Loading...
RC-0037-2018 TOWN OF QUEENSBURY i4ii742 Bay Road, Queensbury,NY 12804-5904 (518)761-8201 - rc� Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0037-2018 Date Issued: Friday, June 8, 2018 This is to certify that work requested to be done as shown by Permit Number RC-0037-2018 has been completed. Tax Map Number: 239.8-1-45 Location: 13 TUSCARORA DR Owner: Samuel Lightbody Applicant: William Mason This structure may be occupied as a: Residential Addition (2nd floor) 256 s.f. Deck Addition 32 s.f. By Order of Town Board Cross Ref. Z-AV- 1-2018 and P-SP-1-2018 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0037-2018 Tax Map No: 239.8-1-45 Permission is hereby granted to: Takundewide Management Group Inc. For property located at: 13 TUSCARORA DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Samuel Lightbody Single Family-Addition $100,000.00 Owner Address: PO Box 160771 Total Value $100,000.00 Big Sky,MT 59716 Contractor or Builder's Name/Address Electrical Inspection Agency Takundewide Management Group Inc. PO Box 85 Cleverdale,NY 12820 Plans&Specifications Residential Addition(2nd floor)256 s.f. Deck Addition 32 s.f. Cross Ref.Z-AV- 1-2018 and P-SP-1-2018 $ 250.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,February 13,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town ueen ury;fl P 4Tu*4(eb15—ary 13,2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement c , Office Use Only Al Ei �DII E Ip�4"ONI Permit#: C WN OF QUEEN ti _ Permit Fee: STOWN OF QUEENSBURY 742 Bay Road,Queensbury, BUILDING CURES Invoice#:_j `� P:518-761-8256 www.gueensbury.net Project Location: TV S 0,A K o W, A gj 2,� C L-CNI6-12Op1-L,E,tJ'y Tax Map ID #: 2 3 9. $ - I - 44 S Subdivision Name: W )n A CONTACT INFORMATION: • Applicant: Name(s): L"'s)%-'- t A-&I rni V% S a� Mailing Address, C/S/Z: po goys qo 6oi --r);ousE aq LL0. Ucw"P 1-6.0 Y l -L"s Cell Phone: ( - -1 3) -7 1- 6 G, a9 3 j Land Line: -S'! ) b S 6 9 S 7 3 Email: 131t..% -r-14K"tTJ)a w1 r7 • Primary Owner(s): Name(s): S P1 r"k'Ili& t- 1 C.--►}T$ a fl y Mailing Address, C/S/Z: P o 18 o 54 1 6 D `7 7 0 J3) cam, .S K y . ,r.., -r- S 9 '7 1 G Cell Phone: &4 01.) 6 LI-D Z9 g 4 Land Line: � ) Email: • Contractor(s): Business Name: �'1�-1<�ra D��J�� t� r� 6f-n-y 6 4z.?. Contact Name(s): Mailing Address, C/S/Z: 0 �� Cell Phone:_) Lan dUine: � ) Email: • Architect(s)/Engineer(s): Business Name: ra 3G s t I). tJ Contact Name(s): d`— c- E 9-AS Mailing Address, C/S/Z: o eo>c ,4-7 1- %&:D Sar) fF A-L," , AI Y 1 I-8 39 Cell Phone:�_) T Land Line: S') 8 ) Zo 0 Email:- i r,.') F o (D tJ b r,"fi Q-W 11E S l &r) C� r"7 Contact Person for Building& Code Compliance: a Ar-A t'? J�}5 0PD Cell Phone: �) Land.dine: �) Email: 0 V Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial Residential WORK CLASS: Single-Family Two-Family _Multi-Family(#of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (#of cars ) _Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 3 '2 D ��L� 1st floor: 2nd floor: 2_S� 2nd floor: 3rd floor: 3rd floor: 41h floor: 4th floor: Total square feet: Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ j © O, o 0 0 2. If Commercial project, what is the proposed use: 3. Source of Heat (circle one): Gas Oil Propane Solar Other I_ L 6- -'Y"R1 C Fireplaces need a separate Fuel Burning Appliances & Chimney Application 4. Are there any structures not shown on the plot plan? YES 00xplain: 5. Are there any easements on the property? YES 6. SITE INFORMATION: a. What is the dimensions or acreage of the rcel? b. Is this a corner lot? YES NO c. Will the grade be changed as a result oft a construction? YES d. What is the water source? PRIVATE WELL T1Fo*A ( S s c�tr'�T►o e. Is the parcel on SEWER or a P IVATE SEPTIC stem? Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 f r DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: V) V i 1% s 0_10 SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 r REVIEWED FOR FILE CORY ENERGY CODE COMPLIANCE Page 1 Residential Heat Loss and Heat Gain Calculation 2/12/2018 In accordance with ACCA Manual J Report Prepared By: Meier Supply Co. Inc. For. Samuel&Jeane Lightbody 13 Tuscarora Dr Queensbury, NY Design Conditions: Glens Falls I ndoor. Outdoor: Summer temperature: 68 Summer temperature: 95 Winter temperature: 72 Winter temperature: -20,. Relative humidity: 50 Summer grains of moisture: 93 Daily temperature range: High Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Walls 11,576 0 11,576 .54,907 Glassdoors .6,807 0 6,807 4,613 Infiltration 1,719 1,653 3,372 8,786 People 1,500 1,150 2,650 0 Windows 2,624 0 2,624 2,551 Skylights 1,094 0 1,094 600 Ceilings 64 0 64 .135 Doors 0 0 0 0 Misc 0 0 0 0 Fireplaces 0 0' 0 0 Floors 0 0 0 5,339 Duct 0 0 0 0 Whole House 25,384 2,803 28,187 76,931 (2.5 tons} HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Lcad ca'CIIaaons are est mates only,actual loads may vary due to weather and construction differences. FORM NO.X33-1448 SUBMITTAL SHEET FOR RA13 SERIES 11/2 TO 5 NOMINAL TON [5.28 TO 17.6 kW], EFFICIENCIES UP TO 15.5 SEER/13 EER AIR CONDITIONER JOB NAME SLVY4.