Loading...
RC-0029-2018 TOWN OF QUEENSBURY 742 Bay Road, Queensbury,NY 12804-5904 (518)761-8201 - - - Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0029-2018 Date Issued: Tuesday, June 19, 2018 This is to certify that work requested to be done as shown by Permit Number RC-0029-2018 has been completed. Tax Map Number: 308.12-1-46 Location: 28 WOODEN LN Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: Single Family Dwelling w/gas FP 2304 s.f. By Order of Town Board Garage 440 s.f. TOWN OF QUEENSBURY Laric Development, Lot 21 Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0029-2018 Tax Map No: 308.12-1-46 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 28 WOODEN LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $240,000.00 Owner Address: 1 Marions Way Total Value $240,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications Single Family Dwelling w/gas FP 2304 s.f. Garage 440 s.f. Laric Development,Lot 21 $ 1,841.20 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,February 9, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Qu k7for 9,2018 SIGNED BY: �,Yf the Town of Queensbury. Director of Building&Code Enforcement U111C:v— lJ�ir UBiile `A PRINCIPLE STRUCTURE PERMIT ' APPLICATION Permit Fee:$ C/ 2 Town ofCueensbLL7 *Rec Fee: $ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Invoice#: Project Location: %A000M;3-L LP04W- Tax Map ID #: : vZ- S rr f e� ICU 1-- �1C-� *TOWN BD, RESOLUTION 86-2013: $850 recreation fee f r dwelling uni s: s y,duplexes/two-family, multiple family, apartments, condominiums,townhouses, a arJA*t2r6d4e od I mes, but not mobile homes. This Is In addition to the permit fee(s). TOWN OF QUEENSBURY CONTACT INFORMATION: BUILDING&CODES • Applicant: Name(s): iCIS C_kfz.O.�C� t L�� Mailing Address, C/S/Z: 1 1` 5 1 XY, Cell Phone: S�`� ) '8'Dt`l • �2--11 1 Land Line: �5� ) �"t�• �3b i • Primary Owner(s): Name(s): gam= sue_ Mailing Address, C/S/Z: Cell Phone: Land Line: Email: • Contractor(s): Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: �_) Land Line: Email: Arch itect(s)/Engineer(s): Business Name: 1LE9"n-} � -' �� 1 �° �• Contact Name(s): Mailing Address, C/S/Z: Cell Phone: `1677g• 240Z Land Line: E m a i l: 1Lrv�-ram'C3::>% Contact Person for Building & Code Compliance: Cell Phone: ( ,>``b ) Land Line: ) Email: 'i � �c.�� t-t t d�a._sc,s C,c*A Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial WORK CLASS: X Single-Family Two-Family _Multi-Family(#of ) Townhouse Business Office _Retail _Hotel/Motel IndustriaUWarehouse Garage(#of cars j Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 11 floor: Z Z-1 11 floor: 2nd floor: 055 � 2nd floor: 1 3rd floor: - Total square feet: 40 ift 4t'floor: Total square feet: Z ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 2. Proposed use of the building: 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): 40 Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO Explain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES NO d. What is the water source? UBLI PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? 5��C-- Town of Queensbury Building&Code Enforcement Principle Structure Appbation Revised February 20 DECLARATION: 1. 1 acknowledge that no construction shall commence prior to issuance of a valid b u i I ding permit and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: 112(,11 Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 f..r . FUEL BURNING APPLIANCE & office Use only CHIMNEY APPLICATION Permit n: �, - o0 2�t•2� I Permit Fee:$ Icnstt o�(Zmciisbury Invoice:#: 742 Bay Road, Queensbury, NY 12804 P: 518-761-8256 www.gueensburV.net Project Location: 2 b W007a\-\ 40 Tax Mall ID 4: Room of Install: -P--CW Planned Install Date: **ONE APPLICATION PER APPLIANCE** CONTACT INFORMATION: • Applicant: Name(s): MaC44aAELs Cozo-Y:- �c -+S, u C- Mailing Address, C/S/Z: I MAr-MQt-k'r-- Lj�-`< l+ =-Kk-1 kc-ttst t-E�; W 1741a Cell Phone: '5k4 ) er-i -(6-4►u Land Line: �) Email: J e "104.b- s Ste.cc*A • Primary Owner(s): Name(s): A$�> P4E044E7 Mailing Address, C/S/Z: Cell Phone: _( ) Land Line: _( ) Email: InstallerJBuilder: Business Name: FkZa AJEX-� Contact Name(s): CA=A�rA "-bAA0v=-" Mailing Address, C/S/Z: 1-7b® - Cell Phone: _( 5R> ) SW: a- ekPC=> Land Line: _( ) Email: Contact Person for Building & Code Compliance: IUK,-e L0 '�xfl Cell Phone: _( r--A4a ) 165-1 ,2-A44- Land Line: _( ) Email: Fuel Burning Appliance &Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: v - TYPE OF DEVICE: Stove _Fireplace Insert '14 Fireplace _Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) X Fireplace, factory built** **Manufacturer's name: Hc"AW-N- C.rLC> Model#: SOURCE OF HEAT: Wood Coal Pellet )4 Gas CHIMNEY INFORMATION: Masonry: block brick stone _Flue: tie _steel _size, in inches _Material*: double-wall _triple-wall_insulated (*Manufacturer's name: Model #: ) ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces& chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above::' PRINT NAME: 61°`,L7 /Z !c SIGNATURE: DATE: Fuel Burning Appliance &Chimney Application Revised March 2017 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 '>„°•'fcL„ „h`"' P:518-761-8256 www.gueensburY.net Permit#: n o 2� - 2-01`J Tax Map ID#: Permit Fee: $ ; Invoice#: Project location: �� �'\ -7`��'� �— Septic Variance? Yes No Primary Owner(s)Mailing Address Phone & Email 5,t) .961=19 , Comet --Ae ijk1 e "I AND E3 SCt CC," Installer/Builder -Li,�-s, �� �y � gvc� Mailing Address 154 rl�010=Tt_\ 12e)7-9 Phone & Email "5\1b .-74-7g":'112-1 1 Engineer Mailing Address t(cr-t F- t*4ii_i�V2) �> Phone & Email . 74-5 Contact Person for Building&Code Compliance: rtZ -`�' sG� Phone: RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes No 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes No Installed? (circle one) 1992-Present IJt5V/ PARCEL INFORMATION: Topography Flat Rolling Steep Slope %Slope Soil Nature _ k5and Loam Clay Other Groundwater At what depth? k11_1 Bedrock/Impervious material At what depth? X/'+ Domestic Water Supply --4 Municipal _Well (if well, water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size IZf,,:, gallons(min.size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length ft.; Each Trench ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency; 2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: " � � ��1� DATE: Z6 SIGNATURE: r' DATE: Town of Queensbury Building&Code Enforcement Revised February 2017 Town ©f Queensbury Thomas R. Vasa Ness Highway Superintendent Highway Home (518) 745-0929 Department 742 Bay Road—Queensbury, NY 12801 David Duell Phone: (518) 761-8211 Deputy Highway Superintendent F Home (518) 743-0938 Fax: (518) 745-4466 DRIVEWAY PERMIT 0 0 2-1 - 26 i DATE: �I-Z 3 J 16 APPLICANT NAME: M►C-�-txx s C(Zv,p }kC .s , LXX- TELEPHONE NO.: E->tq�> ." 6311 ADDRESS TO BE INSPECTED: RETURN ADDRESS: 1 N1D� NS WAs-t' W1�1At11Gel1Ll� N.-/ �Z11� Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( } Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15„ ( ) 18„ ( ) 24„ ( ) 36- Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent FEB 0 9 2018 TOWN OF QUEINI ,BURY COMMUNITY DEVEl.O?M�� `5EE EQUIPMENT d DUGT SIZING GALGULATIONS SUBMITTED WITH PERMIT APPLIGATION FOR ADO'L INFORMATION — — ea — — FURNAGE — — —E— fi-3==i — 6"O ROUND METAL DUCT —2FRE5H AIR INTAKE RETURN AIR LENNOX"HEALTHY-AIR" W/WEATHER HOOD PLENUM FRESH AIR MAKE-UP KIT W/MOTORIZED DAMPER (SEE ADJAGENT GALG5) MEGHANIGAL VENTILATION SYSTEM NOTES: MECHANICAL VENTILATION SHALL BE PROVIDED IN GOMPLIANGE WITH IRG R303 8 IRG M1501.3.1. VENTILATION SYSTEM SHALL GON515T OF EXHAUST FAN5(LOCATED®MASTER AND MAIN BATHS) USED IN GONJUNGTION WITH A FRESH-AIR MAKE-UP DAMPER CONNECTED TO THE RETURN-AIR PLENUM OF FURNAGE(SEE ADJAGENT DIAGRAM) VENTILATION REQUIRED: = 600m 6ONTINUOU5(PER TABLE M1501.3.3(I)OR 120cfm AT 50%RUN TIME PER