Loading...
AST-0365-2018 i TOWN„ow OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: AST-0365-2018 Date Issued: Tuesday, November 27, 2018 This is to certify that work requested to be done as shown by Permit Number AST-0365-2018 has been completed. Tax Map Number: 296.16-1-7 Location: 199 MEADOWBROOK RD Owner: Wayne Szucs, Valerie Szucs Applicant: Red's on the Ground Services This structure may be occupied as a: 3-season porch 196 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the rista,„0 4 ...:i property owner of the responsibility for compliance with Site Plan, f Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 4 y - ,, TOWN*OF QUEENSBURY $1, 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 4 \- -. ..d, Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: AST-0365-2018 Tax Map No: 296.16-1-7 Permission is hereby granted to: Red's on the Ground Services For property located at: 199 MEADOWBROOK RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction• Owner Name: Wayne Szucs Porch-3 Season,Covered,Enclosed $19,400.00 Owner Address: 199 Meadowbrook RD Total Value $19,400.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Red's on the Ground Services 54 McCrea ST Fort Edward,NY 12828 Plans&Specifications 3-season porch 196 s.f. $ 125.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,July 13,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ueens 4ridi1i" _-,.. 018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement ;- 1 v6 4 Office Use Only 4.00,,,r— ,, Try ACCESSORY STRUCTURE Permit#: A C 'i-b 3( j -7-0 _ PERMIT APPLICAT E C E Q Ur Et ee: $ li 25-, Town of Queensbury 742 Bay Road,Queensbury,NY 12804 Invoke 0 � P:518-761-8256 www.queensbury.net JUN 18 2n1Q 1 Li I Project Location: i4f ilea"s ,•ao� gd TOWN OF 4UEENSBURY � BUILDING&CODES .Tax Map ID #: ' 'ttc, ).L` ( `'--7 Subdivision Name: CONTACT INFORMATION: • Applicant: Mailing Address, C/S/Z: / 99' ine,0 >,91;. k gel. ai.e,�,s 6Yy,Aiti1 i-f /2.EC f Cell Phone: ( 8(93 ) 7i7"7T70 Land Line: ( ) Email: • Primary Owner(s): Name(s): . Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: • Contractor(s): Business Name: rya-cAs Oi A-tpita c..,.,„i-er Contact Name(s): et d.r'evv/ee M ,,,,.,ka. Mailing Address, C/S/Z: 91 Me- s't• # 2 r~ -I- t d uotu-d, it).V/. i 2-$z 8 Cell Phone: ( 51 9 ) 22'7— 7(th 7 Land Line: ( ) Email: MIreoee ►-70ila_i>/.i, �,gr oo, Eom • Architect(s)/Engineer(s): Business Name: ,114 Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: Contact Person for Building & Code Compliance: ehrence ® ,a Aow Cell Phone: ( 570 ) 22-z- -74'd 7 Land Line: ( ) Email: e/arence in ayJaiic m @ pilot• evoi Town of Queensbury Building&Code Enforcement Accessory Structure Application Revised April 2017 PROJECT INFORMATION: TYPE: Commercial / Residential . WORK CLASS: Deck,Open Porch Solar Panels(w/o rafter upgrades) Carport _Cell Tower Shed Pavilion, Pole Barn, Canopy Dock _Gazebo Detached Garage _Boathouse(with or w/o sundeck) / 3-Season Porch Other(description: SQUARE FOOTAGE OF STRUCTURE: 1st floor: f 16 2nd floor: Total square feet: / 4' ADDITIONAL PROJECT INFORMATION: od 1. Estimated Cost of Construction:$ /g e/B�• 2. If Commercial project,what is the proposed use: 3. Are there any structures not shown on the plot plan? YES ISO Explain: 4. Are there any easements on the property? YES DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: G4 rB,ice lde4et...