *... partitions d 0 0 6 Windows and a 3D0 26.0 *' 0 0 **** 30 780 ***` 15 390 **** 0 0 glass doors b 0 ** 0 0 '**' 0 0 '*** 0 0 **** 0 0 **** Heating c 0 *` 0 0 "" 0 0 '*** 0 0 "`* 0 0 **** d 0 *` 0 0 "*' 0 0 "** 0 0 **** 0 0 **** e 0 ** 0 0 "" 0 0 "** 0 0 **** 0 0 f 0 "" 0 0 "" 0 0 "'* 0 0 "'** 0 0 7 Windows and North 17.0 0 "'* 0 0 '*'* 0 0 *"' 0 0 **** 0 glass doors NE/NW 0 0 **" 0 0 ""' 0 0 ***' 0 0 "*** 0 Cooling E/W 62.0 0 ***` 0 0 "" 0 0 ***' 0 0 **** 0 SE/SW 0 0 **** 0 0 "" 0 0 **** 0 0 "" 0 South 30.0 0 **** 0 30 *"' 900 15 **** 450 0 ""' 0 Horz 0 0 **** 0 0 **" 0 0 **** 0 0 **'* 0 8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 0 0 0 195 1053 199 66 356 67 36 194 37 exposed b 0 0 !!!111 0 0 !!!!!! 0 0 !!!!!! walls and c 0 0 !!!!!! 0 0 !!!!!! 0 0 !!!! 0 0 11!1!! 0 0 partitions d 0 0 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 !!!!!! 0 0 !!! 0 0 !!!!!! 0 0 !!!!!! 0 0 f 0 0 !!!!ii 0 0 !!t!!! 0 0 !!!!n 0 0 !!!!n 0 0 10 Ceilings a 16GO 2.4 1.1 63 150 71 146 347 164 95 226 107 56 133 63 b 0 0 !!!!!! 0 0 0 0 0 0 !!!!!! 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 !!!!!! 0 0 !!!!!i 0 0 !!!!!! 0 0 !!!!!! 0 0 e 0 0 !!!!!i 0 0 !!!!!! 0 0 !!!!!i 0 0 !!!!i 0 0 f 0 0 !!!!!i 0 0 !!!!i 0 0 !!!!n 0 0 !!!i 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 0 0 0 2 3 0 7 12 0 0 0 0 perimeter c 0 0 !!! 0 0 !! 0 0 !!!!!! 0 0 !!!!!! 0 0 is displ. d 0 0 !!!!! 0 0 !! 0 0 !!!!! 0 0 !!!!!! 0 0 for slab e 0 0 !!!!! 0 0 0 0 !!!! 0 0 !!!!!! 0 0 floors) f 0 0 0 0 0 0 0 0 !!!!ii 0 0 12 Infiltration a 97.0 7.7 0 0 0 30 2911 231 15 1456 116 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 150 - **** 5094 - **** 2440 """ **** 327 "*** Less externa!heating **** 0 - **'* 0 "*' *"' 0 **** **"' 0 **** Less transfer **** 0 "'* "" 0 **** "" 0 **** **** 0 **** Heating redistribution '*** 0 "'* *"* 0 **** `*** 0 **** **** 0 "*** 14 Duct loss 6% 9 "** 6% 321 **** 6% 154 **** 6% 21 15 Tota!loss= 13+14 `*** 159 **** "" 5415 **** "" 2593 **** **** 348 `*** 16 Int.gains: People @ 300 0 **** 0 0 "" 0 0 **** 0 0 *'"' 0 App!. @ 1200 0 **** 0 0 "** 0 0 **** 0 0 *"" 0 17 Subtot RSH gain=7+8..+12+16 ***' **** 71 **** *"* 1494 **** **** 739 **** ***' 100 Less external cooling **** **** 0 *"' **** 0 '*" **** 0 "" "*' 0 Less transfer ***• *•"' 0 *•** •••* 0 =*__ **** 0 =•" _`<' 0 Cooling redistribution **'* **'* 0 **** **** 0 **** **** 0 *•*` ***• 0 18 Duct gain 5% '*" 3 5% **** 73 5% "** 36 5% "" 5 19 Total RSH gain=(1 7+18)*P LF 1.00 **** 74 1.00 **** 1567 1.00 "" 776 1.00 **** 104 20 Air required(cfm) 2 3 61 701 1 29 341 1 4 5 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsaft'9 2017-Nov-08 10:59:48ag5 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 5 ...ott.langeworthy\Documents\York\BER UBE LOT 9.rup Calc=MJ7 House faces: N Right-J®Worksheet Job: 1280 Entire House Date: Nov 08,2017 FOOTHILL BUILDERS Pfan: 1280 QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Room22 2 Length of exposed wall 23.0 ft 3 Room dimensions 12.0 x 11.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Area Area EXPOSURE NO. Htg Clg (ftz) Htg Clg Htg Clg Htg Clg Htg Clg 5 Gross a 12E3 5.4 1.0 207 Exposed b 0 0 !!!!!i walls and c 0 0 1!!!!! partitions d 0 0 11!!!! 6 Windows and a 3D0 26.0 30 780 glass doors b 0 ** 0 0 Heating c 0 ** 0 0 d 0 ** 0 0 e 0 " 0 0 f 0 ** 0 0 l 1 7 Windows and North 17.0 0 **** 0 glass doors NE/NW 0 0 **** 0 Cooling E/W 62.0 0 ***` 0 SE/SW 0 0 *`*` 0 South 30.0 30 "" 900 Hoe 0 0 "" 0 8 Other doors a 10DO 33.1 6.3 0 0 0 b 0 0 0 0 0 c 0 0 0 0 0 9 Net a 12E3 5.4 1.0 177 956 181 exposed b 0 0 1111!! 