`'t.'e., '4 26\-0 �LOCATION- CONTRACTOR �` f't�'� Y�G�C�1 ORDER NO. Ski kla l ENGINEER UNIT MODEL NO.A/11 < 1 SUBMITTED FOR ❑4PPROVAL ❑RECORD COIL MODEL NO., DATE ("Q- _Ct AIR HANDLER MODEL NO. 2 1�S tGtll l� FEATURES FOR RA13 SERIES AIR CONDITIONER UNITS UNIT pATA . New composite base pan-dampens sound,captures louver panels,eliminates COOLING PERFORMANCE corrosion and reduces number of fasteners needed .4 • Powder coat paint system=for a long lasting professional finish EFFICIENCY .................................. SEER + Scroll compressor-uses 70%fewer moving parts for higher efficiency and TOTAL CAPACITY`.................... CGv MBH[kW] increased reliability SENSIBLE CAPACITY'.............. MBH(kW] • Modern cabinet aesthetics-increased curb appeal with visually appealing design OUTDOOR DESIGN TEMP......... C_ _°F[°C].DB • Curved louver panels-provide ultimate coil protection,enhance cabinet strength, and increased cabinet rigidity TEMP.OF AIR ENTERING Optimized fan orifice-optimizes airflow and reduces unit sound EVAPORATOR COIL.............. 'F['C]DB • • Rust resistant screws-confirmed through 1500-hour salt spray testing 'F['C]WB PlusOne'"'Expanded Valve Space-3"-4"-5"service valve space-provides a POWER INPUT REQUIREMENT.......... kW minimum working area of 27-squate inches for easier access (•uses blower motor heat) + PlusOne'll Triple Service Access-.15"wide,industry leading corner service PERFORMANCE access-makes repairs easier and faster.-The two fastener rempivable corner HEATING allows optimal access to i6ternar.unit comp6ne6ts.individual louver panels corfie out once fastener is removed,for faster coil cleaning and easier cabinet reassembly EFFICIENCY............................... HSPF . Diagnostic service window with two-fastener opening-provides access to the high TOTAL CAPACITY`................ .. MBH(kW] and low pressure. OUTDOOR DESIGN TEM ......... 'F I'C]QB External gauge port access-allows easy connect ivn'of"law-loss"gauge ports TEMP.OF AIR ENTE G • Single-row condenser coil-makes unit lighter and allows thorough coil cleaning to EVAPORATOR C IL. 'F['C]DB maintain"out of the box"performance • 35%fewer cabinet fasteners and fastener-free base-allow for faster access to SUPPLY AIR BLOWER •• Internal components•and'hagsle-free panel removal • Service trays-hold fasteners or caps during service calls TOTAL AIR SUPPLY.................. CFM[Us] + OR code-provides technical Information on demand for faster service calls TOTAL RESISTANCE EXTERNAL • Fan motor harness with extra long wires allows unit top to be removed without TO UNIT........................................ IWG disconnecting fan wire. BLOWER SPEED.............................. RPM ACCESSORIES/OPTIONS POWER OUTPUT REQUIREMENT .... BHP Compressor Crankcase Heater............................................................................❑ MOTOR RATING .......................... HP[WJ Low Ambient Control(Model No.RXAD-A08)..............................................................0 POWER INPUT REQUIREMENT kW Compressor Sound Cover............................................................................................ Compressor Hard Start Kit.................................... ❑ ........................................................ ELECTRICAL Classic Top Ca w/label 91-101123-21 Cl POWER SUPPLY.......................... Hz TOTAL UNIT AMPACITY.................. AMPS MINIMUM WIRE SIZE...................... AWG i c..a."r.mwkM�n,wtsceai MAXIMUM OVERCURRENT DEVICE FUSES/HACK BREAKER ............ AMPS (IN CERTAIN MATCHED SYSTEMS) wo u r•n «vr ++o " ,.. . ACCESS SIDE 24'(609.6 mm] .�/ Y@US AIR INLETS 12"[304.8 mm] ABOVE UNIT 60" (1524 mmJ lvl,,,k.,r LISTED �f. iomant is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with REScheck Software Version 4.6.1 Compliance Certificate Project %FEB E Energy Code: 2015 IECC o 9 201Location: Warren County, New York Construction Type: Single-family N OF QUEENSBURY Project Type: New Construction ILDING&CODES Orientation: Unspecified Conditioned Floor Area: 768 ft2 P��® REVIEWED FOR Glazing Area 20% FILE COPY Climate Zone: 6 (8499 HDD) ENERGY CODE COMPLIANCE Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 13 Tuscarora Drive Samuel &Jeanne Lightbody Northern Design Cleverdale, NY 12820 Builder:Takundewide Management Group Inc. n Compliance: 3.3%Better Than Code Maximum UA: 123 Your UA: 119 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Assembly Gross Area Cavity Cont. .or ' Perimeter Wall 1: Wood Frame, 16" o.c. 996 21.0 0.0 0.057 45 Orientation: Unspecified Window 1: Wood Frame:Double Pane with Low-E 201 0.270 54 Orientation: Unspecified Ceiling 1: Cathedral Ceiling 779 49.0 0.0 0.022 17 Skylight 1: Wood Frame:Double Pane with Low-E 6 0.440 3 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Eric Teras - Designer 2-`?, -A is:, Name-Title re Date O F , ��� KEITy, �O _ µ q ,�•,'`\t-�� �` �� Y.. �Gam' % Project Title: Report date: 02/07/18 Page 1 of 9 REScheck Software Version 4.6.1 Inspection Checklist Energy Code: 2015 IECC Requirements: 7.