�, SIGNATURE: {/��- DATE: 00/9 Town of Queensbury Building&Code Enforcement Accessory Structure Application Revised April 2017 INSPECTION WORKSHEET (BINS-005532-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: AST-0365-2018 08/01/2018 John O'Brien Permit Failed Building Insulation Job Address:Parcel Number:199 MEADOWBROOK RD Queensbury, NY 12804 296.16-1-7 Contact Type Company Name Name Primary Owner Szucs, Wayne Applicant Red's on the Ground Services , Contractor Red's on the Ground Services , Granted Permission Red's on the Ground Services , Primary Owner Szucs, Valerie Checklist Item Passed Comments Building Inspector Notes NO 8/1/18 Insulation Not Approved -Floor Insulation vapor barrier needs to be flipped to underside of floor. -Fill all gaps in insulation in wall and ceiling insulation. -Taped all breaks in wall and ceiling vapor barrier. -Remove fiberglass insulation from perimeter of windows and install window & door spray foam. -Seal exterior bottom plate with caulk at floor. Window Sealing NO U Factors = .3 cfm for windows, .5 cfm for doors NO Tyvek or Similar Exterior Sealant NO Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check NO 8/1/18 Insulation Not Approved -Floor Insulation vapor barrier needs to be flipped to underside of floor. -Fill all gaps in insulation in wall and ceiling insulation. -Taped all breaks in wall and ceiling vapor barrier. -Remove fiberglass insulation from perimeter of windows and install window & door spray foam. -Seal exterior bottom plate with caulk at floor. Blower Door Test NO Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Door / Window Sealed (No Insulation)NO Tub Shower R-20 with Vapor Barrier NO Air Barrier behind Knee Walls NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO Aug 01, 2018 Page (1) INSPECTION WORKSHEET (BINS-005532-2018) Checklist Item Passed Comments All Return Air Hard Duct Work NO House Wrap Taped at all Seams NO Aug 01, 2018 Page (2) O'Brien, John (Inspector) REVIEWEn FOR NOTICE aiLag O O ...mil NCE J FOAM INSULATION MUST BE C E COVERED BY A 15 MINUTE 1296.16-1-7 AST-0365-2018 THERMAL BARRIER22 s Szucs, Wayne & Valerie 199 Meadowbrook Road - 3-season porch 199 s.f. NOTICE % TPA.-PRN._ 1 • i0 'exi FILE COPY MUST BE COVERED BY `� Iw' 1-COMBUSTIBLE BARRIE MI d*-+aKU aN — so o o Q • : j : ____d ....3 1 C a V •-+KLI 7 CN mil I �^'^- c C2----- .- VD TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination,compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of S30o0'8'ONIO1Ifl8 New York State. AAf18SN33flb Bo NMol 8 OZ TOWN OF QU fiRriY- - I � � Nnr I BUILDING & rQ` P '& t1 Reviewed By. I ' . Date: , _ r1 .` existing door to be removed opening -to be finished with drywall fr.. %.'• i ' I .. r.... windqwschedute name size quantity LI 13 A 48x60 twin Double hung 1 14' (& Light. and vent 189SF room required light actual required vent actual 1 15.12SF 110SF 7,6SF 55SF 41-3" 1=1 I:=] 4`-3il A 1 /I ar-72- 2J-721, ® ® ® Ph 0 D --.... 2,-701" I. 4' 2"---- --4' 2" ...-- 2' 721 " --, L - loor D ( an Continuous ridge vent asphalt shingles 151* roof Felt or synthetic underlayment ro er vent u entire roof Ts— ri-Aka 12 • 4' 0.C. vente31 soffit Hurricane clips or 6' timberlok's (3) ax10 header ex6 Studs 16' Q.C. R-21 Insulation House Wrap osb sub floor 2x10 floor Ioists 16' O.C, • , ' treated plywood under Joists / grade bear4 6x6 posts 12' poured concrete pier 48' below grad,e/ fi SI , 3 )(14 Section View -0 s .-A---. ---- 14.- 110'-'1111.111-1..tik ......s ........ '‘ c_.% ---. , mk .,.........10) 6 c 1) 0100010 ' REScheck Software Version 4.6.5 Compliance Certificate © E - t) JUN 2g2 8 Project Szucs Sun Room TOWN OF CUEENSBURY COMMUNITY DEVELOPMENT Energy Code: 2015 IECC Location: Glens Falls, New York Construction Type: Single-family Project Type: Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 199 meadow brook rd. Wayne Szucs Stephen Hitchcock Queensbury,NY 12804 199 meadowbrook Rd 8 Frank Street Queensbury,NY 12804 Fort Edward,NY 12828 518-365-2962 Compliance: Passes using UA trade-off Compliance: 10.1%-Better Than Code Maximum UA: 69 Your UA: 62 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Wall 1:Wood Frame,16"o.c. 333 21.0 0.0 0.057 10 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 1 copy 7:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.280 4 Window 9:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.290 3 Door 1:Solid 20 0.290 6 Floor 1:All-Wood Joist/Truss:Over Outside Air 192 30.0 0.0 0.033 6 Ceiling 1:Cathedral Ceiling 192 38.0 0.0 0.027 5 • Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 1 of10 - .