TABLE M1501.3.39(2) VENTILATION PROVIDED: (2)BOcfm FANS(MAIN 8 MASTER BATH)OPERATING®50%RUN TIME (2-HOUR INTERVALS) = IbOcfm>120cfm.PROGRAMMABLE TIMERS SHALL BE PROVIDED AT EACH EXHAUST FAN LOCATION. MAKE-UP AIR DAMPER SHALL OPERATE VIA A PROGRAMMABLE TIMER WHICH GOINGIDES WITH BATH FAN TIMERS(2-HOUR INTERVALS)TO ELIMINATE NEGATIVE PRESSURE WITHIN HOME MECHANICAL VENTILATION - 28 WOODEN LANE TOWN OF Qu&C SB n8 ooden Ln Buw)ING Load Calculations for The Michaels Group a ' t y RmD.14N"AL, HVAC L CSA i i I 308.12-1-46 RC-0029-2018 Prepared By: Michaels Group Homes LLC Nick Abrunza 28 Wooden Lane, Lot 21 Appolo"eating 868 Burdeck St SFD w/gas FP 2304 s.f., Gar. 440 s.f. Schenectady Ny 12306 Monday, January 22,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. i Rhvac Residential&Light Commercial HVAC Loads =. Elite Software Development,Inc. Appolo Heating Inc. 28 Wooden Ln I Schenectady, NY 12306 _ Page 2 - - -- -- LProject Report General Project Information Project Title: 28 Wooden Ln Designed By: The Michaels Group Project Date: Monday, January 22, 2018 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data ------- -------- Reference City: Schenectady, New York Building Orientation: Front door faces Northwest Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 1,290 CFM Per Square ft.: 0.353 Square ft. of Room Area: 3,655 Square ft. Per Ton: 1,396 Volume (ft'): 30,450 Building Loads_ _ Total Heating Required Including Ventilation Air: 62,308 Btuh 62.308 MBH Total Sensible Gain: 27,993 Btuh 89 % Total Latent Gain: 3,434 Btuh 11 % Total Cooling Required Including Ventilation Air: 31,427 Btuh 2.62 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM Rhvac-Residential&Light Commercial HVAC Loads Elite software Development,Inc. Appolo Heating Inc. 28 Wooden Ln Schenectady, NY 12306 _ _ _ _Pa e 3 MiscellaneousRep ort System I Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference. Winter: 1 0.31 800% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 j Duct Sizing Inputs- -- --- -- -- ---- Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data _ — Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 188 CFM 96 CFM Infiltration Actual: 0.370 AC/hr 0.190 AC/hr Above Grade Volume: X 30,450 Cu.ft. X 30,450 Cu.ft. 11,267 Cu.ft./hr 5,785 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 188 CFM 96 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(188 CFM), Construction:Average Summer Infiltration Specified: 0.190 AC/hr(96 CFM), Construction: Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM [-R-hv-aP-Residential&Light Commercial HVAC Loads 1, Elite Software Development,Inc. Appolo Heating Inc. 7 28 Wooden Ln Schenectady,NY 12306 ------- Pane 4 Load Preview Report Mini Mini Sys S Sys. Net Q'i Seni Lai Net Sen Ht Cig Ht ( Ducl I 1 9 c Scope To /To r Area Gairl Gal Gain Loss SiZE --- I CFM gi CFM CFM CFM CF_ Building 2.62 1,396 3,655 27,993 3,434 31,427 62,308 820 1,290 820 1,290 1,290 System 1 2.62 1,396 3,655 27,993 3,434 31,427 62,308 820 1,290 820 1,290 1,290 12x1 Zone 1 3,655 27,993 3,434 31,427 62,308 820 1,290 820 1,290 1,290 12x1 f 1-Basement 1,218 2,213 579 2,792 14,233 187 102 187 102 102 1-6 2-Breakfast 84 1,686 132 1,818 3,746 49 78 49 78 78 1-5 3-Kitchen 138 978 47 1,025 1,805 24 45 24 45 45 1-4 4-Mud Room 42 644 28 672 1,080 14 30 14 30 30 1-4 5-Dining 178 1,855 95 1,950 3,486 46 85 46 86 85 1-5 6-Foyer 112 824 39 863 1,644 22 38 22 38 38 1-A 7-Living 190 1,777 130 1,907 4,136 54 82 54 82 82 1- 8-Powder Room 73 902 31 933 1,217 16 42 16 42 42 1-4 9-Great Room 394 2,685 209 2,894 7,533 99 124 99 124 124 2-5 10-Bedroom 2 191 1,989 416 2,405 3,948 52 92 52 92 92 1-6 11-WIC 1 56 543 25 568 928 12 25 12 25 25 1- 12-Bath 1 61 670 42 712 1,285 17 31 17 31 31 1-A 13-Loft 81 726 0 726 764 10 33 10 33 33 1-4 14-Bedroom 4 169 2,447 409 2,856 3,896 51 113 51 113 113 2-4 15-Open To Foyer 136 1,269 69 1,338 1,635 22 58 22 68 58 1-4 16-Bedroom 3 