Loading...
2009-105 - TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 I F I IN]. AT:E OJ r' 0 CCU P-A►NCY Pemut Number. P20090105 Date Issued: Friday, May 28, 2010 This is to certify that work requested to be done as shown by Permit Number P20090105 has been completed. Location: 35 FITZGERALD Rd Tax Map Number. 523400-289-018-0001-025-000-0000 Owner. DAVID & GAY JARVIS Applicant: DAVID & GAY JARVIS This structure may be occupied as a: Garage Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals, TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090105 Application Number. A20090105 Tax Map No: 523400-289-018-0001-025-000-0000 Permission is hereby granted to: DAVID &GAY JARVIS For property located at: 35 FITZGERALD Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DAVID & GAY JARVIS 1 SUSAN PI Garage Detached $16,000.00 QUEENSBURY, NY 12804-0000 Total value $16,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-105 832 sq ft detached garage $83.20 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,April 28,2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Que bury; T esday,April 28,2009 ZZSIGNED BY for the Town of Queensbury. Director of Building&Co e Enforcement OFFICE USE ONLY , , , _ , , 00 TAX MAP NO. ERMIT f FEE OD PPROVAL ' , , , , , ACC SSORY UCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: �z '�' if/Y L l //i%�� INSTALLER/BUILDER: 12a" '� l " ADDRESS:- >,�� i�Lci/e��a�� /S� ��7 ,/�y ADDRESS:--35 PHONE NOS. �ts D��- G 1 PHONE NOS. ?� 3 f�S 2 9-0 LOCATION OF PROPERTY:,Kfi efCA4 len (Lk yyS7UBDIVISSIION NAME: ✓"�y� LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES LT NO IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: // ESTIMATED COST OF CONSTRUCTION: $!�� ANY 0-'.1ER ACCESSORY STRUCTURES ON PROPERTY? /V LS IF YES,PLEASE LIST: ll CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: t, 1--" PHONE: PROPOSED CONSTRUCTION 1sT ND PROPOSED FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT SQ.FT. SO.FT. FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH' BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: Y l0 OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall e k—;+ .. ;— +_. ., h...-+7F7....a,. , r r%--. . -- r._s:r:--`- -r 1+-_-_1t---- '--—-- .-- - -. . Queensbury Building & Code Enforcement - Residential F1 I In coon i� A Office No. (518)761-8256 Arrive: Date Inspection request received: Inspector's Initi NAME: 1 P M #: LOCATION: k-krT D TYPE OF STRUCTURE: � f�C�mments• N (�' e Number Address visible from road C himnmney Height!"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 8 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks atios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deckporches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 8 inches with 10 feet 8 inch clearance to sill plate Gas Valve shut-off a osed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 38 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Bette backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 sq.ft.vents Bathroom Fans f no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc fault Breaker in Bedrooms Flex Gas Pipe Bondin As Built Septic System/Sewer Dept. Inspection Sticker ite Plan./Variance required �urr Okay to issue C I C or C 10 Temporary/PermaneM L:\Building&Codes Forms\Building&Codes\Inspection FormsWesidenfial Final Inspection Forrn_revised 100405.doc;Revised January 7,2008;Revised 8/28/08 To: Job Number: J091233 Curtis Queensbury Project: Jarvis 460 Big Bay Rd Salesperson: *Tim Burke Saratoga LIuIrnber Traders, Inc. Designer: Lucas Ahl Queensbury,NY 12804 Quote Number: B091233 831 Route 67 • Building No. 46 P.O.Number: 0907-Q30206 Ballston Spa - NY - 12020 Deliver To: PRODUCTION DATE 07/22/09 (518) 885-01.94 • (518) 885-1041 F- Page: I Queensbury,NY Date: 07/08/09 13:56:02 MODEL: TAG: LOT# SUBDIV: DELIVERY INSTRUCTIONS: SPECIAL INSTRUCTIONS: Profile: Qty: Truss Id: Span: Truss Type: Top Pit. LOH ROH Load By: Height Bot.Pit. 6.00 15 R1 25-10-08 07-02-04 01--— 148 Ibs.each 2X6 2X6 ATI2 6.00 2 R2 25-10-08 07-02 ON 01-00-00 148 Ibs.each 2X6 2X4 AT12 4.94 1 R3 32-00-00 07-02-04 01-00-00 01-00-00 139 lbs.each 2X4 2X4 TR SBCA BRACING INSTRUCTIONS STAMPED ENGINEERED CERTIFICATE THE ABOVE LISTED ITEMS HAVE BEEN RECEIVED IN GOOD CONDITION.(EXCEPTIONS NOTED) RECEIVED BY: DATE: THANK YOU FOR YOUR BUSINESS. TOTAL WEIGHT 2,655 To: Job Number: J091233 Curtis Queensbury Project: Jarvis 460 Big Bay Rd Salesperson: *Tim Burke Saratoga Lumber Traders, Inc. Queensbury,NY 12804 Designer: Lucas Ahl Quote Number: B091233 831 Route 67 . Building NO. 46 P.O.Number: 0907-Q30206 Ballston Spa • NY - 12020 Deliver TO: PRODUCTION DATE 07/22/09 (5.18) 885-0194 - (518) 885-10411- Page: 1 Queensbury,NY Date: 07/08/09 13:56:02 MODEL: TAG: LOT# SUBDIV: DELIVERY INSTRUCTIONS: SPECIAL INSTRUCTIONS: Profile: Qty: Truss Id: Span: Truss Type: Top Pit. LOH ROH Load By: Height Bot.Pit. 6.00 15 RI 25-10-08 07-02-04 01_00-oo / 148 Ibs.each 2X6 2X6 ATI2 6.00 2 R2 25-10-08 07-02 oa o1-00-00 148 lbs.each 2X6 2X4 AT12 4.94 1 R3 32-00-00 07-02-04 01-00-00 01-00-00 139 lbs.each � 2X4 2X4 TR SBCA BRACING INSTRUCTIONS STAMPED ENGINEERED CERTIFICATE THE ABOVE LISTED ITEMS HAVE BEEN RECEIVED IN GOOD CONDITION. (EXCEPTIONS NOTED) RECEIVED BY: DATE: THANK YOU FOR YOUR BUSINESS. TOTAL WEIGHT 2,655