- .r Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in th EScheck Inspection Checklist. REVIEWED BY //Z`7/1f3 Name Title . PETER JENSEN Ligna e Date Project Notes: 17 WEST ROAD Designer SOUTH GLENS FALLS NEW YORK 12803 �Si`E® AA04,� (518) 798-3859 ' •5. 1ER .>•,� 4.1 • Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 2 of10 s ; ciREScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, Construction drawings and ;DComplies 103.2 documentation demonstrate ODoes Not (PR1)1 energy code compliance for the 4building envelope.Thermal 1:1Not Observable envelope represented on ONot Applicable 'construction documents. 103.1, °Construction drawings and ;:Complies 103.2, documentation demonstrate iCJDoes Not 403.7 energy code compliance for [PR3]1 'lighting and mechanical systems. ; DNot Observable :4 Systems serving multiple ONot Applicable dwelling units must demonstrate :compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ;CiComplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ;EiDoes Not [PR2]2 ;on loads calculated per ACCA Cooling: Cooling: ;LNot Observable .)y, i Manual J or other methods Btu/hr ; Btu/hr approved by the code official. _ 'C7Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 3 of10 r • Section # Foundation Inspection Complies? Comments/Assumptions &Req.ID 303.2.1 A protective covering is installed to 'CIComplies [FO11]2 protect exposed exterior insulation []Does Not 'and extends a minimum of 6 in.below grade. DNot Observable ;[]Not Applicable 403.9 Snow-and ice-melting system controlsOComplies [FO12]2 installed. !DDoes Not t'' DNot Observable; 'DNot Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.11, 'Door U-factor. U- U- ❑Complies ;See the Envelope Assemblies - 402.3.4 ❑Does Not table for values. [FR1]1 `❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). !❑Does Not ;table for values. 402.3.3, p 402.5 r '❑Not Observable [FR2]1 °❑Not Applicable 303.1.3 ;U-factors of fenestration products' +❑Complies [FR4]1 are determined in accordance Does Not with the NFRC test procedure or ;taken from the default table. QNot Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not g instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ;❑Does Not AAMA/WDMA/CSA 101/1.S.2/A440 ❑Not Observable s or has infiltration rates per NFRC 400 that do not exceed code ;❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ElComplies [FR16]2 sealed at housing/interior finish ❑Does Not ;and labeled to indicate s2.0 cfm leakage at 75 Pa. Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics OComplies [FR12]1 insulated>=R-8 where duct is ,❑Does Not '4 >=3 inches in diameter and>= R-6 where<3 inches.Supply and QNot Observable =return ducts in other portions of ❑Not Applicable :the building insulated>= R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as ; ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable QNot Applicable 403.4 ;HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- ,❑Not Observable ❑Not Applicable 403.4.1 ,Protection of insulation on HVAC ❑Complies [FR24]1 piping. j ❑Does Not {j ;❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 .?