174 2,456 407 2,863 3,909 51 113 51 113 113 2-4 17-Master Bath 90 1,210 38 1,248 1,777 23 56 23 56 56 I-A 18-Master Bedroom 269 3,117 738 3,855 5,286 70 144 70 144 144 2-5 C:\UsersWcka\Docunnents\E1ite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM ` Rhvac-Residefltial&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 28 Wooden Ln Schenectady,NY 12306 Page 5 Duct Size Preview Room or I Mmimu i Maximu i Rough Desig SPS Duct Duct! Htg CIg Act. Duct Duct Name (Source f Veioci y Veloci� Facto U10 -LosS1 Velocity' Lengt Flow___Flow__-_Flow-]_Size,-_ -- -- - ------J -- - System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 519.3 187 102; 102 1-6 2-Breakfast Built-In 450 750 0.01 0.1 569.7 49 78 78 1-5 3-Kitchen Built-In 450 750 0.01 0.1 516.7 24 45 45 1 4-Mud Room Built-in 450 750 0.01 0.1 340.3 14 30 30 1-4 5-Dining Built-In 450 750 0.01 0.1 627 46 85' 85 1-5 6-Foyer Built-In 450 750 0.01 0.1 435.4 22 38 38 1 7-Living Built-in 450 750 0.01 0.1 600.6 54 82, 82 1-5 8-Ponder Room Built-in 450 750 0.01 0.1 476.4 16 42 42 1-4 9-Great Room Built-In 450 750 0.01 0.1 453.8 99 124 124 2-5 10-Bedroom 2 Built-In 450 750 0.01 0.1 466.8 52 92 92 1 11-WIC 1 Built-In 450 750 0.01 0.1 286.9 12 25 25 1-4 12-Bath 1 Built-In 450 750 0.01 0.1 353.6 17 31' 31 1 13-Loft Built-In 450 750 0,01 0.1 383.1 10 31 33 1 14-Bedroom 4 Built-In 450 750 0.01 0.1 646.1 51 113 113 2-4 15-Open To Foyer Built-In 450 750 0.01 0.1 670.2 22 581 58 1-4 16-Bedroom 3 Built-in 450 750 0.01 0.1 648.5 51 113 113 2-4 17-Master Bath Built-In 450 750 0.01 0.1 638.9 23 56 56 1-4 18-Master Bedroom Built-In 450 750 0.01 0.1 526.7 70 144'i; 144 2- Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 860 820 1,29d 1,290 12x1 Summary System 1 .-- Heating Flow: 820 Cooling Flow: 1290 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM ` Rhvac-Residobtial&Light Commercial HVAC Loads ry. Elite Software Development,Inc. Appolo Heating Inc. 28 Wooden Ln Schenectady,NY 12306 - _____page 6 Total Building Summary Loads -- - Component. Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 320.3 6,852 0 4,684 4,684 Pella Slider: Door-Slider 40.8 845 0 282 282 Fire Rated: Door-Fire Rated 19 368 0 123 123 Front Door TMG: Door-TMG Entry U-Value 0.19 20.4 267 0 89 89 12E-Obm: Wall-Frame, R-19 insulation in 2 x 6 stud 1115.4 7,928 0 964 964 cavity, no board insulation, brick finish, metal studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2214.3 9,929 0 1,770 1,770 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1226.1 2,199 0 1,499 1,499 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1218 2,101 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 2035.9 15,568 0 2,707 2,707 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 265.2 2,192 0 380 380 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl Subtotals for structure: 48,249 0 12,498 12,498 People: 5 1,500 2,000 3,500 Equipment: 0 0 0 Lighting: 3510 11,969 11,969 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 188, Summer CFM: 96 14,059 1,934 1,256 3,190 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 270 270 Total Building Load Totals: 62,308 3,434 27,993 31,427 Check Figures - - -- --- Total Building Supply CFM: 1,290 CFM Per Square ft.: 0.353 Square ft. of Room Area: 3,655 Square ft. Per Ton: 1,396 Volume(ft'): 30,450 Building Loads - Total Heating Required Including Ventilation Air: 62,308 Btuh 62.308 MBH Total Sensible Gain: 27,993 Btuh 89 % Total Latent Gain: 3,434 Btuh 11 % Total Cooling Required Including Ventilation Air: 31,427 Btuh 2.62 Tons (Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM Rhvac Residential Light Commercial HVAC Loads Elite Software Development,Inc. i Appolo Heating Inc. 28 Wooden Ln Schenectady NY 12306 _ _ Page 26 System 1 Room Load Summary 1 Htg Min Run Run Clg Clg Min Act I Room Area Sens Htg Duct Duct Sens Lat Cig Sys 1 No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone I--- 1 --1 