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 Ienergy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Jy; Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods [-]Not Observable _ Btu/hr Btu/hr approved by the code official ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 2 of 9 2015 ICC Foundation Inspection Complies? Comments/Assumptions 303.2.1 A protective covering is installed to ❑Complies [FO11]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below grade. ❑Not Observable' ❑Not Applicable 403.9 "Snow-and ice-melting system controls'❑Complies [FO12]2 installed. ❑Does Not ❑Not Observable'. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 3 of 9 Section Plans Verified field Verified # Framing /Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.61 Not Observable 402.5 I []Not Applicable [FR2]1 303.1.3 U-factors of fenestration products 4 ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.1.1, Skylight U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.3, ❑Does Not table for values. 402.3.6, 402.5 ❑Not Observable [FR5]1 ❑Not Applicable 402.4.1.1 'Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ��. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ; ❑Not Applicable ; 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ` R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 =for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 °F or chilled fluids ❑Does Not below 55 4F are insulated to >_R- *. ❑Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR2411 piping. ❑Does Not ❑Not Observable : ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not []Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 4 of 9 Section Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not j intakes and exhausts. ❑Not Observable []Not Applicable Additional Comments/Assumptions: 1High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact (Tier 3) Project Title: Report date: 02/07/18 Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior, the exterior insulation requirement applies(FR10). E] Steel ❑ Steel ❑Not Applicable 303.2 ;Wall insulation is installed per ❑Complies [IN4]1 =manufacturer's instructions. ❑Does Not ❑Not Observable I ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 6 of 9 t Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 ❑ [FIM Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 `Blown insulation marked every ❑Not Observable 300 ft . ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent []Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI311 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable []Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 "ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable " ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 []Complies [F1411 cfm/100 ft2 across the system or ft2 ft2 []Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable ;tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test: Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 'Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable []Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value' Value Complies? Comments/Assumptions &Re .ID 403.6.1All mechanical ventilation system []Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2i through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ' []Not Observable return pipe or a cold water supply pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically 'adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 'Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold 'water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat []Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F12313 no continuous pilot light. ❑Does Not []Not Observable ❑Not Applicable 1 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 02/07/18 Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.1D 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F[18]3 mechanical and water heating ❑Does Not systems have been provided. '❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 02/07/18 Page 9 of 9