_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers are] ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable i❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 5 of10 ♦ ♦ t 1 High impact(Tier 1) 2 Medium Impact(Tier 2) f 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 6 of10 ♦Y F t • Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ;DComplies [IN13]2 ;or the installed R-values inDoes Not provided. iDNot Observable DNot Applicable 402.1.1, Floor insulation R-value. R- R- DComplies See the Envelope Assemblies 402.2.6 El Wood ❑ Wood '.DDoes Not table for values. [INl]1 Steel ❑ Steel 9.,j ;DNot Observable ONot Applicable 303.2, Floor insulation installed per `OComplies 402.2.7 manufacturer's instructions and DDoes Not [IN2]1 in substantial contact with the j i underside of the subfloor,or floor' DNot Observable i framing cavity insulation is in DNot Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the ;top of all perimeter floor framing ;members. 402.1.1, Wall insulation R-value. If this is a; R- R- OComplies See the Envelope Assemblies 402.2.5, j mass wall with at least 1M of the ;0 Wood 0 Wood 'ODoes Not table for values. 402.2.E wall insulation on the wall 1 0 Mass i ❑ Mass DNot Observable [IN3]1 exterior,the exterior insulation ;requirement applies(FR10). 0 Steel ;❑ Steel DNot Applicable 303.2 Wall insulation is installed per DComplies [IN4]1 manufacturer's instructions. ;DDoes Not !DNot Observable DNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ;❑Complies See the Envelope Assemblies 402.2.1, '❑ Wood ❑ Wood ❑Does Not :table for values. 402.2.2, 402.2.E '0 Steel ElSteel I]Not Observable [FI1]1 's❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. '❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ,❑Complies [FI22]2 i insulation include baffle adjacent 10Does Not 'to soffit and eave vents that extends over insulation. :[7Not Observable I ;C:Not Applicable 402.2.4 :Attic access hatch and door R- R- ❑Complies [F13]1 l insulation?...R-value of the :❑Does Not adjacent assembly. ❑Not Observable E❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa.<=5 ACH 50= ACH 50= ;❑Complies [F117]1 ach in Climate Zones 1-2,and iODoes Not <=3 ach in Climate Zones 3-8. ;❑Not Observable i❑Not Applicable 403.3.4 l Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [FI4]1 f cfm/100 ft2 across the system or ft2 ft2 ;❑Does Not <=3 cfm/100 ft2 without air ;handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ;❑Not Applicable ;occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 iC1Complies [FI27]1 ,determine air leakage with ft2 ft2 [:::Does Not either:Rough-in test:Total !leakage measured with a ❑Not Observable ;pressure differential of 0.1 inch '❑Not Applicable w.g.across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total ,leakage measured with a `pressure differential of 0.1 inch ° w.g.across the entire system including the manufacturer's air ; handler enclosure. 403.3.2.1 Air handler leakage designated f❑Complies [FI24]1 'by manufacturer at<=2%of ;❑Does Not design air flow. []Not Observable '. ❑Not Applicable 403.1.1 Programmable thermostats '❑Complies [Fl9]2 installed for control of primary i❑Does Not ;heating and cooling systems and i initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed iDComplies [FI10]2 on heat pumps. i❑Does Not ;❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water DComplies [F111]2 systems have automatic or l❑Does Not {accessible manual controls. IDNot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 8 of10 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 403.6.1 All mechanical ventilation system j ;DComplies [FI25]2 'fans not part of tested and listed ' iDDoes Not HVAC equipment meet efficacy !and air flow limits. ;❑Not Observable I !❑Not Applicable 403.2 Hot water boilers supplying heat i ❑Complies [FI26]2 through one-or two-pipe heating ; ❑Does Not ;systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor i ❑Not Applicable . temperature. 