Basement 1,218 14,233 187 1-6 519 2,213 579 102 102 2 Breakfast 84 3,746 49 1-5 570 1,686 132 78 78 3 Kitchen 138 1,805 24 1-4 517 978 47 45 45 4 Mud Room 42 1,080 14 1-4 340 644 28 30 30 5 Dining 178 3,486 46 1-5 627 1,855 95 85 85 6 Foyer 112 1,644 22 1-4 435 824 39 38 38 7 Living 190 4,136 54 1-5 601 1,777 130 82 82 8 Powder Room 73 1,217 16 1-4 476 902 31 42 42 9 Great Room 394 7,533 99 2-5 454 2,685 209 124 124 10 Bedroom 2 191 3,948 52 1-6 467 1,989 416 92 92 j 11 WIC 1 56 928 12 1-4 287 543 25 25 25 12 Bath 1 61 1,285 17 1-4 354 670 42 31 31 13 Loft 81 764 10 1-4 383 726 0 33 33 14 Bedroom 4 169 3,896 51 2-4 646 2,447 409 113 113 15 Open To Foyer 136 1,635 22 1-4 670 1,269 69 58 58 16 Bedroom 3 174 3,909 51 2-4 649 2,456 407 113 113 17 Master Bath 90 1,777 23 1-4 639 1,210 38 56 56 _118 Master Bedroom 269 5,286 70 2-5 527 3,117 738 144 144 System 1 total 3,655 62,308 820 27,993 3,434 1,290 1,290 System 1 Main Trunk Size: 12x18 in. Velocity: 860 ft./min Loss per 100 ft.: 0.102 in.wg i Cooling System Summary Cooling Sensible/Latent Sensible Latent Total _ Tons Split Btuh Btuh _ Btuh Net Required: 2.62 89%/11% 27,993 3,434 31,427 Actual: 3.33 75%/25% 30,000 10,000 40,000 _ I LEquipment Data Heatinq System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-* 13ACXN042-230-** Indoor Model C35-49C**+TDR Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 40,000 Btuh Sensible Capacity: n/a 30,000 Btuh Latent Capacity: n/a 10,000 Btuh AHRI Reference No.: n/a 8630634 I i i i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\28 Wooden Ln.rh9 Monday, January 22, 2018, 10:43 AM REScheck Software Version 4.6.2 Complian ' ' e Do JAN 2 6 2018 �`� Ry N Project PC552 - Aster Q' ���N 0 c J TOWN OF QUEENSBUR Energy Code: 2015 IECC BUILDING&CODES � v Location: Warren County, Ne Construction Type: Single-family �� _ _J 0 Project Type: New Construction �'J'� p� 8 � r dj N Conditioned Floor Area: 2,304 ft2 ) � Glazing Area 16% a 0 J (L Climate Zone: 6 (8499 HDD) 0 N Permit Date: 17 January, 2018 H N Permit Number: r y p � M0O3 Construction Site: Owner/Agent: Designer/Contractor: v > C) 28 Wooden Lane Michaels Group Homes, LLC p 00 u- Queensbury, NY 1 Marions Way M c N Mechanicville, NY Compliance:Passes using UA trade-off Compliance: 0.6%Better Than Code Maximum UA: 319 Your UA: 317 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Foundation Wall: Solid Concrete or Masonry 1,117 0.0 19.0 0.039 42 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 2x 6030 Sliding Windows: Vinyl/Fiberglass Frame:Double Pane with Low-E 36 0.300 11 lx Std Basement Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 2 0.300 1 1st Floor Walls: Wood Frame, 24" o .c. 1,323 21.0 0.0 0.056 60 lx Living (AU): Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.300 11 Foyer#1: Solid 21 0.170 4 lx Dining (AU): Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.300 11 Mud #20: Solid 19 0.170 3 2x Breakfast(B):Vinyl/Fiberglass Frame:Double Pane with Low-E 19 0.300 6 Breakfast#7: Glass 40 0.300 12 2x Great Room (E): Vinyl/Fiberglass Frame:Double Pane with Low-E 29 0.300 9 lx Great Room (R): Vinyl/Fiberglass Frame:Double Pane with Low-E 27 0.300 8 2x Great Room (AP): Vinyl/Fiberglass Frame:Double Pane with Low-E 11 0.300 3 lx Powder(AM): Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.300 2 2nd Floor Walls: Wood Frame, 24" o .c. 1,160 21.0 0.0 0.056 57 Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 1 of 10 Gross Area Cavity Cont. Assembly or U-Factor UA= Perimeter lx Bed #3 (G): Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 lx Foyer(BB): Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.300 5 lx Bed #4 (G): Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 lx Bath (AM): Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.300 2 lx Bed #2 (U):Vinyl/Fiberglass Frame:Double Pane with Low-E 17 0.300 5 lx Master Bed (G): Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 