0 0 walls and c 0 0 1111!! 0 0 partitions d 0 0 1111!! 0 0 e 0 0 1111!! 0 0 f 0 0 !ii 0 0 10 Ceilings a 16GO 2.4 1.1 132 314 148 b 0 0 !!!!!1 0 0 c 0 0 11!!11 0 0 d 0 0 11!1!1 0 0 e 0 0 !!!!!! 0 0 f 0 0 !!!!ii 0 0 11 Floors a 1910 1.7 0 0 0 0 (Note: room b 1910 1.7 0 0 0 0 perimeter c 0 0 !!!!!! 0 0 is displ. d 0 0 !!!111 0 0 for slab e 0 0 !!!!!! 0 0 floors) f 0 0 !!1111 0 0 12 Infiltration a 97.0 7.7 30 2911 231 Ventilation 0 0 13 Subtotal loss=6+8,.+11+12 ''" 4960 "" Less externa!heating **** 0 **** **** **** Less transfer ••** 0 **** '*** **** •••* **** `*** **** Heating redistribution **** 0 14 Duct loss 6% 312 **** **** **** **** 15 Tota!loss= 13+14 **`* 5273 **** **** **** **** **** **** **** 16 Int.gains: People @ 300 0 **" 0 **** App!. @ 1200 0 **** 0 **** 17 Subtot RSH gain=7+8..+12+16 **" **** 1460 **** **** **** **** **** **** Less external cooling `*** **** 0 Less transfer **** "" 0 *•" •••* **** "*` ***• ***• Cooling redistribution **** *`** 0 18 Duct gain 5% **** 71 19 Tota!RSH gain=(17+18)*PLF 1.00 **** 1531 20 Air required(cfm) 60 68 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrlghtsOft 2017-Nov-08 10:59,486 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 6 Ott .langeworthy\Documents\York\BERUBE LOT 9.rup Calc=MJ7 House faces: N REScheck Software Version 4. .4 Compliance Certificate o 00 N � 00 N r- N Project Foothills Builders o 0 O J Energy Code: 2015 IECC (,) Location: Glens Falls, New York U -0 Construction Type: Single-family --� (��" -" (' "`p°" ��ju J Y I E C E V 'C O CL Project Type: New Construction 'D _ 0 � Conditioned Floor Area: 2,278 ft2 Glazing Area 16% O 0 CU Climate Zone: 6 (7635 HDD) NOV 16 2017 , N (� i Permit Date: Permit Number: TOWN OF QUEENSBURY :E -C Construction Site: Owner/Agehf: Designer/Contractor: N `O ti � John Clendon Dr VISION Engineering, LLC Lot 9 206 Glen Street Queensbury, NY 12804 Suite 56 Glens Falls, NY 12801 trade-off�6rnplliance: Passes using UA Compliance: 0.0%Better Than Code Maximum UA: 334 Your UA: 334 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling 1: Raised or Energy Truss 1,450 38.0 0.0 0.025 36 Wall 1:Wood Frame, 16" o.c. 1,494 21.0 0.0 0.057 68 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 202 0.290 59 Door 1: Solid 34 0.200 7 Door 2: Solid 18 0.200 4 Door 3: Glass 20 0.240 5 Door 4: Glass 20 0.240 5 Wall 2: Wood Frame, 16" o.c. 965 21.0 0.0 0.057 48 Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 119 0.290 35 Basement Wall 1: Solid Concrete or Masonry 1,295 0.0 15.0 0.046 58 Wall height: 7.8' Depth below grade: 7.0' Insulation depth: 7.8' Window 3: Vinyl/Fiberglass Frame:Double Pane 12 0.340 4 Window 4: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Floor 1: All-Wood Joist/TYuss:Over Outside Air 10 30.0 0.0 0.033 0 Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 1 of 10 Compliance State ment- The proposed building design described h e is onsistent with the building plans, specifications, and other calculations subwith the permit application.The proposed wilding has been designed to meet the 2015 I CC requirements in REScheck Versioand to comply with the mandatory requ' emen{s liste the RES eck Inspection Chec lis V .