403.5.1.1 !Heated water circulation systems ;❑Complies [F128]2 !have a circulation pump.The ;❑Does Not system return pipe is a dedicated 1 ,return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ;❑Not Applicable syphon circulation systems are - not present.Controls for circulating hot water system pumps start the pump with signal :for hot water demand within the occupancy.Controls automatically turn off the pump :when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 ,Electric heat trace systems {❑Complies [FI29]2 ;comply with IEEE 515.1 or UL i iElDoes Not 515.Controls automatically adjust the energy input to the :DNot Observable heat tracing to maintain the j❑Not Applicable desired water temperature in the piping. 403.5.2 !Water distribution systems that ❑Complies [FI30]2 !have recirculation pumps that j❑Does Not I pump water from a heated water 'supply pipe back to the heated ;❑Not Observable water source through a cold ❑Not Applicable :water supply pipe have a ;demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1042F. 403.5.4 Drain water heat recovery units ;❑Complies [FI3132 tested in accordance with CSA ;❑Does Not B55.1. Potable water-side pressure loss of drain water heat `❑Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to ,three or more showers. 404.1 75%of lamps in permanent ;❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have i❑Complies [F123]3 'no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 401.3 :Compliance certificate posted. 'OComplies [FI7]2 'ODoes Not i 9 ONot Observable ONot Applicable 303.3 Manufacturer manuals for OComplies [F118]3 !mechanical and water heating ODoes Not systems have been provided. 'DNot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Szucs Sun Room Report date: 06/25/18 Data filename: C:\Users\Steve\Documents\REScheck\reds sun room rescheck.rck Page 10 of10 T °r T m d a i20 IE Energy CI Efficie15ncyCC Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling/Roof 38.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.28 Door 0.29 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments L- • • • NW, INtikte.- - - OD EC EllV/ ED DIAN] ainivNeis 18 2818 , u0(s)ainioneasa]sodo&I .-.- H.L 01 N11 Al2:12dOZ:Icl BR.1. 1/110 :1.d TOWN OF QUEENSBURY 33NVISIC.1-31-1.1.a3nsvm ATIVNOS63d 3AVH I BUILDING&CODES 1.4 VI _LWIT7-1,11 ----AW d • • .. . . . , • I . .. .. ., . , . 1 . i . . 49 i • . . . .! .. . . . . . -----._ t . PILE COP . . ,I.1„...__„ : .. _. ii . ,. , i. . . . . . A .v ' . .. • • . Deo f . . 0 • ?r9 4;1-1 e i . . . . . . . .it to e ' . (IN H ..:. , v ,t‘ ,...„ • . . • , , c• ---.7 •i . , . . . ,•• • , - • :,,,,,•_......._?,,,,, "t ,,,,.11-1,,„„,.._ .._,_ -..,-'.•,,f r" 1 1 ....--......7",,, , ! 1 1 . •tie ii 54' '. .. • . , .. . ,: . .• . . .. . 1 ..., , . i ..- . : . . .: . ; ,, ! . , . . 0 i • . ... .. ,..... . 7 .. _____ ---- 7‹. / ...,.... ... i . . it " -...-------,..,.....,,.—...,..e. •,.,,,:,!!••, 1.=,:i I.ili'..'.?;y 44,7::-.21.:7,fterf.t.';_...;,Z.a_________1.4:s7n...1_,;-1.-.or kooy„.. evai„,„ ,zi4 c.s -, -7:-..9,,,. • • -v .,„... .„..k.....4.L.,-:•-.,,,„ .. --.1 i...- - , ......._.........__.. . . . . . . 0 04110 e C7,f) 1)a_(o•vrt.,42. S2-4J' t 7_ i (I Get do ll) t)tr.o--0 . 4i..f (12 4- lio , •,- Zi ° • "1 1 C ia_v-e-fe,cr— (A-44.A. . /g - -2.2 -z- 74,6 7 . 4 4, I , • . . . • ..... . . ,:-.•.. 1--- , • _a ..... . . 1 , 1-........~.....«.-......... . , ..; e . yo,,;;,: coi:=-: QUE.ENZ.53URY I* -,-.. '- '"0 -.1, a", 1,11:zi.;Mtj ,7 DEVELOPMENT ., • -. i ....- . . . . . , . • -.-- \ . . • •. • • - q c•S' “ f'.."--> 0 . 112_ • • HAVE PERSONALLY MEASURED THE DISTANCE FROM THE PROPERTY Li WES TO THE - . • PROPOSED STRUCTURE(S)OR SIGN(S) . _....., — i 7 / 7...e.:=1;/.1,..-_-/-7.!........L is!‘ATURE DAVE. . , . 1 . — - --r, 7--- . • il .?....—Ss : . . f • . . .... . ......— _ . . _ . ..... , ,. . .— ..... . . .. c .^ .._-. _.— ... . .