lx Master Bath (AM): Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.300 2 Ceiling: Raised or Energy Truss 1,293 38.0 0.0 0.025 32 Plant Shelf: All-Wood Joist/Truss:Over Outside Air 28 30.0 0.0 0.033 1 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has en designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements liste the R check Inspection Checklist. Oce rbz 7 e ,(a�'- j I Z Name-Title Signature .' Date Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section 1i Plans Verified Field Verified # Pre-InspectianlPIan Review Complies? ! Comments/Assumptions & Req.ID I Value Value i 1 103.1, Construction drawings and ❑Complies ;103.2 documentation demonstrate 7-]Does Not I[PR111 energy code compliance for the ❑Not Observable building envelope.Thermal envelope represented on [:]Not Applicable construction documents. - --- - 1103.1, Construction drawings and ❑Complies 1103.2, documentation demonstrate ❑Does Not j 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable i dwelling units must demonstrate compliance with the IECC _ Commercial Provisions. _ 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies ;403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [Pl on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 3 of10 Section plans Verified Field Verified Foundation Inspection i Value Value Complies? Comments/Assumptions &Req;.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interior R_ R ❑Does No table for values. insulation is used, verification t may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F0511 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 40 22 9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. [-]Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system -- ❑Complies [FO12]2 controls installed. ❑Does Not ^ ' ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 - Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 4 of 10 ir Section _ plans Verified ' Field Verified # Framing/Rough-in Inspection; Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- []Complies See the Envelope Assemblies j402.3.4 ❑Does Not table for values. [FR1]1 [-]Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, []Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not o, with the NFRC test procedure or taken from the default table. :[-]Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built _ ❑Complies [FR20]1 is listed and labeled as meeting ., ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 [-]Not Observable or has infiltration rates per NFRC 400 that do not exceed code :❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures,_ ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm leakage at 75 Pa. ;❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where <3 inches. Supply and ❑Not A ervaerva return ducts in other portions of Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. j403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. []Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 5 of 10 Additional Comments/Assumptions: --..—_.--- --— _- -------- - 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 6 of 10 S Section i# Insulation Inspection Plans Verified Field Verified Complies? j Comments/AssumptionsValue Value&Req.ID -- 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. !❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- i❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/� of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior, the exterior insulation E] Mass E] Mass ❑Not Observable requirement applies (FR10). E] Steel E] Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies I[IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ®�� � ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 7 of 10 Section �anV €ied Field Verified& Rq,lp( Final Inspection Provisions Value Complies? ; Comments/Assumptions 1402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 