� Name-Title Sign a ate K W LU y � 2 d � X10,0 07906Q� R�ESS1�c�j Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 2 of 10 REScheck Software Version 4.6.4 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Sectiss Plans Verifier! j Field Verified ? # re Inspection/Plays Review plies. � Comments/Assumptions bc`tteq.fD Value Value 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, 'Construction drawings and "❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for (PR3)1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC .Commercial Provisions. _. ...._........__ 302.1, ;Heating and cooling equipment is Heating. Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods []Not Observable i Btu/hr Btu/hr approved by the code official. ❑Not Applicable 1 Additional Comments/Assumptions: I 1 ,High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 3 of 10 section Plans Verified Field Verified # Foundation inspection Value Value Complies? Comments/Assumptions &Req.l 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4)1 insulation R-value.Where interiorR_ R_ ❑Does Not table for values. F insulation is used, verification may need to occur during ❑Not Observable j Insulation Inspection. Not ❑Not Applicable i required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall �,14- t ,y ❑Complies [FO511 insulation installed per ❑Does Not manufacturer's instructions. 0� ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall �_. ft ft ❑Complies ;See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not :table for values. distance from top of wall. ❑Not Observable f' []Not Applicable 303.2.1 A protective covering is installed ❑Complies [FOIl]2 to protect exposed exterior ❑Does Not insulation and extends a '.minimum of 6 in. below grade. ❑Not Observable s� �,�, � ; r t ❑Not Applicable ; 403',9 Snow and ice melting system ❑Complies [FO12]2 controls installed. ❑Does Not t' ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Medium Impact(Tier 2) 3.!Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 4 of 10 ` n /R in ctiaCairn�rt��s? � �c�mmentslAssum)atilons »lid t + - �Fio�w lue 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable A01 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance y�� 'x ❑Does Not with the NFRC test procedure ori , taken from the default table. ❑Not Observable '„❑Not Applicable 402.4.1.1 Air barrier and thermal barrier 9 ❑Complies [FR23]1 installed per manufacturer's t°sem y ❑Does Not instructions. ❑Not Observable r ❑Not Applicable M mr......,, -; 402.4.3 Fenestration that is not site built '- ❑Complies [FR20]1 is listed and labeled as meeting []Does Not AAMA/WDMA/CSA 101/i.5.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. ] y` .._..._._ . ..... _._ ..._... ............__ 402:4:6 IC-rated recessed lighting fixtures,,; '' s`. ❑Complies if R16]2 sealed at housing/interior finish z ❑Does Not and labeled to indicate <_2.0 cfm `- leakage at 75 Pa. -]Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Comp lies [FR12]1 insulated >= R-8 where duct is 1 =❑Does Not >= 3 inches in diameter and >_ � s s � :R-6 where < 3 inches.Supply and����f ��� � °.���f ❑Not Observable return ducts in other portions of ,; ❑Not Applicable the building insulated >= R-6 for g ti y diameter>= 3 inches and R-4.2 for< 3 inches in diameter. f t 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not t ❑Not Observable ' ❑Not Applicable 4034 ;HVAC piping conveying fluids R- R- ❑Complies ]F(,1,712 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- °� 3. ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC a� -�, :< . _:=❑Complies [FR24]1 piping. ❑Does Not 0- � z _ ❑Not Observable , e3❑Not Applicable 403,53 Hot water pipes are insulated to R- R- ❑Complies if R1$12 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air s sx "❑Does Not intakes and exhausts. � « y ❑Not Observable ❑Not Applicable 1 ?High Impact Merl) 2' Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 5 of 10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 6 of 10 Section Plans Verified Field Verlfled # insulation Inspection Value Value Complies? Comments/Assumptions 6 Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values -Oboes Not provided. .a y [-]Not Observable y. � ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions andN -JDDoes Not [IN2]1 in substantial contact with the underside of the subfloor, or floor , ❑Not Observable framing cavity insulation is in �"ITH ?.,❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the '< s.e underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. %. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [I1\13]1 exterior,the exterior insulation ; requirement applies (FR10). ❑ Steel E] Steel ❑Not Applicable .....I..................................._.. 303.2 Wall insulation is installed per = ' ❑Complies [IN4)1 manufacturer's instructions. ( ❑Does Not f ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 7 of 10 - Project Title: Foothills Builders Report date: 11/03/17 Section Plans Verified Field Verified # Final Inspection Provisions Value ._—_—Value - Complies? Comments/Assumptions &Req.iD i 403.6.1 All mechanical ventilation system ❑Complies OR [F125]2 fans not part of tested and listed y ❑Does Not HVAC equipment meet efficacy ¢;. and air flow limits. ❑Not Observable i ❑Not Applicable 403:2 Hot water boilers supplying heat <`>,; ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water []Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for ss circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop ; is at set-point temperature and no demand for hot water exists. , 403.5.1.2 Electric heat trace systems ❑Complies IF129]2 comply with IEEE 515.1 or UL �jy ❑Does Not 515. Controls automatically adjust the energy input to the h ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. .� . -.......... _ -_.._...__.__........._........._ ..__.... 403.5.2 Water distribution systems that ' ❑Complies [F130]2 have recirculation pumps that []Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable i water supply pipe have a demand recirculation water �yY) system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 0315.4 Drain water heat recovery units ❑Complies IF13112 tested in accordance with CSA ❑Does Not 1355.1. Potable water-side pressure loss of drain water heat v ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. ' A 404.1 75%of lamps in permanent r °s ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable _ 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 9 of 10 Section ;: . ' Flans Verified F V ~ '- 0 Final Inspection Pr+sarlsions �taplles nmmerit Asswrl eE Fteq.ID Value' V 4013 Compliance certificate posted. >Elcomplies y ❑Does Not � [F17]2y In r ❑Not Observable ENot Applicable 303.3 Manufacturer manuals for h ❑Complies [FI18]3 mechanical and water heating y []Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 11/03/17 Data filename: C:\Users\lrobision\Desktop\1280 rescheck.rck Page 10 of 10 s 2015 I ECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating LI-Factor SHGC Window 0.29 Door 0.20 Cooling'Heating& . . Heating System• Cooling System: Water Heater: Name: Date• Comments