1402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 1402.2.2, 1402.2.6 E] Steel ❑ Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 1303.2 manufacturer's instructions. ❑Does Not 1[F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable ;402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable i- ❑Not Applicable i 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable _ ❑Not Applicable €402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies F[F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies ,[F19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 1403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies 3[FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) —3-Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 8 of 10 Section Plans Verified Field Verified i '& Re IQ Final Inspection Provisions Value Value Complies? Comments/Assumptions 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy [-]Not Observable and airflow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating '❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems m ❑Complies [F128]2 have a circulation pump.The r❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal Intl, for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F12 9]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically f adjust the energy input to the ❑Not Observable heat tracing to maintain they ' `� ❑Not Applicable desired water temperature in the ; ; piping. 403.5.2 Water distribution systems that `;❑Complies [F130]2 have recirculation pumps that :. '❑Does Not pump water from a heated water supply pipe back to the heated " ❑Not Observable water source through a cold i' ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls f that manage operation of the #. pump and limit the temperature # of the water entering the cold water piping to 1044F. � = 403.5.4 Drain water heat recovery units ❑Complies (F131]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat ` ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one c or two showers.Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F1611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage [-]Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value } Value Complies? I Comments/Assumptions & Req.ID _ 401.3 Compliance certificate posted ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for u �❑Complies [F118]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable i ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 01/17/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\28 Wooden Lane.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling EquipmentEfficiency Heating System: Cooling System: Water Heater: Name: Date: Comments D DING&CODE s s � 0(91 0 0 Z a' Z O Q� �23 / PIP--T PLAN 2 J ANCI HAVE PE, N,"'; " REQ THE DISTd FROM 7 'E PRO° (Y LINES TO THE / pRGYC�-- URE(S)OR SIGN S) _ P 2Z r 3` 101 2 Feed d'i�° :.1. / 0 Sq- s oelu 1x660045 Q�res $ 651 ' 55„ W A Vl 3f t6 • RCO Q o ` o o ,1 AGO omen 308"2.1 Grow eN o�2� 440 5 f 61 Mich ooden �a 230 f Gar' 4 5 W o_ SFD PO eferene' de For � Map R ubdivision G ed a S L L Of A Prop pevelopmOn2003 014 Map La)aced' APn' 0 ary 4' 2 s Last Revise��aen & Pkat 6,349 L By; Van h 3, 2014, Filed: Marc; Map Reference LOT 24 Map of a Proposed Subdivision Made for Laric Development,LLC Dated.,April 10,2003 L 100.30' Last Revised.,January 4,2014 R375.00' By. Van Dusan&Steves BN 32015'02" E Filed. March 3,2014,Plat C-349 Chord Length 100.00' LOT 22 Notes: 1.Surveyed parcel is subject to easements,covenants,and agreements of record. t e 29 ll* 2 Surveyed parcel is subject to conditions of the subdivision approval. 4 2 Story Wood Frame -T --- Gas Meter House Electric Meter 0- 4e so. Lands NIF of t Luzerne Holdings, Inc. Lot 21 Area 106600.0! Sq. Feet 2.45t Acres #ro via,`sSa� ' C ' 1 LOT 20 4 0 'F IWO LOT 19 eD ca 0 60 2 n Ok G)Q C= C)s w���� / M Lands NIF of M Luzerne Holdings;in 0z 6 (� _ - cn M — — I� r1Cnirk p S83049'28" W Z 38.97 Cn C Lands NIF of DKC Holdings, Inc. �7 Date: May 2.5, 2018 Du s IMALZM&D ALTERAMON OR ADDITION TO A SURVEY Scale 1"=50' MAP BEMNG A UCVN5CD LAND SURVEYORS SEAL 15 A Map of a Survey made for VIOLATION OF 5Mn0N 7209,WO-DIMION 2,Or THE & NEW YORK 5TAIE EDUCATION LAW.- -ONLY COMM Mom THE OMUAL Or THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS Ste -ves 5M SMALL BE CON510CMD TO BE VAUD TMX Com.' -CMTIFICATION5 INDICATED HEREON SIGNIFY THAT S- 1 THIS SURVEY WA5 PREPARED IN ACCORDANCE 1%FK THE Christopher J. Gravius III =TING CODE Or MAO=FOR LAND SURVEYORS ADOPTED BY THE NEW YORK STATE A550oATION OF FROM5540NAL Land Surveyors LAW 51AMOR1.SAID MMMCA71ONS ViAll RUN ONLY TO THE PCR50N MR WHOM THE SURVEY IS PREPARED.ANDSHEET 1 OF 1 0 Mr BEHALF TO THC TITIX COMPANY,GCUMMENTAL AGIDICY AND LENDI INVATUTION U5TED HEMM.AND Town of Queensbury, Warren County, New York N 169 Haviland Road Queensbury, New York 12804 To IKE A56IGNM'OF THE U!NDING IN5TFWnC".' GRAVIU5 (518) 792-8474 New York Lic. No. 50135 NO. DATE DESCRIPTION DING. NO. e9-241 Lot 21 .1 NACE ENGINEERING, P.C. 169 Haviland Road, e , -1 4,1- Phone-518-745-4410 - 1� JUN 14 2018 TOWN OF QUEENSBURY June 11, 2018 BUILDING&CODES Job#46257 New York State Dept. of Health 2.-C— 0 0 Zoe . ZQ 77 Mohican Street Glens Falls,NY 12801 RE: Burnt Ridge Subdivision Phase 2 - Queensbury(T), Warren County Lot#21 Septic System—28 Wooden Lane Gentlemen: This letter is to inform you that we inspected the completed septic system for the house at 28 Wooden Lane (Lot#21) in the Burnt Ridge Subdivision on 5/30/2018. The septic system as installed was for a 4-bedroom house and consisted of a 1,250 gallon septic tank and 200 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, /27 Thomas R. Center Jr., PE AS BUILT cc: Dave Hatin, Town of Queensbury Eric Wilson, The Michaels Group tr LOT 24 Map Reference: I Map of a Proposed Subdivision Made for Laric Development,LLC L 100.30' Dated:April 10,2003 R375.00' Last Revised:January 4,2014 By:Van Dusan&Steves BN 32°15'02° E I Filed.March 3,2014,Plat C-349 Chord Length 100.00' LOT 22 <' Notes. 1.Surveyed parcel is subject to easements,covenants,and ? 29 1250 GAL. Ire pa ! agreements of recorol x?'. SEPTIC TANK I 2.Surveyed parcel is subject to conditions of the subdivision approval. 4 + i G. ± 4 + I d� 2 5tory Wood Frame E ± s u5e6 I Gas Meter �O 5.5'_ G'O,s. Electric Meter S? 6, I 0 4 I so. ± Lands N/F of DISTRIBUTION BOX I Luzerne Holdings, Inc. ABSORPTION TRENCHES- 4 @ 50' EA. Lot 21 I Area 106600.0± Sq. Feet 2.45± Acres I I i I I � as v- ys I I i LOT 20 !y I I I o I I o I i i tO w I I LOT 19 I m 1 I i I I i 1 I I I I I I I I I Lands N/F of i Luzerne Holdings, Inc. _ S 83049'28° W I O / TriL ruts . =t' ,;.Kra;. / AS BUILT Lands N/F of w,.. DKC Holdings, Inc. I SEPTIC SYSTEM - AS BUILT BY NACE ENGINEERING 1 Date: May 25, 2018 +� Du •UN UTMOR12EDALTERATIONORADDI ION TOASURVEY Scale 1"=50' MAP BEMNG A UCEN5ED LAND 5URVEYORB 5EAL 15 A Map of a Survey made for V1OunoN Or 5EcrIoN 720.9 SUB-IIASION 2,Or TnE & NEW YORK STATE EDUCATION 1xv S te e s 'ONLY COPIVVITH A NORM THE ORIGINN WOF HIS5LV SURVEY YM MARKED SMALL AN ORIGINAL of THE AU s"COME �y SEAJ.SNALL BE CON5IDERCD TO BE VAIID TRUE COMES.*'CE 1\J M15 SURVEY NWAS I'DICATCD IN AC SIGN THATWITH Christopher J. G r a v i u s I I I TW5 SURVEY WAS PREPNtED IN ACCORDANCE WITH THE Land Surveyors DY THE CODE RP STATE AS POC LANASSOCIATION Or FRI T5 ADOPTED D1'THE NEW YDRK STATE ASSOCIATION OP PROPE55>ONK LAND SURVEYORS.SAID CERTIFICATIONS SNAIL RUN 06LY TO THE PERSON FOR W"oM THE SURVEY 15 PREPARED.AND ON I15 WIA F TO mE TRLE COMPANY.GOVERNMENTAL 169 Haviland� Road Queensbury, New York 12804 GTME µAS5DGNEE5IOOP� �„T�,.HEREON.AND Town of Queensbury, Warren County, New York 0 6/11/18 SEPTIC AS BUILT GRAv1U5 (518) 792-8474 New York Lic. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99-241 Lot 21